Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Restor Dent Endod ; 42(3): 224-231, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28808639

RESUMO

OBJECTIVES: To determine the actual revolutions per minute (rpm) values and compare the cyclic fatigue life of Reciproc (RPC, VDW GmbH), WaveOne (WO, Dentsply Maillefer), and TF Adaptive (TFA, Axis/SybronEndo) nickel-titanium (NiTi) file systems using high-speed camera. MATERIALS AND METHODS: Twenty RPC R25 (25/0.08), 20 WO Primary (25/0.08), and 20 TFA ML 1 (25/0.08) files were employed in the present study. The cyclic fatigue tests were performed using a dynamic cyclic fatigue testing device, which has an artificial stainless steel canal with a 60° angle of curvature and a 5-mm radius of curvature. The files were divided into 3 groups (group 1, RPC R25 [RPC]; group 2, WO Primary [WO]; group 3, TF Adaptive ML 1 [TFA]). All the instruments were rotated until fracture during the cyclic fatigue test and slow-motion videos were captured using high-speed camera. The number of cycles to failure (NCF) was calculated. The data were analyzed statistically using one-way analysis of variance (ANOVA, p < 0.05). RESULTS: The slow-motion videos were indicated that rpm values of the RPC, WO, and TFA groups were 180, 210, and 425, respectively. RPC (3,464.45 ± 487.58) and WO (3,257.63 ± 556.39) groups had significantly longer cyclic fatigue life compared with TFA (1,634.46 ± 300.03) group (p < 0.05). There was no significant difference in the mean length of the fractured fragments. CONCLUSIONS: Within the limitation of the present study, RPC and WO NiTi files showed significantly longer cyclic fatigue life than TFA NiTi file.

2.
J Formos Med Assoc ; 116(4): 306-312, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27375047

RESUMO

BACKGROUND/PURPOSE: Dental rotary instruments can be applied in multiple conditions of canals, but unpredictable fatigue fracture may happen. This study evaluated the fatigue lives of two batches of nickel-titanium (NiTi) dental rotary files operating in clinically simulated root canals. METHODS: Single-step cyclic fatigue tests were carried out to assess the performance of two batches of NiTi files (ProTaper and ProFile) in nine combinations of simulated canals (cylinder radii 5 mm, 7.5 mm, and 10 mm, and insertion angles 20°, 40°, and 60°). Two-step cyclic fatigue tests were carried out in simulated root canals with the same radius by using the following two sets of insertion angles: (20°, 40°), (20°, 60°), (40°, 20°), and (60°, 20°). Fracture surfaces were observed by scanning electron microscopy. RESULTS: The single-step cyclic fatigue results showed that cyclic fatigue lives of the files decreased with increasing insertion angles or decreasing cylinder radius. The ProFile #25 .04 file was more fatigue resistant than the ProTaper F2 file. In two-step cyclic fatigue tests, the total fatigue lives were usually more than 100% when the files operated at a lower strain and then at a higher strain. By scanning electron microscopy, a larger area of fatigue striation corresponded to a longer fatigue life. CONCLUSION: Cyclic fatigue life can be influenced by the strains and geometries of files. The fatigue life was prolonged when the files operated at a lower strain and then at a higher strain. However, the fatigue life was shortened if the loading sequence was reversed.


Assuntos
Teste de Materiais/métodos , Níquel , Preparo de Canal Radicular/instrumentação , Titânio , Análise do Estresse Dentário , Desenho de Equipamento , Falha de Equipamento , Humanos , Teste de Materiais/instrumentação , Microscopia Eletrônica de Varredura , Rotação , Estresse Mecânico
3.
J Dent Sci ; 12(1): 21-26, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30895019

RESUMO

BACKGROUND/PURPOSE: Heat pretreatment can improve the cyclic fatigue life of nickel-titanium (NiTi) instruments. This study evaluated the effects of two different heat treatments on the cyclic fatigue resistance and cutting efficiency of ProTaper Universal F2 files. MATERIALS AND METHODS: The files were divided into three groups: no treatment (control), heat treatment at 400°C (HT400) and heat treatment at 600°C (HT600). The phase transformation of the files was evaluated by differential scanning calorimetry. In cyclic fatigue tests, the differences in file performance in four simulated canals among the three groups were assessed. The cutting efficiency was tested at four cutting portions (3 mm, 6 mm, 9 mm, and 12 mm) from the tip of the file. RESULTS: Differential scanning calorimetry showed a prolonged phase transformation of the files only after 600°C treatment. At 3 mm cutting portion, 400°C heat-treated files had significantly better cutting ability than those in the control group. However, the files in the HT600 group had significantly lower cutting efficiency than those in the other two groups at the four tested positions. In the cyclic fatigue test, fatigue lives of the files after 400°C and 600°C treatment were prolonged from 2.1 to 2.8 times and from 1.7 to 5.5 times, respectively. CONCLUSION: Although 600°C treatment increased resistance to cyclic fatigue, it reduced the cutting efficiency of the files. The 400°C treatment maintained the cutting ability and prolonged the cyclic fatigue life of the files. Therefore, for clinical use of ProTaper Universal F2 files, 400°C pretreatment is a better choice than 600°C pretreatment.

4.
J Formos Med Assoc ; 116(5): 373-379, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27502895

RESUMO

BACKGROUND/PURPOSE: Dental nickel-titanium (NiTi) rotary instruments are widely used in endodontic therapy because they are efficient with a higher success rate. However, an unpredictable fracture of instruments may happen due to the surface characteristics of imperfection (or irregularity). This study assessed whether a novel surface treatment could increase fatigue fracture resistance of dental NiTi rotary instruments. METHODS: A 200- or 500-nm thick Ti-zirconium-boron (Ti-Zr-B) thin film metallic glass was deposited on ProTaper Universal F2 files using a physical vapor deposition process. The characteristics of coating were analyzed by scanning electron microscopy, transmission electron microscopy, and X-ray diffractometry. In cyclic fatigue tests, the files were performed in a simulated root canal (radius=5 mm, angulation=60°) under a rotating speed of 300rpm. The fatigue fractured cross sections of the files were analyzed with their fractographic performances through scanning electron microscopy images. RESULTS: The amorphous structure of the Ti-Zr-B coating was confirmed by transmission electron microscopy and X-ray diffractometry. The surface of treated files presented smooth morphologies without grinding irregularity. For the 200- and 500-nm surface treatment groups, the coated files exhibited higher resistance of cyclic fatigue than untreated files. In fractographic analysis, treated files showed significantly larger crack-initiation zone; however, no significant differences in the areas of fatigue propagation and catastrophic fracture were found compared to untreated files. CONCLUSION: The novel surface treatment of Ti-Zr-B thin film metallic glass on dental NiTi rotary files can effectively improve the fatigue fracture resistance by offering a smooth coated surface with amorphous microstructure.


Assuntos
Ligas Dentárias/uso terapêutico , Instrumentos Odontológicos/efeitos adversos , Preparo de Canal Radicular/métodos , Propriedades de Superfície , Fraturas dos Dentes/prevenção & controle , Ligas , Boro/administração & dosagem , Falha de Equipamento , Vidro , Humanos , Teste de Materiais , Preparo de Canal Radicular/efeitos adversos , Preparo de Canal Radicular/instrumentação , Titânio/administração & dosagem , Fraturas dos Dentes/etiologia , Oligoelementos/administração & dosagem , Zircônio/administração & dosagem
5.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-23634

RESUMO

OBJECTIVES: To determine the actual revolutions per minute (rpm) values and compare the cyclic fatigue life of Reciproc (RPC, VDW GmbH), WaveOne (WO, Dentsply Maillefer), and TF Adaptive (TFA, Axis/SybronEndo) nickel-titanium (NiTi) file systems using high-speed camera. MATERIALS AND METHODS: Twenty RPC R25 (25/0.08), 20 WO Primary (25/0.08), and 20 TFA ML 1 (25/0.08) files were employed in the present study. The cyclic fatigue tests were performed using a dynamic cyclic fatigue testing device, which has an artificial stainless steel canal with a 60° angle of curvature and a 5-mm radius of curvature. The files were divided into 3 groups (group 1, RPC R25 [RPC]; group 2, WO Primary [WO]; group 3, TF Adaptive ML 1 [TFA]). All the instruments were rotated until fracture during the cyclic fatigue test and slow-motion videos were captured using high-speed camera. The number of cycles to failure (NCF) was calculated. The data were analyzed statistically using one-way analysis of variance (ANOVA, p < 0.05). RESULTS: The slow-motion videos were indicated that rpm values of the RPC, WO, and TFA groups were 180, 210, and 425, respectively. RPC (3,464.45 ± 487.58) and WO (3,257.63 ± 556.39) groups had significantly longer cyclic fatigue life compared with TFA (1,634.46 ± 300.03) group (p < 0.05). There was no significant difference in the mean length of the fractured fragments. CONCLUSIONS: Within the limitation of the present study, RPC and WO NiTi files showed significantly longer cyclic fatigue life than TFA NiTi file.


Assuntos
Fadiga , Rádio (Anatomia) , Aço Inoxidável
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...