Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 240
Filtrar
1.
J Cardiothorac Surg ; 19(1): 284, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38730503

RESUMO

INTRODUCTION: Post liver transplantation (LT) patients endure high morbidity rate of multi-organ ischemic symptoms following reperfusion. We hypothesize that enhanced external counterpulsation (EECP) as a typical non-invasive assisted circulation procedure, which can efficiently inhibit the relative ischemic symptoms via the systemic improvement of hemodynamics. CASE PRESENTATION: A 51-year-old male patient, 76 kg, 172 cm, received orthotopic LT surgery for viral hepatitis B induced acute-on-chronic liver failure hepatic failure. His medical records revealed ischemic symptoms in multi-organ at the time of hospital discharge, including headache, refractory insomnia, abdominal paralysis, and lower limb pain. The EECP treatment was introduced for assisted rehabilitation and to improve the postoperative quality of life. Doppler Ultrasound examination showed significant augmentation of blood flow volume in the carotid arteries, the hepatic artery, the portal vein and the femoral artery during EECP intervention. A standard 35-hour EECP treatment led to significant improvement in quality of life, e.g. sleep quality and walking ability. CONCLUSION: We report a case of multi-organ ischemic symptoms in a post LT patient. EECP treatment can significantly improve the quality of life via the systematic promotion of hemodynamics.


Assuntos
Contrapulsação , Hemodinâmica , Transplante de Fígado , Humanos , Masculino , Pessoa de Meia-Idade , Contrapulsação/métodos , Hemodinâmica/fisiologia , Complicações Pós-Operatórias/terapia , Qualidade de Vida , Isquemia/cirurgia , Isquemia/fisiopatologia
2.
Comput Methods Programs Biomed ; 250: 108191, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38677079

RESUMO

BACKGROUND AND OBJECTIVE: Enhanced external counterpulsation (EECP) is a mechanically assisted circulation technique widely used in the rehabilitation and management of ischemic cardiovascular diseases. It contributes to cardiovascular functions by regulating the afterload of ventricle to improve hemodynamic effects, including increased diastolic blood pressure at aortic root, increased cardiac output and enhanced blood perfusion to multiple organs including coronary circulation. However, the effects of EECP on the coupling of the ventricle and the arterial system, termed ventricular-arterial coupling (VAC), remain elusive. We aimed to investigate the acute effect of EECP on the dynamic interaction between the left ventricle and its afterload of the arterial system from the perspective of ventricular output work. METHODS: A neural network assisted optimization algorithm was proposed to identify the ordinary differential equation (ODE) relation between aortic root blood pressure and flow rate. Based on the optimized order of ODE, a lumped parameter model (LPM) under EECP was developed taking into consideration of the simultaneous action of cardiac and EECP pressure sources. The ventricular output work, in terms of aortic pressure and flow rate cooperated with the LPM, was used to characterize the VAC of ventricle and its afterload. The VAC subjected to the principle of minimal ventricular output work was validated by solving the Euler-Poisson equation of cost function, ultimately determining the waveforms of aortic pressure and flow rate. RESULTS: A third-order ODE can precisely describe the hemodynamic relationship between aortic pressure and flow rate. An optimized dual-source LPM with three energy-storage elements has been constructed, showing the potential in probing VAC under EECP. The LPM simulation results demonstrated that the VAC in terms of aortic pressure and flow rate yielded to the minimal ventricular output work under different EECP pressures. CONCLUSIONS: The ventricular-arterial coupling under EECP is subjected to the minimal ventricular output work, which can serve as a criterion for determining aortic pressure and flow rate. This study provides insight for the understanding of VAC and has the potential in characterizing the performance of the ventricular and arterial system under EECP.


Assuntos
Algoritmos , Contrapulsação , Ventrículos do Coração , Hemodinâmica , Modelos Cardiovasculares , Humanos , Contrapulsação/métodos , Débito Cardíaco , Artérias/fisiologia , Pressão Sanguínea , Simulação por Computador , Aorta/fisiologia , Redes Neurais de Computação
3.
J Biomech ; 166: 112057, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38520934

RESUMO

Enhanced external counterpulsation (EECP) is a treatment and rehabilitation approach for ischemic diseases, including coronary artery disease. Its therapeutic benefits are primarily attributed to the improved blood circulation achieved through sequential mechanical compression of the lower extremities. However, despite the crucial role that hemodynamic effects in the lower extremity arteries play in determining the effectiveness of EECP treatment, most studies have focused on the diastole phase and ignored the systolic phase. In the present study, a novel siphon model (SM) was developed to investigate the interdependence of several hemodynamic parameters, including pulse wave velocity, femoral flow rate, the operation pressure of cuffs, and the mean blood flow changes in the femoral artery throughout EECP therapy. To verify the accuracy of the SM, we coupled the predicted afterload in the lower extremity arteries during deflation using SM with the 0D-1D patient-specific model. Finally, the simulation results were compared with clinical measurements obtained during EECP therapy to verify the applicability and accuracy of the SM, as well as the coupling method. The precision and reliability of the previously developed personalized approach were further affirmed in this study. The average waveform similarity coefficient between the simulation results and the clinical measurements during the rest state exceeded 90%. This work has the potential to enhance our understanding of the hemodynamic mechanisms involved in EECP treatment and provide valuable insights for clinical decision-making.


Assuntos
Contrapulsação , Análise de Onda de Pulso , Humanos , Reprodutibilidade dos Testes , Hemodinâmica , Extremidade Inferior , Contrapulsação/métodos
4.
Artigo em Inglês | MEDLINE | ID: mdl-38419585

RESUMO

OBJECTIVES: We propose an evolution of a dielectric elastomer actuator-based cardiac assist device that acts as a counterpulsation system. We introduce a new pre-stretched actuator and implant the device in a graft bypass between the ascending and descending aorta to redirect all blood through the device (ascending aorta clamped). The objective was to evaluate the influence of these changes on the assistance provided to the heart. METHODS: The novel para-aortic device and the new implantation technique were tested in vivo in 5 pigs. We monitored the pressure and flow in the aorta as well as the pressure-volume characteristics of the left ventricle. Different activation timings were tested to identify the optimal device actuation. RESULTS: The proposed device helps reducing the end-diastolic pressure in the aorta by up to 13 ± 4.0% as well as the peak systolic pressure by up to 16 ± 3.6%. The early diastolic pressure was also increased up to 10 ± 3.5%. With different activation, we also showed that the device could increase or decrease the stroke volume. CONCLUSIONS: The new setup and the novel para-aortic device presented here helped improve cardiac assistance compared to previous studies. Moreover, we revealed a new way to assist the heart by actuating the device at different starting time to modify the left ventricular stroke volume and stroke work.

5.
Int J Numer Method Biomed Eng ; 40(4): e3808, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38409940

RESUMO

Diastolic/systolic blood pressure ratio (D/S) ≥ 1.2 is the gold standard of enhanced external counterpulsation (EECP) treatment, but it does not show a clear clinical correspondence with the configuration of the EECP mode. As such, a single target results in different treatment effects in different individuals. The local haemodynamic effect (wall shear stress, WSS) of EECP on vascular endothelial cells is conducive to promote the growth of collateral circulation vessels and restore the blood supply distal to the stenosis lesion. Considering the haemodynamic effects of WSS on human arteries, this study developed a real-time patient-specific treatment strategy of EECP for patients with cardio-cerebrovascular diseases. Based on patient-specific haemodynamic data from 113 individuals, an optimization algorithm was developed to achieve the individualization of a 0D lumped-parameter model of the human circulatory system, thereby simulating the patient-specific global haemodynamic effects. 0D/3D coupled cardio-cerebrovascular models of two subjects were established to simulate the local WSS. We then established statistical models to evaluate clinically unmeasurable WSS based on measurable global haemodynamic indicators. With the aim of attaining appropriate area- and time-averaged WSS (ATAWSS, 4-7 Pa), as evaluated by global haemodynamic indicators, a closed-loop feedback tuning method was developed to provide patient-specific EECP treatment strategies. Results showed that for clinical data collected from 113 individuals, the individualized 0D model can accurately simulate patient-specific global haemodynamic effects (average error <5%). Based on two subjects, the statistical models can be used to evaluate local ATAWSS (error <6%) for coronary arteries and for cerebral arteries. An EECP mode planned by the patient-specific treatment strategy can promote an appropriate ATAWSS within a 16 s calculation time. The real-time patient-specific treatment strategy of EECP is expected to improve the long-term outcome for each patient and have potential clinical significance.


