Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 78
Filtrar
1.
Heart Rhythm ; 2024 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-39236992

RESUMO

BACKGROUND: The influence of hemodynamic parameters on the recurrence of atrial fibrillation (AF) after catheter ablation is not well known, and it remains unclear whether a nomogram combining risk factors and hemodynamic parameters improves prediction accuracy. OBJECTIVE: This study aimed to develop a nomogram on the basis of echocardiographic hemodynamic parameters for predicting AF recurrence after catheter ablation in nonvalvular atrial fibrillation (NVAF). METHODS: A total of 380 consecutive patients with NVAF undergoing AF catheter ablation treatment were prospectively included. Patients were divided into training and validation cohorts in a 7:3 ratio. The follow-up duration averaged 9 months with a median of 12 months, during which 132 patients (34.7%) experienced a recurrence of AF. RESULTS: Least absolute shrinkage and selection operator regression and Cox regression analyses identified 4 significant predictors of AF recurrence: persistent AF (hazard ratio [HR] 1.63; 95% confidence interval [CI] 1.02-2.61; P = .041), systolic/diastolic ratio (HR 0.50; 95% CI 0.30-0.84; P = .009), left atrial acceleration factor α (HR 1.31; 95% CI 1.02-1.68; P = .032), and left atrial appendage peak emptying flow velocity (HR 0.98; 95% CI 0.97-0.99; P = .004). On the basis of these 4 variables, a predictive nomogram was constructed. The nomogram demonstrated C indices of 0.664 and 0.728 for predicting 1- and 2-year AF recurrence, respectively, in the validation cohort. The Kaplan-Meier survival analysis indicated that a Nomo score of >128 was associated with a higher risk of AF recurrence. CONCLUSION: Hemodynamic parameters may offer valuable insight in predicting AF recurrence after catheter ablation. Our study successfully developed a reliable nomogram on the basis of echocardiographic hemodynamic parameters to estimate the risk of AF recurrence after catheter ablation in patients with NVAF.

2.
BMC Med Inform Decis Mak ; 24(1): 225, 2024 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-39118118

RESUMO

BACKGROUND: Despite improvement in treatment strategies for atrial fibrillation (AF), a significant proportion of patients still experience recurrence after ablation. This study aims to propose a novel algorithm based on Transformer using surface electrocardiogram (ECG) signals and clinical features can predict AF recurrence. METHODS: Between October 2018 to December 2021, patients who underwent index radiofrequency ablation for AF with at least one standard 10-second surface ECG during sinus rhythm were enrolled. An end-to-end deep learning framework based on Transformer and a fusion module was used to predict AF recurrence using ECG and clinical features. Model performance was evaluated using areas under the receiver operating characteristic curve (AUROC), sensitivity, specificity, accuracy and F1-score. RESULTS: A total of 920 patients (median age 61 [IQR 14] years, 66.3% male) were included. After a median follow-up of 24 months, 253 patients (27.5%) experienced AF recurrence. A single deep learning enabled ECG signals identified AF recurrence with an AUROC of 0.769, sensitivity of 75.5%, specificity of 61.1%, F1 score of 55.6% and overall accuracy of 65.2%. Combining ECG signals and clinical features increased the AUROC to 0.899, sensitivity to 81.1%, specificity to 81.7%, F1 score to 71.7%, and overall accuracy to 81.5%. CONCLUSIONS: The Transformer algorithm demonstrated excellent performance in predicting AF recurrence. Integrating ECG and clinical features enhanced the models' performance and may help identify patients at low risk for AF recurrence after index ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Aprendizado Profundo , Eletrocardiografia , Recidiva , Humanos , Fibrilação Atrial/cirurgia , Masculino , Feminino , Pessoa de Meia-Idade , Idoso
3.
Artigo em Inglês | MEDLINE | ID: mdl-39105682

RESUMO

BACKGROUND: Global longitudinal strain (GLS) and atrial voltage are acknowledged markers for worse rhythm outcome after ablation of persistent atrial fibrillation (PeAF). The majority of research efforts have been directed towards the left atrium (LA), with relatively fewer studies focusing on the right atrium (RA). The aim of this study was to investigate the effect of the biatrial substrate on the outcome following radiofrequency catheter ablation (RFCA). METHODS: All patients underwent two-dimensional speckle tracking echocardiography (2D-STE) and high-density mapping (HDM) on LA and RA in preoperative and postoperative stages of RFCA. Atrial substrate was assessed by GLS, average voltage, and low voltage zone (LVZ). RESULTS: This retrospective study enrolled 48 patients. With a follow-up of 385.98 ± 161.78 days, 22.92% (11/48) of all patients had AF recurrence and 63.64% in low strain group. Left atrial-low voltage zone (LA-LVZ) prior to RFCA was 67.52 ± 15.27% and 54.21 ± 20.07%, respectively, in the recurrence group and non-recurrence group. Multivariate regression analysis showed that preoperative LA-GLS (OR 0.047, 95%CI 0.002-0.941, p = .046) was independent predictors of AF recurrence. Biatrial average voltage in preoperative and postoperative stages were positively correlated (preoperative: r = 0.563 p < .001; postoperative: r = 0.464 p = .002). There was no significant difference in the proportion of RA in the recurrence group except the septum in preoperative and postoperative stages. CONCLUSIONS: Low LA-GLS and high LA-LVZ may be predictors of RFCA recurrence in PeAF patients. Biatrial average voltage were positively correlated in preoperative and postoperative stages.

4.
Heart Rhythm ; 2024 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-39147302

RESUMO

BACKGROUND: Ischemic heart disease (IHD) has been linked to an increased risk of atrial fibrillation (AF). However, data are sparse regarding the role of IHD in AF recurrence after catheter ablation. OBJECTIVE: We sought to investigate whether preexisting or new-onset IHD is associated with a greater risk of AF recurrence after ablation. METHODS: With use of Danish nationwide registries, all patients undergoing first-time AF ablation in Denmark from 2010 to 2020 were identified. The primary outcome was AF recurrence defined by AF-related hospital admission or antiarrhythmic drug use within 1 year after ablation excluding a 3-month blanking period. IHD was defined as an International Classification of Diseases, Tenth Revision diagnosis of IHD or prior coronary revascularization. RESULTS: Of 12,162 patients undergoing first-time ablation for AF (mean age, 62 years; 30% female), 20% had preexisting IHD. Preexisting IHD was associated with an increased risk of AF recurrence in univariable log-binomial logistic regression (relative risk, 1.09; 95% CI, 1.04-1.14; P < .001). However, after multivariable adjustment including procedural year, preexisting IHD was no longer associated with an increased risk of AF recurrence (relative risk, 1.02; 95% CI, 0.97-1.06; P = .42). In a nested case-control study of those without preexisting IHD before ablation (n = 9778), newly diagnosed IHD after ablation was associated with an increased risk of AF recurrence in multivariable analysis (hazard ratio, 3.03; 95% CI, 1.84-4.99; P < .001). CONCLUSION: The presence of IHD does not appear to reduce the effectiveness of AF ablation procedures. However, the emergence of IHD after AF ablation may serve as a trigger for AF that is insufficiently suppressed by prior ablation.

5.
Heliyon ; 10(12): e32874, 2024 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-38988509

RESUMO

Catheter ablation has been demonstrated to reduce atrial fibrillation (AF) recurrence. The mechanisms of AF recurrence after catheter ablation are unknown, and the present study aimed to identify serum proteins associated with AF recurrence. The present prospective study comprised a cohort of patients with AF, which was divided into two groups after one-year follow-up: group 1 included patients with compensated AF after catheter ablation and group 2 included patients with AF recurrence after catheter ablation. Initial microarray profiling of the serum proteins was performed in small subgroups M1 and M2 recruited from groups 1 and 2, respectively, by an antibody microarray to evaluate potentially relevant proteins. The data of initial proteomic profiling identified candidate proteins in groups 1 and 2, and their levels were then measured by ELISA. The data of profiling suggested an overall increase in the levels of RAD51 and p63 proteins in the M2 subgroup versus that in the M1 subgroup, indicating potential relevance of these two proteins to AF recurrence. The results of ELISA of the levels of RAD51 and p63 in the groups 1 and 2 demonstrated an increase in the levels of RAD51 (11.11 ± 4.36 vs 8.45 ± 4.85 ng/mL; P = 0.009) and p63 (165.73 ± 113.75 vs 100.05 ± 37.56 units of normalized optical density; P = 0.0007) in the group 2 (with AF recurrence or substrate AF) compared with that in the group 1 (compensated AF). Thus, RAD51 and p63 were associated with AF recurrence after catheter ablation and may represent possible etiological factors for subsequent outcomes.

