Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 83
Filtrar
1.
World J Gastrointest Surg ; 16(6): 1527-1536, 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38983348

RESUMO

BACKGROUND: Natural orifice specimen extraction surgery (NOSES) has emerged as a promising alternative compared to conventional laparoscopic-assisted total gastrectomy (LATG) for treating gastric cancer (GC). However, evidence regarding the efficacy and safety of NOSES for GC surgery is limited. This study aimed to compare the safety and feasibility, in addition to postoperative complications of NOSES and LATG. AIM: To discuss the postoperative effects of two different surgical methods in patients with GC. METHODS: Dual circular staplers were used in Roux-en-Y digestive tract reconstruction for transvaginal specimen extraction LATG, and its outcomes were compared with LATG in a cohort of 51 GC patients with tumor size ≤ 5 cm. The study was conducted from May 2018 to September 2020, and patients were categorized into the NOSES group (n = 22) and LATG group (n = 29). Perioperative parameters were compared and analyzed, including patient and tumor characteristics, postoperative outcomes, and anastomosis-related complications, postoperative hospital stay, the length of abdominal incision, difference in tumor type, postoperative complications, and postoperative survival. RESULTS: Postoperative exhaust time, operation duration, mean postoperative hospital stay, length of abdominal incision, number of specific staplers used, and Brief Illness Perception Questionnaire score were significant in both groups (P < 0.01). In the NOSES group, the postoperative time to first flatus, mean postoperative hospital stay, and length of abdominal incision were significantly shorter than those in the LATG group. Patients in the NOSES group had faster postoperative recovery, and achieved abdominal minimally invasive incision that met aesthetic requirements. There were no significant differences in gender, age, tumor type, postoperative complications, and postoperative survival between the two groups. CONCLUSION: The application of dual circular staplers in Roux-en-Y digestive tract reconstruction combined with NOSES gastrectomy is safe and convenient. This approach offers better short-term outcomes compared to LATG, while long-term survival rates are comparable to those of conventional laparoscopic surgery.

2.
Tech Coloproctol ; 28(1): 76, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38954099

RESUMO

BACKGROUND: Colorectal anastomotic leakage causes severe consequences for patients and healthcare system as it will lead to increased consumption of hospital resources and costs. Technological improvements in anastomotic devices could reduce the incidence of leakage and its economic impact. The aim of the present study was to assess if the use of a new powered circular stapler is cost-effective. METHOD: This observational study included patients undergoing left-sided circular stapled colorectal anastomosis between January 2018 and December 2021. Propensity score matching was carried out to create two comparable groups depending on whether the anastomosis was performed using a manual or powered circular device. The rate of anastomotic leakage, its severity, the consumption of hospital resources, and its cost were the main outcome measures. A cost-effectiveness analysis comparing the powered circular stapler versus manual circular staplers was performed. RESULTS: A total of 330 patients were included in the study, 165 in each group. Anastomotic leakage rates were significantly different (p = 0.012): 22 patients (13.3%) in the manual group versus 8 patients (4.8%) in the powered group. The effectiveness of the powered stapler and manual stapler was 98.27% and 93.69%, respectively. The average cost per patient in the powered group was €6238.38, compared with €9700.12 in the manual group. The incremental cost-effectiveness ratio was - €74,915.28 per patient without anastomotic complications. CONCLUSION: The incremental cost of powered circular stapler compared with manual devices was offset by the savings from lowered incidence and cost of management of anastomotic leaks.


Assuntos
Anastomose Cirúrgica , Fístula Anastomótica , Colo , Análise Custo-Benefício , Reto , Grampeadores Cirúrgicos , Grampeamento Cirúrgico , Humanos , Fístula Anastomótica/prevenção & controle , Fístula Anastomótica/economia , Fístula Anastomótica/etiologia , Feminino , Grampeadores Cirúrgicos/economia , Masculino , Anastomose Cirúrgica/efeitos adversos , Anastomose Cirúrgica/economia , Anastomose Cirúrgica/instrumentação , Anastomose Cirúrgica/métodos , Pessoa de Meia-Idade , Idoso , Incidência , Grampeamento Cirúrgico/economia , Grampeamento Cirúrgico/métodos , Grampeamento Cirúrgico/efeitos adversos , Grampeamento Cirúrgico/instrumentação , Colo/cirurgia , Reto/cirurgia , Pontuação de Propensão , Adulto , Análise de Custo-Efetividade
3.
Cancer Diagn Progn ; 4(4): 510-514, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38962541

RESUMO

Background/Aim: The present study examined the impact of circular stapler size on anastomotic complications, including leakage and stricture in patients undergoing double-stapling technique (DST) anastomosis for left-sided colon or rectal cancer. Patients and Methods: A total of 403 patients were enrolled in this study, with circular stapler sizes  of 25, 28, and 29 mm. Results: A small circular stapler (25 mm) was used in 170 cases (42.2%), and a medium-sized circular stapler (28/29 mm) was used in 233 cases (57.8%). After propensity score matching, there was no marked difference in the incidence of anastomotic leakage/stricture between the groups (13.9% vs. 10.9%, 3.0% vs. 1.0%, respectively). Conclusion: The size of the circular stapler was not associated with the incidence of anastomotic leakage or stricture in this cohort.

4.
Int J Colorectal Dis ; 39(1): 51, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38607585

RESUMO

PURPOSE: Three types of circular staplers can be used to perform a colorectal anastomosis: two-row (MCS), three-row (TRCS) and powered (PCS) devices. The objective of this meta-analysis has been to provide the existing evidence on which of these circular staplers would have a lower risk of presenting a leak (AL) and/or anastomotic bleeding (AB). METHODS: An in-depth search was carried out in the electronic bibliographic databases Embase, PubMed and SCOPUS. Observational studies were included, since randomized clinical trials comparing circular staplers were not found. RESULTS: In the case of AL, seven studies met the inclusion criteria in the PCS group and four in the TRCS group. In the case of AB, only four studies could be included in the analysis in the PCS group. The AL OR reported for PCS was 0.402 (95%-confidence interval (95%-CI): 0.266-0.608) and for AB: 0.2 (95% CI: 0.08-0.52). The OR obtained for AL in TRCS was 0.446 (95%-CI: 0.217 to 0.916). Risk difference for AL in PCS was - 0.06 (95% CI: - 0.07 to - 0.04) and in TRCS was - 0.04 (95%-CI: - 0.08 to - 0.01). Subgroup analysis did not report significant differences between groups. On the other hand, the AB OR obtained for PCS was 0.2 (95% CI: 0.08-0.52). In this case, no significant differences were observed in subgroup analysis. CONCLUSION: PCS presented a significantly lower risk of leakage and anastomotic bleeding while TRCS only demonstrated a risk reduction in AL. Risk difference of AL was superior in the PCS than in TRCS.


Assuntos
Neoplasias Colorretais , Grampeadores Cirúrgicos , Humanos , Anastomose Cirúrgica/métodos
5.
Updates Surg ; 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38451410

RESUMO

OBJECTIVE: This study evaluates feasibility, safety, and short-term outcomes of employing the catheter-guided stapler anvil insertion technique for esophagojejunal anastomosis using a circular stapler during laparoscopic total gastrectomy (LTG). MATERIALS AND METHODS: From September 2021 to April 2023, the catheter-guided stapler anvil insertion technique was employed in 80 patients undergoing laparoscopic total gastrectomy (LTG) for esophagojejunal anastomosis. A modified D2 dissection, according to the en bloc technique, was performed in the patients. Subsequently, a longitudinal incision, approximately 2 cm in length, was made on the anterior wall of the esophagus, about 2 cm above the tumor. The transection line was pre-marked with blue dye along the esophagus's minor axis, and the tail of the anvil was capped with a 10-cm length of catheter (F14 d4.7 mm). The surgeon secures the head of anvil and carefully inserts it into the esophagus, ensuring that only a 5-cm segment of the catheter remains outside the esophagus. A linear cutter was employed to transect and seal the lower end of the esophagus. Subsequently, esophagojejunostomy was performed under laparoscopic guidance using a circular stapler. RESULTS: Among patients undergoing esophagojejunal anastomosis with the new technique, postoperative complications included pneumonia or pleural effusion in 14 patients (17.5%), anastomotic stenosis in 3 patients (3.75%), abdominal infection in 2 patients (2.5%), and intestinal obstruction in 1 patient (1.25%). No instances of anastomotic leakage, anastomotic bleeding, or deaths were recorded. All patients experiencing complications improved with conservative treatment, without the need for secondary surgery. CONCLUSION: The catheter-guided stapler anvil insertion technique is demonstrated to be a safe and effective method for esophagojejunostomy, potentially reducing the occurrence of anastomotic leakage.

6.
BMC Surg ; 23(1): 332, 2023 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-37898761

RESUMO

BACKGROUND: The most common postoperative complication in malignant rectal surgery is anastomotic leakage (AL). AL after anterior or low anterior resection in rectal tumors is a fatal postoperative complication. Recently, the first automated suture circular stapler, which is expected to reduce the incidence of AL, (J&J). MATERIALS AND METHODS: This study included a total of 248 rectal tumor patients who underwent double stapler technique (DST) anastomotic procedures in the department of gastroenterological surgery /pediatric surgery at Gifu University School of Medicine from January 2017 to December 2021. The experience of a single institution utilizing the The Echelon circular™ stapler (ECP stapler:Manual VS Automatic) in rectal surgery cases was evaluated retrospectively from maintained database. RESULT: One hundred thirty-nine patients (58.4%) were performed by manual circular stapling, 99 patients (41.6%) by powerd circular stapling. Diverting stoma was performed in 45 cases (32.4%) by manual circular stapling, 42 patients (42.4%) by powerd circular stapling Postoperative complications were occurred clavien-dindo grade II or higher in 57 cases (23.9%) and grade III or higher in 20 cases (8.4%). Anastomotic leakage occurred in 14 patients (5.9%) within all grades. After IPTW, the variables of patient characteristics was SMD ≤ 0.2 (Table.3), and there was a significant difference in anastomotic leakage (Odds Ratio (OR), 0.57; 95% Confidence Interval(CI), 0.34-0.98; p = 0.041). In addition, there was no significant difference in postoperative complications in grade II or higher (OR, 0.88; 95%CI, 0.65-1.19; p = 0.417) and grade III or higher (OR, 0.46; 95%CI, 0.29-0.74; p = 0.001) were significantly remarkable lower in powered circular stapling group. CONCLUSION: In this IPTW comparison of patients undergoing rectal reconstructions, the ECP trial cohort had lower risks of several surgical complications AL and statistically signifcant lower rates of ileus/bowel obstruction, infection, and bleeding as Clavien-Dindo ≥ grade II and III as compared with for whom manual circular staplers were used.


Assuntos
Laparoscopia , Neoplasias Retais , Criança , Humanos , Fístula Anastomótica/etiologia , Estudos Retrospectivos , Grampeamento Cirúrgico/métodos , Neoplasias Retais/cirurgia , Neoplasias Retais/complicações , Anastomose Cirúrgica/métodos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/cirurgia , Fatores de Risco , Laparoscopia/métodos
8.
Int J Colorectal Dis ; 38(1): 211, 2023 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-37561203

RESUMO

PURPOSE: The aim of the present study is to assess the impact of Echelon Circular™ powered stapler (PCS) on left-sided colorectal anastomotic leaks and to compare results to conventional circular staplers (CCS). METHODS: A single center cohort study was carried out on 552 consecutive patients, who underwent laparoscopic colorectal resection and anastomosis to the rectum between December 2017 and September 2022. Patients who underwent powered circular anastomosis to the rectum were matched to those who had a conventional stapled anastomosis using a propensity score matching. Main outcomes were anastomotic leak (AL) rate, anastomotic bleeding, and postoperative outcomes. RESULTS: After adjusting cases with propensity score matching, two new groups of patients were generated: 145 patients in the PCS and 145 in the CCS. The two groups were homogeneous with respect to demographics and comorbidities on admission. Overall, AL occurred in 21 (7.3%) patients. No significant differences were observed with respect to AL (5.5% in PCS vs 9% in CCS; p = 0.66), fistula severity (p = 0.60) or reoperation rate (p = 0.65) in the two groups in study. A higher rate of anastomotic bleeding was observed in the CCS vs PCS (5.5% vs 0.7%, p = 0.03). At univariate analysis performed after propensity score matching, stapler diameter ≥ 31mm and age ≥ 70 years were the only variable significantly associated with anastomotic leak (p = 0.001 and p = 0.031; respectively). CONCLUSIONS: The powered circular stapler has no impact on AL, while it could affect bleeding rate at the anastomotic site.


Assuntos
Fístula Anastomótica , Neoplasias Colorretais , Humanos , Idoso , Fístula Anastomótica/etiologia , Fístula Anastomótica/cirurgia , Reto/cirurgia , Estudos de Coortes , Pontuação de Propensão , Grampeadores Cirúrgicos/efeitos adversos , Anastomose Cirúrgica/efeitos adversos , Anastomose Cirúrgica/métodos , Estudos Retrospectivos , Neoplasias Colorretais/cirurgia , Grampeamento Cirúrgico/efeitos adversos , Grampeamento Cirúrgico/métodos
9.
BMC Surg ; 23(1): 205, 2023 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-37464350

RESUMO

BACKGROUND: The powered circular stapler, which was developed with the aim of providing reliable and reproducible anastomosis, provides complete anastomosis, resulting in a reduced risk of anastomotic leakage. The aim of this study was to compare the incidence of anastomotic leakage between a conventional manual circular stapler (MCS) and the ECHELON CIRCULAR™ Powered Stapler (ECPS) in patients with left-sided colorectal cancer who underwent anastomosis with the double stapling technique. METHODS: A total of 187 patients with left-sided colorectal cancer who underwent anastomosis with the double stapling technique with a conventional MCS or the ECPS during surgery at Osaka City University Hospital between January 2016 and July 2022 were enrolled in this study. RESULTS: The incidence of anastomotic leakage in the ECPS group was significantly lower than that in the MCS group (4.4% versus 14.3%, p = 0.048). Furthermore, even after propensity score matching, an association was found between the use of the ECPS and a reduced incidence of anastomotic leakage. CONCLUSION: The ECPS has the potential to help reduce the rate of anastomotic leakage in left-sided colorectal surgery.


Assuntos
Fístula Anastomótica , Neoplasias Colorretais , Humanos , Fístula Anastomótica/epidemiologia , Fístula Anastomótica/etiologia , Fístula Anastomótica/prevenção & controle , Estudos Retrospectivos , Grampeamento Cirúrgico/métodos , Anastomose Cirúrgica/métodos , Neoplasias Colorretais/cirurgia , Neoplasias Colorretais/complicações
10.
J Minim Invasive Surg ; 26(2): 64-71, 2023 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-37347097

RESUMO

Purpose: In minimally invasive esophagectomy (MIE), it is important to reduce the rate of anastomotic leakage to ensure its safety. At our institute, the double-ligation method (DLM) has been introduced to insert and fix the anvil of the circular stapler for intracorporeal circular esophagojejunostomy in gastric surgery. We adopted this method for intrathoracic anastomosis (IA) in MIE. The aim of this study was to investigate the safety of IA with DLM in MIE. Methods: In this study, 48 patients diagnosed with primary middle or lower third segment thoracic esophageal carcinoma with clinical stage I, II, III or IV disease were retrospectively evaluated. Postoperative outcomes were assessed. Results: Among the 48 patients, 42 patients underwent laparo-thoracoscopic esophagectomy and IA using a circular stapler with the DLM. The average total operation time and thoracoscopic operation time were 433 and 229 minutes, respectively. The average purse-string suturing time was 4.7 minutes. The rates of anastomotic leakage and stenosis were 2.4% and 14.3%, respectively. The overall incidence of postoperative complications (Clavien-Dindo grade of ≥III) was 16.7%. The average postoperative stay was 16 days. Conclusion: The procedure of IA using a circular stapler with the DLM in MIE was safe and provided a low rate of anastomotic leakage.

11.
J Anus Rectum Colon ; 7(2): 82-90, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37113589

RESUMO

Objectives: Preventing anastomotic complications during rectal cancer surgery is important. Compared with a manual circular stapler, a powered circular stapler is expected to reduce undesirable tension during anastomosis. However, whether a powered circular stapler can reduce anastomotic complications during robotic low anterior resection (Ro-LAR) remains unclear. We aimed to investigate whether the use of a powered circular stapler contributes to safe anastomosis in Ro-LAR. Methods: A total of 271 patients who underwent Ro-LAR for rectal cancer between April 2019 and April 2022 were included. Depending on the type of device employed, patients were divided into a powered circular stapler group (PCSG) and a manual circular stapler group (MCSG). Clinicopathological features and surgical outcomes were compared between the two groups. Results: There were no differences in clinicopathological characteristics and surgical outcomes, except for anastomotic outcomes, between the two groups. Patients with positive air leak tests were significantly more in the MCSG (p=0.026; PCSG, 1.5%; MCSG, 8.0%). Frequencies of anastomotic leakage (p=0.486; PCSG, 6.1%; MCSG, 8.9%) and anastomotic bleeding (p=1.000; PCSG, 0.7%; MCSG, 0.8%) were similar between the two groups. Multivariate analysis showed that the use of a powered circular stapler significantly increased the negative leak tests (p=0.020, odds ratio 6.74, 95% confidence interval 1.35-33.56). Conclusions: Use of a powered circular stapler in Ro-LAR for rectal cancer was significantly associated with a negative air leak test, suggesting that it contributes to stable and safe anastomosis.

12.
Surg Innov ; 30(5): 576-585, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37029908

RESUMO

BACKGROUND: Circular stapler anastomosis is a common surgical procedure. Despite technological advancements, anastomotic leak remains a postoperative concern. Assessment of new technologies is impeded by variations in test methods and analysis, precluding outcome reproducibility and direct comparisons of results across studies. The development of robust and reproducible preclinical test methods is critical to accelerating stapling technology advancements. METHODOLOGY: Leak pressure, staple line perfusion and security, and device removal force were quantified for triple-row (Tri-staple EEA, TriEEA) and double-row staplers (Echelon Circular Powered, ECP). Leak and perfusion testing were performed in vivo. Device removal force and staple line security testing were performed with synthetic medium using an Instron. Data were analyzed using unpaired student's t-test or Kruskal-Wallis test, with statistical significance defined as P < .05. RESULTS: Leak pressure was 73% higher in TriEEA vs ECP (P = .016). TriEEA staple line failure force was lower than ECP at 40 and 50 mmHg (P = .001 and P = .023, respectively). Perfusion to the staple line was higher (148%) for TriEEA than for ECP (P = .003) and the force required to remove the device from its stapled anastomosis was 78% lower for TriEEA than for ECP (P < .001). DISCUSSION/CONCLUSIONS: This report addresses a primary limitation in stapling research by presenting novel methodologies which enhance clinical relevance and provide sufficient detail for reproduction by independent investigators. These methods are applied to a comparison between triple-row and double-row staplers to demonstrate utility of new test methods in assessing key technology design features.


Assuntos
Grampeadores Cirúrgicos , Grampeamento Cirúrgico , Humanos , Grampeamento Cirúrgico/métodos , Reprodutibilidade dos Testes , Fístula Anastomótica/prevenção & controle , Anastomose Cirúrgica/métodos
13.
Langenbecks Arch Surg ; 408(1): 7, 2023 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-36597004

RESUMO

PURPOSE: The use of a small circular stapler has been reported to increase the incidence of benign anastomotic stenosis in reconstruction. In circular stapling anastomosis after esophagectomy, the anastomotic lumen is dependent on the size of the esophagus and the replacement organ. We developed a new and foolproof method to prevent stenosis in esophagogastric tube anastomosis for patients with esophageal cancer that is not dependent on operator skill. METHODS: Seven patients with esophageal squamous cell carcinoma underwent minimally invasive McKeown esophagectomy in our hospital. Esophagogastric tube anastomosis was tried for all patients using the novel "hybrid esophagogastric tube anastomosis" technique. A 21-mm circular stapler was applied to perform an end-to-side anastomosis between the cervical esophagus and the posterior wall of the gastric tube. Then, a 30-mm linear stapler was positioned in the esophagogastric anastomosis formed by the 21-mm circular stapler with the anvil fork inserted into the esophagus and the cartridge fork inserted into the gastric tube. A supplementary side-to-side anastomosis of appropriately 15 mm was created. Afterward, the entry hole was closed with a linear stapler. RESULTS: The hybrid esophagogastric tube anastomosis was successful in all seven patients receiving it between June 2020 and March 2022. No postoperative complications related to this anastomosis were observed in any of the patients. Five patients underwent follow-up gastrointestinal endoscopy at 6 months after esophagectomy. No patient had an anastomotic stenosis. CONCLUSIONS: Hybrid esophagogastric tube anastomosis can be performed easily and safely and can reduce the complications associated with anastomosis.


Assuntos
Neoplasias Esofágicas , Carcinoma de Células Escamosas do Esôfago , Humanos , Neoplasias Esofágicas/cirurgia , Esofagectomia/métodos , Constrição Patológica/cirurgia , Carcinoma de Células Escamosas do Esôfago/cirurgia , Anastomose Cirúrgica/métodos , Grampeamento Cirúrgico/efeitos adversos
14.
Dis Esophagus ; 36(5)2023 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-36222069

RESUMO

Anastomotic leakage after esophagectomy is one of the most feared complications, which results in increased morbidity and mortality. Our aim was to evaluate the impact of a powered circular stapler on complications after esophagectomy with intrathoracic anastomosis for esophageal cancer. Between May 2019 and July 2021, all consecutive oesophagectomies for cancer with intrathoracic anastomosis in a high-volume center were included in this retrospective study. Surgeons were free to choose either a manual or a powered circular stapler. Preoperative characteristics and postoperative complications were recorded in a prospective database, according to EsoData. Propensity score matching (age, body mass index, Eastern cooperative oncology group (ECOG) performance and neoadjuvant therapy) was conducted to reduce potential confounding. We included 128 patients. Powered and manual circular staplers were used in 62 and 66 patients, respectively. Fewer anastomotic leakages were observed with the powered stapler group (OR = 7.3 (95%CI: 1.58-33.7); [3.2% (n = 2) vs 19.7% (n = 13), respectively; p = 0.004]). After propensity score matching, this remained statistically significant (OR = 8.5 (95%CI: 1.80-40.1); [4.1% (n = 2) vs 20.4% (n = 10), respectively; p = 0.013]). Additionally, anastomotic diameter was significantly higher with the powered stapler (median: 29 mm (63.3%) vs 25 mm (57.1%), respectively; p < 0.0001). There was no significant difference in comprehensive complication index (p = 0.146). A decreased mean length of stay was observed in the powered stapler group (11.1 vs 18.7 days respectively; p = 0.022). Postoperative anastomotic leakage after esophageal resection was significantly reduced after the introduction of the powered circular stapler, consequently resulting in a reduced length of stay. Further evaluation on long-term strictures and quality of life are warranted to support these results.


