RESUMO
To use scanning electron microscopy and energy dispersive X-ray spectroscopy to evaluate the metallurgical-chemical changes of WaveOne Gold (WOG) and R-Motion (RM), after multiple uses. The instruments were divided into groups (n = 8): WOG and RM-control groups, new instruments; WOG1 and RM1; WOG2 and RM2; WOG3 and RM3 after instrumentation of 1, 2 or 3 molars, respectively. Burrs occurred mainly in the control group and after the first use. The RM files were found to have a higher nickel content, which increased during reuse, and a decrease in oxygen content with increasing reuse, in addition to calcium impregnation, which occurred in greater amounts in the corrosion areas in the WOG files. The presence of topographic and chemical changes was demonstrated, indicating that caution should be taken when reusing endodontic instruments to avoid fractures.
RESUMO
The chemical composition of COVID test swabs has not been examined beyond the manufacturer's datasheets. The unprecedented demand for swabs to conduct rapid lateral flow tests and nucleic acid amplification tests led to mass production, including 3D printing platforms. Manufacturing impurities could be present in the swabs and, if so, could pose a risk to human health. We used scanning electron microscopy and energy dispersive X-ray (EDX) spectroscopy to examine the ultrastructure of seven assorted brands of COVID test swabs and to identify and quantify their chemical elements. We detected eight unexpected elements, including transition metals, such as titanium and zirconium, the metalloid silicon, as well as post-transition metals aluminium and gallium, and the non-metal elements sulphur and fluorine. Some of the elements were detected as trace amounts, but for others, the amount was close to reported toxicological thresholds for inhalation routes. Experimental studies have shown that the detrimental effects of unexpected chemical elements include moderate to severe inflammatory states in the exposed epithelium as well as proliferative changes. Given the massive testing still being used in the context of the COVID pandemic, we urge caution in continuing to recommend repeated and frequent testing, particularly of healthy, non-symptomatic, individuals.
RESUMO
Abstract This study compared the pH and calcium ion release of calcium silicate- (Bio-C Temp) and calcium hydroxide-based (Ultracal XS) medications. Intracanal remnants of both medications were also evaluated using SEM-EDS after the removal protocol. Thirty-five bovine teeth were prepared. Fifteen were filled with Bio-C Temp and 15 with Ultracal XS. Five remained without intracanal medication (control group). Five samples from each experimental time (i.e.. 24, 72, and 168 hours) were used to measure pH and calcium ions release using a digital pH meter and microplate reader, respectively. Afterward, the peaks of the chemical elements composing both medications were analyzed in SEM-EDS. One-way ANOVA and Tukey's post hoc test analyzed the pH and calcium ion release data. Student's t-test compared the medications in each experimental time. SEM-EDS described the percentage of chemical elements in the samples. Bio-C Temp and Ultracal XS showed a significant pH increase from 24 to 168 hours (p<0.05). Ultracal XS showed a higher pH value at 24 hours than Bio-C Temp (p<0.05) but were similar at 72 and 168h (p > 0.05). Calcium ion release did not depend on the experimental period (p > 0.05). Bio-C Temp showed lower calcium ions release than Ultracal XS at 24 hours (p<0.05). SEM-EDS analyses showed the remains of both medications, but the concentration of Si, Al, and W ions was present only in the calcium silicate-based medication. Bio-C Temp presented alkaline pH and a satisfactory calcium ion release over the time. The remaining of both medications were present after the protocols for paste removal.
Resumo Este estudo comparou o pH e a liberação de íons cálcio de medicações intracanais a à base de silicato de cálcio (Bio-C Temp) e à base de hidróxido de cálcio (Ultracal XS). Remanescentes de ambas as medicações também foram avaliados usando microscopia eletrônica de varredura e espectroscopia de dispersão de energia após o protocolo de remoção. Trinta e cinco dentes bovinos foram preparados. Quinze dentes foram preenchidos com Bio-C Temp e 15 com Ultracal XS. Cinco permaneceram sem medicação intracanal (grupo controle). Cinco amostras de cada tempo experimental (ou seja, 24, 72 e 168 horas) foram usadas para medir o pH e a liberação de íons de cálcio usando um medidor de pH digital e um leitor de microplacas, respectivamente. Em seguida, os picos dos elementos químicos que compõem os dois medicamentos foram analisados em microscopia eletrônica de varredura e por espectroscopia de dispersão de energia. Os testes One-way ANOVA e post hoc de Tukey analisaram os dados de pH e liberação de íons cálcio. O teste t de Student comparou as medicações em cada tempo experimental. A microscopia eletrônica de varredura e a espectroscopia de dispersão de energia descreveu a porcentagem de elementos químicos nas amostras. O Bio-C Temp e o Ultracal XS mostraram um aumento significativo de pH de 24 a 168 horas (p<0,05). O Ultracal XS apresentou um valor de pH mais alto em 24 horas do que o Bio-C Temp (p<0,05), mas foi semelhante em 72 e 168h (p > 0,05). A liberação de íons cálcio não dependeu do período experimental (p> 0,05). O Bio-C Temp apresentou menor liberação de íons de cálcio do que Ultracal XS em 24 horas (p<0,05). As análises de microscopia eletrônica de varredura e espectroscopia de dispersão de energia mostraram remanescentes de ambas as medicações, mas a concentração de íons Si, Al e W estavam presentes apenas na medicação à base de silicato de cálcio. O Bio-C Temp apresentou pH alcalino e maior liberação de íons cálcio. Remanescentes de ambas as medicações estiveram presentes após os protocolos de remoção da pasta.