6.
Rev Cardiovasc Med ; 25(3): 81, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-39076956

RESUMO

Atrial fibrillation (AF) is a common disease and is effectively managed through catheter ablation (CA). However, post-ablation AF recurrence can compromise patient outcomes, making the identification of associated risk factors crucially important. Factors influencing poor clinical outcomes include age, female sex, body mass index (BMI), non-paroxysmal AF, and comorbidities including diabetes mellitus (DM) and obstructive sleep apnea (OSA). Furthermore, the selected ablation strategy and employed technology are pivotal to long-term success in maintaining sinus rhythm control. The mechanisms of AF recurrence are complex and multifactorial; no single predictor is definitive. Thus, a personalized assessment of each patient should be tailored to the individual situation. A high risk of relapse does not preclude the option of ablation therapy, but rather underscores the necessity to address and manage underlying conditions contributing to AF pathogenesis, aiming to mitigate the risk of recurrence.

8.
Artigo em Inglês | MEDLINE | ID: mdl-38992888

RESUMO

BACKGROUND: The impact of sodium-glucose cotransporter 2 (SGLT2) inhibitors on the postoperative recurrence of atrial fibrillation (AF) in patients with persistent AF undergoing an initial radiofrequency ablation is not yet established. The objective of this study is to assess the impact of SGLT2 inhibitors on the recurrence of AF after radiofrequency ablation in patients with type 2 diabetes complicated persistent AF. METHODS: A total of 182 patients with type 2 diabetes and persistent AF, who underwent their first radiofrequency ablation for AF at our center, were enrolled and divided into two groups: the SGLT2 inhibitor group and the non-SGLT2 inhibitor group. The main outcome of the follow-up was the postoperative recurrence of AF. RESULTS: A total of 49 participants experienced AF recurrence. The use of SGLT2 inhibitors in patients with type 2 diabetes who underwent AF ablation was associated with a significantly lower risk of AF recurrence (adjusted hazard ratio: 0.65; 95% confidence interval: 0.28-0.83; p < .01). CONCLUSIONS: The use of SGLT2 inhibitors is associated with a decreased risk of arrhythmia recurrence after AF ablation in patients with type 2 diabetes complicated with persistent AF.

9.
JACC Clin Electrophysiol ; 10(7 Pt 2): 1689-1699, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39084743

RESUMO

BACKGROUND: Nonrandomized data suggest that longer diagnosis-to-ablation time (DAT) is associated with poorer outcomes; however, a recent randomized trial found no difference in recurrences when ablation was delayed by 12 months. OBJECTIVES: This study sought to assess the impact of DAT on atrial fibrillation (AF) recurrence in patients undergoing catheter ablation for persistent AF. METHODS: CAPLA (Effect of Catheter Ablation Using Pulmonary Vein Isolation With vs Without Posterior Left Atrial Wall Isolation on Atrial Arrhythmia Recurrence in Patients With Persistent Atrial Fibrillation: The CAPLA randomized clinical trial) was a multicenter trial that randomized patients with persistent AF to pulmonary vein isolation + posterior wall isolation or pulmonary vein isolation alone. Follow-up was 12 months. Outcomes were assessed after a 3-month blanking period. RESULTS: Median DAT in the 334 patients was 28 months (Q1-Q3: 12-66 months). Patients were divided into quartile groups: Q1 was DAT 0 to 12 months (n = 84, median DAT 7 months), Q2 was DAT 13 to 28 months (n = 85, median DAT 20 months), Q3 was DAT 29 to 66 months (n = 84, median DAT 41 months), and Q4 was DAT ≥67 months (n = 81, median DAT 119 months). AF recurrence rate was 36.9% for Q1, 44.7% for Q2, 47.6% for Q3, and 56.8% for Q4 (P = 0.082). On multivariable analysis, DAT Q4 was the only factor significantly associated with risk of recurrence (HR: 1.607; 95% CI: 1.005-2.570; P = 0.048). Median AF burden was 0% (Q1-Q3: 0%-0.47%) in Q1 and 0.33% (Q1-Q3: 0%-4.6%) in Q4 (P = 0.002). Quality of life (assessed by the Atrial Fibrillation Effect on Quality-of-Life questionnaire) improved markedly in all quartiles (Q1: Δ28.8 ± 24, Q2: Δ24.4 ± 23.4, Q3: Δ21.7 ± 26.6, Q4: Δ24.6 ± 21.4; P = 0.331). CONCLUSIONS: In a cohort of patients with persistent AF undergoing ablation in a prospective trial with standardized entry criteria and intensive electrocardiogram monitoring, those with shorter DAT had lower rates of AF recurrence. However, differences were modest, and all quartiles demonstrated very low AF burden and improvements in quality of life.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Recidiva , Humanos , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Veias Pulmonares/cirurgia , Resultado do Tratamento , Fatores de Tempo , Tempo para o Tratamento/estatística & dados numéricos
10.
Artigo em Inglês | MEDLINE | ID: mdl-39031283

RESUMO

At the beginning of the 21st century, approximately 2.3 million US adults had atrial fibrillation (AF), and there has been a 60% increase in hospital admissions for AF. Given that the expectancy is a continuous increase in incidence, it portends a severe healthcare problem. Considerable evidence supports the immune system and inflammatory response in cardiac tissue, and circulatory processes are involved in the physiopathology of AF. In this regard, finding novel inflammatory biomarkers that predict AF recurrence after catheter ablation (CA) is a prime importance global healthcare problem. Many inflammatory biomarkers and natriuretic peptides came out and were shown to have predictive capabilities for AF recurrence in patients undergoing CA. In this regard, some studies have shown that red blood cell distribution width (RDW) is associated with the risk of incident AF. This review aimed to provide an update on the evidence of the RDW as a biomarker of red cell dysfunction and its association with high systemic inflammation, and with the risk of incident AF. Through the literature review, we will highlight the most relevant studies of the RDW related to AF recurrence after CA. Many studies demonstrated that RDW is associated with all cause-mortality, heart failure, cardiovascular disease, and AF, probably because RDW is a biomarker of red blood cell dysfunction associated with high systemic inflammation, reflecting an advanced heart disease with prognostic implications in heart failure and cardiovascular disease. Thus, suggesting that could be a potential predictor for AF recurrence after CA. Moreover, the RDW is a parameter included in routine full blood count, which is low-cost, quick, and easy to obtain. We provided an update on the evidence of the most relevant studies of the RDW related to AF recurrence after CA, as well as the mechanism of the high RDW and its association with high systemic inflammation and prognostic marker in cardiovascular disease and heart failure.

