Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 685
Filtrar
1.
Front Physiol ; 15: 1382982, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38860113

RESUMO

Objectives: To compare the inter-rectus distance (IRD), rectus abdominis thickness (RAT), and stiffness in women during pregnancy and postpartum and identify the risk and protective factors affecting diastasis recti abdominis (DRA). Materials and methods: A total of 171 pregnant women who volunteered to participate in this study were recruited. Using an ultrasonographic diagnostic instrument with shear wave elastography function, IRD, RAT and the Young's modulus of the rectus abdominis muscles were measured at 12 weeks, 37 weeks of pregnancy, and 6 weeks postpartum. Results: The IRD at 37 weeks was significantly higher than that at 12 weeks and then decreased at 6 weeks postpartum, but it was still higher than that at 12 weeks (p < 0.001). RAT and Young's modulus decreased significantly at 37 weeks compared with those at 12 weeks and then recovered at 6 weeks postpartum, but they were lower than those at 12 weeks (p < 0.001). IRD at 12 weeks was significantly higher in multiparae than in primiparae (p < 0.001). Moreover, positive correlation between the RAT and Young's modulus of rectus abdominis muscles at 12 and 37 weeks of gestation and 6 weeks postpartum (p < 0.001) was observed. Multiple linear regression analysis showed that the regression equation was significant (f = 24.856, p < 001). Conclusion: Our study identified differences in IRD, thickness and stiffness of the rectus abdominis muscle between early and advanced pregnancy and the postpartum period. The risk and protective factors of DRA may guide pregnant women's protection and treatment.

2.
J Magn Reson Imaging ; 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38855820

RESUMO

BACKGROUND: Preoperative differentiation of the types of mediastinal tumors is essential. Magnetic resonance (MR) elastography potentially provides a noninvasive method to assess the classification of mediastinal tumor subtypes. PURPOSE: To evaluate the use of MR elastography in anterior mediastinal masses and to characterize the mechanical properties of tumors of different subtypes. STUDY TYPE: Prospective. SUBJECTS: 189 patients with anterior mediastinal tumors (AMTs) confirmed by histopathology (62 thymomas, 53 thymic carcinomas, 57 lymphomas, and 17 germ cell tumors). FIELD STRENGTH/SEQUENCE: A gradient echo-based 2D MR elastography sequence and a diffusion-weighted imaging (DWI) sequence at 3.0 T. ASSESSMENT: Stiffness and apparent diffusion coefficients (ADC) were measured in AMTs using MR elastography-derived elastograms and DWI-derived ADC maps, respectively. The aim of this study is to identify whether MR elastography can differentiate between the histological subtypes of ATMs. STATISTICAL TESTS: One-way analysis of variance (ANOVA), two-way ANOVA, Pearson's linear correlation coefficient (r), receiver operating characteristic (ROC) curve analysis; P < 0.05 was considered significant. RESULTS: Lymphomas had significantly lower stiffness than other AMTs (4.0 ± 0.63 kPa vs. 4.8 ± 1.39 kPa). The mean stiffness of thymic carcinomas was significantly higher than that of other AMTs (5.6 ± 1.41 kPa vs. 4.2 ± 0.94 kPa). Using a cutoff value of 5.0 kPa, ROC analysis showed that lymphomas could be differentiated from other AMTs with an accuracy of 59%, sensitivity of 97%, and specificity of 38%. Using a cutoff value of 5.1 kPa, thymic carcinomas could be differentiated from other AMTs with an accuracy of 84%, sensitivity of 67%, and specificity of 90%. However, there was an overlap in the stiffness values of individual thymomas (4.2 ± 0.71; 3.9-4.5), thymic carcinomas (5.6 ± 1.41; 5.0-6.1), lymphomas (4.0 ± 0.63; 3.8-4.2), and germ cell tumors (4.5 ± 1.79; 3.3-5.6). DATA CONCLUSION: MR elastography-derived stiffness may be used to evaluate AMTs of various histologies. TECHNICAL EFFICACY: Stage 2.

3.
Pediatr Radiol ; 54(7): 1144-1155, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38772925

RESUMO

BACKGROUND: Non-invasive imaging modalities are warranted for diagnosing and monitoring veno-occlusive disease because early diagnosis and treatment improve the prognosis. OBJECTIVE: To evaluate the usefulness of liver shear wave elastography (SWE) and shear wave dispersion (SWD) imaging in diagnosing and monitoring veno-occlusive disease in pediatric patients. MATERIALS AND METHODS: We conducted a prospective cohort study at a single tertiary hospital from March 2021 to April 2022. The study protocol included four ultrasound (US) sessions: a baseline US and three follow-up US after hematopoietic stem cell transplantation. Clinical criteria, including the European Society for Blood and Marrow Transplantation criteria, were used to diagnose veno-occlusive disease. We compared clinical factors and US parameters between the veno-occlusive disease and non-veno-occlusive disease groups. The diagnostic performance of US parameters for veno-occlusive disease was assessed by plotting receiver operating characteristic (ROC) curves. We describe temporal changes in US parameters before and after veno-occlusive disease diagnosis. RESULTS: Among the 38 participants (mean age 10.7 years), eight developed veno-occlusive disease occurring 17.0 ± 5.2 days after hematopoietic stem cell transplantation. Liver stiffness, as measured by SWE (15.0 ± 6.2 kPa vs. 5.8 ± 1.8 kPa; P<0.001), and viscosity, as assessed with SWD (17.7 ± 3.1 m/s/kHz vs. 14.3 ± 2.8 m/s/kHz; P=0.015), were significantly higher in the veno-occlusive disease group compared to the non-veno-occlusive disease group at the time of diagnosis. Liver stiffness demonstrated the highest area under the ROC (AUROC) curves at 0.960, with an optimal predictive value of >6.5 kPa, resulting in sensitivity and specificity of 100% and 83.3%, respectively. Viscosity demonstrated an AUROC of 0.783, with an optimal cutoff value of 13.9 m/s/kHz for predicting veno-occlusive disease, with a sensitivity of 100% and specificity of 53.3%, respectively. Liver stiffness increased with disease severity and decreased during post-treatment follow-up. CONCLUSION: SWE may be a promising technique for early diagnosis and severity prediction of veno-occlusive disease. Furthermore, liver viscosity assessed by SWD may serve as an additional marker of veno-occlusive disease.


Assuntos
Técnicas de Imagem por Elasticidade , Estudos de Viabilidade , Transplante de Células-Tronco Hematopoéticas , Hepatopatia Veno-Oclusiva , Humanos , Técnicas de Imagem por Elasticidade/métodos , Hepatopatia Veno-Oclusiva/diagnóstico por imagem , Hepatopatia Veno-Oclusiva/etiologia , Masculino , Feminino , Criança , Estudos Prospectivos , Pré-Escolar , Adolescente , Valor Preditivo dos Testes
4.
Exp Ther Med ; 27(6): 259, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38756898

RESUMO

The present retrospective study was designed to explore the value of conventional ultrasound (US) and Virtual Touch Tissue Imaging and Quantification (VTIQ) in the assessment of mesenteric lymphadenitis (ML) in a paediatric population. A total of 103 patients with ML and 60 healthy paediatric patients were examined. VTIQ was performed to assess mesenteric lymph node (MLN) stiffness via shear-wave velocity (SWV). Univariate and multivariate logistic regression analyses were conducted to reveal independent variables for the identification of ML. The diagnostic performance of US, and US combined with VTIQ, were compared. All the quantitative VTIQ parameters (including the SWVMean, SWVMax and SWVMin) were significantly greater for MLNs in the control group than for MLNs in the ML group (all P<0.001). The SWV values in the control group were nearly 2-fold greater than that in the ML group. According to the multivariate logistic regression analysis, the longest diameter [odds ratio (OR)=6.042; P=0.046] was revealed to be the strongest independent predictor for ML, followed by the CRP level (OR=2.310; P<0.001) and the SWVMean (OR=0.106; P<0.001). According to the receiver operating characteristic analysis, the area under the curve (AUC) for US combined with VTIQ was 0.890 (95% CI: 0.831-0.949) with a greater sensitivity of 91.26% and a greater specificity of 86.67% than that for US alone (AUC: 0.798; 95% CI: 0.724-0.872; sensitivity: 79.61%; specificity: 80.00%). A significant negative correlation between increased VTIQ parameters and ML was observed. Utilizing VTIQ to assess MLN stiffness offers a non-invasive, convenient, reliable and reproducible approach for identifying mesenteric lymphadenopathy.

5.
J Clin Ultrasound ; 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38708803

RESUMO

We explore the use of shear wave elastography (SWE) for assessing muscle stiffness and treatment response in cerebral palsy (CP) children by way of a systematic review. SWE offers real-time muscle stiffness measurements, showing significant differences between CP patients and controls. Studies suggest that SWE can be used to follow muscle stiffness post-botulinum toxin treatment, correlating with clinical improvement. However, methodological variations and small sample sizes prevent comparison between different studies. Standardized protocols could enhance SWE's clinical utility. In conclusion, SWE holds promise for CP management, though standardized methodologies and larger studies are needed to validate its efficacy and integration into clinical practice.

6.
Clinics (Sao Paulo) ; 79: 100381, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38733689

RESUMO

OBJECTIVES: The primary objective was to evaluate Liver-Related Events (LREs), including hepatic decompensation (ascites, hemorrhagic varices and encephalopathy) and Hepatocellular Carcinoma (HCC), as well as changes in liver stiffness during the follow-up period among patients who achieved a Sustained Virological Response (SVR) after treatment for chronic Hepatitis C Virus (HCV) infection. METHODS: A total of 218 patients with HCV were treated, and those who achieved an SVR were followed up for 3-years. Transient Elastography (TE) using FibroScan® was performed at various time points: before treatment, at the end of treatment, at 6-months post-treatment, at 1-year post-treatment, at 2-years post-treatment, and at 3-years post-treatment. RESULTS: At 6-months post-treatment, a Liver Stiffness Measurement (LSM) cutoff of > 19 KPa was identified, leading to a 14.5-fold increase in the hazard of negative outcomes, including decompensation and/or HCC. The analysis of relative changes in liver stiffness between pre-treatment and 6-months posttreatment revealed that a reduction in LSM of -10 % was associated with a -12 % decrease in the hazard of decompensation and/or HCC, with this trend continuing as the LSM reduction reached -40 %, resulting in a -41 % hazard of decompensation and/or HCC. Conversely, an increase in the relative change during this period, such as an LSM increase of +10 %, led to a + 14 % increase in the hazard of decompensation. In cases where this relative change in LSM was +50 %, the hazard of decompensation increased to +92. CONCLUSION: Transient elastography using FibroScan® can be a good tool for monitoring HCV patients with SVR after treatment to predict LREs in the long term.


Assuntos
Antivirais , Carcinoma Hepatocelular , Técnicas de Imagem por Elasticidade , Hepatite C Crônica , Cirrose Hepática , Neoplasias Hepáticas , Resposta Viral Sustentada , Humanos , Técnicas de Imagem por Elasticidade/métodos , Masculino , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/virologia , Feminino , Pessoa de Meia-Idade , Hepatite C Crônica/tratamento farmacológico , Hepatite C Crônica/complicações , Hepatite C Crônica/diagnóstico por imagem , Antivirais/uso terapêutico , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/virologia , Seguimentos , Fatores de Tempo , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/virologia , Resultado do Tratamento , Adulto , Idoso , Valor Preditivo dos Testes
7.
Quant Imaging Med Surg ; 14(4): 3033-3043, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38617167

RESUMO

Background: The pathological Johnsen score (JS) is a quantitative histological scoring system used to assess spermatogenesis in men with nonobstructive azoospermia (NOA), while elastic modulus derived from shear wave elastography (SWE) is a diagnostic tool for evaluating spermatogenic dysfunction. In this prospective observational study, we aimed to investigate whether testicular stiffness measured by SWE could serve as a substitute for JS in predicting sperm retrieval outcomes in men with NOA. Methods: This prospective cohort study analyzed 140 testes from 115 consecutive outpatient participants with NOA who had sought treatment at the reproductive medical center of a tertiary care hospital between January 2018 and October 2021. Testicular volume, elastic modulus, JS, and sperm retrieval outcomes were calculated. Statistical differences in parameters between the positive and negative sperm retrieval groups were determined using the Mann-Whitney test. Spearman rank correlation analysis was performed to determine the correlations between JS and either testicular volumes or elastic modulus. Receiver operating characteristic (ROC) curves were drawn to evaluate the diagnostic performance of the testicular elastic modulus and testicular volume. Results: The JS correlated positively with testicular volume and negatively with the maximum elastic modulus (Emax) and mean elastic modulus (Emean), with correlation coefficients of 0.804, -0.686, and -0.456, respectively (P<0.01). There were significant differences in JS, testicular volume, and Emax between participants with positive and negative sperm retrieval of microdissection testicular sperm extraction (micro-TESE) (P<0.01). ROC curves were plotted for JS, testicular volume, and Emax to distinguish between participants with positive and negative sperm retrieval. The areas under the ROC curves (AUCs) were 0.783 [95% confidence interval (CI): 0.707-0.859; P<0.01], 0.737 (95% CI: 0.651-0.823; P<0.01), and 0.729 (95% CI: 0.643-0.814; P<0.01), respectively. When the cutoff value of JS was 4.5, its sensitivity and specificity were 60.3% and 89.6%, respectively. When the cutoff value of Emax was 3.75 kPa, its sensitivity and specificity were 79.1% and 64.4%, respectively. The sensitivity and specificity were 68.5% and 83.6%, respectively when the cutoff value of testicular volume was 8.17 mL. Emax combined with testicular volume improved this diagnostic value, with an AUC of 0.742 (95% CI: 0.657-0.828; P<0.01), and sensitivity and specificity were 83.6% and 68.5%, respectively. Conclusions: Our study suggests that the combination of testicular stiffness and volume measurements may serve as a viable alternative to pathological JS in predicting the likelihood of successful sperm retrieval prior to micro-TESE procedures.

