Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
J Cardiothorac Surg ; 19(1): 397, 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38937763

RESUMO

OBJECTIVES: Current recommendations support surgical treatment of atrial fibrillation (AF) in patients indicated for cardiac surgery. These procedures are referred to as concomitant and may be carried out using radiofrequency energy or cryo-ablation. This study aimed to assess the electrophysiological findings in patients undergoing concomitant cryo-ablation. METHODS: Patients with non-paroxysmal AF undergoing coronary artery bypass grafting and/or valve repair/replacement were included in the trial if concomitant cryo-ablation was part of the treatment plan according to current guidelines. The patients reported in this study were assigned to undergo staged percutaneous radiofrequency catheter ablation (PRFCA), i.e., hybrid treatment, as a part of the SURHYB trial protocol. RESULTS: We analyzed 103 patients who underwent PRFCA 105 ± 35 days after surgery. Left and right pulmonary veins (PVs) were found isolated in 65 (63.1%) and 63 (61.2%) patients, respectively. The LA posterior wall isolation and mitral isthmus conduction block were found in 38 (36.9%) and 18 (20.0%) patients, respectively. Electrical reconnections (gaps) in the left PVs were more often localized superiorly than inferiorly (57.9% vs. 26.3%, P = 0.005) and anteriorly than posteriorly (65.8% vs. 31.6%, P = 0.003). Gaps in the right PVs were more equally distributed anteroposteriorly but dominated in superior segments (72.5% vs. 40.0%, P = 0.003). There was a higher number of gaps on the roof line compared to the inferior line (131 (67.2%) vs. 67 (42.2%), P < 0.001). Compared to epicardial cryo-ablation, endocardial was more effective in creating PVs and LA posterior wall isolation (P < 0.05). Cryo-ablation using nitrous oxide (N20) or argon (Ar) gas as cooling agents was similarly effective (P = NS). CONCLUSIONS: The effectiveness of surgical cryo-ablation in achieving transmural and durable lesions in the left atrium is surprisingly low. Gaps are located predominantly in the superior and anterior portions of the PVs and on the roof line. Endocardial cryo-ablation is more effective than epicardial ablation, irrespective of the cooling agent used.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Masculino , Feminino , Ablação por Cateter/métodos , Pessoa de Meia-Idade , Idoso , Veias Pulmonares/cirurgia , Resultado do Tratamento , Ponte de Artéria Coronária/métodos
3.
Adv Sci (Weinh) ; 10(31): e2304978, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37661571

RESUMO

Reversible switching of room-temperature electrical resistivity due to crystal-amorphous transition is demonstrated in various chalcogenides for development of non-volatile phase change memory. However, such reversible thermal switching of room-temperature electrical resistivity has not reported in transition metal oxides so far, despite their enormous studies on the electrical conduction like metal-insulator transition and colossal magnetoresistance effect. In this study, a thermally reversible switching of room-temperature electrical resistivity is reported with gigantic variation in a layered nickelate Sr2.5 Bi0.5 NiO5 (1201-SBNO) composed of (Sr1.5 Bi0.5 )O2 rock-salt and SrNiO3 perovskite layers via unique crystalline phase changes between the conducting 1201-SBNO with ordered (O-1201), disordered Sr/Bi arrangements in the (Sr1.5 Bi0.5 )O2 layer (D-1201), and insulating oxygen-deficient double perovskite Sr2 BiNiO4.5 (d-perovskite). The O-1201 is reentrant by high-temperature annealing of ≈1000 °C through crystalline phase change into the D-1201 and d-perovskite, resulting in the thermally reversible switching of room-temperature electrical resistivity with 102 - and 109 -fold variation, respectively. The 1201-SBNO is the first oxide to show the thermally reversible switching of room-temperature electrical resistivity via the crystalline phase changes, providing a new perspective on the electrical conduction for transition metal oxides.

4.
Int J Mol Sci ; 24(16)2023 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-37628714

RESUMO

The heart is one of the major organs affected by microwave radiation, and these effects have been extensively studied. Previous studies have shown that microwave-radiation-induced heart injury might be related to the abnormal expression and distribution of Cx43. In order to make the research model closer to humans, we used iPSC-CMs as the cell injury model to investigate the biological effect and mechanism of iPSC-CM injury after microwave radiation. To model the damage, iPSC-CMs were separated into four groups and exposed to single or composite S-band (2.856 GHz) and X-band (9.375 GHz) microwave radiation sources with an average power density of 30 mW/cm2. After that, FCM was used to detect cell activity, and ELISA was used to detect the contents of myocardial enzymes and injury markers in the culture medium, and it was discovered that cell activity decreased and the contents increased after radiation. TEM and SEM showed that the ultrastructure of the cell membrane, mitochondria, and ID was damaged. Mitochondrial function was aberrant, and glycolytic capacity decreased after exposure. The electrical conduction function of iPSC-CM was abnormal; the conduction velocity was decreased, and the pulsation amplitude was reduced. Wb, qRT-PCR, and IF detections showed that the expression of Cx43 was decreased and the distribution of Cx43 at the gap junction was disordered. Single or composite exposure to S- and X-band microwave radiation caused damage to the structure and function of iPSC-CMs, primarily affecting the cell membrane, mitochondria, and ID. The composite exposure group was more severely harmed than the single exposure group. These abnormalities in structure and function were related to the decreased expression and disordered distribution of Cx43.


Assuntos
Conexina 43 , Células-Tronco Pluripotentes Induzidas , Humanos , Conexina 43/genética , Micro-Ondas/efeitos adversos , Membrana Celular , Meios de Cultura
5.
Nanomaterials (Basel) ; 13(15)2023 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-37570498

RESUMO

Activation energy, bipolar resistance switching behavior, and the electrical conduction transport properties of ITOX:SiO2 thin film resistive random access memory (RRAM) devices were observed and discussed. The ITOX:SiO2 thin films were prepared using a co-sputtering deposition method on the TiN/Si substrate. For the RRAM device structure fabrication, an Al/ITOX:SiO2/TiN/Si structure was prepared by using aluminum for the top electrode and a TiN material for the bottom electrode. In addition, grain growth, defect reduction, and RRAM device performance of the ITOX:SiO2 thin film for the various oxygen gas flow conditions were observed and described. Based on the I-V curve measurements of the RRAM devices, the turn on-off ratio and the bipolar resistance switching properties of the Al/ITOX:SiO2/TiN/Si RRAM devices in the set and reset states were also obtained. At low operating voltages and high resistance values, the conductance mechanism exhibits hopping conduction mechanisms for set states. Moreover, at high operating voltages, the conductance mechanism behaves as an ohmic conduction current mechanism. Finally, the Al/ITOX:SiO2/TiN/Si RRAM devices demonstrated memory window properties, bipolar resistance switching behavior, and nonvolatile characteristics for next-generation nonvolatile memory applications.

6.
Materials (Basel) ; 16(5)2023 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-36903112

RESUMO

In the present work, we report that the manufacturing of new environmentally friendly and low-cost materials with electrical conductivity can be roughly and finely tuned by an external magnetic field for technical and biomedical applications. With this aim in mind, we prepared three types of membranes based on cotton fabric impregnated with bee honey, carbonyl iron microparticles (CI), and silver microparticles (SmP). In order to study the influence of the metal particles and the magnetic field on the electrical conductivity of membranes, electrical devices were made. Using the "volt-amperometric" method, it was found that the electrical conductivity of the membranes is influenced by the mass ratio (mCI: mSmP) and by the B values of the magnetic flux density. It was observed that in the absence of an external magnetic field, adding microparticles of carbonyl iron mixed with silver microparticles in mass ratios (mCI: mSmP) of 1:0, 1:0.5, and 1:1 causes the electrical conductivity of the membranes based on cotton fabrics impregnated with honey to increase 2.05, 4.62, and 7.52 times, respectively, compared with that of the membrane based on cotton fabrics impregnated with honey alone. When applying a magnetic field, the electrical conductivity of the membranes with microparticles of carbonyl iron and silver increases with increasing magnetic flux density B. We conclude that the membranes are very good candidates for the fabrication of devices to be used in biomedical applications due to the possibility of remote, magnetically induced release of the bioactive compounds from honey and silver microparticles into the area of interest during medical treatment.

7.
Materials (Basel) ; 16(4)2023 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-36837202

RESUMO

We have investigated the structural, magnetic, and electrical transport properties of Pr0.7 Sr0.3 Mn(1-x)Cox O3 nanopowders (x = 0, 0.05, 0.10 and 0.15). The Pechini Sol-gel method was used to synthesize these nanopowders. X-ray diffraction at room temperature shows that all the nano powders have an orthorhombic structure of Pnma space group crystallography. The average crystallite size of samples x = 0, 0.05, 0.10, and 0.15 are 33.78 nm, 29 nm, 33.61 nm, and 24.27 nm, respectively. Semi-quantitative chemical analysis by energy dispersive spectroscopy (EDS) confirms the expected stoichiometry of the sample. Magnetic measurements indicate that all samples show a ferromagnetic (FM) to paramagnetic (PM) transition with increasing temperature. The Curie temperature TC gradually decreases (300 K, 270 K, 250 K, and 235 K for x = 0, 0.05, 0.10, and 0.15, respectively) with increasing Co concentrations. The M-H curves for all compounds reveal the PM behavior at 300 K, while the FM behavior characterizes the magnetic hysteresis at low temperature (5 K). The electrical resistivity measurements show that all compounds exhibit metallic behavior at low temperature (T < Tρ) well fitted by the relation ρ = ρ0 + ρ2T2 + ρ4.5T4.5 and semiconductor behavior above Tρ (T > Tρ), for which the electronic transport can be explained by the variable range hopping model and the adiabatic small polaron hopping model. All samples have significant magnetoresistance (MR) values, even at room temperature. This presented research provides an innovative and practical approach to develop materials in several technological areas, such as ultra-high density magnetic recording and magneto resistive sensors.

8.
Microcirculation ; 30(1): e12797, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36577656

RESUMO

OBJECTIVE: Endothelial cell (EC) coupling occurs through gap junctions and underlies cerebral blood flow regulation governed by inward-rectifying K+ (KIR ) channels. This study addressed effects of KIR channel activity on EC coupling before and during Alzheimer's disease (AD). METHODS: Intact EC tubes (width: ~90-100 µm; length: ~0.5 mm) were freshly isolated from posterior cerebral arteries of young Pre-AD (1-3 months) and aged AD (13-18 months) male and female 3xTg-AD mice. Dual intracellular microelectrodes applied simultaneous current injections (±0.5-3 nA) and membrane potential (Vm ) recordings in ECs at distance ~400 µm. Elevated extracellular potassium ([K+ ]E ; 8-15 mmol/L; reference, 5 mmol/L) activated KIR channels. RESULTS: Conducted Vm (∆Vm ) responses ranged from ~-30 to 30 mV in response to -3 to +3 nA (linear regression, R2 ≥ .99) while lacking rectification for charge polarity or axial direction of spread. Conduction slope decreased ~10%-20% during 15 mmol/L [K+ ]E in Pre-AD males and AD females. 15 mmol/L [K+ ]E decreased conduction by ~10%-20% at lower ∆Vm thresholds in AD animals (~±20 mV) versus Pre-AD (~±25 mV). AD increased conducted hyperpolarization by ~10%-15% during 8-12 mmol/L [K+ ]E . CONCLUSIONS: Brain endothelial KIR channel activity modulates bidirectional spread of vasoreactive signals with enhanced regulation of EC coupling during AD pathology.


Assuntos
Doença de Alzheimer , Masculino , Feminino , Animais , Camundongos , Células Endoteliais/metabolismo , Junções Comunicantes/metabolismo , Endotélio Vascular/metabolismo , Potenciais da Membrana
9.
J Interv Card Electrophysiol ; 66(5): 1269-1277, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36525171

RESUMO

BACKGROUND: Radiofrequency catheter ablation (RFCA) is widely used to treat arrhythmias. However, for atrial fibrillation, the recurrence rate after RFCA is still high. The development of an animal model that mimics the recurrence of electrical conduction after ablation is essential before we can explore the mechanisms involved or develop new therapeutic strategies. METHODS: Eighteen beagles aged 12 to 24 months were randomly assigned to this study. RFCA ablation of the right atrial free wall was performed. Then, electrical block and conduction recovery in the ablation area were evaluated using voltage mapping and pacing tests assisted by CARTO3 system. Finally, liposome doxorubicin (DOX-L) was intravenously injected after ablation to investigate the effect of DOX-L on this animal model. RESULTS: The conduction block (CB) rates at 5 min after ablation were 16.7%, 83.3%, and 100%, corresponding to 30w, 35w, and 40w power, respectively. However, after 20 min, the rate of CB was 0%, 33.3%, and 75%; thus, the combined success rate of CB and conduction recurrence was 16.7%, 50%, and 25%, respectively. The optimal ablation parameter is 35 W for 20 s, based on the CB rate, REC rate. After 10 days of ablation, the residual conduction recurrence rate was as high as 83.3% in the RFCA alone group, whereas there was no recurrence with RFCA combined with DOX-L treatment. CONCLUSIONS: The novel model accurately simulated the electrical conduction recurrence after cardiac radiofrequency ablation. RFCA combined with DOX-L treatment dramatically reduces the recurrence rate of electrical conduction after ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Animais , Cães , Fibrilação Atrial/cirurgia , Doxorrubicina , Átrios do Coração/cirurgia , Frequência Cardíaca , Resultado do Tratamento
10.
Adv Mater ; 35(6): e2208409, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36380720

RESUMO

Ultralow-k materials used in high voltage devices require mechanical resilience and electrical and dielectric stability even when subjected to mechanical loads. Existing devices with organic polymers suffer from low thermal and mechanical stability while those with inorganic porous structures struggle with poor mechanical integrity. Recently, 3D hollow-beam nanolattices have emerged as promising candidates that satisfy these requirements. However, their properties are maintained for only five stress cycles at strains below 25%. Here, we demonstrate that alumina nanolattices with different relative density distributions across their height elicit a deterministic mechanical response concomitant with a 1.5-3.3 times higher electrical breakdown strength than nanolattices with uniform density. These density-variant nanolattices exhibit an ultralow-k of ≈1.2, accompanied by complete electric and dielectric stability and mechanical recoverability over 100 cyclic compressions to 62.5% strain. We explain the enhanced insulation and long-term cyclical stability by the bi-phase deformation where the lower-density region protects the higher-density region as it is compressed before the higher-density region, allowing to simultaneously possess high strength and ductility like composites. This study highlights the superior electrical performance of the bi-phase nanolattice with a single interface in providing stable conduction and maximum breakdown strength.

11.
Materials (Basel) ; 15(17)2022 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-36079193

RESUMO

In this work, Gd/Mn co-doped CaBi4Ti4O15 Aurivillius-type ceramics with the formula of Ca1-xGdxBi4Ti4O15 + xGd/0.2wt%MnCO3 (abbreviated as CBT-xGd/0.2Mn) were prepared by the conventional solid-state reaction route. Firstly, the prepared ceramics were identified as the single CaBi4Ti4O15 phase with orthorhombic symmetry and the change in lattice parameters detected from the Rietveld XRD refinement demonstrated that Gd3+ was successfully substituted for Ca2+ at the A-site. SEM observations further revealed that all samples were composed of the randomly orientated plate-like grains, and the corresponding average grain size gradually decreased with Gd content (x) increasing. For all compositions studied, the frequency independence of conductivity observed above 400 °C showed a nature of ionic conduction behavior, which was predominated by the long-range migration of oxygen vacancies. Based on the correlated barrier hopping (CBH) model, the maximum barrier height WM, the dc conduction activation energy Edc, as well as the hopping conduction activation energy Ep were calculated for the CBT-xGd/0.2Mn ceramics. The composition with x = 0.06 was found to have the highest Edc value of 1.87 eV, as well as the lowest conductivity (1.8 × 10-5 S/m at 600 °C) among these compositions. The electrical modules analysis for this composition further illustrated the degree of interaction between charge carrier ß increases, with an increase in temperature from 500 °C to 600 °C, and then a turn to decrease when the temperature exceeded 600 °C. The value of ß reached a maximum of 0.967 at 600 °C, indicating that the dielectric relaxation behavior at this temperature was closer to the ideal Debye type.

12.
Front Physiol ; 13: 843421, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35250642

RESUMO

INTRODUCTION: Cardiac pacing has been an effective treatment in the management of patients with bradyarrhythmia and tachyarrhythmia. Different pacemaker location has different responses, and pacemaker effectiveness to each individual can also be different. A novel image-based ventricle animal modeling approach was proposed to optimize ventricular pacemaker site for better cardiac outcome. METHOD: One health female adult pig (weight 42.5 kg) was used to make a pacing animal model with different ventricle pacing locations. Ventricle surface electric signal, blood pressure and echo image were acquired 15 min after the pacemaker was implanted. Echo-based left ventricle fluid-structure interaction models were constructed to perform ventricle function analysis and investigate impact of pacemaker location on cardiac outcome. With the measured electric signal map from the pig associated with the actual pacemaker site, electric potential conduction of myocardium was modeled by material stiffening and softening in our model, with stiffening simulating contraction and softening simulating relaxation. Ventricle model without pacemaker (NP model) and three ventricle models with the following pacemaker locations were simulated: right ventricular apex (RVA model), posterior interventricular septum (PIVS model) and right ventricular outflow tract (RVOT model). Since higher peak flow velocity, flow shear stress (FSS), ventricle stress and strain are linked to better cardiac function, those data were collected for model comparisons. RESULTS: At the peak of filling, velocity magnitude, FSS, stress and strain for RVOT and PIVS models were 13%, 45%, 18%, 13% and 5%, 30%, 10%, 5% higher than NP model, respectively. At the peak of ejection, velocity magnitude, FSS, stress and strain for RVOT and PIVS models were 50%, 44%, 54%, 59% and 23%, 36%, 39%, 53% higher than NP model, respectively. RVA model had lower velocity, FSS, stress and strain than NP model. RVOT model had higher peak flow velocity and stress/strain than PIVS model. It indicated RVOT pacemaker site may be the best location. CONCLUSION: This preliminary study indicated that RVOT model had the best performance among the four models compared. This modeling approach could be used as "virtual surgery" to try various pacemaker locations and avoid risky and dangerous surgical experiments on real patients.

13.
Chinese Journal of Anesthesiology ; (12): 1103-1107, 2022.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-957574

RESUMO

Objective:To evaluate the effects of exosomes derived from cardiac fibroblasts pretreated with sevoflurane on ventricular electrical conduction in isolated rat hearts subjected to hypothermic ischemia-reperfusion (I/R) using the multi-electrode array mapping technique.Methods:Primary cardiac fibroblasts were extracted by differential adhesion in SPF Sprague-Dawley rats of either sex.Cardiac fibroblasts of passage 2-4 were treated with 2.5% sevoflurane for 1 h, and then cultured for 24-48 h to extract exosome.SPF healthy male Sprague-Dawley rats, aged 2-3 months, weighing 280-320 g, were divided into 3 groups ( n=8 each) using a random number table method: control group (group C), I/R group and sevoflurane-pretreated cardiac fibroblast-derived exosome+ IR group (group S+ IR). Hearts were perfused for 110-min equilibration in group C. After 20 min of equilibration, the perfusion was suspended for 60 min (global ischemia) followed by 30 min of reperfusion in IR and S+ IR groups.Exosomes 1 ml (200 μg) derived from cardiac fibroblasts pretreated with sevoflurane were injected through the tail vein at 48 h before surgery in group S+ IR, and the equal volume of normal saline was injected instead in C and IR groups.The cardiac conduction velocity (CV), conduction absolute inhomogeneity (P 5-95) and inhomogeneity index (P 5-95/P 50) were obtained at 20 min of equilibration (T 0) and 15 and 30 min of reperfusion (T 1, 2) using the microelectrode array attaching to the left ventricular surface of the isolated heart. Results:Compared with group C, CV was significantly decreased and P 5-95 and P 5-95/P 50 were increased at T 1 ( P<0.05), and no significant change was found at T 2 in group S+ IR ( P>0.05), and CV was significantly decreased and P 5-95 and P 5-95/P 50 were increased at T 1, 2 in group IR ( P<0.05). Compared with group IR, CV was significantly increased and P 5-95 and P 5-95/P 50 were decreased at T 1, 2 in group S+ IR ( P<0.05). Conclusions:Exosomes derived from cardiac fibroblasts pretreated with sevoflurane can improve ventricular electrical conduction in isolated rat hearts subjected to hypothermic I/R.

14.
Materials (Basel) ; 14(19)2021 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-34639995

RESUMO

In this work, a kind of Gd/Cr codoped Bi3TiNbO9 Aurivillius phase ceramic with the formula of Bi2.8Gd0.2TiNbO9 + 0.2 wt% Cr2O3 (abbreviated as BGTN-0.2Cr) was prepared by a conventional solid-state reaction route. Microstructures and electrical conduction behaviors of the ceramic were investigated. XRD and SEM detection found that the BGTN-0.2Cr ceramic was crystallized in a pure Bi3TiNbO9 phase and composed of plate-like grains. A uniform element distribution involving Bi, Gd, Ti, Nb, Cr, and O was identified in the ceramic by EDS. Because of the frequency dependence of the conductivity between 300 and 650 °C, the electrical conduction mechanisms of the BGTN-0.2Cr ceramic were attributed to the jump of the charge carriers. Based on the correlated barrier hopping (CBH) model, the maximum barrier height WM, dc conduction activation energy Ec, and hopping conduction activation energy Ep were calculated with values of 0.63 eV, 1.09 eV, and 0.73 eV, respectively. Impedance spectrum analysis revealed that the contribution of grains to the conductance increased with rise in temperature; at high temperatures, the conductance behavior of grains deviated from the Debye relaxation model more than that of grain boundaries. Calculation of electrical modulus further suggested that the degree of interaction between charge carriers ß tended to grow larger with rising temperature. In view of the approximate relaxation activation energy (~1 eV) calculated from Z″ and M″ peaks, the dielectric relaxation process of the BGTN-0.2Cr ceramic was suggested to be dominated by the thermally activated motion of oxygen vacancies as defect charge carriers. Finally, a high piezoelectricity of d33 = 18 pC/N as well as a high resistivity of ρdc = 1.52 × 105 Ω cm at 600 °C provided the BGTN-0.2Cr ceramic with promising applications in the piezoelectric sensors with operating temperature above 600 °C.

15.
Front Physiol ; 12: 730933, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34675817

RESUMO

With an estimated 64.3 million cases worldwide, heart failure (HF) imposes an enormous burden on healthcare systems. Sudden death from arrhythmia is the major cause of mortality in HF patients. Computational modeling of the failing heart provides insights into mechanisms of arrhythmogenesis, risk stratification of patients, and clinical treatment. However, the lack of a clinically informed approach to model cardiac tissues in HF hinders progress in developing patient-specific strategies. Here, we provide a microscopy-based foundation for modeling conduction in HF tissues. We acquired 2D images of left ventricular tissues from HF patients (n = 16) and donors (n = 5). The composition and heterogeneity of fibrosis were quantified at a sub-micrometer resolution over an area of 1 mm2. From the images, we constructed computational bidomain models of tissue electrophysiology. We computed local upstroke velocities of the membrane voltage and anisotropic conduction velocities (CV). The non-myocyte volume fraction was higher in HF than donors (39.68 ± 14.23 vs. 22.09 ± 2.72%, p < 0.01), and higher in ischemic (IC) than nonischemic (NIC) cardiomyopathy (47.2 ± 16.18 vs. 32.16 ± 6.55%, p < 0.05). The heterogeneity of fibrosis within each subject was highest for IC (27.1 ± 6.03%) and lowest for donors (7.47 ± 1.37%) with NIC (15.69 ± 5.76%) in between. K-means clustering of this heterogeneity discriminated IC and NIC with an accuracy of 81.25%. The heterogeneity in CV increased from donor to NIC to IC tissues. CV decreased with increasing fibrosis for longitudinal (R 2 = 0.28, p < 0.05) and transverse conduction (R 2 = 0.46, p < 0.01). The tilt angle of the CV vectors increased 2.1° for longitudinal and 0.91° for transverse conduction per 1% increase in fibrosis. Our study suggests that conduction fundamentally differs in the two etiologies due to the characteristics of fibrosis. Our study highlights the importance of the etiology-specific modeling of HF tissues and integration of medical history into electrophysiology models for personalized risk stratification and treatment planning.

16.
Materials (Basel) ; 14(9)2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34062754

RESUMO

Hydrogenated amorphous carbon (a-C:H) films have optical and electrical properties that vary widely depending on deposition conditions; however, the electrical conduction mechanism, which is dependent on the film structure, has not yet been fully revealed. To understand the relationship between the film structure and electrical conduction mechanism, three types of a-C:H films were prepared and their film structures and electrical properties were evaluated. The sp2/(sp2 + sp3) ratios were measured by a near-edge X-ray absorption fine structure technique. From the conductivity-temperature relationship, variable-range hopping (VRH) conduction was shown to be the dominant conduction mechanism at low temperatures, and the electrical conduction mechanism changed at a transition temperature from VRH conduction to thermally activated band conduction. On the basis of structural analyses, a model of the microstructure of a-C:H that consists of sp2 and sp3-bonded carbon clusters, hydrogen atoms and dangling bonds was built. Furthermore, it is explained how several electrical conduction parameters are affected by the carrier transportation path among the clusters.

17.
ACS Nano ; 15(2): 2791-2799, 2021 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-33556241

RESUMO

Realizing switchable n-type and p-type conduction in bismuth selenide (Bi2Se3), a traditional thermoelectric material and a topological insulator, is highly beneficial for the development of thermoelectric devices and also of great interest for spintronics and quantum computing. In this work, switching between n-type and p-type conduction in single Bi2Se3 nanoribbons is achieved by a reversible copper (Cu) intercalation method. Density functional theory calculations reveal that such a switchable behavior arises from the electronic band structure distortion caused by the high-concentration Cu intercalation and the Cu substitution for Bi sites in the host lattice. A proof-of-concept in-plane thermoelectric generator is fabricated with one pair of the pristine n-type and intercalated p-type Bi2Se3 nanoribbons on a microfabricated device, which gives rise to an open-circuit voltage of 4.8 mV and a maximum output power of 0.3 nW under a temperature difference of 29.2 K. This work demonstrates switchable n-type and p-type electrical conduction in Bi2Se3 nanoribbons via a facile chemical approach and the practical application of nanoribbons in a thermoelectric device.

18.
Neural Regen Res ; 16(9): 1829-1835, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33510090

RESUMO

The study illustrates that graphene oxide nanosheets can endow materials with continuous electrical conductivity for up to 4 weeks. Conductive nerve scaffolds can bridge a sciatic nerve injury and guide the growth of neurons; however, whether the scaffolds can be used for the repair of spinal cord nerve injuries remains to be explored. In this study, a conductive graphene oxide composited chitosan scaffold was fabricated by genipin crosslinking and lyophilization. The prepared chitosan-graphene oxide scaffold presented a porous structure with an inner diameter of 18-87 µm, and a conductivity that reached 2.83 mS/cm because of good distribution of the graphene oxide nanosheets, which could be degraded by peroxidase. The chitosan-graphene oxide scaffold was transplanted into a T9 total resected rat spinal cord. The results show that the chitosan-graphene oxide scaffold induces nerve cells to grow into the pores between chitosan molecular chains, inducing angiogenesis in regenerated tissue, and promote neuron migration and neural tissue regeneration in the pores of the scaffold, thereby promoting the repair of damaged nerve tissue. The behavioral and electrophysiological results suggest that the chitosan-graphene oxide scaffold could significantly restore the neurological function of rats. Moreover, the functional recovery of rats treated with chitosan-graphene oxide scaffold was better than that treated with chitosan scaffold. The results show that graphene oxide could have a positive role in the recovery of neurological function after spinal cord injury by promoting the degradation of the scaffold, adhesion, and migration of nerve cells to the scaffold. This study was approved by the Ethics Committee of Animal Research at the First Affiliated Hospital of Third Military Medical University (Army Medical University) (approval No. AMUWEC20191327) on August 30, 2019.

19.
Adv Mater ; 33(6): e2001105, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32893409

RESUMO

Nanocomposites, multiphase solid materials with at least one nanoscaled component, have been attracting ever-increasing attention because of their unique properties. Graphene is an ideal filler for high-performance multifunctional nanocomposites in light of its superior mechanical, electrical, thermal, and optical properties. However, the 2D nature of graphene usually gives rise to highly anisotropic features, which brings new opportunities to tailor nanocomposites by making full use of its excellent in-plane properties. Here, recent progress on graphene/polymer nanocomposites is summarized with emphasis on strengthening/toughening, electrical conduction, thermal transportation, and photothermal energy conversion. The influence of the graphene configuration, including layer number, defects, and lateral size, on its intrinsic properties and the properties of graphene/polymer nanocomposites is systematically analyzed. Meanwhile, the role of the interfacial interaction between graphene and polymer in affecting the properties of nanocomposites is also explored. The correlation between the graphene distribution in the matrix and the properties of the nanocomposite is discussed in detail. The key challenges and possible solutions are also addressed. This review may provide a constructive guidance for preparing high-performance graphene/polymer nanocomposite in the future.

20.
ACS Appl Bio Mater ; 4(1): 267-276, 2021 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-35014283

RESUMO

The development of cardiac models that faithfully recapitulate heart conditions is the goal of cardiac biomedical research. Among the numerous limitations of current models, replication of the cardiac microenvironment is one of the key challenges, and the effect of mechanical cues remains obscure in cardiac tissue. In this paper, different topological structures in the engineered cardiac models are summarized, and mechanical regulation of myocyte morphology and functional responses are discussed. Microenvironmental cues in vivo are influencing cardiac functions from cellular to tissue levels, and replications of these micro and macro features in the in vitro cardiac model shed light on cardiac research from a mechanistic point of view. With simple manipulation of topology, both physiological and pathological cardiac constructs can be remodeled to investigate the origin of abnormal cell phenotypes and functional responses in cardiac diseases. The integration of topological guidance with heart-on-a-chip devices is covered briefly and limitations of the current cardiac constructs are also addressed for future advancements in personalized medicine.


Assuntos
Modelos Biológicos , Miócitos Cardíacos/fisiologia , Cardiomiopatias/patologia , Técnicas de Cultura de Células em Três Dimensões , Matriz Extracelular/metabolismo , Humanos , Dispositivos Lab-On-A-Chip , Mecanotransdução Celular , Contração Miocárdica/fisiologia , Miócitos Cardíacos/citologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...