RESUMO
This study provides a comprehensive account of the various types of calcium oxalate crystals found in the genus Baccharis and assesses the exceptional value of crystal macropatterns for the taxonomy of the genus. The morphotype, occurrence, and chemical composition of the crystals found in the stems and leaves are studied. The 44 species included in this study were selected based on a broad phylogeny-based sampling covering seven subgenera and 31 sections. These species were chosen to represent all the main phylogenetic lineages of Baccharis; thus, the sampling also represents a comprehensive coverage concerning evolutionary significance for such a large and environmentally and economically important plant group. The samples were analyzed by light microscopy, scanning electron microscopy (SEM), and energy-dispersive x-ray spectroscopy (EDS). Several morphotypes of crystals, including druses, crystal sand, styloids and prisms, were present. Based on their chemical composition, the crystals were classified as pure calcium oxalate, mixtures of oxalates and sulfates, and mixtures of oxalates, sulfates, and silica. The crystal macropatterns observed in this study aid in species identification and provide novel data for the taxonomy of Baccharis. RESEARCH HIGHLIGHTS: Most species of Baccharis have a specific crystalline pattern. Each species produces a crystal morphotype or a set of morphotypes specific to it. The crystals observed are formed by calcium oxalate.
Assuntos
Baccharis , Oxalato de Cálcio , Oxalato de Cálcio/química , Filogenia , Microscopia Eletrônica de Varredura , Oxalatos , SulfatosRESUMO
This study aimed to compare three endodontic rotary systems. The new Genius Proflex (25/0.04), Vortex Blue (25/0.04), and TruNatomy (26/0.04v) instruments (n = 41 per group) were analyzed regarding design, metallurgy, and mechanical performance, while shaping ability (untouched canal walls, volume of removed dentin and hard tissue debris) was tested in 36 anatomically matched root canals of mandibular molars. The results were compared using one-way ANOVA, post hoc Tukey, and Kruskal−Wallis tests, with a significance level set at 5%. All instruments showed symmetrical cross-sections, with asymmetrical blades, no radial lands, no major defects, and almost equiatomic nickel−titanium ratios. Differences were noted in the number of blades, helical angles, cross-sectional design, and tip geometry. The Genius Proflex and the TruNatomy instruments had the highest and lowest R-phase start and finish temperatures, as well as the highest and lowest time and cycles to fracture (p < 0.05), respectively. The TruNatomy had the highest flexibility (p < 0.05), while no differences were observed between the Genius Proflex and the Vortex Blue (p > 0.05). No differences among tested systems were observed regarding the maximum torque, angle of rotation prior to fracture, and shaping ability (p > 0.05). The instruments showed similarities and differences in their design, metallurgy, and mechanical properties. However, their shaping ability was similar, without any clinically significant errors. Understanding these characteristics may help clinicians to make decisions regarding which instrument to choose for a particular clinical situation.
RESUMO
Homeopathy is highly controversial. The main reason for this is its use of very highly dilute medicines (high homeopathic potencies, HHP), diluted beyond the Avogadro/Loschmidt limit. Research using Nano Tracking Analysis has demonstrated the presence of particles in HHPs. This study aims to verify the results of a previous publication that identified the ionic composition of these particles in all dilutions. We used Scanning Electron Microscopy & Energy Dispersive X-Ray Spectroscopy (SEM-EDX) to examine dilutions of a commonly used homeopathic medicine, an insoluble metal, Cuprum metallicum, for the presence of particles (NPs). The homeopathic medicines tested were specially prepared according to the European pharmacopoeia standards. We compared the homeopathic dilutions/dynamizations of copper with simple dilutions and dynamized lactose controls. We observed an ionic diversity common to all preparations including HHPs but also significant differences in the relative quantity of each ion between manufacturing lines of homeopathic copper and lactose controls. The probability that the observed differences could have occurred chance alone (especially above Avogadro limit) can be rejected at p < 0.001. The essential component of these homeopathic medicines is sodium hydrogen carbonate, modulated by some other elements and by its quantity, size and shape. Homeopathic medicines made of Cuprum metallicum do contain material with a specific ionic composition even in HHPs diluted beyond the Avogadro/Loschmidt limit. This specificity can be attributed to the manufacturing process. This material demonstrates that the step-by-step process (dynamized or not) does not match the theoretical expectations of a dilution process. The starting material and dilution/dynamization method influences the nature of these NPs. Further measurements are needed on other raw materials using the same controls (solvent and simply diluted manufacturing lines) to support these findings. The role of sodium bicarbonate must be carefully studied in the future.
Assuntos
Dinamização , Farmacotécnica Homeopática , Nanopartículas , Espectrometria por Raios X , Microscopia Eletrônica de Varredura , Cuprum , Bicarbonato de Sódio , Cobre , LactoseRESUMO
Homeopathy is controversial because using highly dilute medicines (high homeopathic potencies, HHP) beyond the Avogadro/Loschmidt limit. Previous publications [1,2] using NMR relaxation revealed the involvement of nanobubbles and/or nanoparticles and/or nanometric superstructures in high potentizations. Nano Tracking Analyse (NTA) demonstrated the presence of particles in HHPs [3,4]. WithSEM-EDX [5] we observed an ionic diversity common to all preparations including HHPs and significant differences in the relative quantity of each ion between different homeopathic manufacturing lines and controls. FTIR spectroscopy [6] shows that the molecular composition is that of carbonates, primarily sodium bicarbonate.Methods:To observe the materiality of homeopathic medicines a multidisciplinary approach is necessary. In collaboration with several universities,we canobserve these medications with NMR, NTA, SEM-EDX, FTIR, pH,and EPA. Results:The essential component of all already studied homeopathic medicines is sodium hydrogen carbonate modulated by some other elements in a specific quantity, size,and shape. The probability that the observed results could have occurred just by random chance can be rejected(significantlyabove the Avogadro limit) p < 0,001.Conclusions:The homeopathic medicines do contain material with a specific ionic composition even in HHPs diluted beyond the Avogadro/Loschmidt limit. This specificity can be attributed to the manufacturing process. These results demonstrate that the step-by-step process (dynamized or not) does not match the theoretical expectations in a dilution process. The starting material and dilution/dynamization method influencethe nature of these NPs. The role of carbonates and sodium bicarbonate must be carefully studied in the future. Its aqueous solution is alkaline in nature but itis an amphoteric compound, which means that the compound has both acidic as well as alkaline character. The reaction with acids results in sodium salts and carbonic acid and the reaction with the basic solution producescarbonates and water. Specific electric fields are indeed detectable.
Assuntos
Materia Medica , Dinamização , Nanopartículas , Microscopia Eletrônica de Varredura , Bicarbonato de Sódio/análiseRESUMO
Analytical studies of nanoparticles (NPs) are frequently based on huge datasets derived from hyperspectral images acquired using scanning transmission electron microscopy. These large datasets require machine learning computational tools to reduce dimensionality and extract relevant information. Principal component analysis (PCA) is a commonly used procedure to reconstruct information and generate a denoised dataset; however, several open questions remain regarding the accuracy and precision of reconstructions. Here, we use experiments and simulations to test the effect of PCA processing on data obtained from AuAg alloy NPs a few nanometers wide with different compositions. This study aims to address the reliability of chemical quantification after PCA processing. Our results show that the PCA treatment mitigates the contribution of Poisson noise and leads to better quantification, indicating that denoised results may be reliable from the point of view of both uncertainty and accuracy for properly planned experiments. However, the initial data need to be of sufficient quality: these results can only be obtained if the signal-to-noise ratio of input data exceeds a minimal value to avoid the occurrence of random noise bias in the PCA reconstructions.
RESUMO
Freshwater is a limited resource, which has driven the development of new purification and water-reuse technologies. One promising technology for water treatment is membrane distillation (MD). One of the main problems of MD, and of many desalination technologies, is membrane fouling, which reduces the performance of the membrane. This work presents a mathematical model that aims to predict distillate fluxes in direct-contact MD when fouling occurs as salts are deposited onto the membrane surface, forming an inorganic fouling layer. The mathematical model uses a heat- and mass-transfer formulation for prediction of the distillate flux under steady state conditions, and it is combined with the cake-filtration theory to represent the distillate fluxes after the onset of membrane fouling. Model results agree well with experimental observation of distillate fluxes, both before (~12-14 kg m-2 h-1) and after the onset of membrane fouling, with root-mean-square errors smaller than 1.4 kg m-2 h-1 in all the experiments. These results suggest that the cake-filtration theory can be used to represent water flux decline in MD membranes prone to inorganic fouling. From our experiments and from the modelling exercise, we found that the onset of membrane failure was relatively constant; the precipitation reaction constant is conditioned by the physicochemical interaction between the feed solution and the membrane; and the rate of flux decline after membrane fouling depends on flow conditions as well as on the precipitation compound. However, the proposed model has limitations that must be addressed in future investigations to validate it under a wider range of operating conditions, for membranes composed by other materials and with different feed solutions to address organic, biological, and/or colloidal fouling, which typically occur under real conditions.
