Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 122
Filtrar
1.
Physiol Meas ; 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38976988

RESUMO

Even though the electrocardiogram (ECG) has potential to be used as a monitoring or diagnostic tool for fetuses, the use of non-invasive fetal ECG is complicated by relatively high amounts of noise and fetal movement during the measurement. Moreover, machine learning-based solutions to this problem struggle with the lack of clean reference data, which is difficult to obtain. To solve these problems, this work aims to incorporate fetal rotation correction with electrocardiogram denoising into a single unsupervised end-to-end trainable method. This method uses the vectorcardiogram (VCG), a 3-dimensional representation of the ECG, as an input and extends the previously introduced Kalman-LISTA method with a Kalman filter for the estimation of fetal rotation, applying denoising to the rotation-corrected VCG. The resulting method was shown to outperform denoising auto-encoders by more than 3dB while achieving a rotation tracking error of less than 33°. Furthermore, the method was shown to be robust to a difference in signal to noise ratio between electrocardiographic leads and different rotational velocities. Future work should aim at improving the method's generalizability and evaluation of the method's value in research and clinical use. This value might not only derive from the denoised fetal ECG, but from the method's objective measure for fetal rotation as well due to it's potential for early detection of fetal complications.

2.
Asian Pac Isl Nurs J ; 8: e57128, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38924785

RESUMO

BACKGROUND: Interoception encompasses the conscious awareness of homeostasis in the body. Given that fetal movement awareness is a component of interoception in pregnant women, the timing of initial detection of fetal movement may indicate individual differences in interoceptive sensitivity. OBJECTIVE: The aim of this study is to determine whether the association between the gestational week of initial movement awareness and interoception can be a convenient evaluation index for interoception in pregnant women. METHODS: A cross-sectional study was conducted among 32 pregnant women aged 20 years or older at 22-29 weeks of gestation with stable hemodynamics in the Obstetric Outpatient Department. Interoception was assessed using the heartbeat-counting task, with gestational weeks at the first awareness of fetal movement recorded via a questionnaire. Spearman rank correlation was used to compare the gestational weeks at the first awareness of fetal movement and heartbeat-counting task scores. RESULTS: A significant negative correlation was found between the gestational weeks at the first fetal movement awareness and heartbeat-counting task performance among all participants (r=-0.43, P=.01) and among primiparous women (r=-0.53, P=.03) but not among multiparous women. CONCLUSIONS: Individual differences in interoception appear to correlate with the differences observed in the timing of the first awareness of fetal movement.

3.
Neurotoxicol Teratol ; 104: 107368, 2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38906389

RESUMO

BACKGROUND: Buprenorphine-naloxone treatment may confer substantial benefits for the treatment of opioid use disorder (OUD) during pregnancy including lower risk for overdose/death, less diversion potential and reduced use of other substances. Treatment may also result in less severe Neonatal Abstinence Syndrome (NAS), but little is known about the effects of this medication on fetal neurodevelopment. METHODS: The purpose of the current study is to evaluate neurobehaviors among fetuses exposed to buprenorphine-naloxone at four time points over the second and third trimesters of gestation in pregnant women with OUD on buprenorphine-naloxone therapy. Sixty minutes of continuous fetal monitoring via fetal actocardiograph with a single wide array abdominal transducer took place at times of peak and trough buprenorphine-naloxone levels in 24 pregnant women. Data collection, which included measures of fetal heart rate and motor activity, was conducted between 24 and 36 weeks gestation, with the majority (84.6%) monitored at two or more gestational ages. Medication dose and other substance use was monitored throughout the study and infant NAS severity was assessed. RESULTS: Fetal heart rate (FHR), FHR variability, accelerations in FHR, and motor activity were suppressed when buprenorphine-naloxone levels were at pharmacologic peak as compared to trough concentrations at 36 weeks, but not earlier in gestation. Maternal medication dose was unrelated to infant NAS severity. CONCLUSIONS: Conclusions: There were evident subclinical fetal neurophysiological responses at times of peak maternal buprenorphine/naloxone levels in later gestation, similar to those previously described for buprenorphine only. Further studies evaluating the effects of these changes in fetal neurobehaviors on the longer-term infant development are needed.

