Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 223
Filtrar
1.
Front Neurol ; 15: 1417788, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38841699

RESUMO

Background: Although sclerotherapy is widely used to treat vascular malformations (VMs), it is associated with several challenges. One significant issue is the insufficient understanding of the influence of various factors on the stability of polidocanol (POL) foam used in sclerotherapy. Objective: This study aimed to explore the effect of the catheter needle caliber on foam stability when using POL with or without hyaluronic acid (HA) for the treatment of VMs. Methods and materials: The Tessari method generated sclerosant foam using POL both with and without HA. We used catheters and syringe needles of various calibers, and the resulting foam was transferred into new syringes to facilitate a comparison of foam stability. Foam half-life (FHT) was utilized as a metric to assess foam stability. Results: The study found that narrower needle calibers produced a more stable foam when POL was used alone; however, no significant effect was observed when HA was added. Furthermore, when the foam was expelled using catheters and syringe needles of the same size, no noticeable changes in the stability were observed. Conclusion: When choosing needles of varying calibers, their effect on foam stability should be carefully considered, particularly when the foam contains HA.

2.
Cureus ; 16(4): e57559, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38707083

RESUMO

Introduction The rarity in detecting female urethral stricture (FUS) backed by the inconsistency regarding the cutoff on the caliber to direct any treatment for its increase poses a challenge to its existence. Therefore, the present study was conducted to determine the caliber of the urethra that clearly identifies a FUS. Materials and method In this prospective observational study conducted between November 2015 and July 2017, women with obstructive lower urinary tract symptoms (LUTS) and a history of relief on at least a single urethral dilatation were included if the American Urological Association (AUA) score was more than seven and the maximum flow rate (Qmax) was less than 20 mL/sec. Of the 71 women recruited, 10 women had recognizable external causes: caruncle (five), mucosal prolapse (three), and meatal stenosis (two). The remaining 61 underwent voiding cystourethrogram (VCUG) and urodynamics followed by urethrocystoscopy, if the findings suggested a stricture. A definitive diagnosis was sought in those without stricture disease. We categorized all patients as either having a "true" stricture or an alternate etiology. Categorical variables were presented in number and percentage (%) and continuous variables as mean ± standard deviation (SD). Results The mean dilatation ranged between one and six; the mean AUA score, ~17.82 ± 3.59; mean Qmax, ~10.21 ± 3.39 mL/sec; and the mean post-void residue (PVR), 106.65 ± 51 mL. A total of 29 patients were diagnosed to have stricture (dense = 17; flimsy = 12). None of the patients in this group had a urethral caliber of more than 14 French (Fr). Other etiologies were dysfunctional voiding (17), underactive bladder (seven), cystocele (four), and primary bladder neck obstruction (PBNO) (four). Conclusion Women with voiding LUTS should be screened for FUS only if the urethral caliber is ≤14 Fr.

3.
J Agric Food Chem ; 72(20): 11597-11605, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38718203

RESUMO

The aim of the study was to investigate how smoke-associated flavoring substances behave during storage in Frankfurter-type sausages. The diffusion behavior of seven selected aroma substances in the sausage matrix and the influence of the packaging and the casing were examined over a storage period of 28 days. The sausages were cut into uniformly thick layers at defined time intervals and examined by headspace-solid phase microextraction-gas chromatography-mass spectrometry. In general, three different groups could be distinguished: (1) even distribution over the entire product on the first day after smoking; (2) clear concentration gradient from outside to inside on the first day of storage, which leveled out until day 28 of storage; and (3) a clear concentration gradient that remained present throughout the storage period. In addition, only small effects were found in the distribution of flavorings between two types of packaging, selected casing, or different calibers.


Assuntos
Aromatizantes , Embalagem de Alimentos , Cromatografia Gasosa-Espectrometria de Massas , Produtos da Carne , Odorantes , Fumaça , Embalagem de Alimentos/instrumentação , Fumaça/análise , Produtos da Carne/análise , Odorantes/análise , Animais , Aromatizantes/química , Suínos , Microextração em Fase Sólida , Compostos Orgânicos Voláteis/química , Difusão , Armazenamento de Alimentos
4.
Front Bioeng Biotechnol ; 12: 1352387, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38419729

