Resultados 1 - 20 de 203
Filtrar
1.
Neurospine ; 21(2): 606-619, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38955532

RESUMO

OBJECTIVE: Cervical hybrid surgery optimizes the use of cervical disc arthroplasty (CDA) and zero-profile (ZOP) devices in anterior cervical discectomy and fusion (ACDF) but lacks uniform combination and biomechanical standards, especially in revision surgery (RS). This study aimed to investigate the biomechanical characteristics of adjacent segments of the different hybrid RS constructs in ACDF RS. METHODS: An intact 3-dimensional finite element model generated a normal cervical spine (C2-T1). This model was modified to the primary C5-6 ACDF model. Three RS models were created to treat C4-5 adjacent segment degeneration through implanting cages plus plates (Cage-Cage), ZOP devices (ZOP-Cage), or Bryan discs (CDA-Cage). A 1.0-Nm moment was applied to the primary C5-6 ACDF model to generate total C2-T1 range of motions (ROMs). Subsequently, a displacement load was applied to all RS models to match the total C2-T1 ROMs of the primary ACDF model. RESULTS: The ZOP-Cage model showed lower biomechanical responses including ROM, intradiscal pressure, maximum von Mises stress in discs, and facet joint force in adjacent segments compared to the Cage-Cage model. The CDA-Cage model exhibited the lowest biomechanical responses and ROM ratio at adjacent segments among all RS models, closely approached or lower than those in the primary ACDF model in most motion directions. Additionally, the maximum von Mises stress on the C3-4 and C6-7 discs increased in the Cage-Cage and ZOP-Cage models but decreased in the CDA-Cage model when compared to the primary ACDF model. CONCLUSION: The CDA-Cage construct had the lowest biomechanical responses with minimal kinematic change of adjacent segments. ZOP-Cage is the next best choice, especially if CDA is not suitable. This study provides a biomechanical reference for clinical hybrid RS decision-making to reduce the risk of ASD recurrence.

2.
J Bodyw Mov Ther ; 39: 24-31, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38876633

RESUMO

BACKGROUND: Limited knowledge exists about the effectiveness of dry needling (DN) concerning the torso kinematics in patients with non-specific low back pain (NS-LBP). Acute effects of DN in NS-LBP patients from a functional perspective were investigated. METHODS: Sixteen NS-LBP patients and 11 healthy individuals (HG) were examined. NS-LBP patients received a single session of DN at the lumbar region. Baseline and immediate post-treatment measurements during flexion-extension and lateral bending of the trunk were conducted for the NS-LBP patients. HG were measured only at baseline to be used as a reference of NS-LBP patients' initial condition. Algometry was applied in NS-LBP patients. Centre of pressure, range of motion of the trunk and its' derivatives were obtained. FINDINGS: HG performed significantly faster, smoother and with greater mobility in the performed tasks compared to the pre intervention measurements of the NS-LBP patients. For the NS-LBP patients, significant greater angular velocity in frontal plane and significant lower jerk in the sagittal plane were demonstrated post intervention. DN alleviated pain tolerance significantly at the L5 level. Regarding the effectiveness of the DN upon spine kinematics, their derivatives were more sensitive. INTERPRETATION: It appeared that the pathological type of torso movement was acutely affected by DN. NS-LBP patients showcased smoother movement immediately after the intervention and better control as imprinted in the higher derivative of motion although range of motion did not improve. This quantitative variable may not be subjected to acute effects of DN but rather need additional time and training to be improved.


Assuntos
Agulhamento Seco , Dor Lombar , Amplitude de Movimento Articular , Tronco , Humanos , Dor Lombar/terapia , Dor Lombar/fisiopatologia , Fenômenos Biomecânicos , Masculino , Feminino , Adulto , Tronco/fisiologia , Tronco/fisiopatologia , Amplitude de Movimento Articular/fisiologia , Agulhamento Seco/métodos , Equilíbrio Postural/fisiologia , Pessoa de Meia-Idade
3.
Artigo em Inglês | MEDLINE | ID: mdl-38884654

RESUMO

PURPOSE: To evaluate the biomechanical and tomographic outcomes of keratoconus patients up to four years after corneal crosslinking (CXL). METHODS: In this longitudinal retrospective-prospective single-center case series, the preoperative tomographic and biomechanical results from 200 keratoconus eyes of 161 patients undergoing CXL were compared to follow-up examinations at three-months, six-months, one-year, two-years, three-years, and four-years after CXL. Primary outcomes included the Corvis Biomechanical Factor (CBiF) and five biomechanical response parameters obtained from the Corvis ST. Tomographically, the Belin-Ambrósio deviation index (BAD-D) and the maximal keratometry (Kmax) measured by the Pentacam were analyzed. Additionally, Corvis E-staging, the thinnest corneal thickness (TCT), and the best-corrected visual acuity (BCVA) were obtained. Primary outcomes were compared using a paired t-test. RESULTS: The CBiF decreased significantly at the six-month (p < 0.001) and one-year (p < 0.001) follow-ups when compared to preoperative values. E-staging behaved accordingly to the CBiF. Within the two- to four-year follow-ups, the biomechanical outcomes showed no significant differences when compared to preoperative. Tomographically, the BAD-D increased significantly during the first year after CXL with a maximum at six-months (p < 0.001), while Kmax decreased significantly (p < 0.001) and continuously up to four years after CXL. The TCT was lower at all postoperative follow-up visits compared to preoperative, and the BCVA improved. CONCLUSION: In the first year after CXL, there was a temporary progression in both the biomechanical CBiF and E-staging, as well as in the tomographic analysis. CXL contributes to the stabilization of both the tomographic and biomechanical properties of the cornea up to four years postoperatively.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38806750

RESUMO

This study aims to investigate the biomechanical behaviour and the stiffness impact of the breast internal components during running. To achieve this, a novel nonlinear multi-component dynamic finite element method (FEM) has been established, which uses experimental data obtained via 4D scanning technology and a motion capture system. The data are used to construct a geometric model that comprises the rigid body, layers of soft tissues, skin, pectoralis major muscle, fat, ligaments and glandular tissues. The traditional point-to-point method has a relative mean absolute error of less than 7.92% while the latest surface-to-surface method has an average Euclidean distance (d) of 7.05 mm, validating the simulated results. After simulating the motion of the different components of the breasts, the displacement analysis confirms that when the motion reaches the moment of largest displacement, the displacement of the breast components is proportional to their distance from the chest wall. A biomechanical analysis indicates that the stress sustained by the breast components in ascending order is the glandular tissues, pectoralis major muscle, adipose tissues, and ligaments. The ligaments provide the primary support during motion, followed by the pectoralis major muscle. In addition, specific stress points of the breast components are identified. The stiffness impact experiment indicates that compared with ligaments, the change of glandular tissue stiffness had a slightly more obvious effect on the breast surface. The findings serve as a valuable reference for the medical field and sports bra industry to enhance breast protection during motion.

5.
Artigo em Inglês | MEDLINE | ID: mdl-38695545

RESUMO

Advances in medical technology have enabled minimally invasive treatment of type A aortic dissection with accompanying aortic regurgitation. Implants include endovascular stent grafts (ESG) and heart valve substitute (HVS) modules. Traditional implants can be divided into two types based on the assembly relationship between ESG and HVS: separated z-shaped implants (SZ) and separated diamond-shaped implants (SD). This study proposes a novel linked diamond-shaped implant (LD). To evaluate the safety and effectiveness of this new implant, finite element simulation models were created to assess the risks of endoleak, migration, and vascular wall rupture under annulus displacement load. After the SZ, SD, and LD implants were grafted in virtual release method, all the implants can cover tear-entry located in the ascending aorta, but space distance (δ) which exposed to blood was 14.5, 13.1, and 7.4 mm, respectively; the maximum areas of contact gap was 76.5, 51.5 and 6.3 mm2; the maximum migration distance (ΔL1) were 1.27, 1.06, and 0.1 mm; the maximum stress on ascending aorta was 0.19, 0.24, and 0.51 MPa, which were lower than failure stress (0.9 MPa). This study showed that both SZ and SD implants had minimal effects on the ascending aorta; however, higher risks were associated with implant migration and proximal endoleak. In contrast, the LD implant can simplify the surgical procedure, has a lower risk of endoleak and migration, and limited stress stimulation of the aorta. This study validated the feasibility and effectiveness of this novel implant using the finite element method, indicating its potential as a secure and reliable treatment option.

6.
Sensors (Basel) ; 24(9)2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38732811

RESUMO

Rotational jumps are crucial techniques in sports competitions. Estimating ground reaction forces (GRFs), a constituting component of jumps, through a biomechanical model-based approach allows for analysis, even in environments where force plates or machine learning training data would be impossible. In this study, rotational jump movements involving twists on land were measured using inertial measurement units (IMUs), and GRFs and body loads were estimated using a 3D forward dynamics model. Our forward dynamics and optimization calculation-based estimation method generated and optimized body movements using cost functions defined by motion measurements and internal body loads. To reduce the influence of dynamic acceleration in the optimization calculation, we estimated the 3D orientation using sensor fusion, comprising acceleration and angular velocity data from IMUs and an extended Kalman filter. As a result, by generating cost function-based movements, we could calculate biomechanically valid GRFs while following the measured movements, even if not all joints were covered by IMUs. The estimation approach we developed in this study allows for measurement condition- or training data-independent 3D motion analysis.


Assuntos
Movimento , Esportes , Humanos , Movimento/fisiologia , Fenômenos Biomecânicos/fisiologia , Esportes/fisiologia , Aceleração , Masculino , Adulto , Algoritmos
7.
Sensors (Basel) ; 24(9)2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38732898

RESUMO

The biomechanical-model-based approach with a contact model offers advantages in estimating ground reaction forces (GRFs) and ground reaction moments (GRMs), as it does not rely on the need for training data and gait assumptions. However, this approach faces the challenge of long computational times due to the inclusion of optimization processes. To address this challenge, the present study developed a new optical motion capture (OMC)-based method to estimate GRFs, GRMs, and joint torques without prolonged computational times. The proposed approach performs the estimation process by distributing external forces, as determined by a multibody model, between the left and right feet based on foot deformations, thereby predicting the GRFs and GRMs without relying on optimization techniques. In this study, prediction accuracies during level walking were confirmed by comparing a general analysis using a force plate with the estimation results. The comparison revealed excellent or strong correlations between the prediction and the measurements for all GRFs, GRMs, and lower-limb-joint torques. The proposed method, which provides practical estimation with low computational cost, facilitates efficient biomechanical analysis and rapid feedback of analysis results, contributing to its increased applicability in clinical settings.

8.
Artigo em Inglês | MEDLINE | ID: mdl-38741377

RESUMO

PURPOSE: Derotational distal femoral osteotomy (DFO) is the causal treatment for patients with femoral torsional deformity. The fixation is achieved by a unilateral angle-stable plate. Delayed- or non-unions are one of the main risks of the procedure. An additional contralateral fixation may benefit the outcome. Therefore, we hypothesize that primary stability in DFO can be improved by an additional fixation with a hinge screw or an internal plate. METHODS: Derotational DFO was performed in 15 knees and fixed either with an angle-stable plate only (group 'None'), with an additional lateral screw (group 'Screw') or with an additional lateral plate (group 'Plate'). Biomechanical evaluation was carried out under axial loading of 150 N (partial weight bearing) and 800 N (full weight bearing), followed by internal and external rotation. After linear axial loading in step 1, a cyclic torsional load of 5 Nm was applied under constant axial load in step 2. In step 3, the specimens were unloaded. Micromovements between the distal and proximal parts of the osteotomy were recorded at each step for all specimens. RESULTS: In step 1, the extent of micromovements was highest in group 'None' and lowest in group 'Plate' without being significantly different. In step 2, group 'Plate' showed significantly higher stability, reflected by less rotation and lower micromovements. Increasing the axial load from 150 to 800 N at step 2 resulted in increased stability in all groups but only reached significance in group 'None'. CONCLUSION: An additional contralateral plate significantly increased stability in derotational DFO compared to the unilateral angle-stable plate only. Contrary, a contralateral hinge screw did not provide improved stability. STUDY DESIGN: Experimental study. LEVEL OF EVIDENCE: IV.

