Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
1.
J Contemp Dent Pract ; 25(6): 575-580, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-39364824

RESUMO

AIM: The aim of this study is to compare the fracture resistance of canine teeth restored using TRINIA Endocrowns with three different types of preparations (2, 3, and 4 intracanal preparations). MATERIALS AND METHODS: Thirty maxillary-extracted canines were collected. All teeth were fixed in orthodontic acrylic resin and decapitated at the level of the proximal cemento-enamel junction (CEJ). After being endodontically treated, specimens were distributed equally between 3 groups (n = 10) with different preparation depths (GT: 2 mm Intraradicular Preparation, GH: 3 mm Intraradicular Preparation, GF: 4 mm Intraradicular Preparation). Thirty TRINIA endocrowns were dry milled. After surface treatment, all endocrowns were bonded to their corresponding roots using Permaflo a dual-cure resin cement. Each specimen was then fixed in the lower part of a universal testing machine with a load cell of 5 KN, at an angle of 45 degrees to the tooth long-axis at 0.5 mm/min crosshead speed. Failure loads were recorded in Newton's. Data were recorded, organized, and statistically investigated. RESULTS: Shapiro-Wilk tests revealed that the data were not normally distributed. Descriptive statistics revealed a high mean fracture resistance of GH (647 N), then GT (475.6 N), and finally GF (353.9 N). The Kruskal-Wallis test revealed a significant difference that existed between the groups being studied (p = 0.036). CONCLUSION: TRINIA endocrowns with intracanal preparations of 2 and 3 mm provide more promising fracture resistance than those with intracanal preparations of 4 mm as a way of treating of root-canal-treated maxillary canines. TRINIA endocrowns (2 and 3 mm intracanal preparations) are as promising as fiber posts and all ceramic crowns in terms of fracture resistance. TRINIA endocrowns with 2 mm intracanal preparations are mostly reparable after failure, but those of 3 and 4 mm are mostly irreparable after failure. CLINICAL SIGNIFICANCE: Modifying endocrowns to have intraradicular projections, simulating Nayyar core, may improve the success and longevity of endocrowns in anterior teeth. How to cite this article: Alahmad AM, Alenezi AY, Rayyan M, et al. Static Loading of Different Intraradicular Preparation Depths of Trinia Endocrowns in Maxillary Canines. J Contemp Dent Pract 2024;25(6):575-580.


Assuntos
Dente Canino , Análise do Estresse Dentário , Maxila , Humanos , Fraturas dos Dentes , Preparo de Canal Radicular/métodos , Preparo de Canal Radicular/instrumentação , Coroas
2.
Sci Rep ; 14(1): 17027, 2024 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-39043857

RESUMO

This study aims to compare the roughness between the central and edge points on the porcelain sectional surface of porcelain fused to Co-Cr alloy endocrowns. Utilizing anatomical data from average molar dimensions, a simplified model for the endocrowns was created. Eight porcelain fused to Co-Cr alloy endocrowns were fabricated with an edge thickness of 0.3 mm. Following casting, firing, cutting, and polishing procedures, the roughness on porcelain sectional surface at both the central and edge points of the inner crown was assessed using an atomic force microscope (AFM). The roughness measurement (Sq value) for the central point on porcelain sectional surface was (10.46 ± 3.37 nm), and for the edge point, it was (10.50 ± 1.99 nm). There was no statistically significant distinction between the central and edge points in terms of roughness. Despite the uneven thickness of the inner crown in porcelain fused to Co-Cr alloy endocrowns, it was observed that this disparity had negligible impact on the internal microstructure of the porcelain. Therefore, its application in dental clinical settings could be deemed viable.

