Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 996
Filtrar
1.
J Vasc Surg Cases Innov Tech ; 10(4): 101522, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38952999

RESUMO

Testicular ischemia is one of the most rarely reported complications of endovascular abdominal aortic aneurysm repair (EVAR). Although the pathogenesis remains unclear, thromboembolic events in the setting of testicular artery origin occlusion by the stent graft and poor baseline collateral testicular circulation are presumed causes. A 73-year-old man developed acute right testicular infarction 3 days after EVAR, requiring orchiectomy. This case emphasizes the importance of recognizing and evaluating testicular pain after EVAR and counseling patients on this possible EVAR complication.

2.
Ann Vasc Surg ; 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38986839

RESUMO

OBJECTIVE: Fusion imaging systems have proved to reduce radiation exposure mostly in hybrid rooms but reports with mobile C-arms are few. The aim of this study was to analyse the impact of the Endonaut® navigation system on radiation exposure in endovascular aneurysm repair (EVAR) performed with mobile C-arms. METHODS: All patients undergoing EVAR and/or iliac branched devices implantation between January 2016 and August 2022 were included. All procedures were performed with a mobile C-arm (Siemens Avantic® or GE Elite® until March 2018, Siemens Cios Alpha® thereafter). The Endonaut® navigation system has been used since January 2021. Two groups were therefore compared : before (control group) and after the use of Endonaut®. Radiation data including Dose Area Product (DAP) values, Air Kerma (AK) and fluoroscopy time (FT) were collected retrospectively. RESULTS: Overall, 153 patients were included: control group (CGr), n = 121; Endonaut® group (EnGr), n = 32. No significant difference was found between the two groups regarding demographic data. DAP values were significantly lower in the EnGr (38 Gy.cm2 ± 24) vs. the CGr (76 Gy.cm2 ± 51) (p<.05) despite a significantly higher number of complex procedures such as iliac branched devices (p<.05). AK values were not significantly different between the EnGr and the CGr (196 mGy ± 114 vs. 209 mGy ± 138) as well as FT (33 minutes ± 18 vs. 33 minutes ± 16). Technical success was 97% (31/32) in the EnGr vs. 96% (116/121) in the CGr (p=.79). The volume of contrast media was significantly lower in the EnGr (94 cc ± 41) vs. the CGr (143 cc ± 66) (p<.05). CONCLUSION: In this study, the use of the Endonaut® angio-navigation system when performing EVAR with mobile C-arms led to a radiation dose reduction without compromising technical success or procedural time.

3.
Cureus ; 16(5): e61420, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38947720

RESUMO

This study highlights a case of late open conversion repair (OCR) for persistent Type II endoleak after endovascular aneurysm repair (EVAR), presenting a 78-year-old male with a history of EVAR for an infrarenal abdominal aortic aneurysm. Despite conservative management of the initial endoleak, the aneurysm sac's progressive growth necessitated open reconstruction to salvage the graft. Successful postoperative outcomes emphasize the critical need for meticulous intervention strategies and surveillance in managing persistent Type II endoleaks. This case underlines the importance of a tailored approach, leveraging both endovascular and open surgical techniques, to optimize long-term outcomes and prevent aneurysm rupture in complex cases.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38824470

RESUMO

PURPOSE: Currently, the intra-operative visualization of vessels during endovascular aneurysm repair (EVAR) relies on contrast-based imaging modalities. Moreover, traditional image fusion techniques lack a continuous and automatic update of the vessel configuration, which changes due to the insertion of stiff guidewires. The purpose of this work is to develop and evaluate a novel approach to improve image fusion, that takes into account the deformations, combining electromagnetic (EM) tracking technology and finite element modeling (FEM). METHODS: To assess whether EM tracking can improve the prediction of the numerical simulations, a patient-specific model of abdominal aorta was segmented and manufactured. A database of simulations with different insertion angles was created. Then, an ad hoc sensorized tool with three embedded EM sensors was designed, enabling tracking of the sensors' positions during the insertion phase. Finally, the corresponding cone beam computed tomography (CBCT) images were acquired and processed to obtain the ground truth aortic deformations of the manufactured model. RESULTS: Among the simulations in the database, the one minimizing the in silico versus in vitro discrepancy in terms of sensors' positions gave the most accurate aortic displacement results. CONCLUSIONS: The proposed approach suggests that the EM tracking technology could be used not only to follow the tool, but also to minimize the error in the predicted aortic roadmap, thus paving the way for a safer EVAR navigation.