11.
Cardiovasc Diabetol ; 23(1): 121, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38581024

RESUMO

BACKGROUND: This study investigates the relationship between triglyceride-glucose (TyG) index trajectories and the results of ablation in patients with stage 3D atrial fibrillation (AF). METHODS: A retrospective cohort study was carried out on patients who underwent AF Radiofrequency Catheter Ablation (RFCA) at the Cardiology Department of the Fourth Affiliated Hospital of Zhejiang University and Taizhou Hospital of Zhejiang Province from January 2016 to December 2022. The main clinical endpoint was determined as the occurrence of atrial arrhythmia for at least 30 s following a 3-month period after ablation. Using a latent class trajectory model, different trajectory groups were identified based on TyG levels. The relationship between TyG trajectory and the outcome of AF recurrence in patients was assessed through Kaplan-Meier survival curve analysis and multivariable Cox proportional hazards regression model. RESULTS: The study included 997 participants, with an average age of 63.21 ± 9.84 years, of whom 630 were males (63.19%). The mean follow-up period for the participants was 30.43 ± 17.75 months, during which 200 individuals experienced AF recurrence. Utilizing the minimum Bayesian Information Criterion (BIC) and the maximum Entropy principle, TyG levels post-AF RFCA were divided into three groups: Locus 1 low-low group (n = 791), Locus 2 low-high-low group (n = 14), and Locus 3 high-high group (n = 192). Significant differences in survival rates among the different trajectories were observed through the Kaplan-Meier curve (P < 0.001). Multivariate Cox regression analysis showed a significant association between baseline TyG level and AF recurrence outcomes (HR = 1.255, 95% CI: 1.087-1.448). Patients with TyG levels above 9.37 had a higher risk of adverse outcomes compared to those with levels below 8.67 (HR = 2.056, 95% CI: 1.335-3.166). Furthermore, individuals in Locus 3 had a higher incidence of outcomes compared to those in Locus 1 (HR = 1.580, 95% CI: 1.146-2). CONCLUSION: The TyG trajectories in patients with stage 3D AF are significantly linked to the outcomes of AF recurrence. Continuous monitoring of TyG levels during follow-up may help in identifying patients at high risk of AF recurrence, enabling the early application of effective interventions.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Estudos Retrospectivos , Teorema de Bayes , Resultado do Tratamento , Fatores de Risco , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
12.
Herz ; 49(2): 147-154, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37589750

RESUMO

BACKGROUND: This retrospective observational study investigated the relationship between heart rate variability (HRV) and atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI) by cryoballoon or radiofrequency ablation (RF). METHODS: We enrolled 497 patients who underwent PVI using first-generation cryoballoon (CB1), second-generation cryoballoon (CB2), or RF. We analyzed HRV as a surrogate for modulation of the intrinsic autonomic nervous system using 24­h Holter recordings 1 or 2 days after the procedure and compared the recurrence and non-recurrence group with regard to ablation methods. Furthermore, we calculated recurrence-free survival (RFS) below/over HRV cut-off values for the whole study population and separately for each ablation method. RESULTS: All except one of the five time-based HRV parameters analyzed were significantly lower in the non-recurrence group than in the recurrence group after CB2. Only a trend toward lower HRV for the non-recurrence group was found after RF and no remarkable differences were detected after CB1. The HRV parameters below their calculated cut-off were associated with a significantly higher RFS rate 2 years after CB2. This also applied to root mean sum of squared distance (rMSSD) and the percentage of adjacent NN interval differences greater than 50 ms (pNN50) after RF. No differences were found regarding CB1. Concerning rMSSD, the sensitivity, specificity, and difference in RFS increased when using cut-offs that were calculated including only CB2 patients. Multivariate cox regression analysis showed that low rMSSD values could independently predict AF recurrence after adjusting for covariates (hazard ratio: 0.50; p < 0.001). CONCLUSION: Low values of rMSSD early after a PVI could independently predict AF recurrence, especially after CB2.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Frequência Cardíaca , Veias Pulmonares/cirurgia , Resultado do Tratamento , Criocirurgia/métodos , Ablação por Cateter/métodos , Fatores de Tempo , Catéteres , Recidiva
13.
Ann Noninvasive Electrocardiol ; 29(1): e13095, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37986620

RESUMO

INTRODUCTION: Electrical cardioversion (ECV) is a frequently used procedure for restoring sinus rhythm in atrial fibrillation (AF); however, the rate of recurrence is high. The identification of patients at high risk of recurrence could influence the decision-making process. The present study evaluates the predictive value of risk scores in atrial fibrillation recurrence after elective electrical cardioversion. METHODS: Unicentric, observational, and prospective study of adult patients who have undergone an elective ECV as rhythm control strategy between July 2017 and September 2022. RESULTS: From the 283 analyzed patients (mean age 63.95 ± 10.76212, 74.9% male); 99 had paroxysmal AF (35%) and 159 (59%) presented AF recurrence during a follow-up of 6 months. In patients with post-ECV AF recurrence, the period of time from diagnosis until the performance of the procedure was longer (393 ± 891 vs. 195 ± 527, p = .02). No paroxysmal AF (71.3% vs. 57.8%, p = .02) and LA dilatation with >40 mL/m2 (35.9% vs. 23.3%, p = .02) volumes were more frequent within these patients. AF recurrence was more frequent in patients who had previous ECV (HR = 1.32; 95% CI: 1.12-2.35; p = .01) and more than 1 shock to recover sinus rhythm (HR = 1.62; 95% CI: 1.07-1.63; p = .01). The SLAC, ALARMEc, ATLAS, and CAAP-AF scores were statistically significant, although with a moderate predictive capacity for post-ECV recurrence. CONCLUSIONS: Risk scores analyzed showed a modest value predicting AF recurrence after ECV. Previous ECV, and greater difficulty in restoring SR were independent predictors of recurrence.


Assuntos
Fibrilação Atrial , Adulto , Humanos , Masculino , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Estudos Prospectivos , Cardioversão Elétrica/métodos , Eletrocardiografia , Fatores de Risco , Recidiva , Resultado do Tratamento
14.
Pacing Clin Electrophysiol ; 47(1): 19-27, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38041418

RESUMO

BACKGROUND: Recent studies have shown that atrial slow conduction velocity (CV) is associated with the perpetuation of atrial fibrillation (AF). However, the criteria of CV measurement have not been standardized. The aim of this study was to evaluate the relationship between the slow CV area (SCVA) measured by novel omnipolar technology (OT) and AF recurrence. METHODS: This study included 90 patients with AF who underwent initial pulmonary vein isolation (PVI). The segmented surface area of the SCVA was measured by left atrial (LA) electrophysiological mapping using OT before the PVI. The proportion of the SCVA at each cutoff value of CV (from < 0.6 to < 0.9 m/s) was compared between the patients with and without AF recurrence. RESULTS: During a mean follow-up period of 516 ± 197 days, the recurrence of AF after the initial PVI was observed in 23 (25.5%) patients. In patients with AF recurrence, the proportion of the SCVA in the LA posterior, LA appendage (LAA), and LA anterior were significantly higher than those without AF recurrence. The multivariate analysis indicated that the proportion of the low voltage area and the SCVA in the LA anterior (local CV < 0.7 m/s) were independent predictors of AF recurrence (hazard ratio [HR], 1.07; 95% confidence interval [CI], 1.01-1.14; p = 0.03; HR, 1.40; 95% CI, 1.07-1.83; p = 0.01, respectively). CONCLUSION: By evaluating the local CV using OT, it was indicated that SCVA with CV < 0.7 m/s in the LA anterior is strongly associated with AF recurrence after PVI.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Átrios do Coração , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
15.
J Interv Card Electrophysiol ; 67(3): 479-492, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37414922

RESUMO

BACKGROUND: Impaired left atrial (LA) strain predicts atrial fibrillation (AF) recurrence after catheter ablation (CA), but currently there is no cut-off to guide patient selection for CA. Integrated backscatter (IBS) is a promising tool for noninvasive quantification of myocardial fibrosis. The aim of this study was to compare LA strain and IBS between paroxysmal, persistent, and long-standing persistent AF and evaluate their association with AF recurrence after CA. METHODS: Analysis of consecutive patients with symptomatic paroxysmal and persistent AF who underwent CA. LA phasic strain, strain rate and IBS were assessed by two-dimensional speckle-tracking at baseline. RESULTS: We analyzed 78 patients, 31% with persistent AF (46% long-standing AF), 65% male, mean age 59 ± 14 years, who underwent CA and were followed-up for 12 months. AF recurrence occurred in 22 (28%) patients. LA phasic strain parameters were significantly impaired in patients with AF recurrence and were independent predictors of AF recurrence in a multivariable analysis. LA reservoir strain (LASr) < 18% predicted AF recurrence with 86% sensitivity and 71% specificity, with a higher predictive power compared to LA volume index (LAVI). LASr < 22% in paroxysmal AF and LASr < 12% in persistent AF correlated with AF recurrence. Increased IBS was a predictor of AF recurrence in patients with paroxysmal AF. CONCLUSION: LA phasic strain parameters were predictors of AF recurrence after CA, independently of LAVI and AF subtype. LASr < 18% showed a higher predictive power compared to LAVI. Further studies are needed to investigate the role of IBS as a predictor of AF recurrence.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ecocardiografia/métodos , Resultado do Tratamento , Valor Preditivo dos Testes , Átrios do Coração/cirurgia , Ablação por Cateter/métodos , Recidiva
16.
China Modern Doctor ; (36): 33-37, 2024.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1038118

