Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
PNAS Nexus ; 3(3): pgae085, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38476666

RESUMO

Legionnaires' disease (LD) is a severe form of pneumonia (∼10-25% fatality rate) caused by inhalation of aerosols containing Legionella, a pathogenic gram-negative bacteria. These bacteria can grow, spread, and aerosolize through building water systems. A recent dramatic increase in LD incidence has been observed globally, with a 9-fold increase in the United States from 2000 to 2018, and with disproportionately higher burden for socioeconomically vulnerable subgroups. Despite the focus of decades of research since the infamous 1976 outbreak, substantial knowledge gaps remain with regard to source of exposure and the reason(s) for the dramatic increase in LD incidence. Here, we rule out factors indicated in literature to contribute to its long-term increases and identify a hitherto unexplored explanatory factor. We also provide an epidemiological demonstration that the occurrence of LD is linked with exposure to cooling towers (CTs). Our results suggest that declining sulfur dioxide air pollution, which has many well-established health benefits, results in reduced acidity of aerosols emitted from CTs, which may prolong the survival duration of Legionella in contaminated CT droplets and contribute to the increase in LD incidence. Mechanistically associating decreasing aerosol acidity with this respiratory disease has implications for better understanding its transmission, predicting future risks, and informed design of preventive and interventional strategies that consider the complex impacts of continued sulfur dioxide changes.

2.
Microorganisms ; 11(3)2023 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-36985310

RESUMO

Free-living nematodes harbor and disseminate various soil-borne bacterial pathogens. Whether they function as vectors or environmental reservoirs for the aquatic L. pneumophila, the causative agent of Legionnaires' disease, is unknown. A survey screening of biofilms of natural (swimming lakes) and technical (cooling towers) water habitats in Germany revealed that nematodes can act as potential reservoirs, vectors or grazers of L. pneumophila in cooling towers. Consequently, the nematode species Plectus similis and L. pneumophila were isolated from the same cooling tower biofilm and taken into a monoxenic culture. Using pharyngeal pumping assays, potential feeding relationships between P. similis and different L. pneumophila strains and mutants were examined and compared with Plectus sp., a species isolated from a L. pneumophila-positive thermal source biofilm. The assays showed that bacterial suspensions and supernatants of the L. pneumophila cooling tower isolate KV02 decreased pumping rate and feeding activity in nematodes. However, assays investigating the hypothesized negative impact of Legionella's major secretory protein ProA on pumping rate revealed opposite effects on nematodes, which points to a species-specific response to ProA. To extend the food chain by a further trophic level, Acanthamoebae castellanii infected with L. pneumphila KV02 were offered to nematodes. The pumping rates of P. similis increased when fed with L. pneumophila-infected A. castellanii, while Plectus sp. pumping rates were similar when fed either infected or non-infected A. castellanii. This study revealed that cooling towers are the main water bodies where L. pneumophila and free-living nematodes coexist and is the first step in elucidating the trophic links between coexisting taxa from that habitat. Investigating the Legionella-nematode-amoebae interactions underlined the importance of amoebae as reservoirs and transmission vehicles of the pathogen for nematode predators.

3.
Pathogens ; 12(3)2023 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-36986388

RESUMO

Legionella pneumophila (Lp) colonizes aquatic environments and is a potential pathogen to humans, causing outbreaks of Legionnaire's disease. It is mainly associated with contaminated cooling towers (CTs). Several regulations, including Spanish legislation (Sl), have introduced the analysis of heterotrophic plate count (HPC) bacteria and Legionella spp. (Lsp) in management plans to prevent and control Legionella outbreaks from CTs. The 2003 Sl for CTs (RD 865/2003) considered that concentrations of HPC bacteria ≤10,000 cfu/mL and of Lsp ≤100 cfu/L are safe; therefore, no action is required, whereas management actions should be implemented above these standards. We have investigated to what extent the proposed standard for HPC bacteria is useful to predict the presence of Lsp in cooling waters. For this, we analyzed Lsp and HPC concentrations, water temperature, and the levels of chlorine in 1376 water samples from 17 CTs. The results showed that in the 1138 water samples negative for Legionella spp. (LN), the HPC geometric mean was significantly lower (83 cfu/mL, p < 0.05) than in the positive Lsp. samples (135 cfu/mL). Of the 238 (17.3%) LP samples, 88.4% (210/238) were associated with values of HPC ≤10,000 cfu/mL and most of them showed HPC concentrations ≤100 (53.7%). In addition, a relatively low percentage of LP (28/238, 11.6%) samples were associated with HPC bacteria concentrations >10,000 cfu/mL, indicating that this standard does not predict the colonization risk for Legionella in the CTs studied. The present study has demonstrated that a threshold concentration ≤100 cfu/mL of HPC bacteria could better predict the higher concentration of Legionella in CTs, which will aid in preventing possible outbreaks.

4.
Environ Technol ; : 1-10, 2022 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-36282279

RESUMO

Contaminants from cooling water waste (CWW) generated by industries represent an environmental hazard if discharged into aquatic bodies and soil without treatment. Most treatment strategies are energy-demanding and costly; hence, low-cost and sustainable treatment alternative technologies are needed. The present study proposed cyanobacteria culture as a low-cost biological method to treat cooling water waste (CWW) while simultaneously producing carbohydrates. For this purpose, CWW from a cooling tower was evaluated in different dilutions with domestic wastewater (DW) (DW25% -CWW75%, DW50% -CWW50%, DW25% -CWW75%, DW100%, and CWW100%) (v/v). The CWW provided a high content of inorganic carbon and low content of N and P, which resulted in a high C/N ratio promoting a fast carbohydrate accumulation but low biomass production. In contrast, cultures with higher DW concentrations achieved similar results in 14 days. The best results were obtained with DW25% -CWW75%, achieving up to 52 ± 18% carbohydrate content on day 8, with the highest biomass concentration of 1.7 ± 0.12 g L-1 on day 14. This culture removed >94% of TAN, N-NO3- and P-PO43-, and 84 ± 10.82% of COD. This strategy could be a promising approach to treating CWW and DW from the same industry and producing value-added products and bioenergy.

5.
Water Res ; 216: 118328, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35364354

RESUMO

Legionella pneumophila is a natural inhabitant of water systems. From there, it can be transmitted to humans by aerosolization resulting in severe pneumonia. Most large outbreaks are caused by cooling towers colonized with L. pneumophila. The resident microbiota of the cooling tower is a key determinant for the colonization and growth of L. pneumophila. In our preceding study, the genus Pseudomonas correlated negatively with the presence of L. pneumophila in cooling towers, but it was not clear which species was responsible. Therefore, we identified the Pseudomonas species inhabiting 14 cooling towers using a Pseudomonas-specific 16S rRNA amplicon sequencing strategy. We found that cooling towers that are free of L. pneumophila contained a high relative abundance of members from the Pseudomonas alcaliphila/oleovorans phylogenetic cluster. P. alcaliphila JCM 10630 inhibited the growth of L. pneumophila on agar plates. Analysis of the P. alcaliphila genome revealed the presence of a gene cluster predicted to produce toxoflavin. L. pneumophila growth was inhibited by pure toxoflavin and by extracts from P. alcaliphila culture found to contain toxoflavin by liquid chromatography coupled with mass spectrometry. In addition, toxoflavin inhibits the growth of Vermameoba vermiformis, a host cell of L. pneumophila. Our study indicates that P. alcaliphila may be important to restrict growth of L. pneumophila in water systems through the production of toxoflavin. A sufficiently high concentration of toxoflavin is likely not achieved in the bulk water but might have a local inhibitory effect such as near or in biofilms.


Assuntos
Legionella pneumophila , Legionella , Humanos , Legionella/genética , Legionella pneumophila/genética , Filogenia , Pseudomonas/genética , Pirimidinonas , RNA Ribossômico 16S/genética , Triazinas , Água , Microbiologia da Água
6.
Microorganisms ; 10(2)2022 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-35208847

RESUMO

Legionella pneumophila is the causative agent of Legionnaires' disease, a severe pneumonia. Cooling towers are a major source of large outbreaks of the disease. The growth of L. pneumophila in these habitats is influenced by the resident microbiota. Consequently, the aim of this study was to isolate and characterize bacterial species from cooling towers capable of inhibiting several strains of L. pneumophila and one strain of L. quinlivanii. Two cooling towers were sampled to isolate inhibiting bacterial species. Seven inhibitory isolates were isolated, through serial dilution plating and streaking on agar plates, belonging to seven distinct species. The genomes of these isolates were sequenced to identify potential genetic elements that could explain the inhibitory effect. The results showed that the bacterial isolates were taxonomically diverse and that one of the isolates may be a novel species. Genome analysis showed a high diversity of antimicrobial gene products identified in the genomes of the bacterial isolates. Finally, testing different strains of Legionella demonstrated varying degrees of susceptibility to the antimicrobial activity of the antagonistic species. This may be due to genetic variability between the Legionella strains. The results demonstrate that though cooling towers are breeding grounds for L. pneumophila, the bacteria must contend with various antagonistic species. Potentially, these species could be used to create an inhospitable environment for L. pneumophila, and thus decrease the probability of outbreaks occurring.

7.
Pathogens ; 10(11)2021 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-34832563

RESUMO

Pathogenic Legionella species grow optimally inside free-living amoebae to concentrations that increase risks to those who are exposed. The aim of this study was to screen a complete drinking water system and cooling towers for the occurrence of Acanthamoeba spp. and Naegleria fowleri and their cooccurrence with Legionella pneumophila, Legionella anisa, Legionella micdadei, Legionella bozemanii, and Legionella longbeachae. A total of 42 large-volume water samples, including 12 from the reservoir (water source), 24 from two buildings (influents to the buildings and exposure sites (taps)), and six cooling towers were collected and analyzed using droplet digital PCR (ddPCR). N. fowleri cooccurred with L. micdadei in 76 (32/42) of the water samples. In the building water system, the concentrations of N. fowleri and L. micdadei ranged from 1.5 to 1.6 Log10 gene copies (GC)/100 mL, but the concentrations of species increased in the cooling towers. The data obtained in this study illustrate the ecology of pathogenic Legionella species in taps and cooling towers. Investigating Legionella's ecology in drinking and industrial waters will hopefully lead to better control of these pathogenic species in drinking water supply systems and cooling towers.

8.
Environ Monit Assess ; 193(10): 635, 2021 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-34491444

RESUMO

The paper presents measurement data concerning the degree of acidification of precipitation collected during a 6-month measurement campaign carried out in an immediate vicinity of a power plant, where the cooling tower was used for discharging flue gases as a product of coal combustion. As reference, data obtained from parallel measurements carried out at a monitoring station considered as city background station were used. High acidity of precipitation was anticipated due to reactions of acid gases contained in the combustion gases with water, which already occur inside the cooling tower. The results have not confirmed this assumption. The pH value of the precipitation samples was significantly higher than the pH of rainwater at the background station located 18 km away from the power plant.


Assuntos
Poluentes Atmosféricos , Poluentes Atmosféricos/análise , Carvão Mineral/análise , Monitoramento Ambiental , Gases , Centrais Elétricas
9.
Microorganisms ; 9(3)2021 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-33802700

RESUMO

Most literature to date on the use of rapid Legionella tests have compared different sampling and analytical techniques, with few studies on real-world experiences using such methods. Rapid tests offer a significantly shorter feedback loop on the effectiveness of the controls. This study involved a complex of five factories, three of which had a history of Legionella contamination in their cooling water distribution system. Multiple sampling locations were utilised to take monthly water samples over 39 months to analyse for Legionella by both culture and quantitative polymerase chain reaction (qPCR). Routine monitoring gave no positive Legionella results by culture (n = 330); however, samples were frequently (68%) positive by qPCR for Legionella spp. (n = 1564). Legionella spp. qPCR assay was thus found to be a good indicator of cooling tower system health and suitable as a routine monitoring tool. An in-house qPCR limit of 5000 genomic units (GU)/L Legionella spp. was established to trigger investigation and remedial action. This approach facilitated swift remedial action to prevent Legionella proliferation to levels that may represent a public health risk. Cooling tower operators may have to set their own action levels for their own systems; however, in this study, 5000 GU/L was deemed appropriate and pragmatic.

10.
Water Res ; 196: 117013, 2021 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-33813251

RESUMO

The present study analyzes at the national level, the presence of circulating Legionella in the artificial aquatic systems of different facilities of all of them state-owned centers throughout Spain for 12 months. 1754 water samples from various state-owned centers were collected from January to December 2014. Samples were collected from the cooling towers and evaporative condensers (CTC), and water distribution networks such as domestic hot water (DHW), cold water for human consumption (CW), sprinkler irrigation systems (SIS), fire sprinkler systems (FSS), and water from decorative fountains (DF). All these facilities are considered, according to current regulations, as potential amplifying systems for bacteria and possible sources of infection by the generation of droplets and aerosols. The isolation and counting of Legionella in water samples was carried out using microbiological culture following the international normative UNE-EN-ISO 11,731:2007 (ISO 11,731:1998) and UNE-EN ISO 8199:2008 (ISO 8199:2005).The quantification of Legionella colonization, the annual distribution, and the geographical distribution of the Legionella isolates recovered in the water were analyzed. Besides, molecular techniques were used for the characterization of the Legionella non-pneumophila isolates. Legionella was recovered from 15.79% of the analyzed water samples. High colonization was more frequently detected in water samples from CTC, DHW, CW, and DF. Regarding the geographic distribution, positive samples of Legionella were obtained in 14 of the 18 Spanish locations analyzed. Legionella non-pneumophila was the most prevalent and was isolated from water samples from 13 different geographical locations (72%). Legionella anisa and Legionella jordanis were the most frequently non-pneumophila species isolated. Legionella donaldsonii was isolated for the first time in the water distribution networks in Spain. Legionella pneumophila sg 2-14 was detected in 13 locations and Legionella pneumophila sg 1 in 11 locations. Therefore, our study concludes that the presence of Legionella pneumophila and Legionella non-pneumophila species in these systems can be a potential threat to public health and should be examined thoroughly with complementary techniques, such as molecular techniques as a screen for routine diagnosis.


Assuntos
Legionella pneumophila , Legionella , Humanos , Espanha , Água , Microbiologia da Água , Abastecimento de Água
11.
Biosensors (Basel) ; 11(2)2021 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-33513950

RESUMO

The detection of water contamination with Legionella pneumophila is of critical importance to manufacturers of water processing equipment and public health entities dealing with water networks and distribution systems. Detection methods based on polymerase chain reaction or biosensor technologies require preconcentration steps to achieve attractive sensitivity levels. Preconcentration must also be included in protocols of automated collection of water samples by systems designed for quasi-continuous monitoring of remotely located water reservoirs for the presence of L. pneumophila. We designed and characterized a water sampling module for filtration and backwashing intended for analysis of low-to-medium contaminated water, typically with L. pneumophila bacteria not exceeding 50 colony-forming units per milliliter. The concentration factors of 10× and 21× were achieved with 0.22 and 0.45 µm filters, respectively, for samples of bacteria prepared in clean saline solutions. However, a 5× concentration factor was achieved with 0.45 µm filters for a heavily contaminated or turbid water typical of some industrial water samples.


Assuntos
Monitoramento Ambiental/métodos , Legionella pneumophila/isolamento & purificação , Microbiologia da Água , Filtração , Água , Poluição da Água/estatística & dados numéricos
12.
Chemosphere ; 265: 129075, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33288282

RESUMO

In this review article, illustrating the impact and fundamental stuff of microbially influenced corrosion (MIC) along with mechanism, maintenance of materials, human life, wellbeing and inhibitors for cooling towers. Corrosion is a natural mechanism of oxidation and reduction of metal ions by chemical and electrochemical processes and microorganism accumulation. MIC occurs through the aggregation of microbes which can be secreting the extra polymeric substances (EPS) that oxidation of the metal surface. According to the reviews, in the cooling water system, the corrosion begins in the anode charge because its oxidation reaction quickly takes place on the metal surface than the cathode charge. Annihilate the corrosion process needs certain helper substances such as chemical or green compounds, called inhibitors. Corrosion inhibitors typically adopt the adsorption mechanism due to the presence of organic hetero atoms. Chemical and green inhibitors are used to prevent corrosion processes and since ancient times, vast quantities of chemical inhibitors have been used in industry due to their effectiveness and consistency. But still, the chemical inhibitors are more toxic to humans and the environment. Instead of chemical inhibitors, green inhibitors (natural products like plant leaves, flowers, stem, buds, roots and sea algae) are developed and used in industries. Generally, green inhibitors contain natural compounds, high inhibition efficiency, economic, eco- and human-friendly, and strong potential features against corrosion. Thus, a lot of research is ongoing to discover the green inhibitors in various parts of plants and seaweeds.


Assuntos
Metais , Águas Residuárias , Corrosão , Humanos , Oxirredução
13.
Pathogens ; 9(2)2020 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-32041369

RESUMO

Legionella pneumophila is a facultative intracellular pathogen found in aquatic environments as planktonic cells within biofilms and as intracellular parasites of free-living amoebae such as Acanthamoeba castellanii. This pathogen bypasses the elimination mechanism to replicate within amoebae; however, not all amoeba species support the growth of L. pneumophila. Willaertia magna C2c Maky, a non-pathogenic amoeba, was previously demonstrated to possess the ability to eliminate the L. pneumophila strain Paris. Here, we study the intracellular behaviour of three L. pneumophila strains (Paris, Philadelphia, and Lens) within W. magna C2c Maky and compare this strain to A. castellanii and W. magna Z503, which are used as controls. We observe the intracellular growth of strain Lens within W. magna Z503 and A. castellanii at 22 °C and 37 °C. Strain Paris grows within A. castellanii at any temperature, while it only grows at 22 °C within W. magna Z503. Strain Philadelphia proliferates only within A. castellanii at 37 °C. Within W. magna C2c Maky, none of the three legionella strains exhibit intracellular growth. Additionally, the ability of W. magna C2c Maky to decrease the number of internalized L. pneumophila is confirmed. These results support the idea that W. magna C2c Maky possesses unique behaviour in regard to L. pneumophila strains.

14.
Sci Total Environ ; 712: 136131, 2020 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-31931228

RESUMO

Legionella pneumophila is a waterborne bacterium known for causing Legionnaires' Disease, a severe pneumonia. Cooling towers are a major source of outbreaks, since they provide ideal conditions for L. pneumophila growth and produce aerosols. In such systems, L. pneumophila typically grow inside protozoan hosts. Several abiotic factors such as water temperature, pipe material and disinfection regime affect the colonization of cooling towers by L. pneumophila. The local physical and biological factors promoting the growth of L. pneumophila in water systems and its spatial distribution are not well understood. Therefore, we built a lab-scale cooling tower to study the dynamics of L. pneumophila colonization in relationship to the resident microbiota and spatial distribution. The pilot was filled with water from an operating cooling tower harboring low levels of L. pneumophila. It was seeded with Vermamoeba vermiformis, a natural host of L. pneumophila, and then inoculated with L. pneumophila. After 92 days of operation, the pilot was disassembled, the water was collected, and biofilm was extracted from the pipes. The microbiome was studied using 16S rRNA and 18S rRNA genes amplicon sequencing. The communities of the water and of the biofilm were highly dissimilar. The relative abundance of Legionella in water samples reached up to 11% whereas abundance in the biofilm was extremely low (≤0.5%). In contrast, the host cells were mainly present in the biofilm. This suggests that L. pneumophila grows in host cells associated with biofilm and is then released back into the water following host cell lysis. In addition, water temperature shaped the bacterial and eukaryotic community of the biofilm, indicating that different parts of the systems may have different effects on Legionella growth.


Assuntos
Legionella pneumophila , Biofilmes , RNA Ribossômico 16S , Temperatura , Microbiologia da Água
15.
Water Res ; 169: 115252, 2020 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-31726393

RESUMO

Legionnaires' disease (LD) is a severe pneumonia caused by several species of the genus Legionella, most frequently by Legionella pneumophila. Cooling towers are the most common source for large community-associated outbreaks. Colonization, survival, and proliferation of L. pneumophila in cooling towers are necessary for outbreaks to occur. These steps are affected by the chemical and physical parameters of the cooling tower environment. We hypothesize that the bacterial community residing in the cooling tower could also affect the presence of L. pneumophila. A 16S rRNA gene targeted amplicon sequencing approach was used to study the bacterial community of cooling towers and its relationship with the Legionella spp. and L. pneumophila communities. The results indicated that the water source shaped the bacterial community of cooling towers. Several taxa were enriched and positively correlated with Legionella spp. and L. pneumophila. In contrast, Pseudomonas showed a strong negative correlation with Legionella spp. and several other genera. Most importantly, continuous chlorine application reduced microbial diversity and promoted the presence of Pseudomonas creating a non-permissive environment for Legionella spp. This suggests that disinfection strategies as well as the resident microbial population influences the ability of Legionella spp. to colonize cooling towers.


Assuntos
Legionella pneumophila , Legionella , Doença dos Legionários , Cloro , Humanos , Pseudomonas , RNA Ribossômico 16S , Microbiologia da Água
16.
J Environ Manage ; 236: 561-570, 2019 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-30771675

RESUMO

Wastewater and power utilities in the United States have an enormous opportunity to collaborate on the mutually beneficial uses of reclaimed water. Despite close proximity to wastewater facilities, only a limited number of power plants are currently using municipal reclaimed water for cooling tower and boiler applications. Through a review of the literature, this document aims at creating a more perspicuous understanding of the reuse of reclaimed water for power plant applications, particularly as pertains to those associated with cooling towers and boilers, by highlighting the drivers of current implementation, regulatory issues and treatment goals, and available treatment technologies. Through an in-depth analysis of case studies, the review also highlights key examples of reclaimed water reuse projects at power utilities together with the related benefits and challenges.


Assuntos
Purificação da Água , Água , Centrais Elétricas , Eliminação de Resíduos Líquidos , Águas Residuárias , Abastecimento de Água
17.
Water Res ; 134: 261-279, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-29428779

RESUMO

The use of reclaimed water brings new challenges for the water industry in terms of maintaining water quality while increasing sustainability. Increased attention has been devoted to opportunistic pathogens, especially Legionella pneumophila, due to its growing importance as a portion of the waterborne disease burden in the United States. Infection occurs when a person inhales a mist containing Legionella bacteria. The top three uses for reclaimed water (cooling towers, spray irrigation, and toilet flushing) that generate aerosols were evaluated for Legionella health risks in reclaimed water using quantitative microbial risk assessment (QMRA). Risks are compared using data from nineteen United States reclaimed water utilities measured with culture-based methods, quantitative PCR (qPCR), and ethidium-monoazide-qPCR. Median toilet flushing annual infection risks exceeded 10-4 considering multiple toilet types, while median clinical severity infection risks did not exceed this value. Sprinkler and cooling tower risks varied depending on meteorological conditions and operational characteristics such as drift eliminator performance. However, the greatest differences between risk scenarios were due to 1) the dose response model used (infection or clinical severity infection) 2) population at risk considered (residential or occupational) and 3) differences in laboratory analytical method. Theoretical setback distances necessary to achieve a median annual infection risk level of 10-4 are proposed for spray irrigation and cooling towers. In both cooling tower and sprinkler cases, Legionella infection risks were non-trivial at potentially large setback distances, and indicate other simultaneous management practices could be needed to manage risks. The sensitivity analysis indicated that the most influential factors for variability in risks were the concentration of Legionella and aerosol partitioning and/or efficiency across all models, highlighting the importance of strategies to manage Legionella occurrence in reclaimed water.


Assuntos
Aerossóis/análise , Legionella pneumophila/isolamento & purificação , Reciclagem , Microbiologia da Água , Irrigação Agrícola , Monitoramento Ambiental , Humanos , Legionella pneumophila/genética , Legionelose , Reação em Cadeia da Polimerase em Tempo Real , Medição de Risco , Banheiros , Água
18.
Environ Sci Pollut Res Int ; 25(6): 5412-5420, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29209978

RESUMO

Silver nanoparticle-aided enhancement in the anti-corrosion potential and stability of plant extract as ecologically benign alternative for microbially induced corrosion treatment is demonstrated. Bioengineered silver nanoparticles (AgNPs) surface functionalized with plant extract material (proteinacious) was generated in vitro in a test tube by treating ionic AgNO3 with the leaf extract of Azadirachta indica that acted as dual reducing as well as stabilizing agent. Purity and crystallinity of the AgNPs, along with physical and surface characterizations, were evaluated by performing transmission electron microscopy, Fourier transform infrared spectroscopy, energy dispersive x-ray spectra, single-area electron diffractions, zeta potential, and dynamic light scattering measurements. Anti-corrosion studies against mild steel (MS1010) by corrosion-inducive bacterium, Bacillus thuringiensis EN2 isolated from cooling towers, were evaluated by performing electrochemical impedance spectroscopy (EIS), weight loss analysis, and surface analysis by infrared spectroscopy. Our studies revealed that AgNPs profoundly inhibited the biofilm on MS1010 surface and reduced the corrosion rates with the CR of 0.5 mm/y and an inhibition efficiency of 77% when compared to plant extract alone with a CR of 2.2 mm/y and an inhibition efficiency of 52%. Further surface analysis by infrared spectra revealed that AgNPs formed a protective layer of self-assembled film on the surface of MS1010. Additionally, EIS and surface analysis revealed that the AgNPs have inhibited the bacterial biofilm and reduced the pit on MS1010. This is the first report disclosing the application of bioengineered AgNP formulations as potent anti-corrosive inhibitor upon forming a protective layer over mild steel in cooling water towers. Graphical Abstract ᅟ.


Assuntos
Antibacterianos/química , Bioengenharia/métodos , Nanopartículas Metálicas/química , Compostos de Prata/química , Aço/química , Antibacterianos/síntese química , Antibacterianos/farmacologia , Azadirachta/química , Bacillus thuringiensis/efeitos dos fármacos , Bacillus thuringiensis/fisiologia , Biofilmes/efeitos dos fármacos , Biofilmes/crescimento & desenvolvimento , Corrosão , Nanopartículas Metálicas/ultraestrutura , Extratos Vegetais/química , Extratos Vegetais/farmacologia
19.
Saudi Pharm J ; 25(7): 999-1004, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29158706

RESUMO

This study aimed to investigate for the first time the in vitro antibiofilm effectiveness of two chloramphenicol liposome formulations against biofilms of potentially pathogenic bacteria associated to corrosion isolated from the water of cooling towers from a Brazilian industry. Antibiofilm assays with liposomes were performed in 96-wells microtiter plates, and data was compared to free chloramphenicol treatment. Chloramphenicol-loaded liposomes were successfully produced using the dehydration-rehydration method, with vesicle diameters of 131 nm (100 nm membrane extrusion) and 182 nm (200 nm membrane extrusion) assessed by dynamic light scattering. The liposomes obtained by 100 nm membrane extrusion were more effective than 200 nm membrane extrusion vesicles against the biofilms after overnight exposure, and the free drug had no antibiofilm effect. Our study open doors for more investigations on liposome entrapment of antimicrobial compounds such as biocides of industrial use, for controlling biofilm formation in aquatic environments.

20.
Emerg Infect Dis ; 23(11): 1784-1791, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-29047425

RESUMO

During the summer of 2015, New York, New York, USA, had one of the largest and deadliest outbreaks of Legionnaires' disease in the history of the United States. A total of 138 cases and 16 deaths were linked to a single cooling tower in the South Bronx. Analysis of environmental samples and clinical isolates showed that sporadic cases of legionellosis before, during, and after the outbreak could be traced to a slowly evolving, single-ancestor strain. Detection of an ostensibly virulent Legionella strain endemic to the Bronx community suggests potential risk for future cases of legionellosis in the area. The genetic homogeneity of the Legionella population in this area might complicate investigations and interpretations of future outbreaks of Legionnaires' disease.


Assuntos
Surtos de Doenças , Legionella pneumophila/isolamento & purificação , Doença dos Legionários/epidemiologia , Doença dos Legionários/microbiologia , Abastecimento de Água , DNA Bacteriano , Microbiologia Ambiental , Genoma Bacteriano , Humanos , Legionella pneumophila/classificação , Legionella pneumophila/patogenicidade , New York/epidemiologia , Reação em Cadeia da Polimerase em Tempo Real , Sequenciamento Completo do Genoma
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...