Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 205
Filtrar
1.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38885741

RESUMO

INTRODUCTION AND OBJECTIVES: Different degrees of testicular torsion result in varying degrees of testicular damage, which influences treatment options and outcomes. Therefore, establishing a testicular torsion model with different degrees is necessary for clinical diagnosis. MATERIALS AND METHODS: Rabbits were randomly divided into four groups and their spermatic cords were twisted at 0 °, 180 °, 360 °, and 720 °, respectively. Color Doppler flow imaging (CDFI) were performed to evaluate the blood supply in testicles. The twisted testicles were surgically removed at six hours post-operation and were evaluated by morphological observation and Hematoxylin and Eosin staining. RESULTS: CDFI signals were gradually decreased as the degree of testicular torsion increased, and scores of CDFI in the 360 ° and 720 ° groups were significantly decreased at postoperative six hours compared to pre-surgery. Compared to the sham, the testicle in the 180 ° group exhibited slight congestion, whereas the testicles in the 360 ° and 720 ° groups were dark red in color and had severe congestion and unrecognizable vessels. Hematoxylin and Eosin staining showed mild spermatogenic cell reduction and testicular interstitial hemorrhage in the 180 ° group. In the 360 ° and 720 ° groups, disordered seminiferous tubules, shed spermatogenic cells in tubules, inflammatory cell infiltration, and severe hemorrhage were found. In comparison with the sham, interstitial hemorrhage scores in the 360 ° and 720 ° groups were significantly higher, and scores of germinal epithelial cell thickness in the three testicular torsion groups were significantly decreased. CONCLUSIONS: Collectively, we successfully constructed a testicular torsion model with different degrees in rabbits.

2.
Int Dent J ; 2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38851930

RESUMO

OBJECTIVES: During caries progression, dental pulp is increasingly pathologically affected. Since the accurate assessment of pulp is of vital importance in clinical decision-making, this study aimed to evaluate pulpal condition in the early stages of caries via laser Doppler (LD) flowmetry and histologic analysis and determine their agreement. METHODS: Fourteen patients with severe dental crowding were included. Prior to extractions and orthodontic treatment, dental pulp condition of 52 premolars was evaluated via LD flowmetry. Teeth were assessed for the presence of caries and lesions were graded according to the International Caries Detection and Assessment System (ICDAS). After extractions, teeth were split and histologically stained for endothelial cells with anti-von Willebrand factor and Movat pentachrome for collagen. Volume densities of vessels (Vvasc) and collagen were calculated. RESULTS: There was a significant negative correlation between LD flow and Vvasc of the dental pulp with ICDAS grade. Pulpal LD flow and Vvasc in teeth with the initial lesion were increased, decreasing with progressing stages of caries. A significant positive correlation between the the pulpal LD flow and Vvasc, and a negative correlation of LD flow with collagen fibre density were noted. CONCLUSIONS: Caries affects the physiology of the dental pulp, initially with increasing vascularity, and decreasing vascularity at later stges of caries progression. Collagen contents increase with grades of ICDAS. LD flow shows good agreement with the histologic constitution of the dental pulp. Use of clinical measurements of pulpal LD flow could provide a good noninvasive indication of pulpal vascular state and its health.

3.
Eur J Obstet Gynecol Reprod Biol ; 299: 278-282, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38935997

RESUMO

OBJECTIVE: To assess the accuracy of diagnosing retained products of conception (RPOC) in symptomatic versus asymptomatic women, and to identify potential divergent ultrasound features between these groups. METHODS: This retrospective study included women aged 17-50 years who underwent hysteroscopy for suspected RPOC during 2018-2021. Clinical and sonographic data were analyzed, and multivariable linear regression models employed, to examine correlations between RPOC and sonographic findings, and to compare diagnostic accuracy between symptomatic and asymptomatic women. RESULTS: Of the 225 women included, 123 (54.7 %) were symptomatic and 102 (45.3 %) were asymptomatic. Hysteroscopy complications were more frequent in asymptomatic women. Regarding sonography, statistically significant differences were not found between the groups in endometrial thickness or uterine fluid presence, but positive Doppler flow was more common in asymptomatic than symptomatic women. Endometrial thickness >1.49 cm demonstrated diagnostic utility, with similar sensitivity and specificity in the two groups. Multivariable models revealed significant associations of RPOC presence with endometrial thickness and Doppler flow in symptomatic women. In both groups, hysteroscopy enhanced diagnostic accuracy, with higher positive predictive values and lower false-positive rates compared to ultrasound alone. CONCLUSION: An endometrial thickness cutoff of 1.49 cm aids diagnosing RPOC. Doppler flow enhances diagnostic value in symptomatic women. Integration of hysteroscopy improves diagnostic accuracy compared to ultrasound alone. Regular sonographic assessment for women with identifiable risk factors assists in RPOC detection irrespective of symptoms.

