Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Braz. dent. sci ; 27(1): 1-7, 2024. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1551411

RESUMO

Objective: The aim of the study was to report the aplicability of intraoral scanning while rubber dam isolation is in place. Material and Methods: Female patient, 50 years old, required restorative procedures on teeth 35 and 37. An intraoral scan was initially performed on both arches. Isolation was carried out from 33 to 37, tooth preparation and immediate dentin sealing were carried out. A new scan with the rubber dam in place was performed and a CAD/CAM lithium disilicate hybrid block was digitally designed, milled, crystallized and cemented under the tooth surface with the rubber dam still in position. After completing this stage, the rubber dam was removed, the occlusion was verified, presenting excellent aesthetic and functional results. Results: The absolute isolation process used in the present study works as an excellent device for gingival retraction. Conclusion: The absolute isolation can be recommended in clinical activities of intraoral scanning favoring the quality of the final result of treatments (AU)


Objetivo: O objetivo do estudo foi relatar a aplicabilidade do escaneamento intraoral sob isolamento absoluto. Material e Métodos: Paciente do sexo feminino, 50 anos, necessitou de procedimentos restauradores nos dentes 35 e 37. Uma varredura intraoral foi inicialmente realizada em ambos os arcos. O isolamento absoluto foi feito de 33 a 37, permitindo a realização do preparo dentário e selamento imediato da dentina. Um novo escaneamento com o dique de borracha colocado foi realizado e um bloco híbrido de dissilicato de lítio CAD/CAM foi projetado digitalmente, fresado, cristalizado e cimentado sob a superfície dentária ainda com o dique de borracha em posição. Após a finalização dessa etapa, o dique de borracha foi removido, a oclusão foi verificada apresentando ótimos resultados estéticos e funcionais. Resultados: O isolamento absoluto utilizado no presente estudo funciona como um excelente dispositivo para retração gengival. Conclusão: O isolamento absoluto pode ser recomendado em atividades clínicas de escaneamento intraoral favorecendo a qualidade do resultado final dos tratamentos (AU)


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , Diques de Borracha , Desenho Assistido por Computador , Encaixe de Precisão de Dentadura , Tecnologia Digital , Reabilitação Bucal
2.
Braz. dent. sci ; 26(3): 1-9, 2023. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1442902

RESUMO

Objective: This study aims to compare the strain induced in the supporting structures of unilateral mandibular removable partial denture frameworks retained by extra-coronal attachments fabricated with three different materials. Material and Methods: Three mandibular class II digitally designed and printed acrylic models with detachable abutments were used to fabricate three removable partial denture framework with extra coronal attachments from three different materials. A total of 33 models were prepared for strain testing (n=11). Models were divided into three groups according to framework's material: porcelain fused to cobalt chromium (PFM), polyetherketoneketone (PEKK) and polyetheretherketone (PEEK) group. Unilateral load of 60 N was applied in the three groups and strains were measured around the main abutment and saddle area using strain gauge. Results: Statistical analysis was performed using Shapiro-Wilk's test and by checking data distribution. Data were found to be non-parametric and were analysed using Kruskal-Wallis test followed by Dunn's post hoc test with Bonferroni correction. PFM group showed significantly the highest strain values around abutment, slot 1 (1mm distal to the socket of the last abutment) and slot 2 (1 cm away from slot 1) respectively (843.00±23.08, 91.00±6.52 and 1274.00±65.71) than the other tested groups (p<0.05) at same tested sites respectively followed by PEKK group (384.00±37.48, 81.00±2.24 and 135.00±0.00) and PEEK group (29.00±4.18, 63.00±4.47 and 52.00±5.70). Conclusions: PEEK and PEKK for partial denture framework with extra coronal attachments are adequate alternative to PFM due to their good mechanical response applying less strain on supportive structures in free-end cases. PEEK induces lower strain magnitude on the supporting structures when compared to PEKK. (AU)


Objetivo: Este estudo tem como objetivo comparar a tensão induzida nas estruturas de suporte de estruturas de próteses parciais removíveis mandibulares unilateraisretidas por encaixes extracoronários fabricados com três materiais diferentes. Material e Métodos: Três modelos mandibulares de classe II digitalmente projetados e impressos em acrílico com pilares destacáveis foram usados para fabricar três estruturas de próteses parciais removíveis com encaixes extracoronários de três materiais diferentes. Um total de 33 modelos foram preparados para testes de deformação (n=11). Os modelos foram divididos em três grupos de acordo com o material da estrutura: porcelana fundida com cobalto-cromo (PFM), poliétercetonacetona (PEKK) e polieteretercetona (PEEK). Carga unilateral de 60 N foi aplicada nos três grupos e as deformações foram medidas em torno do pilar principal e área de sela usando medido de tensão. Resultados: A análise estatística foi realizada por meio do teste de Shapiro-Wilk e com a verificação da distribuição dos dados. Os dados mostraram-se não paramétricos e foram analisados pelo teste de Kruskal-Wallis seguido pelo de Dunn com correção de Bonferroni. O grupo PFM mostrou significativamente os maiores valores de tensão ao redor do pilar, slot 1 (1mm distal do último pilar) e slot 2 (1 cm de distância do slot 1) respectivamente (843,00±23,08, 91,00±6,52 e 1274,00±65,71) do que os outros grupos testados (p<0,05) nos mesmos locais testados, respectivamente, seguido pelo grupo PEKK (384,00±37,48, 81,00±2,24 e 135,00±0,00) e grupo PEEK (29,00±4,18, 63,00±4,47 e 52,00±5,70). Conclusão: PEEK e PEKK para estrutura de prótese parcial com encaixes extracoronários são alternativas adequadas ao PFM devido à sua boa resposta mecânica aplicando menos tensão nas estruturas de suporte em casos de extremidade livre. O PEEK induz menor magnitude de deformação nas estruturas de suporte quando comparado ao PEKK (AU)


Assuntos
Prótese Parcial , Prótese Parcial Removível , Encaixe de Precisão de Dentadura
3.
BMC Oral Health ; 22(1): 227, 2022 06 09.
Artigo em Inglês | MEDLINE | ID: mdl-35681163

RESUMO

OBJECTIVES: The aim of the present study was to evaluate the retention and loss of retention after fatigue testing at different time intervals between two types of bar clip materials (digitally designed PEEK bar clip and regular Nylon bar clip). MATERIALS AND METHODS: An epoxy model was constructed for a completely edentulous mandible. Two implants were placed according to prosthetically driven implant placement by a computer-guided surgical stent. Bar clips were digitally designed, 3D printed, and pressed into Poly Ether Ether Ketone (PEEK). Pick up of PEEK and nylon clips was performed on the dentures fitting surface using self-cured acrylic resin. Each study group was subjected to an insertion and removal fatigue test simulating 3 years of patient usage. Retention values were recorded using the universal testing machine at initial retention and after 1, 2, and 3 years of simulated usage. For proper sample sizing, 24 models and dentures (12 for each group) were used. An independent sample t-test and repeated measures analysis of variance were used to compare the data. RESULTS: There were statistically significant differences in retention between the PEEK and nylon bar clips at the beginning of the experiment (p = 0.000*). But after 3 years of simulated use, there was no significant difference in retention between the test groups (p = 0.055, NS). After 3 years of simulated use, the retention of PEEK clips decreased by - 58.66% recording 17.37 ± 1.07 N, while the retention of nylon clip increased by + 2.99% recording 16.56 ± 0.88 N. CONCLUSION: The digitally designed PEEK clip showed comparable retention results to the nylon clip after 3 years of simulated use. CLINICAL RELEVANCE: Maintenance of bar attachment with PEEK clip offers a clinical solution after the wear of normal plastic clips, which is a cheap solution that is easily fabricated and picked up into the denture. Digital fabricated PEEK bar retentive inserts can be used in cases of bar attachment wear.


Assuntos
Implantes Dentários , Revestimento de Dentadura , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário , Retenção de Dentadura , Éteres , Humanos , Mandíbula/cirurgia , Nylons , Instrumentos Cirúrgicos
4.
Rev. Odontol. Araçatuba (Impr.) ; 43(1): 24-30, jan.-abr. 2022. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1361646

RESUMO

Introdução: As próteses parciais removíveis são alternativas amplamente utilizadas na reabilitação oral de pacientes parcialmente desdentados. Na atualidade os implantes dentais têm sido indicados para tratamento de pacientes edêntulos em associação com próteses parciais removíveis convencionais. Objetivo: Relatar um caso clínico utilizando uma prótese parcial removível convencional associada a implantes osseointegrados em paciente portador de Classe I de Kennedy. Relato de Caso: Paciente N.A.A.S., sexo feminino, 65 anos, procurou atendimento clínico no Instituto de Estudos da Saúde (IES) para reabilitação protética das arcadas dentais superior e inferior. A sua queixa principal era "dificuldade de mastigação". A paciente apresentava prótese total removível insatisfatória na maxila e não utilizava nenhum tipo de prótese dentária na mandíbula, que se apresentava parcialmente edêntula. O tratamento realizado foi a confecção de uma prótese total na arcada superior. Na arcada inferior foram inseridos dois implantes de hexágono externo nas regiões correspondentes às áreas dos dentes 34 e 44, após quatro meses a prótese parcial removível convencional foi confeccionada e incorporada aos implantes osseointegrados utilizando o sistema de retenção do tipo attachments Equator. Conclusão: Os resultados revelaram que a técnica de associação da prótese parcial removível convencional aos implantes osseointegrados demonstrou ser uma opção viável de tratamento com capacidade de devolver a função, a estética e manter a integridade dos dentes e tecidos periodontais(AU)


Introduction: Removable partial dentures are alternatives widely used in the oral rehabilitation of partially edentulous patients. Currently, dental implants have been indicated for the treatment of edentulous patients in association with conventional removable partial dentures. Objective: To report a clinical case using a conventional removable partial denture associated with osseointegrated implants in a patient with Kennedy Class I. Case Report: Patient N.A.A.S., female, 65 years old, sought clinical care at the Institute of Health Studies (HEI) for prosthetic rehabilitation of the upper and lower dental arches. His main complaint was "chewing difficulty". The patient had unsatisfactory removable total prosthesis in the maxilla and did not use any type of dental prosthesis in the mandible, which was partially edentulous. The treatment performed was the manufacture of a total prosthesis in the upper arch. In the lower arch, two external hexagon implants were inserted in the regions corresponding to the tooth areas 34 and 44, after four months the conventional removable partial denture was made and incorporated into the osseointegrated implants using the equator attachments retention system. Conclusion: The results revealed that the technique of associating conventional removable partial dentures with osseointegrated implants proved to be a viable treatment option with the ability to restore function, aesthetics and maintain the integrity of teeth and periodontal tissues(AU)


Assuntos
Humanos , Feminino , Idoso , Implantação Dentária Endóssea , Prótese Parcial Removível , Implantes Dentários , Planejamento de Prótese Dentária , Estética Dentária , Prótese Ancorada no Osso
5.
J Evid Based Dent Pract ; 21(4): 101622, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34922713

RESUMO

BACKGROUND: A shortened dental arch (SDA) is an established treatment concept for patients with missing molars. However, little is known regarding long-term course of oral health-related quality of life (OHRQoL) in patients with SDA and the benefits from replacement of missing molars. OBJECTIVE: Purpose of this multi-center randomized clinical trial was to assess OHRQoL over a period of 15 years in patients with molar replacement by a removable partial denture (RPD) compared to patients with a restored SDA without molar replacement. METHODS: Patients at least 35 years of age with all molars missing in 1 jaw and at least the canine and one premolar present on each side were included. Patients received either a precision attachment-retained, RPD for replacement of missing molars (n = 79), or the dental arch ended with the second premolar (SDA) that had to be present or replaced by a cantilever fixed dental prosthesis (n = 71). Follow-up examinations continued for 15 years. OHRQoL was assessed with the 49-item Oral Health Impact Profile (OHIP). OHIP summary and dimension scores were longitudinally modeled in the statistical analyses to assess course of OHRQoL over time applying an intention-to-treat approach. In addition, scores for the OHRQoL dimensions Oral Function, Orofacial Pain, Orofacial Appearance, and Psychosocial Impact were analyzed. RESULTS: After an initial improvement in OHRQoL indicated by a mean decrease of 20.0 OHIP points with an effect size of 0.61 in the entire study population, OHRQoL stayed relatively constant over the entire follow-up period. Assuming a constant time and treatment effects over the study period, OHRQoL did not differ statistically significant between the 2 treatments (0.4 OHIP points; 95%-CI: 7.1 - 6.2). OHRQoL after treatment did not change notably over 15 years and was statistically nonsignificant as well (P = .872). Similar findings were observed in all 4 OHRQoL dimensions. CONCLUSIONS: In patients, missing all molars in one jaw OHRQoL improved providing RPD or restoring SDA to a clinically relevant degree. Treatment-related improvement remained mostly stable over a period of at least 15 years. Therefore, patients can be informed that both treatment concepts are equivalent concerning long-term OHRQoL. Accordingly, patients' preferences regarding treatment options should be granted priority in treatment decision making with the SDA treatment option being the default.


Assuntos
Prótese Parcial Removível , Qualidade de Vida , Arco Dental , Humanos , Saúde Bucal , Inquéritos e Questionários
6.
Saudi Dent J ; 33(6): 299-307, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34434031

RESUMO

OBJECTIVE: This review is to compare patient-satisfaction with ball-type overdenture attachment systems with others attachment systems. MATERIAL AND METHODS: This study was registered in PROSPERO (CRD42018097234) and adheres the PRISMA guidelines. Electronic searches on PubMed/MEDLINE, Scopus, Cochrane, and Web of Science databases for published articles were performed before October 2020. The PICO question was: "Do patients with a ball-type overdenture retention system have greater satisfaction, when compared to other attachment systems?" The evaluation of risk of bias was performed using the Cochrane risk of bias tool. RESULTS: After searching the databases, seven articles were selected out of a total of 2583. A total of 312 implants were placed in 139 patients, with a mean age of 65.9 years. The risk of bias in the included studies varied according to the different domains in a risk of uncertain bias or low bias risk. No difference was found between the ball attachment systems and the others systems, with respect to patient-satisfaction. The meta-analysis revealed no statistically significant difference between the ball systems and another systems (P = 0.11; MD: 10.90; 95% CI: -2.55 to 24.35). CONCLUSIONS: Regarding patient general satisfaction, it was not possible to determine differences between the ball system and another types of attachment system for overdenture. The ball-type system was statistically superior only to the magnet system.

7.
Materials (Basel) ; 12(22)2019 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-31744164

RESUMO

The purpose of this study was to evaluate the change in the retentive forces of four different titanium-based implant attachment systems during the simulation of insert-removal cycles in an artificial oral environment. Five types of titanium-based dental implant attachment systems (Locator, Kerator, O-ring, EZ-Lock, and Magnetic) were studied (n = 10). The specimens underwent insert-removal cycles in artificial saliva, and the retentive force was measured following 0, 750, 1500, and 2250 cycles. Significant retention loss was observed in all attachment systems, except the magnetic attachments, upon completion of 2250 insertion and removal cycles, compared to the initial retentive force (p < 0.05). A comparison of the initial retentive forces revealed the highest value for Locator, followed by the Kerator, O-ring, EZ-Lock, and Magnetic attachments. Furthermore, Kerator demonstrated the highest retentive loss, followed by Locator, O-ring, EZ-Lock, and Magnetic attachments after 2250 cycles (p < 0.05). In addition, the Locator and Kerator systems revealed significant decrease in retentive forces at all measurement points (p < 0.05). The retention force according to the insert-removal cycles were significantly different according to the types of dental implant attachment systems.

8.
Zhonghua Kou Qiang Yi Xue Za Zhi ; 54(1): 41-45, 2019 Jan 09.
Artigo em Chinês | MEDLINE | ID: mdl-30630258

RESUMO

Objective: To compare the biomechanical characteristics of four-implants mandibular overdentures supported by Locator attachment or bar-clip attachment under different mechanical loads using three-dimensional finite element analysis method. Methods: Two different models of four-implants supported mandibular overdentures using Locator attachment and bar-clip attachment (hereinafter called Locator model and bar-clip model) were established. Each model was subjected to five different mechanical loading conditions: 100 N vertical loading in central incisor (vertical load of incisor), 100 N vertical loading or oblique loading in canine (vertical or oblique loads of canines), 100 N vertical or oblique loading in mandibular first molar (vertical or oblique loads of mandibular first molar). The stress distributions in implants, peri-implant bone and mucosa were recorded under the above five conditions to evaluate the effects of different attachments on the biomechanical properties of implant-supported mandibular overdentures. Results: Regardless of loading conditions and types of attachments, the stress concentration in implants were located at the neck of implants, and the stress concentration in peri-implant bone was located in the cortical bone. The stress values in mucosa were always much smaller than those in implants and cortical bone. Regardless of loading positions (on canine or on mandibular first molar), the maximum stress at the bone interface around the implant under lateral loading was much higher than that under vertical loading. Under various loading conditions, the stress in implants and cortical bone of the Locator model (the highest von Mise stress value was respectively 79.5 and 22.3 MPa) were lower than that of bar-clip model (the highest von Mise stress value was 110.3 and 28.7 MPa respectively) while the maximum compressive stress in mucosa (0.198 MPa) in Locator model was slightly higher than that in the bar-clip model (0.137 MPa). Conclusions: In clinical practice, the lateral force applied to the implant-retained overdenture should be minimized to avoid complications caused by pathological loads. Under the same loading condition, the stress distributions in overdenture using Locator attachment are more dispersed, which is more conducive to long-term stability of implants.


Assuntos
Prótese Dentária Fixada por Implante , Revestimento de Dentadura , Análise de Elementos Finitos , Implantes Dentários , Análise do Estresse Dentário , Retenção de Dentadura , Mandíbula , Estresse Mecânico
9.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-804587

RESUMO

Objective@#To compare the biomechanical characteristics of four-implants mandibular overdentures supported by Locator attachment or bar-clip attachment under different mechanical loads using three-dimensional finite element analysis method.@*Methods@#Two different models of four-implants supported mandibular overdentures using Locator attachment and bar-clip attachment (hereinafter called Locator model and bar-clip model) were established. Each model was subjected to five different mechanical loading conditions: 100 N vertical loading in central incisor (vertical load of incisor), 100 N vertical loading or oblique loading in canine (vertical or oblique loads of canines), 100 N vertical or oblique loading in mandibular first molar (vertical or oblique loads of mandibular first molar). The stress distributions in implants, peri-implant bone and mucosa were recorded under the above five conditions to evaluate the effects of different attachments on the biomechanical properties of implant-supported mandibular overdentures.@*Results@#Regardless of loading conditions and types of attachments, the stress concentration in implants were located at the neck of implants, and the stress concentration in peri-implant bone was located in the cortical bone. The stress values in mucosa were always much smaller than those in implants and cortical bone. Regardless of loading positions (on canine or on mandibular first molar), the maximum stress at the bone interface around the implant under lateral loading was much higher than that under vertical loading. Under various loading conditions, the stress in implants and cortical bone of the Locator model (the highest von Mise stress value was respectively 79.5 and 22.3 MPa) were lower than that of bar-clip model (the highest von Mise stress value was 110.3 and 28.7 MPa respectively) while the maximum compressive stress in mucosa (0.198 MPa) in Locator model was slightly higher than that in the bar-clip model (0.137 MPa).@*Conclusions@#In clinical practice, the lateral force applied to the implant-retained overdenture should be minimized to avoid complications caused by pathological loads. Under the same loading condition, the stress distributions in overdenture using Locator attachment are more dispersed, which is more conducive to long-term stability of implants.

10.
Braz. dent. j ; 29(6): 576-582, Nov.-Dec. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-974198

RESUMO

Abstract Several attachment systems for mandibular implant-supported overdentures are currently available and studies are required to understand their mechanical properties. The objective of this study was to evaluate the retention force and wear characteristics of three attachment systems in a simulation of the cyclic dislodging of implant-supported overdentures. Thirty samples were fabricated and divided into 3 groups: 1-O-ring; 2-Mini Ball; and 3-Equator. A mechanical fatigue test was applied to the specimens using a servo-hydraulic universal testing machine performing 5500 insertion/removal cycles (f=0.8 Hz), immersed in artificial saliva. Retention force values ​​were obtained before and after 1500, 3000, and 5500 cycles using a speed of 1 mm/min and a load cell of 1 kN. One specimen from each group was randomly selected and analyzed by scanning electron microscopy. Two-way repeated measures ANOVA and the Bonferroni post hoc test were used for statistical analyses (α=0.05). The O-ring system remained stable during all periods tested and exhibited significantly lower retention force values than the Mini Ball and Equator systems. The Mini Ball system exhibited a significant increase in retention force after the mechanical test (baseline=21.04±3.29N; 5500 cycles=24.01±3.30N).The Equator system exhibited a significant decrease in retention force after each period tested, but the values were higher than the other systems. The type of attachment was found to influence retention force in different ways after mechanical tests. The Equator system exhibited the highest retention force values. The Mini Ball and Equator matrices produced deformation and wear on the surfaces without breakage of the polyamide rings.


