Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Cardiology ; : 1-11, 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38885621

RESUMO

INTRODUCTION: Cardiovascular disease nursing is a critical clinical application that necessitates real-time monitoring models. Previous models required the use of multi-lead signals and could not be customized as needed. Traditional methods relied on manually designed supervised algorithms, based on empirical experience, to identify waveform abnormalities and classify diseases, and were incapable of monitoring and alerting abnormalities in individual waveforms. METHODS: This research reconstructed the vector model for arbitrary leads using the phase space-time-delay method, enabling the model to arbitrarily combine signals as needed while possessing adaptive denoising capabilities. After employing automatically constructed machine learning algorithms and designing for rapid convergence, the model can identify abnormalities in individual waveforms and classify diseases, as well as detect and alert on abnormal waveforms. RESULT: Effective noise elimination was achieved, obtaining a higher degree of loss function fitting. After utilizing the algorithm in Section 3.1 to remove noise, the signal-to-noise ratio increased by 8.6%. A clipping algorithm was employed to identify waveforms significantly affected by external factors. Subsequently, a network model established by a generative algorithm was utilized. The accuracy for healthy patients reached 99.2%, while the accuracy for APB was 100%, for LBBB 99.32%, for RBBB 99.1%, and for P-wave peak 98.1%. CONCLUSION: By utilizing a three-dimensional model, detailed variations in electrocardiogram signals associated with different diseases can be observed. The clipping algorithm is effective in identifying perturbed and damaged waveforms. Automated neural networks can classify diseases and patient identities to facilitate precision nursing.

2.
Cureus ; 16(2): e53620, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38449953

RESUMO

Introduction To predict postoperative myocardial infarction rates in patients who undergo noncardiac surgery, the Canadian Cardiovascular Society Guidelines on Perioperative Cardiac Risk Assessment and Management recommends assessment of brain natriuretic peptide (BNP) in certain patients. Serial troponins are measured if the BNP level is elevated. In certain cases, Revised Cardiac Risk Index (RCRI) alone does not perform well, for example, during vascular surgery. Cardiac events occur in 20% of all vascular surgery patients. The odds ratio for such events is 9.2 if ST segments were depressed by 1 mm intraoperatively (relative to the PR interval) within the first 48 hours postoperatively. Increasing the number of cables and pads from three to five for electrocardiogram (EKG) increases the sensitivity from around 30% to over 80% for ischemic events relative to a formal EKG stress test, and then the monitor continuously displays not only lead II but also lead V5. Methods Our hypothesis was that raising awareness about diagnostic and therapeutic options to reduce the risk of postoperative myocardial infarction would increase the use of five pads. We conducted open-ended surveys at six hospitals to assess the reasons for choosing three pads. In our university hospital practice, we measured a cross-sectional incidence of using three pads before and, once again, a month after an intervention during a single morning. Several resident conferences encouraged the use of five pads. Education included weekly lectures and informal discussions with other staff during surgery, demonstrating that using five pads allows interrogation of an entire 12-lead EKG. In comparison, three pads only allow viewing three leads. Results At baseline, only three pads were available in 96% of our 23 operating rooms. Five cables were available in eight of those surgeries, but two were taped off to the side. Surveys unveiled scarcity of equipment and, more importantly, disempowerment (i.e., knowing how to diagnose or when to treat ischemia). After several conferences, the prevalence of equipment availability of only three pads fell to 47%. Conclusions Education enumerated details of recognizing ischemic configurations of ST depression. Next, education revealed methods to interrupt the progression of ischemia to infarction such as elevated blood pressure and hematocrit, reducing heart rate, and calling a cardiology consultant if the anesthesiologist wishes to draw serial troponins. Barriers to implementing an enhanced recovery after surgery (ERAS) pathway began with a need for more access to manage stress tests or optimize blood pressure medications after a preoperative anesthesia evaluation. The intraoperative barrier was knowing what to do if ST depression occurs. Therefore, we began raising awareness by encouraging the addition of an element of a future ERAS pathway, adding a cost of only $1 to monitor lead V5. Future ERAS pathways can include preoperative stress tests and consults, as found in published guidelines.

3.
Technol Health Care ; 32(1): 411-421, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37694323

RESUMO

BACKGROUND: Chinese chest pain centers (CPCs) have been expanding and maturing for the past decade, but patient wait times for pre-hospital care remain long. OBJECTIVE: To demonstrate that the remote electrocardiogram (ECG) monitoring system can ensure more efficient treatment for patients with ST-elevation myocardial infarction (STEMI) in CPCs, we compared patients with high-risk chest pain who used remote ECG monitoring systems to those who used conventional ECGs in retrospective cohort study. METHODS: Based on the inclusion and exclusion criteria, 290 patients who visited our CPC between June 2019 and March 2022 with acute chest pain and a diagnosis of STEMI as well as patients who had undergone an emergency primary percutaneous coronary intervention were selected. Among them, 73 patients with STEMI had employed remote real-time dynamic 12-lead ECG monitoring devices, while 217 patients with STEMI (i.e., the controls) had used conventional ECG monitoring. The effectiveness of treatment procedures for the two groups was investigated. As statistical measures, the symptom onset-to-wire times, first medical contact (FMC)-to-wire times, door-to-wire times, major adverse cardiac events in hospital, and the troponin T levels were analyzed. RESULTS: Compared with the control group, the patients with remote real-time dynamic 12-lead ECG monitoring devices showed shorter times for both symptom onset-to-wire (234.8 ± 95.8 min vs. 317.6 ± 129.6 min, P= 0.0321) and from symptom onset-to-FMC (170.5 ± 86.3 min vs. 245.3 ± 115.6 min, P= 0.0287); this group also had a lower 30-day mortality rate (2.73% vs. 4.14%, P= 0.003). The differences between the two groups were statistically significant (P< 0.05). CONCLUSION: With remote real-time dynamic 12-lead ECG monitoring equipment, myocardial ischemia can be treated more quickly, leading to fewer possible cardiac events and a better prognosis.


Assuntos
Serviços Médicos de Emergência , Infarto do Miocárdio , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/terapia , Estudos Retrospectivos , Clínicas de Dor , Dor no Peito/diagnóstico , Dor no Peito/etiologia , Eletrocardiografia/métodos
4.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 40(6): 1084-1092, 2023 Dec 25.
Artigo em Chinês | MEDLINE | ID: mdl-38151930

RESUMO

Electrocardiogram (ECG) monitoring owns important clinical value in diagnosis, prevention and rehabilitation of cardiovascular disease (CVD). With the rapid development of Internet of Things (IoT), big data, cloud computing, artificial intelligence (AI) and other advanced technologies, wearable ECG is playing an increasingly important role. With the aging process of the population, it is more and more urgent to upgrade the diagnostic mode of CVD. Using AI technology to assist the clinical analysis of long-term ECGs, and thus to improve the ability of early detection and prediction of CVD has become an important direction. Intelligent wearable ECG monitoring needs the collaboration between edge and cloud computing. Meanwhile, the clarity of medical scene is conducive for the precise implementation of wearable ECG monitoring. This paper first summarized the progress of AI-related ECG studies and the current technical orientation. Then three cases were depicted to illustrate how the AI in wearable ECG cooperate with the clinic. Finally, we demonstrated the two core issues-the reliability and worth of AI-related ECG technology and prospected the future opportunities and challenges.


Assuntos
Doenças Cardiovasculares , Dispositivos Eletrônicos Vestíveis , Humanos , Inteligência Artificial , Reprodutibilidade dos Testes , Eletrocardiografia
5.
Polymers (Basel) ; 15(18)2023 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-37765706

RESUMO

Skin has a dynamic surface and offers essential information through biological signals originating from internal organs, blood vessels, and muscles. Soft and stretchable bioelectronics can be used in wearable machines for long-term stability and to continuously obtain distinct bio-signals in conjunction with repeated expansion and contraction with physical activities. While monitoring bio-signals, the electrode and skin must be firmly attached for high signal quality. Furthermore, the signal-to-noise ratio (SNR) should be high enough, and accordingly, the ionic conductivity of an adhesive hydrogel needs to be improved. Here, we used a chitosan-alginate-chitosan (CAC) triple hydrogel layer as an interface between the electrodes and the skin to enhance ionic conductivity and skin adhesiveness and to minimize the mechanical mismatch. For development, thermoplastic elastomer Styrene-Ethylene-Butylene-Styrene (SEBS) dissolved in toluene was used as a substrate, and gold nanomembranes were thermally evaporated on SEBS. Subsequently, CAC triple layers were drop-casted onto the gold surface one by one and dried successively. Lastly, to demonstrate the performance of our electrodes, a human electrocardiogram signal was monitored. The electrodes coupled with our CAC triple hydrogel layer showed high SNR with clear PQRST peaks.

6.
Pacing Clin Electrophysiol ; 46(3): 205-216, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36788130

RESUMO

BACKGROUND: Left bundle branch area pacing (LBBaP) as an alternative method for delivering physiological pacing, is difficult for many primary hospitals that lack the electrophysiological multichannel recorder to carry out. We hope to find a simple and feasible method that combines the multi-lead surface electrocardiogram (ECG) monitoring and the intracavity ECG of the pacing programmer to achieve LBBaP. METHODS: A total of 50 patients with bradycardia indications who attempted permanent pacemaker implantation were included in this study. We referred to multi-lead surface ECG monitoring and pacing system analyzer (PSA), combined with the nine-zone pacing method of the LBBaP, to complete LBBaP. We assessed multiple parameters to verify whether the LBBaP was successfully achieved and used univariable analysis of variance for repeated measures to judge the feasibility and effectiveness of LBBaP without the electrophysiological multichannel recorder. RESULTS: LBBaP was successfully archived without the electrophysiological multichannel recorder in 44 of 50 patients (88%). In the study, paced QRS duration and the stimulus to peak left ventricular activation time (Sti-LVAT) were 117.04 ± 10.34 ms and 71.10 ± 7.91 ms and had no significant changes in the 3-month follow-up. The unipolar pacing threshold and R-wave amplitudes were 0.85 ± 0.32 V and 10.36 ± 5.24 mV at baseline respectively, which also showed stability during the 1-month and 3-month follow-up. During the 3-month follow-up, no lead-related complication was recorded. CONCLUSION: It is effective and feasible to achieve LBBaP combining the multi-lead ECG monitoring and the intracavitary ECG of PSA without the electrophysiological multichannel recorder, which could be an alternative to perform LBBaP.


Assuntos
Fascículo Atrioventricular , Estimulação Cardíaca Artificial , Humanos , Estimulação Cardíaca Artificial/métodos , Estudos de Viabilidade , Sistema de Condução Cardíaco , Eletrocardiografia/métodos , Resultado do Tratamento
7.
Journal of Biomedical Engineering ; (6): 1084-1092, 2023.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1008937

RESUMO

Electrocardiogram (ECG) monitoring owns important clinical value in diagnosis, prevention and rehabilitation of cardiovascular disease (CVD). With the rapid development of Internet of Things (IoT), big data, cloud computing, artificial intelligence (AI) and other advanced technologies, wearable ECG is playing an increasingly important role. With the aging process of the population, it is more and more urgent to upgrade the diagnostic mode of CVD. Using AI technology to assist the clinical analysis of long-term ECGs, and thus to improve the ability of early detection and prediction of CVD has become an important direction. Intelligent wearable ECG monitoring needs the collaboration between edge and cloud computing. Meanwhile, the clarity of medical scene is conducive for the precise implementation of wearable ECG monitoring. This paper first summarized the progress of AI-related ECG studies and the current technical orientation. Then three cases were depicted to illustrate how the AI in wearable ECG cooperate with the clinic. Finally, we demonstrated the two core issues-the reliability and worth of AI-related ECG technology and prospected the future opportunities and challenges.


Assuntos
Humanos , Inteligência Artificial , Reprodutibilidade dos Testes , Eletrocardiografia , Doenças Cardiovasculares , Dispositivos Eletrônicos Vestíveis
8.
Ter Arkh ; 94(9): 1062-1066, 2022 Oct 24.
Artigo em Russo | MEDLINE | ID: mdl-36286756

RESUMO

AIM: To evaluate the effectiveness of a new system for telemetric electrocardiogram (ECG) monitoring in patients after endovascular interventions (EI) on the coronary arteries (CA). MATERIALS AND METHODS: 168 patients with chronic ischemic heart disease who underwent EI on the CA on an outpatient basis, and during routine hospitalization, followed by telemetric ECG-monitoring after interventions were included. The monitoring was carried out using a three-channel telemetric recorder Astrocard HE3 (Russia), which provides continuous monitoring of 3-lead ECG for a long time. RESULTS: The telemetry was successfully performed in all 168 (100%) patients. In 165 (98%) patients, the quality of the recording was regarded as good, in 3 (2%) as satisfactory. There were no cases of disconnection of the device, no interruptions in recording. During the observation period, no life-threatening arrhythmia revealed. When comparing the telemetry results in different groups of patients, there were no significant differences in the incidence of arrhythmia. Patients with a history of percutaneous coronary interventions were questioned; according to which 92% of respondents reported that they felt more comfortable after the intervention followed by telemetric ECG-monitoring. CONCLUSION: Carrying out telemetric ECG-monitoring after EI on the CA improves the quality of observation after the procedure, promotes early discharge of patients, makes the intervention more comfortable and safe. The introduction of this technique into clinical practice will make it possible to more widely use the outpatient approach when carrying out EI, and to increase the turnover of specialized beds and the efficiency of the work of medical institutions.


