Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 398
Filtrar
1.
Curr Res Transl Med ; 72(4): 103458, 2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38943898

RESUMO

Hydrogels are commonly used as carriers for cell delivery due to their similarities to the extracellular matrix. A contraction-suppressed full-thickness wound model was used to evaluate the therapeutic potential of Pluronic F127 (PF127) hydrogel loaded with adipose-derived stromal vascular fraction (AdSVF), mesenchymal stem cells (AdMSC), and conditioned media (AdMSC-CM) for the repair of wounds in a rabbit model. The experimental study was conducted on forty-eight healthy adult New Zealand white rabbits randomly divided into eight groups with six animals each and treated with AdSVF, AdMSC, and AdMSC-CM as an injectable or topical preparation. The healing potential of different adipose-derived cell-based and cell-free therapeutics was evaluated based on percentage wound healing, period of epithelialization, epidermal thickness, scar evaluation, histopathology analysis, histochemical evaluation, immunohistochemistry (collagen type I), and hydroxyproline assay by comparing with the positive and negative control. Collagen density analysis using different staining methods, immunohistochemistry, and hydroxyproline assay consistently showed that delivering AdMSC and AdMSC-CM in PF127 hydrogel enhanced epithelialization, collagen production, and organization, contributing to improved tissue strength and quality. Even though allogeneic AdSVF was found to promote wound healing in rabbits, it has a lower potential than AdMSC and AdMSC-CM. The wound healing potential of AdMSC and AdMSC-CM was enhanced when loaded in PF127 hydrogel and applied topically. Even though wounds treated with AdMSC outperformed AdMSC-CM, a significant difference in the healing quality was not observed in most instances, indicating almost similar therapeutic potential. The findings indicate that the wound healing potential of AdMSC and AdMSC-CM was enhanced when loaded in PF127 hydrogel and applied topically. These treatments promoted collagen production, tissue organization, and epidermal regeneration, ultimately improving overall healing outcomes.

2.
Adv Mater ; : e2402491, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38837481

RESUMO

Self-powered electrical bandages (SEBs), integrated with wearable energy harvesters, can provide an effective and autonomous electrical stimulation (ES) solution for rapid and scarless wound healing. A continuously operating, wireless, and applicable-to-comprehensive-wound ES device is essential for the quick restoration of wounds and convenience. This work illustrates a SEB powered by body-coupled energy harvesting. The SEB continuously treats the wound with 60-Hz sinusoidal electrical potential gained from the coupling of the human body and ambient electrical waves. It is demonstrated that enough level of electrical potential can be applied to the wound, further enhanced by strong capacitive coupling arising from the use of high-permittivity poly(vinylidene fluoride-trifluoroethylene):CaCu3Ti4O12 (P(VDF-TrFE):CCTO) nanocomposite. The potential clinical efficacy of the SEB is illustrated by preclinical analysis of human fibroblasts and mouse wound model, thus confirming the successful expedition of wound recovery. This work suggests a new class of wearable devices to provide ES events and its potential for extension to other conventional wound care materials and device technology.

3.
BMC Musculoskelet Disord ; 25(1): 469, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38879465

RESUMO

PURPOSE: The aim of this study was to compare the clinical outcomes between patients with chronic ankle instability (CAI) undergoing arthroscopic anterior talofibular ligament (ATFL) repair who received elastic bandage treatment and those who received lower-leg cast immobilization. METHODS: CAI patients with isolated ATFL injury undergoing arthroscopic ATFL repair from January 2017 and August 2019 were included in the study. The visual analogue scale (VAS) at rest and during activities, American Orthopedic Foot and Ankle Society (AOFAS) score, Karlsson Ankle Functional Score (Karlsson score), and time of returning to walk, walk normally, work and sports were evaluated preoperatively, and at 6 months and 12 months follow-up. RESULTS: A total of 41 patients were included in this study. Among them, 24 patients accepted lower-leg cast fixation, and the other 17 patients were immobilized with elastic bandage. Compared to patients with lower-leg immobilization, patients with elastic bandage fixation had significantly lower VAS during activities (P = 0.021) and higher AOFAS score (P = 0.015) at 12 months follow-up. The Karlsson score at 6 months follow-up were significantly higher in elastic bandage group than those in lower-leg group (P = 0.011). However, no significant difference was observed in time of returning to walk, work and sports between the two groups. CONCLUSION: Elastic bandage treatment was better than lower-leg cast immobilization in terms of eliminating pain symptom at 12 months follow-up, and improving ankle functional outcome at 6 months follow-up. Moreover, the present study emphasized that lower-leg cast immobilization offered no advantages in arthroscopic ATFL repair postoperative immobilization. STUDY DESIGN: Cohort study; Level of evidence, 3.


Assuntos
Moldes Cirúrgicos , Instabilidade Articular , Ligamentos Laterais do Tornozelo , Humanos , Feminino , Masculino , Adulto , Ligamentos Laterais do Tornozelo/cirurgia , Ligamentos Laterais do Tornozelo/lesões , Resultado do Tratamento , Instabilidade Articular/cirurgia , Adulto Jovem , Articulação do Tornozelo/cirurgia , Articulação do Tornozelo/fisiopatologia , Artroscopia/métodos , Estudos Retrospectivos , Traumatismos do Tornozelo/cirurgia , Traumatismos do Tornozelo/terapia , Imobilização/métodos , Pessoa de Meia-Idade , Recuperação de Função Fisiológica , Seguimentos
4.
Clin Ophthalmol ; 18: 1329-1339, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38765455

RESUMO

Purpose: To assess changes in symptoms and ocular surface signs following a bilateral sutureless treatment of dehydrated amniotic membrane (dAM) under a specialised bandage contact lens (sBCL) in patients with moderate-to-severe dry eye disease (DED). Patients and Methods: In this prospective pre-post interventional study, 35 patients diagnosed with moderate-to-severe DED, with an Ocular Surface Disease Index (OSDI) score >30 on current treatment, were enrolled. Assessments were conducted at baseline (day -30), after 30 days run-in with no additional treatment (day 0 - control), and 30 days post sBCL+dAM treatment (day 30 - treatment). Intervention involved two successive bilateral 4-5 day sutureless applications of dAM (17mm diameter, with a 6 mm central aperture, Omnigen® VIEW) under an 18mm sBCL (OmniLenz®). Symptomatology and ocular signs were measured using OSDI, Dry Eye Questionnaire-5 (DEQ-5), Symptom Assessment iN Dry Eye (SANDE), and other ocular surface health indicators including non-invasive breakup time, corneal and conjunctival staining, and lid wiper epitheliopathy length and width (LWE). Results: While symptomatology remained stable during the 30-day no-treatment run-in, 1-month post-dAM treatment, there was a significant reduction in OSDI scores (from 55.8 to 32.3, p<0.001), DEQ-5 (from 14.6 to 10.0, p<0.001), SANDE frequency (from 65.2 to 43.6, p<0.001), and SANDE severity (from 59.8 to 41.1, p<0.001). Additionally, there was a notable decrease in the width of LWE staining, from grade 2 (50-75% of the lid wiper) to grade 1 (25-50% of the lid wiper) (p=0.011). Conclusion: A bilateral 8-10-day treatment duration with dAM applied with sBCL demonstrated a 31 to 42% improvement in symptomatology and a decrease in ocular surface signs of mechanical stress. This innovative bilateral treatment approach offers a promising treatment modality for patients with refractory moderate-to-severe DED.

5.
Biomimetics (Basel) ; 9(5)2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38786488

RESUMO

Biomimetic materials have become a promising alternative in the field of tissue engineering and regenerative medicine to address critical challenges in wound healing and skin regeneration. Skin-mimetic materials have enormous potential to improve wound healing outcomes and enable innovative diagnostic and sensor applications. Human skin, with its complex structure and diverse functions, serves as an excellent model for designing biomaterials. Creating effective wound coverings requires mimicking the unique extracellular matrix composition, mechanical properties, and biochemical cues. Additionally, integrating electronic functionality into these materials presents exciting possibilities for real-time monitoring, diagnostics, and personalized healthcare. This review examines biomimetic skin materials and their role in regenerative wound healing, as well as their integration with electronic skin technologies. It discusses recent advances, challenges, and future directions in this rapidly evolving field.

6.
Int J Mol Sci ; 25(9)2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38732168

RESUMO

Antimicrobial resistance (AMR) poses an emanating threat to humanity's future. The effectiveness of commonly used antibiotics against microbial infections is declining at an alarming rate. As a result, morbidity and mortality rates are soaring, particularly among immunocompromised populations. Exploring alternative solutions, such as medicinal plants and iodine, shows promise in combating resistant pathogens. Such antimicrobials could effectively inhibit microbial proliferation through synergistic combinations. In our study, we prepared a formulation consisting of Aloe barbadensis Miller (AV), Thymol, iodine (I2), and polyvinylpyrrolidone (PVP). Various analytical methods including SEM/EDS, UV-vis, Raman, FTIR, and XRD were carried out to verify the purity, composition, and morphology of AV-PVP-Thymol-I2. We evaluated the inhibitory effects of this formulation against 10 selected reference strains using impregnated sterile discs, surgical sutures, gauze bandages, surgical face masks, and KN95 masks. The antimicrobial properties of AV-PVP-Thymol-I2 were assessed through disc diffusion methods against 10 reference strains in comparison with two common antibiotics. The 25-month-old formulation exhibited slightly lower inhibitory zones, indicating changes in the sustained-iodine-release reservoir. Our findings confirm AV-PVP-Thymol-I2 as a potent antifungal and antibacterial agent against the reference strains, demonstrating particularly strong inhibitory action on surgical sutures, cotton bandages, and face masks. These results enable the potential use of the formulation AV-PVP-Thymol-I2 as a promising antimicrobial agent against wound infections and as a spray-on contact-killing agent.


Assuntos
Testes de Sensibilidade Microbiana , Timol , Timol/farmacologia , Timol/química , Iodo/química , Iodo/farmacologia , Anti-Infecciosos/farmacologia , Anti-Infecciosos/química , Aloe/química , Antibacterianos/farmacologia , Antibacterianos/química , Humanos , Composição de Medicamentos/métodos
7.
Antimicrob Agents Chemother ; 68(7): e0172223, 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38771032

RESUMO

Chronic wound infections can be difficult to treat and may lead to impaired healing and worsened patient outcomes. Novel treatment strategies are needed. This study evaluated the effects of intermittently produced hydrogen peroxide (H2O2) and hypochlorous acid (HOCl), generated via an electrochemical bandage (e-bandage), against methicillin-resistant Staphylococcus aureus biofilms in an agar membrane biofilm model. By changing the working electrode potential, the e-bandage generated either HOCl (1.5 VAg/AgCl) or H2O2 (-0.6 VAg/AgCl). The degree of biocidal activity of intermittent treatment with HOCl and H2O2 correlated with HOCl treatment time; HOCl treatment durations of 0, 1.5, 3, 4.5, and 6 hours (with the rest of the 6-hour total treatment time devoted to H2O2 generation) resulted in mean biofilm reductions of 1.36 ± 0.2, 2.22 ± 0.16, 3.46 ± 0.38, 4.63 ± 0.74, and 7.66 ± 0.5 log CFU/cm2, respectively, vs. non-polarized controls, respectively. However, application of H2O2 immediately after HOCl treatment was detrimental to biofilm removal. For example, 3 hours HOCl treatment followed by 3 hours H2O2 resulted in a 1.90 ± 0.84 log CFU/cm2 lower mean biofilm reduction than 3 hours HOCl treatment followed by 3 hours non-polarization. HOCl generated over 3 hours exhibited biocidal activity for at least 7.5 hours after e-bandage operation ceased; 3 hours of HOCl generation followed by 7.5 hours of non-polarization resulted in a biofilm cell reduction of 7.92 ± 0.12 log CFU/cm2 vs. non-polarized controls. Finally, intermittent treatment with HOCl (i.e., interspersed with periods of e-bandage non-polarization) for various intervals showed similar effects (approximately 6 log CFU/cm2 reduction vs. non-polarized control) to continuous treatment with HOCl for 3 hours, followed by 3 hours of non-polarization. These findings suggest that timing and sequencing of HOCl and H2O2 treatments are crucial for maximizing biofilm control when using an e-bandage strategy.


