Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Int Arch Otorhinolaryngol ; 23(2): 137-141, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30956695

RESUMO

Introduction Preoperative temporal bone imaging studies have been routinely performed prior to cochlear implantation. Radiologists need to report these examinations with special focus on the surgeon's expectations. Objectives To provide a basic structured format, in the form of a checklist, for reporting preoperative computed tomography (CT) and to its clinical impact on operative findings. Methods The preoperative temporal bone CT scans of 47 patients were analyzed and reported according to the proposed checklist. Intraoperative assessment of mastoidectomy, posterior tympanotomy and round window access was done by the surgeon in a blinded fashion and were correlated with the radiological findings to assess its significance. Results The proposed radiological checklist was reliable in assessing operative difficulty during cochlear implantation. Contracted mastoid and lower tegmen position were associated with a greater difficulty of the cortical mastoidectomy. Presence of an air cell around the facial nerve (FN) was predictive of easier facial recess access exposure. Facial nerve location and posterior external auditory canal (EAC) wall inclination were predictive of difficult round window (RW) accessibility. Conclusion Certain parameters on the preoperative temporal bone CT scan may be useful in predicting potential difficulties encountered during the key steps involved in cochlear implant surgery.

2.
Int. arch. otorhinolaryngol. (Impr.) ; 23(2): 137-141, 2019. ilus, tab, graf
Artigo em Inglês | LILACS | ID: biblio-1010196

RESUMO

Introduction: Preoperative temporal bone imaging studies have been routinely performed prior to cochlear implantation. Radiologists need to report these examinations with special focus on the surgeon's expectations. Objectives: To provide a basic structured format, in the form of a checklist, for reporting preoperative computed tomography (CT) and to its clinical impact on operative findings. Methods: The preoperative temporal bone CT scans of 47 patients were analyzed and reported according to the proposed checklist. Intraoperative assessment of mastoidectomy, posterior tympanotomy and round window access was done by the surgeon in a blinded fashion and were correlated with the radiological findings to assess its significance. Results: The proposed radiological checklist was reliable in assessing operative difficulty during cochlear implantation. Contracted mastoid and lower tegmen position were associated with a greater difficulty of the cortical mastoidectomy. Presence of an air cell around the facial nerve (FN) was predictive of easier facial recess access exposure. Facial nerve location and posterior external auditory canal (EAC) wall inclination were predictive of difficult round window (RW) accessibility. Conclusion: Certain parameters on the preoperative temporal bone CT scan may be useful in predicting potential difficulties encountered during the key steps involved in cochlear implant surgery (AU)


Assuntos
Lactente , Pré-Escolar , Criança , Adulto , Osso Temporal/diagnóstico por imagem , Cuidados Pré-Operatórios , Implante Coclear , Janela da Cóclea/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Estudos Prospectivos , Estudos de Coortes , Orelha/diagnóstico por imagem , Lista de Checagem
3.
Int. arch. otorhinolaryngol. (Impr.) ; 20(4): 353-358, Oct.-Dec. 2016. tab, graf
Artigo em Inglês | LILACS | ID: biblio-828917

RESUMO

Abstract Introduction The preservation of residual hearing is currently an important challenge for cochlear implant surgeries. Indeed, if patients exhibit functional hearing after cochlear implantation, they can benefit from the combination of acoustical stimulation, usually in the low-frequencies and electrical stimulation in the high-frequencies. This combined mode of stimulation has proven to be beneficial both in terms of speech perception and of sound quality. Finding the right procedures for conducting softsurgeries and designing electrode arrays dedicated to hearing preservation is an open issue. Objective The objective of this study is to evaluate the combination of a soft-surgery procedure implicating round-window insertion and the use of dexamethasone and hyaluronic acid during surgery, with the use of a specifically designed straight soft electrode array, on hearing preservation in patients with functional hearing in the low frequencies. Methods This pre-clinical trial was conducted on seven patients with residual hearing in the low frequencies. The surgical method used employed a round window insertion and the use of topical dexamethasone. Results The soft-surgery protocol could be successfully followed in five patients. In this group, the average hearing threshold shift compared with pre-operative values was of 18.7 þ/ 16.1 dB HL up to 500 Hz and 15.7 þ/ 15.1 up to 1 kHz, demonstrating satisfying levels of hearing preservation. Conclusion We were able to demonstrate the possibility of preserving residual hearing in most of the patients using the EVO electrode. Significant residual hearing preservation levels were was obtained when a soft surgical approach involving round window insertion, dexamethasone and hyaluronic use during the surgery.

4.
Int Arch Otorhinolaryngol ; 20(4): 353-358, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27746839

RESUMO

Introduction The preservation of residual hearing is currently an important challenge for cochlear implant surgeries. Indeed, if patients exhibit functional hearing after cochlear implantation, they can benefit from the combination of acoustical stimulation, usually in the low-frequencies and electrical stimulation in the high-frequencies. This combined mode of stimulation has proven to be beneficial both in terms of speech perception and of sound quality. Finding the right procedures for conducting soft-surgeries and designing electrode arrays dedicated to hearing preservation is an open issue. Objective The objective of this study is to evaluate the combination of a soft-surgery procedure implicating round-window insertion and the use of dexamethasone and hyaluronic acid during surgery, with the use of a specifically designed straight soft electrode array, on hearing preservation in patients with functional hearing in the low frequencies. Methods This pre-clinical trial was conducted on seven patients with residual hearing in the low frequencies. The surgical method used employed a round window insertion and the use of topical dexamethasone. Results The soft-surgery protocol could be successfully followed in five patients. In this group, the average hearing threshold shift compared with pre-operative values was of 18.7 +/- 16.1 dB HL up to 500 Hz and 15.7 +/- 15.1 up to 1 kHz, demonstrating satisfying levels of hearing preservation. Conclusion We were able to demonstrate the possibility of preserving residual hearing in most of the patients using the EVO electrode. Significant residual hearing preservation levels were was obtained when a soft surgical approach involving round window insertion, dexamethasone and hyaluronic use during the surgery.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA