Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Ci. Anim. bras. ; 16(3): 419-427, Jul-Set. 2015. ilus, tab
Artigo em Inglês | VETINDEX | ID: vti-12979

RESUMO

Ultrasonography is an accurate pregnancy diagnostic method, besides being completely innocuous for female and fetuses evaluation. The objective of this paper was to determine the reference values for gestational echo biometry of different breeds of bitches. A total of 25 multiparous females were included in the experiment, five English Bulldog bitches, five Pugs and 15 Shih Tzu, weighing 4-25 kg and aged 4-6 years. The echo biometric assessments were performed during the 2nd, 5th, 6th, 7th and 8th weeks of pregnancy, including gestational vesicle diameter, femur length, placenta thickness, parietal diameter, liver, heart and abdominal diameter and area. Early echo biometric study started at the second week of gestation. Measurements like fetal heart and liver diameter and area are ??still poorly studied, but can provide useful information for early detection of congenital anomalies that may reduce the viability of pregnancy. The significant results (P 0.001) obtained for biometrics (P 0.001) of the parietal (r2 = 81%) and abdominal diameter (r2 = 86%), abdominal area (r2 = 80%), femur length (r2 = 84%), cardiac length (r2 = 79%), width (r2 = 79%), area (r2 = 82%) and volume (r2 = 72%) and liver area (r2 = 71%) in brachycephalic conceptus may help to assess the development of fetuses, complementing the conventional gestational ultrasound of bitches and become a model for the study in other breeds of dogs and alternative animal species.(AU)


O exame ultrassonográfico é um meio de diagnóstico preciso para avaliação da gestação, além de ser totalmente inócuo para fêmea e fetos. Objetivou-se com este estudo determinar os valores de referência para a ecobiometria gestacional em cadelas de diferentes raças. Foram utilizadas 25 fêmeas multíparas, sendo cinco cadelas Bulldog inglês, cinco Pugs e 15 Shih Tzu, pesando de 4 a 25 kg e com idade entre 4 a 6 anos. As avaliações ecobiométricas como diâmetro da vesícula gestacional, comprimento femoral, espessura da placenta, diâmetro parietal, diâmetro e área abdominal, hepática e cardíaca foram realizadas durante as 2ª, 5ª, 6ª, 7ª e 8ª semanas gestacionais das cadelas. O estudo ecobiométrico em cadelas gestantes foi precocemente iniciado a partir da segunda semana gestacional. Mensurações pouco estudadas como o diâmetro e área hepática e valores ecobiométricos do coração fetal, podem fornecer informações úteis para a detecção precoce de anomalias congênitas que podem comprometer a viabilidade gestacional. Os resultados significativos (P 0.001), obtidos para a biometria do diâmetro parietal (r2 = 81%) e abdominal (r2 = 86%), área abdominal (r2 = 80%), comprimento do fêmur (r2 = 84%), comprimento (r2 = 79%), largura (r2 = 79%), área (r2 = 82%) e volume (r2 = 72%) cardíaco e área hepática (r2 = 71%) em conceptos  braquiocefálicos, podem ajudar a avaliação do desenvolvimento dos fetos, complementando a ultrassonografia gestacional de cadelas e como modelo para o estudo em outrasraças de cães e espécies animais.(AU)


Assuntos
Animais , Feminino , Cães , Prenhez/fisiologia , Ultrassonografia/métodos , Pesos e Medidas , Pesos e Medidas Corporais/veterinária , Fêmur/anatomia & histologia , Placenta/anatomia & histologia , Abdome/anatomia & histologia
2.
Ci. Anim. bras. ; 16(3)2015.
Artigo em Inglês | VETINDEX | ID: vti-745102

RESUMO

title>Abstract /title> p>Ultrasonography is an accurate pregnancy diagnostic method, besides being completely innocuous for female and fetuses evaluation. The objective of this paper was to determine the reference values for gestational echo biometry of different breeds of bitches. A total of 25 multiparous females were included in the experiment, five English Bulldog bitches, five Pugs and 15 Shih Tzu, weighing 4-25 kg and aged 4-6 years. The echo biometric assessments were performed during the 2nd, 5th, 6th, 7th and 8th weeks of pregnancy, including gestational vesicle diameter, femur length, placenta thickness, parietal diameter, liver, heart and abdominal diameter and area. Early echo biometric study started at the second week of gestation. Measurements like fetal heart and liver diameter and area are still poorly studied, but can provide useful information for early detection of congenital anomalies that may reduce the viability of pregnancy. The significant results (P 0.001) obtained for biometrics (P 0.001) of the parietal (r sup>2 /sup> = 81%) and abdominal diameter (r sup>2 /sup> = 86%), abdominal area (r sup>2 /sup> = 80%), femur length (r sup>2 /sup> = 84%), cardiac length (r sup>2 /sup> = 79%), width (r sup>2 /sup> = 79%), area (r sup>2 /sup> = 82%) and volume (r sup>2 /sup>= 72%) and liver area (r sup>2 /sup> = 71%) in brachycephalic conceptus may help to assess the development of fetuses, complementing the conventional gestational ultrasound of bitches and become a model for the study in other breeds of dogs and alternative animal species. /p>


title>Resumo /title> p>O exame ultrassonográfico é um meio de diagnóstico preciso para avaliação da gestação, além de ser totalmente inócuo para fêmea e fetos. Objetivou-se com este estudo determinar os valores de referência para a ecobiometria gestacional em cadelas de diferentes raças. Foram utilizadas 25 fêmeas multíparas, sendo cinco cadelas Bulldog inglês, cinco Pugs e 15 Shih Tzu, pesando de 4 a 25 kg e com idade entre 4 a 6 anos. As avaliações ecobiométricas como diâmetro da vesícula gestacional, comprimento femoral, espessura da placenta, diâmetro parietal, diâmetro e área abdominal, hepática e cardíaca foram realizadas durante as 2ª, 5ª, 6ª, 7ª e 8ª semanas gestacionais das cadelas. O estudo ecobiométrico em cadelas gestantes foi precocemente iniciado a partir da segunda semana gestacional. Mensurações pouco estudadas como o diâmetro e área hepática e valores ecobiométricos do coração fetal, podem fornecer informações úteis para a detecção precoce de anomalias congênitas que podem comprometer a viabilidade gestacional. Os resultados significativos (P 0.001), obtidos para a biometria do diâmetro parietal (r sup>2 /sup> = 81%) e abdominal (r sup>2 /sup>= 86%), área abdominal (r sup>2 /sup> = 80%), comprimento do fêmur (r sup>2 /sup> = 84%), comprimento (r sup>2 /sup> = 79%), largura (r sup>2 /sup> = 79%), área (r sup>2 /sup> = 82%) e volume (r sup>2 /sup> = 72%) cardíaco e área hepática (r sup>2 /sup> = 71%) em conceptos braquiocefálicos, podem ajudar a avaliação do desenvolvimento dos fetos, complementando a ultrassonografia gestacional de cadelas e como modelo para o estudo em outras raças de cães e espécies animais. /p>

3.
Ciênc. anim. bras. (Impr.) ; 16(3): 419-427, Jul-Set. 2015. ilus, tab
Artigo em Inglês | VETINDEX | ID: biblio-1473401

RESUMO

Ultrasonography is an accurate pregnancy diagnostic method, besides being completely innocuous for female and fetuses evaluation. The objective of this paper was to determine the reference values for gestational echo biometry of different breeds of bitches. A total of 25 multiparous females were included in the experiment, five English Bulldog bitches, five Pugs and 15 Shih Tzu, weighing 4-25 kg and aged 4-6 years. The echo biometric assessments were performed during the 2nd, 5th, 6th, 7th and 8th weeks of pregnancy, including gestational vesicle diameter, femur length, placenta thickness, parietal diameter, liver, heart and abdominal diameter and area. Early echo biometric study started at the second week of gestation. Measurements like fetal heart and liver diameter and area are ??still poorly studied, but can provide useful information for early detection of congenital anomalies that may reduce the viability of pregnancy. The significant results (P 0.001) obtained for biometrics (P 0.001) of the parietal (r2 = 81%) and abdominal diameter (r2 = 86%), abdominal area (r2 = 80%), femur length (r2 = 84%), cardiac length (r2 = 79%), width (r2 = 79%), area (r2 = 82%) and volume (r2 = 72%) and liver area (r2 = 71%) in brachycephalic conceptus may help to assess the development of fetuses, complementing the conventional gestational ultrasound of bitches and become a model for the study in other breeds of dogs and alternative animal species.


O exame ultrassonográfico é um meio de diagnóstico preciso para avaliação da gestação, além de ser totalmente inócuo para fêmea e fetos. Objetivou-se com este estudo determinar os valores de referência para a ecobiometria gestacional em cadelas de diferentes raças. Foram utilizadas 25 fêmeas multíparas, sendo cinco cadelas Bulldog inglês, cinco Pugs e 15 Shih Tzu, pesando de 4 a 25 kg e com idade entre 4 a 6 anos. As avaliações ecobiométricas como diâmetro da vesícula gestacional, comprimento femoral, espessura da placenta, diâmetro parietal, diâmetro e área abdominal, hepática e cardíaca foram realizadas durante as 2ª, 5ª, 6ª, 7ª e 8ª semanas gestacionais das cadelas. O estudo ecobiométrico em cadelas gestantes foi precocemente iniciado a partir da segunda semana gestacional. Mensurações pouco estudadas como o diâmetro e área hepática e valores ecobiométricos do coração fetal, podem fornecer informações úteis para a detecção precoce de anomalias congênitas que podem comprometer a viabilidade gestacional. Os resultados significativos (P 0.001), obtidos para a biometria do diâmetro parietal (r2 = 81%) e abdominal (r2 = 86%), área abdominal (r2 = 80%), comprimento do fêmur (r2 = 84%), comprimento (r2 = 79%), largura (r2 = 79%), área (r2 = 82%) e volume (r2 = 72%) cardíaco e área hepática (r2 = 71%) em conceptos  braquiocefálicos, podem ajudar a avaliação do desenvolvimento dos fetos, complementando a ultrassonografia gestacional de cadelas e como modelo para o estudo em outrasraças de cães e espécies animais.


Assuntos
Feminino , Animais , Cães , Pesos e Medidas , Pesos e Medidas Corporais/veterinária , Prenhez/fisiologia , Ultrassonografia/métodos , Abdome/anatomia & histologia , Fêmur/anatomia & histologia , Placenta/anatomia & histologia
4.
Ci. Vet. Tróp. ; 12(1/2/3): 28-34, 2009.
Artigo em Português | VETINDEX | ID: vti-479383

RESUMO

In order to determine the accuracy of the pregnant diagnosis method according embryonic vesicles number (VEs) and correlate the litter size with the number of embryonic vesicles counted during the ultrasound mode-B exam, a total of 79 sows were used, between the 21st and 22nd day of gestation, examined by abdominal ultrasound device (Aloka SSD 500) equipped with a convex sectorial probe (5.0 MHz). The diagnosis accuracy (92.1%)did not suffer influences of the quantity of VEs and the size of litter, although it was higher when the number of pigs and the number of vesicles were superior to eight. There was no correlation between litter size and the number of vesicles counted during the ultrasound exam, the positive results were only of 20.5%. Then, it was concluded that the ultrasonography is a possibility to diagnose gestation with high accuracy, however, the 5MHz probe was not successful in predicting the number of newborn piglets.


Neste trabalho objetivou-se avaliar a acurácia da ultrassonografia Modo-B como método diagnóstico de gestação nos dias 21 e 22 pós-inseminação artificial, de acordo com o número de vesículas embrionárias (VEs) contadas, bem como correlacionar o número total de leitões nascidos com o número de vesículas contabilizadas, durante o exame ultrassonográfico. Foram utilizadas 79 fêmeas suínas, entre os dias 21 e 22 de gestação, examinadas via transcutânea com aparelho de ultrassom (Aloka SSD 500) equipado com transdutor setorial convexo de 5,0 MHz. A acurácia do diagnóstico (92,1%) não sofreu influência da quantidade de VEs, nem do tamanho da leitegada, apesar de ter sido levemente maior quando o número de VEs e de leitões nascidos foram iguais ou superiores a oito. A correlação entre o número de leitões e o número de vesículas contabilizadas durante o exame ultrassonográfico foi baixa e não significante. O percentual de acerto foi de apenas 20,5%. Diante do exposto, conclui-se que a ultrassonografia na produção suína é um método eficiente no diagnóstico precoce de gestação. No entanto, o transdutor de 5,0 MHz não é recomendado para a previsão do tamanho da leitegada nestas condições.

5.
Ciênc. vet. tróp ; 12(1/2/3): 28-34, 2009.
Artigo em Português | LILACS-Express | VETINDEX | ID: biblio-1480391

RESUMO

In order to determine the accuracy of the pregnant diagnosis method according embryonic vesicles number (VEs) and correlate the litter size with the number of embryonic vesicles counted during the ultrasound mode-B exam, a total of 79 sows were used, between the 21st and 22nd day of gestation, examined by abdominal ultrasound device (Aloka SSD 500) equipped with a convex sectorial probe (5.0 MHz). The diagnosis accuracy (92.1%)did not suffer influences of the quantity of VEs and the size of litter, although it was higher when the number of pigs and the number of vesicles were superior to eight. There was no correlation between litter size and the number of vesicles counted during the ultrasound exam, the positive results were only of 20.5%. Then, it was concluded that the ultrasonography is a possibility to diagnose gestation with high accuracy, however, the 5MHz probe was not successful in predicting the number of newborn piglets.


Neste trabalho objetivou-se avaliar a acurácia da ultrassonografia Modo-B como método diagnóstico de gestação nos dias 21 e 22 pós-inseminação artificial, de acordo com o número de vesículas embrionárias (VEs) contadas, bem como correlacionar o número total de leitões nascidos com o número de vesículas contabilizadas, durante o exame ultrassonográfico. Foram utilizadas 79 fêmeas suínas, entre os dias 21 e 22 de gestação, examinadas via transcutânea com aparelho de ultrassom (Aloka SSD 500) equipado com transdutor setorial convexo de 5,0 MHz. A acurácia do diagnóstico (92,1%) não sofreu influência da quantidade de VEs, nem do tamanho da leitegada, apesar de ter sido levemente maior quando o número de VEs e de leitões nascidos foram iguais ou superiores a oito. A correlação entre o número de leitões e o número de vesículas contabilizadas durante o exame ultrassonográfico foi baixa e não significante. O percentual de acerto foi de apenas 20,5%. Diante do exposto, conclui-se que a ultrassonografia na produção suína é um método eficiente no diagnóstico precoce de gestação. No entanto, o transdutor de 5,0 MHz não é recomendado para a previsão do tamanho da leitegada nestas condições.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA