Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Turk J Med Sci ; 49(4): 1170-1178, 2019 08 08.
Artigo em Inglês | MEDLINE | ID: mdl-31340632

RESUMO

Background/aim: To compare the inferior vena cava (IVC) indices, identify their variation rates at positive pressure values and accurate predictive values for the volume status in patients with spontaneous respiration receiving different positive pressure support. Materials and methods: The study included 100 patients who were divided into 4 pressure support groups, according to the different pressure supports received, and 3 volume groups according to their CVP values. Ultrasonography was applied to all of the patients to define their IVC diameters at different pressure supports. Dynamic parameters were derived from the ultrasonographic assessment of the IVC diameter [collapsibility (CI-IVC), distensibility (dIVC), and delta (ΔIVC) indices]. Results: There were significant differences between the 3 indices (CI-IVC, dIVC, and ΔIVC) according to the pressure groups [(10/5), (10/0), (0/5), (t tube 0/0)]. The median value for the dIVC percentages was ≤18% for all of the positive pressure support hypervolemic groups, apart from the hypervolemic t tube group (19%). For the hypervolemic groups, the best estimation according to the cut-off value appeared to be for the dIVC. Values with the highest sensitivity for differentiation of the hypovolemic individuals were calculated with the dIVC. Conclusion: The dIVC had a more accurate predictive role in predicting the volume status when compared with the CI-IVC and ΔIVC, and may be used reliably with positive pressure supports.


Assuntos
Volume Sanguíneo/fisiologia , Respiração com Pressão Positiva , Veia Cava Inferior , Idoso , Pressão Venosa Central/fisiologia , Cuidados Críticos , Feminino , Humanos , Hipovolemia/diagnóstico por imagem , Hipovolemia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Ultrassonografia , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/fisiopatologia
2.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-610385

RESUMO

Objective To explore the value of transesophageal doppler in transurethral resection prostate.Methods Thirty-six patients (aged 60-85 years, falling into ASA grade Ⅰ-Ⅲ) of benign prostatic hyperplasia for undergoing transurethral resection prostate were enrolled.Through multifunction monitor, CVP, Narcotrend index(NI) were monitored before anesthesia induction (T0), 20 minutes after anesthesia induction (T1), after irrigating fluid of 5 000 ml (T2) and 10 000 ml (T3) and 15 000 ml (T4) and 20 000 ml (T5).By transesophageal doppler, FTc(corrected flowtime), SV(stroke volume), ΔPV(peak flow vaviable quantity) were monitored at T1-T5.Results CVP at T1-T5 were not significantly changed compared with that at T0.Compared with T1, FTc, SV at T3-T5were significantly increased and ΔPV at T2-T5were significantly decreased (P<0.05).CVP levels correlated significantly with both FTc (r=0.702, P<0.01) and SV (r=0.595, P<0.01).CVP negatively correlated significantly with ΔPV (r=-0.351, P<0.05).Furthermore, FTc correlated significantly with the concentrationof Na+(r=0.672,P<0.01).No patient had serum sodium ion concentration less than 125 mmol/L.Conclusion FTc of transesophageal doppler is as accurate as central venous pressure in monitoring hemodynamic changes, and even more sensitive than CVP.It is useful in early diagnosis and treatment of TURS.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...