Resumo Vários sistemas de encaixe para sobredentaduras mandibulares implantossuportadas estão atualmente disponíveis e estudos são necessários para entender as suas propriedades mecânicas. O objetivo deste estudo foi avaliar a força de retenção e as características de desgaste de três sistemas de encaixe por meio de uma simulação de deslocamento cíclico de sobredentaduras implantossuportadas. Trinta amostras foram fabricadas e divididas em 3 grupos: 1-O-ring; 2-Mini Ball; e 3-Equador. Um teste de fadiga mecânica foi aplicado aos espécimes utilizando uma máquina de teste universal servo-hidráulica com 5500 ciclos de inserção/remoção (f = 0,8 Hz), imersos em saliva artificial. Os valores da força de retenção foram obtidos antes e após 1500, 3000 e 5500 ciclos utilizando uma velocidade de 1 mm/min e uma célula de carga de 1 kN. Um espécime de cada grupo foi selecionado aleatoriamente e analisado por microscopia eletrônica de varredura. O teste de Análise de Variância a dois fatores para medidas repetidas e o teste de comparações múltiplas de Bonferroni foram utilizados para análises estatísticas (α = 0,05). O sistema de O-ring permaneceu estável durante todos os períodos testados e apresentou valores de força de retenção significativamente menores do que os sistemas Mini Ball e Equator. O sistema Mini Ball apresentou um aumento significativo na força de retenção após o teste mecânico (controle = 21,04 ± 3,29N; 5500 ciclos = 24,01 ± 3,30N). O sistema Equator apresentou uma diminuição significativa na força de retenção após cada período testado, mas os valores eram maiores do que os outros sistemas. O tipo de sistema de encaixe influenciou na força de retenção de diferentes maneiras após testes mecânicos. O sistema do Equador exibiu os maiores valores de força de retenção. As matrizes dos sistemas Mini Ball e Equator produziram deformação e desgaste nas superfícies sem ruptura dos anéis de poliamida.


Assuntos
Humanos , Prótese Dentária Fixada por Implante , Revestimento de Dentadura , Encaixe de Precisão de Dentadura , Saliva Artificial , Resistência à Tração , Teste de Materiais , Análise do Estresse Dentário
11.
Gen Dent ; 66(6): 71-75, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30444711

RESUMO

Prosthodontic treatment for edentulous maxillae with severe bone loss is a challenge to clinicians. Although implant-supported, fixed maxillary complete dentures are increasingly common, they are not always able to provide adequate lip support without a buccal overextension in patients with bone loss. The overextended buccal flange makes it difficult for patients to clean under the prosthesis. This case report describes rehabilitation of an atrophic maxilla through an implant-supported double-bar overdenture designed to resolve difficulties in oral hygiene maintenance that were caused by the buccal overextension of the prosthetic flange in a previous implant-supported fixed complete denture. In addition to reestablishing lip support, overdentures with a double-bar system provide retention and stability, because the prosthesis is only removed for cleaning by the patient with the help of a specific key. Implant-supported double-bar overdentures represent a viable and versatile option for rehabilitation of atrophic maxillae.


Assuntos
Perda do Osso Alveolar/cirurgia , Prótese Dentária Fixada por Implante , Revestimento de Dentadura , Prótese Dentária Fixada por Implante/microbiologia , Planejamento de Dentadura , Feminino , Humanos , Lábio , Maxila , Pessoa de Meia-Idade
12.
J Oral Rehabil ; 45(8): 647-656, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29761853

RESUMO

Splinted and unsplinted overdenture attachment systems have unique advantages and disadvantages. The aim of the present systematic review was to determine the influence of splinted and unsplinted overdenture attachment systems on the marginal bone loss, prosthetic complications and implant survival rate. PubMed/MEDLINE, Scopus and Cochrane databases were searched for articles published up to October 2017, using the following search terms: "overdenture AND attachment OR overdenture AND bar OR overdenture splinted." The PICO question "Do splinted overdenture attachment systems promote better clinical results in comparison to unsplinted systems?" was evaluated. Eligible studies included randomized controlled clinical trials, prospective studies with at least 10 participants and a minimum follow-up of 6 months, and studies published in English that compared splinted and unsplinted attachment systems within the same study. The 95% confidence interval (CI) was considered for all outcomes analysed. After completion of the different steps in the article selection process, nine articles were included in the qualitative and quantitative analyses. A total of 984 implants were placed in 380 patients (mean age: 62.8 years). The meta-analysis demonstrated no statistically significant differences between splinted and unsplinted attachment systems with regard to marginal bone loss (P = .39; MD: -0.11; 95% CI: -0.37 to 0.14), complications (P = .31; RR: 1.26; CI: 0.80-1.99) and implant survival rate (P = .14; RR: 0.37% CI: 0.10-1.36). In addition, splinted and unsplinted overdenture attachment systems achieved similar results with regard to marginal bone loss, prosthetic complications and implant survival rate.


Assuntos
Perda do Osso Alveolar/fisiopatologia , Prótese Dentária Fixada por Implante , Retenção de Dentadura/instrumentação , Osseointegração/fisiologia , Perda da Inserção Periodontal/fisiopatologia , Implantes Dentários , Planejamento de Dentadura , Encaixe de Precisão de Dentadura , Revestimento de Dentadura , Humanos , Perda da Inserção Periodontal/diagnóstico
13.
Prosthes. Esthet. Sci ; 7(27): 73-77, abr.-jun. 2018.
Artigo em Português | BBO - Odontologia | ID: biblio-906959

RESUMO

A reabilitação oral de pacientes parcialmente dentados é versátil e pode ser realizada a partir de várias opções de tratamentos. Os sistemas de encaixes em Próteses Parciais Removíveis (PPR) são opções clínicas disponíveis idealizadas a fim de melhorar as limitações estéticas e funcionais das PPRs. O objetivo deste estudo foi descrever sobre os sistemas de encaixes em prótese parcial removível, elencando suas principais indicações, contraindicações, vantagens e desvantagens a partir de uma revisão de literatura. A revisão foi realizada utilizando-se a base de dados PubMed, SciELO e Lilacs para identificar todos os artigos publicados em português, inglês e espanhol acerca do tema abordado, sendo selecionados aqueles relatos de caso único ou série de casos. As palavras-chave utilizadas foram: "Prótese parcial removível", "Encaixe de precisão de dentadura", "Prótese dentária". A partir das indicações, contraindicações, vantagens e desvantagens do tratamento reabilitador com próteses parciais com sistemas de encaixe, entende-se que com um planejamento clínico e laboratorial adequado, essa opção de tratamento pode proporcionar um excelente resultado para os pacientes parcialmente edêntulos.


Oral rehabilitation for partially edentulous patient is carried out on various treatment options. The attachment systems (clasps) for Removable Partial Dentures (RPD) are available clinical choices idealized to improve the aesthetic and functional limitations of the RPDs. This study aimed at describing the attachment systems of removable partial denture, highlighting their main indications, contraindications, advantages and disadvantages from a literature review. The literature review was carried out using the PubMed, SciELO and Lilacs database to identify all the articles published in Portuguese, English and Spanish languages about the topic, selecting single case and case series report. The key words used were: "Denture, partial, removable", "Denture Precision Attachment", "Dental Prosthesis." Considering the indications, contraindications, advantages and disadvantages of the rehabilitation treatment with partial dentures with attachment system, when performed following an adequate clinical and laboratory planning, this treatment option can provide an excellent result for partially edentulous patient.


Assuntos
Prótese Dentária , Ajuste de Prótese , Prótese Parcial Removível , Encaixe de Precisão de Dentadura
14.
Prosthes. Lab. Sci ; 6(24): 127-135, jul.-set. 2017. ilus
Artigo em Português | BBO - Odontologia | ID: biblio-877933

RESUMO

Na Odontologia a interação interdisciplinar é a chave para melhorar os resultados estéticos e funcionais. Quando alterações dentais e periodontais afetam a harmonia do sorriso, existe a necessidade de agregar procedimentos multidisciplinares para alcançar a estética desejada. Este trabalho apresentou como objetivo relatar um caso clínico de restabelecimento da harmonia do sorriso de uma paciente que apresentava anteriormente uma coroa cerâmica com retentor intra-radicular metálico fundido e constante inflamação na gengiva marginal no elemento dental 21. O tratamento foi feito por meio da associação da extrusão ortodôntica, cirurgia periodontal de recuperação de espaço biológico e reabilitação protética por meio de coroa metal-free, bem como os resultados obtidos com essa modalidade de tratamento. Conclui-se então que foi possível observar sucesso no tratamento executado pela equipe multidisciplinar, devolvendo a estética e a função do elemento dentário. Dessa forma, ressalta-se a importância da interdisciplinaridade na odontologia que, neste caso, vai desde a avaliação estética do caso à necessidade de manter a saúde periodontal para a instalação da reabilitação definitiva. É de relevância conhecer e respeitar as distâncias biológicas do periodonto, bem como o correto diagnóstico e plano de tratamento quando da sua violação.


In dentistry interdisciplinary interaction is the key to improve the aesthetic and functional results. When dental and periodontal changes affect smile harmony, it is necessary to add multidisciplinary procedures to achieve the desired aesthetic. This work had the objective to report a clinical case of smile harmony restoration of a patient that previously had a ceramic crown with metal intraradicular cast retainer and constant gingival margin inflammation in dental element 21. The treatment was performed through association of orthodontic extrusion, periodontal surgery for biological space recovery and prosthetic rehabilitation by means of metal-free crown, as well as the results obtained with this treatment modality. It was concluded that it was possible to observe that treatment performed by the multidisciplinary team was successful, returning aesthetics and function to the tooth. So it emphasizes the importance of interdisciplinarity in dentistry that in this case, was from the aesthetic evaluation of the case until the need to maintain periodontal health for the installation of permanent rehabilitation. It is important to know and respect the biological periodontium distances as well as the correct diagnosis and treatment plan when its violated.


Assuntos
Humanos , Feminino , Adulto , Cerâmica , Coroas , Prótese Parcial Fixa , Gengivectomia , Lítio , Extrusão Ortodôntica
15.
J Adv Prosthodont ; 8(5): 411-416, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27826392

RESUMO

Patients who underwent resection of maxilla due to benign or malignant tumor, or accident will have defect in palatal area. They get retention, support and stability from remaining tissues which are hardly optimal. The advantage of swing-lock attachment design is having multiple contacts on labial and lingual side of the abutment teeth by retentive strut and palatal bracing component. Because the force is distributed equally to abutment teeth, abutment teeth of poor prognosis can be benefited from it. It is also more advantageous to cover soft tissue defects which are hard to reach with conventional prosthesis. A 56-year-old female patient who had undergone a maxillectomy due to malignant melanoma complaining of loose and unstable surgical obturator. Surveyed crowns were placed on #12, 26, and 27. Teeth #11, 21, 22, and 23 had lingual rest seat and #24 had mesial rest seat to improve stability and support of the obturator. This clinical report presents the prosthetic management of a patient treated with obturator on the maxilla using swing-lock attachment to the remaining teeth.

16.
Rev. odontol. Univ. Cid. São Paulo (Online) ; 28(1): 43-49, jan.-abr. 2016.
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-2636

RESUMO

As próteses totais convencionais inferiores são as mais difíceis de adaptar, devido à perda óssea ser maior e consequentemente à baixa estabilidade e pouca retenção. Entretanto, com o aparecimento dos implantes osse-ointegráveis surgiram os tratamentos com próteses do tipo overdenture, as quais oferecem melhor estabilidade e retenção. O objetivo deste trabalho foi comparar os três principais tipos de sistemas de retenção para a pró¬tese overdenture encontrada na literatura. Para isso, foram realizadas pesquisas com os termos "overdenture"; "attachment", "implant-supported", "dental prosthesis", "denture" e "oral rehabilitation" nas bases de dados PubMed, Science Direct e Scielo. Os sistemas barra-clipe e esférico apresentaram semelhanças estatísticas quanto à retenção e estabilidade. Já o sistema magnético apresentou pouca retenção e baixa estabilidade


The conventional lower total prosthesis is the most difficult dental prosthesis to adapt in the patients mouth, due to bone loss be greater in this region, which consequently decreases stability and retention of the prosthe¬sis. However, the appearance of osseointegrated implants gave rise to treatments with overdenture prostheses, which offer better stability and retention to the prostheses. The aim of this study was to compare the three main types of overdenture prosthesis restraint systems found in the literature. For this research, we used the terms: "overdenture"; "attachment", "implant-supported", "dental prosthesis", "denture" and "oral rehabilitation" in the databases of PubMed, Science Direct and Scielo. The clip bar and spherical systems presented statistical similarities regarding retention and stability. Already, the magnetic system presented little retention and low stability


Assuntos
Implante de Prótese Mandibular , Implantação de Prótese , Revestimento de Dentadura , Encaixe de Precisão de Dentadura , Reabilitação Bucal
17.
Prosthes. Lab. Sci ; 5(20): 85-89, jul.-set. 2016. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-859398

RESUMO

Os medicamentos antirreabsortivos, como os bisfosfonatos, são usados para tratamento de diversas patologias ósseas. Uma de suas complicações relacionadas à Odontologia é a osteonecrose dos maxilares e o tratamento conservador deve ser a primeira opção. Em casos de pacientes total ou parcialmente edêntulos que fazem uso de medicamentos desta classe, as próteses são mais convenientes para reabilitação. Sabemos que estética é um dos fatores de maior relevância para o paciente, o que torna cada vez mais difícil a aceitação de próteses que contenham grampos, como as próteses parciais removíveis e que, por mais criterioso que seja o planejamento, a associação de suporte, retenção, estabilidade e estética sempre deixa a desejar. O objetivo deste relato de caso foi mostrar uma reabilitação sem a instalação de implantes, a prótese parcial removível, com encaixe de precisão em paciente que faz uso do medicamento e que prezava por uma estética satisfatória.


Antiresorptive drugs such as bisphosphonates are used to treat several bone diseases. Their complication related to Dentistry is osteonecrosis of the jaw and a conservative treatment should be the first option. In cases of total or partially edentulous patients that make use of this class of medication prostheses are more convenient for rehabilitation. It is known that aesthetics is one of the most important factors for the patient and this hampers the acceptance of prostheses with staples such as removable partial dentures. And it doesn't matter how judicious the planning the association of retention, support, stability and aesthetics always falls short. The objective of this report was to present rehabilitation without implant installation using removable partial denture with precision fit in a bisphosphonates who wished a satisfactory aesthetic outcome.


Assuntos
Humanos , Feminino , Idoso , Encaixe de Precisão de Dentadura , Prótese Parcial Removível , Difosfonatos , Estética Dentária , Osteonecrose
18.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-180730

RESUMO

Patients who underwent resection of maxilla due to benign or malignant tumor, or accident will have defect in palatal area. They get retention, support and stability from remaining tissues which are hardly optimal. The advantage of swing-lock attachment design is having multiple contacts on labial and lingual side of the abutment teeth by retentive strut and palatal bracing component. Because the force is distributed equally to abutment teeth, abutment teeth of poor prognosis can be benefited from it. It is also more advantageous to cover soft tissue defects which are hard to reach with conventional prosthesis. A 56-year-old female patient who had undergone a maxillectomy due to malignant melanoma complaining of loose and unstable surgical obturator. Surveyed crowns were placed on #12, 26, and 27. Teeth #11, 21, 22, and 23 had lingual rest seat and #24 had mesial rest seat to improve stability and support of the obturator. This clinical report presents the prosthetic management of a patient treated with obturator on the maxilla using swing-lock attachment to the remaining teeth.


Assuntos
Feminino , Humanos , Pessoa de Meia-Idade , Braquetes , Coroas , Encaixe de Precisão de Dentadura , Maxila , Melanoma , Obturadores Palatinos , Prognóstico , Próteses e Implantes , Dente
19.
Acta Stomatol Croat ; 49(2): 145-50, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27688397

RESUMO

This clinical report describes a fixed maxillary telescopic dental prosthesis (FTDP) employing milled base metal copings and a metal superstructure veneered with composite resin, for the restoration in a periodontally compromised patient with uncontrolled diabetes. The telescopic prosthesis framework design incorporated occlusal rest seats in key positions along the arch in case of future posterior tooth loss, in order to be converted to fixed - removable combination prosthesis. The mandible was restored with a conventional fixed ceramo-metal dental prosthesis.

20.
Bauru; s.n; 2015. 67 p. ilus, tab.
Tese em Português | BBO - Odontologia | ID: biblio-867414

RESUMO

Soluções higienizadoras podem acarretar efeitos prejudiciais para as próteses, como deterioração da base da prótese e pigmentação. Porém, pouco se conhece sobre os efeitos destas na vida útil dos sistemas de retenção de uma overdenture. Deste modo, este estudo buscou avaliar se imersões diárias em clorexidina 2%, hipoclorito de sódio 1%, Corega® Tabs e água (controle) poderia acelerar a perda de retenção em attachments do tipo o´ring (S.I.N sistema de implantes®). Foram confeccionados 40 corpos de prova contendo cápsulas com anéis de borracha, simulando uma overdenture, e apenas 01 contendo o implante com o pilar o´ring. Eles foram separados em quatro grupos (n=10) e simulados noventa dias de imersões. Após, foram realizados testes de resistência à tração em uma máquina de ensaios mecânicos (MTS 810), antes e após a ciclagem com 270 ciclos, equivalentes a remoção e inserção da prótese três vezes ao dia, durante um período de três meses. Os resultados foram avaliados estatisticamente através dos testes ANOVA a dois critérios e do teste de Tukey (p≤0.05). Os valores médios (Newton) encontrados antes e após a imersão foram, respectivamente: Água - 9,482 / 6,081; Clorexidina - 9,972 / 7,390; Hipoclorito: 6,954 / 6,265 e Corega® Tabs: 12,464 / 11,121. Entre os grupos Clorexidina, Hipoclorito de sódio e Água não houve diferenças significativas. Houve diferenças estatisticamente significativas entre o grupo Corega® Tabs e os grupos controle e Hipoclorito de sódio, mas não com a Clorexidina. Assim, pôde-se concluir que soluções higienizadoras tiveram efeitos significativos na capacidade de retenção dos o´rings após o período simulado de três meses de imersão.


Denture cleansers can cause adverse effects on the prostheses, as deterioration of the denture base and pigmentation. However, little is known about its impacts on the life of an overdenture retention systems. Thus, this study sought to evaluate whether daily immersion in chlorhexidine 2%, sodium hypochlorite 1%, Corega® Tabs and water (control) would increase the retention loss in the O-ring type attachments (SIN implantes® system). Forty specimens containing capsules were made with rubber rings, simulating an overdenture, and only one containing the implant with the O-ring abutment. They were divided into four groups (n = 10) and ninety days in immersion were simulated, thereafter, conducted tensile strength tests on a testing machine (MTS - 810) before and after cycling of 270 cycles, equivalent to removal and insertion of the prosthesis three times a day for a period of three months. The results were statistically evaluated by the ANOVA two criteria and the Tukey test (p≤0.05). The mean values (Newton) found before and after immersion were: Water - 9,482 / 6,081; Chlorhexidine - 9,972 / 7,390; Hypochlorite: 6,954 / 6,265 and Corega® Tabs: 12.464 / 11.121. Among the groups chlorhexidine, sodium hypochlorite and water there were no significant differences. There were statistically significant differences between the group Corega® Tabs and controls and sodium hypochlorite groups, but not with the chlorhexidine. Thus, it concluded that denture cleansers had significant effects on retention capacity of orings after the simulated period of three months of immersion.


Assuntos
Clorexidina/química , Prótese Dentária , Desinfetantes/química , Higienizadores de Dentadura/química , Hipoclorito de Sódio/química , Análise de Variância , Borracha/química , Imersão , Teste de Materiais , Resistência à Tração , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...