RESUMO

Mild traumatic brain injury (mTBI) may be caused by occupational hazards military personnel encounter, such as falls, shocks, exposure to blast overpressure events, and recoil from weapon firing. While it is important to protect against injurious head impacts, the repeated exposure of Canadian Armed Forces (CAF) service members to sub-concussive events during the course of their service may lead to a significant reduction in quality of life. Symptoms may include headaches, difficulty concentrating, and noise sensitivity, impacting how personnel complete their duties and causing chronic health issues. This study investigates how the exposure to the recoil force of long-range rifles results in head motion and brain deformation. Direct measurements of head kinematics of a controlled population of military personnel during firing events were obtained using instrumented mouthguards. The experimentally measured head kinematics were then used as inputs to a finite element (FE) head model to quantify the brain strains observed during each firing event. The efficacy of a concept recoil mitigation system (RMS), designed to mitigate loads applied to the operators was quantified, and the RMS resulted in lower loading to the operators. The outcomes of this study provide valuable insights into the magnitudes of head kinematics observed when firing long-range rifles, and a methodology to quantify effects, which in turn will help craft exposure guidelines, guide training to mitigate the risk of injury, and improve the quality of lives of current and future CAF service members and veterans.

5.
Curr Eye Res ; 49(6): 639-649, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38407139

RESUMO

PURPOSE: To develop a highly efficient and fully automated method that measures retinal vessel caliber using digital retinal photographs and evaluate the association between retinal vessel caliber and hypertension. METHODS: The subjects of this study were from two sources in Beijing, China, a hypertension case-control study from Tongren Hospital (Tongren study) and a community-based atherosclerosis cohort from Peking University First Hospital (Shougang study). Retinal vessel segmentation and arteriovenous classification were achieved simultaneously by a customized deep learning model. Two experienced ophthalmologists evaluated whether retinal vessels were correctly segmented and classified. The ratio of incorrectly segmented and classified retinal vessels was used to measure the accuracy of the model's recognition. Central retinal artery equivalents, central retinal vein equivalents and arteriolar-to-venular diameter ratio were computed to analyze the association between retinal vessel caliber and the risk of hypertension. The association was then compared to that derived from the widely used semi-automated software (Integrative Vessel Analysis). RESULTS: The deep learning model achieved an arterial recognition error rate of 1.26%, a vein recognition error rate of 0.79%, and a total error rate of 1.03%. Central retinal artery equivalents and arteriolar-to-venular diameter ratio measured by both Integrative Vessel Analysis and deep learning methods were inversely associated with the odds of hypertension in both Tongren and Shougang studies. The comparisons of areas under the receiver operating characteristic curves from the proposed deep learning method and Integrative Vessel Analysis were all not significantly different (p > .05). CONCLUSION: The proposed deep learning method showed a comparable diagnostic value to Integrative Vessel Analysis software. Compared with semi-automatic software, our deep learning model has significant advantage in efficiency and can be applied to population screening and risk evaluation.


Assuntos
Aprendizado Profundo , Hipertensão , Vasos Retinianos , Humanos , Feminino , Hipertensão/diagnóstico , Hipertensão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Vasos Retinianos/patologia , Vasos Retinianos/diagnóstico por imagem , Estudos de Casos e Controles , Idoso , Pressão Sanguínea/fisiologia , Curva ROC
6.
J Appl Physiol (1985) ; 136(5): 1144-1156, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38420676

RESUMO

Smaller mean airway tree caliber is associated with airflow obstruction and chronic obstructive pulmonary disease (COPD). We investigated whether airway tree caliber heterogeneity was associated with airflow obstruction and COPD. Two community-based cohorts (MESA Lung, CanCOLD) and a longitudinal case-control study of COPD (SPIROMICS) performed spirometry and computed tomography measurements of airway lumen diameters at standard anatomical locations (trachea-to-subsegments) and total lung volume. Percent-predicted airway lumen diameters were calculated using sex-specific reference equations accounting for age, height, and lung volume. The association of airway tree caliber heterogeneity, quantified as the standard deviation (SD) of percent-predicted airway lumen diameters, with baseline forced expired volume in 1-second (FEV1), FEV1/forced vital capacity (FEV1/FVC) and COPD, as well as longitudinal spirometry, were assessed using regression models adjusted for age, sex, height, race-ethnicity, and mean airway tree caliber. Among 2,505 MESA Lung participants (means ± SD age: 69 ± 9 yr; 53% female, mean airway tree caliber: 99 ± 10% predicted, airway tree caliber heterogeneity: 14 ± 5%; median follow-up: 6.1 yr), participants in the highest quartile of airway tree caliber heterogeneity exhibited lower FEV1 (adjusted mean difference: -125 mL, 95%CI: -171,-79), lower FEV1/FVC (adjusted mean difference: -0.01, 95%CI: -0.02,-0.01), and higher odds of COPD (adjusted odds ratio: 1.42, 95%CI: 1.01-2.02) when compared with the lowest quartile, whereas longitudinal changes in FEV1 and FEV1/FVC did not differ significantly. Observations in CanCOLD and SPIROMICS were consistent. Among older adults, airway tree caliber heterogeneity was associated with airflow obstruction and COPD at baseline but was not associated with longitudinal changes in spirometry.NEW & NOTEWORTHY In this study, by leveraging two community-based samples and a case-control study of heavy smokers, we show that among older adults, airway tree caliber heterogeneity quantified by CT is associated with airflow obstruction and COPD independent of age, sex, height, race-ethnicity, and dysanapsis. These observations suggest that airway tree caliber heterogeneity is a structural trait associated with low baseline lung function and normal decline trajectory that is relevant to COPD.


Assuntos
Pulmão , Doença Pulmonar Obstrutiva Crônica , Espirometria , Humanos , Feminino , Masculino , Idoso , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Espirometria/métodos , Pulmão/fisiopatologia , Pulmão/diagnóstico por imagem , Volume Expiratório Forçado/fisiologia , Estudos de Casos e Controles , Capacidade Vital/fisiologia , Pessoa de Meia-Idade , Estudos Longitudinais , Tomografia Computadorizada por Raios X/métodos , Obstrução das Vias Respiratórias/fisiopatologia , Idoso de 80 Anos ou mais
7.
bioRxiv ; 2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38328196

RESUMO

The cardiovascular system generates and responds to mechanical forces. The heartbeat pumps blood through a network of vascular tubes, which adjust their caliber in response to the hemodynamic environment. However, how endothelial cells in the developing vascular system integrate inputs from circulatory forces into signaling pathways to define vessel caliber is poorly understood. Using vertebrate embryos and in vitro-assembled microvascular networks of human endothelial cells as models, flow and genetic manipulations, and custom software, we reveal that Plexin-D1, an endothelial Semaphorin receptor critical for angiogenic guidance, employs its mechanosensing activity to serve as a crucial positive regulator of the Dorsal Aorta's (DA) caliber. We also uncover that the flow-responsive transcription factor KLF2 acts as a paramount mechanosensitive effector of Plexin-D1 that enlarges endothelial cells to widen the vessel. These findings illuminate the molecular and cellular mechanisms orchestrating the interplay between cardiovascular development and hemodynamic forces.

8.
Eur J Clin Invest ; 54(5): e14154, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38217524

RESUMO

BACKGROUND: We investigated the association between atrial fibrillation (AF) and dementia, and its subtypes (vascular-VaD, Alzheimer, mixed and rare dementia), and identified predictors for dementia in AF patients. METHODS: The analysis was based on 183,610 patients with new-onset AF and 367,220 non-AF controls in the United Kingdom between 1998 and 2016, identified in three prospectively collected, linked electronic health records sources. Time-to-event (dementia or subtypes) analyses were performed using Cox proportional hazards and weighted Cox. Sub-analyses performed: including & censoring stroke and age (median used as cut-off). RESULTS: Over a median follow-up of 2.67 years (IQR .65-6.02) for AF patients and 5.84 years for non-AF patients (IQR 2.26-11.80), incidence of dementia in the AF cohort was 2.65 per 100 person-years, compared to 2.02 in the non-AF cohort. After adjustment, a significant association was observed between AF and all-cause dementia (HR = 1.38, 95% CI: 1.31-1.45), driven by a strong association with VaD (HR = 1.55, 95% CI: 1.41-1.70). AF was also associated with mixed dementia (HR = 1.26, 95% CI: 1.01-1.56), but we could not confirm an association with Alzheimer (HR = 1.05, 95% CI: .94-1.16) and rare dementia forms (HR = 1.19, 95% CI: .90-1.56). Ischemic stroke (HR = 1.40, 95% CI: 1.26-1.56), subarachnoid haemorrhage (HR = 2.08, 95% CI: 1.47-2.96), intracerebral haemorrhage (HR = 1.95, 95% CI: 1.54-2.48) and diabetes (HR = 1.32, 95% CI: 1.24-1.41) were identified as the strongest predictors of dementia in AF patients. CONCLUSIONS: AF patients have an increased risk of dementia, independent of stroke, with highest risk of VaD. Management and prevention of the identified risk factors could be crucial to reduce the increasing burden of dementia.


Assuntos
Doença de Alzheimer , Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Estudos de Coortes , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/complicações , Registros Eletrônicos de Saúde , Acidente Vascular Cerebral/etiologia , Fatores de Risco , Incidência
9.
NMR Biomed ; 37(4): e5087, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38168082

RESUMO

The increasing availability of high-performance gradient systems in human MRI scanners has generated great interest in diffusion microstructural imaging applications such as axonal diameter mapping. Practically, sensitivity to axon diameter in diffusion MRI is attained at strong diffusion weightings b , where the deviation from the expected 1 / b scaling in white matter yields a finite transverse diffusivity, which is then translated into an axon diameter estimate. While axons are usually modeled as perfectly straight, impermeable cylinders, local variations in diameter (caliber variation or beading) and direction (undulation) are known to influence axonal diameter estimates and have been observed in microscopy data of human axons. In this study, we performed Monte Carlo simulations of diffusion in axons reconstructed from three-dimensional electron microscopy of a human temporal lobe specimen using simulated sequence parameters matched to the maximal gradient strength of the next-generation Connectome 2.0 human MRI scanner ( ≲ 500 mT/m). We show that axon diameter estimation is accurate for nonbeaded, nonundulating fibers; however, in fibers with caliber variations and undulations, the axon diameter is heavily underestimated due to caliber variations, and this effect overshadows the known overestimation of the axon diameter due to undulations. This unexpected underestimation may originate from variations in the coarse-grained axial diffusivity due to caliber variations. Given that increased axonal beading and undulations have been observed in pathological tissues, such as traumatic brain injury and ischemia, the interpretation of axon diameter alterations in pathology may be significantly confounded.


Assuntos
Imagem de Difusão por Ressonância Magnética , Substância Branca , Humanos , Imagem de Difusão por Ressonância Magnética/métodos , Axônios/patologia , Imageamento por Ressonância Magnética , Microscopia Eletrônica
10.
J Neuroradiol ; 51(2): 214-219, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37625629

RESUMO

Transradial access during neurointerventions has increased in popularity because of reduced complications and patient preference. Nevertheless, transradial cannulation into the left common carotid artery can be difficult technically because of the lack of catheter support in the aortic arch. Furthermore, the use of large sheaths can increase the risk of complications at the access site. Here, we developed a new very-small-bore transradial system using a 3F Simmons guiding sheath, to increase the procedural success rate and minimize access-site complications. This system can represent a valuable treatment option for neurointerventions and has the potential to expand the indications for transradial access.


Assuntos
Estenose das Carótidas , Artéria Radial , Humanos , Artéria Radial/cirurgia , Estenose das Carótidas/terapia , Artéria Carótida Primitiva , Cateterismo , Catéteres , Resultado do Tratamento
11.
Graefes Arch Clin Exp Ophthalmol ; 262(5): 1397-1407, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37682335

RESUMO

PURPOSE: To review the effects of firsthand tobacco smoking on central retinal arteriolar equivalent (CRAE) and central retinal venular equivalent (CRVE) of firsthand tobacco smokers. METHODS: We performed a search on EMBASE and PubMed for studies up to 15th July 2022. Two independent reviewers selected studies with baseline data of CRAE and CRVE of current smokers, nonsmokers, and former smokers. Initial search identified 893 studies, of which 10 were included in the meta-analysis. Two independent reviewers extracted data from the included studies. The quality of studies was assessed by the Newcastle-Ottawa Scale. RESULTS: In this meta-analysis, 7431 nonsmokers, 2448 current smokers and 5786 former smokers, as well as 7404 nonsmokers, 2430 current smokers and 5763 former smokers were included in CRAE and CRVE analysis respectively. Nonsmokers had narrower CRVE (Weighted mean difference [WMD], -12.15; 95% CI, -17.33 - -6.96) and CRAE (WMD, -4.77; 95% CI, -7.96 - -1.57) than current smokers, and narrower CRVE (WMD, -3.08; 95% CI, -6.06 - -0.11) than former smokers. Current smokers had wider CRVE (WMD, 10.42; 95% CI, 7.80 - 13.04) and CRAE (WMD, 7.05; 95% CI, 6.65 - 7.46) than former smokers. Subgroup analysis and sensitivity analysis were performed. CONCLUSION: Firsthand tobacco smoking resulted in wider CRAE and CRVE in current and former smokers, particularly in CRVE, and such changes may not be reversible after smoking cessation. Therefore, retinal vessel caliber may reflect the effects of firsthand tobacco smoking and be used to estimate the risk of cardiovascular diseases.

12.
Brain Circ ; 9(3): 129-134, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38020952

RESUMO

The retina, as an external extension of the diencephalon, can be directly, noninvasively observed by ocular fundus photography. Therefore, it offers a convenient and feasible mode to study nervous system diseases. Caliber, tortuosity, and fractal dimension, as three commonly used retinal vascular parameters, are not only the reflection of structural changes in the retinal microcirculation but also capture the branching pattern or density changes of the retinal microvascular network. Therefore, it contributes to better reflecting the subclinical pathological changes (e.g., lacunar stroke and small cerebral vascular disease) and predicting the risk of incident stroke and recurrent stroke.

13.
Brain Circ ; 9(3): 121-128, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38020955

RESUMO

The retina is often used to evaluate the vascular health status of eyes and the whole body directly and noninvasively in vivo. Retinal vascular parameters included caliber, tortuosity and fractal dimension. These variables represent the density or geometric characteristics of the vascular network apart from reflecting structural changes in the retinal vessel system. Currently, these parameters are often used as indicators of retinal disease, cardiovascular and cerebrovascular disease. Advanced digital fundus photography apparatus and computer-assisted analysis techniques combined with artificial intelligence, make the quantitative calculation of these parameters easier, objective, and labor-saving.

14.
Front Cardiovasc Med ; 10: 1226136, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37808887

RESUMO

Background: Autogenous arteriovenous fistula (AVF) is an efficient hemodialysis access for patients with end-stage kidney disease (ESKD). The specific threshold of vein diameter still not reached a consensus. Method: We conducted a comprehensive search in PubMed, Embase, and Web of Science databases for articles which comparing the treatment outcomes of AVF with 2 mm as vein diameter threshold. Fixed and random effect model were used for synthesis of results. Subgroup analysis was designed to assess the risk of bias. Result: Eight high-quality articles were included finally. Among a total of 1,075 patients (675 males and 400 females), 227 and 809 patients possessed <2 mm and ≥2 mm vein respectively. Apart from gender and coronary artery disease (P < 0.05), there was no significant difference in age, diabetes, hypertension or radial artery between maturation and non-maturation groups. The functional maturation rate was lower in patients with <2 mm vein according to fixed effect model [OR = 0.19, 95% CI (0.12, 0.30), P < 0.01]. There was no significant difference in primary [OR = 0.63, 95% CI (0.12, 3.25), P = 0.58] or cumulative patency rates [OR = 0.40, 95% CI (0.13, 1.19), P = 0.10]. Conclusion: Vein diameter less than 2 mm has a negative impact on the functional maturation rate of AVF, while it does not affect the primary and cumulative patency rates (12 months).

15.
Plants (Basel) ; 12(15)2023 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-37570991

RESUMO

Plants of inbred maize lines are characterized by low vigor due to their high rates of homozygosity and may, therefore, benefit from additional nutrients and biostimulants supplied via foliar spraying. The present study innovatively investigated the effects of foliar treatment with three commercial organic-mineral fertilizers/biostimulants on a male-sterile inbred line of maize at the five-leaf stage. The three fertilizers were characterized by their following content: (i) NPK + hydrolyzed animal epithelium + micronutrients (named 'NPK + Hae + micro'), (ii) NK + humified peat (named 'NK + Hp'), and (iii) PK + Ascophyllum nodosum extracts (named 'PK + An'). The resulting shoot and root growth and seed yield and quality were compared to a control (C). Both NPK + Hae + micro and PK + An treatments enhanced root growth in the top 20 cm soil layer at the ten-leaf stage: root dry biomass increased by 80 and 24%, respectively, and the volumetric root length density by 61 and 17%. The two treatments also allowed for a larger number of commercial seeds to be produced (on average +16 bags per gross hectare vs. C) owing to a better seed caliber, which consequently reduced rates of seed disposal (-11 and -20% for PK + An and NPK + Hae + micro, respectively) and, in the case of NPK + Hae + micro, due to an increment in the number of kernels per ear (+5% vs. C). These effects were not associated with any significant changes in shoot growth, height, or leaf net CO2 assimilation. In this preliminary trial, peak commercial benefit was obtained with the use of hydrolyzed epithelium together with macro- and micronutrients. Further investigation into application timing and dose, and the means by which these products alleviate the effects of low vigor and stress conditions observed particularly under mechanical emasculation is, however, necessary for their full exploitation in the production of hybrid maize seeds.

16.
Micromachines (Basel) ; 14(7)2023 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-37512687

RESUMO

With the aim of achieving the combat technical requirements of super-quick (SQ) initiation and reliable self-destruction (SD) of a small-caliber projectile fuze, this paper describes a high-functional-density integrated (HFDI) inertial switch based on the "ON-OFF" state transition (i.e., almost no terminal ballistic motion). The reliable state switching of the HFDI inertial switch is studied via elastic-plastic mechanics and verified via both simulations and experiments. The theoretical and simulation results indicate that the designed switch can achieve the "OFF-ON" state transition in the internal ballistic system, and the switch can achieve the "ON-OFF" state transition in the simulated terminal ballistic system within 8 µs or complete the "ON-OFF" state transition as the rotary speed sharply decreases. The experimental results based on the anti-target method show the switch achieves the "ON-OFF" state transition on the µs scale, which is consistent with the simulation results. Compared with the switches currently used in small-caliber projectile fuzes, the HFDI inertial switch integrates more functions and reduces the height by about 44%.

17.
Vision (Basel) ; 7(3)2023 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-37489327

RESUMO

BACKGROUND: To investigate the repeatability in vessel caliber measurements by optical coherence tomography angiography (OCTA). METHODS: In this prospective study, 28 patients (47 eyes) underwent sequential OCTA imaging of the optic nerve head and macula. Two independent masked graders measured vessel caliber for sequential images of the optic nerve head and macula. The average vessel width was determined and variability between graders and images. RESULTS: A total of 8400 measurements of 420 vessels from 84 OCTA images were included in the analysis. Overall, inter-grader agreement was excellent (ICC 0.90). The coefficient of variation (CoV) for all repeated OCTA images was 0.10. Greater glaucoma severity, older age, macular location, and diagnosis of diabetes were associated with thinner vessels (p < 0.05). CoV was higher in the peripapillary region (0.07) as compared to the macula (0.15). ICC was high for all subgroups except for the macula (ICC = 0.72). CONCLUSIONS: Overall, the repeatability of vessel caliber measurements by OCTA was high and variability low. There was greater variability in the measurement of macular vessels, possibly due to technical limitations in acquiring accurate vessel widths for smaller macular vessels.

18.
Acta Diabetol ; 60(9): 1267-1277, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37277658

RESUMO

AIM: Retinal vascular parameters are biomarkers of diabetic microangiopathy. We aimed to investigate the relationship between time in range (TIR) assessed by continuous glucose monitoring (CGM) and retinal vascular parameters in patients with type 2 diabetes in China. METHODS: The TIR assessed by CGM and retinal photographs were obtained at the same time from adults with type 2 diabetes who were recruited. Retinal vascular parameters were extracted from retinal photographs by a validated fully automated computer program, and TIR was defined as between 3.9-7.8 mmol/L over a 24-h period. The association between TIR and caliber of retinal vessels distributed in different zones were analyzed using multivariable linear regression analyses. RESULTS: For retinal vascular parameters measurements, the peripheral arteriovenous and middle venular calibers widen with decreasing TIR quartiles (P < 0.05). Lower TIR was associated with wider peripheral venule after adjusting for potential confounders. Even after further correction for GV, there was still a significant correlation between TIR and peripheral vascular calibers (CV: ß = - 0.015 [- 0.027, - 0.003], P = 0.013; MAGE: ß = - 0.013 [- 0.025, - 0.001], P = 0.038) and SD: ß = - 0.013 [- 0.026, - 0.001], P = 0.004). Similar findings were not found for the middle and central venular calibers or arterial calibers located in different zones. CONCLUSIONS: The TIR was associated with adverse changes to peripheral retinal venules but not central and middle vessels in patients with type 2 diabetes, suggesting that peripheral retinal vascular calibers may be affected by glycemic fluctuations earlier.


Assuntos
Diabetes Mellitus Tipo 2 , Adulto , Humanos , Diabetes Mellitus Tipo 2/complicações , Vênulas , Automonitorização da Glicemia , Glicemia , Vasos Retinianos
19.
J Plast Reconstr Aesthet Surg ; 83: 94-97, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37271002

RESUMO

INTRODUCTION: The microsurgical literature reports the vascular calibers of the vessels studied even though the method of measurement of these vessels is very rarely reported. MATERIAL AND METHOD: We performed a metrological study evaluating three methods to measure the external calibers of catheters corresponding to microsurgical and super-microsurgical vessels (1.2 mm, 0.8 mm, and 0.6 mm). Six evaluators measured 15 catheters of three different hidden diameters by each of the three methods applicable in clinical practice: standard graduated ruler, Shinwa® micrometric ruler, and ImageJ® software from a photograph. Accuracy and reliability of the measurements were assessed by studying the inter- and intra-rater and inter-method coefficients (variants of the intra-class coefficient (ICC)) and analysis of the IC95% of the ICCs. RESULTS: Intra class correlation ICC "intra-rater" coefficient finds for the standard rule 0.81 [0.65-0.93], Shinwa® rule 0.86 [0.67-0.96], and for the ImageJ® software 0.97 [0.94-0.99]. The "Inter-rater" ICC shows respectively the coefficient 0.51 [0.23 and max 0.93], 0.87 [0.75-0.95], and 0.95 [0.89-0.98]. It appears that the graduated decimeter is the least reliable method of measurement, the Shinwa® ruler presents acceptable reliability but requires the purchase of equipment. The reliability of ImageJ® software is the best and appears to be the most reliable method. CONCLUSION: Our original study, with no equivalent in the scientific literature, demonstrates objectively the great accuracy and reliability of a method of measurement of vascular calibers in micro and super microsurgery using intraoperative photography and the use of free computer software.


Assuntos
Microcirurgia , Software , Humanos , Reprodutibilidade dos Testes , Fotografação , Variações Dependentes do Observador
20.
Hemodial Int ; 27(3): 241-248, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37134023

RESUMO

INTRODUCTION: Balloon angioplasty maturation (BAM) is a salvage method for autologous arteriovenous fistula (AVF) maturation failure. AVF creation using small-diameter veins is considered to have poor outcomes. Therefore, this study aimed to explore the long-term patency of small-diameter veins (≤3 mm) using BAM. METHODS: BAM was performed if the fistula failed to mature and function adequately to provide prescribed dialysis. FINDINGS: Out of 61 AVFs, 22 AVFs successfully matured without further intervention (AVF group) and 39 AVFs failed to mature. Except for 1 patient who required peritoneal dialysis, the remaining 38 patients received salvage BAM, and 36 of those successful matured (BAM group). Kaplan-Meier analysis revealed no significant differences between the AVF and BAM groups in terms of primary functional patency (p = 0.503) and assisted functional patency (p = 0.499). Compared with the AVF group, the BAM group had similar assisted primary functional patency (1-year: 94.7% vs. 93.1%; 3-year: 88.0% vs. 93.1%; 5-year: 79.2% vs. 88.3%). In addition, there were no significant difference between groups in the duration of primary functional patency and assisted primary functional patency (p > 0.05). Multivariate analyses showed that vein diameter and number of BAM procedures were independent predictors of primary functional patency in the AVF group and BAM group, respectively. Patient with 1 mm increase in vein size had 0.13-fold probability of having decreased duration of patency (HR = 0.13, 95% CI: 0.02-0.99, p = 0.049), while patients who received two times of BAM procedures were 2.885 as likely to have decreased duration of primary functional patency (HR = 2.885, 95% CI: 1.09-7.63, p = 0.033) than patients who received one BAM procedure. DISCUSSION: BAM is a relatively effective salvage management option with an acceptable long-term patency rate, even for small cephalic veins.


Assuntos
Fístula Arteriovenosa , Derivação Arteriovenosa Cirúrgica , Humanos , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Grau de Desobstrução Vascular , Resultado do Tratamento , Diálise Renal , Fatores de Risco , Fístula Arteriovenosa/etiologia , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...