5.
Cureus ; 16(5): e60102, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38860102

RESUMO

Limb graft occlusion (LGO) is a common complication that can occur after endovascular aneurysm repair (EVAR). There are many factors that can contribute to LGO, including patient-related variables, device-related considerations, and factors associated with the procedural technique. Patients with LGO may exhibit no symptoms, have intermittent claudication, or suffer from acute limb ischemia. In this manuscript, we present a case of a 64-year-old male who experienced sequential LGOs after EVAR accompanied by a comprehensive review of the pertinent literature.

6.
J Clin Med ; 13(12)2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38930080

RESUMO

Background: Diabetes has a protective effect on abdominal aortic aneurysms (AAAs); however, there are contrasting reports on the impact of diabetes on endovascular aortic repair (EVAR) outcomes, endoleaks (ELs) being the major negative outcome. The present study characterizes ELs and their outcomes in AAA patients, diabetic or not. Methods: This single-center, retrospective, comparative study was carried out on 324 AAA patients who underwent elective EVARs between 2007 and 2016 at the University Hospital of Liège (Belgium). The primary endpoint was the incidence and effect of ELs on the evolution of the aneurysmal sac; the secondary endpoints were surgical reintervention and mortality rate. Diabetic and non-diabetic patients were compared with respect to various risk factors by logistic regression, while a Cox regression was used to analyze survival. Results: In AAA patients meeting the inclusion criteria (n = 248), 23% were diabetic. EL incidence was comparable (p = 0.74) in diabetic (38.7%) vs. non-diabetic (43.9%) patients. EL risk factors were age (HR = 1.04, p = 0.014) and fibrate intake (HR = 3.12, p = 0.043). A significant association was observed between ELs and aneurysm sac enlargement (p < 0.001), regardless of group (p = 0.46). Aneurysm sac regression per month for non-diabetic patients was -0.24 ± 0.013, while for diabetics it was -0.18 ± 0.027 (p = 0.059). Dyslipidemia (HR = 3.01, p = 0.0060) and sulfonylureas (HR = 8.43, p = 0.043) were associated with shorter EL duration, while diabetes (HR = 0.080, p = 0.038) and beta blockers (HR = 0.46, p = 0.036) were associated with longer EL duration. The likelihood of reoperation decreased with more recent surgery (OR = 0.90, p = 0.040), regardless of diabetic status. All-cause mortality was higher for the non-diabetic group (45.5% vs. 26.3%, p = 0.0096). Conclusions: Endoleak occurrence is a known risk factor for sac expansion. In diabetic patients, endoleaks lasted longer, and regression of the aneurysm sac tended to be slower. The number and type of reintervention was not related to the diabetic status of AAA patients, but overall survival was higher in patients with diabetes.

7.
J Vasc Surg ; 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38909915

RESUMO

OBJECTIVES: Aneurysm sac changes after fenestrated-branched endovascular aneurysm repair (FBEVAR) for postdissection thoracoabdominal aortic aneurysms (PD-TAAs) are poorly understood. Partial thrombosis of the false lumen and endoleaks may impair sac regression. To characterize sac changes after FBEVAR for PD-TAAs, this study examined midterm results and predictors for sac enlargement. METHODS: FBEVARs performed for PD-TAAs in 10 physician-sponsored investigational device exemption studies from 2008 to 2023 were analyzed. The maximum aortic aneurysm diameter was compared between the 30-day computed tomography angiogram and follow-up imaging studies. Aneurysm sac enlargement was defined as an increase in diameter of ≥5 mm. Kaplan-Meier curves and Cox regression were used to evaluate sac enlargement and midterm FBEVAR outcomes. RESULTS: Among 3296 FBEVARs, 290 patients (72.4% male; median age, 68.4 years) were treated for PD-TAAs. Most aneurysms treated were extent II (72%) and III (12%). Mean aneurysm diameter was 66.5 ± 11.2 mm. Mortality at 30 days was 1.4%. At a mean follow-up of 2.9 ± 1.9 years, at least one follow-up imaging study revealed sac enlargement in 43 patients (15%), sac regression in 115 patients (40%), and neither enlargement nor regression in 137 (47%); 5 (2%) demonstrated both expansion and regression during follow-up. Freedom from aneurysm sac enlargement was 93%, 82%, and 80% at 1, 3, and 5 years, respectively. Overall, endoleaks were detected in 27 patients (63%) with sac enlargement and 143 patients (58%) without enlargement (P = .54). Sac enlargement was significantly more frequent among older patients (mean age at the index procedure, 70.2 ± 8.9 years vs 66.5 ± 11 years; P = .04) and those with type II endoleaks at 1 year (74% vs 52%; P = .031). Cox regression revealed age >70 years at baseline (hazard ratio [HR], 2.146; 95% confidence interval [CI], 1.167-3.944; P = .010) and presence of type II endoleak at 1 year (HR, 2.25; 95% CI, 1.07-4.79; P = .032) were independent predictors of sac enlargement. Patient survival was 92%, 81%, and 68% at 1, 3, and 5 years, respectively. Cumulative target vessel instability was 7%, and aneurysm-related mortality was 2% at 5 years. At least 42% of patients required secondary interventions. Sac enlargement did not affect patient survival. CONCLUSIONS: Aneurysm sac enlargement occurs in 15% of patients after FBEVAR for PD-TAAs. Elderly patients (>70 years at baseline) and those with type II endoleaks at 1 year may need closer monitoring and secondary interventions to prevent sac enlargement. Despite sac enlargement in some patients, aneurysm-related mortality at 5 years remains low and overall survival was not associated with sac enlargement.

8.
Artigo em Inglês | MEDLINE | ID: mdl-38936689

RESUMO

OBJECTIVE: Numerous articles have reported an increased incidence of limb graft occlusion (LGO) with the Cook Zenith Alpha endograft compared with other endografts in endovascular aortic aneurysm repair (EVAR). The present study aimed to assess the rate of LGO after EVAR in particular with the Cook Zenith Alpha device when adhering to a standardised protocol designed to prevent limb related complications. METHODS: This was a non-sponsored retrospective study performed in two university vascular surgery centres employing the same protocol for limb complication prevention during EVAR from 2016 to 2019. The protocol encompassed: (1) angioplasty of any common/external iliac artery with > 50% stenosis before endograft navigation; (2) proximal sealing zone of limbs at the same level of the flow divider with minimum overlap, which is more restrictive than the Cook Zenith Alpha instructions for use; (3) semicompliant kissing ballooning of limbs; (4) limb stenting in case of any residual tortuosity/kinking/stenosis; and (5) adjunctive common and external iliac stenting for residual stenosis/dissection after EVAR. Patients enrolled in this study were treated with standard aorto-bis-iliac EVAR. Follow up was performed by clinical visit and duplex ultrasonography at discharge, six months, and yearly thereafter. The primary endpoint was to evaluate the LGO rate with different EVAR devices (Cook Zenith Alpha, Gore C3, and Medtronic Endurant) and to determine potential risk factors for LGO associated with the Zenith Alpha. RESULTS: In the study period, 547 EVARs were considered: 233 (42.6%) Cook Zenith Alpha, 196 (35.8%) Gore Excluder, and 118 (21.6%) Medtronic Endurant. The mean follow up was 44 ± 23 months, and the five year freedom from LGO was 97 ± 3%, without differences between groups (97 ± 2%, 95 ± 3%, and 100% with Cook Zenith Alpha, Medtronic Endurant, and Gore Excluder, respectively; p = .080). In the Zenith Alpha group, intra-operative adjunctive iliac artery angioplasty, iliac artery stenting, or iliac limb stenting was performed in 8%, 3.4%, and 9.7%, respectively. Analysis of potential risk factors for LGO identified external iliac artery distal landing and large main bodies (ZIMB 32 - 36) independently associated with LGO during follow up (hazard ratio [HR] 18, 95% confidence interval [CI] 3 - 130, p = .004; and HR 12, 95% CI 1.2 - 130, p = .030, respectively). CONCLUSION: The present experience with a protocol for limb complication prevention allows one to obtain a low rate of LGO at five years with Zenith Alpha endografts similar to other endografts. Specific risk factors for the Cook Zenith Alpha endograft are the external iliac artery distal landing and the use of a large main body (ZIMB 32 - 36).

9.
Ann Vasc Surg ; 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38942365

RESUMO

INTRODUCTION: Late open conversion (LOC) following endovascular aneurysm repair (EVAR) is a rare complication with a high morbidity and mortality and is often proposed as the last line of treatment after failure of endovascular reintervention of any type. This study aimed to highlights the limitations of EVAR follow-up imaging in characterizing endoleaks, which may contribute to the failure of endovascular reinterventions and lead to LOC. METHODS: This retrospective cohort study recruited all EVAR implanted in Amiens University Hospital (France) between January 2008 and December 2022. Elective LOC was defined as surgical conversion > 1 month after EVAR. The primary endpoint was the rate of wrong categorisation of endoleaks by follow-up exams before LOC. Secondary endpoints were the morbidity and the mortality associated with LOC. RESULTS: Seven hundred and eight EVAR were performed in our institution, 30 required elective LOC. Twenty-five of them were treated for sac enlargement due to an endoleak (83,3%) (all types). Wrong categorisation of the endoleak was noted in 13 of the patients (52.2%). Twelve of these re-categorisations involved the preoperative diagnosis of a type II endoleaks (92.3%). The change in categorisation in 7 out of 12 cases (58%) was in favor of a type I endoleak, other re-categorisation included 1 Type III (8%), 4 Types IV (33%). One patient died during 30 days post-operative period and 7 patients (28%) presented a major complication, the median length of stay was 13 days (IQR 9-21). CONCLUSION: Routine follow-up examinations such as angioscanner and contrast Doppler ultrasound appear to be limited in their ability to categorise the type of persistent endoleak, which may increase the number of patients requiring LOC. New precision diagnostic imaging techniques, such as dynamic examinations, need to be developed to limit the need for LOC.

10.
Cureus ; 16(5): e59913, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38854302

RESUMO

Acute aortic occlusions (AAOs) are rare vascular emergencies associated with high morbidity and mortality. Presenting signs and symptoms vary but typically involve the lower extremities and include mottled skin with diminished pedal pulses, paresis, and severe pain. Prompt recognition and imaging are necessary to prevent rapid deterioration, which can lead to loss of limb or death. Treatment includes surgical or endovascular interventions based on patient-associated risk factors and clot location. We present a 76-year-old female who arrived at the emergency department with an AAO involving the infrarenal abdominal aorta and bilateral common iliac arteries. Efficient physical examination and utilization of computed tomography with angiography of the abdomen and pelvis allowed for the appropriate recognition of the AAO and subsequent successful surgical embolectomy. This case report underscores the importance of an expeditious clinical and radiographic evaluation in patients presenting with lower extremity pain and weakness.

11.
Vascular ; : 17085381241262350, 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38872254

RESUMO

OBJECTIVES: A current and ongoing challenge is to reduce patient mortality after endovascular abdominal aortic repair (EVAR). This study aimed to assess the predictors of all-cause mortality after EVAR. METHODS: Data regarding the demographic characteristics, comorbidities, laboratory values, selected anatomical factors, post-EVAR treatment, surveillance and complications of patients who underwent elective EVAR for non-ruptured abdominal aortic aneurysm (AAA) between January 2010 and January 2021 were evaluated. Mortality was assessed until 10 October 2023. Multivariate analyses were performed after adjusting for age, hypertension, diabetes mellitus, dyslipidaemia, sex, smoking, number of lumbar arteries, patency of inferior mesenteric artery (IMA), IMA diameter and reinterventions. RESULTS: This study included 196 patients (183 men and 13 women) with a mean age of 72.4 ± 7.67 years. The overall mortality rate during a mean follow-up period of 5.75 ± 3.1 years was 50.0% (N = 98). The 2-, 5- and 10-year mortality rates were 9.7%, 32.0% and 66.6%, respectively. The mortality rates decreased by 59% in patients with reinterventions (hazard ratio [HR]: 0.41; 95% confidence interval [CI]: 0.23-0.73; p = .002) and by 59% in patients treated with angiotensin-converting enzyme (ACE) inhibitors or angiotensin II receptor blockers (ARBs) (HR: 0.41; 95% CI: 0.26-0.66; p < .001). Chronic anticoagulation was associated with 2.09-fold higher mortality (HR: 2.09; 95% CI: 1.19-3.67; p = .010), and coronary artery disease (CAD) was associated with 1.74-fold higher mortality (HR: 1.74; 95% CI: 1.09-2.78; p = .021). Pre-EVAR AAA diameter and 1-year post-EVAR sac diameter were positively associated with mortality (HR: 1.05; 95% CI: 1.03-1.08; p < .001, and HR: 1.05; 95% CI: 1.03-1.07; p < .001, respectively), that is, an increase of pre-EVAR and/or 1-year post-EVAR AAA diameter by 1 mm was associated with a 5% higher risk of all-cause mortality. CONCLUSIONS: Reinterventions and treatment with ACE inhibitors or ARBs may be associated with decreased post-EVAR mortality. A greater pre-EVAR, a post-EVAR AAA diameter, CAD and chronic anticoagulation were associated with higher all-cause mortality post-EVAR.

12.
Sensors (Basel) ; 24(11)2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38894317

RESUMO

Over the past two decades, there has been extensive research into surveillance methods for the post-endovascular repair of abdominal aortic aneurysms, highlighting the importance of these technologies in supplementing or even replacing conventional image-screening modalities. This review aims to provide an overview of the current status of alternative surveillance solutions for endovascular aneurysm repair, while also identifying potential aneurysm features that could be used to develop novel monitoring technologies. It offers a comprehensive review of these recent clinical advances, comparing new and standard clinical practices. After introducing the clinical understanding of abdominal aortic aneurysms and exploring current treatment procedures, the paper discusses the current surveillance methods for endovascular repair, contrasting them with recent pressure-sensing technologies. The literature on three commercial pressure-sensing devices for post-endovascular repair surveillance is analyzed. Various pre-clinical and clinical studies assessing the safety and efficacy of these devices are reviewed, providing a comparative summary of their outcomes. The review of the results from pre-clinical and clinical studies suggests a consistent trend of decreased blood pressure in the excluded aneurysm sac post-repair. However, despite successful pressure readings from the aneurysm sac, no strong link has been established to translate these measurements into the presence or absence of endoleaks. Furthermore, the results do not allow for a conclusive determination of ongoing aneurysm sac growth. Consequently, a strong clinical need persists for monitoring endoleaks and aneurysm growth following endovascular repair.


Assuntos
Aneurisma da Aorta Abdominal , Procedimentos Endovasculares , Aneurisma da Aorta Abdominal/cirurgia , Humanos , Procedimentos Endovasculares/métodos , Procedimentos Endovasculares/instrumentação , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação , Pressão Sanguínea/fisiologia , Pressão , Próteses e Implantes , Correção Endovascular de Aneurisma
13.
Comput Biol Med ; 178: 108745, 2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38901185

RESUMO

Thoracic endovascular aortic repair (TEVAR) is a minimally invasive procedure involving the placement of an endograft inside the dissection or an aneurysm to direct blood flow and prevent rupture. A significant challenge in endovascular surgery is the geometrical mismatch between the endograft and the artery, which can lead to endoleak formation, a condition where blood leaks between the endograft and the vessel wall. This study uses computational modeling to investigate the effects of artery curvature and endograft oversizing, the selection of an endograft with a larger diameter than the artery, on endoleak creation. Finite element analysis is employed to simulate the deployment of endografts in arteries with varying curvature and diameter. Numerical simulations are conducted to assess the seal zone and to quantify the potential endoleak volume as a function of curvature and oversizing. A theoretical framework is developed to explain the mechanisms of endoleak formation along with proof-of-concept experiments. Two main mechanisms of endoleak creation are identified: local buckling due to diameter mismatch and global buckling due to centerline curvature mismatch. Local buckling, characterized by excess graft material buckling and wrinkle formation, increases with higher levels of oversizing, leading to a larger potential endoleak volume. Global buckling, where the endograft bends or deforms to conform to the centerline curvature of the artery, is observed to require a certain degree of oversizing to bridge the curvature mismatch. This study highlights the importance of considering both curvature and diameter mismatch in the design and clinical use of endografts. Understanding the mechanisms of endoleak formation can provide valuable insights for optimizing endograft design and surgical planning, leading to improved clinical outcomes in endovascular aortic procedures.

14.
CVIR Endovasc ; 7(1): 42, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38700601

RESUMO

BACKGROUND: Preemptive selective embolization of aneurysm sac side branches (ASSBs) has been proposed to prevent type II endoleak after endovascular aortic aneurysm repair (EVAR). This study aimed to explore if an embolization strategy using microvascular plugs (MVP) reduces intervention time and radiation dose compared to platinum-fibered microcoils. Furthermore, the effectiveness of the devices in occluding the treated artery was assessed. METHODS: Sixty patients scheduled for EVAR underwent percutaneous preemptive embolization of ASSBs using MVPs or coils after a 1:1 randomization. Follow-up imaging was performed during aortic stentgraft implantation. RESULTS: Overall, 170 ASSBs were successfully occluded (83 arteries by MVPs and 87 by coils) and no acute treatment failure occurred. The mean procedure time was significantly lower in the group treated with MVPs (55 ± 4 min) compared to coil occlusion (67 ± 3 min; p = 0.018), which was paralleled by a numerically lower radiation dose (119 Gy/cm2 vs. 140 Gy/cm2; p = 0.45). No difference was found for contrast agent use (34 ml MVP group vs 35 ml coil group; p = 0.87). At follow-up, reopening of lumbar arteries was seen in nine cases (four after coil embolization; five after MVPs). CONCLUSION: Both microvascular plugs and coils can be effectively used for preemptive embolization of aneurysm sac side branches before EVAR. Use of plugs offers a benefit in terms of intervention time. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT03842930 Registered 15 February 2019.

15.
J Clin Med ; 13(9)2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38730993

RESUMO

Background: We sought to investigate the differential impact of EVAR (endovascular aneurysm repair) vis-à-vis OSR (open surgical repair) on ruptured AAA (abdominal aortic aneurysm) mortality by sex and geographically. Methods: We performed a retrospective study of administrative data on EVAR from state statistical agencies, vascular registries, and academic publications, as well as ruptured AAA mortality rates from the World Health Organization for 14 14 states across Australasia, East Asia, Europe, and North America. Results: Between 2011-2016, the proportion of treatment of ruptured AAAs by EVAR increased from 26.1 to 43.8 percent among females, and from 25.7 to 41.2 percent among males, and age-adjusted ruptured AAA mortality rates fell from 12.62 to 9.50 per million among females, and from 34.14 to 26.54 per million among males. The association of EVAR with reduced mortality was more than three times larger (2.2 vis-à-vis 0.6 percent of prevalence per 10 percentage point increase in EVAR) among females than males. The association of EVAR with reduced mortality was substantially larger (1.7 vis-à-vis 1.1 percent of prevalence per 10 percentage point increase in EVAR) among East Asian states than European+ states. Conclusions: The increasing adoption of EVAR coincided with a decrease in ruptured AAA mortality. The relationship between EVAR and mortality was more pronounced among females than males, and in East Asian than European+ states. Sex and ethnic heterogeneity should be further investigated.

16.
J Clin Med ; 13(9)2024 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-38731118

RESUMO

Aim: To assess the medium and long-term performance of the Endurant stent graft in a cohort of consecutive patients treated with this device for an abdominal aortic aneurysm (AAA) both inside and outside of the instructions for use (IFU) and to find factors influencing the outcomes. Methods: Our observational, retrospective, single-center study included all patients who consecutively underwent endovascular aneurysm repair with the Endurant stent graft from February 2009 to January 2023. Patients with an AAA to treat according to current guidelines were included. Patients were divided into two groups: Group 1 inside of the IFUs and Group 2 outside of the IFUs for the proximal aortic neck. Patients were followed up after the procedure with computed angiography tomography, ultrasound examination, and interviews. Aneurysm-related mortality, procedure-related reinterventions, and type IA and III endoleaks were considered primary endpoints. Secondary endpoints included aneurysmal sac variations and graft thrombosis. Results: A total of 795 patients were included, 650 in Group 1 and 145 in Group 2; 732 were males, and the mean age was 74 ± 8. Anamnestic baseline did not differ between the two groups. Neck length, width, and angulation were different between the two groups (all p < 0.001). A total of 40 patients had a ruptured AAA, while 56 were symptomatic. At a mean follow-up of 43 ± 39 months, aneurysm-related mortality was less than 1%, and 82 endoleak (10.5%) were observed. Overall endoleak rate and type 1A endoleak, as well as procedure-related reintervention, were significantly more frequent in Group 2. Sac regression of at least 5 mm was observed in 65.9% of cases. AAAs larger than 60.5 mm carried a higher risk of endoleak (HR: 1.025; 95% CI: 1.013-1.37; p < 0.001) and proximal necks shorter than 13.5 mm carried a higher type 1A risk (HR: 0.890; 95% CI: 0.836-0.948; p < 0.001). Patients without chronic obstructive pulmonary disease and taking lipid-lowering drugs had an overall more consistent sac-shrinking rate. Conclusions: The Endurant stent graft proves safe and reliable. Out-of-IFU treatment has poorer medium and long-term outcomes. Some conditions influence medium and long-term reintervention risk and sac behavior. Patients with bigger aneurysms, proximal necks shorter than 13.5 mm, and chronic obstructive pulmonary disease should be more carefully evaluated during follow-up. Consistent follow-up is in keeping low aneurysm-related mortality. Personalized risk profiles and peri and postoperative management strategies are needed.

17.
Diagnostics (Basel) ; 14(9)2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38732344

RESUMO

OBJECTIVES: Surveillance after endovascular aortic repair (EVAR) and fenestrated EVAR (FEVAR) is mainly directed by one-size-fits-all approaches instead of personalized decision making, even though treatment strategies and often endografts themselves are tailor-made to adjust for individual patients. We propose a modular imaging algorithm that escalates surveillance imaging based on invasiveness and need. MATERIALS AND METHODS: In this retrospective observational study of single-center data, results of a modular imaging algorithm were analyzed. The algorithm is characterized by initiating the examination with standard B-mode then transitioning to Duplex ultrasound, B-Flow, and CEUS. Additional CT(A) studies are conducted where required. The study population included both patients receiving EVAR or FEVAR. A comparative analysis was conducted regarding endoleak detection. RESULTS: The study population included 28 patients receiving EVAR and 40 patients receiving FEVAR. They accounted for 101 follow-up visits, which led to 431 distinct imaging studies. CEUS has the highest endoleak detection rate, followed by CTA and B-Flow. Duplex ultrasound and B-Flow resulted in 0 and 1 false positive cases, respectively, considering CEUS the reference standard. In a select group of six patients, CEUS was omitted after endoleaks were displayed by Duplex ultrasound or B-Flow, leading to a successful type II coiling and no aneurysm-related adverse events. CONCLUSIONS: The proposed modular algorithm showed great potential to incorporate principles of personalized medicine in surveillance after endovascular aortic treatment. Since Duplex ultrasound and B-Flow rarely cause false positive endoleaks, more resource-intensive and invasive imaging studies such as CEUS and CTA can be omitted after positive identification.

18.
Cureus ; 16(4): e57707, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38711730

RESUMO

We discuss a rare case of Stanford type A aortic dissection (TAAD) occurring several months after endovascular aneurysm repair (EVAR) of the abdominal aortic and the common iliac artery (CIA) aneurysms. The patient underwent urgent surgery for TAAD treatment but died on the table due to intractable bleeding. We conclude that TAAD was likely unrelated to the initial EVAR procedure but rather to atherosclerosis, hypertension, and prior aortic valve replacement. Only a few cases in the literature report TAAD and total collapse of the abdominal aortic stent graft.

19.
J Endovasc Ther ; : 15266028241248345, 2024 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-38733297

RESUMO

OBJECTIVES: Type I and III endoleaks following endovascular aneurysm repair (EVAR) can lead to catastrophic events that require major re-interventions. We reviewed our experience with aortic endograft re-interventions for type I and III endoleaks and other serious failures among different devices. METHODS: We retrospectively reviewed patients with a prior EVAR who underwent open conversion (OC) or major endovascular intervention (MEI) (re-lining, cuff/limb extension, parallel graft) for type I/III endoleaks at our institution from 2002 to 2019. Baseline characteristics, procedural details, re-interventions, and outcomes were collected. RESULTS: A total of 229 patients (194 men) underwent re-interventions for type I and III endoleaks after EVAR (90 OC, 139 MEI) for devices implanted between 1997 and 2019. Average age at re-intervention was 78±8.5 years. A total of 135 (59%) were implanted at our institution, whereas 93 (41%) were referred. Median time to re-intervention was 4 years with 25% to 75% interquartile range (IQR) of 2.2-6.6 years. There was no significant difference in baseline demographics or type of re-interventions (OC/MEI) between device types. 42/229 (18%) presented with ruptured aneurysms, 20/229 (9%) were symptomatic, whereas the rest presented with asymptomatic radiographic findings. Type 1A endoleak was present in 146/229 (63.8%-72 with proximal migration), type IB in 46/229 (20.1%), type IIIA in 37/229 (16.6%), type IIIB in 15/229 (6.5%), and persistent aneurysm sac growth with no radiographic evidence of an endoleak in 6/229 (2.6%). Devices included most commercial products: AFX, Excluder, AneuRx, Ancure, Endurant, and Zenith. A smaller number of investigational devices accounted for the rest. Type 1A endoleak was the most common indication for re-intervention among all devices except for AFX and ancure devices, proximal migration was a frequent presentation with AneuRx. AFX devices more frequently presented with a type III and ancure devices more frequently presented with a type IB endoleak. CONCLUSIONS: Serious failure modes after EVAR differ between endografts and occur throughout the follow-up period. This is important to guide targeted interrogation of surveillance studies and follow-up schedules, even for discontinued devices, as well as comparisons between various series and estimation of EVAR failure rates. CLINICAL IMPACT: Surveillance after EVAR is critical for long term success of the repair, understanding of the differential modes of failure of every graft available is important in the longitudinal evaluation of these endografts. Equally important is the understanding of the modes of failure of legacy endografts that are no longer on the market but still being followed, in order to be able to tailor a surveillance regiemn and the evntual repair if needed.

20.
Surg Case Rep ; 10(1): 124, 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38750283

RESUMO

BACKGROUND: Cases of abdominal aortic aneurysm discovered as purpura on the extremities with disseminated intravascular coagulation (DIC) are rare. The number of currently established strategies for the control of DIC with aortic aneurysm is limited. CASE PRESENTATION: An 85-year-old woman was referred to the hematology department because of purpura on her shoulder and thigh. Enhanced fibrinolytic-type DIC was diagnosed by a blood test. Enhanced computed tomography (CT) revealed 60-mm abdominal aortic and 42-mm right common iliac aneurysms. We performed endovascular aneurysm repair (EVAR) and coiling of the right internal iliac artery with postoperative administration of Nafamostat mesylate. The patient promptly recovered from DIC, and the purpura gradually disappeared. CONCLUSIONS: We safely performed EVAR with postoperative administration of Nafamostat mesylate for an abdominal aortic aneurysms that presented as symptomatic DIC.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...