Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.008
Filtrar
1.
JBMR Plus ; 8(8): ziae069, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38957400

RESUMO

This retrospective study investigates the prevalence of atypical femoral fractures (AFFs) among patients admitted with hip and shaft fractures at a tertiary referral center in Beirut, Lebanon. We analyzed electronic medical records and radiology studies of patients aged above 40 admitted with hip and shaft fractures between January 2006 and December 2019. Fractures were confirmed by ICD9 or ICD10 codes. All cases were reviewed by radiologists, and AFFs were identified according to the 2013 revised ASBMR criteria. We identified 1366 hip and shaft fracture patients, of which 14 female patients had 19 AFFs. This represents a prevalence of 1.0% among all hip and shaft fractures patients and 1.7% among all female hip and shaft fracture patients. Bilateral AFFs were found in 5 of the 14 patients. Patients with AFF tended to be younger, with a mean age of 74.3 (±8.6) yr compared to 78.0 (±10.6) for patients with non-AFF fractures. A total of 36% of AFF patients had a prior history of non-traumatic fracture at first admission. A high percentage of patients with AFFs reported intake of proton pump inhibitors (42.9%) and glucocorticoids (21.4%). Bisphosphonate exposure was noted in 64.3% of AFF patients. None of the AFF patients were active smokers or consumed alcohol regularly. BMD assessments were available for 7 AFF patients, indicating osteoporosis in 4 and osteopenia in 3 cases. Hip axis length measurements showed no significant difference between AFF patients (N = 7) and sex and age-matched controls (N = 21). The study underlines the prevalence and characteristics of AFFs in Lebanon, which is consistent with the numbers reported in the literature (0.32%-5%). A larger prospective study that includes hospitals across the nation is needed to gain a more comprehensive view of the prevalence of AFFs in the Lebanese population.

2.
Z Gerontol Geriatr ; 57(4): 321-329, 2024 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-38832983

RESUMO

The numbers of osteoporotic fractures will increase due to the demographic change, which particularly affects the proximal femur, pelvis, proximal humerus, wrist and vertebral column. Surgical treatment is superior to conservative treatment of proximal femoral fractures. Non-dislocated fractures of the wrist can also be treated with a plaster cast but studies suggest that the results in the first 12 months are better after surgical treatment. The situation is similar for fractures of the proximal humerus and non-dislocated fractures in particular can also be treated conservatively. A score and classification were recently developed for making decisions on the treatment of osteoporotic vertebral fractures. Fractures of the anterior and posterior pelvic ring can be treated conservatively with the patient under sufficient analgesia as long as there is no substantial dislocation. The highest priority in geriatric traumatology is fast remobilization.


Assuntos
Tratamento Conservador , Fraturas por Osteoporose , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Moldes Cirúrgicos , Medicina Baseada em Evidências , Fraturas por Osteoporose/terapia , Fraturas por Osteoporose/cirurgia , Fraturas por Osteoporose/diagnóstico , Resultado do Tratamento
3.
Cureus ; 16(5): e59681, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38836146

RESUMO

Managing osteoporotic fractures in older individuals is a difficult task in orthopedic surgery. It requires a careful approach that combines advanced diagnostic methods, customized surgical treatments, and comprehensive rehabilitation strategies. This article presents the results of an analysis carried out at the University Emergency Hospital, Bucharest. The analysis specifically examines the treatment of osteoporotic fractures using different osteosynthesis techniques. Although diagnostic tools like dual-energy X-ray absorptiometry (DXA) and Fracture Risk Assessment Tool (FRAX) have improved, a considerable number of fractures still happen in people who do not have obvious osteoporosis. This emphasizes the importance of using additional diagnostic measures such as high-resolution peripheral quantitative computed tomography (HR-pQCT) and quantitative computed tomography (QCT) to improve the accuracy of predictions. The study demonstrates the intricate nature of surgical decision-making and the significance of adjusting techniques to meet the specific needs of each patient. An instance of osteosynthesis failure resulting from the inappropriate choice of method highlighted the crucial significance of a thorough preoperative assessment. The discussion highlights the importance of early mobilization and rehabilitation in reducing the risks associated with prolonged immobilization and improving patient recovery. This paper strongly supports the use of evidence-based and patient-centered methods in the management of osteoporotic fractures. It emphasizes the importance of utilizing the most recent advancements in diagnostic and surgical technologies. Promising advancements in orthopedic medicine lie in the future, particularly in the integration of interdisciplinary research and personalized medicine. These advancements have the potential to enhance patient outcomes in this population that is at high risk.

4.
Z Gerontol Geriatr ; 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38831113

RESUMO

BACKGROUND: Proximal femoral fractures are severe injuries in geriatric patients. Additionally, geriatric patients are at a high risk of death due to coronavirus disease 2019 (COVID-19). OBJECTIVE: To identify predictors of mortality in geriatric patients with COVID-19 and concurrent proximal femoral fractures. MATERIAL AND METHODS: Patients who underwent surgical treatment for proximal femoral fractures and also tested positive for COVID-19 were included. The age, gender, the American Society of Anesthesiology (ASA) score and the admission from a nursing home were considered as variables. The rate of reoperations, the mortality at 3 months and discharge home were evaluated as outcomes. RESULTS: In this study 46 patients with COVID-19 (female/male 31/15, median age 87.0 years with an interquartile range [IQR] of 9.8 years) met the inclusion criteria. Of these, 32 patients (69.6%) had to be cared for in the intensive care unit and 26 patients (56.5%) had a severe course of COVID-19 with pneumonia. The median length of hospital stay for survivors was 19 (IQR 17.5) days and 4 of the patients (8.7%) required surgical revision. The in-hospital and 3­month mortality were 40.0% (n = 17) and 43.5% (n = 20), respectively. The factors which influenced the in-hospital and 3­month mortality rates were admission from a nursing home, the presence of pneumonia (increased the risk of death) and female gender (protective). CONCLUSION: The occurrence of COVID-19 in patients with proximal femoral fractures has a high mortality. Admission from a nursing home and the presence of pneumonia increased the risk of death, whereas women were at lower risk.

5.
Acta Ortop Bras ; 32(2): e274533, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38933356

RESUMO

Introduction: Proximal femoral nailing for intertrochanteric femur fracture is sometimes a challenging procedure without a traction table, especially if complicated fracture pattern. We aimed to overcome this difficulty with the hook. Materials and Methods: A retrospective study of 60 patients. 28 of the patients reduction was necessitated with a hook (group 1). The other patients did not need to use this technique (group 2, n=32). The collo-diaphyseal angle, lag screw placement, and tip-apex distance were measured using radiographs. Results: There were statistically significant differences between the two groups regarding the Garden Alignment Index, postoperative collo-diaphyseal angle measurements, and tip-apex distance. The Garden Alignment Index was found as 163.92 degrees (dg.) In the frontal plane in group 1, and 154.78 dg in group 2, respectively. In group 1, the tip-apex distance was 16.05 cm, whereas it was 25.32 cm in group 2. The collo-diaphyseal angle was 133.1º in group 1, and 128.65º in group 2. Conclusions: The hook-assisted reduction is beneficial when operating without a traction table; however, it can also be a part of the surgeons' equipment even when operating on a traction table. When difficulties in obtaining an ideal anatomical reduction in displaced intertrochanteric femoral fractures, we suggest using the hook-assisted reduction technique. Level of Evidence III; Case-control Study.


Introdução: Frequentemente, a fixação do fêmur proximal para fratura intertrocantérica do fêmur sem uma mesa de tração é um procedimento desafiador, especialmente se o padrão da fratura for complicado. O objetivo foi superar essa dificuldade utilizando um gancho. Materiais e métodos: Trata-se de um estudo retrospectivo de 60 pacientes. Em 28 desses, a redução foi necessária com um gancho (grupo 1). Os outros pacientes não precisaram usar essa técnica (grupo 2, n=32). O ângulo colo-diafisário, a colocação do parafuso lag e a distância ponta-ápice foram medidos por meio de radiografias. Resultados: Houve diferenças estatisticamente significativas entre os dois grupos com relação ao Índice de Alinhamento de Garden, às medidas do ângulo colo-diafisário pós--operatório e à distância ponta-ápice. O índice de alinhamento de Garden foi de 163,92 graus (dg.) No plano frontal no grupo 1 e 154,78 dg no grupo 2, respectivamente. No grupo 1, a distância ponta-ápice foi de 16,05 cm, enquanto no grupo 2 foi de 25,32 cm. O ângulo colo-diafisário foi de 133,1 graus no grupo 1 e 128,65 graus no grupo 2. Conclusão: A redução assistida por gancho é benéfica quando se opera sem uma mesa de tração; no entanto, ela também pode fazer parte do equipamento do cirurgião mesmo quando se opera em uma mesa de tração. Quando houver dificuldades em obter uma redução anatômica ideal em fraturas femorais intertrocantéricas deslocadas, sugerimos o uso da técnica de redução assistida por gancho. Nível de Evidência III; Estudo de Caso-controle.

6.
Acta Ortop Bras ; 32(2): e278586, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38933352

RESUMO

Objective: Assess complications and risks in staged femoral shaft fracture treatment using external fixation and intramedullary nailing (DCO). Methods: Analysis involved 37 patients with 40 fractures, mostly male (87.5%), average age 32.9 years. Data included ASA score, AO/OTA and Gustilo classifications, Glasgow Coma Score, Injury Severity Score, times to external fixation and conversion, ICU duration, nail type, and reaming status. Complications tracked were mortality, deep infection, and non-union. Results: Predominant fracture type was AO/OTA A (45%), with 40% open (Gustilo A, 93.8%). Average ISS was 21; GCS was 12.7. Median ICU stay was 3 days; average time to conversion was 10.2 days. Retrograde nails were used in 50% of cases, with reaming in 67.5%. Complications included deep infections in 5% and non-union in 2.5%. Conclusion: DCO strategy resulted in low infection and non-union rates, associated with lower GCS and longer ICU stays. Level of Evidence III; Retrospective Cohort Study.


Objetivo: Analisar taxa de complicações e riscos no tratamento estagiado de fraturas diafisárias do fêmur com fixador externo e conversão para haste intramedular (DCO). Métodos: Estudo com 37 pacientes, 35 masculinos, idade média de 32,9 anos, abordando escores ASA, classificação AO/OTA, Gustilo, Glasgow e ISS, tempo até a fixação externa, na UTI e tipo de haste. Complicações como mortalidade, infecção profunda e não união foram registradas. Resultados: Fraturas tipo AO/OTA A foram as mais comuns (45%), com 40% expostas (Gustilo A, 93,8%). ISS médio de 21 e ECG de 12,7. Média de 3 dias na UTI e 10,2 dias até a conversão. Uso de haste retrógrada em 50% dos casos e fresagem em 67,5%. As complicações incluíram infecção profunda em 5% e não união em 2,5%. A não união correlacionou-se com baixo ECG e tempo prolongado na UTI. Conclusão: A estratégia de DCO mostrou-se eficaz com baixas taxas de infecção e não união, associada a baixo ECG e tempo na UTI. Nível de Evidência III; Estudo de Coorte Retrospectivo.

7.
Front Surg ; 11: 1391718, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38803548

RESUMO

Objective: To explore the clinical efficacy of intramedullary reduction techniques for irreducible intertrochanteric femoral fractures with negative medial cortical support. Methods: A retrospective analysis was conducted on 69 patients with irreducible intertrochanteric femoral fractures with negative medial cortical support treated in the Department of Orthopedics at Jiangsu Province Hospital (The First Affiliated Hospital of Nanjing Medical University) from July 2019 to December 2021. Patients were divided into Group A and Group B. Group A (experimental group) consisted of 36 cases with an average age of 76.2 ± 5.9 years, while Group B (control group) comprised 33 cases with an average age of 76.6 ± 6.3 years. Group A received treatment using intramedullary reduction techniques, while Group B received treatment using traditional extramedullary reduction techniques. Both groups achieved anatomic reduction of the medial cortex or slight positive support. Surgical duration, intraoperative fracture reduction time, intraoperative bleeding, intraoperative fluoroscopy time, fracture reduction quality, fracture healing, postoperative neck-shaft angle loss, femoral neck shortening, and hip joint functional recovery score (FRS) were compared between the two groups. Results: All patients were followed up for an average of 13.8 months. Group A showed superior outcomes compared to Group B in surgical duration, intraoperative fracture reduction time, intraoperative bleeding, intraoperative fluoroscopy time, fracture reduction quality, fracture healing, postoperative neck-shaft angle loss, and femoral neck shortening (P < 0.05). Hip joint function assessed by functional recovery score was better in Group A than Group B at 1 and 3 months postoperatively (P < 0.05), with no significant statistical difference at other time points (P > 0.05). Conclusion: For irreducible intertrochanteric femoral fractures with negative medial cortical support, intramedullary reduction techniques used during surgery demonstrated simplicity, significant reduction in surgical duration, decreased intraoperative bleeding, fewer amounts of intraoperative fluoroscopy, improved fracture reduction quality, and reduced surgical complexity. Further clinical research and application are warranted.

8.
Int Orthop ; 2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38761212

RESUMO

PURPOSE: Femoral fractures are common in low and middle-income countries (LMIC), predominantly caused by high-energy trauma. The surgical implant generation network (SIGN®) program offers two different intramedullary nails in LMIC which are designed to be used without image intensifier free of charge for the patients: the SIGN standard nail (SSN®) and the SIGN Fin nail (SFN®). This study aimed to compare the results of the SSN® and the SFN® for the treatment of middle and distal shaft femoral fractures through a retrograde approach. MATERIAL AND METHODS: This was a retrospective, descriptive, and non-experimental study including all consecutive patients who underwent surgical management of middle or distal shaft femoral fracture between January 2017 and May 2022 in an NGO hospital located in Freetown, Sierra Leone. The duration of surgery, type of reduction, complications like screw loosening, implant migration, anterior knee pain and non-union rate at six months of follow up were evaluated. RESULTS: A total of 122 patients were included in the study. Group A: 60 patients were managed with SSN® and Group B: 62 patients with SFN®. The mean operative time was 104 min with SSN® and 78 with SFN® (p < 0.001). Open reduction of the fracture was necessary in ten (16.7%) patients with SSN® and 12 (19.4%) patients treated with SFN® (p = 0.69). Non-union was observed in one (1.7%) patient with SSN® and two (3.2%) patients with SFN® (p = 0.57). CONCLUSIONS: Both options seem equally effective in treating midshaft and distal femoral shaft fractures. The SFN® reduces the surgical time, due to this fact, in polytraumatized patients, patients with bilateral femur fracture or patients with ipsilateral tibia fracture, it can be considered as the best option to be used. There was no statistical difference in the complications presented by the two groups.

10.
Intern Med ; 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38811230

RESUMO

Objectives To assess the association between concomitant use of central nervous system drugs and femoral fracture risk in individuals ≥80 years old in Japan. Methods A case-crossover design was used, defining the case period as 3 days before the fracture diagnosis and the control period as 31-33, 34-36, and 37-39 days prior. The association between the daily intake of central nervous system drugs (Anatomical Therapeutic Chemical codes) and fracture risk was analyzed using conditional logistic regression. Patients Using the Japanese administrative claims database, we examined elderly patients diagnosed with femoral neck fractures between January 1, 2009, and December 31, 2020. Results In 255,875 patients, the concomitant use of central nervous system drugs increased the odds ratios of femoral fracture (3.41[95% confidence interval: 3.27-3.55], 3.69 [3.46-3.91], 3.76 [3.42-4.13], and 4.34 [3.86-4.86] for an intake of >0-1, >1-2, >2-3, and >3 central nervous system drugs, respectively). Conclusions The concomitant use of central nervous system drugs is associated with an increased risk of femoral fractures in individuals ≥80 years old in Japan.

11.
Pflege ; 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38809228

RESUMO

Background: Proximal femoral fracture is common in older people. Beyond a long recovery process and significant permanent functional limitations, older people often experience subsequent Fear of Falling. The phenomenon of Fear of Falling is not fully understood; qualitative research is underrepresented but can provide insights into the experience of those affected. Objectives: We aimed to explore the experiences of Fear of Falling development and to what extent it affects peoples' life after proximal femoral fracture. Methods: We conducted semi-structured, in-depth interviews with nine older people, aged between 61 and 88, who participated in a prospective observational study. Interview data were analysed through inductive content analysis. Results: Six major themes emerged: The development of Fear of Falling; the effect of FoF and hope for recovery; alternating between moments of fear and security; fear of helplessness and of losing independence; strategies for dealing with Fear of Falling and maintaining independence; need of support by health care professionals. Conclusion: To identify and support older people in coping with Fear of Falling (after proximal femoral fracture), strategies for dealing with Fear of Falling across occupational groups and all healthcare settings should be implemented. Nurses have a key role in this process.

12.
J Clin Med ; 13(5)2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38592416

RESUMO

Background: Locked plating for distal femur fractures is widely recommended and used. We systematically reviewed clinical studies assessing the benefits and harms of fracture fixation with locked plates in AO/OTA Type 32 and 33 femur fractures. Methods: A comprehensive literature search of PubMed, Embase, Cinahl, Web of Science, and the Cochrane Database was performed. The studies included randomized and non-randomized clinical trials, observational studies, and case series involving patients with distal femur fractures. Studies of other fracture patterns, studies conducted on children, pathological fractures, cadaveric studies, animal models, and those with non-clinical study designs were excluded. Results: 53 studies with 1788 patients were found to satisfy the inclusion and exclusion criteria. The most common harms were nonunion (14.8%), malunion (13%), fixation failure (5.3%), infection (3.7%), and symptomatic implant (3.1%). Time to full weight-bearing ranged from 5 to 24 weeks, averaging 12.3 weeks. The average duration of follow-up was 18.18 months, ranging from 0.5 to 108 months. Surgical time ranged between 40 and 540 min, with an average of 141 min. The length of stay in days was 12.7, ranging from 1 to 61. The average plate length was ten holes, ranging from 5 to 20 holes. Conclusion: This review aimed to systematically synthesize the available evidence on the risk associated with locked plating osteosynthesis in distal femur fractures. Nonunion is the most common harm and is the primary cause of reoperation. The overall combined risk of a major and critical complication (i.e., requiring reoperation) is approximately 20%.

13.
Cureus ; 16(3): e55702, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38586703

RESUMO

Background Hip fracture is a public health problem globally, and it poses one of the biggest challenges in healthcare due to its associated complications. Objectives The aim of this study is to investigate the quality of life in adult patients in Khartoum State, Sudan, after they have undergone treatment using a gamma nail for proximal femoral fractures. Methodology This cross-sectional descriptive hospital-based study was conducted at Ibrahim Malik, Omdurman, and Bahri Teaching Hospitals over six months, from April to October 2022. The data were collected using an interview questionnaire that covered relevant aspects of the study. The data were analyzed using IBM SPSS Statistics for Windows, V. 26.0 (IBM Corp., Armonk, NY). The study was approved by the Sudan Medical Specialization Board, and ethical clearance was obtained. Results The study included 37 patients. More than half of the patients (59.5%, n=22) were women. The mean age of cases was 66.7 years (standard deviation, ±15.6). The mean time from the time of the fracture to the time of surgery was eight days (±15). Twenty-three (62.2%, n=23) (JRB1) of the patients started weight bearing on the second postoperative day. Regarding the health-related quality of life, 21.6% of the patients had a good health-related quality of life, 67.6% had a fair health-related quality of life, and 10.8% had a poor health-related quality of life. None of the patients reported an excellent quality of life. Based on the Oxford Hip Score, 54.1% of the patients had satisfactory joint function, 29.7% had mild to moderate hip joint function, 13.5% had moderate to severe hip joint function disturbance, and one patient (2.7%) had severe hip joint function problems. Conclusion In this study, the vast majority of the patients who underwent gamma nail surgery for hip fracture had quality of life scores in the fair to good range afterward. The results indicate that nailing is associated with good outcomes regarding quality of life and is an acceptable option for femoral fracture surgeries in Sudan.

14.
J Clin Med ; 13(8)2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38673664

RESUMO

Background: Recently, the T2 alpha nailing system (Stryker, Inc.), which has advanced locking screws that can attach a screw to a rod, has been used worldwide and is expected to improve fracture fixation. We analyzed two cases of supracondylar femoral fractures in older adult patients, in which intraoperative fractures occurred during the insertion of advanced locking screws of the T2 alpha femur retrograde intramedullary nail. Case presentation: A 93-year-old and an 82-year-old woman each underwent T2 alpha femur retrograde nail fixation for supracondylar femur fractures at separate hospitals, and advanced locking screws were used as the proximal transverse locking screws. In both patients, a fracture line was observed at the proximal screw postoperatively, and the fractures were refixed with distal cable wiring and/or femoral distal plates. The patients were subsequently discharged from the same facility with no remarkable pain. Conclusions: When inserting advanced locking screws, it is necessary to enlarge the screw hole in the near-bone cortex with a counterbore drill, which might add torque to the bone cortex that could result in fractures. If the sleeve is distant from the bone, the counterbore drill will not reach the bone, the screw hole will not expand, and the insertion of advanced locking screws will apply a strong torque to the bone cortex and may result in fracture. Moreover, it is important to confirm that the counterbore drill is securely inserted under fluoroscopy and to carefully enlarge the bony foramen manually to prevent fractures during screw insertion.

15.
Cureus ; 16(3): e56374, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38633962

RESUMO

Periprosthetic femoral fractures (PPFF) around total hip arthroplasty (THA) are one of the leading causes of hip revision. High mortality rates are observed after revision in case of PPFF around THA. To modify risk factors, early postoperative mobilization is necessary. Permissive weight bearing (PWB) is designed to optimize clinical recovery in aftercare. This study aimed to perform a scoping review to summarize the current available evidence on postoperative weight bearing in late PPFF around THA and the implementation of PWB in aftercare. A systematic search was performed on the Cochrane Library, Web of Science, Ovid MEDLINE, EMBASE, and CINAHL databases on January 26th, 2023. Articles were screened in two stages by two independent reviewers. Studies describing adult patients with a history of primary THA who were surgically treated for late PPFF and mentioning prescribed postoperative weight-bearing protocols with relevant outcome measures were included. Seven studies were included, reporting data on 22 patients (age range 47-97 years, BMI range 19-32 kg/m2, ASA classification range 2-3). No studies used PWB in aftercare. The non-weight-bearing group showed no complications. The restricted weight-bearing group had one death and one implant failure. The full weight-bearing group experienced one deep infection and one plate removal because of impingement. The main finding was that, after an extensive systematic search, no articles could be included focusing on PWB in patients with a late PPFF after THA. Addressing this gap in the literature is essential to advancing the understanding of postoperative weight-bearing protocols and PWB for late PPFF around THA.

16.
Rev Bras Ortop (Sao Paulo) ; 59(2): e278-e283, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38606142

RESUMO

Objective To evaluate the stability of osteotomies created in the subtrochanteric and trochanteric regions in a pediatric femur model fixed by flexible intramedullary rods. Method Tomographic sections were obtained from a pediatric femur model with two elastic titanium rods and converted to a three-dimensional model. This model created a mesh with tetrahedral elements according to the finite element method. Three virtual models were obtained, and osteotomies were performed in different regions: mediodiaphyseal, subtrochanteric, and trochanteric. A vertical load of 85N was applied to the top of the femoral head, obtaining the displacements, the maximum and minimum main stress, and the equivalent Von Mises stress on the implant. Results With the applied load, displacements were observed at the osteotomy site of 0.04 mm in the diaphyseal group, 0.5 mm in the subtrochanteric group, and 0.06 mm in the trochanteric group. The maximum stress in the diaphyseal, subtrochanteric, and trochanteric groups was 10.4 Pa, 7.52 Pa, and 26.4 Pa, respectively. That is around 40% higher in the trochanteric group in regards to the diaphyseal (control). The minimum stress of the bone was located in the inner cortical of the femur. The equivalent Von Mises stress on the implants occurred at osteotomy, with a maximum value of 27.6 Pa in the trochanteric group. Conclusion In both trochanteric and subtrochanteric osteotomies, fixation stability was often lower than in the diaphyseal model, suggesting that flexible intramedullary nails are not suitable implants for proximal femoral fixations.

17.
Int Orthop ; 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38652245

RESUMO

PURPOSE: Periprosthetic femoral fractures (PPFs) around the hip are challenging complications in orthopaedic surgery, particularly Vancouver type B2 (VTB2) fractures. The surgical management of these fractures is crucial and depends on various factors. Cementless short taper stem with plate osteosynthesis is an alternative surgical technique. This study aims to compare the outcomes of this surgical technique with revision arthroplasty (RA) with long stem in the treatment of VTB2 PPFs. METHODS: This retrospective study was conducted in a single medical institute from February 2010 to May 2019. Patients who had received either total hip arthroplasty or bipolar hemiarthroplasty and subsequently developed a VTB2 PPF were included; patients who sustained intra-operative fractures or received a cemented stem previously were excluded from the analysis. The patients were divided into two groups: group I received RA with cementless long stem, while group II underwent RA with cementless short taper stem with plate osteosynthesis. Demographic data, radiographic and functional outcomes, and complications were analyzed between the two groups. RESULTS: A total of 85 patients diagnosed with VTB2 PPFs were included in the study. There were no significant differences between the two groups in terms of demographic data, including age, gender, mean follow-up times, estimated blood loss, and operative times. The radiographic results showed that there was no significant difference in the incidence of subsidence and implant stability between the two groups. However, group II tended to have less subsidence and periprosthetic osteolysis. Patients in group II had significantly better functional scores (mean Harris hip score: post-operative: 60.2 in group I and 66.7 in group ii; last follow-up: 77.4 in group 1 and 83.2 in group II (both p < 0.05)). There were no significant differences in the overall complication rate, including infection, dislocation, re-fracture, and revision surgery, between the two groups. CONCLUSIONS: Both surgical techniques, cementless long stem and cementless short taper stem with plate osteosynthesis, are effective in the treatment of Vancouver B2 PPFs, with no significant differences in outcomes or complications. However, patients in cementless short taper stem with plate osteosynthesis had better functional scores at both post-operative and the last follow-up.

18.
J Orthop Traumatol ; 25(1): 23, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38653863

RESUMO

BACKGROUND: The exact positioning of the cephalomedullary (CM) nail entry point for managing femoral fractures remains debatable, with significant implications for fracture reduction and postoperative complications. This study aimed to explore the variability in the selection of the entry point among trauma surgeons, hypothesizing potential differences and their association with surgeon experience. METHODS: In this prospective multicenter study, 16 participants, ranging from residents to senior specialists, partook in a simulation wherein they determined the optimal entry point for the implantation of a proximal femoral nail antirotation (PFN-A; DePuy Synthes) in various femora. The inter- and intra-observer variability was calculated, along with comprehensive descriptive statistical analysis, to assess the variability in entry point selection and the impact of surgeon experience. RESULTS: In this study, the mean distance from the selected entry points to the calculated mean entry point was 3.98 mm, with a smaller distance observed among surgeons with more than 500 implantations (ANOVA, p = 0.050). Intra-surgeon variability for identical femora averaged at 5.14 mm, showing no significant differences across various levels of surgical experience or training. Notably, 13.6% of selected entry points would not allow a proper intramedullary positioning of the implant, thereby rendering anatomical repositioning unfeasible. Among these impossible entry points, a significant skew towards anterior placement was observed (70.6% of the impossible entry points), with a smaller fraction being overly lateral (27.5%) or medial (13.7%). On a patient level, the impossibility rate varied widely from 0 to 35% among the different femora examined, with a significantly higher rate seen in younger patients (mean age 55.02 versus 60.32; t-test for independent samples, p = 0.04). CONCLUSIONS: Significant variations exist in surgeons' selection of entry points for proximal femoral nailing, underscoring the task's complexity. Experience does not prevent the choice of unfeasible entry points, emphasizing the inadequacy of a universal approach and pointing towards the necessity for a patient-specific strategy for improved outcomes. TRIAL REGISTRATION NUMBER: DRKS00032465.


Assuntos
Pinos Ortopédicos , Fraturas do Fêmur , Fixação Intramedular de Fraturas , Feminino , Humanos , Masculino , Competência Clínica , Fraturas do Fêmur/cirurgia , Fixação Intramedular de Fraturas/métodos , Fixação Intramedular de Fraturas/instrumentação , Variações Dependentes do Observador , Estudos Prospectivos
19.
Cureus ; 16(1): e53269, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38435949

RESUMO

The increasing prevalence of periprosthetic femoral fractures, specifically in the vicinity of the hip, has emerged as a significant issue in recent times. Consequently, there is a need for a thorough examination to enhance the effectiveness of management and treatment approaches. The findings of this study emphasize a significant disparity in the occurrence and characteristics of these fractures, and the multiple cases have highlighted the efficacy of various treatment strategies, such as open reduction and internal fixation, as well as the utilization of cortical strut allografts. Furthermore, the study has identified potential risk factors that have an impact on the characteristics of fractures, providing valuable insights that could be crucial in the development of preventive strategies. This study provides a thorough examination of periprosthetic femoral fractures, highlighting the importance of a cohesive treatment algorithm to improve the handling of such fractures. Moreover, it promotes the need for a collaborative endeavor in conducting research in this field, cultivating a more profound comprehension that has the potential to drive progress in therapeutic approaches, ultimately enhancing patient results over an extended period of time. It is crucial that forthcoming research endeavors persist in expanding upon these discoveries, striving towards a unified methodology in tackling this substantial clinical obstacle.

20.
Acta Biomater ; 178: 320-329, 2024 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-38479677

RESUMO

Stress-induced corrosion impairs the mechanical integrity of magnesium (Mg) and its alloys as potential orthopedic implants. Although there has been extensive work reporting the effects of stress on Mg corrosion in vitro, the geometric design principles of the Mg-based orthopedic devices still remain largely unknown. In this work, a numerical simulation model mimicking fractured bone fixation and surgical animal models were applied to investigate the effects of the geometric design of Mg screws on the stress distribution and the stress-induced degradation behavior. Finite element (FE) analysis was used for calculation of stress concentrations around the Mg screws, with different thread type, thread pitch, and thread width. Afterward, the Mg screws of the pre-optimization and post-optimization groups exhibiting the highest and lowest stress concentrations, respectively, were implanted in the fractured distal femora and back subcutaneous tissue of rabbits. Encouragingly, there was a significant difference between the pre-optimization and the post-optimization groups in the degradation rate of the stressed screw parts located around the fracture line. Interestingly, there was no significant difference between the two groups in the degradation rate of the non-stressed screw parts. Consistently, the Mg screw post-optimization exhibited a significantly lower degradation rate than that pre-optimization in the back subcutaneous implantation model, which generated stress in the whole screw body. The alteration in geometric design did not affect the corrosion rate of the Mg screws in an immersion test without load applied. Importantly, an accelerated new bone formation with less fibrous encapsulation around the screws was observed in the Mg group post-optimization relative to the Mg group pre-optimization and the poly (lactic acid) group. Geometry optimization may be a promising strategy to reduce stress-induced corrosion in Mg-based orthopedic devices. STATEMENT OF SIGNIFICANCE: Stress concentrations influence corrosion characteristics of magnesium (Mg)-based implants. The geometric design parameters, including thread type, thread pitch, and thread width of the Mg screws, were optimized through finite element analysis to reduce stress concentrations in a fractured model. The Mg screws with triangular thread type, 2.25 mm pitch, and 0.3 mm thread width, exhibiting the lowest maximum von Mises stress, showed a significant decrease in the volume loss relative to the Mg screws pre-optimization. Compared with the Mg screw pre-optimization and the poly(lactic acid) screw, the Mg screw post-optimization favored new bone formation while inhibiting fibrous encapsulation. Collectively, optimization in the geometric design is a promising approach to reduce stress-induced corrosion in Mg-based implants.


Assuntos
Fraturas do Fêmur , Consolidação da Fratura , Animais , Coelhos , Magnésio/farmacologia , Corrosão , Parafusos Ósseos , Fraturas do Fêmur/cirurgia , Análise de Elementos Finitos , Fenômenos Biomecânicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...