Assuntos
Biofilmes , Peróxido de Hidrogênio , Ácido Hipocloroso , Staphylococcus aureus Resistente à Meticilina , Biofilmes/efeitos dos fármacos , Peróxido de Hidrogênio/farmacologia , Ácido Hipocloroso/farmacologia , Staphylococcus aureus Resistente à Meticilina/efeitos dos fármacos , Antibacterianos/farmacologia , Testes de Sensibilidade Microbiana
8.
Int J Biol Macromol ; 267(Pt 2): 131650, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38636756

RESUMO

Diabetic wounds are a common complication of diabetes. The prolonged exposure to high glucose and oxidative stress in the wound environment increases the risk of bacterial infection and abnormal angiogenesis, leading to amputation. Microneedle patches have shown promise in promoting the healing of diabetic wounds through transdermal drug delivery. These patches target the four main aspects of diabetic wound treatment: hypoglycemia, antibacterial action, inflammatory regulation, and tissue regeneration. By overcoming the limitations of traditional administration methods, microneedle patches enable targeted therapy for deteriorated tissues. The design of these patches extends beyond the selection of needle tip material and biomacromolecule encapsulated drugs; it can also incorporate near-infrared rays to facilitate cascade reactions and treat diabetic wounds. In this review, we comprehensively summarize the advantages of microneedle patches compared to traditional treatment methods. We focus on the design and mechanism of these patches based on existing experimental articles in the field and discuss the potential for future research on microneedle patches.


Assuntos
Sistemas de Liberação de Medicamentos , Agulhas , Cicatrização , Humanos , Administração Cutânea , Diabetes Mellitus , Sistemas de Liberação de Medicamentos/métodos , Adesivo Transdérmico , Cicatrização/efeitos dos fármacos
9.
bioRxiv ; 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38586004

RESUMO

Chronic wound infections can be difficult to treat and may lead to impaired healing and worsened patient outcomes. Novel treatment strategies are needed. This study evaluated effects of intermittently produced H2O2 and HOCl, generated via an electrochemical bandage (e-bandage), against methicillin-resistant Staphylococcus aureus biofilms in an agar membrane biofilm model. By changing the working electrode potential, the e-bandage generated either HOCl (1.5 VAg/AgCl) or H2O2 (-0.6 VAg/AgCl). The degree of biocidal activity of intermittent treatment with HOCl and H2O2 correlated with HOCl treatment time; HOCl treatment durations of 0, 1.5, 3, 4.5, and 6 hours (with the rest of the 6 hour total treatment time devoted to H2O2 generation) resulted in mean biofilm reductions of 1.36±0.2, 2.22±0.16, 3.46±0.38, 4.63±0.74 and 7.66±0.5 log CFU/cm2, respectively vs. non-polarized controls, respectively. However, application of H2O2 immediately after HOCl treatment was detrimental to biofilm removal. For example, 3-hours HOCl treatment followed by 3-hours H2O2 resulted in a 1.90±0.84 log CFU/cm2 lower mean biofilm reduction than 3-hours HOCl treatment followed by 3-hours non-polarization. HOCl generated over 3-hours exhibited biocidal activity for at least 7.5-hours after e-bandage operation ceased; 3-hours of HOCl generation followed by 7.5-hours of non-polarization resulted in a biofilm cell reduction of 7.92±0.12 log CFU/cm2 vs. non polarized controls. Finally, intermittent treatment with HOCl (i.e., interspersed with periods of e-bandage non-polarization) for various intervals showed similar effects (approximately 6 log CFU/cm2 reduction vs. non-polarized control) to continuous treatment with HOCl for 3-hours, followed by 3-hours of non-polarization. These findings suggest that timing and sequencing of HOCl and H2O2 treatments are crucial for maximizing biofilm control.

10.
bioRxiv ; 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38562889

RESUMO

Wound infections, exacerbated by the prevalence of antibiotic-resistant bacterial pathogens, necessitate innovative antimicrobial approaches. Polymicrobial infections, often involving Pseudomonas aeruginosa and methicillin-resistant Staphylococcus aureus (MRSA), present formidable challenges due to biofilm formation and antibiotic resistance. Hypochlorous acid (HOCl), a potent antimicrobial agent produced naturally by the immune system, holds promise as an alternative therapy. An electrochemical bandage (e-bandage) that generates HOCl in situ was evaluated for treatment of murine wound biofilm infections containing both MRSA and P. aeruginosa with "difficult-to-treat" resistance. Previously, the HOCl-producing e-bandage was shown to reduce wound biofilms containing P. aeruginosa alone. Compared to non-polarized e-bandage (no HOCl production) and Tegaderm only controls, the polarized e-bandages reduced bacterial loads in wounds infected with MRSA plus P. aeruginosa (MRSA: vs Tegaderm only - 1.4 log10 CFU/g, p = 0.0015, vs. non-polarized - 1.1 log10 CFU/g, p = 0.026. P. aeruginosa: vs Tegaderm only - 1.6 log10 CFU/g, p = 0.0015, vs non-polarized - 1.6 log10 CFU/g, p = 0.0032), and MRSA alone (vs Tegaderm only - 1.3 log10 CFU/g, p = 0.0048, vs. non-polarized - 1.1 log10 CFU/g, p = 0.0048), without compromising wound healing or causing tissue toxicity. Addition of systemic antibiotics did not enhance the antimicrobial efficacy of e-bandages, highlighting their potential as standalone therapies. This study provides additional evidence for the HOCl-producing e-bandage as a novel antimicrobial strategy for managing wound infections, including in the context of antibiotic resistance and polymicrobial infections.

11.
J Diabetes ; 16(5): e13554, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38664883

RESUMO

Diabetic wounds cannot undergo normal wound healing due to changes in the concentration of hyperglycemia in the body and soon evolve into chronic wounds causing amputation or even death of patients. Diabetic wounds directly affect the quality of patients and social medical management; thus researchers started to focus on skin transplantation technology. The acellular fish skin grafts (AFSGs) are derived from wild fish, which avoids the influence of human immune function and the spread of the virus through low-cost decellularization. AFSGs contain a large amount of collagen and omega-3 polyunsaturated fatty acids and they have an amazing effect on wound regeneration. However, after our search in major databases, we found that there were few research trials in this field, and only one was clinically approved. Therefore, we summarized the advantages of AFSGs and listed the problems faced in clinical use. The purpose of this paper is to enable researchers to better carry out original experiments at various stages.


Assuntos
Transplante de Pele , Cicatrização , Humanos , Animais , Transplante de Pele/métodos , Peixes , Pé Diabético/cirurgia , Pé Diabético/terapia
12.
Polymers (Basel) ; 16(5)2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38475347

RESUMO

Nanofibrous materials represent a very promising form of advanced carrier systems that can be used industrially, especially in regenerative medicine as highly functional bandages, or advanced wound dressings. By incorporation of antimicrobial additives directly into the structure of the nanofiber carrier, the functionality of the layer is upgraded, depending on the final requirement-bactericidal, bacteriostatic, antiseptic, or a generally antimicrobial effect. Such highly functional nanofibrous layers can be prepared mostly by electrospinning technology from both synthetic and natural polymers. The presence of a natural polymer in the composition is very advantageous. Especially in medical applications where, due to the presence of the material close to the human body, the healing process is more efficient and without the occurrence of an unwanted inflammatory response. However, converting natural polymers into nanofibrous form, with a homogeneously distributed and stable additive, is a great challenge. Thus, a combination of natural and synthetic materials is often used. This review clearly summarizes the issue of the incorporation and effectiveness of different types of antimicrobial substances, such as nanoparticles, antibiotics, common antiseptics, or substances of natural origin, into electrospun nanofibrous layers made of mostly natural polymer materials. A section describing the problematic aspects of antimicrobial polymers is also included.

13.
Cureus ; 16(2): e54156, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38496151

RESUMO

Klippel-Trenaunay syndrome (KTS) is also associated with venous thrombosis originating from varicose veins in the lower extremities, pulmonary embolism, and pulmonary hypertension. This study describes the anesthetic management of laparoscopic cholecystectomy in a 54-year-old male KTS patient with orthostatic hypotension due to massive varicose veins in the lower extremities and pulmonary thromboembolism. Compressing the varicosities with an elastic bandage can maintain stable circulatory dynamics even under general anesthesia management to prevent position and insufflation-induced changes that can occur spontaneously.

14.
Front Sports Act Living ; 6: 1351906, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38500545

RESUMO

While the prevailing treatment for corneal abrasions outside the athletic sphere is the application of a bandage contact lens (BCL), which lessens pain and allows for the maintenance of binocular vision, this is not the case during athletic play. This brief report highlights the advantage of BCLs in treating in-game corneal abrasions, ultimately allowing for an immediate return to play. Additionally, this report summarizes the mechanisms of bandage contact lenses, differentiates them from standard hydrogel contact lenses, and highlights the significant steps necessary to apply the bandage contact lens during an in-game corneal abrasion event. Overall, we link modern ophthalmology clinical practice and sports medicine, allowing for the attenuation of acutely-induced ocular pain to a manageable state.

15.
Dent J (Basel) ; 12(3)2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38534294

RESUMO

Oral mucosa inflammation can cause severe pain and interfere with eating, reducing quality of life. However, few options for self-care are available. An oral liquid bandage forms a protective film over the affected area. We aimed to assess the acid erosion risk when a newly developed oral liquid bandage (ORAPLA) is accidentally deposited on teeth and to examine the relative acid erosion risk at multiple time points of the maximum recommended duration of continuous use. ORAPLA was applied to both enamel and dentin blocks from 45 bovine anterior mandibular teeth, and an acid challenge was performed in a simulated oral cavity with artificial saliva, with one exposure cycle lasting 6 h. The enamel showed substantial defects and a decrease in Vickers hardness after nine cycles, with no change in surface roughness. Dentin showed an increase in parenchymal defects and surface roughness and a trend toward decreased Vickers hardness with increasing exposure time. We found no significant acid corrosion in enamel after up to nine times the upper limit of normal use time or in dentin after up to six times the upper limit. We conclude that the acid erosion risk due to accidental attachment to teeth is low, and in the human oral cavity with salivary buffering and remineralization, likely even lower.

16.
BMC Ophthalmol ; 24(1): 141, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38549070

RESUMO

PURPOSE: In the present study, we aimed to evaluate the efficacy of the bandage contact lens (BCLs) in the treatment of dry eye disease (DED) after complicated cataract or/and intraocular lens (IOL) surgery. METHODS: In this retrospective, single-centered, observational study, we collected data from 69 patients who underwent complicated cataract or/and IOL surgery. Of these, 35 cases wore their own BCLs immediately after the operation, while the other 34 cases did not have their own BCLs and were instead covered with gauze. The Ocular Surface Disease Index (OSDI) questionnaire, slit-lamp microscope examination, keratograph analysis, and Schirmer I test were measured at baseline, 1 week and 1 month postoperatively. RESULTS: In the BCL group, the score of the OSDI questionnaire was significantly decreased at 1 week and 1 month postoperatively compared with baseline levels (P = 0.000, collectively). Moreover, the fluorescein staining score of the BCL group was remarkably decreased 1-week and 1-month postoperatively compared with the non-BCL group (P = 0.000 and P = 0.000, respectively). Furthermore, the redness score of the BCL group was also better compared with the non-BCL group at 1 week and 1 month postoperatively (P = 0.014 and P = 0.004, respectively). CONCLUSIONS: Complicated cataract or/and IOL surgery would intensify the DED. Early application of BCLs postoperatively improved patients' comfort and alleviated dry eye-related symptoms and signs. Furthermore, this mechanism might involve the acceleration of corneal epithelial healing, the alleviation of ocular stress response and the stabilization of the tear film. TRIAL REGISTRATION: Trial registration ClinicalTrials, NCT04120389. Registered 10 October 2019-retrospectively registered.


Assuntos
Catarata , Lentes de Contato Hidrofílicas , Síndromes do Olho Seco , Lentes Intraoculares , Humanos , Estudos Retrospectivos , Lentes Intraoculares/efeitos adversos , Catarata/complicações , Síndromes do Olho Seco/etiologia , Síndromes do Olho Seco/diagnóstico , Lentes de Contato Hidrofílicas/efeitos adversos , Bandagens/efeitos adversos
17.
Front Public Health ; 12: 1331753, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38450128

RESUMO

Introduction: Silver-releasing dressings are used in the treatment of infected wounds. Despite their widespread use, neither the amount of silver released nor the potential in vivo toxicity is known. The aim of this study was to evaluate the cytotoxic effects and the amount of silver released from commercially available dressings with infected wounds. Methods: The review was conducted according to the PRISMA statement. The Web of Science, PubMed, Embase, Scopus, and CINAHL databases were searched for studies from 2002 through December 2022. The criteria were as follows: population (human patients with infected wounds); intervention (commercial dressings with clinical silver authorized for use in humans); and outcomes (concentrations of silver ions released into tissues and plasma). Any study based on silver-free dressings, experimental dressings, or dressings not for clinical use in humans should be excluded. According to the type of study, systematic reviews, experimental, quasi-experimental, and observational studies in English, Spanish, or Portuguese were considered. The quality of the selected studies was assessed using the JBI critical appraisal tools. Studies that assessed at least 65% of the included items were included. Data were extracted independently by two reviewers. Results: 740 articles were found and five were finally selected (all of them quasi-experimental). Heterogeneity was found in terms of study design, application of silver dressings, and methods of assessment, which limited the comparability between studies. Conclusion: In vivo comparative studies of clinical dressings for control of infection lack a standardized methodology that allows observation of all the variables of silver performance at local and systemic levels, as well as evaluation of its cytotoxicity. It cannot be concluded whether the assessed concentrations of released silver in commercial dressings for the topical treatment of infected wounds are cytotoxic to skin cells. Systematic review registration: https://www.crd.york.ac.uk/prospero/display_record.php?ID=CRD42022351041, PROSPERO [CRD42022351041].


Assuntos
Prata , Infecção dos Ferimentos , Humanos , Bandagens , Bases de Dados Factuais , Íons , Prata/uso terapêutico , Prata/toxicidade , Infecção dos Ferimentos/terapia
18.
Life (Basel) ; 14(2)2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38398758

RESUMO

BACKGROUND: Bandages are commonly used to relieve pain in patients with plantar fasciitis. The goal was to compare the effects of using kinesiotape versus low-dye tape in the acute phase of plantar fasciitis on pain and comfort measures. METHODS: Forty individuals with plantar fasciitis were allocated to the kinesiotape or low-dye tape interventions. The patients were assessed at baseline and every 24 h until the fifth day. The primary measure was a visual analog scale of pain. The other measures were comfort, mobility, durability, personal hygiene, sweating, and allergies. The effects were compared with an ANOVA test, 95% CI. RESULTS: Kinesiotape was more effective in reducing pain; the greater effect occurred during the first day, with a between-group difference of 2.0 (95% CI: 1.8 to 2.2). The pain differences between the treatments progressively reduced each day from the second day. Kinesiotape offered significantly higher performance than low-dye tape in mobility, comfort, and comfort in hygiene, sweating, and durability, with a large effect size d > 0.8. CONCLUSIONS: Kinesiotape could be more effective than low-dye tape in relieving pain in patients with plantar fasciitis, with a significant clinical impact on the first day of treatment. Kinesiotape can also provide higher performance in terms of comfort.

19.
Actas Dermosifiliogr ; 115(7): 693-701, 2024.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38382747

RESUMO

The benefit of lower limb compression therapy is not limited to chronic venous insufficiency or/and lymphoedema. Thanks to its anti-edema and anti-inflammatory effects, compression therapy is considered a beneficial adjuvant therapy to treat atypical wounds, inflammatory dermatoses, cellulitis, and traumatic wounds in the absence of contraindications. Strict contraindications are limited to severe peripheral arterial disease and decompensated heart failure. The variability of commercially available compression materials and systems, such as short-stretch bandages, multi-component systems, zinc oxide bandages, medical adaptive compression systems, ulcer compression stockings or medical compression stockings, facilitates the adaptation of compression therapy to the individual needs of each patient. Compared to venous leg ulcers, low pressures of 20mmHg are often sufficient to treat dermatological disorders, with higher patient tolerance and compliance.


Assuntos
Bandagens Compressivas , Dermatologia , Humanos , Dermatologia/métodos , Meias de Compressão , Dermatopatias/terapia
20.
ACS Appl Mater Interfaces ; 16(4): 4307-4320, 2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38240181

RESUMO

Hemorrhage is the leading cause of trauma death, and innovation in hemostatic technology is important. The strongly hydrophobic carbon nanofiber (CNF) coating has previously been shown to have excellent hemostatic properties. However, the understanding of how CNF coating guides the coagulation cascade and the biosafety of CNF as hemostatic agents has yet to be explored. Here, our thrombin generation assay investigation showed that CNF induced fast blood coagulation via factor (F) XII activation of the intrinsic pathway. We further performed studies of a rat vein injury and demonstrated that the CNF gauze enabled a substantial reduction of blood loss compared to both the plain gauze and kaolin-imbued gauze (QuikClot). Analysis of blood samples from the model revealed no acute toxicity from the CNF gauze, with no detectable CNF deposition in any organ, suggesting that the immobilization of CNF on our gauze prevented the infiltration of CNF into the bloodstream. Direct injection of CNF into the rat vein was also investigated and found not to elicit overt acute toxicity or affect animal survival or behavior. Finally, toxicity assays with primary keratinocytes revealed minimal toxicity responses to CNF. Our studies thus supported the safety and efficacy of the CNF hemostatic gauze, highlighting its potential as a promising approach in the field of hemostatic control.


Assuntos
Hemorragia , Hemostáticos , Ratos , Animais , Hemorragia/prevenção & controle , Hemostáticos/farmacologia , Hemostáticos/uso terapêutico , Coagulação Sanguínea , Hemostasia , Interações Hidrofóbicas e Hidrofílicas , Modelos Animais de Doenças
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...