1.
Semina Ci. agr. ; 37(2): 639-650, mar.-abr. 2016. tab, graf
Artigo em Inglês | VETINDEX | ID: vti-23444

RESUMO

The aim of the present study was to evaluate hydraulic characteristics such as manufacturing and flow variation coefficient, characteristic equation of self-compensating emitters and the variation between nominal flow and that obtained by the emitter equation using waters of different salt concentrations. The research was conducted in the greenhouse of the Academic Unit of the Agricultural Engineering, Federal University of Campina Grande-PB. Treatments consisted of five salinity levels in the irrigation water (ECwi) (0.6; 1.5; 2.5; 3.5 and 4.5 dS m-1 at 25 ° C) and four working pressures (60, 100, 140, and 160 kPa), with three replicates. The flow variations of emitters were considered small over time, being within recommendation of ± 7% of the nominal flow with “x” exponent values between 0.02 and 0.09, as recommended by the manufacturer, which was classified as self-compensating. The manufacturing and flow variation coefficients were considered excellent in all evaluations and the operating time did not influence the hydraulic performance of emitters. At pressure of 60 kPa and electric conductivity of 0.6 dS m-1, flow rates near values provided by the manufacturer and more economically viable to the farmer were obtained.(AU)


Objetivou-se, com o presente estudo, avaliar as características hidráulicas, como coeficiente de variação de fabricação e vazão, equação característica do emissor autocompensante e a variação entre a vazão nominal e a obtida pela equação do emissor utilizando águas de diferentes concentrações salinas. A pesquisa foi conduzida na casa de vegetação da Unidade Acadêmica de Engenharia Agrícola, Universidade Federal de Campina Grande-PB. Os tratamentos foram compostos por cinco níveis de salinidade da água de irrigação (CEai) (0,6; 1,5; 2,5; 3,5 e 4,5 dS m-1 a 25 °C) e quatro pressões de serviço (60, 100, 140, e 160 kPa), com três repetições. As variações de vazão dos emissores foram consideradas pequenas ao longo do tempo, de modo que estavam dentro da recomendação de ± 7% da vazão nominal, com valores de expoente “x” entre 0,02 e 0,09, segundo recomendação do fabricante, que os classificou como autocompensantes . Os Coeficientes de variação de fabricação e de vazão foram considerados excelentes em todas as avaliações e o tempo de funcionamento não influenciou no desempenho hidráulico dos emissores. Na pressão de 60 kPa associada à condutividade elétrica da água de 0,6 dS m-1, obtiveram-se vazões dos emissores mais próximas da declarada pelo fabricante e a mais economicamente viáveis ao produtor.(AU)


Assuntos
Irrigação Agrícola , Medição de Vazão , Águas Salinas
2.
Semina ciênc. agrar ; 37(2): 639-650, 2016. tab, graf
Artigo em Inglês | VETINDEX | ID: biblio-1500303

RESUMO

The aim of the present study was to evaluate hydraulic characteristics such as manufacturing and flow variation coefficient, characteristic equation of self-compensating emitters and the variation between nominal flow and that obtained by the emitter equation using waters of different salt concentrations. The research was conducted in the greenhouse of the Academic Unit of the Agricultural Engineering, Federal University of Campina Grande-PB. Treatments consisted of five salinity levels in the irrigation water (ECwi) (0.6; 1.5; 2.5; 3.5 and 4.5 dS m-1 at 25 ° C) and four working pressures (60, 100, 140, and 160 kPa), with three replicates. The flow variations of emitters were considered small over time, being within recommendation of ± 7% of the nominal flow with “x” exponent values between 0.02 and 0.09, as recommended by the manufacturer, which was classified as self-compensating. The manufacturing and flow variation coefficients were considered excellent in all evaluations and the operating time did not influence the hydraulic performance of emitters. At pressure of 60 kPa and electric conductivity of 0.6 dS m-1, flow rates near values provided by the manufacturer and more economically viable to the farmer were obtained.


Objetivou-se, com o presente estudo, avaliar as características hidráulicas, como coeficiente de variação de fabricação e vazão, equação característica do emissor autocompensante e a variação entre a vazão nominal e a obtida pela equação do emissor utilizando águas de diferentes concentrações salinas. A pesquisa foi conduzida na casa de vegetação da Unidade Acadêmica de Engenharia Agrícola, Universidade Federal de Campina Grande-PB. Os tratamentos foram compostos por cinco níveis de salinidade da água de irrigação (CEai) (0,6; 1,5; 2,5; 3,5 e 4,5 dS m-1 a 25 °C) e quatro pressões de serviço (60, 100, 140, e 160 kPa), com três repetições. As variações de vazão dos emissores foram consideradas pequenas ao longo do tempo, de modo que estavam dentro da recomendação de ± 7% da vazão nominal, com valores de expoente “x” entre 0,02 e 0,09, segundo recomendação do fabricante, que os classificou como autocompensantes . Os Coeficientes de variação de fabricação e de vazão foram considerados excelentes em todas as avaliações e o tempo de funcionamento não influenciou no desempenho hidráulico dos emissores. Na pressão de 60 kPa associada à condutividade elétrica da água de 0,6 dS m-1, obtiveram-se vazões dos emissores mais próximas da declarada pelo fabricante e a mais economicamente viáveis ao produtor.


Assuntos
Irrigação Agrícola , Medição de Vazão , Águas Salinas