8.
Artigo em Inglês | MEDLINE | ID: mdl-38613718

RESUMO

PURPOSE: Shear wave velocity (SWV) is an ultrasound elastography technique that provides much information for kidney disease assessment. However, the factors that alter SWV are not fully understood; it is unclear whether the variation in SWV seen in proteinuria associated with disease progression is due to tissue or proteinuria. This study investigated the effect of proteinuria on SWV. METHODS: This prospective observational study compared SWV at remission with SWV at relapse in children treated for idiopathic nephrotic syndrome (INS) between April 2020 and December 2023. All relapses without oral steroids during the observation period were measured. SWV at remission was defined as the date closest to relapse during which repeated measurements were taken approximately every 3 months after steroid discontinuation. RESULTS: Eight patients were treated for INS with a median observation period of 21.9 months (11.8-27.1). Of the 15 relapses, five that met the definition were considered for the study. The median interval between the measurement at relapse and remission was 40 days (11-55). SWV was significantly lower at relapse than remission (2.40 ± 0.20 m/s vs. 2.14 ± 0.15 m/s, P < 0.01). CONCLUSIONS: SWV decreased in the presence of severe proteinuria at relapse compared to the remission measurements. Although more cases need to be studied, the decrease in SWV may reflect the mechanism by which protein leaks into the urine, not just a direct change caused by the presence of proteinuria.

9.
Abdom Radiol (NY) ; 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38557769

RESUMO

PURPOSE: This study was conducted to investigate the effectiveness of strain elastography in guiding precise and sufficient tissue sampling for perihilar cholangiocarcinoma (CCA) biopsies. METHODS: Our retrospective analysis included 23 liver biopsies conducted between March 2019 and July 2022 for suspected perihilar CCA. An experienced radiologist performed the biopsies via an ultrasound machine with elastography configuration. Tissue stiffness color maps were used for guiding when the biopsies were performed. Strain index value calculations were made by radiologists on recorded images. RESULTS: Patient demographics revealed a mean age of 65.17 ± 9.25 years, with a gender distribution of six females and 17 males. Gray-scale examinations unveiled diverse echogenic characteristics in liver lesions. Elastography-guided biopsies demonstrated no need for repeats, while gray-scale biopsies necessitated re-biopsy in four patients, resulting in cholangiocarcinoma diagnosis (P = 0.037). Strain index values showcased strong inter- and intra-observer agreements (P < 0.001). Notably, no post-biopsy complications emerged in either study group. CONCLUSION: The diagnostic advantage of elastography, particularly in enhancing accuracy in challenging isoechoic lesions, was demonstrated, although the substantial overlap between strain index values of benign and malignant liver masses limits clinical usefulness of this technique.

10.
Diagnostics (Basel) ; 14(7)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38611672

RESUMO

Intestinal ultrasound is a non-invasive, safe, and cost-effective technique to study the small and large intestines. In addition to conventional B-mode and color doppler imaging, new US tools have been developed in more recent years that provide auxiliary data on many GI conditions, improving the diagnosis and assessment of relevant outcomes. We have reviewed the more recent literature (from 2010 onwards) on auxiliary tools in bowel ultrasound such as elastography techniques, CEUS, SICUS, and the potential contribution by artificial intelligence (AI) to overcome current intestinal ultrasound limitations. For this scoping review, we performed an extensive literature search on PubMed and EMBASE to identify studies published until December 2023 and investigating the application of elastography techniques, CEUS, SICUS, and AI in the ultrasonographic assessment of the small and large intestines. Multiparametric intestinal ultrasound shows promising capabilities in Crohn's disease, while less is known about the role in ulcerative colitis. Despite some evidence, the CEUS role as a point-of-care examination tool for rare conditions such as intestinal GvHD and ischemic small bowel disease seems promising, possibly avoiding the need to perform further cross-sectional imaging. The use of AI in intestinal ultrasound is still anecdotical and limited to acute appendicitis.

11.
Abdom Radiol (NY) ; 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38642092

RESUMO

PURPOSE: To assess liver and spleen characteristics of a population with Gaucher disease (GD) using multiparametric MRI and MR elastography (MRE) for evaluation of diffuse liver and spleen disease, which includes liver fat fraction, liver and spleen volume and iron deposition, and liver and spleen stiffness correlated with DS3 Severity Scoring System for Gaucher disease (GD-DS3). METHODS: We prospectively evaluated 41 patients with type 1 Gaucher disease using a 3.0 T MRI and MRE between January 2019 and February 2020. Clinical, laboratory, and imaging data was collected. Mann-Whitney, Kruskal-Wallis, and Spearman's correlation were applied to evaluate liver and spleen MRI and MRE, clinical and laboratory variables, and GD-DS3. ERT and SRT treatment groups were compared. RESULTS: Hepatomegaly was seen in 15% and splenomegaly in 42% of the population. Moderate and strong and correlations were found between liver and spleen iron overload (rho = 0.537; p = 0.002); between liver and spleen volume (rho = 0.692, p < 0.001) and between liver and spleen stiffness (rho = 0.453, p = 0.006). Moderate correlations were found between liver stiffness and GD-DS3 (rho = 0.559; p < 0.001) and between splenic volume and GD-DS3 (rho = 0.524; p = 0.001). CONCLUSION: The prevalence of hepatosplenomegaly, liver fibrosis, and liver iron overload in treated patients with GD is low, which may be related to the beneficial effect of treatment. Liver MRE and splenic volume correlate with severity score and may be biomarkers of disease severity.

12.
Magn Reson Imaging ; 109: 173-179, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38484948

RESUMO

BACKGROUND: Increasing evidence has indicated that high tissue stiffness (TS) may be a potential biomarker for evaluation of tumor aggressiveness. PURPOSE: To investigate the value of magnetic resonance elastography (MRE)-based quantitative parameters preoperatively predicting the tumor grade and subtype of cervical cancer (CC). STUDY TYPE: Retrospective. POPULATION: Twenty-five histopathology-proven CC patients and 7 healthy participants. FIELD STRENGTH/SEQUENCE: 3.0T, magnetic resonance imaging (MRI) (LAVA-flex) and MRE with a three-dimensional spin-echo echo-planar imaging. ASSESSMENT: The regions of interest (ROIs) were manually drawn by two observers in tumors to measure mean TS, storage modulus (G'), loss modulus (G″) and damping ratio (DR) values. Surgical specimens were evaluated for tumor grades and subtypes. STATISTICAL TESTS: Intraclass correlation coefficient (ICC) was expressed in terms of inter-observer agreements. t-test or Mann-Whitney nonparametric test was used to compare the complex modulus and apparent diffusion coefficient (ADC) values between different tumor groups. Area under the receiver operating characteristic curve (AUC) analysis was used to evaluate the diagnostic performance. RESULTS: The TS of endocervical adenocarcinoma (ECA) group was significantly higher than that in squamous cell carcinoma (SCC) group (5.27 kPa vs. 3.44 kPa, P = 0.042). The TS also showed significant difference between poorly and well/moderately differentiated CC (5.21 kPa vs. 3.47 kPa, P = 0.038), CC patients and healthy participants (4.18 kPa vs. 1.99 kPa, P < 0.001). The cutoff value of TS to discriminate ECA from SCC was 4.10 kPa (AUC: 0.80), while it was 4.42 kPa to discriminate poorly from well/moderately differentiated CC (AUC: 0.83), and 2.25 kPa to distinguish normal cervix from CC (AUC: 0.88), respectively. There were no significant difference in G″, DR and ADC values between any subgroups except for comparison of healthy participants and CC patients (P = 0.001, P = 0.004, P < 0.001, respectively). DATA CONCLUSION: 3D MRE-assessed TS shows promise as a potential biomarker to preoperatively assess tumor grade and subtype of CC.


Assuntos
Técnicas de Imagem por Elasticidade , Neoplasias do Colo do Útero , Feminino , Humanos , Técnicas de Imagem por Elasticidade/métodos , Estudos Retrospectivos , Neoplasias do Colo do Útero/diagnóstico por imagem , Imageamento por Ressonância Magnética , Biomarcadores
13.
J Clin Ultrasound ; 52(5): 511-521, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38465504

RESUMO

PURPOSE: To explore the diagnostic value of intralesional and perilesional radiomics based on multimodal ultrasound (US) images in predicting the malignant ACR TIRADS 4 thyroid nodules (TNs). METHODS: A total of 297 cases of TNs in patients who underwent preoperative thyroid grayscale US and shear wave elastography (STE) were enrolled (training cohort: n = 150, internal validation cohort: n = 77, external validation cohort: n = 70). Regions of interests (ROIs) were delineated on grayscale US images and STE images, and then an isotropic expansion of 1.0, 1.5, 2.0, 2.5, and 3.0 mm was applied. Predictive models were established using recursive feature elimination-support vector machines (RFE-SVM) based on radiomics features calculated by random forest. RESULTS: The perilesional ROI1.5mm expansion achieved the highest area under curve (AUC) (AUC: 0.753 for grayscale US, 0.728 for STE; 95% confidence interval (CI): 0.664-0.743, 0.684-0.739, respectively). The joint model had the highest AUC values of 0.936 in the training dataset, 0.926 in internal dataset, and 0.893 in external dataset. The calibration curve showed good consistency and the decision curve indicated a greater clinical net benefit of the joint model. CONCLUSION: Joint model containing perilesional radiomics (1.5 mm) had significant value in predicting the malignant ACR TIRADS 4 TNs.