Assuntos
Vasos Coronários , Eletrocardiografia , Humanos , Vasos Coronários/diagnóstico por imagem , Eletrocardiografia/métodos , Telemetria/métodos , Arritmias Cardíacas , Federação Russa
9.
Biosens Bioelectron ; 205: 114072, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35192998

RESUMO

Blood pressure (BP) is a cardiovascular parameter which exhibits significant variability. Whilst continuous BP monitoring would be of significant clinical utility. This is particularly challenging outside the hospital environment. New wearable cuff-based and cuffless BP monitoring technologies provide some capacity, however they have a number of limitations including bulkiness, rigidity and discomfort, poor accuracy and motion artefact. Here, we report on a lightweight, user-friendly, non-invasive wearable cardiac sensing system based on deformation-insensitive conductive gold nanowire foam (G-foam) and pressure-sensitive resistive gold nanowire electronic skin (G-skin). The G-foam could serve as a new soft dry bioelectrode for electrocardiogram (ECG) monitoring; a new soft button-based G-skin design could avoid manual holding for continuous pulse recording. They could be integrated seamlessly with everyday bandage for facile wireless recording of ECG and artery pulses under real-word dynamic environments including walking, running, deep squatting, and jogging. Further machine learning algorithm was developed for estimation of systolic and diastolic BP, showing comparable accuracy to commercial cuff-based sphygmomanometer. The measured dynamic BP changes correlated well with the volunteer's daily activities, indicating the potential applications of our soft wearable systems for real-time diagnostics of cardiovascular functions in complex dynamic real-world setting.


Assuntos
Técnicas Biossensoriais , Nanofios , Dispositivos Eletrônicos Vestíveis , Determinação da Pressão Arterial , Ouro , Humanos
10.
Br J Cardiol ; 28(1): 13, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35747482

RESUMO

The incremental shuttle walk test (ISWT) is a valid, reliable submaximal exercise test used in the assessment of patients prior to cardiac rehabilitation (CR). Simultaneous electrocardiogram (ECG) measurements would provide important information on the safety of the test, and adequacy of subsequent cardiac risk stratification. Risk stratification is recommended to assess patients' suitability for cardiac rehabilitation. For example, ST-segment depression >2 mm from baseline during testing would place a person in a high-risk category. However, such ECG measurements are rarely undertaken in clinical practice. The aim of the study was to investigate the incidence of ECG changes during an ISWT, and report on the possible impact of these findings on subsequent cardiac risk stratification. A retrospective case note review was undertaken for the year 2017. Baseline clinical characteristics from eligible patients were gathered including those with ischaemic heart disease, heart failure, transplant and valve replacement, along with ECG measurements during the ISWT. The impact of ECG findings on cardiac risk stratification was calculated, based on risk stratification developed by the American Association of Cardiovascular and Pulmonary Rehabilitation. The safety of the ISWT was measured by the absence of major ECG changes. Data were gathered for 295 patients. Minor ECG changes were identified during the ISWT in 189 patients (64.1%), with no major changes. The presence of silent myocardial ischaemia (ST-segment depression) had an impact on cardiac risk stratification in 27 patients. There was a statistically significant positive association between ST-segment depression with cardiac risk stratification (p<0.001). In conclusion, the ISWT is safe in terms of ECG changes. The impact of ECG findings on cardiac risk stratification is significant and worthy of further consideration.

11.
Int J Stroke ; 16(7): 809-817, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33232196

RESUMO

BACKGROUND: Timely identification of occult atrial fibrillation following cryptogenic stroke facilitates consideration of oral anticoagulation therapy. Extended electrocardiography monitoring beyond 24 to 48 h Holter monitoring improves atrial fibrillation detection rates, yet uncertainty remains due to upfront costs and the projected long-term benefit. We sought to determine the cost-effectiveness of three electrocardiography monitoring strategies in detecting atrial fibrillation after cryptogenic stroke. METHODS: A decision-analytic Markov model was used to project the costs and outcomes of three different electrocardiography monitoring strategies (i.e. 30-day electrocardiography monitoring, three-year implantable loop recorder monitoring, and conventional Holter monitoring) in acute stroke survivors without previously documented atrial fibrillation. RESULTS: The lifetime discounted costs and quality-adjusted life years were $206,385 and 7.77 quality-adjusted life years for conventional monitoring, $207,080 and 7.79 quality-adjusted life years for 30-day extended electrocardiography monitoring, and $210,728 and 7.88 quality-adjusted life years for the implantable loop recorder strategy. Additional quality-adjusted life years could be attained at a more favorable incremental cost per quality-adjusted life year with the implantable loop recorder strategy, compared with the 30-day electrocardiography monitoring strategy, thereby eliminating the 30-day strategy by extended dominance. The implantable loop recorder strategy was associated with an incremental cost per quality-adjusted life year gained of $40,796 compared with conventional monitoring. One-way sensitivity analyses indicated that the model was most sensitive to the rate of recurrent ischemic stroke. CONCLUSIONS: An implantable loop recorder strategy for detection of occult atrial fibrillation in patients with cryptogenic stroke is more economically attractive than 30-day electrocardiography monitoring compared to conventional monitoring and is associated with a cost per quality-adjusted life year gained in the range of other publicly funded therapies. The value proposition is improved when considering patients at the highest risk of recurrent ischemic stroke. However, the implantable loop recorder strategy is associated with increased health care costs, and the opportunity cost of wide scale implementation must be considered.


Assuntos
Fibrilação Atrial , AVC Isquêmico , Acidente Vascular Cerebral , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Análise Custo-Benefício , Eletrocardiografia , Eletrocardiografia Ambulatorial , Humanos , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/diagnóstico
12.
Arch Cardiovasc Dis ; 114(2): 122-131, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33153949

RESUMO

BACKGROUND: Premature atrial complexes from pulmonary veins are the main triggers for atrial fibrillation in the early stages. Thus, pulmonary vein isolation is the cornerstone of catheter ablation for paroxysmal atrial fibrillation. However, the success rate remains perfectible. AIM: To assess whether premature atrial complex characteristics before catheter ablation can predict pulmonary vein isolation success in paroxysmal atrial fibrillation. METHODS: We investigated consecutive patients who underwent catheter ablation for paroxysmal atrial fibrillation from January 2013 to April 2017 in two French centres. Patients were included if they were treated with pulmonary vein isolation alone, and had 24-hour Holter electrocardiogram data before catheter ablation available and a follow-up of≥6 months. Catheter ablation success was defined as freedom from any sustained atrial arrhythmia recurrence after a 3-month blanking period following catheter ablation. RESULTS: One hundred and three patients were included; all had an acute successful pulmonary vein isolation procedure, and 34 (33%) had atrial arrhythmia recurrences during a mean follow-up of 30±15 months (group 1). Patients in group 1 presented a longer history of atrial fibrillation (71.9±65.8 vs. 42.9±48.4 months; P=0.008) compared with those who were "free from arrhythmia" (group 2). Importantly, the daily number of premature atrial complexes before catheter ablation was significantly lower in group 1 (498±1413 vs. 1493±3366 in group 2; P=0.028). A daily premature atrial complex cut-off number of<670 predicted recurrences after pulmonary vein isolation (41.1% vs. 13.3%; sensitivity 88.2%; specificity 37.7%; area under the curve 0.635; P=0.017), and was the only independent predictive criterion in the multivariable analysis (4-fold increased risk). CONCLUSION: Preprocedural premature atrial complex analysis on 24-hour Holter electrocardiogram in paroxysmal atrial fibrillation may improve patient selection for pulmonary vein isolation.


Assuntos
Fibrilação Atrial/cirurgia , Complexos Atriais Prematuros/diagnóstico , Ablação por Cateter , Eletrocardiografia Ambulatorial , Frequência Cardíaca , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Complexos Atriais Prematuros/fisiopatologia , Ablação por Cateter/efeitos adversos , Tomada de Decisão Clínica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Paris , Valor Preditivo dos Testes , Veias Pulmonares/fisiopatologia , Recidiva , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
13.
J Stroke Cerebrovasc Dis ; 29(4): 104669, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32057653

RESUMO

BACKGROUND AND AIM: Rapid and sensitive detection of atrial fibrillation (AF) is of paramount importance for initiation of adequate preventive therapy after stroke. Stroke Unit care includes continuous electrocardiogram monitoring (CEM) but the optimal exploitation of the recorded ECG traces is controversial. In this retrospective single-center study, we investigated whether an automated analysis of continuous electrocardiogram monitoring (ACEM), based on a software algorithm, accelerates the detection of AF in patients admitted to our Stroke Unit compared to the routine CEM. METHODS: Patients with acute ischemic stroke or transient ischemic attack were consecutively enrolled. After a 12-channel ECG on admission, all patients received CEM. Additionally, in the second phase of the study the CEM traces of the patients underwent ACEM analysis using a software algorithm for AF detection. Patients with history of AF or with AF on the admission ECG were excluded. RESULTS: The CEM (n = 208) and ACEM cohorts (n= 114) did not differ significantly regarding risk factors, duration of monitoring and length of admission. We found a higher rate of newly-detected AF in the ACEM cohort compared to the CEM cohort (15.8% versus 10.1%, P < .001). Median time to first detection of AF was shorter in the ACEM compared to the CEM cohort [10 hours (IQR 0-23) versus 46.50 hours (IQR 0-108.25), P < .001]. CONCLUSIONS: ACEM accelerates the detection of AF in patients with stroke compared with the routine CEM. Further evidences are required to confirm the increased rate of AF detected using ACEM.


Assuntos
Fibrilação Atrial/diagnóstico , Isquemia Encefálica/etiologia , Eletrocardiografia , Unidades Hospitalares , Ataque Isquêmico Transitório/etiologia , Monitorização Fisiológica/métodos , Acidente Vascular Cerebral/etiologia , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/complicações , Fibrilação Atrial/fisiopatologia , Automação , Isquemia Encefálica/diagnóstico , Isquemia Encefálica/fisiopatologia , Diagnóstico Precoce , Feminino , Humanos , Ataque Isquêmico Transitório/diagnóstico , Ataque Isquêmico Transitório/fisiopatologia , Londres , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Processamento de Sinais Assistido por Computador , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/fisiopatologia
14.
J Clin Pharmacol ; 60(3): 284-294, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31743455

RESUMO

This is an article in the Journal of Clinical Pharmacology's Core Entrustable Professional Activities in Clinical Pharmacology series that discusses drug-induced proarrhythmia and is offered as a teaching aid for medical students and residents. Drugs from diverse pharmacological classes can lead to multiple types of arrhythmias including the polymorphic ventricular tachycardia torsades de pointes (TdP). Although typically occurring in self-limiting bursts with or without associated symptoms, which can range from mild lightheadedness and palpitations to syncope and seizures, TdP can also occasionally progress to ventricular fibrillation and sudden cardiac death. To provide patients with the optimal therapeutic benefits of potentially proarrhythmic drugs, prescribers are responsible for obtaining a good understanding of the compound's benefit-risk properties and perform a judicious assessment of the patient's clinical characteristics and individual risk factors. Dose adjustments and/or additional monitoring of electrocardiograms and electrolyte balances may be appropriate in some cases. This article explains the pharmacological mechanism of action of drug-induced proarrhythmia associated with compounds that prolong the repolarization period, illustrates how this liability is conveyed in a drug's prescribing information (label), details the clinical characteristics of patients most susceptible to this type of proarrhythmia, and describes interventions that can be made if TdP occurs. Three clinical vignettes are provided at the end of the article to highlight the relevance of the preceding discussions.


Assuntos
Arritmias Cardíacas/induzido quimicamente , Prescrições de Medicamentos , Arritmias Cardíacas/terapia , Rotulagem de Medicamentos , Monitoramento de Medicamentos , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos/epidemiologia , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos/terapia , Educação Médica , Eletrocardiografia , Humanos , Síndrome do QT Longo/induzido quimicamente , Síndrome do QT Longo/terapia , Educação de Pacientes como Assunto , Medição de Risco , Torsades de Pointes/induzido quimicamente , Torsades de Pointes/terapia
15.
Acta Obstet Gynecol Scand ; 99(3): 413-422, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31792930

RESUMO

INTRODUCTION: Noninvasive fetal heart rate monitoring using transabdominal fetal electrocardiographic detection is now commercially available and has been demonstrated to be an effective alternative to traditional Doppler ultrasonographic techniques. Our objective in this study was to compare the results of computerized identification of fetal heart rate patterns generated by ultrasound-based and transabdominal fetal electrocardiogram-based techniques with simultaneously obtained fetal scalp electrode-derived heart rate information. MATERIAL AND METHODS: We applied an objective computer-based analysis for recognition of fetal heart rate patterns (Monica Decision Support) to data obtained simultaneously from a direct fetal scalp electrode, Doppler ultrasound, and the abdominal-fetal electrocardiogram techniques. This allowed us to compare over 145 hours of fetal heart rate patterns generated by the external devices with those derived from the scalp electrode in 30 term singleton uncomplicated pregnancies during labor. The direct fetal scalp electrode is considered to be the most accurate and reliable technique used in current clinical practice, and was, therefore, used as the standard for comparison. The program quantified the baseline heart rate, long- and short-term variability. It indicated when an acceleration or deceleration was present and whether it was large or small. RESULTS: Ultrasound was associated with significantly greater deviations from the fetal scalp electrode results than the abdominal fetal electrocardiogram technique in recognizing the correct baseline heart rate, its variability, and the presence of small and large accelerations and small decelerations. For large decelerations the two external methods were each not significantly different from the scalp electrode results. CONCLUSIONS: Noninvasive fetal heart rate monitoring using maternal abdominal wall electrodes to detect fetal cardiac activity more reliably reproduced the computerized analysis of heart rate patterns derived from a direct fetal scalp electrode than did traditional ultrasound-based monitoring. Abdominal-fetal electrocardiogram should, therefore, be considered a primary option for externally monitored patients.


Assuntos
Eletrocardiografia , Monitorização Fetal/normas , Frequência Cardíaca Fetal , Primeira Fase do Trabalho de Parto , Trabalho de Parto , Ultrassonografia Pré-Natal , Adulto , Feminino , Monitorização Fetal/instrumentação , Humanos , Processamento de Imagem Assistida por Computador , Gravidez , Ultrassonografia Doppler
16.
Sensors (Basel) ; 19(20)2019 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-31615163

RESUMO

Body surface potential mapping (BSPM) is a valuable tool for research regarding electrocardiograms (ECG). However, the BSPM system is limited by its large number of electrodes and wires, long installation time, and high computational complexity. In this paper, we designed a wearable four-electrode electrocardiogram-sensor (WFEES) module that measures six-channel ECGs simultaneously for ECG investigation. To reduce the testing lead number and the measurement complexity, we further proposed a method, the layered (A, N) square-based (LANS) method, to optimize the ECG acquisition and analysis process using WFEES modules for different applications. Moreover, we presented a case study of electrode location optimization for wearable single-lead ECG monitoring devices using WFEES modules with the LANS method. In this study, 102 sets of single-lead ECG data from 19 healthy subjects were analyzed. The signal-to-noise ratio of ECG, as well as the mean and coefficient of variation of QRS amplitude, was derived among different channels to determine the optimal electrode locations. The results showed that a single-lead electrode pair should be placed on the left chest above the electrode location of standard precordial leads V1 to V4. Additionally, the best orientation was the principal diagonal as the direction of the heart's electrical axis.