RESUMO

Objective To compare the different therapeutic efficacies between radiofrequency and cryoballoon ablation in atrial fibrillation(AF)patients with enlarged left atrium.Methods A total of 106 AF patients with enlarged left atrium(LAVI)>34ml/m2 who visited our center between December 2016 and May 2022 for catheter ablation were enrolled.They were divided into radiofrequency group(R-group)and cryoballoon group(C-group)according to the procedure.The recurrence of AF was compared between the two groups.Results The median follow-up time was 12 months and no death occurred.The rate of loss of follow-up was 3.8%.The overall recurrence rate of AF after ablation was 36.8%.There was no significant difference in clinical baseline between the two groups(P>0.05).The radiofrequency group had longer operation time(P<0.001),shorter X-ray time and less exposure(P<0.05);There was no significant difference in clinical baseline and postoperative complications between the two groups(P>0.05).The results of survival analysis showed that there was no significant difference in the survival rate of patients without atrial fibrillation/atrial flutter/atrial tachycardia between the two groups(P>0.05).Conclusion For AF patients with enlarged left atrium,the clinical effects of the two methods were similar.Cryoballoon takes a shorter time,while radiofrequency has a lower X-ray time and exposure dose for physicians and patients.Therefore,appropriate ablation methods should be selected according to the actual situation.

17.
Cureus ; 15(10): e46545, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37927624

RESUMO

Atrial fibrillation (AF) is a common arrhythmia among patients with chronic kidney disease (CKD), which leads to increased cardiovascular complications. Catheter ablation (CA) has emerged as an effective and safe treatment for AF in CKD patients. CA offers tailored treatment strategies and presents a safer alternative with fewer adverse outcomes than anti-arrhythmic agents. Although CKD patients undergoing ablation have similar complication rates to non-CKD patients, they face a higher risk of hospitalization due to heart failure. Furthermore, CA shows promise in improving kidney function, particularly in individuals who maintain sinus rhythm. Future research should address limitations by including advanced CKD patients, conducting longer-term follow-ups, and developing individualized treatment approaches.

18.
Cureus ; 15(8): e43992, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37641724

RESUMO

It is expected that the prevalence of atrial fibrillation (AF), the most prevalent cardiac arrhythmia among people aged 65 to 85, would be mostly classified using the CHAS2DS2-VASc approach for anticoagulation therapy. A high number of people in the entire world will be living with AF by 2030. Long-term follow-up data are sparse, although radiofrequency catheter ablation (CA) for symptomatic AF patients has the potential to be a curative therapy. Although women are referred later and less often than men, the outcomes following ablation are comparable across both genders. Health-related quality of life suffers from AF, and patients often find themselves less active as a result of their condition. AF may have a wide variety of symptoms and signs from the clinic's point of view. Women are more likely to exhibit symptoms than men; one reason for this is that women have an average QT interval that is 10-20 milliseconds longer than men, which is more likely to exacerbate tachycardia symptoms. In search of medical databases for relevant medical literature, we looked at PubMed/Medline, the Cochrane Library, and Google Scholar. Ten publications were gathered after the papers were located, assessed, and qualifying criteria applied were used to select them. The finished articles were done to give an overview of the effectiveness of ablation therapy for AF. Some studies showed that there was no statistical significance between invasive and pharmacological treatments. Other research found no difference in the recurrence of atrial arrhythmia between pulmonary vein isolation (PVI) CA alone and PVI + enhancement magnetic resonance imaging (MRI)-guided fibrosis ablation in individuals with persistent AF. The oldest individuals in studies comparing CA to medical treatment for AF demonstrated no improvement in prognosis after CA. Also, complications from therapy and CA's efficacy in preventing future atrial arrhythmias were similarly low across all age groups. Based on the above, we concluded that more studies are required to establish the most effective approach to treating AF to apply it in daily practice and gain more knowledge about it.

19.
J Clin Med ; 12(11)2023 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-37297892

RESUMO

AIMS: Association of two-(2D) and three-dimensional (3D) left atrial strain (LAS) and low-voltage area (LVA) with recurrence of atrial fibrillation (AF) after pulmonary vein isolation (PVI) was assessed. METHODS AND RESULTS: 3D LAS, 2D LAS, and LVA were obtained in 93 consecutive patients undergoing PVI and recurrence of AF was analyzed prospectively. AF recurred in 12 patients (13%). The 3D left atrial reservoir strain (LARS) and pump strain (LAPS) were lower in patients with recurrent AF than without (p = 0.008 and p = 0.009, respectively). In univariable Cox regression, 3D LARS or LAPS were associated with recurrent AF (LARS: HR = 0.89 (0.81-0.99), p = 0.025; LAPS: HR = 1.40 (1.02-1.92), p = 0.040), while other values were not. Association of 3D LARS or LAPS with recurrent AF was independent of age, body mass index, arterial hypertension, left ventricular ejection fraction, and end-diastolic volume index and left atrial volume index in multivariable models. Kaplan-Meier curves revealed that patients with 3D LAPS < -5.9% did not exhibit recurrent AF, while those >-5.9% had a significant risk of recurrent AF. CONCLUSIONS: 3D LARS and LAPS were associated with recurrent AF after PVI. Association of 3D LAS was independent of relevant clinical and echocardiographic parameters and improved their predictive value. Hence, they may be applied for outcome prediction in patients undergoing PVI.

20.
Jpn J Radiol ; 41(9): 955-964, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37040024

RESUMO

PURPOSE: Quantitative measurement of pericoronary adipose tissue volume (PCATV) and fat attenuation index (FAI) has mostly been used in the study of coronary artery related diseases but rarely in the relationship with atrial fibrillation (AF). This study was conducted to investigate the correlation of PCATV and FAI with the AF recurrence after ablation and the clinical significance. MATERIALS AND METHODS: Patients with continuous AF who underwent radiofrequency ablation and computed tomographic angiography (CTA) were retrospectively enrolled. The PCATV, FAI, epicardial adipose tissue volume (EATV) and EAT density (EATD) arround the three main branches of the coronary arteries (LAD, LCX, and RCA) were measured quantitatively with cardiac function software and analyzed. RESULTS: 189 patients with continuous AF who underwent radiofrequency ablation for the first time were enrolled. After 12-month follow-up with a mean follow-up time of 10.93 ± 0.16 months, 47 (24.9%) patients were confirmed to have AF recurrence. The 3 V-FAI (- 81.17 ± 4.27 vs. - 83.31 ± 4.59 HU, P = 0.005), LCX-FAI (median - 77 vs. median - 81HU, P < 0.001), EATV (median 141.14vs. median 125.39 ml, P = 0.010), and EATVI (median 70.77 vs. 66.73 ml/m2, P = 0.008) were significantly increased in the recurrence group. EATVI (OR 1.043, 95% CI 1.020-1.066) and LCX-FAI (OR 1.254, 95% CI 1.145-1.374) were two significant independent risk factors for AF recurrence. In the comparison of ROC, the predictive value of LCX-FAI (cut-off value of >- 81.5 HU, area under the curve (AUC) of 0.722) was higher than that of EATVI (cut-off value > 81.07 ml/m2, AUC of 0.630). CONCLUSION: EATVI and LCX-FAI were related to recurrence of AF after ablation and have important clinical value in predicting the AF recurrence.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Doença da Artéria Coronariana , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Estudos Retrospectivos , Tecido Adiposo/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Angiografia por Tomografia Computadorizada , Angiografia , Recidiva , Ablação por Cateter/métodos , Angiografia Coronária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA