Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
1.
Korean J Anesthesiol ; 77(1): 122-132, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37211766

RESUMO

BACKGROUND: The bispectral index (BIS) may be unreliable to gauge anesthetic depth when dexmedetomidine is administered. By comparison, the electroencephalogram (EEG) spectrogram enables the visualization of the brain response during anesthesia and may prevent unnecessary anesthetic consumption. METHODS: This retrospective study included 140 adult patients undergoing elective craniotomy who received total intravenous anesthesia using a combination of propofol and dexmedetomidine infusions. Patients were equally matched to the spectrogram group (maintaining the robust EEG alpha power during surgery) or the index group (maintaining the BIS score between 40 and 60 during surgery) based on the propensity score of age and surgical type. The primary outcome was the propofol dose. Secondary outcome was the postoperative neurological profile. RESULTS: Patients in the spectrogram group received significantly less propofol (1585 ± 581 vs. 2314 ± 810 mg, P < 0.001). Fewer patients in the spectrogram group exhibited delayed emergence (1.4% vs. 11.4%, P = 0.033). The postoperative delirium profile was similar between the groups (profile P = 0.227). Patients in the spectrogram group exhibited better in-hospital Barthel's index scores changes (admission state: 83.6 ± 27.6 vs. 91.6 ± 17.1; discharge state: 86.4 ± 24.3 vs. 85.1 ± 21.5; group-time interaction P = 0.008). However, the incidence of postoperative neurological complications was similar between the groups. CONCLUSIONS: EEG spectrogram-guided anesthesia prevents unnecessary anesthetic consumption during elective craniotomy. This may also prevent delayed emergence and improve postoperative Barthel index scores.


Assuntos
Anestesia Intravenosa , Craniotomia , Dexmedetomidina , Eletroencefalografia , Propofol , Adulto , Humanos , Anestésicos Intravenosos , Dexmedetomidina/administração & dosagem , Pontuação de Propensão , Propofol/administração & dosagem , Estudos Retrospectivos
2.
Indian J Crit Care Med ; 27(11): 795-800, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37936795

RESUMO

Purpose: Monitoring and improving sleep quality may help recovery from major illness. Polysomnography is a gold standard for measuring sleep quality, but routine use is not practical. The goal of this study is to investigate the diagnostic accuracy of an alternative monitor, the Bispectral Index (BIS), for evaluating the quality of sleep-in postoperative patients in the intensive care unit (ICU). Study design: An observational study. Materials and methods: Patients admitted to postoperative ICU after elective major noncardiac surgery were monitored with both BIS and PSG during the first night. The temporally synchronized data from both monitors were obtained for measurement of the association. Clinical outcomes were compared between patients with different postoperative sleep quality. Results: Thirty-three patients were enrolled in this study. For determining the average BIS index associated with good postoperative sleep quality, receiver operating characteristics (ROC) curve was generated. Area under the ROC curve (AUC) was 0.65. The cutoff with best discriminability was 75 with a sensitivity of 68% and a specificity of 56%. Compared with those with good and poor postoperative sleep quality, there were no differences in main postoperative outcomes including duration of mechanical ventilation and ICU stay. Although the quality of sleep after surgery of all subjects with postoperative delirium was poor, the incidence of delirium between the groups did not significantly differ (0% vs 10.3%; p = 0.184). Conclusion: The monitoring of BIS is a viable tool for evaluating sleep quality in mechanically ventilated patients in the postoperative ICU with acceptable precision. Trial registration: www.clinicaltrials.in.th, TCTR20200310005. How to cite this article: Sirilaksanamanon P, Thawitsri T, Charuluxananan S, Chirakalwasan N. Diagnostic Value of the Bispectral Index to Assess Sleep Quality after Elective Surgery in Intensive Care Unit. Indian J Crit Care Med 2023;27(11):795-800.

3.
Rev. mex. anestesiol ; 46(2): 121-124, abr.-jun. 2023. graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1508630

RESUMO

Resumen: La anestesiología cuenta con una nueva generación de monitores de la profundidad anestésica como Narcotrend, SedLine y el índice biespectral; con un procesador del electroencefalograma llamado espectrograma o espectrografía. Tras la obtención del electroencefalograma, se procesa para graficar en tres dimensiones: la frecuencia, el tiempo y la potencia en una escala de colores, con lo que se obtiene la matriz de densidad espectral (DSA, por sus siglas en inglés). El objetivo de esta revisión narrativa es ilustrar los efectos de los anestésicos más comunes en el espectrograma y hacer una breve revisión de su huella en el electroencefalograma.


Abstract: Anesthesiology has a new generation of anesthetic depth monitors such as Narcotrend, SedLine and Bispectral Index; with an electroencephalogram processor called a spectrogram or spectrograph. After obtaining the electroencephalogram, it is processed to graph three dimensions: frequency, time, and power on a color scale, obtaining the DSA (density spectral array). The objective of this narrative review is to illustrate the effects of the most common anesthetics on the spectrogram and to briefly review their signature on the electroencephalogram.

4.
Diagnostics (Basel) ; 13(10)2023 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-37238272

RESUMO

Purpose Intravenous sedation has been well accepted to allow dental restoration in uncooperative children while avoiding aspiration and laryngospasm; however, intravenous anesthetics such as propofol may lead to undesired effects such as respiratory depression and delayed recovery. The use of the bispectral index system (BIS), a monitoring system reflective of the hypnotic state, is con-troversial in the reduction in the risk of respiratory adverse events (RAEs), recovery time, the in-travenous drug dosage, and post-procedural events. The aim of the study is to evaluate whether BIS is advantageous in pediatric dental procedures. Methods A total of 206 cases, aged 2-8 years, receiving dental procedures under deep sedation with propofol using target-controlled infusion (TCI) technique were enrolled in the study. BIS level was not monitored in 93 children whereas it was for 113 children, among which BIS values were maintained between 50-65. Physiological variables and adverse events were recorded. Statistical analysis was conducted using Chi-square, Mann Whitney U, Independent Samples t and Wilcoxon signed tests, with a p value of <0.05 considered to be statistically significant. Results Although no statistical significance in the post-discharge events and total amount of propofol used was observed, a clear significance was identified in periprocedural adverse events (hypoxia, apnea, and recurrent cough, all p value < 0.05) and discharge time (63.4 ± 23.2 vs. 74.5 ± 24.0 min, p value < 0.001) between these two groups. Conclusions The application of BIS in combination with TCI may be beneficial for young children undergoing deep sedation for dental procedures.

5.
Rev. esp. cardiol. (Ed. impr.) ; 75(12): 992-1000, dic. 2022. ilus, tab, graf
Artigo em Espanhol | IBECS | ID: ibc-212932

RESUMO

Introducción y objetivos: La disfunción miocárdica contribuye a la mortalidad precoz (24-72 horas) de los supervivientes de parada cardiaca (PC). Actualmente, la decisión de implantar un dispositivo de soporte circulatorio en este contexto se toma con información limitada acerca del potencial de recuperación neurológica (PRN) del paciente, lo que en muchas ocasiones termina en infratratamiento. Por tanto, requerimos de herramientas accesibles y fiables que añadan información sobre el PRN y ayuden a establecer planes individualizados de escalada terapéutica. Métodos: Se recogieron valores de índice biespectral (BIS) y tasa de supresión (TS) en supervivientes de una PC sometidos a control de la temperatura corporal. La función neurológica se evaluó con la escala Cerebral Performance Category (CPC). Resultados: Se incluyeron 340 pacientes. En la primera evaluación neurológica completa, 211 (62,1%) alcanzaron buen pronóstico (CPC 1-2). Los valores de BIS fueron significativamente mayores y los de TS menores, en pacientes con CPC 1-2. Un BIS promedio> 26 en las primeras 12 horas predijo buena evolución neurológica (sensibilidad 89,5%; especificidad 75,8%; AUC=0,869), mientras que una TS promedio> 24 en las primeras 12 horas predijo mala evolución o CPC 3-5 (sensibilidad 91,5%; especificidad 81,8%; AUC=0,906). Los valores horarios de BIS/TS mostraron buena capacidad predictiva (AUC> 0,85) desde la 2.a hora para TS y 4.a para BIS. Conclusiones: El BIS/TS permiten estimar el PRN tras una PC. Este hallazgo puede contribuir a crear conciencia con respecto a evitar la limitación de escalada terapéutica en pacientes potencialmente recuperables.(AU)


Introduction and objectives: Myocardial dysfunction contributes to early mortality (24-72 hours) among survivors of a cardiac arrest (CA). The benefits of mechanical support in refractory shock should be balanced against the patient's potential for neurological recovery. To date, these early treatment decisions have been taken based on limited information leading mainly to undertreatment. Therefore, there is a need for early, reliable, accessible, and simple tools that offer information on the possibilities of neurological improvement. Methods: We collected data from bispectral index (BIS) and suppression ratio (SR) monitoring of adult comatose survivors of CA managed with targeted temperature management (TTM). Neurological status was assessed according to the Cerebral Performance Category (CPC) scale. Results: We included 340 patients. At the first full neurological evaluation, 211 patients (62.1%) achieved good outcome or CPC 1-2. Mean BIS values were significantly higher and median SR lower in patients with CPC 1-2. An average BIS> 26 during first 12hours of TTM predicted good outcome with 89.5% sensitivity and 75.8% specificity (AUC of 0.869), while average SR values> 24 during the first 12hours of TTM predicted poor outcome (CPC 3-5) with 91.5% sensitivity and 81.8% specificity (AUC, 0.906). Hourly BIS and SR values exhibited good predictive performance (AUC> 0.85), as soon as hour 2 for SR and hour 4 for BIS. Conclusions: BIS/SR are associated with patients’ potential for neurological recovery after CA. This finding could help to create awareness of the possibility of a better outcome in patients who might otherwise be wrongly considered as nonviable and to establish personalized treatment escalation plans.(AU)


Assuntos
Humanos , Masculino , Feminino , Parada Cardíaca , Supressão , Hipotermia Induzida , Prognóstico , Qualidade de Vida , Cardiologia , Cardiopatias , Estudos Retrospectivos
6.
J Crit Care ; 72: 154154, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36152563

RESUMO

PURPOSE: Evaluate the bispectral index (BIS) monitoring to detect delayed cerebral ischemia (DCI) after aneurysmal subarachnoid hemorrhage (aSAH). MATERIALS AND METHODS: A single-center prospective study in patients with aSAH. BIS monitoring was recorded during 25-120 min in two periods, within the initial 72 h (BIS1) and between days 4 and 6 (BIS2) from admission. The median for each exported BIS parameter was analyzed. Transcranial Doppler (TCD) sonography was simultaneously performed with BIS1 (TCD1) and BIS2 (TCD2) monitoring. A multivariate logistic regression model was built to identify the variables associated with DCI. RESULTS: Sixty-four patients were included and 16 (25%) developed DCI. During BIS2 monitoring, significant differences were found in BIS value (left, p = 0.01; right, p = 0.009), 95% spectral edge frequency (left and right, p = 0.04), and total power (left and right, p = 0.04). In multivariable analysis, vasospasm on TCD2 (OR 42.8 [95% CI 3.1-573]; p = 0.005), a median BIS2 value <85 in one or both sides (OR 6.2 [95% CI 1.28-30]; p = 0.023), and age (OR 1.08 [95% CI 1.00-1.17]; p = 0.04) were associated with the development of DCI. CONCLUSIONS: BIS value is the most useful BIS parameter for detecting DCI after aSAH. Pending further validation, BIS monitoring might be even more accurate than TCD.


Assuntos
Isquemia Encefálica , Hemorragia Subaracnóidea , Vasoespasmo Intracraniano , Humanos , Hemorragia Subaracnóidea/complicações , Vasoespasmo Intracraniano/diagnóstico por imagem , Vasoespasmo Intracraniano/etiologia , Estudos Prospectivos , Infarto Cerebral , Isquemia Encefálica/etiologia , Isquemia Encefálica/complicações
7.
Indian J Anaesth ; 66(Suppl 3): S161-S168, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35774240

RESUMO

Background and Aims: End-tidal anaesthetic gas concentration (ETAG) and bispectral index (BIS) are both used to monitor depth of anaesthesia. Maintaining an accurate depth of anaesthesia helps in early post-operative recovery. This study compared the recovery times from sevoflurane-nitrous oxide anaesthesia using ETAG monitoring with BIS monitoring. Methods: Four hundred and two patients undergoing elective surgeries under sevoflurane- nitrous oxide anaesthesia were enroled in this double blinded parallel group prospective randomised trial and allocated into two groups. The depth of anaesthesia was monitored using BIS in BIS group (n = 202) and end-tidal sevoflurane concentration (EtSevo) in ETAG group (n = 200). The time to extubation and recovery were compared between the groups. Parametric, non-parametric and categorical variables were compared using Student's 't' test, Wilcoxon's rank sum test and Chi-square test, respectively. Results: Time to extubation (min) [BIS group - 10, 5; ETAG group - 10, 5 (median, inter-quartile range, IQR), P = 0.32] and time to recovery (min) [BIS group - 14, 6; ETAG group - 13.5, 7 (median, IQR), P = 0.34] did not differ significantly between the two groups. The EtSevo concentration (vol%) was significantly higher in the BIS group at 5 min [BIS group - 1.2, 0.4; ETAG group - 1.0, 0.4 (median, IQR), P < 0.001], 30 min [BIS group - 1.1, 0.4; ETAG group - 1.0, 0.3 (median, IQR), P = 0.002] and 120 min [BIS group - 1.11 ± 0.28; ETAG group - 0.96 ± 0.27 (mean ± standard deviation), P = 0.014] after induction of anaesthesia. Conclusions: BIS and ETAG monitoring are associated with comparable recovery profiles. ETAG monitoring is associated with significantly less sevoflurane consumption.

8.
Clin Endosc ; 55(4): 558-563, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35817564

RESUMO

BACKGROUND/AIMS: Bispectral index (BIS) monitors process and display electroencephalographic data are used to assess the depth of anesthesia. This study retrospectively evaluated the usefulness of BIS monitoring during endoscopic ultrasonography (EUS). METHODS: This study included 725 consecutive patients who underwent EUS under sedation with propofol. BIS monitoring was used in 364 patients and was not used in 361. The following parameters were evaluated: (1) median dose of propofol; (2) respiratory and circulatory depression; (3) occurrence of body movements; (4) awakening score >8 at the time; and (5) awakening score 2 hours after leaving the endoscopy room. RESULTS: The BIS group received a significantly lower median dose of propofol than the non-BIS group (159.2 mg vs. 167.5 mg; p=0.015) in all age groups. For patients aged ≥75 years, the reduction in heart rate was significantly lower in the BIS group than in the non-BIS group (1.2% vs. 9.1%; p=0.023). Moreover, the occurrence of body movements was markedly lower in the BIS group than in the non-BIS group (8.5% vs. 39.4%; p<0.001). CONCLUSION: During EUS examination, BIS monitoring is useful for maintaining a constant depth of anesthesia, especially in patients 75 years of age or older.

9.
BMC Palliat Care ; 21(1): 86, 2022 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-35610644

RESUMO

BACKGROUND: Bispectral index (BIS) monitoring uses electroencephalographic data as an indicator of patients' consciousness level. This technology might be a useful adjunct to clinical observation when titrating sedative medications for palliative care patients. However, the use of BIS in palliative care generally, and in the UK in particular, is under-researched. A key area is this technology's acceptability for palliative care service users. Ahead of trialling BIS in practice, and in order to ascertain whether such a trial would be reasonable, we conducted a study to explore UK palliative care patients' and relatives' perceptions of the technology, including whether they thought its use in palliative care practice would be acceptable. METHODS: A qualitative exploration was undertaken. Participants were recruited through a UK hospice. Focus groups and semi-structured interviews were conducted with separate groups of palliative care patients, relatives of current patients, and bereaved relatives. We explored their views on acceptability of using BIS with palliative care patients, and analysed their responses following the five key stages of the Framework method. RESULTS: We recruited 25 participants. There were ten current hospice patients in three focus groups, four relatives of current patients in one focus group and one individual interview, and eleven bereaved relatives in three focus groups and two individual interviews. Our study participants considered BIS acceptable for monitoring palliative care patients' consciousness levels, and that it might be of use in end-of-life care, provided that it was additional to (rather than a replacement of) usual care, and patients and/or family members were involved in decisions about its use. Participants also noted that BIS, while possibly obtrusive, is not invasive, with some seeing it as equivalent to wearable technological devices such as activity watches. CONCLUSIONS: Participants considered BIS technology might be of benefit to palliative care as a non-intrusive means of assisting clinical assessment and decision-making at the end of life, and concluded that it would therefore be acceptable to trial the technology with patients.


Assuntos
Atitude Frente a Saúde , Monitores de Consciência , Família , Cuidados Paliativos , Pacientes , Família/psicologia , Grupos Focais , Humanos , Cuidados Paliativos/métodos , Pacientes/psicologia , Pesquisa Qualitativa
10.
Rev Esp Cardiol (Engl Ed) ; 75(12): 992-1000, 2022 Dec.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-35570124

RESUMO

INTRODUCTION AND OBJECTIVES: Myocardial dysfunction contributes to early mortality (24-72 hours) among survivors of a cardiac arrest (CA). The benefits of mechanical support in refractory shock should be balanced against the patient's potential for neurological recovery. To date, these early treatment decisions have been taken based on limited information leading mainly to undertreatment. Therefore, there is a need for early, reliable, accessible, and simple tools that offer information on the possibilities of neurological improvement. METHODS: We collected data from bispectral index (BIS) and suppression ratio (SR) monitoring of adult comatose survivors of CA managed with targeted temperature management (TTM). Neurological status was assessed according to the Cerebral Performance Category (CPC) scale. RESULTS: We included 340 patients. At the first full neurological evaluation, 211 patients (62.1%) achieved good outcome or CPC 1-2. Mean BIS values were significantly higher and median SR lower in patients with CPC 1-2. An average BIS> 26 during first 12 hours of TTM predicted good outcome with 89.5% sensitivity and 75.8% specificity (AUC of 0.869), while average SR values> 24 during the first 12 hours of TTM predicted poor outcome (CPC 3-5) with 91.5% sensitivity and 81.8% specificity (AUC, 0.906). Hourly BIS and SR values exhibited good predictive performance (AUC> 0.85), as soon as hour 2 for SR and hour 4 for BIS. CONCLUSIONS: BIS/SR are associated with patients' potential for neurological recovery after CA. This finding could help to create awareness of the possibility of a better outcome in patients who might otherwise be wrongly considered as nonviable and to establish personalized treatment escalation plans.


Assuntos
Parada Cardíaca , Hipotermia Induzida , Parada Cardíaca Extra-Hospitalar , Adulto , Humanos , Prognóstico , Hipotermia Induzida/efeitos adversos
11.
J Clin Monit Comput ; 36(1): 121-130, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33315176

RESUMO

Brain monitors which track quantitative electroencephalogram (EEG) signatures to monitor sedation levels are drug and patient specific. There is a need for robust sedation level monitoring systems to accurately track sedation levels across all drug classes, sex and age groups. Forty-four quantitative features estimated from a pooled dataset of 204 EEG recordings from 66 healthy adult volunteers who received either propofol, dexmedetomidine, or sevoflurane (all with and without remifentanil) were used in a machine learning based automated system to estimate the depth of sedation. Model training and evaluation were performed using leave-one-out cross validation methodology. We trained four machine learning models to predict sedation levels and evaluated the influence of remifentanil, age, and sex on the prediction performance. The area under the receiver-operator characteristic curve (AUC) was used to assess the performance of the prediction model. The ensemble tree with bagging outperformed other machine learning models and predicted sedation levels with an AUC = 0.88 (0.81-0.90). There were significant differences in the prediction probability of the automated systems when trained and tested across different age groups and sex. The performance of the EEG based sedation level prediction system is drug, sex, and age specific. Nonlinear machine-learning models using quantitative EEG features can accurately predict sedation levels. The results obtained in this study may provide a useful reference for developing next generation EEG based sedation level prediction systems using advanced machine learning algorithms. Clinical trial registration: NCT02043938 and NCT03143972.


Assuntos
Eletroencefalografia , Propofol , Adulto , Algoritmos , Eletroencefalografia/métodos , Humanos , Aprendizado de Máquina , Dor , Remifentanil
12.
Anesth Pain Med (Seoul) ; 17(1): 44-51, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34784459

RESUMO

BACKGROUND: Differences in the effects of propofol and dexmedetomidine sedation on electroencephalogram patterns have been reported previously. However, the reliability of the Bispectral Index (BIS) value for assessing the sedation caused by dexmedetomidine remains debatable. The purpose of this study is to evaluate the correlation between the BIS value and the Modified Observer's Assessment of Alertness/Sedation (MOAA/S) scale in patients sedated with dexmedetomidine. METHODS: Forty-two patients (age range, 20-80 years) who were scheduled for elective surgery under spinal anesthesia were enrolled in this study. Spinal anesthesia was performed using 0.5% bupivacaine, which was followed by dexmedetomidine infusion (loading dose, 0.5-1 µg/kg for 10 min; maintenance dose, 0.3-0.6 µg/kg/h). The MOAA/S score was used to evaluate the level of sedation, and the Vital Recorder program was used to collect data (vital signs and BIS values). RESULTS: A total of 215082 MOAA/S scores and BIS data pairs were analyzed. The baseline variability of the BIS value was 7.024%, and the decrease in the BIS value was associated with a decrease in the MOAA/S score. The correlation coefficient and prediction probability between the two measurements were 0.566 (P < 0.0001) and 0.636, respectively. The mean ± standard deviation values of the BIS were 87.22 ± 7.06, 75.85 ± 9.81, and 68.29 ± 12.65 when the MOAA/S scores were 5, 3, and 1, respectively. Furthermore, the cut-off BIS values in the receiver operating characteristic analysis at MOAA/S scores of 5, 3, and 1 were 82, 79, and 73, respectively. CONCLUSION: The BIS values were significantly correlated with the MOAA/S scores. Thus, the BIS along with the clinical sedation scale might prove useful in assessing the hypnotic depth of a patient during sedation with dexmedetomidine.

13.
J Clin Med ; 10(24)2021 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-34945064

RESUMO

Postoperative delirium (POD) is a common perioperative complication. Although POD is preventable in up to 40% of patients, it is frequently overlooked. The objective of the survey is to determine the level of knowledge and clinical practices related to POD among anesthesiologists in different Asian countries. A questionnaire of 22 questions was designed by members of the Asian focus group for the study of POD, and it was sent to anesthesiologists in Singapore, Thailand, and South Korea from 1 April 2019 through 17 September 2019. In total, 531 anesthesiologists (Singapore: 224, Thailand: 124, Korea: 183) responded to the survey. Half the respondents estimated the incidence of POD to be 11-30% and believed that it typically occurs in the first 48 h after surgery. Among eight important postoperative complications, POD was ranked fifth. While 51.4% did not perform any test for POD, only 13.7% monitored the depth of anesthesia in all their patients. However, 83.8% preferred depth of anesthesia monitoring if they underwent surgery themselves. The results suggest that Asian anesthesiologists underestimate the incidence and relevance of POD. Because it increases perioperative mortality and morbidity, there is an urgent need to educate anesthesiologists regarding the recognition, prevention, detection, and management of POD.

14.
Paediatr Anaesth ; 31(10): 1031-1039, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34218499

RESUMO

The brain is considered as the major target organ of anesthetic agents. Despite that, a reliable means to monitor its function during anesthesia is lacking. Mid latency auditory evoked potentials are known to be sensitive to anesthetic agents and might therefore be a measure of hypnotic state in pediatric patients. This review investigates the available literature describing various aspects of mid latency auditory evoked potential monitoring in pediatric anesthesia.


Assuntos
Anestesia Geral , Anestésicos , Anestésicos/farmacologia , Criança , Potenciais Evocados Auditivos , Humanos
15.
Rev. bras. ter. intensiva ; 32(4): 535-541, out.-dez. 2020. tab, graf
Artigo em Inglês, Português | LILACS | ID: biblio-1156255

RESUMO

RESUMO Objetivo: Investigar a viabilidade do índice bispectral na avaliação do sono de pacientes criticamente enfermos lúcidos e a associação entre os parâmetros do sono aferidos por esse índice, pelo Questionário de Sono de Richards-Campbell e pelo ruído ambiental. Métodos: Estudo observacional transversal que avaliou indivíduos adultos criticamente enfermos com doenças de gravidades baixa ou moderada. Foram aferidos: volume e tempo total de sono, volume e tempo de sono profundo, volume e tempo de sono contínuo, latência para o início do sono e pressão sonora ambiental. A percepção subjetiva do sono foi registrada com o Questionário de Sono de Richards-Campbell nas manhãs subsequentes às noites de observação. Resultados: Os pacientes apresentaram tempo total de sono reduzido (234 minutos), predominância dos estágios superficiais e pouco sono profundo (1,7 minutos). Os volumes de sono total, profundo e contínuo foram 3.679, 9,4 e 3.143 índice bispectral versus minutos, respectivamente. A latência para o sono foi de 94 minutos. O escore médio do Questionário de Sono de Richards-Campbell foi 57,9. Foram observadas correlações de magnitudes fracas entre volume total, tempo total, volume contínuo e os domínios do Questionário de Sono de Richards-Campbell profundidade do sono, qualidade geral de sono e escore total; e correlações de magnitudes moderadas entre volume total, tempo total, volume contínuo e o domínio ocorrência de despertares. Conclusão: O índice bispectral é um instrumento com viabilidade limitada para monitorar o sono de pacientes lúcidos e com enfermidades de gravidades baixa e moderada na unidade de terapia intensiva, e pacientes que apresentaram maior volume, tempo total e volume de sono contínuo tiveram melhor percepção global do sono.


Abstract Objective: To investigate the viability of the bispectral index in the sleep evaluation of critically ill patients and to quantify the associations of sleep parameters measured by this index with the Richards-Campbell Sleep Questionnaire and environmental noise. Methods: This was a cross-sectional observational study that evaluated critically ill adults with diseases of low or moderate severity. The following were measured: total sleep volume and time, deep sleep volume and time, continuous sleep volume and time, sleep onset latency, and environmental sound pressure level. The subjective perception of sleep was evaluated with the Richards-Campbell Sleep Questionnaire the morning after each night of observation. Results: Patients had a low total sleep time (234 minutes), a predominance of superficial sleep stages, and little deep sleep (1.7 minutes). The total, deep, and continuous sleep volumes were 3,679, 9.4, and 3,143 (bispectral index units × minutes), respectively. The sleep latency was 94 minutes. The mean score of the Richards-Campbell Sleep Questionnaire was 57.9. Total sleep volume, total sleep time, and continuous sleep volume were weakly correlated with the Richards-Campbell Sleep Questionnaire depth of sleep domain score, overall sleep quality domain score, and total score. Total volume, total time, and continuous volume were moderately correlated with the occurrence of awakenings domain score. Conclusion: The bispectral index is an instrument with limited viability to monitor the sleep of lucid patients and patients with low to moderate disease severity in the intensive care unit. Patients with higher total sleep volume, total sleep time, and continuous sleep volume had better overall sleep perception.


Assuntos
Humanos , Sono , Unidades de Terapia Intensiva , Estudos Transversais , Inquéritos e Questionários , Estado Terminal
16.
An Pediatr (Engl Ed) ; 93(4): 251-256, 2020 Oct.
Artigo em Espanhol | MEDLINE | ID: mdl-32005596

RESUMO

INTRODUCTION: It has been suggested that neuromuscular blockade (NMB) affects the capacity of bispectral index (BIS) monitoring to measure consciousness in sedated children. Our aim was to analyse the impact of NMB on BIS values in critically ill children. METHODS: We conducted a prospective observational study of children monitored with a BIS system that received a continuous infusion of vecuronium. We analysed data on clinical, diagnostic and haemodynamic variables, sedatives, analgesics, muscle relaxants, and BIS parameters. We compared BIS parameters before the use of a muscle relaxant, during its administration, before its discontinuation and for the 24hours following the end of the infusion. RESULTS: The analysis included 35 patients (median age, 30 months). The most common diagnosis was heart disease (85%). The most frequent indication for initiation of NMB was low cardiac output (45%), followed by adaptation to mechanical ventilation (20%). Neuromuscular blockade did not produce a significant change in BIS values. We found a decrease was observed in electromyography values at 6hours (34.9 ± 9.4 vs. 31.2 ± 7; P=.008) and 12hours after initiation of NMB (34.9 ± 9.4 vs. 28.6 ± 4.8; P=.006). We observed a small significant increase in BIS after discontinuation of NMB (from 42.7 ± 11 to 48.4 ± 14.5, P=.001), and 6 and 12hours later (51.3 ± 16.6; P=.015). There were no differences in the doses of sedatives or analgesics except for fentanyl, of which the dose was lowered after discontinuation of vecuronium. CONCLUSION: Continuous NMB produces small changes on BIS values that are not clinically significant and therefore does not interfere with BIS consciousness monitoring in critically ill children.


Assuntos
Monitores de Consciência , Estado de Consciência/efeitos dos fármacos , Estado Terminal , Bloqueio Neuromuscular/efeitos adversos , Bloqueadores Neuromusculares/efeitos adversos , Monitorização Neurofisiológica/métodos , Adolescente , Criança , Pré-Escolar , Eletroencefalografia , Eletromiografia , Feminino , Humanos , Lactente , Masculino , Estudos Prospectivos
17.
An Pediatr (Engl Ed) ; 93(4): 251-256, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34092338

RESUMO

INTRODUCTION: It has been suggested that neuromuscular blockade (NMB) affects the capacity of bispectral index (BIS) monitoring to measure consciousness in sedated children. Our aim was to analyse the impact of NMB on BIS values in critically ill children. METHODS: We conducted a prospective observational study of children monitored with a BIS system that received a continuous infusion of vecuronium. We analysed data on clinical, diagnostic and haemodynamic variables, sedatives, analgesics, muscle relaxants, and BIS parameters. We compared BIS parameters before the use of a muscle relaxant, during its administration, before its discontinuation and for the 24h following the end of the infusion. RESULTS: The analysis included 35 patients (median age, 30 months). The most common diagnosis was heart disease (85%). The most frequent indication for initiation of NMB was low cardiac output (45%), followed by adaptation to mechanical ventilation (20%). Neuromuscular blockade did not produce a significant change in BIS values. We found a decrease was observed in electromyography (EMG) values at 6h (34.9±9.4 vs 31.2±7; P=.008) and 12h after initiation of NMB (34.9±9.4 vs 28.6±4.8; P =.006). We observed a small significant increase in BIS after discontinuation of NMB (from 42.7±11 to 48.4±14.5, P=.001), and 6 and 12h later (51.3±16.6; P=.015). There were no differences in the doses of sedatives or analgesics except for fentanyl, of which the dose was lowered after discontinuation of vecuronium. CONCLUSION: Continuous NMB produces small changes on BIS values that are not clinically significant and therefore does not interfere with BIS consciousness monitoring in critically ill children.


Assuntos
Monitores de Consciência , Estado Terminal , Bloqueio Neuromuscular , Pré-Escolar , Eletromiografia , Humanos , Brometo de Vecurônio
18.
J Int Med Res ; 48(4): 300060519893165, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31875756

RESUMO

OBJECTIVE: The bispectral index (BIS) has been used to monitor sedation during spinal anesthesia. We evaluated the correlation between BIS and the Observer's Assessment of Alertness/Sedation Scale (OAA/S) in patients sedated with dexmedetomidine, propofol, or midazolam. METHODS: This prospective, randomized study included 46 patients scheduled for knee arthroplasty under spinal anesthesia with sedation. The patients were randomized to receive sedation with dexmedetomidine (n = 15), propofol (n = 15), or midazolam (n = 16). Correlation between BIS and OAA/S was assessed during sedation in the three groups. RESULTS: A linear correlation was observed between BIS and OAA/S, and there was no significant difference in BIS score between the groups during mild to moderate sedation status (OAA/S 3-5). During deep sedation (OAA/S 1-2), the BIS score in the midazolam group was significantly higher than that in the propofol and dexmedetomidine groups (74.4 ± 11.9 vs 67.7 ± 9.5 vs 62.6 ± 12.2). CONCLUSIONS: BIS values differed at the same level of sedation between different sedative agents. Objective sedation scores should therefore be used in combination with BIS values for the assessment of sedation levels during spinal anesthesia.


Assuntos
Raquianestesia , Propofol , Sedação Consciente , Eletroencefalografia , Humanos , Hipnóticos e Sedativos , Midazolam
19.
Yeungnam Univ J Med ; 36(1): 50-53, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-31620612

RESUMO

Awareness during general anesthesia occurs in approximately 0.1-0.2% of cases; nevertheless, particular attention is required because it can lead to critical complications including insomnia, depression, anxiety, and post-traumatic stress disorder. To prevent these complications, bispectral index (BIS) and end-tidal anesthetic gas (ETAG) concentration monitoring are commonly used to examine patient consciousness during surgery. In the present case, an 80-year-old man was scheduled for total gastrectomy. Anesthesia was maintained using desflurane 4.0-5.0% vol, oxygen, and nitrous oxide. The authors simultaneously monitored BIS, which was maintained between 37 and 43, and ETAG, which was maintained between 0.9 and 1.2 minimum alveolar concentration (MAC). After the operation, however, the authors were surprised to learn that the patient complained of awareness during anesthesia. Although BIS and ETAG concentration monitoring are useful in preventing awareness during anesthesia, they cannot be completely trusted. Even though BIS was maintained at approximately 40 and ETAG at 0.7-1.3 MAC, awareness during anesthesia occurred.

20.
Rev. colomb. anestesiol ; 47(3): 194-197, July-Sept. 2019. graf
Artigo em Inglês | LILACS, COLNAL | ID: biblio-1013889

RESUMO

Abstract We present the case of an adult with an extensive left frontal meningioma. He was scheduled for resection by craniotomy. During the surgery we used the density spectral array (DSA) and asymmetry obtained from Bispectral Index VISTA Monitoring System Bilateral. We observed a power increase in low frequency (0.1-1 Hz) and alpha bands (8-12 Hz) in the left hemisphere, where the meningioma was located. In this case, DSA was useful during and after the surgery because it provided information about the hemisphere with maximum brain activity and its subsequent normalization, which may reflect the effectiveness of the surgery.


Resumen Presentamos el caso de un paciente adulto con diagnóstico de un meningioma extenso a nivel frontal izquierdo, que fue programado para exéresis mediante craneotomía. Durante la cirugía se utilizó la Matriz de Densidad Espectral (MDE) y la asimetría obtenida del Sistema de Monitorización VISTATM del Índice Biespectral Bilateral (BVMS). Se observó un aumento de potencia en las bandas de baja frecuencia (0.1-1Hz) y en las bandas alfa (812 Hz) del hemisferio cerebral izquierdo, donde se encontraba el meningioma. En este caso la MDE demostró su utilidad durante y después de la cirugía, al proporcionar información sobre el hemisferio con registro de máxima actividad cerebral y su posterior normalización, reflejando así la efectividad de la cirugía.


Assuntos
Humanos , Masculino , Idoso de 80 Anos ou mais , Cuidados Pós-Operatórios , Craniotomia , Meningioma , Procedimentos Neurocirúrgicos , Eletroencefalografia , Monitores de Consciência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...