Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Rev. bras. ciênc. vet ; 26(2): 51-54, abr./jun. 2019. il.
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1392202

RESUMO

The goal of this research was to identify the frequency of the DEA 1.1 blood group in dogs from Sinop, Mato Grosso, Brazil, to help in the recruitment of compatible blood donors and recipients, and to assess the risk of transfusion reactions in previously sensitized dogs. Also, from the obtained results, to pick potential blood donors to compose a data bank. 195 adult dogs (1 to 4 years old), males and females, mongrel and purebred dogs were screened at the Veterinary Hospital of the University of Mato Grosso. The DEA 1.1 blood typing was performed using commercially available immunochromatographic strip for DEA 1.1 (Quick Test DEA 1.1, Alvedia, Lyon, France). The results showed a general frequency of 65% for DEA 1.1 positive dogs (n = 126) and 35% for DEA 1 negative dogs (n = 69). The general risk of sensitization of a DEA 1 negative dog following a first transfusion with DEA 1.1 positive blood was 23%, while the risk of this sensitized recipient to receive DEA 1.1 positive blood in a second transfusion and to develop an acute hemolytic reaction was calculated to be 5%. The blood typing of the dogs allowed their classification as DEA 1 typed blood donors, in a preliminary data bank, and also ensured the safety of blood transfusions.


Objetivou-se identificar a frequência do grupo sanguíneo DEA 1.1 em cães de Sinop, Mato Grosso, Brasil, para auxiliar a seleção de doadores e receptores de sangue compatíveis e, adicionalmente, avaliar o risco de reações transfusionais em cães sensibilizados. Além disso, a partir dos resultados obtidos, selecionar potenciais doadores de sangue para compor um banco de dados. Um total de 195 cães adultos (de 1 a 4 anos de idade), machos e fêmeas, mestiços e puros, que nunca haviam recebido transfusões de sangue, foram triados no Hospital Veterinário da Universidade do Mato Grosso. A tipagem sanguínea DEA 1.1 foi realizada utilizando-se ensaio imunocromatográfico comercialmente disponível para DEA 1.1 (Quick Test DEA 1.1, Alvedia, Lyon, França). Os resultados demonstraram uma frequência geral de 65% para cães DEA 1.1 positivos (n = 126) e 35% para cães DEA 1 negativos (n = 69). O risco geral de sensibilização de cães DEA 1 negativos após uma primeira transfusão com sangue DEA 1.1 positivo foi calculado em 23%, enquanto o risco deste receptor sensibilizado receber sangue DEA 1.1 positivo em uma segunda transfusão e desenvolver uma reação hemolítica aguda foi calculado em 5%. A tipagem sanguínea dos cães permitiu sua inserção como doadores de sangue tipados para o grupo DEA 1 em um banco de dados preliminar e garantiu a segurança das transfusões de sangue.


Assuntos
Animais , Cães , Sangue/imunologia , Doadores de Sangue , Antígenos de Grupos Sanguíneos/análise , Transfusão de Sangue/veterinária , Tipagem e Reações Cruzadas Sanguíneas/veterinária , Cães/sangue , Reação Transfusional/veterinária
2.
Rev. bras. ciênc. vet ; 26(2): 51-54, abr./jun. 2019. tab
Artigo em Português | LILACS, VETINDEX | ID: biblio-1491639

RESUMO

Objetivou-se identificar a frequência do grupo sanguíneo DEA 1.1 em cães de Sinop, Mato Grosso, Brasil, para auxiliar a seleção de doadores e receptores de sangue compatíveis e, adicionalmente, avaliar o risco de reações transfusionais em cães sensibilizados. Além disso, a partir dos resultados obtidos, selecionar potenciais doadores de sangue para compor um banco de dados. Um total de 195 cães adultos (de 1 a 4 anos de idade), machos e fêmeas, mestiços e puros, que nunca haviam recebido transfusões de sangue, foram triados no Hospital Veterinário da Universidade do Mato Grosso. A tipagem sanguínea DEA 1.1 foi realizada utilizando-se ensaio imunocromatográfico comercialmente disponível para DEA 1.1 (Quick Test DEA 1.1, Alvedia, Lyon, França). Os resultados demonstraram uma frequência geral de 65% para cães DEA 1.1 positivos (n = 126) e 35% para cães DEA 1 negativos (n = 69). O risco geral de sensibilização de cães DEA 1 negativos após uma primeira transfusão com sangue DEA 1.1 positivo foi calculado em 23%, enquanto o risco deste receptor sensibilizado receber sangue DEA 1.1 positivo em uma segunda transfusão e desenvolver uma reação hemolítica aguda foi calculado em 5%. A tipagem sanguínea dos cães permitiu sua inserção como doadores de sangue tipados para o grupo DEA 1 em um banco de dados preliminar e garantiu a segurança das transfusões de sangue.


The goal of this research was to identify the frequency of the DEA 1.1 blood group in dogs from Sinop, Mato Grosso, Brazil, to help in the recruitment of compatible blood donors and recipients, and to assess the risk of transfusion reactions in previously sensitized dogs. Also, from the obtained results, to pick potential blood donors to compose a data bank. 195 adult dogs (1 to 4 years old), males and females, mongrel and purebred dogs were screened at the Veterinary Hospital of the University of Mato Grosso. The DEA 1.1 blood typing was performed using commercially available immunochromatographic strip for DEA 1.1 (Quick Test DEA 1.1, Alvedia, Lyon, France). The results showed a general frequency of 65% for DEA 1.1 positive dogs (n = 126) and 35% for DEA 1 negative dogs (n = 69). The general risk of sensitization of a DEA 1 negative dog following a first transfusion with DEA 1.1 positive blood was 23%, while the risk of this sensitized recipient to receive DEA 1.1 positive blood in a second transfusion and to develop an acute hemolytic reaction was calculated to be 5%. The blood typing of the dogs allowed their classification as DEA 1 typed blood donors, in a preliminary data bank, and also ensured the safety of blood transfusions.


Assuntos
Animais , Cães , Antígenos de Grupos Sanguíneos/análise , Cães/sangue , Reação Transfusional/veterinária
3.
Braz. j. vet. res. anim. sci ; 51(4): 316-323, 2014.
Artigo em Português | LILACS | ID: lil-750884

RESUMO

O presente trabalho estudou a frequência dos grupos sanguíneos identificados como antígenos eritrocitários caninos (AEC) 1, 1.1 e 7 em cães da região metropolitana da cidade de São Paulo-SP, Brasil, e calculou o risco de administração de sangue incompatível tanto em uma primeira quanto em uma segunda transfusão. Para tanto, 300 cães não aparentados foram divididos igualmente em seis grupos de acordo com as raças: Pastor Alemão (PA); Rottweiler (R); Poodle (P); Cocker Spaniel Inglês (CS); raças definidas diversas (RDD) e mestiços (M). Foi avaliada a relação entre a frequência dos AEC e os grupos raciais. A frequência geral de AEC 1 na população foi de 71 por cento (AEC 1.1 – 53,35 por cento) e houve variações de acordo com as raças: PA- 32 por cento (AEC 1.1 – 20 por cento), R- 98 por cento (1.1 – 80 por cento), P- 76 por cento (1.1 – 54 por cento), CS- 84 por cento (1.1 – 50 por cento), RDD- 62 por cento (1.1 – 56 por cento) e M- 74 por cento (1.1 – 60 por cento). A frequência geral de AEC 7 foi de 39,33 por centoe não houve diferenças significativas entre as raças. O risco de um cão negativo para o AEC 1 receber sangue positivo foi de 0,6 a 66,6 por cento em uma primeira transfusão e de 0,21 a 65,3 por cento do mesmo cão receber sangue incompatível em uma segunda transfusão. O risco quanto ao AEC 7 foi de 23,86 por cento na primeira transfusão e 9,4 por cento numa segunda transfusão. Este trabalho concluiu que houve variação na frequência de AEC1 e AEC 1.1, mas não quanto ao AEC 7 entre raças. Esta variação na porcentagem de animais positivos quanto ao AEC 1 se refletiu na grande variação no risco de uso de sangue incompatível. Portanto, conhecer a frequência dos AEC na população tem impacto direto no manejo entre cães doadores e receptores, mas a utilização conjunta de teste de tipagem sanguínea e reação cruzada reduz a possibilidade de transfusão de sangue incompatível.


It was investigated the frequency of blood groups identified as Dog Erythrocyte Antigens (DEA) 1, 1.1 and 7 dogs in the metropolitan region of São Paulo-SP, Brazil, and calculated the risk of administering incompatible blood in both first and second transfusion. For both, 300 unrelated dogs were equally divided into six groups according to the breeds: German Shepherd (GS), Rottweiler (R) Poodle (P), Cocker Spaniel (CS); defined several races (DSR), mongrel dogs (M). It was evaluated the relationship between the frequency of AEC and racial groups. The overall frequency of DEA 1 in population was 71 percent (DEA 1.1 – 53.35 percent) and there were variations according to the breeds: GS- 32 percent (DEA 1.1 – 20 percent), R –98 percent (1.1 – 80 percent) P – 76 percent (1.1 – 54 percent), CS-84 percent (1.1 – 50 percent), DSR- 62 percent (1.1 – 56 percent) and M – 74 percent(1.1 – 60 percent). The overall frequency of BCE 7 was 39.33 percent, and there were no significant differences between the breeds. The risk of a dog negative DEA receiving 1 positive blood was 0.6 to 66.6 percent in the first transfusion and 0.21 to 65.3 percent from the same animal dog receiving incompatible blood transfusion in a second. The risk of the DEA 7 was 23.86 percent in the first transfusion and 9.4 percent in a second transfusion. This study concluded that there was variation in the frequency of DEA 1 and 1.1, but not on the DEA 7 between races. This variation in the percentage of positive animals to DEA 1 was reflected in the large variation in the risk of use of incompatible blood. Therefore, knowing the frequency of the DEA in the population has a direct impact on handling dogs between donors and recipients, but the joint use of testing blood typing and cross-reactivity reduces the possibility of incompatible blood transfusion.


Assuntos
Animais , Cães/classificação , Policitemia , Transfusão de Sangue/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...