Assuntos
Contrapulsação , Células Endoteliais , Humanos , Hemodinâmica , Pressão Sanguínea/fisiologia , Vasos Coronários , Contrapulsação/métodos
6.
J Affect Disord ; 350: 608-617, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38218261

RESUMO

PURPOSE: To investigate the short-term efficacy of enhanced external counterpulsation (EECP) on chronic insomnia. METHODS: This is a pilot randomized, participant-blind, and sham-controlled study. Forty-six participants with chronic insomnia were randomly assigned in a 1:1 ratio to receive EECP or sham EECP intervention (total of 35 sessions with 45 min each). The primary outcome was Pittsburgh Sleep Quality Index (PSQI). The secondary outcomes included sleep diary, Hospital Anxiety and Depression Scale (HADS), Short-Form Health Survey (SF12), flow mediated dilation (FMD), serum biomarkers of melatonin, cortisol, interleukin-6, and high sensitivity C-reactive protein. Outcomes were assessed after treatment and at 3-month follow-up. RESULTS: The PSQI was significantly decreased in both EECP and sham groups after 35-session intervention (13.74 to 6.96 in EECP and 13.04 to 9.48 in sham), and EECP decreased PSQI more than sham EECP (p = 0.009). PSQI in two groups kept improved at 3-month follow-up. After treatment, the total sleep time, sleep efficiency, FMD value and SF12 mental component of EECP group were significantly improved, and group differences were found for these outcomes. At follow-up, total sleep time, sleep efficiency and SF12 mental component of EECP group remained improved, and group difference for SF12 mental component was found. Post-treatment and follow-up HADS-A significantly decreased in both groups, with no differences between groups. Post-treatment serum biomarkers showed no differences within and between groups. LIMITATION: Lack of objective sleep measurement. CONCLUSION: EECP could improve sleep quality and mental quality of life in chronic insomnia and the therapeutic effect maintained for 3 months.


Assuntos
Contrapulsação , Distúrbios do Início e da Manutenção do Sono , Humanos , Distúrbios do Início e da Manutenção do Sono/terapia , Qualidade do Sono , Qualidade de Vida , Projetos Piloto , Biomarcadores , Resultado do Tratamento
8.
Saudi Med J ; 44(12): 1277-1282, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38016747

RESUMO

OBJECTIVES: To investigates the outcomes of enhanced external counterpulsation (EECP) among coronary microvascular disease (CMD) patients. METHODS: Coronary microvascular disease patients were separated into the EECP (n=41) and control cohorts (n=42). Prior to and following the 4-week EECP program, coronary flow reserve (CFR) was recorded using transthoracic Doppler echocardiography. The serum endothelial nitric oxide synthase (eNOS) and endothelin-1 (ET-1) contents were analyzed by ELISA. Quality of life (QoL) was assessed by the Seattle Angina Questionnaire (SAQ) and the Canadian Cardiovascular Society (CCS) angina class. RESULTS: After four weeks, CFR was substantially enhanced in the EECP versus control cohort (p<0.05). Endothelin-1 was strongly diminished whereas eNOS was considerably upregulated in the EECP cohort. EECP also enhanced patients' SAQ scores and decreased the CCS angina class. CONCLUSION: Enhanced external counterpulsation may improve CFR and enhance the CMD patient QoL.


Assuntos
Contrapulsação , Qualidade de Vida , Humanos , Endotelina-1 , Canadá , Angina Pectoris , Resultado do Tratamento
9.
Scand Cardiovasc J ; 57(1): 2273223, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37876280

RESUMO

OBJECTIVES: Enhanced external counterpulsation (EECP) is an effective and noninvasive treatment for patients with refractory angina and chronic heart failure. However, previous studies evaluating the influence of EECP on endothelial function showed inconsistent results. This systematic review and meta-analysis was conducted to evaluate the effects of EECP on endothelial function measured by brachial artery flow-mediated dilation (FMD). DESIGN: PubMed, Embase, Cochrane Library, CNKI, and Wanfang databases were searched for randomized controlled trials comparing the influence of EECP versus usual care on FMD in adult population. A random-effects model incorporating the potential influence of heterogeneity was used to pool the results. RESULTS: Nineteen studies with 1647 patients were included in the meta-analysis. Compared with usual care or conventional therapy, additional treatment with EECP for 3-7 weeks was associated with a significantly improved FMD (mean difference [MD]: 1.96%, 95% confidence interval [CI]: 1.57-2.36, p < 0.001, I2 = 52%). Subgroup analysis showed consistent results in patients with coronary artery disease and in patients with other diseases (p for subgroup difference = 0.21). Results of meta-regression analysis showed that the mean baseline FMD level was positively correlated with the influence of EECP on FMD (coefficient = 0.42, p < 0.001). Results of subgroup analysis suggested that the increment of FMD following EECP was larger in patients with baseline FMD ≥ 5% (MD: 2.69, 95% CI: 2.27-3.10, p < 0.001; I2 = 15%) compared to those with baseline FMD < 5% (MD: 1.49, 95% CI: 1.13-1.85, p < 0.001; I2 = 0%; p for subgroup difference < 0.001). CONCLUSIONS: EECP may be effective in improving endothelial function measured by FMD.


Assuntos
Doença da Artéria Coronariana , Contrapulsação , Adulto , Humanos , Vasodilatação , Ensaios Clínicos Controlados Aleatórios como Assunto , Angina Pectoris/terapia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Contrapulsação/efeitos adversos , Contrapulsação/métodos
10.
Asian Biomed (Res Rev News) ; 17(5): 208-221, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37899762

RESUMO

Background: Enhanced external counterpulsation (EECP) is provided by a noninvasive device positively affecting cardiovascular function via mechanisms called diastolic augmentation and systolic unloading. The renal aspects of EECP therapy have not been extensively investigated. Objectives: To assess the effect of EECP on renal function and to determine the application in patients with kidney disease. Methods: MEDLINE, EMBASE, SCOPUS, and Cochrane CENTRAL databases were searched for all studies involving EECP treatments. The title and abstract of all searched literatures were screened, and those focusing on renal outcome or conducting in kidney disease patients were selected. Results: Eight studies were included in the qualitative analysis. EECP increases stroke volume, mean arterial pressure, renal artery blood flow, renal plasma flow, glomerular filtration rate (GFR), plasma atrial natriuretic peptide, urine volume, and urinary sodium chloride excretion, but reduces the plasma concentration of renin and endothelin-1 in healthy subjects. A single session of EECP after radioactive contrast exposure could provide increased contrast clearance, and this reduces contrast-induced kidney injury in patients, irrespective of previous kidney function. Thirty-five-hour sessions of EECP treatment were illustrated to increase long-term estimated GFR in patients with chronic angina and heart failure. In cirrhotic patients, EECP fails to improve GFR and renal vascular resistance. EECP device could maintain blood pressure, decrease angina symptoms, and increase cardiac perfusion in hemodialysis patients. Conclusion: EECP treatment potentially increases renal perfusion and prevents kidney injury in several conditions. EECP possibly provides beneficial effects on hemodynamics and cardiac function in hemodialysis patients.

11.
J Biomech ; 159: 111777, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37666100

RESUMO

Dielectric elastomer actuator augmented aorta (DEA) represents a novel approach with high potential for assisting a failing heart. The soft tubular device replaces a section of the aorta and increases its diameter when activated. The hemodynamic interaction between the DEA and the left ventricle (LV) has not been investigated with wave intensity (WI) analysis before. The objective of this study is to investigate the hemodynamic effects of the DEA on the aortic WI pattern. WI was calculated from aortic pressure and flow measured in-vivo in the descending aorta of two pigs implanted with DEAs. The DEAs were tested for different actuation phase shifts (PS). The DEA generated two decompression waves (traveling upstream and downstream of the device) at activation followed by two compression waves at deactivation. Depending on the PS, the end-diastolic pressure (EDP) decreased by 7% (or increased by 5-6%). The average early diastolic pressure augmentation (Pdia¯) increased by 2% (or decreased by 2-3%). The hydraulic work (WH) measured in the aorta decreased by 2% (or increased by 5%). The DEA-generated waves interfered with the LV-generated waves, and the timing of the waves affected the hemodynamic effect of the device. For the best actuation timing the upstream decompression wave arrived just before aortic valve opening and the upstream compression wave arrived just before aortic valve closure leading to a decreased EDP, an increased Pdia¯ and a reduced.WH.


Assuntos
Aorta , Hemodinâmica , Suínos , Animais , Aorta/fisiologia , Pressão Sanguínea , Coração , Pressão Arterial
12.
J Int Med Res ; 51(9): 3000605231194514, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37728598

RESUMO

We describe a young woman with patent foramen ovale who developed multiple retinal artery occlusion in the right eye after injection of hyaluronic acid into the nasal root. She reported a gradual decline in visual acuity, with visual field defects that had developed in two stages. Multiple retinal artery occlusion was confirmed by slit-lamp examination, dilated fundus examination, optical coherence tomography, visual field examination, and fundus fluorescein angiography. A patent foramen ovale was detected by electrocardiography, transesophageal echocardiography, and transthoracic sonography. The patient was treated with intravenous dexamethasone and cobamamide, as well as extracorporeal counterpulsation therapy; this approach has not been described in previous literature regarding retinal artery occlusion. The patient's visual acuity improved from counting fingers at 30 cm to 20/133 within 3 days. Our report emphasizes the need for better understanding of vascular anatomy to minimize the risk of complications. Moreover, patients undergoing hyaluronic acid injection should receive information regarding the potential for mild and severe complications; relevant tests should be performed before surgery to exclude vulnerable patients. Finally, a nursing system is needed to facilitate the emergency recognition, triage, and management of retinal artery occlusion.


Assuntos
Forame Oval Patente , Oclusão da Artéria Retiniana , Feminino , Humanos , Forame Oval Patente/complicações , Ácido Hialurônico/efeitos adversos , Face , Oclusão da Artéria Retiniana/induzido quimicamente , Nariz
13.
J Biomech ; 159: 111797, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37703718

RESUMO

As a non-invasive assisted circulation therapy, enhanced external counterpulsation (EECP) has demonstrated potential in treatment of lower-extremity arterial disease (LEAD). However, the underlying hemodynamic mechanism remains unclear. This study aimed to conduct the first prospective investigation of the EECP-induced responses of blood flow behavior and wall shear stress (WSS) metrics in the femoral artery. Twelve healthy male volunteers were enrolled. A Doppler ultrasound-basedapproach was introduced for the in vivo determination of blood flow in the common femoral artery (CFA) and superficial femoral artery (SFA) during EECP intervention, with incremental treatment pressures ranging from 10 to 40 kPa. Three-dimensional subject-specific numerical models were developed in 6 subjects to quantitatively assess variations in WSS-derived hemodynamic metrics in the femoral bifurcation. A mesh-independence analysis was performed. Our results indicated that, compared to the pre-EECP condition, both the antegrade and retrograde blood flow volumes in the CFA and SFA were significantly augmented during EECP intervention, while the heart rate remained constant. The time average shear stress (TAWSS) over the entire femoral bifurcation increased by 32.41%, 121.30%, 178.24%, and 214.81% during EECP with treatment pressures of 10 kPa, 20 kPa, 30 kPa, and 40 kPa, respectively. The mean relative resident time (RRT) decreased by 24.53%, 61.01%, 69.81%, and 77.99%, respectively. The percentage of area with low TAWSS in the femoral artery dropped to nearly zero during EECP with a treatment pressure greater than or equal to 30 kPa. We suggest that EECP is an effective and non-invasive approach for regulating blood flow and WSS in lower extremity arteries.


Assuntos
Contrapulsação , Artéria Femoral , Humanos , Masculino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiologia , Voluntários Saudáveis , Estudos Prospectivos , Hemodinâmica , Extremidade Inferior , Contrapulsação/métodos
14.
Curr Cardiol Rep ; 25(10): 1291-1298, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37642929

RESUMO

PURPOSE OF REVIEW: Heart failure is a serious global health problem, and coronary artery disease is one of the main causes. At present, the treatment options for ischemic heart failure (IHF) are limited. This article mainly aims to explore the evidence of enhanced external counterpulsation (EECP) as a non-invasive cardiac rehabilitation method in patients with IHF and to make a preliminary exploration of its mechanisms. RECENT FINDINGS: According to the existing evidence, the standard course of EECP is safe in patients with IHF and can significantly improve the quality of life of these patients. The effect of EECP on systolic function is still unclear, while EECP has a significant improvement effect on cardiac diastolic function. At the same time, this treatment can reduce the re-hospitalization rate and emergency visit rate of patients within 6 months. In terms of mechanisms, in addition to the immediate hemodynamic effect, existing evidence mostly suggests that its improvement of cardiac function may come from its upregulation of shear stress to improve myocardial perfusion. EECP is safe to use in patients with stable ischemic heart failure, and it can improve the performance status of patients and may be beneficial to cardiac function and reduce the short-term re-hospitalization rate.


Assuntos
Doença da Artéria Coronariana , Contrapulsação , Insuficiência Cardíaca , Humanos , Qualidade de Vida , Insuficiência Cardíaca/terapia , Hemodinâmica , Contrapulsação/métodos
15.
Comput Methods Programs Biomed ; 239: 107640, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37271049

RESUMO

BACKGROUND AND OBJECTIVES: Currently, enhanced external counterpulsation (EECP) devices mainly produce one counterpulsation per cardiac cycle. However, the effect of other frequencies of EECP on the hemodynamics of coronary and cerebral arteries is still unclear. It should be investigated whether one counterpulsation per cardiac cycle leads to the optimal therapeutic effect in patients with different clinical indications. Therefore, we measured the effects of different frequencies of EECP on the hemodynamics of coronary and cerebral arteries to determine the optimal counterpulsation frequency for the treatment of coronary heart disease and cerebral ischemic stroke. METHODS: We established 0D/3D geometric multi-scale hemodynamics model of coronary and cerebral arteries in two healthy individuals, and performed clinical trials of EECP to verify the accuracy of the multi-scale hemodynamics model. The pressure amplitude (35 kPa) and pressurization duration (0.6 s) were fixed. The global and local hemodynamics of coronary and cerebral arteries were studied by changing counterpulsation frequency. Three frequency modes, including one counterpulsation in one, two and three cardiac cycles, were applied. Global hemodynamic indicators included diastolic / systolic blood pressure (D/S), mean arterial pressure (MAP), coronary artery flow (CAF), and cerebral blood flow (CBF), whereas local hemodynamic effects included area-time-averaged wall shear stress (ATAWSS) and oscillatory shear index (OSI). The optimal counterpulsation frequency was verified by analyzing the hemodynamic effects of different frequency modes of counterpulsation cycles and full cycles. RESULTS: In the full cycle, CAF, CBF and ATAWSS of coronary and cerebral arteries were the highest when one counterpulsation per cardiac cycle was applied. However, in the counterpulsation cycle, the global and local hemodynamic indicators of coronary and cerebral artery reached the highest when one counterpulsation in one cardiac cycle or two cardiac cycles was applied. CONCLUSIONS: For clinical application, the results of global hemodynamic indicators in the full cycle have more clinical practical significance. Combined with the comprehensive analysis of local hemodynamic indicators, it can be concluded that for coronary heart disease and cerebral ischemic stroke, applying one counterpulsation per cardiac cycle may provide the optimal benefit.


Assuntos
Doença das Coronárias , Contrapulsação , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Doença das Coronárias/terapia , Hemodinâmica , Acidente Vascular Cerebral/terapia , Vasos Coronários , Contrapulsação/métodos
16.
Front Neurosci ; 17: 1197598, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37351421

RESUMO

Introduction: Enhanced external counterpulsation (EECP) is a non-invasive assisted circulation technique for its clinical application in the rehabilitation and management of ischemic cardiovascular and cerebrovascular diseases, which has complex physiological and hemodynamic effects. However, the effects of EECP on the coupling of physiological systems are still unclear. We aimed to investigate the immediate effects of EECP on the coupling between integrated physiological systems such as cardiorespiratory and cardiovascular systems. Methods: Based on a random sham-controlled design, simultaneous electrocardiography, photoplethysmography, bio-electrical impedance, and continuous hemodynamic data were recorded before, during and after two consecutive 30 min EECP in 41 healthy adults. Physiological coupling strength quantified by phase synchronization indexes (PSI), hemodynamic measurements and heart rate variability indices of 22 subjects (female/male: 10/12; age: 22.6 ± 2.1 years) receiving active EECP were calculated and compared with those of 19 sham control subjects (female/male: 7/12; age: 23.6 ± 2.5 years). Results: Immediately after the two consecutive EECP interventions, the physiological coupling between respiratory and cardiovascular systems PSIRES-PTT (0.34 ± 0.14 vs. 0.49 ± 0.17, P = 0.002), the physiological coupling between cardiac and cardiovascular systems PSIIBI-PTT (0.41 ± 0.14 vs. 0.52 ± 0.16, P = 0.006) and the total physiological coupling PSItotal (1.21 ± 0.35 vs. 1.57 ± 0.49, P = 0.005) in the EECP group were significantly lower than those before the EECP intervention, while the physiological coupling indexes in the control group did not change significantly (P > 0.05). Conclusion: Our study provides evidence that the PSI is altered by immediate EECP intervention. We speculate that the reduced PSI induced by EECP may be a marker of disturbed physiological coupling. This study provides a new method for exploring the mechanism of EECP action and may help to further optimize the EECP technique.

17.
J Cereb Blood Flow Metab ; 43(10): 1764-1778, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37254770

RESUMO

Enhanced external counterpulsation (EECP) treatment for cerebral ischemic stroke patients with differing severity of stenosis, is subject to uncertainties due to the varying effects of the cerebral autoregulation mechanism on haemodynamics. The current study reports the development of a cerebral multi-autoregulation (MR) mathematical model, based on cerebral arteriole regulation of neurogenic, vascular smooth muscle reflex and shear stress mechanisms which takes into account the severity of stenosis. The model was evaluated by comparison to authentic clinical measurements of cerebral autoregulatory efficiency. Then it was applied to a 0D/3D geometric multi-scale haemodynamic model of a cerebral artery. Haemodynamic indicators were calculated under different pressurization durations of EECP to evaluate the efficacy for different stenosis lesions. Moderate stenosis of 50% to 60% produced excessive time-averaged wall shear stress in the distal area of the stenosis (>7 Pa) during prolonged pressurization and may result in damage to vascular endothelial cells. However, prolonged pressurization did not result in haemodynamic risk for severe stenosis of 70% to 80%, indicating that the duration of pressurization may be extended with increasing severity of stenosis. The current MR model accurately simulated cerebral blood flow and has relevance to the simulation of cerebral haemodynamics in a clinical setting.


Assuntos
Contrapulsação , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Células Endoteliais , Constrição Patológica , Acidente Vascular Cerebral/terapia , Homeostase
18.
Curr Pharm Des ; 29(23): 1825-1834, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37183474

RESUMO

Coronary artery disease remains a condition with high prevalence and detrimental effects on the quality of life of affected individuals. Its most frequent manifestation, stable angina pectoris, may be challenging to manage despite the available antianginal pharmacotherapy and adequate risk factor control, especially in subjects not amenable to revascularization. In the direction of refractory angina pectoris, several approaches have been developed over the years with varying degrees of success. Among the most recognized techniques in managing angina is enhanced external counterpulsation, which utilizes mechanical compression of the lower extremities to increase blood flow to the heart. Moving to coronary sinus reduction, it leads to an increase in coronary sinus backward pressure, ultimately augmenting myocardial blood flow redistribution to ischemic regions and ameliorating chronic angina. Clinical trial results of the above-mentioned techniques have been encouraging but are based on small sample sizes to justify their widespread application. Other interventional approaches, such as transmyocardial laser revascularization, extracorporeal shockwave myocardial revascularization, and spinal cord stimulation, have been met with either controversial or negative results, and their use is not recommended. Lastly, angiogenic therapy with targeted intramyocardial vascular endothelial growth factor injection or CD34+ cell therapy may be beneficial and warrants further investigation. In this review, we summarize the current knowledge in the field of angina management, highlighting the potential and the gaps in the existing evidence that ought to be addressed in future larger-scale, randomized studies before these techniques can be safely adapted in the clinical practice of patients with refractory angina pectoris.


Assuntos
Doença da Artéria Coronariana , Humanos , Doença da Artéria Coronariana/terapia , Qualidade de Vida , Fator A de Crescimento do Endotélio Vascular , Angina Pectoris/tratamento farmacológico , Revascularização Miocárdica/métodos
19.
Front Physiol ; 14: 1144073, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37078023

RESUMO

Introduction: Accumulating evidence suggests that enhanced external counterpulsation (EECP) influences cardiac functions, hemodynamic characteristics and cerebral blood flow. However, little is known about whether or how the EECP affects the brain-heart coupling to produce these physiological and functional changes. We aimed to determine if the brain-heart coupling is altered during or after EECP intervention by assessing the heartbeat evoked potential (HEP) in healthy adults. Methods: Based on a random sham-controlled design, simultaneous electroencephalography and electrocardiography signals as well as blood pressure and flow status data were recorded before, during and after two consecutive 30-min EECP in 40 healthy adults (female/male: 17/23; age: 23.1 ± 2.3 years). HEP amplitude, frequency domain heart rate variability, electroencephalographic power and hemodynamic measurements of 21 subjects (female/male: 10/11; age: 22.7 ± 2.1 years) receiving active EECP were calculated and compared with those of 19 sham control subjects (female/male: 7/12; age: 23.6 ± 2.5 years). Results: EECP intervention caused immediate obvious fluctuations of HEP from 100 to 400 ms after T-peak and increased HEP amplitudes in the (155-169) ms, (354-389) ms and (367-387) ms time windows after T-peak in the region of the frontal pole lobe. The modifications in HEP amplitude were not associated with changes in the analyzed significant physiological measurements and hemodynamic variables. Discussion: Our study provides evidence that the HEP is modulated by immediate EECP stimuli. We speculate that the increased HEP induced by EECP may be a marker of enhanced brain-heart coupling. HEP may serve as a candidate biomarker for the effects and responsiveness to EECP.

20.
Clin Exp Hypertens ; 45(1): 2181355, 2023 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-36871563

RESUMO

OBJECTIVE: Endothelial function may improve with enhanced external counterpulsation (EECP) or acupuncture. This study aimed to evaluate the feasibility of acupoint stimulation combined with EECP (acupoint-EECP) for endothelial cell function in patients with essential hypertension. METHODS: Thirty essential hypertensive patients were, randomly divided into two groups, with 15 patients in the acupoint-EECP group, and 15 patients in the control group, of which 3 cases were lost by week 6. Both groups were treated with continued medicine. The participants in the acupoint-EECP group received acupoint stimulation combined with EECP therapy, 45 min for each time, 5 times weekly for 6 weeks for a total of 22.5 hours. The selected acupoints are Zusanli (ST36), Fenglong (ST40) and Sanyinjiao (SP6). The curative effects of the two groups were compared. RESULTS: The acupoint-EECP group (n=15) showed significant improvement in endothelial function [nitric oxide (NO) ,endothelin-1 (ET-1) and carotid-femoral pulse wave velocity (cf-PWV), respectively] values compared to the control group (n=12). Multiple imputation (n = 20 imputations) was performed to account for potential bias due to missing data. In stratified analyses, SBP and DBP values decreased when the baseline SBP was ≥120 mmHg and DBP was ≥80 mmHg. CONCLUSIONS: These findings suggest the feasibility of acupoint-EECP in improving endothelial function and treating hypertension. (The Chinese clinical trial registration number is ChiCTR2100053795.).


Assuntos
Terapia por Acupuntura , Contrapulsação , Hipertensão , Humanos , Projetos Piloto , Análise de Onda de Pulso
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...