RESUMO
Introduction: Echinoderm coelomocytes have traditionally been investigated through a morphological approach using light microscopy, which relies on the idea of constant cell shape as a stable character. However, this can be affected by biotic or abiotic conditions. Objective: To analyze if the consistency in cell morphology offered by the cytocentrifugation method, might be used as a convenient tool to study echinoderm coelomocytes. Methods: Cells of Echinaster (Othilia) brasiliensis (Asteroidea), Holothuria (Holothuria) tubulosa (Holothuroidea), Eucidaris tribuloides, Arbacia lixula, Lytechinus variegatus, and Echinometra lucunter (Echinoidea) were spread on microscope slides by cytocentrifugation, stained, and analyzed through light microscopy. Additionally, fluorescence microscopy, scanning electron microscopy, and energy-dispersive x-ray spectroscopy were applied to cytospin preparations, to complement the analysis of granular and colorless spherulocytes of Eucidaris tribuloides. Results: Altogether, 11 cell types, including phagocytes, spherulocytes, vibratile cells, and progenitor cells were identified in the samples analyzed. The granular spherulocyte, a newly-described cell type, was observed in all Echinoidea and was very similar to the acidophilic spherulocytes of Holothuria (Holothuria) tubulosa. Conclusions: Cytocentrifugation proved to be versatile, either as the main method of investigation in stained preparations, or as a framework on which other procedures may be performed. Its ability to maintain a constant morphology allowed accurate correspondence between live and fixed/stained cells, differentiation among similar spherulocytes as well as comparisons between similar cells of Holothuroidea and Echinoidea.
Introducción: Los celomocitos de equinodermos se han investigado tradicionalmente a través de un enfoque morfológico utilizando microscopía óptica, que se basa en la idea de la forma celular constante como un carácter estable. Sin embargo, esto puede verse afectado por condiciones bióticas o abióticas. Objetivo: Analizar si la consistencia en la morfología celular que ofrece el método de citocentrifugación podría utilizarse como una herramienta conveniente para estudiar los celomocitos de equinodermos. Métodos: Células de Echinaster (Othilia) brasiliensis (Asteroidea), Holothuria (Holothuria) tubulosa (Holothuroidea), Eucidaris tribuloides, Arbacia lixula, Lytechinus variegatus y Echinometra lucunter (Echinoidea) se esparcieron en portaobjetos de microscopio por citocentrifugación, se tiñeron y analizaron mediante microscopía óptica. Adicionalmente, se aplicó microscopía de fluorescencia, microscopía electrónica de barrido y espectroscopía de rayos X con dispersión de energía a las preparaciones de citoespina, para complementar el análisis de los esferulocitos granulares e incoloros de Eucidaris tribuloides. Resultados: En total, se identificaron en las muestras analizadas 11 tipos de células, incluidos fagocitos, esferulocitos, células vibrátiles y células progenitoras. El esferulocito granular, un tipo de célula recién descrito, se observó en todos los Echinoidea y fue muy similar a los esferulocitos acidófilos de Holothuria (Holothuria) tubulosa. Conclusiones: La citocentrifugación demostró ser un método bastante versátil, ya sea como el método principal de investigación en preparaciones teñidas o como un marco en el que se pueden realizar otros procedimientos. Su capacidad para mantener una morfología constante permitió una correspondencia precisa entre las células vivas y las células fijas/teñidas, la diferenciación entre esferulocitos similares, así como comparaciones entre células similares de Holothuroidea y Echinoidea.
Assuntos
Animais , Espectrometria por Raios X/métodos , Equinodermos/microbiologia , Centrifugação/instrumentação , Forma do Núcleo CelularRESUMO
Objectives: This study aimed to assess the effect of the polishing procedure and surface sealant application on the fluoride release of restorative materials. Material and Methods: The groups were consisted of using five different restorative materials were employed: Beautifil II, GCP Glass Fill, Amalgomer CR, Zirconomer and Fuji IX GP. 30 disk-shaped specimens (8x2 mm) were prepared from each material. Each group was subdivided into three groups considering finishing procedures: Mylar strip, polishing with Super-Snap discs, G-Coat Plus application after polishing with Super-Snap discs. The amount of fluoride released into distilled water was measured using a fluoride ion-selective electrode and ion analyzer after 24 hours, followed by measurement on days 3, 7, 15, 21, and 28. Surface analysis of the materials was performed with SEM (Scanning Electron Microscopy) and EDS (Energy Dispersive X-ray Spectroscopy). The data were statistically analyzed using two-way repeated measure ANOVA and LSD test (p=0.05). Results: The highest amount of fluoride released was measured after the first 24 h for all materials. Beautifil II released less fluoride than other materials in all measurement periods (p<0.05). After polishing, the amount of fluoride released from all materials except Beautifil II increased (p<0.05). The application of G-Coat Plus did not impact the amount of fluoride release of any materials (p>0.05). EDS analysis showed the most percentage of oxygen in all materials. Conclusion: The polishing procedure might induce an increase in fluoride release of glass ionomer-based materials, and the application of G-Coat Plus cannot affect the amount of fluoride release. (AU)
Objetivos: Este estudo teve como objetivo avaliar o efeito do procedimento de polimento e aplicação de selante superficial na liberação de flúor de materiais restauradores. Material e Métodos: Os grupos consistiram na utilização de cinco materiais restauradores diferentes: Beautifil II, GCP Glass Fill, Amalgomer CR, Zirconomer e Fuji IX GP. Trinta espécimes em forma de disco (8x2 mm) foram preparados a partir de cada material. Cada grupo foi subdividido em três grupos considerando os procedimentos de acabamento: tira Mylar, polimento com discos Super-Snap, aplicação de G-Coat Plus após polimento com discos Super-Snap. A quantidade de flúor liberada na água destilada foi medida usando um eletrodo íon-seletivo de fluoreto e analisador de íons após 24 horas, seguido pela medição nos dias 3, 7, 15, 21 e 28. A análise da superfície dos materiais foi realizada com MEV (Microscopia Eletrônica de Varredura) e EDS (Espectroscopia de Energia Dispersiva de Raios-X). Os dados foram analisados estatisticamente usando ANOVA de dois fatores com medidas repetidas e teste LSD (p = 0,05). Resultados: A maior quantidade de flúor liberado foi medida após as primeiras 24 horas para todos os materiais. O Beautifil II liberou menos flúor do que outros materiais em todos os períodos avaliados (p <0,05). Após o polimento, a quantidade de flúor liberada de todos os materiais, exceto Beautifil II, aumentou (p <0,05). A aplicação de G-Coat Plus não afetou a quantidade de liberação de flúor de nenhum material (p> 0,05). A análise por EDS revelou a maior porcentagem de oxigênio em todos os materiais. Conclusão: O procedimento de polimento pode induzir um aumento na liberação de flúor de materiais à base de ionômero de vidro, e a aplicação de G-Coat Plus não pode afetar a quantidade de liberação de flúor (AU)
Assuntos
Espectrometria por Raios X , Fluoretos , Cimentos de Ionômeros de VidroRESUMO
Energy dispersive X-ray spectroscopy (EDS) is a powerful technical tool used in the biomedical field to investigate the proportion of chemical elements of interest in research, such as heavy metal bioaccumulation and the enzymatic cofactors and nanoparticle therapy in various pathologies. However, the correct evaluation of the proportion of the elements is subject to some factors, including the method of sample preservation. In this study, we seek to investigate the effect of biological tissue preservation methods on the proportion of chemical elements obtained by the EDS methodology. For such, we used EDS to measure the proportion of chemical elements with biomedical interest in preserved livers, using three common methods for preserving biological tissues: (a) freezing, (b) paraformaldehyde fixative solution, and (c) Karnovsky solution. We found an increased level of sodium and reduced contents of potassium and copper in samples fixed in fixative solutions, when compared to frozen samples (p < 0.05). Our data indicate that preservation methods can change the proportion of chemical elements in biological samples, when measured by EDS. Frozen preservation should be preferred to retain the actual chemical content of samples and allow a correct assessment of the proportion of their elements.
Assuntos
Fígado/química , Metais Alcalinos/análise , Metais Alcalinoterrosos/análise , Metais Pesados/análise , Espectrometria por Raios X , Preservação de Tecido , Animais , Masculino , CamundongosRESUMO
The aim of this study was to evaluate the chemical and morphological effects of different lasers as a final surface treatment for endodontic therapy through energy dispersive X-ray spectroscopy (EDS) and scanning electron microscopy (SEM) respectively. Twenty-five maxillary canines were selected and instrumented with K3 system. Roots were randomly distributed into five groups (n = 5) according to the surface treatment: GI (distilled water), GII (NaOCl + EDTA), GIII (NaOCl + EDTA + 980 nm diode laser), GIV (NaOCl + EDTA+ 1,064 nm Nd:YAG laser), and GV (NaOCl + EDTA+ 2,780 nm Er, Cr:YSGG laser). Lasers were applied for 20 s and samples were bisected, exposing the treated surface and then subjected to elements quantification by EDS and morphological evaluation by scanning electron microscope (SEM). EDS data were submitted to ANOVA-two way, and SEM scores were submitted to two-way Kruskal-Wallis and Dunn's tests. The EDS analysis showed no difference for the chemical elements and Ca/P ratio between groups (p > .05). Statistical analysis showed more intense results for GV and less intense results for GI (p < .05). The GIII showed an amorphous organic matrix surface, while GV provided greater removal of intertubular dentin forming craters, and GIV promoted dentin fusion. The EDS method used in this study was not able to verify any chemical changes in root canal dentin; Nd:YAG, Er, Cr:YSGG, and 980 nm diode laser were capable of modifying the dentin morphology, correlating characteristics features for each one, which are essential clinical knowledge to establish the correct indication for each case. RESEARCH HIGHLIGHTS: EDS was not able to verify any chemical changes in root canal dentin after 980 nm diode, Nd:YAG and Er;Cr:YSGG laser treatments Nd:YAG, Er, Cr:YSGG, and 980 nm diode laser modified dentin morphology, correlating characteristics features for each one.
Assuntos
Dente Canino/efeitos da radiação , Dentina/efeitos da radiação , Terapia com Luz de Baixa Intensidade , Raiz Dentária/efeitos da radiação , Dente não Vital , Dente Canino/anatomia & histologia , Dente Canino/química , Dentina/anatomia & histologia , Dentina/química , Humanos , Microscopia Eletrônica de Varredura , Espectrometria por Raios X , Propriedades de Superfície/efeitos da radiação , Raiz Dentária/anatomia & histologia , Raiz Dentária/químicaRESUMO
Abstract Trans-endodontic implants are an artificial extension through root apex anchored in periradicular bone tissue. The aim is to improve the crown-root ratio and to provide stability to dental organ present. Zirconium oxide (ZrO2) is a material of great technological importance, having good natural color, high strength, high toughness, high chemical stability, does not suffer any corrosion, chemical and microbial resistance and excellent esthetic properties. Objective: The aim of this study was to evaluate chemical and microscopy of surface conditions of ZrO2 trans-endodontic implant. Materials and Methods: A blocks of ZrO2 were manufactured for produce trans-endodontic implants and divided in two groups: monoclinic and tetragonal phase. They were evaluated using Scanning Electroning Microscope (SEM), EnergyDispersive X-ray Spectroscopy (EDS), and Atomic Force Microscope (AFM) and Vickers Micro hardness. Results: The Monoclinic phase through AFM analysis showed roughness Ra = 0.320μm, whereas in the Tetragonal phase was 0.126μm, SEM/EDX indicated that the phases are not properly uniform and the addition of the Yttrium to favor the stabilization of the Tetragonal phase. The Vickers hardness analysis showed a value of 1500HV. Conclusion: The characterization of the surface of trans-endodontic zirconium oxide implants provides a guideline to know the surface characteristics of the material, since a greater roughness on the surface of the implant will favor the Osseo-integration capacity.
Resumen Los implantes trans-endodónticos son una extensión artificial a través del ápice radicular anclado en el tejido óseo periradicular. El objetivo es mejorar la relación corona-raíz y proporcionar estabilidad al órgano dental presente. El óxido de zirconio (ZrO2) es un material de gran importancia tecnológica, con buen color natural, alta resistencia, alta tenacidad, alta estabilidad química, no sufre corrosión, resistencia química y microbiana y excelentes propiedades estéticas. Objetivo: El objetivo de este estudio fue evaluar las condiciones superficiales de ZrO2 para su aplicación clínica a los implantes transendodónticos. Materiales y Métodos: se trituraron bloques de ZrO2 en implantes trans-endodónticos y se dividieron en: monoclínico y tetragonal. Luego se evaluaron mediante microscopía electrónica de barrido (SEM), espectroscopia de rayos X de energía dispersiva (EDS) y microscopio de fuerza atómica (AFM) y microdureza vickers. Resultados: La fase monoclínica a través del análisis AFM presenta Ra = 0.320 μm, mientras que en la fase Tetragonal es 0.126 μm, SEM / EDS muestra que las fases no son adecuadamente uniformes y la adición del Ytrio para favorecer la estabilización de la fase tetragonal. El análisis de microdureza mostro un valor de 1500HV. Conclusión: La caracterización de la superficie de los implantes trans-endodónticos de óxido de zirconio, brinda una pauta para conocer las características superficiales del material, ya que al haber una mayor rugosidad en la superficie del implante se verá favorecida la capacidad de oseointegración.
Assuntos
Espectrometria por Raios X , Zircônio/uso terapêutico , Implantes Dentários/microbiologiaRESUMO
ABSTRACT The present work provides a comparative account of the morpho-anatomy of six species of Eucalyptus, namely E. badjensis Beuzev. & Welch, E. benthamii Maiden & Cambage, E. dunnii Maiden, E. grandis W.Hill, E. globulus Labill. and E. saligna Sm., Myrtaceae. Leaf samples of these six species were investigated by light and scanning electron microscopy. The observed microscopic features that can be useful in the identification and quality control of the studied species include the morphology of epicuticular waxes, presence of prismatic crystals on the leaf surface, leaf midrib shape and arrangement of its vascular system, and the presence or absence of the sclerenchymatous fiber caps in the vascular bundle.
RESUMO
OBJECTIVES: This in vitro study evaluated the effect of microparticles (TMPmicro) or nanoparticles (TMPnano) TMP associated with fluoride (F) in toothpaste formulations on the obliteration of dentinal tubules (DT). MATERIALS AND METHODS: The dentinal tubules of bovine dentin blocks were unobstructed by immersion in 37% phosphoric acid solution. Blocks (n = 20/group) underwent mechanical brushing (2×/day) during 7 days with toothpastes: placebo, 1100 ppm F, and 1100 with 3% TMPmicro or 3% TMPnano. After that, ten blocks of each group were immersed in citric acid (pH 3.2) for 1 min. The number, diameter and area of unobstructed DT, atomic % of chemical elements from precipitates, and the mineral concentration were quantified. Data were submitted to two-way ANOVA, followed by Student-Newman-Keuls test (P < 0.05). RESULTS: Toothpastes containing TMPmicro and TMPnano promoted greater obliteration of DT and greater mineral concentration compared to other groups (P < 0.05). Placebo and 1100 ppm F group presented similar obliteration but 1100 ppm F group promoted higher mineral concentration. Higher Ca/P ratios were observed in groups treated with TMP; the acid challenge reduced Ca/P ratio for all groups. The atomic % of C and N was significantly lower for TMP toothpastes before acid challenge, but increased afterwards. CONCLUSIONS: It was concluded that the addition of TMPmicro or TMPnano to F toothpastes produced greater obliteration of dentinal tubules and higher mineral concentration when compared with 1100 ppm F. CLINICAL RELEVANCE: By the addition of TMP, fluoride toothpastes may occlude the dentinal tubules, with potential to reduce dentin hypersensitivity.
Assuntos
Dentina/efeitos dos fármacos , Fluoretos/química , Polifosfatos/química , Escovação Dentária , Cremes Dentais/química , Animais , Bovinos , Sensibilidade da Dentina/prevenção & controle , Técnicas In Vitro , Nanopartículas , Tamanho da PartículaRESUMO
Aim: This study characterized the implant surfaces available on the Brazilian market in terms of topography, chemical composition, and roughness. Methods: The following brands were selected according to their surfaces: Kopp (Ko), Signo Vinces (Sv), Neodent (Ne), Osseotite (Os) NanoTite (Nt), SIN (Si), Titanium Fix (Tf), conventional Straumann (Str), Active SLA (SLA). The morphological analysis and the alloy impurities and implant surface contaminants were analyzed by SEM-EDS. Surface roughness parameters and 3-D reconstructions were obtained by laser microscopy (20x). Two distinct areas were evaluated: i) the cervical portion (no surface treatment), and ii) the middle third (treated surface). Results: The characterization of the implant surfaces by SEM showed morphological differences between the thread geometries and surface morphology at 800x and 2000x magnification. The EDS elemental analysis showed a predominance of titanium (Ti) for all implants. The SLA surface showed only peaks of Ti while other implants brands showed traces of impurities and contaminants including Al, C, PR, F, Mg, Na, Ni, O, P, and SR. The implant surface roughness in the cervical portion did not exceed Ra 0.51.0 µm, constituting a minimally rough surface and obtaining acceptable standards for this region. Only Nt, Str, and SLA presented Ra above 2 µm in the middle third area showing a rough surface favorable for osseointegration. Conclusion: This study concluded that there is no established standard for morphology, chemical composition and implant surface roughness that allows a safe comparison between the available dental implant surfaces. National implant brands generally contain more impurities and surface contaminants than their international counterparts and were consequently more sensitive to the surface treatment techniques
Assuntos
Espectrometria por Raios X , Propriedades de Superfície , Implantes DentáriosRESUMO
The aim of this study was to evaluate the effect of Er:YAG laser for selective removal of carious lesion, followed by biomodification with chitosan gel where the subsurface microhardness, chemical composition, and morphological changes of the residual caries-affected dentin were examined. Artificial dentinal lesions were created by pH-cycling method (14 days) in 104 bovine specimens (5 × 5 mm). Specimens were randomly divided according to the carious removal method: bur (low-speed handpiece) or Er:YAG laser (250 mJ/4 Hz). Specimens were treated with 35% phosphoric acid and were subdivided into two groups according to dentin biomodification: without chitosan (control) and 2.5% chitosan. Forty specimens were restored with an adhesive system and composite resin. Subsurface microhardness tests were performed in sound dentin, caries-affected dentin, residual caries-affected dentin, and after the restoration. The other 64 specimens were subjected to SEM-EDS atomic analysis. Data were statistically analyzed (p < 0.05). After the Er:YAG laser excavation, the microhardness value of residual caries-affected dentin was higher (p < 0.05) than bur-treated dentin. A significant decrease in the amount of Ca, P, and Ca/P ratio was found after the removal of carious lesions with Er:YAG laser (p < 0.05). The biomodification with chitosan did not influence the microhardness and atomic percentage of Ca, P, and Ca/P ratio of residual caries-affected dentin (p > 0.05). SEM analysis showed morphological changes on residual caries-affected dentin (p > 0.05). The selective removal of carious dentin with Er:YAG laser increased microhardness of residual caries-affected dentin, changing its surface morphology and chemical composition. The biomodification with chitosan did not influence the structural and chemical composition of residual caries-affected dentin.
Assuntos
Quitosana/farmacologia , Cárie Dentária/cirurgia , Dentina/efeitos da radiação , Lasers de Estado Sólido/uso terapêutico , Animais , Bovinos , Intervalos de Confiança , DurezaRESUMO
Piper solmsianum C.DC., which is popularly known as pariparoba, is a shrub that measures 1-3 m in height and it inhabits areas with wet tropical soils. The objective of this study was to analyze the leaf and stem anatomy using light microscopy, scanning electron micrographs, and energy-dispersive X-ray spectroscopy in order to provide information for species identification. The anatomical profile showed the following main microscopic markers: hypostomatic leaf; hypodermis layer on both sides; pearl glands; biconvex midrib shape; five collateral vascular bundles in open arc with the central bundle larger than the others; circular stem shape; collateral vascular bundles arranged in two rings; sinuous sclerenchymatic sheath in the pith; secretory idioblasts; and starch grains in the mesophyll, in the ground parenchyma of the midrib, petiole, and in the stem; and six morphotypes of calcium oxalate crystals (styloids, cuneiform, tabular crystal rosettes, cuneiform crystal rosettes, elongated square dipyramids, as well as very elongated square dipyramids).
Assuntos
Piper/ultraestrutura , Folhas de Planta/ultraestrutura , Caules de Planta/ultraestrutura , Microscopia Eletrônica de Varredura , Piper/química , Folhas de Planta/química , Caules de Planta/química , Espectrometria por Raios XRESUMO
OBJECTIVES: This study evaluated the effects of radiotherapy on the composition of deciduous teeth enamel using micro-energy-dispersive X-ray fluorescence and Fourier transform Raman spectroscopy before and after a pH cycling process. MATERIALS AND METHODS: Ten deciduous molars were sectioned and divided into two groups (n = 10). The radiotherapy group (RT) was irradiated with 54 Gy at 2 Gy/day, 5 days per week for 5 weeks and 2 days, and the normal group (N) was not irradiated. The RT group was evaluated before radiotherapy (RTb), after radiotherapy (RTa), and after radiotherapy and pH cycling (RTc). The normal group was evaluated before (N) and after pH cycling (Nc). The weight percentage (wt%) of calcium (Ca), phosphorus (P), and organic content; the Ca/P ratio; and the integrated area of the Raman bands relative to the organic, carbonate, and phosphate contents were also evaluated. RESULTS: The exclusive use of RT reduced the organic content of the enamel (p = 0.000). The RTc group exhibited a decrease in P wt% (p = 0.016), an increase in the Ca/P ratio (p = 0.000), and a reduction in the integrated area of the phosphate band (p = 0.046). An increase in the Ca/P ratio (p = 0.000) and a reduction in the areas of the carbonate and phosphate bands were found in the RTb/RTc treatments. CONCLUSIONS: RT application at a therapeutic dose reduced the organic content of the deciduous enamel. CLINICAL RELEVANCE: Preventive measures should be included in the patient treatment protocol because of RT-induced chemical changes to the deciduous enamel.