3.
Clin Exp Dent Res ; 10(3): e901, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38770577

RESUMO

OBJECTIVES: The study aimed to evaluate the debonding resistance of three different endocrown designs on molar teeth, using three different zirconia surface pretreatments. MATERIAL AND METHOD: Ninety human mandibular first molars were divided into three main groups: endocrowns without ferrule, with 1 mm ferrule, and with 2 mm ferrule. The subgroups were defined by their surface pretreatment method used (n = 15): 50 µm alumina air-particle abrasion, silica coating using 30 µm Cojet™ particles, and Zircos-E® etching. The endocrowns were fabricated using multilayer zirconia ceramic, cemented with self-adhesive resin cement, and subjected to 5000 thermocycles (5-55°C) before debonding. The data obtained were analyzed using a two-way ANOVA. RESULTS: All test specimens survived the thermocyclic aging. The results indicated that both the preparation design and the surface treatment had a significant impact on the resistance to debonding of the endocrowns (p < .001). The 2 mm ferrule followed by the 1 mm ferrule designs exhibited the highest debonding resistance, both were superior to the endocrown without ferrule. Zircos-E® etching and silica coating yielded comparable debonding resistance, which were significantly higher than alumina air-particle abrasion. All endocrowns demonstrated a favorable failure mode. CONCLUSIONS: All designs and surface treatments showed high debonding resistance for a single restoration. However, ferrule designs with Zircos-E® etching or silica coating may represent better clinical options compared to the nonferrule design or alumina airborne-particle abrasion. Nonetheless, further research, including fatigue testing and evaluations with different luting agents is recommended.


Assuntos
Óxido de Alumínio , Dióxido de Silício , Propriedades de Superfície , Zircônio , Óxido de Alumínio/química , Humanos , Dióxido de Silício/química , Zircônio/química , Dente Molar , Teste de Materiais , Abrasão Dental por Ar/métodos , Cimentos de Resina/química , Corrosão Dentária/métodos , Análise do Estresse Dentário , Planejamento de Prótese Dentária
4.
Materials (Basel) ; 17(6)2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38541565

RESUMO

The study aimed to assess the marginal, axial, and internal adaptation, as well as the fracture resistance of zirconia-reinforced lithium silicate (ZLS) endocrowns with varying pulpal inlay extensions and marginal geometry. Sixty extracted maxillary first molar teeth were divided into six groups (n = 10) according to pulpal inlay extension and marginal configuration. The first three groups (J2, J3, and J4) utilized prepared teeth for endocrowns without ferrule design and 2 mm, 3 mm, and 4 mm pulpal extensions, respectively. The second three groups (F2, F3, and F4) utilized prepared teeth with 1 mm shoulder margins and 2 mm, 3 mm, and 4 mm pulpal extensions. The endocrowns were fabricated from ZLS blocks using CAD/CAM milling technology. After cementation, the specimens underwent thermal aging for 5000 cycles and were evaluated for marginal adaptation. Using a universal testing machine, the fracture resistance was tested under quasistatic loading (1 mm/min). Two-way ANOVA and the Tukey's post hoc test were employed for data analysis (p ≤ 0.05). The results of this study revealed that endocrowns without ferrule exhibited superior fracture strength than a 1 mm ferrule design p < 0.05, irrespective of the inlay depth. All designs with and without ferrule and all inlay depths showed clinically acceptable marginal and internal fit. The conventional endocrown design without ferrule and 2 mm inlay depth showed the lowest surface gap. The pulpal surface showed the highest discrepancy among all groups compared to the other surfaces. Endocrowns without ferrule are more conservative and have higher fracture strength than 1 mm ferrule designs; extending the inlay depth showed a significant increase in fracture resistance of the 1 mm ferrule design, but not for the conventional design without ferrule and 2 mm inlay depth. All groups exhibited a high auspicious fracture strength value for molar endocrown restorations.

5.
Saudi Dent J ; 36(2): 353-358, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38420004

RESUMO

Aims: The present study aimed to compare the fracture resistance and marginal adaptation of endocrowns fabricated using lithium disilicate (LDS) and zirconia-reinforced lithium silicate 9ZLS) ceramics by the computer-aided design and computer-aided manufacturing (CAD/CAM) technology. Materials and Methods: In this in vitro experimental study, 24 extracted mandibular first molars received standard endocrown preparation and were randomly assigned to two groups (n = 12) for the fabrication of endocrowns with ZLS (Suprinity) and LDS (IPS e.max CAD) ceramics. After scanning the teeth with a CAD scanner, endocrowns were designed by inLab Software version 15 (inLab SW 15) and prepared by an imes-icore 350i milling machine. The vertical marginal gap of endocrowns was measured under a stereomicroscope at three steps before and after cementation and after thermomechanical cycles. The fracture resistance of specimens was then measured by load application at a 45° angle. Mode of failure was also determined as reparable or irreparable. Data were analyzed using Pearson's correlation test and t-test. Results: The mean fracture resistance of ZLS endocrowns was significantly higher than that of LDS endocrowns (P = 0.000). The reparability of ZLS endocrowns was zero, while that of LDS endocrowns was 83.33 %. The vertical marginal gap was significantly smaller in ZLS than in LDS endocrowns at all three time points (P < 0.05). Also, the marginal gap increased by cementation and thermomechanical cycles in both groups. Conclusion: ZLS and LDS endocrowns both showed acceptable vertical marginal adaptation. ZLS had superior marginal adaptation and higher fracture resistance.