4.
bioRxiv ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38798364

RESUMO

Alzheimer's Disease (AD) is a global health issue, affecting over 6 million in the United States, with that number expected to increase as the aging population grows. As a neurodegenerative disorder that affects memory and cognitive functions, it is well established that AD is associated with cardiovascular risk factors beyond only cerebral decline. However, the study of cerebrovascular techniques for AD is still evolving. Here, we provide reproducible methods to measure impedance-based pulse wave velocity (PWV), a marker of arterial stiffness, in the systemic vascular (aortic PWV) and in the cerebral vascular (cerebral PWV) systems. Using aortic impedance and this relatively novel technique of cerebral impedance to comprehensively describe the systemic vascular and the cerebral vascular systems, we examined the sex-dependent differences in 5x transgenic mice (5XFAD) with AD under normal and high-fat diet, and in wild-type mice under a normal diet. Additionally, we validated our method for measuring cerebrovascular impedance in a model of induced stress in 5XFAD. Together, our results show that sex and diet differences in wildtype and 5XFAD mice account for very minimal differences in cerebral impedance. Interestingly, 5XFAD, and not wildtype, male mice on a chow diet show higher cerebral impedance, suggesting pathological differences. Opposingly, when we subjected 5XFAD mice to stress, we found that females showed elevated cerebral impedance. Using this validated method of measuring impedance-based aortic and cerebral PWV, future research may explore the effects of modifying factors including age, chronic diet, and acute stress, which may mediate cardiovascular risk in AD.

5.
Clin Cosmet Investig Dermatol ; 17: 1183-1191, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38800356

RESUMO

Background: Hematoporphyrin monomethyl ether (HMME) is a promising photosensitizer for photodynamic therapy (PDT) and has found wide application in the treatment of port-wine stains (PWS). Objective: This study aims to observe and analyze the clinical efficacy and safety of HMME-PDT in the treatment of PWS patients. It also aims to evaluate the usefulness of color Doppler flow imaging (CDFI), an ultrasound technique for detecting blood flow in skin lesions, in assessing clinical efficacy. Methods: Thirty-three patients with PWS underwent HMME-PDT at our dermatology outpatient clinic between January 2019 and March 2020. Data on patient demographics, lesion location, lesion type (pink, purple, nodular thickening), treatment frequency, and pre- and post-treatment images were collected and retrospectively analyzed. CDFI was performed on three patients. Results: All patients received intravenous HMME and underwent irradiation with 532 nm green LED light. Of these, 5 patients received 1 session of HMME-PDT, 14 received 2 sessions, 9 received 3 sessions and the remaining 5 patients received more than 3 sessions. Of the 33 patients, 9 were cured (27.27%), 10 showed improvement (30.30%), 11 experienced a reduction in symptoms (33.33%), and 3 showed no significant improvement (9.09%). Most patients reported local pain and oedema, and no systemic adverse effects were observed. Clinical efficacy correlated with lesion type and total number of treatment sessions. CDFI appears to be an excellent technique for assessing clinical efficacy. Conclusion: HMME-PDT is a safe and effective method for the treatment of PWS. CDFI examination appears to be a promising assessment tool. However, further validation with larger sample sizes is warranted.

6.
J Ultrasound Med ; 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38581195

RESUMO

OBJECTIVES: Our study aims to investigate the impact of B-mode ultrasound (B-US) imaging, color Doppler flow imaging (CDFI), strain elastography (SE), and patient age on the prediction of molecular subtypes in breast lesions. METHODS: Totally 2272 multimodal ultrasound imaging was collected from 198 patients. The ResNet-18 network was employed to predict four molecular subtypes from B-US imaging, CDFI, and SE of patients with different ages. All the images were split into training and testing datasets by the ratio of 80%:20%. The predictive performance on testing dataset was evaluated through 5 metrics including mean accuracy, precision, recall, F1-scores, and confusion matrix. RESULTS: Based on B-US imaging, the test mean accuracy is 74.50%, the precision is 74.84%, the recall is 72.48%, and the F1-scores is 0.73. By combining B-US imaging with CDFI, the results were increased to 85.41%, 85.03%, 85.05%, and 0.84, respectively. With the integration of B-US imaging and SE, the results were changed to 75.64%, 74.69%, 73.86%, and 0.74, respectively. Using images from patients under 40 years old, the results were 90.48%, 90.88%, 88.47%, and 0.89. When images from patients who are above 40 years old, they were changed to 81.96%, 83.12%, 80.5%, and 0.81, respectively. CONCLUSION: Multimodal ultrasound imaging can be used to accurately predict the molecular subtypes of breast lesions. In addition to B-US imaging, CDFI rather than SE contribute further to improve predictive performance. The predictive performance is notably better for patients under 40 years old compared with those who are 40 years old and above.

7.
World J Cardiol ; 16(1): 5-9, 2024 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-38313388

RESUMO

The World Journal of Cardiology published an article written by Kuwahara et al that we take the pleasure to comment on. We focused our attention on venous congestion. In intensive care settings, it is now widely accepted that venous congestion is an important clinical feature worthy of investigation. Evaluating venous Doppler profile abnormalities at multiple sites could suggest adequate treatment and monitor its efficacy. Renal dysfunction could trigger or worsen fluid overload in heart disease, and cardio-renal syndrome is a well-characterized spectrum of disorders describing the complex interactions between heart and kidney diseases. Fluid overload and venous congestion, including renal venous hypertension, are major determinants of acute and chronic renal dysfunction arising in heart disease. Organ congestion from venous hypertension could be involved in the development of organ injury in several clinical situations, such as critical diseases, congestive heart failure, and chronic kidney disease. Ultrasonography and abnormal Doppler flow patterns diagnose clinically significant systemic venous congestion. Cardiologists and nephrologists might use this valuable, non-invasive, bedside diagnostic tool to establish fluid status and guide clinical choices.

8.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(1): 1-5, 2024 Jan 30.
Artigo em Chinês | MEDLINE | ID: mdl-38384208

RESUMO

Vector flow imaging (VFI) is an innovative ultrasound flow measurement technology. Compared with the traditional color Doppler and spectral Doppler, VFI has the advantages of independence of angle correction and direct acquisition of real-time amplitude and direction of flow. Transverse oscillation (TO) method is one of the effective methods for vector flow imaging. However, a complete and detailed algorithm validation process based on commercial ultrasound machines is still lacking due to more complex convex probes. This study starts with introducing the imaging process and principle of transverse oscillation vector flow technique, and calculates the error between the set velocity value and the measured velocity value through the simulation experiment, and verifies the error between the set velocity value and the measured velocity value through the Doppler flow phantom experiment. Among them, the velocity value measured by the TO vector flow technique in the simulation experiment is 0.48 m/s and the preset value is 0.50 m/s, the error between them is -4%. The velocity values are 8.33, 11.14, 14.44 and 16.67 cm/s measured by the Doppler flow phantom experiment, the actual velocity values are 7.97, 10.78, 14.06 and 17.34 cm/s, the errors between them are all within ±5%. Both experiments verify the feasibility of using vector flow technique on abdominal convex probe.


Assuntos
Abdome , Ultrassom , Velocidade do Fluxo Sanguíneo , Ultrassonografia , Abdome/diagnóstico por imagem , Imagens de Fantasmas , Ultrassonografia Doppler em Cores
9.
Skin Res Technol ; 30(2): e13585, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38279551