Assuntos
Nódulo da Glândula Tireoide , Ultrassonografia , Humanos , Nódulo da Glândula Tireoide/diagnóstico por imagem , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Ultrassonografia/métodos , Técnicas de Imagem por Elasticidade/métodos , Glândula Tireoide/diagnóstico por imagem , Valor Preditivo dos Testes , Estudos Retrospectivos , Imagem Multimodal/métodos , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Idoso , Reprodutibilidade dos Testes , Radiômica
14.
Magn Reson Imaging ; 109: 127-133, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38513784

RESUMO

PURPOSE: Magnetic resonance elastography (MRE) is a noninvasive tool for diagnosing hepatic fibrosis with high accuracy. We investigated the preoperative clinical and imaging predictors of intrahepatic recurrence after curative resection of hepatocellular carcinoma (HCC), and evaluated MRE as a predictor of intrahepatic recurrence. METHODS: We retrospectively evaluated 80 patients who underwent preoperative contrast-enhanced magnetic resonance imaging (MRI) with two-dimensional MRE and curative resection for treatment-naïve HCC between May 2019 and December 2021. Liver stiffness (LS) was measured on the elastograms, and the optimal cutoff of LS for predicting intrahepatic recurrence was obtained using receiver operating characteristic (ROC) analysis. An LS above this cutoff was defined as MRE-recurrence. Preoperative imaging features of the tumor were assessed on MRI, including features in the Liver Imaging Reporting and Data System and microvascular invasion (MVI). Recurrence-free survival (RFS) rates were estimated using the Kaplan-Meier method, and differences were compared using the log-rank test. Using a Cox proportional hazards model, we conducted a multivariable analysis to investigate the factors affecting recurrence-free survival. RESULTS: During a median follow-up period of 32 months (range, 4-52 months), thirteen patients (16.3%) developed intrahepatic recurrence. ROC analysis determined an LS cutoff of ≥4.35 kPa to define MRE-recurrence. The 4-year RFS rate was significantly higher in patients without MRE-recurrence than in those with MRE-recurrence (93.4% vs. 48.9%; p = 0.001). In multivariable analysis, MRE-recurrence (Hazard ratio [HR], 5.9; 95% confidence interval [CI], 1.5-23.1) and MVI (HR, 3.4; 95% CI, 1.0-11.3) were independent predictors of intrahepatic recurrence. CONCLUSIONS: Patients without MRE-recurrence had significantly higher RFS rates than those with MRE-recurrence. MRE-recurrence and MVI were independent predictors of intrahepatic recurrence in patients after curative resection for HCC.


Assuntos
Carcinoma Hepatocelular , Técnicas de Imagem por Elasticidade , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/cirurgia , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/patologia , Técnicas de Imagem por Elasticidade/métodos , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos
15.
Acad Radiol ; 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38508938

RESUMO

RATIONALE AND OBJECTIVES: To compare urethral stricture shear wave elastography (SWE) with normal areas and assess its association with other explanatory variables. SUBJECTS AND METHODS: we recruited all men with urethral stricture disease referred to our center between December 2021 and July 2023. Patients underwent SWE and elasticity in the stricture area, and one and three centimeters distant from the stricture were measured. Gathered data were analyzed using Freidman and post hoc analysis, correlation methods, student t-tests, and one-way ANOVA. RESULTS: 22 patients were recruited for our study. Spongiofibrosis was significantly higher in the stricture area relative to the one-centimeter-distant adjacent area (p < .0005), in the one-centimeter-distant compared to the three-centimeter-distant area (p = .002), and in the stricture area relative to the three-centimeter-distant area (p < .0005). There was no association between elasticity ratio and patient age or stricture location. Likewise, there was no difference in elasticity ratios between bulbar and pendulous strictures (p = 0.19) or among different etiologies of urethral strictures (p = 0.76). CONCLUSION: There is a significant difference in elasticity between the urethral stricture area and other parts of the corpus spongiosum. Normal areas closer to strictures are stiffer. The elasticity ratio is unrelated to patient age or prior internal urethromies. Neither stricture locations nor distinct urethral stricture etiologies differed in elasticity ratios.

16.
Muscle Nerve ; 69(6): 682-690, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38517116

RESUMO

INTRODUCTION/AIMS: Carriers of DMD pathogenic variants may become symptomatic and develop muscle-related manifestations. Despite that, few studies have attempted to characterize changes in the muscles of these carriers using imaging tools, particularly muscle ultrasound (MUS). The aim of this study was to compare lower limb MUS findings in carriers of DMD pathogenic variants (cDMD) vs healthy controls. METHODS: Twenty-eight women (15 cDMD and 13 controls) underwent clinical evaluation and MUS. We collected information about muscle-related symptoms and assessed muscle strength. MUS was performed by a single physician (blind to the genetic status of subjects). The following muscles were assessed: rectus femoris, sartorius, tibialis anterior, and medial gastrocnemius. For each site, we computed data on muscle thickness, cross-sectional area, sound attenuation index, and elastography. Between-group comparisons were assessed using nonparametric tests and p-values <.05 were deemed significant. RESULTS: None of the subjects had objective muscle weakness, but exercise intolerance/fatigue was reported by four cDMDs and only one control. Regarding MUS, sound attenuation indices were significantly higher among carriers for all muscles tested. Longitudinal and axial deep echo intensities for the rectus femoris and tibialis anterior were also higher in the cDMD group compared with controls. No significant between-group differences were noted for elastography values, muscle area, or mean echo intensities. DISCUSSION: cDMD have skeletal muscle abnormalities that can be detected using quantitative MUS. Further studies are needed to determine whether such abnormalities are related to muscle symptoms in these patients.


Assuntos
Músculo Esquelético , Distrofia Muscular de Duchenne , Ultrassonografia , Humanos , Feminino , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiopatologia , Adulto , Distrofia Muscular de Duchenne/diagnóstico por imagem , Distrofia Muscular de Duchenne/genética , Distrofia Muscular de Duchenne/fisiopatologia , Adulto Jovem , Pessoa de Meia-Idade , Distrofina/genética , Heterozigoto , Adolescente , Força Muscular/fisiologia
17.
J Viral Hepat ; 31(6): 277-292, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38326950

RESUMO

Non-invasive methods have largely replaced biopsy to identify advanced fibrosis in hepatitis C virus (HCV). Guidelines vary regarding testing strategy to balance accuracy, costs and loss to follow-up. Although individual test characteristics are well-described, data comparing the accuracy of using two tests together are limited. We calculated combined test characteristics to determine the utility of combined strategies. This study synthesizes empirical data from fibrosis staging trials and the literature to estimate test characteristics for Fibrosis-4 (FIB4), APRI or a commercial serum panel (FibroSure®), followed by transient elastography (TE) or FibroSure®. We simulated two testing strategies: (1) second test only for those with intermediate first test results (staged approach), and (2) second test for all. We summarized empiric data with multinomial distributions and used this to estimate test characteristics of each strategy on a simulated population of 10,000 individuals with 4.2% cirrhosis prevalence. Negative predictive value (NPV) for cirrhosis from a single test ranged from 98.2% (95% CB 97.6-98.8%) for FIB-4 to 99.4% (95% CB 99.0-99.8%) for TE. Using a staged approach with TE second, sensitivity for cirrhosis rose to 93.3-96.9%, NPV to 99.7-99.8%, while PPV dropped to <32%. Using TE as a second test for all minimally changed estimated test characteristics compared with the staged approach. Combining two non-invasive fibrosis tests barely improves NPV and decreases or does not change PPV compared with a single test, challenging the utility of serial testing modalities. These calculated combined test characteristics can inform best methods to identify advanced fibrosis in various populations.


Assuntos
Técnicas de Imagem por Elasticidade , Cirrose Hepática , Humanos , Cirrose Hepática/diagnóstico , Cirrose Hepática/patologia , Cirrose Hepática/virologia , Técnicas de Imagem por Elasticidade/métodos , Sensibilidade e Especificidade , Hepatite C Crônica/complicações , Hepatite C Crônica/patologia , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Masculino , Feminino , Hepatite C/diagnóstico , Hepatite C/complicações , Pessoa de Meia-Idade
18.
Sensors (Basel) ; 24(2)2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38257632

RESUMO

Shore hardness (SH) is a cost-effective and easy-to-use method to assess soft tissue biomechanics. Its use for the plantar soft tissue could enhance the clinical management of conditions such as diabetic foot complications, but its validity and reliability remain unclear. Twenty healthy adults were recruited for this study. Validity and reliability were assessed across six different plantar sites. The validity was assessed against shear wave (SW) elastography (the gold standard). SH was measured by two examiners to assess inter-rater reliability. Testing was repeated following a test/retest study design to assess intra-rater reliability. SH was significantly correlated with SW speed measured in the skin or in the microchamber layer of the first metatarsal head (MetHead), third MetHead and rearfoot. Intraclass correlation coefficients and Bland-Altman plots of limits of agreement indicated satisfactory levels of reliability for these sites. No significant correlation between SH and SW elastography was found for the hallux, 5th MetHead or midfoot. Reliability for these sites was also compromised. SH is a valid and reliable measurement for plantar soft tissue biomechanics in the first MetHead, the third MetHead and the rearfoot. Our results do not support the use of SH for the hallux, 5th MetHead or midfoot.


Assuntos
Ossos do Metatarso , Adulto , Humanos , Fenômenos Biomecânicos , Dureza , Reprodutibilidade dos Testes , Pé/diagnóstico por imagem
19.
Cancers (Basel) ; 16(2)2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38254866

RESUMO

Shear-wave elastography (SWE) is an effective tool in discriminating malignant lesions of breast and axillary lymph node metastasis in patients with breast cancer. However, the association between the baseline elasticity value of breast cancer and the treatment response of neoadjuvant chemotherapy is yet to be elucidated. Baseline SWE measured mean stiffness (E-mean) and maximum stiffness (E-max) in 830 patients who underwent neoadjuvant chemotherapy and surgery from January 2012 to December 2022. Association of elasticity values with breast pCR (defined as ypTis/T0), pCR (defined as ypTis/T0, N0), and tumor-infiltrating lymphocytes (TILs) was analyzed. Of 830 patients, 356 (42.9%) achieved breast pCR, and 324 (39.0%) achieved pCR. The patients with low elasticity values had higher breast pCR and pCR rates than those with high elasticity values. A low E-mean (adjusted odds ratio (OR): 0.620; 95% confidence interval (CI): 0.437 to 0.878; p = 0.007) and low E-max (adjusted OR: 0.701; 95% CI: 0.494 to 0.996; p = 0.047) were independent predictive factors for breast pCR. Low elasticity values were significantly correlated with high TILs. Pretreatment elasticity values measured using SWE were significantly associated with treatment response and inversely correlated with TILs, particularly in HR+HER2- breast cancer and TNBC.

20.
Orthop Traumatol Surg Res ; 110(1): 103647, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37356798

RESUMO

BACKGROUND: The objective of this study was to evaluate the stiffness of the anterior talo-fibular ligament (ATFL) and calcaneo-fibular ligament (CFL) using shear wave elastography (SWE) with the ankle in the neutral position and in varus, in young healthy adult volunteers. We also evaluated the reliability and reproducibility of the SWE measurements. HYPOTHESIS: The stiffness of both ligaments increases with increasing ankle varus. SWE may be a reliable tool for evaluating the lateral collateral ligament complex of the ankle. MATERIAL AND METHODS: We used SWE to evaluate both ankles of each of 20 healthy volunteers (10 females and 10 males). For each test, the foot was placed on a hinged plate and tested in the neutral position and in 15° and 30° of varus. Stiffness was evaluated based on shear wave velocity (SWV). RESULTS: Stiffness of both the ATFL and CFL was minimal in the neutral position (2.06m/s and 3.43m/s, respectively). Stiffness increased significantly for both ligaments in 15° of varus (2.48m/s and 4.11m/s, respectively; p<0.0001) and was greatest in 30° of varus (3.15m/s and 4.57m/s, respectively; p<0.0001). ATFL stiffness was greater in males than in females in 15° (p=0.04) and 30° (p=0.02) of varus. For the CFL, in contrast, stiffness was not different between males and females. Stiffness of the ATFL and CFL was not associated with age, dominant side, height, or foot morphology. No correlations were found between stiffness of the two ligaments in any of the positions. Repeating each measurement three times produced excellent concordance for both ligaments in all three positions. CONCLUSION: The ATFL and CFL are the main lateral stabilisers of the ankle, and each exerts a specific function. Their stiffness increases with the degree of varus. This study describes a protocol for evaluating ATFL and CFL density by SWE, which is a reliable and reproducible technique that provides a normal range. LEVEL OF EVIDENCE: IV.


Assuntos
Técnicas de Imagem por Elasticidade , Instabilidade Articular , Ligamentos Laterais do Tornozelo , Masculino , Adulto , Feminino , Humanos , Ligamentos Laterais do Tornozelo/diagnóstico por imagem , Reprodutibilidade dos Testes , Cadáver , Articulação do Tornozelo/diagnóstico por imagem , Ligamentos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...