4.
BMC Pregnancy Childbirth ; 24(1): 365, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38750467

RESUMO

BACKGROUND: Fetal movement monitoring is one of the strategies used to assess the fetus's health. Until now, most studies focused on the decreased fetal movement and neonatal outcome, although this systematic review and meta-analysis is designed to assess the association between increased fetal movements (IFM) with perinatal outcomes. METHOD: The electronic databases including PubMed, Scopus, Web of Science, and EMBASE were systematically searched for studies investigating the perinatal outcome of women with increased fetal movements from inception to July 2023. Following that, a random-effect meta-analysis model was used to obtain the combined diagnostic and predictive parameters including perinatal mortality (still birth and early neonatal mortality), operative delivery, Apgar score, neonatal resuscitation at birth and NICU Admission. RESULTS: After the initial screening, seven studies examining the association between increased third trimester fetal movement and various perinatal outcomes were included. Meta-analysis revealed a significant reduction in the risk of cesarean delivery among patients with IFM compared to controls, suggesting a potential protective effect during childbirth. However, no statistically significant difference was observed in birth weight, small or large for gestational age births, neonatal intensive care unit admission, maternal age, umbilical cord around the neck, gestational diabetes mellitus, and hypertension, indicating that IFM may not be a major predictor of adverse perinatal outcomes or maternal conditions. Notably, IFM was significantly associated with a higher likelihood of labor induction. CONCLUSION: The findings suggest that IFM may have a protective effect against cesarean delivery. Additionally, IFM does not appear to be significantly associated with maternal age, umbilical cord around the neck, gestational diabetes mellitus and hypertension. However, the observed significant association with labor induction warrants further investigation.


Assuntos
Movimento Fetal , Resultado da Gravidez , Terceiro Trimestre da Gravidez , Humanos , Gravidez , Feminino , Recém-Nascido , Resultado da Gravidez/epidemiologia , Cesárea/estatística & dados numéricos , Mortalidade Perinatal , Índice de Apgar
5.
Osteoarthritis Cartilage ; 32(7): 869-880, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38588889

RESUMO

OBJECTIVE: To explore the impact of oligohydramnios on fetal movement and hip development, given its association with developmental dysplasia of the hip (DDH) but unclear mechanisms. METHODS: Chick embryos were divided into four groups based on the severity of oligohydramnios induced by amniotic fluid aspiration (control, 0.2 mL, 0.4 mL, 0.6 mL). Fetal movement was assessed by detection of movement and quantification of residual amniotic fluid volume. Hip joint development was assessed by gross anatomic analysis, micro-computed tomography (micro-CT) for cartilage assessment, and histologic observation at multiple time points. In addition, a subset of embryos from the 0.4 mL aspirated group underwent saline reinfusion and subsequent evaluation. RESULTS: Increasing volumes of aspirated amniotic fluid resulted in worsening of fetal movement restrictions (e.g., 0.4 mL aspirated and control group at E10: frequency difference -7.765 [95% CI: -9.125, -6.404]; amplitude difference -0.343 [95% CI: -0.588, -0.097]). The 0.4 mL aspirated group had significantly smaller hip measurements compared to controls, with reduced acetabular length (-0.418 [95% CI: -0.575, -0.261]) and width (-0.304 [95% CI: -0.491, -0.117]) at day E14.5. Histological analysis revealed a smaller femoral head (1.084 ± 0.264 cm) and shallower acetabulum (0.380 ± 0.106 cm) in the 0.4 mL group. Micro-CT showed cartilage matrix degeneration (13.6% [95% CI: 0.6%, 26.7%], P = 0.043 on E14.5). Saline reinfusion resulted in significant improvements in the femoral head to greater trochanter (0.578 [95% CI: 0.323, 0.833], P = 0.001). CONCLUSIONS: Oligohydramnios can cause DDH by restricting fetal movement and disrupting hip morphogenesis in a time-dependent manner. Timely reversal of oligohydramnios during the fetal period may prevent DDH.