RESUMO

BACKGROUND: Pilomatricoma has various manifestations on color Doppler ultrasound, and a differential diagnosis is challenging. The objective of this study was to investigate which characteristics of skin lesions on color Doppler ultrasound are effective in distinguishing pilomatricoma from epidermoid cyst and dermatofibrosarcoma protuberans. MATERIALS AND METHODS: Records of patients with pilomatricomas (n = 63), epidermoid cysts (n = 76), and dermatofibrosarcoma protuberans (n = 19) who underwent color Doppler ultrasound evaluation and surgical excision were reviewed. The anatomical distribution and color Doppler ultrasound characteristics of these lesions were analyzed. The 63 pilomatricomas were categorized into five types based on their color Doppler ultrasound characteristics, and the roles of these five types in the differential diagnosis of the aforementioned diseases were studied. RESULTS: Pilomatricomas, epidermoid cysts, and dermatofibrosarcoma protuberans exhibited some similar characteristics. Dominantly markedly hyperechoic or hyperechoic appearance, posterior acoustic shadowing, and the presence of vascularity were the major characteristics of pilomatricomas. The pilomatricomas could be categorized into five types, with type II having a diagnostic performance of sensitivity of 65.08%, specificity of 98.95%, area under the receiver operating characteristic curve (AUC) of 0.743, positive predictive value of 97.62%, and negative predictive value of 81.03% for the diagnosis of the aforementioned skin diseases. CONCLUSION: A combination of dominantly markedly hyperechoic or hyperechoic appearance, posterior acoustic shadowing, and the presence of vascularity exhibits higher diagnostic performance for the differential diagnosis of pilomatricomas, epidermoid cysts, and dermatofibrosarcoma protuberans.


Assuntos
Dermatofibrossarcoma , Cisto Epidérmico , Pilomatrixoma , Neoplasias Cutâneas , Humanos , Pilomatrixoma/diagnóstico por imagem , Cisto Epidérmico/diagnóstico por imagem , Dermatofibrossarcoma/diagnóstico por imagem , Ultrassonografia/métodos , Neoplasias Cutâneas/diagnóstico por imagem , Neoplasias Cutâneas/patologia , Diagnóstico Diferencial
10.
Quant Imaging Med Surg ; 14(1): 877-887, 2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38223094

RESUMO

Background: Sclerosing adenosis (SA) is a common proliferative benign lesion without atypia in the breast that may mimic invasive ductal carcinoma (IDC) on medical imaging, leading to it often being misdiagnosed and mistreated. Consequently, the purpose of this study was to assess the diagnostic value of multimodal ultrasound imaging in distinguishing SA from IDC. Methods: Multimodal ultrasound imaging, including automated breast volume scan (ABVS), elasticity imaging (EI), and color Doppler flow imaging (CDFI), were performed on 120 consecutive patients comprising 122 breast lesions (54 SA, 68 IDC). All lesions were pathologically confirmed. Multimodal ultrasound imaging features were compared between the two groups. Binary logistic regression analysis based on ABVS, EI, and CDFI was conducted to formulate a logistic regression equation for differentiating SA from IDC. The diagnostic performances of ABVS, EI, CDFI, and their combination were compared by the receiver operating characteristic (ROC) curve analysis. Results: The sensitivity, specificity, and accuracy of ABVS, EI, CDFI, and their combination in differentiating SA from IDC were, respectively, 75.00%, 72.22%, and 73.77%; 86.76%, 72.22%, and 80.33%; 73.53%, 64.81%, and 69.67%; and 88.24%, 74.07%, and 81.97%. Combining multimodal ultrasound imaging yielded an area under the curve (AUC) of 0.895 (95% confidence interval: 0.827-0.943), which was higher than that of ABVS, EI, and CDFI, with AUC values of 0.736, 0.795, and 0.692, respectively, and the difference was statistically significant (ABVS vs. combined model, P<0.001; CDFI vs. combined model, P<0.001; EI vs. combined model, P<0.001). There was no significant difference in the diagnostic efficacy among the three imaging modalities (ABVS vs. EI, P=0.266; ABVS vs. CDFI, P=0.4671; EI vs. CDFI, P=0.051). Compared with those in IDC, the calcification (16.67% vs. 57.35%; P<0.001) and retraction phenomena in the coronal planes (18.52% vs. 57.35%; P<0.001) were less common in patients with SA, while circumscribed margin (38.89% vs. 5.88%; P<0.001), vascularity grade 0-I (64.81% vs. 26.47%; P<0.001), and elasticity scores 1-3 (72.22% vs. 13.24%; P<0.001) were more frequently found in patients with SA. Patients with SA were significantly younger than were patients with IDC (43±11 vs. 54±11 years; P<0.001), and the lesion size was smaller in patients with SA than in those with IDC (median size 1.0 cm; interquartile range (IQR), 0.9 cm vs. median size 1.3 cm; IQR, 1.3 cm; P<0.001). Conclusions: The preliminary results suggested that multimodal ultrasound imaging can improve the diagnostic accuracy of SA and provide additional information for differential diagnosis of SA and IDC.

11.
J Pediatr ; 266: 113864, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38052293

RESUMO

OBJECTIVES: To characterize pulmonary artery Doppler flow profile (PAFP) patterns among infants receiving care in neonatal intensive care units and to examine the association of PAFP patterns with pulmonary and right ventricular (RV) hemodynamics. STUDY DESIGN: This is a retrospective study at 2 tertiary intensive care units over 4 years that included neonates who demonstrated a complete tricuspid regurgitation envelope on targeted neonatal echocardiography. Separate personnel reviewed TNEs to characterize PAFP patterns, divide cohort into PAFP groups, and measure quantitative indices of RV hemodynamics (RV systolic pressure, pulmonary artery acceleration time and its ratio with RV ejection time, tricuspid annular plane systolic excursion, and RV output), for intergroup comparisons. RESULTS: We evaluated TNEs from 186 neonates with median gestational age of 28.5 weeks (IQR, 25.9-35.9 weeks). Four distinct PAFP patterns were identified (A) near-isosceles triangle (22%), (B) right-angled triangle (29%), (C) notching (40%), and (D) low peak velocity (<0.4 m/s; 9%). Groups A-C demonstrated a stepwise worsening in all indices of PH, whereas pattern D was associated with lower tricuspid annular plane systolic excursion and RV output. Using common definitions of pulmonary hypertension (PH), pattern A performed best to rule out PH (sensitivity range, 81%-90%) and pattern C for diagnosing PH (specificity range, 63%-78%). CONCLUSIONS: Inspection of PAFP is a simple bedside echocardiography measure that provides clinically meaningful information on underlying RV hemodynamics and may aid in screening and monitoring of patients for PH in intensive care units.


Assuntos
Hipertensão Pulmonar , Artéria Pulmonar , Lactente , Recém-Nascido , Humanos , Artéria Pulmonar/diagnóstico por imagem , Estudos Retrospectivos , Hipertensão Pulmonar/diagnóstico por imagem , Hemodinâmica , Unidades de Terapia Intensiva Neonatal
12.
J Cardiothorac Vasc Anesth ; 38(3): 843-847, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37953175

RESUMO

Transthoracic echocardiography is used routinely during the follow-up after heart transplant surgery to screen possible complications and adverse events such as rejection. It often results in incidental findings that bring diagnostic challenges for sonographers. This E-challenge shows a Doppler flow abnormality associated with a rare cardiovascular diagnosis. Its physiopathology and its association with echocardiography findings are reviewed.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Transplante de Coração , Humanos , Ventrículos do Coração , Ecocardiografia , Transplante de Coração/efeitos adversos , Ultrassonografia Doppler em Cores
13.
Clin Hemorheol Microcirc ; 87(1): 55-65, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38160348

RESUMO

BACKGROUND: Hepatic sarcomatoid carcinoma (HSC) is a rare malignancy of the liver. The ultrasound and clinical features of HSC have not been determined. OBJECTIVE: To investigate and compare the ultrasound and clinical features of HSC and hepatocellular carcinoma (HCC), and to reveal the valuable features of HSC. METHODS: The ultrasound features and clinical data of pathologically proven HSC (n = 37) were compared with HCC (n = 92) in a matching ratio of 1:4 using the propensity score (age, gender and tumor size). RESULTS: The HSC patients were more likely to accompany with clinical symptoms and vascular invasion than HCC patients (40.5% vs 17.4%, 24.3% vs 6.5%, P < 0.05). The size of HSCs was significantly larger than that of HCCs (P < 0.05). The proportion of patients with elevated alpha-fetoprotein was significantly lower in HSC (35.1% vs 54.3%, P < 0.05). On gray-scale ultrasound images, the HSCs were more likely to demonstrate as indistinct margin and irregular shape lesions compared to HCCs (78.4% vs 48.8%; 70.3% vs 23.9%, P < 0.05). Under color Doppler flow imaging (CDFI), the blood flow signals were more frequently detected in HSC lesions (75.7% vs 56.5%, P < 0.05). Resistance index (RI) was higher in HSCs than in HCCs [0.78 (0.70,0.82) vs 0.70 (0.62,0.76), P < 0.05]. On contrast-enhanced ultrasound (CEUS), HSCs mainly showed entirety heterogeneous hyper-enhancement (48.6%), entirety homogeneous enhancement (18.9%), peripheral and internal septal enhancement (18.9%). The incidence of non-enhanced areas inside HSC lesions was higher than that inside HCC lesions (56.8% vs 31.5%, P < 0.05). During the portal venous and late phases, most of the lesions revealed hypo-enhancement in both groups, whereas earlier washout was observed in HSCs [43.0 s (30.5,58.0) vs 60.0 s (46.3,100.0), P < 0.05]. CONCLUSIONS: CEUS features are useful in preoperative and non-invasive differentiation of hepatic sarcomatoid carcinoma and hepatocellular carcinoma.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Ultrassonografia , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Masculino , Feminino , Pessoa de Meia-Idade , Ultrassonografia/métodos , Meios de Contraste , Idoso , Adulto
14.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-1013466

RESUMO

Background@#During postmolar evacuation surveillance, beta-human chorionic gonadotropin (β-hCG) regression levels can predict invasive disease while Doppler ultrasound can assess in vivo tumor neovascularization and quantify uterine blood supply. As an ancillary tool to β-hCG monitoring, ultrasound can detect the early presence of viable trophoblastic tissues and identify patients at risk of developing postmolar gestational trophoblastic Neoplasia (PMGTN). @*Objective@#The objective of this study was to correlate uterine artery Doppler ultrasound with β-hCG levels during pre- and postmolar evacuation surveillance among patients with complete mole.@*Materials and Methods@#A cohort of patients with sonographic diagnosis of complete hydatidiform mole and managed with suction curettage in the same institution were prospectively followed up after evacuation. The pre- and postmolar evacuation surveillance period was at days 1, 7, 14, 21, 28, and 35. Monitoring of serum β-hCG levels was based on the standard regression curve. For Doppler ultrasound parameters, monitoring of the systolic/diastolic (S/D) ratio, pulsatility index (PI), resistance index (RI), and peak systolic velocity (PSV) was based on its relationship with its serum β-hCG levels. The ultrasound images generated were archived and reviewed by the authors. Descriptive and inferential statistics were utilized to analyze median differences. For the correlation of uterine artery Doppler flow parameters, analysis for the test of difference used Pearson correlation and multiple linear regression analysis for the odds ratio.@*Results@#Sixteen of the 23 enrolled patients completed the protocol (16 of 23, 69.50%). A majority had spontaneous remission (13; 81%) while 3 cases (19%) presented increasing and plateauing β-hCG levels. The pre- and post evacuation median β-hCG levels showed a significant decrease (P = 0.001). As post evacuation β-hCG levels decreased, PSV also decreased (r = 0.478, P = 0.061) while Doppler parameters, RI, PI, and S/D ratio increased. However, when post evacuation β-hCG levels rose or plateaued, Doppler parameters decreased. These changes had statistical correlation (all P < 0.05). Moreover, the magnitude of the relationship for β-hCG and Doppler parameters was moderate and ranged from 0.524 to 0.581. Among the Doppler parameters, the S/D ratio and RI of the right uterine artery strongly predicted a rise in β-hCG levels. The odds ratio of predicting increased β-hCG levels and risk of gestational trophoblastic neoplasia by the right S/D ratio were − 2683.67 (confidence interval [CI] = −271.692–5095.655; P = 0.034) and by the right RI − 66,193.34 (CI = −161,818.107–29,431.433; P = 0.046). Notably, Doppler parameter changes appeared early at day 14 up to day 35 and before the appearance of abnormal β-hCG regression patterns.@*Conclusion@#There is a strong correlation between uterine artery Doppler flow changes and β-hCG levels during postmolar evacuation surveillance. The inverse relationship of the S/D ratio, PI and RI, and β-hCG regression patterns confirms spontaneous remission of the disease. For patients with abnormal β-hCG patterns, this relationship is altered. The Doppler changes become erratic, unpredictable, and significantly decreased. These changes were detected as early as 2 weeks post evacuation. Thus, the use of ultrasound as an adjunct to β-hCG post evacuation surveillance can predict abnormal β-hCG regression patterns and identify patients at risk of developing postmolar gestational trophoblastic neoplasia (PMGTN).


Assuntos
Mola Hidatiforme , Doença Trofoblástica Gestacional , Mola Hidatiforme
15.
Cancer Manag Res ; 15: 1155-1163, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37868685

RESUMO

Background: Breast carcinoma (BC) threatens the physical and mental health of women worldwide, and early diagnosis is important for improving patient outcomes and ensuring successful treatment. Purpose: This research mainly aims to compare and analyze the value of molybdenum target X-ray and high-frequency color Doppler flow imaging (CDFI) in the early diagnosis of BC. Methods: First, 102 patients with suspected early-stage BC (ESBC) admitted to Henan Provincial People's Hospital were examined by molybdenum target X-ray and CDFI. Based on the pathological findings, the diagnostic efficiency data of the two diagnostic modalities such as positive detection rate (PDR), positive predictive value (PPV), negative predictive value (NPV), sensitivity (SEN), specificity (SPE), and accuracy (ACC), as well as imaging information like masses, microcalcifications (MCs), axillary lymph node (LN) metastases, and blood flow signal or vascular sign abnormalities were analyzed. Results: CDFI contributed to higher PDR, PRV, NPV, SEN, and ACC than molybdenum target X-ray in ESBC diagnosis, but similar SPE. The combined diagnosis of molybdenum target X-ray plus CDFI contributed to even higher PDR, PRV, NPV, SEN, and ACC than molybdenum target X-ray alone and higher ACC than CDFI. Imaging inspection revealed that the number of cases of masses, axillary LN metastases, and abnormalities in blood flow signals or vascular signs detected by CDFI was significantly higher than that by molybdenum target X-ray, while the number of MCs was significantly lower. Conclusion: Molybdenum target X-ray plus CDFI is more effective in the diagnosis of ESBC and plays a complementary role in imaging examination, which can synergistically improve the diagnostic ACC of ESBC and is worthy of clinical promotion.

16.
Vis Comput Ind Biomed Art ; 6(1): 20, 2023 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-37828411

RESUMO

Artificial intelligence (AI)-based radiomics has attracted considerable research attention in the field of medical imaging, including ultrasound diagnosis. Ultrasound imaging has unique advantages such as high temporal resolution, low cost, and no radiation exposure. This renders it a preferred imaging modality for several clinical scenarios. This review includes a detailed introduction to imaging modalities, including Brightness-mode ultrasound, color Doppler flow imaging, ultrasound elastography, contrast-enhanced ultrasound, and multi-modal fusion analysis. It provides an overview of the current status and prospects of AI-based radiomics in ultrasound diagnosis, highlighting the application of AI-based radiomics to static ultrasound images, dynamic ultrasound videos, and multi-modal ultrasound fusion analysis.

17.
Front Endocrinol (Lausanne) ; 14: 1182259, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37415660

RESUMO

Purpose: To evaluate and compare the value of conventional ultrasound-based superb microvascular imaging (SMI) and color Doppler flow imaging (CDFI) in the diagnosis of malignant thyroid nodule by meta-analysis. Methods: The literature included in the Cochrane Library, PubMed, and Embase were searched by using " superb microvascular imaging (SMI), color Doppler flow imaging (CDFI), ultrasound, thyroid nodules" as the keywords from inception through February 1, 2023. According to the inclusion and exclusion criteria, the clinical studies using SMI and CDFI to diagnose thyroid nodules were selected, and histopathology of thyroid nodules was used as reference standard. The diagnostic accuracy research quality assessment tool (QUADAS-2) was used to evaluate the quality of included literature, and the Review Manager 5.4 was used to make the quality evaluation chart. The heterogeneity test was performed on the literature that met the requirements, the combined sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio were pooled, and a comprehensive ROC curve analysis was performed. Meta-DiSc version 1.4, StataSE 12, and Review Manager 5.4 software were used. Results: Finally, 13 studies were included in this meta-analysis. A total of 815 thyroid malignant nodules were assessed. All thyroid nodules were histologically confirmed after SMI or CDFI. The combined sensitivity, specificity, PLR, NLR, DOR, and area under the SROC curve of SMI for the diagnosis of malignant thyroid nodules were 0.80(95%CI: 0.77-0.83), 0.79(95%CI: 0.77-0.82), 4.37(95%CI: 3.0-6.36), 0.23(95%CI: 0.15-0.35), 22.29(95%CI: 12.18-40.78), and 0.8944, respectively; the corresponding values of CDFI were 0.62(95%CI: 0.57-0.67), 0.81(95%CI: 0.78-0.85), 3.33(95%CI: 2.18-5.07), 0.41(95%CI: 0.27-0.64), 8.93(95%CI: 3.96-20.16), and 0.8498. Deek funnel pattern showed no significant publication bias. Conclusion: The diagnostic efficiency of SMI for malignant thyroid nodules is better than CDFI, and SMI technology can provide significantly more information on vascularity, make up for the deficiency of CDFI, and has better clinical application value. Systematic review registration: https://www.crd.york.ac.uk/PROSPERO, identifier CRD42023402064.


Assuntos
Nódulo da Glândula Tireoide , Humanos , Nódulo da Glândula Tireoide/diagnóstico por imagem , Sensibilidade e Especificidade , Diagnóstico Diferencial , Microvasos
18.
Int J Mol Sci ; 24(14)2023 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-37511318

RESUMO

The impact of the machine perfusion of donation after circulatory death (DCD) hearts with the novel Custodiol-N solution on diastolic and coronary microvascular dysfunction is unknown. Porcine DCD-hearts were maintained four hours by perfusion with normothermic blood (DCD-B), hypothermic Custodiol (DCD-C), or Custodiol-N (DCD-CN), followed by one hour of reperfusion with fresh blood, including microvascular and contractile evaluation. In another group (DCD group), one hour of reperfusion, including microvascular and contractile evaluation, was performed without a previous maintenance period (all groups N = 5). We measured diastolic function with a balloon catheter and microvascular perfusion by Laser-Doppler-Technology, resulting in Laser-Doppler-Perfusion (LDP). We performed immunohistochemical staining and gene expression analysis. The developed pressure was improved in DCD-C and DCD-CN. The diastolic pressure decrement (DCD-C: -1093 ± 97 mmHg/s; DCD-CN: -1703 ± 329 mmHg/s; DCD-B: -690 ± 97 mmHg/s; p < 0.05) and relative LDP (DCD-CN: 1.42 ± 0.12; DCD-C: 1.11 ± 0.13; DCD-B: 1.22 ± 0.27) were improved only in DCD-CN. In DCD-CN, the expression of eNOS increased, and ICAM and VCAM decreased. Only in DCD-B compared to DCD, the pathways involved in complement and coagulation cascades, focal adhesion, fluid shear stress, and the IL-6 and IL-17 pathways were upregulated. In conclusion, machine perfusion with Custodiol-N improves diastolic and microvascular function and preserves the microvascular endothelium of porcine DCD-hearts.


Assuntos
Transplante de Coração , Suínos , Animais , Transplante de Coração/métodos , Coração , Reperfusão , Perfusão/métodos , Doadores de Tecidos , Preservação de Órgãos/métodos , Morte
20.
Clin Hemorheol Microcirc ; 84(1): 43-52, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36683501

RESUMO

OBJECTIVE: To explore the value of vascular architecture detected by micro vascular imaging (MVI) in preoperative diagnosis of focal liver lesions (FLLs). METHODS: In this retrospective study, patients with surgery and histopathologically proved or radiologically confirmed FLLs were included. Vascular architecture of FLLs were acquired by color Doppler flow imaging (CDFI) and MVI on LOGIQ™ E20 ultrasound machine (C1-6 convex array probes). Alder semiquantitative analysis (grade 0-3) and morphologic features of blood vessels (pattern a-f) were used to assess the blood flow within the FLLs. Interobserver agreement for evaluating blood flow of FLLs was analyzed. Using Adler's grading or morphologic patterns as diagnostic criteria for malignant FLLs, the diagnostic efficiency was analyzed and compared. RESULTS: From October 2021 and February 2022, 50 patients diagnosed with 40 malignant FLLs and 10 benign FLLs were finally included. The Kappa value within two observers for evaluating the blood flow of FLLs was 0.78 for MVI and 0.55 for CDFI. According to Alder semiquantitative analysis, more high-level blood flow signals (grade 2-3) were detected by MVI than CDFI (P < 0.05). Based on high-level blood flow signals (grade 2-3) and hypervascular supply patterns (pattern e and f), the diagnostic accuracy for malignant FLLs were 76% and 68% for MVI, 56% and 38% for CDFI, respectively. CONCLUSION: MVI is superior to CDFI in evaluating vascular architecture of FLLs. The high-level flow signals and hypervascular pattern detected by MVI have a useful and complementary value in preoperative non-invasive identification of malignant FLLs.


Assuntos
Neoplasias Hepáticas , Humanos , Neoplasias Hepáticas/irrigação sanguínea , Estudos Retrospectivos , Fígado/diagnóstico por imagem , Fígado/patologia , Ultrassonografia , Microvasos/diagnóstico por imagem , Sensibilidade e Especificidade , Diagnóstico Diferencial
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...