Assuntos
Algoritmos , Eletrocardiografia , Dispositivos Eletrônicos Vestíveis , Adulto , Mapeamento Potencial de Superfície Corporal , Eletrodos , Feminino , Humanos , Masculino , Processamento de Sinais Assistido por Computador , Razão Sinal-Ruído
17.
BMJ Open ; 9(3): e023923, 2019 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-30842109

RESUMO

INTRODUCTION: Patients with chronic heart failure (CHF) can benefit from exercise rehabilitation (ER) with significant improvements in exercise capacity, quality of life and reduction in hospitalisations. Despite its reported benefits, only a small number of patients with CHF attend ER due to poor adherence, and improper exercise may even lead to adverse events. Remote ECG monitoring system (REMS) has the potential to overcome these obstacles. We hypothesise that home-based cardiac ER using REMS in CHF patients is effective compared with conventional ER without monitoring. METHODS AND ANALYSIS: This study is a prospective, randomised, parallel controlled clinical trial designed to evaluate the effectiveness of home-based phase-II ER with REMS in the treatment of CHF with a target enrolment of 120 patients (left ventricular ejection fraction <50%, New York Heart Association (NYHA) classes I to III). Patients are randomised to either REMS rehabilitation group or conventional rehabilitation group in a 1:1 ratio. All patients start an exercise training in a supervised setting and then transition to a home-based regimen. The supervised training phase consists of 12 supervised training sessions, three sessions per week for 4 weeks. During the home exercise phase, patients exercise five times per week for 8 weeks. In the REMS group, patients wear monitors during exercise to ensure that exercise intensity is within the set ranges. REMS will also detect risky arrhythmia and alert the patients and their doctors on time. The training intensity is not monitored in the conventional rehabilitation group. The primary outcome is exercise capacity improvement measured by peak oxygen uptake (VO2 peak) (baseline vs 3 m). Secondary outcomes include 6-min walk test, NYHA classes, echocardiographic parameters, cardiac biomarkers, major adverse cardiovascular events, quality of life, psychological well-being and patients' adherence to the rehabilitation programme. ETHICS AND DISSEMINATION: This study was approved by Ethics Committee of China-Japan Friendship Hospital for Clinical Research (No. 2018-55 K39). The results of this study will be disseminated via peer-reviewed publications and presentations at conferences. TRIAL REGISTRATION NUMBER: ChiCTR-RNR-17012446; Pre-results.


Assuntos
Reabilitação Cardíaca , Terapia por Exercício/métodos , Insuficiência Cardíaca/reabilitação , Qualidade de Vida , Autocuidado , China , Doença Crônica , Eletrocardiografia , Humanos , Monitorização Fisiológica/métodos , Cooperação do Paciente , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto , Volume Sistólico , Função Ventricular Esquerda , Teste de Caminhada
18.
Rev Esp Cardiol (Engl Ed) ; 72(6): 473-478, 2019 Jun.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-29805092

RESUMO

INTRODUCTION AND OBJECTIVES: To assess the diagnostic yield and cost-effectiveness of a diagnostic protocol based on the systematic use of latest-generation external loop recorders (ELRs) compared with the classic diagnostic strategy for patients with recurrent unexplained palpitations. METHODS: Two cohorts of consecutive patients referred for diagnosis of unexplained palpitations to the outpatient clinic of the arrhythmia unit were compared: a prospective cohort after the implementation of a new diagnostic protocol based on the systematic use of ELRs, and another, retrospective, cohort before the implementation of the protocol. The cost of diagnosis was calculated based on the number of complementary examinations, visits to outpatient clinics, or emergency department visits required to reach a diagnosis, and its costs according the prices published for the local health system. RESULTS: One hundred and forty-nine patients were included (91 in the ELR group, 58 in the control group). The diagnostic yield was higher in the ELR group (79 [86.8%] definitive diagnoses in the ELR group vs 12 [20.7%] in the control group, P < .001). The cost per diagnosis was €375.13 in the ELR group and €5184.75 in the control group (P < .001). The cost-effectiveness study revealed that the systematic use of ELR resulted in a cost reduction of €11.30 for each percentage point of increase in diagnosis yield. CONCLUSIONS: In patients with recurrent unexplained palpitations, evaluation by means of a study protocol that considers the systematic use of a latest-generation ELR increases diagnostic yield while reducing the cost per diagnosis.


Assuntos
Arritmias Cardíacas/diagnóstico , Eletrocardiografia Ambulatorial/instrumentação , Frequência Cardíaca/fisiologia , Arritmias Cardíacas/economia , Arritmias Cardíacas/fisiopatologia , Análise Custo-Benefício , Eletrocardiografia Ambulatorial/economia , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes
19.
Int J Biometeorol ; 63(1): 93-105, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30565078

RESUMO

The effect of local atmosphere status and space weather on the healthy volunteers and the patients suffering arterial hypertension (AH) is studied. The research group included 12 healthy volunteers and 15 patients suffering AH of 1-2 degree. In the period of 24-h electrocardiogram monitoring (ECG), all the patients suffering AH continued to take effective antihypertensive therapy individually prescribed. All the patients and volunteers had normal sinus rhythm without disorders in cardiac conduction pathways. The ECG monitoring covered the period from November 23, 2016 till March 29, 2017. During this period, 4 moderate and 11 minor magnetic storms occurred. The horizontal component of the magnetic field recorded ranged from 140 to 270 nT. We used multi-classifier algorithm based on the decision tree with parallel branching, which specially developed by the authors. Apart from the horizontal component of magnetic field, 6 basic characteristics of the local weather data were used as the predictors of the algorithm. The output of this algorithm is elementary statement of cause-consequence connection (insight). In the periods of weak frost and intense precipitations (snow or rain with snow), the combination of rather high horizontal component of the magnetic field with elevated atmospheric pressure and humidity resulted in abnormal RR, PR, and QT intervals of ECG.


Assuntos
Eletrocardiografia , Campos Magnéticos , Tempo (Meteorologia) , Adulto , Idoso , Algoritmos , Meio Ambiente Extraterreno , Feminino , Voluntários Saudáveis , Humanos , Hipertensão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica
20.
Chinese Critical Care Medicine ; (12): 355-358, 2019.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-753969

RESUMO

Objective To design a new modified sick clothes for electrocardiogram (ECG) monitoring, and to observe its clinical application effect. Methods In order to overcome the shortcomings of the existing modified ECG monitoring clothes, a new type of modified sick clothes was designed on the basis of the traditional sick clothes, and a national utility model patent was obtained. 408 conscious patients with ECG monitoring admitted to department of neurology of the First Affiliated Hospital of Fujian Medical University from January 2015 to June 2018 were enrolled, and they were randomly divided into three groups according to the order of admission for comparing the wearing effect of three kinds of sick clothes. 133 patients dressed traditional clothes, while 139 patients dressed modified ECG monitoring clothes. According to the method reported in the literature, the pockets were removed on the basis of the traditional patient clothes, and a circular hole 5 cm in diameter was made at the position of the electrodes for ECG monitoring, which was used to pass through the lead wire and the electrodes. 136 patients dressed the new modified sick clothes. In view of the inconvenience of ECG monitoring and stimulation of patients' thoracic and abdominal skin by traditional sick clothes, the existing modified ECG monitoring clothes were not easy to operate, the location of electrodes sticking was not easy to judge and the lead line was messy, the new modified sick clothes were still based on the traditional ones. The three circular holes of the existing modified ECG monitoring clothes were made into incisions about 12 cm in length to facilitate the ECG monitoring lead line and electrodes sticking. A compression band or a simple patch was added to each side near the shoulder for tidying up the fixed lead. The self-evaluation of patient's comfort, the operation time of ECG monitoring by nurses, skin allergy rate and lead damage rate were recorded and compared among the three groups. Results Compared with the traditional sick clothes and the modified ECG monitoring clothes groups, the patients in the new modified sick clothes group had higher comfort [the proportion of no discomfort: 11.0% (15/136) vs. 0% (0/133), 5.8% (8/139); the proportion of severe discomfort: 0% (0/136) vs. 4.5% (6/133), 0.7% (1/139), all P < 0.05], the installation and disassembly time of ECG monitoring by nurses was significantly shortened [installation time (s): 69.12±16.47 vs. 96.74±3.89, 88.24±9.83; disassembly time (s): 50.24±4.54 vs. 75.76±4.98, 66.54±7.86, all P < 0.01], and the skin allergies rate [3.7% (5/136) vs. 15.8% (21/133), 8.6% (12/139)] and the insulation loss rate of the lead wires [2.9% (4/136) vs. 15.8% (21/133), 7.9% (11/139)] were significantly lowered (all P < 0.05). Conclusion The ECG monitoring patients using new modified sick clothes could increase their comfort, reduce the workload of nurses, save medical consumables, and have beautiful appearance and high practicability, which was worthy of clinical application.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...