9.
Heliyon ; 10(7): e28606, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38571577

RESUMO

Hip fracture, increasing exponentially with age, is osteoporosis's most severe clinical consequence. Intertrochanteric fracture, one of the main types of hip fracture, is associated with higher mortality and morbidity. The current research hotspots lay in improving the treatment effect and optimizing the secondary stability after intertrochanteric fracture surgery. Cortex buttress reduction is a widely accepted method for treating intertrochanteric fracture by allowing the head-neck fragment to slide and rigidly contact the femoral shaft's cortex. Medial cortical support is considered a more effective option in treating young patients. However, osteo-degenerations features, including bone weakness and cortical thickness thinning, affect the performance of cortex support in geriatric intertrochanteric fracture treatment. Literature focusing on the age-specific difference in cortex performance in the fractured hip is scarce. We hypothesized that this osteo-19 degenerative feature affects the performance of cortex support in treating intertrochanteric fractures between the young and the elderly. We established twenty models for the old and the young with intertrochanteric fractures and performed static and dynamic simulations under one-legged stance and walking cycle conditions. The von Mises stress and displacement on the femur, proximal femoral nail anti-rotation (PFNA) implant, fracture plane, and the cutting volume of cancellous bone of the femur were compared. It was observed that defects in the anterior and posterior cortical bone walls significantly increase the stress on the PFNA implant, the displacement of the fracture surface, and cause a greater volume of cancellous bone to be resected. We concluded that ensuring the integrity and alignment of the anterior and posterior cortical bones is essential for elderly patients, and sagittal support is recommended. This finding suggests that the treatment method for intertrochanteric fracture may differ, considering the patient's age difference.

10.
Materials (Basel) ; 17(7)2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38612211

RESUMO

The damping system ensured by the osteochondral (OC) unit is essential to deploy the forces generated within load-bearing joints during locomotion, allowing furthermore low-friction sliding motion between bone segments. The OC unit is a multi-layer structure including articular cartilage, as well as subchondral and trabecular bone. The interplay between the OC tissues is essential in maintaining the joint functionality; altered loading patterns can trigger biological processes that could lead to degenerative joint diseases like osteoarthritis. Currently, no effective treatments are available to avoid degeneration beyond tissues' recovery capabilities. A thorough comprehension on the mechanical behaviour of the OC unit is essential to (i) soundly elucidate its overall response to intra-articular loads for developing diagnostic tools capable of detecting non-physiological strain levels, (ii) properly evaluate the efficacy of innovative treatments in restoring physiological strain levels, and (iii) optimize regenerative medicine approaches as potential and less-invasive alternatives to arthroplasty when irreversible damage has occurred. Therefore, the leading aim of this review was to provide an overview of the state-of-the-art-up to 2022-about the mechanical behaviour of the OC unit. A systematic search is performed, according to PRISMA standards, by focusing on studies that experimentally assess the human lower-limb joints' OC tissues. A multi-criteria decision-making method is proposed to quantitatively evaluate eligible studies, in order to highlight only the insights retrieved through sound and robust approaches. This review revealed that studies on human lower limbs are focusing on the knee and articular cartilage, while hip and trabecular bone studies are declining, and the ankle and subchondral bone are poorly investigated. Compression and indentation are the most common experimental techniques studying the mechanical behaviour of the OC tissues, with indentation also being able to provide information at the micro- and nanoscales. While a certain comparability among studies was highlighted, none of the identified testing protocols are currently recognised as standard for any of the OC tissues. The fibril-network-reinforced poro-viscoelastic constitutive model has become common for describing the response of the articular cartilage, while the models describing the mechanical behaviour of mineralised tissues are usually simpler (i.e., linear elastic, elasto-plastic). Most advanced studies have tested and modelled multiple tissues of the same OC unit but have done so individually rather than through integrated approaches. Therefore, efforts should be made in simultaneously evaluating the comprehensive response of the OC unit to intra-articular loads and the interplay between the OC tissues. In this regard, a multidisciplinary approach combining complementary techniques, e.g., full-field imaging, mechanical testing, and computational approaches, should be implemented and validated. Furthermore, the next challenge entails transferring this assessment to a non-invasive approach, allowing its application in vivo, in order to increase its diagnostic and prognostic potential.

11.
JMIR Res Protoc ; 13: e52365, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38564249

RESUMO

BACKGROUND: Ankle-foot orthoses (AFOs) are vital in gait rehabilitation for patients with stroke. However, many conventional AFO designs may not offer the required precision for optimized patient outcomes. With the advent of 3D scanning and printing technology, there is potential for more individualized AFO solutions, aiming to enhance the rehabilitative process. OBJECTIVE: This nonrandomized trial seeks to introduce and validate a novel system for AFO design tailored to patients with stroke. By leveraging the capabilities of 3D scanning and bespoke software solutions, the aim is to produce orthoses that might surpass conventional designs in terms of biomechanical effectiveness and patient satisfaction. METHODS: A distinctive 3D scanner, complemented by specialized software, will be developed to accurately capture the biomechanical data of leg movements during gait in patients with stroke. The acquired data will subsequently guide the creation of patient-specific AFO designs. These personalized orthoses will be provided to participants, and their efficacy will be compared with traditional AFO models. The qualitative dimensions of this experience will be evaluated using the Quebec User Evaluation of Satisfaction With Assistive Technology (QUEST) assessment tool. Feedback from health care professionals and the participants will be considered throughout the trial to ensure a rounded understanding of the system's implications. RESULTS: Spatial-temporal parameters will be statistically compared using paired t tests to determine significant differences between walking with the personalized orthosis, the existing orthosis, and barefoot conditions. Significant differences will be identified based on P values, with P<.05 indicating statistical significance. The Statistical Parametric Mapping method will be applied to graphically compare kinematic and kinetic data across the entire gait cycle. QUEST responses will undergo statistical analysis to evaluate patient satisfaction, with scores ranging from 1 (not satisfied) to 5 (very satisfied). Satisfaction scores will be presented as mean and SD values. Significant variations in satisfaction levels between the personalized and existing orthosis will be assessed using a Wilcoxon signed rank test. The anticipation is that the AFOs crafted through this innovative system will either match or outperform existing orthoses in use, with higher patient satisfaction rates. CONCLUSIONS: Embracing the synergy of technology and biomechanics may hold the key to revolutionizing orthotic design, with the potential to set new standards in patient-centered orthotic solutions. However, as with all innovations, a balanced approach, considering both the technological possibilities and individual patient needs, will be paramount to achieving optimal outcomes. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): PRR1-10.2196/52365.

13.
Front Aging Neurosci ; 16: 1327397, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38371400

RESUMO

The cable-driven exoskeleton can avoid joint misalignment, and is substantial alterations in the pattern of muscle synergy coordination, which arouse more attention in recent years to facilitate exercise for older adults and improve their overall quality of life. This study leverages principles from neuroscience and biomechanical analysis to select attachment points for cable-driven soft exoskeletons. By extracting key features of human movement, the objective is to develop a subject-specific design methodology that provides precise and personalized support in the attachment points optimization of cable-driven exoskeleton to achieve natural gait, energy efficiency, and muscle coordination controllable in the domain of human mobility and rehabilitation. To achieve this, the study first analyzes human walking experimental data and extracts biomechanical features. These features are then used to generate trajectories, allowing better natural movement under complete cable-driven exoskeleton control. Next, a genetic algorithm-based method is employed to minimize energy consumption and optimize the attachment points of the cable-driven system. This process identifies connections that are better suited for the human model, leading to improved efficiency and natural movement. By comparing the calculated elderly human model driven by exoskeleton with experimental subject in terms of joint angles, joint torques and muscle forces, the human model can successfully replicate subject movement and the cable output forces can mimic human muscle coordination. The optimized cable attachment points facilitate more natural and efficient collaboration between humans and the exoskeleton, making significant contributions to the field of assisting the elderly in rehabilitation.

