Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Rev Port Cardiol ; 42(9): 759-769, 2023 09.
Artigo em Inglês, Português | MEDLINE | ID: mdl-36948457

RESUMO

INTRODUCTION: Current rates of permanent pacemaker implantation (PPMI) after transcatheter aortic valve implantation (TAVI) range between 3.4% and 25.9%. PPMI is associated with a worse prognosis. A lower valve implantation depth is associated with an increased risk of conduction disturbances. Theoretically, cusp-overlap projection (COP) has the potential to enable higher valve deployment. OBJECTIVE: To compare the 30-day PPMI incidence post-TAVI using self-expanding valves according to the fluoroscopic guidance technique. METHODS: This retrospective single-center study assessed consecutive patients undergoing TAVI with CoreValve™ valves between April 2019 and November 2021, grouped according to the fluoroscopic guidance technique (COP vs. coplanar implantation technique [CIT]). RESULTS: A total of 122 patients were included, predominantly women (52.5%), with a mean age of 81.6±5.5 years. COP was used in 49.2% of the sample. The CIT group had a significantly higher prevalence of previous beta-blocker use (p<0.01), lower baseline left ventricular ejection fraction (p=0.04) and a higher EuroSCORE II (p=0.02). The 30-day PPMI rate was 27.9% (n=34), with no significant difference between the COP and CIT groups (26.7% vs. 29.0%, p=0.77). Complete atrioventricular block was the main cause (38.5%). Likewise, mean fluoroscopy time (p=0.14) and contrast volume (p=0.35) used were similar between the two groups. Radiation dose was lower in the COP group (p=0.02). There was no significant difference between post-TAVI grades III and IV aortic valve regurgitation (p=0.27) and there were no cases of periprocedural acute coronary occlusion. CONCLUSIONS: This study shows that the COP technique, although safe and not associated with increased complexity, did not significantly reduce the 30-day PPMI rate compared to the traditional CIT view.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Volume Sistólico , Incidência , Estudos Retrospectivos , Resultado do Tratamento , Fatores de Risco , Função Ventricular Esquerda
2.
Arq. bras. cardiol ; 119(4): 522-530, Oct. 2022. tab, graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1403353

RESUMO

Resumo Fundamento Os distúrbios de condução (DC) são a complicação mais frequente após a substituição da válvula aórtica transcateter (TAVR) e ainda não há consenso sobre seu tratamento. Objetivo Avaliar novos DC e implante de marca-passo definitivo (MPD) após a TAVR e avaliar a porcentagem de estimulação ventricular (EV) até 1 ano de acompanhamento. Métodos Pacientes submetidos a TAVR de outubro de 2014 a novembro de 2019 foram cadastrados; pacientes com MPD anterior foram excluídos. Dados clínicos, do procedimento, do ECG e do MPD foram coletados até 1 ano após o implante. O nível de significância adotado para a análise estatística foi 0,05%. Resultados Um total de 340 indivíduos foram submetidos a TAVR. O DC mais comum foi bloqueio de ramo esquerdo novo (BRE; 32,2%), sendo que 56% destes foram resolvidos após 6 meses. O bloqueio do ramo direito (BRD) foi o maior fator de risco para bloqueio atrioventricular avançado (BAV) [RC=8,46; p<0,001] e implante de MPD [RC=5,18; p<0,001], seguido de BAV de baixo grau prévio [RC=2,25; p=0,016 para implante de MPD]. Em relação às características do procedimento, válvulas de gerações mais recentes e procedimentos de válvula-em-válvula foram associados a menos DC. No total, 18,5% dos pacientes tiveram MPD implantado após a TAVR. Na primeira avaliação do MPD, pacientes com BAV avançado tinham uma porcentagem mediana de EV de 80%, e, após um ano, de 83%. Em relação aos pacientes com BRE e BAV de baixo grau, a EV mediana foi mais baixa (6% na primeira avaliação, p=0,036; 2% após um ano, p = 0,065). Conclusão O BRE foi o DC mais frequente após a TAVR, com mais da metade dos casos se resolvendo nos primeiros 6 meses. O BRD foi o principal fator de risco para BAV avançado e implante de MPD. O BAV avançado foi associado a uma porcentagem mais alta de EV no acompanhamento de 1 ano.


Abstract Background Conduction disturbances (CD) are the most frequent complication after transcatheter aortic valve replacement (TAVR), and there continues to be a lack of consensus on their management. Objective To assess new CD and permanent pacemaker (PPM) implantation after TAVR and to evaluate the ventricular pacing percentage (VP) up to 1 year of follow-up. Methods Patients who underwent TAVR from October 2014 to November 2019 were enrolled; patients with previous PPM were excluded. Clinical, procedure, ECG, and PPM data were collected up to 1 year after implantation. The significance level adopted in the statistical analysis was 0.05. Results A total of 340 patients underwent TAVR. The most frequent CD was the new left bundle branch block (LBBB; 32.2%), which 56% resolved after 6 months. Right bundle branch block (RBBB) was the biggest risk factor for advanced atrioventricular block (AVB) [OR=8.46; p<0.001] and PPM implantation [OR=5.18, p<0.001], followed by previous low-grade AVB [OR=2.25; p=0.016 for PPM implantation]. Regarding procedure characteristics, newer generation valves and valve-in-valve procedures were associated with fewer CDs. Overall, 18.5% of patients had a PPM implanted post-TAVR. At first PPM evaluation, patients with advanced AVB had a median percentage of VP of 80% and 83% at one year. Regarding patients with LBBB plus low-grade AVB, median VP was lower (6% at first assessment, p=0.036; 2% at one year, p = 0.065). Conclusion LBBB was the most frequent CD after TAVR, with more than half being resolved in the first six months. RBBB was the major risk factor for advanced AVB and PPM implantation. Advanced AVB was associated with a higher percentage of VP at 1 year of follow-up.

4.
Rev. urug. cardiol ; 35(3): 470-494, dic. 2020. graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1145092

RESUMO

Resumen: Durante el posoperatorio de cirugía cardíaca es frecuente observar trastornos en la generación o conducción del ritmo cardíaco, o en ambos, los cuales en su mayoría son transitorios. Sin embargo, un porcentaje de ellos requerirán implante de marcapasos definitivo. Conocer los predictores preoperatorios que se asocian a implante de marcapasos definitivo (características del paciente, tipo de cirugía, etcétera) nos permitirá adecuar el tratamiento y reducir la morbimortalidad, la estadía hospitalaria y los costos sanitarios durante el posoperatorio.


Summary: During postoperative care of cardiac surgery heart rhythm disorders are frequently seen. Most of them are transient, but some may need permanent pacemaker implantation. Knowing preoperative permanent pacemaker implantation predictors (i.e. patients characteristics, surgery type, etc.) will allow us to provide a better patient treatment, reduce morbidity and mortality, in-hospital length of stay and health care costs.


Resumo: Durante o período pós-operatório de cirurgia cardiaca é comum observar distúrbios na geração e/ou condução do ritmo cardíaco, que em sua maioria, são transitórios. No entanto, uma porcentagem deles exigirá o implante do marcapasso definitivo. Por este motivo, é fundamental o conhecimento dos preditores pré-operatórios associados à implantação definitiva do marcapasso (características do paciente, tipo de cirurgia, etc.) para que se possa melhorar o tratamento e reduzir a morbimortalidade, o tempo de internação e os custos de saúde.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...