Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 397
Filtrar
1.
Comput Struct Biotechnol J ; 24: 434-450, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38975287

RESUMO

A medical data integration center integrates a large volume of medical images from clinical departments, including X-rays, CT scans, and MRI scans. Ideally, all images should be indexed appropriately with standard clinical terms. However, some images have incorrect or missing annotations, which creates challenges in searching and integrating data centrally. To address this issue, accurate and meaningful descriptors are needed for indexing fields, enabling users to efficiently search for desired images and integrate them with international standards. This paper aims to provide concise annotation for missing or incorrectly indexed fields, incorporating essential instance-level information such as radiology modalities (e.g., X-rays), anatomical regions (e.g., chest), and body orientations (e.g., lateral) using a Deep Learning classification model - ResNet50. To demonstrate the capabilities of our algorithm in generating annotations for indexing fields, we conducted three experiments using two open-source datasets, the ROCO dataset, and the IRMA dataset, along with a custom dataset featuring SNOMED CT labels. While the outcomes of these experiments are satisfactory (Precision of >75%) for less critical tasks and serve as a valuable testing ground for image retrieval, they also underscore the need for further exploration of potential challenges. This essay elaborates on the identified issues and presents well-founded recommendations for refining and advancing our proposed approach.

2.
Abdom Radiol (NY) ; 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38860997

RESUMO

Accurate, automated MRI series identification is important for many applications, including display ("hanging") protocols, machine learning, and radiomics. The use of the series description or a pixel-based classifier each has limitations. We demonstrate a combined approach utilizing a DICOM metadata-based classifier and selective use of a pixel-based classifier to identify abdominal MRI series. The metadata classifier was assessed alone as Group metadata and combined with selective use of the pixel-based classifier for predictions with less than 70% certainty (Group combined). The overall accuracy (mean and 95% confidence intervals) for Groups metadata and combined on the test dataset were 0.870 CI (0.824,0.912) and 0.930 CI (0.893,0.963), respectively. With this combined metadata and pixel-based approach, we demonstrate accurate classification of 95% or greater for all pre-contrast MRI series and improved performance for some post-contrast series.

3.
Neuroinformatics ; 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38861098

RESUMO

Pooling data across diverse sources acquired by multisite consortia requires compliance with a predefined reference protocol i.e., ensuring different sites and scanners for a given project have used identical or compatible MR physics parameter values. Traditionally, this has been an arduous and manual process due to difficulties in working with the complicated DICOM standard and lack of resources allocated towards protocol compliance. Moreover, issues of protocol compliance is often overlooked for lack of realization that parameter values are routinely improvised/modified locally at various sites. The inconsistencies in acquisition protocols can reduce SNR, statistical power, and in the worst case, may invalidate the results altogether. An open-source tool, mrQA was developed to automatically assess protocol compliance on standard dataset formats such as DICOM and BIDS, and to study the patterns of non-compliance in over 20 open neuroimaging datasets, including the large ABCD study. The results demonstrate that the lack of compliance is rather pervasive. The frequent sources of non-compliance include but are not limited to deviations in Repetition Time, Echo Time, Flip Angle, and Phase Encoding Direction. It was also observed that GE and Philips scanners exhibited higher rates of non-compliance relative to the Siemens scanners in the ABCD dataset. Continuous monitoring for protocol compliance is strongly recommended before any pre/post-processing, ideally right after the acquisition, to avoid the silent propagation of severe/subtle issues. Although, this study focuses on neuroimaging datasets, the proposed tool mrQA can work with any DICOM-based datasets.

4.
Radiother Oncol ; : 110289, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38944554

RESUMO

BACKGROUND AND PURPOSE: Guideline adherence in radiotherapy is crucial for maintaining treatment quality and consistency, particularly in non-trial patient settings where most treatments occur. The study aimed to assess the impact of guideline changes on treatment planning practices and compare manual registry data accuracy with treatment planning data. MATERIALS AND METHODS: This study utilised the DBCG RT Nation cohort, a collection of breast cancer radiotherapy data in Denmark, to evaluate adherence to guidelines from 2008 to 2016. The cohort included 7448 high-risk breast cancer patients. National guideline changes included, fractionation, introduction of respiratory gating, irradiation of the internal mammary lymph nodes, use of the simultaneous integrated boost technique and inclusion of the Left Anterior Descending coronary artery in delineation practice. Methods for structure name mapping, laterality detection, detection of temporal changes in population mean lung volume, and dose evaluation were presented and applied. Manually registered treatment characteristic data was obtained from the Danish Breast Cancer Database for comparison. RESULTS: The study found immediate and consistent adherence to guideline changes across Danish radiotherapy centres. Treatment practices before guideline implementation were documented and showed a variation among centres. Discrepancies between manual registry data and actual treatment planning data were as high as 10% for some measures. CONCLUSION: National guideline changes could be detected in the routine treatment data, with a high degree of compliance and short implementation time. Data extracted from treatment planning data files provides a more accurate and detailed characterisation of treatments and guideline adherence than medical register data.

5.
Comput Med Imaging Graph ; 116: 102411, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38924800

RESUMO

Radiomics is an innovative field in Personalized Medicine to help medical specialists in diagnosis and prognosis. Mainly, the application of Radiomics to medical images requires the definition and delimitation of the Region Of Interest (ROI) on the medical image to extract radiomic features. The aim of this preliminary study is to define an approach that automatically detects the specific areas indicative of a particular disease and examines them to minimize diagnostic errors associated with false positives and false negatives. This approach aims to create a nxn grid on the DICOM image sequence and each cell in the matrix is associated with a region from which radiomic features can be extracted. The proposed procedure uses the Model Checking technique and produces as output the medical diagnosis of the patient, i.e., whether the patient under analysis is affected or not by a specific disease. Furthermore, the matrix-based method also localizes where appears the disease marks. To evaluate the performance of the proposed methodology, a case study on COVID-19 disease is used. Both results on disease identification and localization seem very promising. Furthermore, this proposed approach yields better results compared to methods based on the extraction of features using the whole image as a single ROI, as evidenced by improvements in Accuracy and especially Recall. Our approach supports the advancement of knowledge, interoperability and trust in the software tool, fostering collaboration among doctors, staff and Radiomics.

6.
Craniomaxillofac Trauma Reconstr ; 17(2): 169-172, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38779392

RESUMO

Study Design: Technical note. Objective: Changes in orbital volume can lead to esthetic and functional complications of the orbit. In this article, the procedure to calculate the orbital volume using the open source software Aliza 3D DICOM is described. Methods: This article describes the steps to use this novel software. To validate the software, the normal orbital volume was calculated bilaterally on CT scans with normal orbital anatomy. The volumes of unilateral orbitozygomatic fracture cases were compared. Results: This open source software has easy access. The normal orbital volume calculated using this software was 24.4 cc ± 0.72. In the unilateral orbitozygomatic fracture cases, an increased orbital volume was calculated. Conclusions: This easy access, inexpensive, and convenient computer aided software can be used to calculate orbital volume facilitating treatment plan for correction of the orbit volume.

7.
ArXiv ; 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38764595

RESUMO

Hyperpolarized (HP) 13C MRI has shown promise as a valuable modality for in vivo measurements of metabolism and is currently in human trials at 15 research sites worldwide. With this growth it is important to adopt standardized data storage practices as it will allow sites to meaningfully compare data. In this paper we (1) describe data that we believe should be stored and (2) demonstrate pipelines and methods that utilize the Digital Imaging and Communications in Medicine (DICOM) standard. This includes proposing a set of minimum set of information that is specific to HP 13C MRI studies. We then show where the majority of these can be fit into existing DICOM Attributes, primarily via the "Contrast/Bolus" module. We also demonstrate pipelines for utilizing DICOM for HP 13C MRI. DICOM is the most common standard for clinical medical image storage and provides the flexibility to accommodate the unique aspects of HP 13C MRI, including the HP agent information but also spectroscopic and metabolite dimensions. The pipelines shown include creating DICOM objects for studies on human and animal imaging systems with various pulse sequences. We also show a python-based method to efficiently modify DICOM objects to incorporate the unique HP 13C MRI information that is not captured by existing pipelines. Moreover, we propose best practices for HP 13C MRI data storage that will support future multi-site trials, research studies and technical developments of this imaging technique.

8.
J Imaging Inform Med ; 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38710970

RESUMO

Hyperpolarized (HP) 13C MRI has shown promise as a valuable modality for in vivo measurements of metabolism and is currently in human trials at 15 research sites worldwide. With this growth, it is important to adopt standardized data storage practices as it will allow sites to meaningfully compare data. In this paper, we (1) describe data that we believe should be stored and (2) demonstrate pipelines and methods that utilize the Digital Imaging and Communications in Medicine (DICOM) standard. This includes proposing a set of minimum set of information that is specific to HP 13C MRI studies. We then show where the majority of these can be fit into existing DICOM attributes, primarily via the "Contrast/Bolus" module. We also demonstrate pipelines for utilizing DICOM for HP 13C MRI. DICOM is the most common standard for clinical medical image storage and provides the flexibility to accommodate the unique aspects of HP 13C MRI, including the HP agent information but also spectroscopic and metabolite dimensions. The pipelines shown include creating DICOM objects for studies on human and animal imaging systems with various pulse sequences. We also show a python-based method to efficiently modify DICOM objects to incorporate the unique HP 13C MRI information that is not captured by existing pipelines. Moreover, we propose best practices for HP 13C MRI data storage that will support future multi-site trials, research studies, and technical developments of this imaging technique.

9.
Comput Biol Med ; 176: 108553, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38723397

RESUMO

INTRODUCTION: Tissue establishments are responsible for processing, testing, preserving, storing, and distributing allografts from donors to be transplanted into recipients. In some situations, a matching process is required to determine the allograft that best fits the recipient. Allograft morphology is a key consideration for the matching process. The manual procedures applied to obtain these parameters make the process error-prone. MATERIAL AND METHODS: A new system to manage bone allograft-recipient matching for tissue establishments is proposed. The system requires bone allografts to be digitalized and the resulting images to be stored in a DICOM file. The system provides functionalities to: (i) manage DICOM files (registered in the PACs) from both allografts and recipients; (ii) reconstruct 3D models from DICOM images; (iii) explore 3D models using 2D, 3D, and multiplanar reconstructions; (iv) take allograft and recipient measurements; and (v) visualize and interact with recipient and allograft data simultaneously. The system has been installed in the Barcelona Tissue Bank (Banc de Sang i Teixits), which has digitalized the bone allografts to test the system. RESULTS: A use case with a femur is presented to test all the viewer functionalities. In addition, the recipient-allograft workflow is evaluated to show the steps of the procedure where the viewer can be used. CONCLUSIONS: The bone allograft-recipient matching procedure can be optimized using software tools with functionalities to visualize, interact, and take measurements.


Assuntos
Aloenxertos , Transplante Ósseo , Humanos , Transplante Ósseo/métodos , Software , Imageamento Tridimensional/métodos , Fêmur/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos
10.
Sci Rep ; 14(1): 10719, 2024 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-38729975

RESUMO

The shielding parameters can vary depending on the geometrical structure of the linear accelerators (LINAC), treatment techniques, and beam energies. Recently, the introduction of O-ring type linear accelerators is increasing. The objective of this study is to evaluate the shielding parameters of new type of linac using a dedicated program developed by us named ORSE (O-ring type Radiation therapy equipment Shielding Evaluation). The shielding evaluation was conducted for a total of four treatment rooms including Elekta Unity, Varian Halcyon, and Accuray Tomotherapy. The developed program possesses the capability to calculate transmitted dose, maximum treatable patient capacity, and shielding wall thickness based on patient data. The doses were measured for five days using glass dosimeters to compare with the results of program. The IMRT factors and use factors obtained from patient data showed differences of up to 65.0% and 33.8%, respectively, compared to safety management report. The shielding evaluation conducted in each treatment room showed that the transmitted dose at every location was below 1% of the dose limit. The results of program and measurements showed a maximum difference of 0.003 mSv/week in transmitted dose. The ORSE program allows for the shielding evaluation results to the clinical environment of each institution based on patient data.


Assuntos
Aceleradores de Partículas , Proteção Radiológica , Aceleradores de Partículas/instrumentação , Proteção Radiológica/instrumentação , Proteção Radiológica/métodos , Humanos , Radioterapia de Intensidade Modulada/métodos , Doses de Radiação
11.
J Imaging Inform Med ; 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38587767

RESUMO

De-identification of DICOM images is an essential component of medical image research. While many established methods exist for the safe removal of protected health information (PHI) in DICOM metadata, approaches for the removal of PHI "burned-in" to image pixel data are typically manual, and automated high-throughput approaches are not well validated. Emerging optical character recognition (OCR) models can potentially detect and remove PHI-bearing text from medical images but are very time-consuming to run on the high volume of images found in typical research studies. We present a data processing method that performs metadata de-identification for all images combined with a targeted approach to only apply OCR to images with a high likelihood of burned-in text. The method was validated on a dataset of 415,182 images across ten modalities representative of the de-identification requests submitted at our institution over a 20-year span. Of the 12,578 images in this dataset with burned-in text of any kind, only 10 passed undetected with the method. OCR was only required for 6050 images (1.5% of the dataset).

12.
Stud Health Technol Inform ; 313: 158-159, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38682523

RESUMO

BACKGROUND: Self-recorded EEG by patients at home might present a viable alternative to inpatient epilepsy evaluations. OBJECTIVES AND METHODS: We developed a novel telemonitoring system comprising seamlessly integrated hard- and software with automated AI-based EEG analysis. RESULTS: The first complete study participation results demonstrate feasibility and clinical utility. CONCLUSION: Our telemonitoring solution potentially improves treatment of patients with epilepsy and moreover might help to better distribute resources in the healthcare system.


Assuntos
Eletroencefalografia , Epilepsia , Estudos de Viabilidade , Telemedicina , Humanos , Eletroencefalografia/métodos , Epilepsia/diagnóstico , Telemedicina/métodos , Inteligência Artificial , Software , Masculino , Feminino
13.
Phys Med ; 121: 103369, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38669811

RESUMO

PURPOSE: In radiotherapy it is often necessary to transfer a patient's DICOM (Digital Imaging and COmmunications in Medicine) dataset from one system to another for re-treatment, plan-summation or registration purposes. The aim of the study is to evaluate effects of dataset transfer between treatment planning systems. MATERIALS AND METHODS: Twenty-five patients treated in a 0.35T MR-Linac (MRidian, ViewRay) for locally-advanced pancreatic cancer were enrolled. For each patient, a nominal dose distribution was optimized on the planning MRI. Each plan was daily re-optimized if needed to match the anatomy and exported from MRIdian-TPS (ViewRay Inc.) to Eclipse-TPS (Siemens-Varian). A comparison between the two TPSs was performed considering the PTV and OARs volumes (cc), as well as dose coverages and clinical constraints. RESULTS: From the twenty-five enrolled patients, 139 plans were included in the data comparison. The median values of percentage PTV volume variation are 10.8 % for each fraction, while percentage differences of PTV coverage have a mean value of -1.4 %. The median values of the percentage OARs volume variation are 16.0 %, 7.0 %, 10.4 % and 8.5 % for duodenum, stomach, small and large bowel, respectively. The percentage variations of the dose constraints are 41.0 %, 52.7 % and 49.8 % for duodenum, stomach and small bowel, respectively. CONCLUSIONS: This study has demonstrated a non-negligible variation in size and dosimetric parameters when datasets are transferred between TPSs. Such variations should be clinically considered. Investigations are focused on DICOM structure algorithm employed by the TPSs during the transfer to understand the cause of such variations.


Assuntos
Neoplasias Pancreáticas , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Neoplasias Pancreáticas/radioterapia , Neoplasias Pancreáticas/diagnóstico por imagem , Órgãos em Risco/efeitos da radiação , Imageamento por Ressonância Magnética
14.
Comput Methods Programs Biomed ; 248: 108113, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38479148

RESUMO

BACKGROUND AND OBJECTIVE: In recent years, Artificial Intelligence (AI) and in particular Deep Neural Networks (DNN) became a relevant research topic in biomedical image segmentation due to the availability of more and more data sets along with the establishment of well known competitions. Despite the popularity of DNN based segmentation on the research side, these techniques are almost unused in the daily clinical practice even if they could support effectively the physician during the diagnostic process. Apart from the issues related to the explainability of the predictions of a neural model, such systems are not integrated in the diagnostic workflow, and a standardization of their use is needed to achieve this goal. METHODS: This paper presents IODeep a new DICOM Information Object Definition (IOD) aimed at storing both the weights and the architecture of a DNN already trained on a particular image dataset that is labeled as regards the acquisition modality, the anatomical region, and the disease under investigation. RESULTS: The IOD architecture is presented along with a DNN selection algorithm from the PACS server based on the labels outlined above, and a simple PACS viewer purposely designed for demonstrating the effectiveness of the DICOM integration, while no modifications are required on the PACS server side. Also a service based architecture in support of the entire workflow has been implemented. CONCLUSION: IODeep ensures full integration of a trained AI model in a DICOM infrastructure, and it is also enables a scenario where a trained model can be either fine-tuned with hospital data or trained in a federated learning scheme shared by different hospitals. In this way AI models can be tailored to the real data produced by a Radiology ward thus improving the physician decision making process. Source code is freely available at https://github.com/CHILab1/IODeep.git.


Assuntos
Aprendizado Profundo , Sistemas de Informação em Radiologia , Inteligência Artificial , Computadores , Software
15.
Radiol Artif Intell ; 6(3): e230181, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38506618

RESUMO

Purpose To evaluate the effect of implementing two distinct commercially available deep learning reconstruction (DLR) algorithms on the efficiency of MRI examinations conducted in real clinical practice within an outpatient setting at a large, multicenter institution. Materials and Methods This retrospective study included 7346 examinations from 10 clinical MRI scanners analyzed during the pre- and postimplementation periods of DLR methods. Two different types of DLR methods, namely Digital Imaging and Communications in Medicine (DICOM)-based and k-space-based methods, were implemented in half of the scanners (three DICOM-based and two k-space-based), while the remaining five scanners had no DLR method implemented. Scan and room times of each examination type during the pre- and postimplementation periods were compared among the different DLR methods using the Wilcoxon test. Results The application of deep learning methods resulted in significant reductions in scan and room times for certain examination types. The DICOM-based method demonstrated up to a 53% reduction in scan times and a 41% reduction in room times for various study types. The k-space-based method demonstrated up to a 27% reduction in scan times but did not significantly reduce room times. Conclusion DLR methods were associated with reductions in scan and room times in a clinical setting, though the effects were heterogeneous depending on examination type. Thus, potential adopters should carefully evaluate their case mix to determine the impact of integrating these tools. Keywords: Deep Learning MRI Reconstruction, Reconstruction Algorithms, DICOM-based Reconstruction, k-Space-based Reconstruction © RSNA, 2024 See also the commentary by GharehMohammadi in this issue.


Assuntos
Aprendizado Profundo , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Feminino , Humanos , Masculino , Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Estudos Retrospectivos
16.
Heliyon ; 10(4): e26177, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38390159

RESUMO

As the human race has advanced, so too have the ailments that afflict it. Diseases such as pneumonia, once considered to be basic flu or allergies, have evolved into more severe forms, including SARs and COVID-19, presenting significant risks to people worldwide. In our study, we focused on categorizing pneumonia-related inflammation in chest X-rays (CXR) using a relatively small dataset. Our approach was to encompass a comprehensive view, addressing every potential area of inflammation in the CXR. We employed enhanced class activation maps (mCAM) to meet the clinical criteria for classification rationale. Our model incorporates capsule network clusters (CNsC), which aids in learning different aspects such as geometry, orientation, and position of the inflammation seen in the CXR. Our Capsule Network Clusters (CNsC) rapidly interpret various perspectives in a single CXR without needing image augmentation, a common necessity in existing detection models. This approach significantly cuts down on training and evaluation durations. We conducted thorough testing using the RSNA pneumonia dataset of CXR images, achieving accuracy and recall rates as high as 98.3% and 99.5% in our conclusive tests. Additionally, we observed encouraging outcomes when applying our trained model to standard X-ray images obtained from medical clinics.

17.
Stud Health Technol Inform ; 310: 1388-1389, 2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38269660

RESUMO

Medical images need annotations with high-level semantic descriptors, so that domain experts can search for the desired dataset among an enormous volume of visual media within a Medical Data Integration Center. This article introduces a processing pipeline for storing and annotating DICOM and PNG imaging data by applying Elasticsearch, S3 and Deep Learning technologies. The proposed method processes both DICOM and PNG images to generate annotations. These image annotations are indexed in Elasticsearch with the corresponding raw data paths, where they can be retrieved and analyzed.


Assuntos
Hospitais , Semântica , Tecnologia
18.
Stud Health Technol Inform ; 310: 1492-1494, 2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38269712

RESUMO

FHIR is a new standard that is rapidly being adopted in healthcare. We describe and implement a Radiology informatics platform (RIS) that is FHIR native and incorporates the ability to execute AI algorithms to aid with the interpretation of scans. Our design utilises the FHIR workflow pattern as an application programming interface with functionality provided by independent micro services thus granting flexibility and expandability.


Assuntos
Radiologia , Radiografia , Algoritmos , Instalações de Saúde , Informática
19.
Stud Health Technol Inform ; 310: 199-203, 2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38269793

RESUMO

Dermatology is one of the medical fields outside the radiology service that uses image acquisition and analysis in its daily medical practice, mostly through digital dermoscopy imaging modality. The acquisition, transfer, and storage of dermatology images has become an important issue to resolve. We aimed to describe our experience in integrating dermoscopic images into PACS using DICOM as a guide for the health informatics and dermatology community. During 2022 we integrated the video dermoscopy equipment through a strategic plan with an 8-step procedure. We used the DICOM standard with Modality Worklist and Storage commitment. Three systems were involved (video dermoscopy software, the EHR, and PACS). We identified critical steps and faced many challenges, such as the lack of a final model of DICOM standard for dermatology images.


Assuntos
Informática Médica , Software
20.
Phys Med ; 117: 103203, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38171219

RESUMO

Setup errors are an important factor in the dosimetric accuracy of radiotherapy delivery. In this study, we investigated how rotational setup errors influence the dose distribution in volumetric modulated arc therapy (VMAT) and tangential field-in-field (FiF) treatment of left-sided breast cancer with supraclavicular lymph node involvement in deep inspiration breath hold. Treatment planning computed tomography images and radiotherapy plans of 20 patients were collected retrospectively for the study. Rotational setup errors up to 3° were simulated by rotating the planning images, and the resulting dosimetric changes were calculated. With rotational setup errors up to 3°, the median decrease of V95% to clinical target volume was less than 0.8 percentage point in both VMAT and FiF plans. The dose distribution of the heart and left anterior descending artery was more stable with respect to rotations in VMAT plans compared to FiF plans. Correction of ≥1° setup errors is recommended due to increased doses to the heart and left anterior descending artery after 1° setup errors.


Assuntos
Neoplasias da Mama , Radioterapia de Intensidade Modulada , Neoplasias Unilaterais da Mama , Humanos , Feminino , Radioterapia de Intensidade Modulada/métodos , Neoplasias Unilaterais da Mama/diagnóstico por imagem , Neoplasias Unilaterais da Mama/radioterapia , Estudos Retrospectivos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Órgãos em Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...