Assuntos
Fístula Anastomótica , Neoplasias Esofágicas , Humanos , Fístula Anastomótica/etiologia , Fístula Anastomótica/prevenção & controle , Fístula Anastomótica/cirurgia , Estudos Retrospectivos , Qualidade de Vida , Grampeadores Cirúrgicos/efeitos adversos , Anastomose Cirúrgica/efeitos adversos , Anastomose Cirúrgica/métodos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Neoplasias Esofágicas/cirurgia , Neoplasias Esofágicas/complicações , Esofagectomia/efeitos adversos , Esofagectomia/métodos , Pontuação de Propensão
15.
Surg Endosc ; 37(2): 1021-1030, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36097097

RESUMO

BACKGROUND: Laparoscopic total gastrectomy for gastric cancer is still a demanding operation because of technical difficulties, especially of intracorporeal esophago-jejunal anastomosis. METHODS: We introduced a newly designed method of anvil placement of circular stapling devices (CS) for laparoscopic esophagojejunostomy (EJS). A small incision was made on the anterior wall of the stomach, from which the anvil was inserted into the stomach and proceeded to the thoracic esophagus. Then, the abdominal esophagus was transected by a linear stapler, and the anvil into the esophagus was drawn back to the esophageal stump by pulling out the cotton tape pre-attached to the anvil. Intracorporeal EJS by Roux-en-Y reconstruction was performed by CS inserted into the abdominal cavity from the umbilical wound. RESULTS: A total of consecutive 200 gastric cancer patients underwent laparoscopic total gastrectomy using this method. There was no operative mortality. Anastomotic complications occurred in 12 cases (6.0%): 9 cases of stenosis (4.5%) and 3 cases of bleedings (1.5%). Anastomotic leakage was not observed. As for non-anastomotic complications, there occurred 2 pulmonary complications (1.0%), 3 pancreatic leakages (1.5%), and 8 bowel obstructions due to internal hernia (4.0%). With a median follow-up period of 47.1 months, 5-year overall survival for assessable patients (n = 193) was 60.3% (95% CI 52.6-67.2). The total rate of peritoneal recurrence was 9.8%. CONCLUSION: Our new method of anvil placement for laparoscopic EJS with CS is safe and feasible with favorable survival outcomes. It eliminates the need for suturing, and will promote the clinical application of laparoscopic total gastrectomy for gastric cancer. CLINICAL TRIALS: UMIN000046119.


Assuntos
Laparoscopia , Neoplasias Gástricas , Humanos , Neoplasias Gástricas/cirurgia , Grampeamento Cirúrgico/métodos , Anastomose Cirúrgica/métodos , Laparoscopia/métodos , Gastrectomia/métodos , Jejuno/cirurgia
16.
Esophagus ; 20(1): 63-71, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36042126

RESUMO

BACKGROUND: Anastomotic leakage of cervical esophagogastrostomy following radical esophagectomy for esophageal cancer has reduced over time; however, postoperative anastomotic stricture still occurs at a considerably high rate. We developed a novel method of circular-stapled esophagogastrostomy by employing the keyhole procedure, which uses a linear stapler to enlarge the anastomotic opening made with a circular stapler (CS). METHODS: We retrospectively reviewed 70 patients with esophageal cancer who underwent transthoracic esophagectomy and reconstruction via cervical CS-mediated anastomosis with or without the keyhole procedure between 2018 and 2020. The primary outcome was postoperative anastomotic stricture incidence within 180 days after surgery. RESULTS: Among 70 patients, 22 underwent the keyhole procedure (CS + K group) and the remaining did not (CS group). No differences were observed in patients' age, sex, body mass index, performance status, American Society of Anesthesiologists physical status, Charlson's comorbidity index, tumor histological type, tumor location, clinical stage, or preoperative treatment. A smaller stapler was used in the CS + K group (p < 0.001). Incidence of anastomotic stricture was significantly different (CS vs. CS + K, 18.8 vs. 0%, p = 0.049), especially when a 21 or 23 mm CS was used (CS vs. CS + K, 50.0 vs. 0%, p = 0.005). Univariate analysis confirmed that CS ≤ 23 without keyhole was a significant risk factor (p = 0.001). CONCLUSIONS: The keyhole procedure could be a simple and useful alternative technique that reduces the risk of stricture formation in cervical esophagogastric anastomosis, especially when using the smaller-sized CS.


Assuntos
Neoplasias Esofágicas , Esofagectomia , Humanos , Esofagectomia/efeitos adversos , Esofagectomia/métodos , Constrição Patológica/etiologia , Constrição Patológica/cirurgia , Estudos Retrospectivos , Grampeamento Cirúrgico/efeitos adversos , Grampeamento Cirúrgico/métodos , Neoplasias Esofágicas/patologia , Complicações Pós-Operatórias/etiologia
17.
J Clin Med ; 11(23)2022 12 02.
Artigo em Inglês | MEDLINE | ID: mdl-36498752

RESUMO

(1) Background: Minimally invasive oesophagectomy (MIE) with intrathoracic anastomosis is increasingly used in treating patients with oesophageal cancer. Anastomotic leakage (AL) remains a critical perioperative complication, despite recent advances in surgical techniques. It remains unclear to what extent the size of the circular stapler (CS), a 25 mm CS or a bigger CS, may affect the incidence of AL. This study aimed to evaluate whether the CS size in oesophagogastrostomy affects the postoperative AL rates and related morbidity in MIE. (2) Methods: We conducted a retrospective review of consecutive patients who had undergone thoracic MIE between August 2014 and July 2019 using a CS oesophagogastric anastomosis at the level of the Vena azygos. The patients were grouped according to CS size (mm): small-sized (SS25) and large-sized (LS29). The patient demographics, data regarding morbidity, and clinical outcomes were compared. The primary outcome measure was the AL rate related to the stapler size. (3) Results: A total of 119 patients were included (SS25: n = 65; LS29: n = 54). Except for the distribution of squamous cell carcinoma, the demographics were similar in each group. The AL rate was 3.7% in the LS29 group and 18.5% in the SS25 group (p = 0.01). The major morbidity (CD ≥ 3a) was significantly more frequent in the SS25 group compared with the LS29 group (p = 0.02). CS size, pulmonary complications, and cardiovascular disease were independent risk factors for AL in the multivariate analysis. (4) Conclusions: A 29 mm CS is associated with significantly improved surgical outcomes following standard MIE at the level of the azygos vein and should be conducted whenever technically feasible.

18.
Int J Colorectal Dis ; 37(12): 2501-2510, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36385574

RESUMO

PURPOSE: Circular staplers for colorectal anastomoses significantly ameliorated post-operative outcomes after rectal resection. The more recent three-row technology was conceived to improve anastomotic resistance and, thus, lower the incidence of anastomotic complications. The aim of this study was to evaluate potential advantages of three-row circular staplers (Three-CS) on anastomotic leakage (AL), stenosis (AS), and hemorrhage (AH) rates after rectal resection as compared to two-row circular staplers (Two-CS). METHODS: All rectal resections for rectal cancer between 2016 and 2021 were retrospectively included. Patients were classified according to the circular stapler employed in Two-CS and Three-CS cohorts. AL, AS, and AH rates were compared between the two populations. Additionally, the prognostic role of the type of circular stapler on AL onset was evaluated. RESULTS: Three-hundred and seventy-five patients underwent a rectal resection with an end-to-end anastomosis during the study period: 197 constituted the Two-CS group and 178 the Three-CS cohort. AL rate was 6.7%, significantly higher in the Two-CS group (19-9.6%) as compared to the Three-CS cohort (6-3.4%) (p = 0.01). No difference was noted in terms of AL severity. Although not statistically significant, a lower incidence rate of AL was evidenced even in the subset of patients with low rectal cancers (4.5% vs 12.5% in the two-row cohort; p = 0.33). At the multivariate analysis, Two-CS was a negative prognostic factor for AL onset (OR: 2.63; p = 0.03). No difference was noted between the two groups in terms of AS and AH. CONCLUSION: Three-row CSs significantly decrease the rate of AL after rectal resection. Further multicenter controlled trials are still needed to confirm the advantages of three-row CSs on anastomotic complications.


Assuntos
Protectomia , Neoplasias Retais , Humanos , Estudos Retrospectivos , Anastomose Cirúrgica/efeitos adversos , Protectomia/efeitos adversos , Reto/cirurgia , Fístula Anastomótica/cirurgia , Neoplasias Retais/cirurgia , Neoplasias Retais/complicações
19.
ANZ J Surg ; 92(11): 2896-2900, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36128948

RESUMO

BACKGROUND: In the laparoscopic Roux-en-Y gastric bypass procedure, the gastrojejunal stoma is constructed with either a circular (CSD) or a linear stapling device (LSD). The diameter of the stoma following stapling with the 21 mm CSD is expected to be approximately 12 mm (diameter of the anvil). Measuring the stoma diameter after linear stapling is a little more complex since the remaining opening in the linear anastomosis is closed by hand. The aim of this prospective randomized study was to follow up on changes in the diameter of gastrojejunal stomata after laparoscopic Roux-en-Y gastric bypass using either a CSD or an LSD between that at construction and at a long-term follow-up of 12-72 months later. METHODS: Twenty patients were randomly assigned to gastrojejunostomy with either a 21 mm CSD or a 45 mm LSD. Directly after completion of the surgery, the diameter of the gastrojejunal stoma was measured using a Fogarty occlusion catheter and again at follow-up 12-72 months later. RESULTS: Five patients were lost for follow-up, and 15 patients remained. The mean diameter of the CSD stomata at construction was 19.3 ± 5.3 mm (mean ± SD) and increased to 26.4 ± 6.6 mm at follow-up after a mean of 46 months (P = 0.02). The corresponding figures for the LSD stomata were 26.2 ± 4.1 mm, increasing to 32.7 ± 3.0 mm also after a mean follow-up of 46 months (P = 0.03). CONCLUSIONS: The mean diameter of the circular stapled gastrojejunostomy stomata at construction was 20 mm, that is, considerably larger than the 12 mm expected. After a mean of 5 years, the mean diameter had increased by 37%. The mean diameter of the linear stapled stomata increased by 25%.


Assuntos
Derivação Gástrica , Laparoscopia , Obesidade Mórbida , Humanos , Anastomose em-Y de Roux/métodos , Seguimentos , Derivação Gástrica/métodos , Laparoscopia/métodos , Obesidade Mórbida/cirurgia , Estudos Prospectivos , Grampeamento Cirúrgico/métodos
20.
Cost Eff Resour Alloc ; 20(1): 45, 2022 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-36045434

RESUMO

AIMS: This study aimed to examine the economic and clinical benefits of a new powered circular stapler for left-sided colorectal construction in China. METHODS: A decision analysis model was constructed for a cohort of adult patients who underwent left-sided colorectal anastomoses, using either the Echelon Circular Powered (ECP) stapler) or the conventional manual circular staplers (MCS). The complications rates and healthcare resource utilization in the ECP cohort were obtained from the single-arm ECP trial (NCT03326895). For the MCS cohort, retrospective data from 20 Chinese hospitals were analyzed. Listing prices were used to estimate the costs of the staplers in China. Propensity score matching (PSM) was employed to adjust for the imbalance between the two cohorts. Anastomotic leak rate, length of stay (LOS), 90-day readmission rate, and direct medical costs were used for the decision analysis model parameters. A budget impact analysis was conducted to compare the total hospitalization expenditure between ECP and manual circular staplers from the hospital's perspective in China. RESULTS: Assuming 100 procedures per year, the anastomotic leak rate was 1.79 and 29.76 per 100 procedures in the ECP and MCS cohorts, respectively. LOS was 1,426.91 days in the ECP cohort, compared to 1,702.38 days in the MCS cohort. The 90-day readmission rate was also lower in the ECP cohort than the MCS cohort (19.10 vs. 26.19 per 100 procedures). For the 100 procedures, the annual total hospitalization costs for left-sided colorectal anastomosis were reduced from ¥7,152,251 using manual circular staplers to ¥6,919,306 using ECP. Despite a higher acquisition cost of ECP compared to the manual staplers (¥711,200 vs. ¥441,700), an annual saving of ¥232,945in the total cost resulted from lower rates of complications and shorter LOS. Sensitivity analyses presented consistent savings using ECP, and the ECP cost and cost of the index hospitalization with anastomotic leak were found the most influencing factors. CONCLUSIONS: There were clinical and economic benefits of ECP, compared to manual circular staplers for left-sided colorectal anastomoses. Further direct comparative studies on the use of ECP in practice in Chinese hospital settings are warranted.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...