6.
BMC Oral Health ; 24(1): 113, 2024 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-38243249

RESUMO

PURPOSE: To investigate the effect of different occlusal reduction design on stress distribution and fracture resistance of different endocrown systems. MATERIAL AND METHODS: Sixty-four maxillary human premolars with endodontic treatment, prepared for endocrowns were divided into 2 groups (n = 32) according to the occlusal design: Butt joint preparation (B group) and Anatomical preparation (A group). Each group were subdivided into four groups according to ceramic systems: IPS E max CAD (EM group), monolithic zirconia (ZR group), Nacera Hyprid (NH group) and PEKKTON (PE group). After manufacturing of endocrowns and adhesive bonding the specimens were thermomechanically loaded and subsequently they were tested in a universal testing machine for evaluating the fracture resistance. The specimens failure mode was qualitatively assessed. The stress distribution in each group was assessed using three-dimensional finite element analysis (FEA). 1-way ANOVA and the Post Hoc Tukey HSD test were used to evaluate the data (a = .05). RESULTS: The fracture resistance values between the groups showed statistically significant variations. The B PE and A PE groups had a higher ratio of fracture resistance values. Regarding failure mode, ceramic endocrowns recorded mainly irreparable failures. FEA showed that anatomical occlusal preparation have reduced the stress concentration under all endocrown systems. CONCLUSION: Endocrowns could be used to restore endodontically treated maxillary premolars. PEKKTON endocrowns with anatomical preparations revealed most appropriate restoration. The tested new endocrown systems enhanced the biomechanical performance of the tooth. CLINICAL SIGNIFICANCE: The innovative endocrown systems (PEKK, Nacera Hyprid) can be seen as a promising choice for restoration of severely-destructed endodontic treated premolars, with less stress transmit to the residual tooth structure. Although the traditional endocrown technology might increase the longevity of tooth bonding, it shouldn't be used for clenching cases since the risk of failure is too great overall.


Assuntos
Coroas , Porcelana Dentária , Humanos , Porcelana Dentária/química , Dente Pré-Molar , Análise do Estresse Dentário , Falha de Restauração Dentária , Cerâmica/química , Teste de Materiais , Desenho Assistido por Computador
7.
J Prosthodont Res ; 68(1): 50-62, 2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-37286503

RESUMO

PURPOSE: This study performed a systematic review to assess the biomechanical behavior of all-ceramic endowcrowns fabricated using computer-aided design and computer-aided manufacturing (CAD/CAM) for the restoration of endodontically treated teeth. STUDY SELECTION: Three electronic databases (PubMed, Web of Science, and Scopus) were searched by operators specializing in health sciences databases searches to answer the following focused question based on the Population, Intervention, Comparison, Outcome (PICO) format: "Whether all-ceramic CAD/CAM endocrowns (Intervention) used to restore human endodontically treated teeth (Population) exhibit superior fracture resistance (Outcome) compared to non-CAD/CAM all-ceramic or non-ceramic endocrowns (Comparison)." The methodological quality assessment was performed using previously conducted systematic reviews of in vitro studies. The outcomes were expressed as the mean ± the standard deviation (SD). RESULTS: Seventeen in vitro studies were included. The materials used in these studies were lithium disilicate glass-ceramic, polymer-infiltrated ceramic, zirconia-reinforced lithium silicate glass-ceramic, resin/hybrid nanoceramics, zirconia-reinforced lithium silicate ceramics, and feldspathic ceramic. The fracture resistance of endocrowns using different ceramics varied as follows: (i) IPS e.max CAD (2863.62 ± 51.47 N), (ii) Vita Enamic (1952 ± 378 N), (iii) Vita Suprinity (1859 ± 588 N), (iv) Cerasmart (1981 ± 169.5 N), (v) LAVA Ultimate (2484 ± 464 N), (vi) Celtra Duo (1618.30 ± 585.00 N), and (vii) Cerec Blocs (236.29 ± 32.12 N). CONCLUSIONS: CAD/CAM all-ceramic endocrowns can withstand occlusal forces in the posterior region. All-ceramic endocrowns improve the fracture strength of endodontically treated teeth. Lithium disilicate crowns were commonly and successfully used in the included studies. More in vitro investigations that implement uniformity in material and measurement approaches are required to strengthen the evidence currently available in the literature regarding the durability of all-ceramic endocrowns.


Assuntos
Cerâmica , Desenho Assistido por Computador , Coroas , Humanos , Porcelana Dentária , Lítio , Teste de Materiais , Silicatos , Dente não Vital , Zircônio
8.
Cureus ; 15(12): e49947, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38058523

RESUMO

Endodontic treatment is often necessary in the field of dentistry. As the tooth structure is lost during such treatment, the tooth may become weaker and lose some of its mechanical qualities. Endodontically treated posterior teeth require cuspal coverage because of their anatomical features. Endocrowns are regarded as a suitable choice for restoring teeth that have undergone endodontic treatment. These restorations are recommended when there is a substantial loss of tooth structure, restricted interocclusal space, or a short clinical crown. They are also contraindicated in case of severe loss of tooth structure where adhesion is not applicable. Endocrowns require a specific preparation design that is distinct from the conventional crown. They can be manufactured by two methods: heat pressing or computer-aided design/computer-aided manufacturing (CAD/CAM). Moreover, several materials have been used in fabricating endocrown restoration. Lithium disilicate glass-ceramic is the most recommended material as it possesses excellent mechanical properties and esthetic results with the ability to bond to tooth structure. In conclusion, several kinds of literature recommend using them for molars. Further research is needed to evaluate this technique for premolar and anterior teeth.

9.
Med Pharm Rep ; 96(4): 358-367, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37970193

RESUMO

Introduction: The opportunity of using Endocrown-type restorations in the current prosthetic dentistry practice as an alternative to other, well-established methods of corono-radicular restorations and the evolving palette of adhesive materials has made these restorations more popular in the last few years. Objective: The purpose is to review the available literature about Endocrown restorations regarding mechanical properties - fracture strength and resistance, survival rate, the preparation design - marginal and internal adaptation, and esthetics. Method: The search was carried out on four databases: PubMed, Scopus (ScienceDirect), Web of Science, and Scielo using the following terms: "endocrowns", "endodontic crown", and" no buildup crown". Initially, a total of 163 articles published between 2015 and May 2021 were selected. After the duplicates, papers presented only as abstracts, articles in any other languages except English, and review articles were eliminated; a total of 72 articles remained to be considered for this review.After assessing the 72 considered articles, 37 were chosen as fit for this review. The reasons for the elimination of the other 35 articles were: their main focus was other than endocrowns, e.g., direct restorations, indirect restorations of vital teeth; case reports; study protocols. Results: From the 37 articles selected, 34 were focused on mechanical properties, including the influence of the preparation design, and three on survival rate, of which one also had a point of view regarding esthetics. Conclusions: The literature included in this review shows that endocrowns perform similarly or even better in some cases than other coronal restorations. However, this statement must be interpreted cautiously, given that most articles were in vitro or finite element analysis studies. Given the high degree of conflicting results found in the articles included in this review, the authors consider as reasonable to conclude that further studies are needed to confirm the feasibility of endocrowns and the best choice of material.

10.
J Funct Biomater ; 14(8)2023 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-37623666

RESUMO

To evaluate the fracture strength and the failure mode of endodontically treated molars restored with monolithic lithium disilicate and zirconia endocrowns and overlays. A total of 48 extracted mandibular molars were endodontically treated, decoronated 2 mm above the cementoenamel junction and divided into four 12-specimen groups. Group ELD: lithium disilicate endocrowns. Group EZ: monolithic zirconia endocrowns. Group OLD: lithium disilicate overlays. Group OZ: monolithic zirconia overlays. Overlays did not extend in the pulp chamber and endocrowns extended in the pulp chamber 2 mm. After adhesive bonding of the restorations, the specimens were subjected to thermocycling (×5000 cycles) and then to fracture resistance testing at lateral static loading (1 mm/min) at a universal testing machine. The failure mode of the specimens was qualitatively evaluated. Differences in means were compared using with t-tests for independent samples or Mann-Whitney test (p < 0.05). Weibull distribution analysis was also performed. Group ELD showed significantly higher fracture strength than all other groups (p = 0.001), and the highest Weibull modulus. Conclusions: Lithium disilicate endocrowns exhibit higher fracture strength and are more reliable compared to the other types of restorations examined. Endocrowns had more catastrophic failures compared to overlays.

11.
J Oral Biol Craniofac Res ; 13(5): 616-621, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37576802

RESUMO

Purpose: The limitations of foundation restorations have been reduced with the advent of endocrowns. Despite their success, the extent of endocrowns tooth preparation into the pulp chamber has not been fully explored in the literature. The study aimed to evaluate the clinical performance of endocrowns with 5 mm extended pulp chamber tooth preparations in Indian patients over a 1- year period using modified USPHS criteria. Methods: The observational study recruited 36 participants with definite criteria. Ceramic crown was planned for all the participants. Conventional endocrown tooth preparation was made with 5 mm pulpal extension. Clinical assessments were made at 0-, 6- and 12-months intervals using modified USPHS criteria. The data was statistically analyzed using Friedman test and Wilcoxon signed rank test. Results: One patient (2.8%) experienced loss of retention, marginal adaptation, and loss of anatomical form during 1-year follow up period. The majority of the participants (97.3%) reported no discomfort and high satisfaction. (P < .05) No opposing tooth wear was observed at 0- and 6-months. The results showed statistical significance in the parameters of retention, marginal adaptation, loss of anatomical form, and patient satisfaction. (P < .05). Conclusion: The clinical performance of endocrowns with extended pulp chamber preparation was satisfactory for a period of 12 months.

12.
Cureus ; 15(7): e41531, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37426406

RESUMO

INTRODUCTION: Endocrown restorations have increased in popularity in recent years due to the advancement of both adhesive and restorative materials. The clinical success of endocrowns depends on several factors, including preparation design, material selection, fracture resistance, and marginal adaptation. The aim of this in vitro study was to compare the fracture strength of endocrown restorations fabricated from three different computer-aided design (CAD)/computer-aided manufacturing (CAM) materials. METHODS: Thirty extracted mandibular first molars were selected. The teeth underwent conventional root canal treatment before being prepared for endocrown restoration. The teeth were allocated to three groups (n=10), corresponding to each of the three ceramic materials used to fabricate the endocrowns they would receive. The ceramic materials used were zirconia-reinforced lithium silicate glass-ceramic (VITA Suprinity, VITA Zahnfabrik, Bad Säckingen, Germany), polymer-infiltrated hybrid ceramic (VITA Enamic, VITA Zahnfabrik, Bad Säckingen, Germany), and lithium disilicate glass-ceramic (IPS e.max CAD, Ivoclar Vivadent, Schaan, Liechtenstein). The specimens were scanned, and the digital impressions were transferred into design software to construct the endocrowns. The endocrowns were then milled and cemented. A universal testing machine (5969L3504, Instron, USA) was used for the fracture strength test at a crosshead speed of 1 mm/min until catastrophic failure occurred. Statistical analysis was performed using IBM Corp. Released 2015. IBM SPSS Statistics for Windows, Version 23.0. Armonk, NY: IBM Corp. RESULTS: The one-way analysis of the variance test indicated a significant difference in the fracture strength between the different ceramic groups tested (P=0.037). The Tukey posthoc test showed that the IPS e.max CAD group had marginally higher fracture strength values than the VITA Enamic group (P=055). No significant differences in fracture strength values were found between the VITA Enamic and VITA Suprinity groups or between the VITA Suprinity and IPS e.max CAD groups (P>0.05). CONCLUSION: The reported fracture strength values for all the tested materials were higher than the strength required to resist masticatory forces. Therefore, endocrowns fabricated using VITA Enamic, IPS e.max CAD, and VITA Suprinity CAD/CAM materials present restorations with a clinically acceptable fracture strength.

13.
J Funct Biomater ; 14(5)2023 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-37233386

RESUMO

The aim of this systematic review was to summarize the results of the studies that have compared the physical and mechanical properties of lithium disilicate (LDS) endocrowns constructed for posterior teeth to those retained by post-and-core retention systems. The review was conducted following the PRISMA guidelines. The electronic search process was conducted on PubMed-Medline, Scopus, Embase and ISI Web of Knowledge (WoS) from the earliest available date till 31 January 2023. Additionally, the studies were assessed for their overall quality and risk of bias using the Quality Assessment Tool For In Vitro Studies (the QUIN). The initial search resulted in 291 articles, out of which, only 10 studies met the eligibility criteria. In all studies LDS endocrowns were compared with various kinds of endodontic posts and crowns made from other materials. There were no definite pattern or trends observed in the fracture strengths of tested specimens. There was no predilection observed in failure patters among the experimental specimens. No predilection was observed in the fracture strengths of LDS endocrowns when compared to post-and-core crowns. Furthermore, no differences in failure patterns could be observed when both types of restorations were compared. The authors propose standardized testing of endocrowns against post-and-core crowns in future studies. In conclusion, long-term clinical trials are advocated to compare the survival, failure and complication rates of LDS endocrowns and post-and-core restorations.

14.
BMC Oral Health ; 23(1): 207, 2023 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-37029396

RESUMO

BACKGROUND: The aim of the study was to investigate the effect of material and occlusal preparation design on the internal fit and marginal gap of endocrowns made of Polyether ether ketone (PEEK) and lithium disilicate. METHODS: 32 endocrowns were fabricated on prepared mandibular molars and divided into two groups (n = 16) according to the material. Group L: lithium disilicate and Group P: PEEK. Each group was further subdivided into two subgroups (n = 8) according to the occlusal preparation design: full occlusal coverage (LF and PF) and partial occlusal coverage (LP and PP). Samples were analyzed using microcomputed tomography (µCT) with a voxel size of 6 µm to evaluate internal fit, and an optical microscope was used to evaluate the marginal gap. Data were collected, tabulated, and statistically analyzed. Numerical data were described as mean and standard deviation and compared using the ANOVA test. The level of significance was set at α P ≤ 0.05. RESULTS: All groups' internal fit and marginal gaps values were within the acceptable clinical range. However, the lithium disilicates group recorded statistically significantly higher mean internal gap values than the PEEK groups. Regardless of the material, the difference between the two occlusal designs was not statistically significant in both internal fit and marginal gap records. CONCLUSION: Within the limitations of this study, PEEK endocrown restorations revealed better internal fit and marginal gap than lithium disilicate endocrown restorations. The marginal and internal fit of both lithium disilicate and PEEK endocrown restorations were within the clinically acceptable range. The occlusal preparation design had no influence on the internal fit and marginal gap of the endocrown restoration.


Assuntos
Cerâmica , Coroas , Humanos , Microtomografia por Raio-X , Desenho Assistido por Computador , Adaptação Marginal Dentária , Planejamento de Prótese Dentária/métodos , Éteres , Teste de Materiais
15.
Int J Comput Dent ; 26(1): 31-36, 2023 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-36825565

RESUMO

AIM: The present study aimed to investigate the effect of pulp chamber depth on the failure load and mode of failure of CAD/CAM endocrowns. MATERIALS AND METHODS: Thirty mandibular molars were sectioned above the cementoenamel junction (CEJ), followed by root canal treatment. Teeth were sectioned at a level of 1.5 mm above the CEJ, arranged from the lowest to the highest depths, and divided into three groups (n = 10): group SE: Shallow pulp chamber (1.42 to 2.17 mm); group IE: Intermediate pulp chamber (2.25 to 3.17 mm); group DE: Deep pulp chamber (3.33 to 5.17 mm). CAD/CAM endocrowns were fabricated by milling lithium disilicate ceramic blocks and were cemented using resin cement. Teeth were embedded in acrylic resin at 2 mm below the CEJ, and a compressive load was applied to create a 45-degree angled functional loading simulation until the occurrence of failure. RESULTS: The mean failure loads were highest in group DE (1893.75 ± 496.08 N) compared with groups IE (1103.71 ± 254.59 N) and SE (1084.63 ± 240.92 N), with statistically significant differences between group DE and both groups IE and SE (P < 0.001). Pearson correlation coefficient (PCC) revealed a strong positive correlation between the pulp chamber depth and failure load of the endocrowns. The failure mode for all samples was catastrophic failure. CONCLUSION: The pulp chamber depth affected the failure load of the teeth restored with endocrowns. The failure loads were higher in teeth with a greater pulp chamber depth. (Int J Comput Dent 2023;26(1): 31-0; doi: 10.3290/j.ijcd.b3818295).


Assuntos
Coroas , Cavidade Pulpar , Humanos , Falha de Restauração Dentária , Porcelana Dentária , Cerâmica , Cimentos de Resina , Teste de Materiais , Desenho Assistido por Computador , Análise do Estresse Dentário
16.
Clin Oral Investig ; 27(6): 2957-2968, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36781479

RESUMO

OBJECTIVES: To evaluate the effect of the remaining tooth structure and different CAD/CAM materials on the fatigue performance and failure mode of endodontically treated premolars restored with endocrowns. MATERIALS AND METHODS: Ninety maxillary premolars were endodontically treated and assigned into 6 groups (n = 15) according to the number of remaining axial walls (four, three, and two) and restorative materials (ultra-translucent zirconia 5Y-PSZ [KATANA UTML] and lithium disilicate [IPS e.max-CAD]). The specimens were subjected to cyclic fatigue loading test (initial load 200 N; 20 Hz). An incremental step load of 100 N per 10,000 cycles was applied until failure. The fatigue failure load (FFL) and number of failure cycles (CFFs) data were statistically analyzed with two-way ANOVA and Kaplan-Meier test (α = 0.05). Failed specimens were examined under a stereomicroscope 25 × and failure modes were determined. RESULTS: FFL and CFF were significantly influenced by restorative material (p < 0.05). 5Y-PSZ endocrowns showed significantly higher FFL when compared with lithium disilicate. The number of remaining walls did not affect the fatigue behavior or failure mode of the specimens. Of the lithium disilicate restorations, 51% had repairable failures, while 95% 5Y-PSZ restorations had non-repairable failures. CONCLUSIONS: Zirconia endocrowns showed better FFL than lithium disilicate endocrowns, regardless of the number of remaining axis walls. Lithium disilicate and 5Y-PSZ endocrowns showed FFL higher than the normal masticatory loads. CLINICAL RELEVANCE: Restoring endodontically treated premolars with endocrown could be a promising treatment, regardless of the remaining axial walls. However, precaution should be taken in material selection since it affects the fatigue resistance and failure mode.


Assuntos
Cerâmica , Coroas , Cerâmica/química , Dente Pré-Molar , Teste de Materiais , Falha de Restauração Dentária , Análise do Estresse Dentário , Propriedades de Superfície , Porcelana Dentária/química , Materiais Dentários , Desenho Assistido por Computador
17.
J Conserv Dent Endod ; 26(6): 627-633, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38292752

RESUMO

Purpose: This study aimed to assess the effect of preparation design on fracture resistance (FR) of endodontically treated maxillary premolars restored with lithium disilicate (LDS) endocrowns fabricated by the computer-aided design/computer-aided manufacturing (CAD/CAM) technology. Materials and Methods: In this in vitro, experimental study, 30 sound maxillary premolars were randomly assigned to three groups (n = 10) of control (no preparation), endocrown preparation with butt-joint design without ferrule, and endocrown preparation with ferrule (shoulder design with 1 mm height). After restoration fabrication and cementation, the teeth underwent thermocycling, were mounted with 45° angle, and subjected to compressive load in a universal testing machine to measure their FR. The mode of failure was also determined under a stereomicroscope. Data were analyzed using one-way ANOVA and Tukey's test (α =0.05). Results: The shoulder group showed the highest FR (1768.98 ± 386.1 N). The difference in FR was statistically significant among the three groups (P < 0.05). Pairwise comparisons revealed that the shoulder group had significantly higher FR than the butt-joint (P = 0.001) and control (P = 0.009) groups. However, the difference in FR between the butt-joint and control groups was not significant (P = 0.75). The mode of failure was not significantly different among the three groups (P > 0.05). Conclusions: Preparation design had a significant effect on FR of endodontically treated maxillary premolars restored with LDS CAD/CAM Endocrowns, such that addition of a short axial wall in shoulder group significantly increased the FR of endocrowns.

18.
J Pharm Bioallied Sci ; 14(Suppl 1): S39-S42, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36110800

RESUMO

Normally root canal-treated teeth are covered with crowns to prevent fracture, which becomes challenging in cases where the tooth is extensively damaged. In such instances, various restorative methods such as post-core and endocrowns have been in use. The former methodology in recent times is being discouraged owing to impending tooth weakening. Due to this reason, an uncommon type of reconstruction, endocrowns are preferred. We carried out a comparative review of restorations for endodontically treated molars.

19.
Int Endod J ; 55 Suppl 4: 1059-1084, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35808836

RESUMO

This narrative review will focus on a number of contemporary considerations relating to the restoration of root filled teeth and future directions for research. Clinicians are now more than ever, aware of the interdependence of the endodontic and restorative aspects of managing root filled teeth, and how these aspects of treatment are fundamental to obtaining the best long-term survival. To obtain the optimal outcomes for patients, clinicians carrying out endodontic treatment should have a vested interest in the restorative phase of the treatment process, as well as an appreciation for the structural and biomechanical effects of endodontic-restorative procedures on restoration and tooth longevity. Furthermore, the currently available research, largely lacks appreciation of occlusal factors in the longevity of root filled teeth, despite surrogate outcomes demonstrating the considerable influence this variable has. Controversies regarding the clinical relevance of minimally invasive endodontic and restorative concepts are largely unanswered with respect to clinical data, and it is therefore, all too easy to dismiss these ideas due to the lack of scientific evidence. However, conceptually, minimally invasive endodontic-restorative philosophies appear to be valid, and therefore, in the pursuit of improved clinical outcomes, it is important that the efficacies of these treatment protocols are determined. Alongside an increased awareness of the preservation of tooth structure, developments in adhesive bonding, ceramic materials and the inevitable integration of digital dentistry, there is also a need to evaluate the efficacy of new treatment philosophies and techniques with well-designed prospective clinical studies.


Assuntos
Restauração Dentária Permanente , Dente não Vital , Humanos , Restauração Dentária Permanente/métodos , Estudos Prospectivos , Raiz Dentária , Obturação do Canal Radicular/métodos , Dente não Vital/terapia
20.
Eur J Prosthodont Restor Dent ; 30(4): 252-261, 2022 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-35254011

RESUMO

PURPOSE: This double-blind randomized clinical trial (RCT) aimed to evaluate the 2-year survival rates of endocrowns and partial coverage ceramic restorations (PCCR) with fiber posts. MATERIAL AND METHODS: Forty (40) participants fulfilled the elegibility criteria, and they were randomly allocated in 2 groups: Endocrown or PCCR+post. The survival rates were assessed based on USPHS modified and radiographic examinations. A Chi-square test was used to assess the distribution of characteristics between groups. Kaplan-Meier and Log-rank tests were used to estimate the survival rate. To evaluate the association between survival of the restorations and the explanatory variables, the Multivariate Cox regression model was used. Only variables presenting p⟨0.20 were maintained in final model (α= 0.05). RESULTS: The highest 2-year survival rates were recorded for the Endocrown group (100%), whereas the PCCR+post group exhibited the lowest performance (66.7%). Most of the restoration failures was due to lack of marginal adaption, fracture, and recurrent caries. Cox Regression unadjusted analysis showed that only type of restoration presented a significant effect (p⟨0.20). Thus, adjusted analysis was not performed. CONCLUSIONS: Endocrowns appear to be a promising conservative restorative option and to be feasible and reliable approach restoring endodontically.


Assuntos
Coroas , Porcelana Dentária , Humanos , Falha de Restauração Dentária , Teste de Materiais , Cerâmica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA