Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Quant Imaging Med Surg ; 13(5): 3279-3287, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-37179943

RESUMO

Background: Pancreatic perfusion computed tomography (CT) imaging is increasingly used for neoplastic grading, predicting prognosis, and evaluating the response to therapy. To optimize the clinical pancreatic CT perfusion imaging methods, we evaluated 2 different CT scanning protocols concerning pancreas perfusion parameters. Methods: A retrospective study was conducted on 40 patients who underwent whole pancreas CT perfusion scanning in The First Affiliated Hospital of Zhengzhou University. Of these 40 patients, 20 patients in group A underwent continuous perfusion scanning, while 20 patients in group B underwent intermittent perfusion scanning. For group A, continuous axial scanning was performed 25 times, and the total scan time was 50 s. For group B, arterial phase helical perfusion scanning was performed 8 times, and then venous phase helical perfusion scanning was performed 15 times, with a total scan time of 64.6 to 70.0 s. A comprehensive list of perfusion parameters between different parts of the pancreas and the 2 groups were compared. The effective radiation dose for the 2 scanning methods was analyzed. Results: The parameter of the mean slope of increase (MSI) at different pancreatic parts in group A differed (P=0.028). The pancreas head had the lowest value, and the tail had the highest (about a 20% difference). In group A compared to group B, the blood volume of the pancreatic head was smaller (15.256±2.925 vs. 16.953±3.602), the positive enhanced integral was smaller (0.307±0.050 vs. 0.344±0.060) and the permeability surface was larger (34.205±9. 612 vs. 24.377±8.413); the blood volume of the pancreatic neck was smaller (13.940±2.691 vs. 17.173±3.918), the positive enhanced integral was smaller (0.304±0.088 vs. 0.361±0.051) and the permeability surface was larger (34.898±11.592 vs. 25. 794±8.149); the blood volume of the pancreatic body was smaller (16.142±4.006 vs. 18.401±2.513), the positive enhanced integral was smaller (0.305±0.093 vs. 0.342±0.048) and the permeability surface was larger (28.861±10.448 vs. 22.158±6. 017); the blood volume of the pancreatic tail was smaller (16.446±3.709 vs. 17.374±3.781), the positive enhanced integral was smaller (0.304±0.057 vs. 0.350±0.073) and the permeability surface was larger (27.823±8.228 vs. 21.509±7.768) (P<0.05). The effective radiation dose in the intermittent scan mode was slightly lower at 16.657±2.259 mSv than in the continuous scan mode (17.973±3.698 mSv). Conclusions: Different CT scanning intervals had a significant influence on whole pancreas blood volume, permeability surface, and positive enhanced integral. These demonstrate the high sensitivity of intermittent perfusion scanning for identifying perfusion abnormalities. Therefore, for the diagnosis of pancreatic diseases, intermittent pancreatic CT perfusion may be more advantageous.

2.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-480276

RESUMO

Objective To evaluate the muscle mass in elderly patients with inguinal hernia using CT scan.Methods 30 male (age 70-90 years) hospitalized patients scheduled to receive surgery for inguinal hernia were selected into study group, 10 male health volunteers (40-50 years) were involved in adult control group, and 10 men of the same age as the study receiving annual physical examination were enrolled as elderly control group.General information were recorded;CT scanning of the stomach muscles and thigh muscles were conducted, and the muscle area was calculated using a special software.Results The index of grip strength in the study group was significantly lower than the adult control group [(36.44 ± 14.15) kg vs.(77.30 ± 22.69) kg, P =0.001], the calf circumference in the study group was significantly less than the adult control group [(25.18 ±2.31) cm vs.(27.62 ±2.33) cm, P =0.006].There was no significant difference in L3 abdominal area, subcutaneous fat area, abdominal fat area, and vertical spinal muscular volume between the study group and the adult control group;while the L3 abdominal muscle area and vertical spinal muscular mass was significantly less in the study group than in the adult control group [(12 094.23 ± 1 970.30) mm2 vs.(17462.00±1 600.58) mm2, P=0.001;(1 642.60±266.90) mm2 vs.(2 003.50±350.91) mm2,P =0.007].L3 skeletal muscle index of the study group was 50.64 ±7.52 and 66.7% (20/30) of the study group had sarcopenia (≤52.4%).The CT findings of abdominal muscle of the study group were not significantly different from those of the elderly control group.The thigh muscle mass in the study group was significantly less than that in the control group (P =0.001), but there was no significant inter-group difference in thigh fat and femur areas (P > 0.05).Conclusion The muscle mass and strength in elderly patients with inguinal hernia are significantly lower than those of adult controls, for which CT scan can be applied for assessment.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...