14.
Quant Imaging Med Surg ; 14(2): 1477-1492, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38415169

RESUMO

Background: It has been suggested that biomechanical factors may influence plaque development. However, key determinants for assessing plaque vulnerability remain speculative. Methods: In this study, a two-dimensional (2D) structural mechanical analysis and a three-dimensional (3D) fluid-structure interaction (FSI) analysis were conducted based on intravascular optical coherence tomography (IV-OCT) and digital subtraction angiography (DSA) data sets. In the 2D study, 103 IV-OCT slices were analyzed. An in-depth morpho-mechanic analysis and a weighted least absolute shrinkage and selection operator (LASSO) regression analysis were conducted to identify the crucial features related to plaque vulnerability via the tuning parameter (λ). In the 3D study, the coronary model was reconstructed by fusing the IV-OCT and DSA data, and a FSI analysis was subsequently performed. The relationship between vulnerable plaque and wall shear stress (WSS) was investigated. Results: The influential factors were selected using the minimum criteria (λ-min) and one-standard error criteria (λ-1se). In addition to the common vulnerable factor of the minimum fibrous cap thickness (FCTmin), four biomechanical factors were selected by λ-min, including the average/maximal displacements and average/maximal stress, and two biomechanical factors were selected by λ-1se, including the average/maximal displacements. Additionally, the positions of the vulnerable plaques were consistent with the sites of high WSS. Conclusions: Functional indices are crucial for plaque status assessment. An evaluation based on biomechanical simulations might provide insights into risk identification and guide therapeutic decisions.

15.
Eur Spine J ; 33(4): 1332-1339, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38172415

RESUMO

PURPOSE: The occurrence of an iatrogenic vertebral fracture during non-spinal digestive surgery is an exceptional event that has not been previously documented. Our study aims to explain the occurrence of this fracture from a biomechanical perspective, given its rarity. Using a finite element model of the spine, we will evaluate the strength required to induce a vertebral fracture through a hyperextension mechanism, considering the structure of the patient's spine, whether it is ossified or healthy. METHODS: A 70-year-old patient was diagnosed T12 fracture during a liver transplantation on ankylosed spine. We use a finite element model of the spine. Different mechanical properties were applied to the spine model: first to a healthy spine, the second to a osteoporotic ossified spine. The displacement and force imposed at the Sacrum, the time and location of fractures initiation were recorded and compared between the two spine conditions. RESULTS: A surgical treatment is done associating decompression with posterior fixation. After biomechanical study, we found that the fracture initiation occurred for the ossified spine after a sacrum displacement of 29 mm corresponding to an applied force of 65 N. For the healthy spine it occurred at a sacrum displacement of 52 mm corresponding to an applied force of 350 N. CONCLUSION: The force required to produce a type B fracture in an ankylosed spine is 5 times less than in a healthy spine. These data enable us to propose several points of management to avoid unexpected complications with ankylosed spines during surgical procedures. LEVEL OF EVIDENCE: IV.


Assuntos
Transplante de Fígado , Fraturas da Coluna Vertebral , Humanos , Idoso , Fraturas da Coluna Vertebral/complicações , Fraturas da Coluna Vertebral/diagnóstico por imagem , Análise de Elementos Finitos , Transplante de Fígado/efeitos adversos , Sacro , Doença Iatrogênica/prevenção & controle , Fenômenos Biomecânicos
16.
Injury ; 55(3): 111316, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38215570

RESUMO

This study aims to compare the mechanical strength of three different posterior-based internal fixation methods for posteromedial tibial plateau fractures. The study utilized 12 tibial plateaus harvested from fresh-frozen cadavers, and the posteromedial fracture fragments were created. The bones were then randomly assigned to one of three fixation methods: two posteroanterior lag screws (LS) size 4.0 mm, posterior buttress plate using a 3.5 mm small dynamic compression plate (DCP), or posterior buttress plate using a 3.5 mm T-shaped plate (TP). Biomechanical testing was performed by applying vertical compression force to the center of the posteromedial fracture fragment until the load to failure (displacement ≥ 3 mm) was reached, and displacement of the fragment was measured using a motion sensor. The data exhibited normal distribution, and one-way analysis of variance (ANOVA) was used to determine the load to failure, followed by Fisher post hoc Least-Significant Difference (LSD) to correct for multiple comparisons. The statistical analysis demonstrated significantly higher mean load to failure values in the T-shaped plate group compared to both the small dynamic compression plate group and the lag screw group (p < 0.05). However, after conducting further post hoc analysis, the observed significant differences were solely between the LS and TP groups (p = 0.021). These findings suggest that the T-shaped plate represents the most effective method for internally fixing posteromedial tibial plateau fractures.


Assuntos
Fraturas da Tíbia , Fraturas do Planalto Tibial , Humanos , Fenômenos Biomecânicos , Parafusos Ósseos , Fraturas da Tíbia/cirurgia , Fixação Interna de Fraturas/métodos , Placas Ósseas , Cadáver
17.
Folia Phoniatr Logop ; 76(1): 91-101, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37499642

RESUMO

INTRODUCTION: Previous research on voice in Parkinson's disease (PD) has consistently demonstrated alterations in acoustic parameters, including fundamental frequency (F0), maximum phonation time, Shimmer, and Jitter. However, investigations into acoustic parameter alterations in individuals with PD are limited. METHODS: We conducted an experimental study involving 20 PD patients (six women and fourteen men). Subjective measures of voice (VHI-30 scale and GRBAS) and objective measures using the OnlineLAB App tool for analyzing biomechanical correlates of voice were recorded. The app analyzed a total of 22 biomechanical parameters of voice. RESULTS: The results of subjective measures were consistent with findings from previous studies. However, the results of objective measures did not align with studies that employed acoustic measures. CONCLUSIONS: The biomechanical analysis revealed alterations in various parameters according to gender. These findings open up a new avenue of research in voice analysis for patients with PD, whether through acoustic or biomechanical analysis, aiming to determine whether the observed changes in these patients' voices are attributable to age or disease progression. This line of investigation will help elucidate the relative contribution of these factors to vocal alterations in PD patients and provide a more comprehensive understanding of the underlying mechanisms.


Assuntos
Doença de Parkinson , Distúrbios da Voz , Voz , Masculino , Humanos , Feminino , Doença de Parkinson/complicações , Qualidade da Voz , Fonação , Acústica da Fala , Distúrbios da Voz/etiologia
18.
Ann Biomed Eng ; 52(2): 386-395, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37864043

RESUMO

Congenital heart disease (CHD) accounts for nearly one-third of all congenital defects, and patients often require repeated heart valve replacements throughout their lives, due to failed surgical repairs and lack of durability of bioprosthetic valve implants. This objective of this study is to develop and in vitro test a fetal transcatheter pulmonary valve replacement (FTPVR) using sutureless techniques to attach leaflets, as an option to correct congenital defects such as pulmonary atresia with intact ventricular septum (PA/IVS), in utero. A balloon expandable design was analyzed using computational simulations to identify areas of failure. Five manufactured valves were assembled using the unique sutureless approach and tested in the fetal right heart simulator (FRHS) to evaluate hemodynamic characteristics. Computational simulations showed that the commissural loads on the leaflet material were significantly reduced by changing the attachment techniques. Hemodynamic analysis showed an effective orifice area of 0.08 cm2, a mean transvalvular pressure gradient of 7.52 mmHg, and a regurgitation fraction of 8.42%, calculated over 100 consecutive cardiac cycles. In conclusion, the FTPVR exhibited good hemodynamic characteristics, and studies with biodegradable stent materials are underway.


Assuntos
Próteses Valvulares Cardíacas , Poliésteres , Atresia Pulmonar , Substituição da Valva Aórtica Transcateter , Humanos , Atresia Pulmonar/cirurgia , Coração Fetal , Desenho de Prótese , Valva Aórtica , Resultado do Tratamento
19.
Appl Physiol Nutr Metab ; 49(2): 213-222, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37820387

RESUMO

We have studied the effects of individual and combined treatment of insulin (I) and naringin (NAR) on the bone structure and biomechanical properties of femurs from streptozotocin (STZ)-induced diabetic rats. Male Wistar rats were divided into five groups: (1) controls, (2) STZ-induced diabetic rats, (3) STZ-induced diabetic rats treated with I, (4) STZ-induced diabetic rats treated with NAR, and (5) STZ-induced diabetic rats treated with I + NAR. Bone mineral density (BMD), bone histomorphometry, biomechanical testing, and bone biomarker expressions were accomplished in femur of all animals, as well as serum biochemical analyses. The combined treatment of I + NAR increased the body weight and the femur BMD from STZ-induced diabetic rats. The bone biomechanical properties and the bone morphology of the femurs from STZ-induced diabetic rats were also improved by the combined treatment. The increased number of osteoclasts in STZ-induced diabetic rats was partially prevented by I, NAR, or I + NAR. NAR or I + NAR completely blocked the decrease in the number of osteocalcin (+) cells in the femur from STZ-induced diabetic rats. RUNX family transcription factor 2 immunostaining was much lower in STZ-induced diabetic rats than in control animals; the combination of I + NAR totally blocked this effect. The combined treatment not only ameliorated bone quality and function, but also normalized the variables related to glucose metabolism. Therefore, the combination of I + NAR might be a better therapeutic strategy than the individual I or NAR administration to reduce bone complications in diabetic patients.


Assuntos
Diabetes Mellitus Experimental , Diabetes Mellitus Tipo 1 , Flavanonas , Humanos , Ratos , Masculino , Animais , Diabetes Mellitus Tipo 1/complicações , Insulina , Ratos Wistar , Diabetes Mellitus Experimental/complicações , Densidade Óssea
20.
J Shoulder Elbow Surg ; 33(1): 145-155, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37689102

RESUMO

BACKGROUND: Overloading of the elbow joint prosthesis following total elbow arthroplasty can lead to implant failure. Joint moments during daily activities are not well contextualized for a prosthesis's failure limits, and the effect of the current postoperative instruction on elbow joint loading is unclear. This study investigates the difference in elbow joint moments between simulated daily tasks and between flexion-extension, pronation-supination, and varus-valgus movement directions. Additionally, the effect of the current postoperative instruction on elbow joint load is examined. METHODS: Nine healthy participants (age 45.8 ± 17 years, 3 males) performed 8 tasks; driving a car, opening a door, rising from a chair, lifting, sliding, combing hair, drinking, emptying cup, without and with the instruction "not lifting more than 1 kg." Upper limb kinematics and hand contact forces were measured. Elbow joint angles and net moments were analyzed using inverse dynamic analysis, where the net moments are estimated from movement data and external forces. RESULTS: Peak elbow joint moments differed significantly between tasks (P < .01) and movement directions (P < .01). The most and least demanding tasks were, rising from a chair (13.4 Nm extension, 5.0 Nm supination, and 15.2 Nm valgus) and sliding (4.3 Nm flexion, 1.7 Nm supination, and 2.6 Nm varus). Net moments were significantly reduced after instruction only in the chair task (P < .01). CONCLUSION: This study analyzed elbow joint moments in different directions during daily tasks. The outcomes question whether postoperative instruction can lead to decreasing elbow loads. Future research might focus on reducing elbow loads in the flexion-extension and varus-valgus directions.


Assuntos
Artroplastia de Substituição do Cotovelo , Articulação do Cotovelo , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Articulação do Cotovelo/cirurgia , Cotovelo , Atividades Cotidianas , Movimento , Fenômenos Biomecânicos