Assuntos
Displasia do Desenvolvimento do Quadril , Modelos Animais de Doenças , Oligo-Hidrâmnio , Microtomografia por Raio-X , Animais , Embrião de Galinha , Oligo-Hidrâmnio/diagnóstico por imagem , Displasia do Desenvolvimento do Quadril/diagnóstico por imagem , Movimento Fetal , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/patologia , Articulação do Quadril/embriologia , Feminino , Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/patologia , Cartilagem Articular/embriologia , Líquido Amniótico , Gravidez
6.
Infant Behav Dev ; 75: 101949, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38663329

RESUMO

Fetal movement is a crucial indicator of fetal well-being. Characteristics of fetal movement vary across gestation, posing challenges for researchers to determine the most suitable assessment of fetal movement for their study. We summarize the current measurement strategies used to assess fetal movement and conduct a comprehensive review of studies utilizing these methods. We critically evaluate various measurement approaches including subjective maternal perception, ultrasound, Doppler ultrasound, wearable technology, magnetocardiograms, and magnetic resonance imaging, highlighting their strengths and weaknesses. We discuss the challenges of accurately capturing fetal movement, which is influenced by factors such as differences in recording times, gestational ages, sample sizes, environmental conditions, subjective perceptions, and characterization across studies. We also highlight the clinical implications of heterogeneity in fetal movement assessment for monitoring fetal behavior, predicting adverse outcomes, and improving maternal attachment to the fetus. Lastly, we propose potential areas of future research to overcome the current gaps and challenges in measuring and characterizing abnormal fetal movement. Our review contributes to the growing body of literature on fetal movement assessment and provides insights into the methodological considerations and potential applications for research.


Assuntos
Movimento Fetal , Humanos , Movimento Fetal/fisiologia , Feminino , Gravidez , Monitorização Fetal/métodos , Ultrassonografia Pré-Natal/métodos , Imageamento por Ressonância Magnética/métodos , Magnetocardiografia/métodos , Feto/fisiologia , Feto/diagnóstico por imagem
7.
Diagnostics (Basel) ; 14(4)2024 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-38396483

RESUMO

A 36-year-old woman, gravida 3, para 1 (previous cesarean section), with one medical abortion, and no history of systemic diseases presented an unremarkable medical history during prenatal visits. The final prenatal ultrasound at 38 weeks of gestation showed a vertex presentation, a weight of 2600 g, a normal amniotic fluid level, and the placenta located on the posterior wall of the uterus. Fetal cardiotocography conducted before delivery reported a reactive heart rate without decelerations. The Doppler wave analysis of the fetal umbilical artery was normal (the ratio of peak-systolic flow velocity to the end-diastolic flow velocity was 2.5) without the absence or reversal of end-diastolic velocity. The total score of the fetal biophysical profile by ultrasound was 8. The night before the scheduled cesarean section, she experienced heightened anxiety and was unable to sleep, noting "crazy" fetal movements throughout the night. During the cesarean section, it was discovered that the umbilical cord was wrapped around the newborn's legs, resembling ankle shackles. The fetal weight was 2740 g, and Apgar scores were 9 at the first minute and 10 at the fifth minute. The motility of the neonatal legs was normal without cyanosis or neurological adverse outcomes.

8.
BMC Pregnancy Childbirth ; 24(1): 56, 2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-38212680

RESUMO

PURPOSE: The current study investigated the direct impact of the COVID-19 lockdown on fetal movements, addressing a critical research gap. While previous research has predominantly examined the effects of lockdown on maternal health and postnatal outcomes, little attention has been paid to the direct consequences on fetal well-being as indicated by their movement profile. METHODS: We conducted analysis of movement profiles in 20 healthy fetuses during the COVID-19 pandemic lockdown (third national UK lockdown period between January and March 2021) and compared them with 20 healthy fetuses from pre-covid pregnancies, all at 32 weeks gestation. We controlled for maternal stress, depression, and anxiety. RESULTS: Pregnant mothers during pre-covid compared with those during the COVID-19 lockdown reported similar levels of stress (p = 0.47), depression (p = 0.15), and anxiety (p = 0.07). Their fetuses, however, differed in their movement profiles with mouth movement frequencies significantly higher during COVID-19 lockdown (COVID-19 lockdown: mean of 5.909) compared to pre-Covid pregnancies (mean of 3.308; p = 0.029). Furthermore, controlling for maternal anxiety a regression analysis indicated that frequency of fetal mouth movements (p = 0.017), upper face movements (p = 0.008), and touch movements (p = 0.031) were all significantly higher in fetuses observed during lockdown compared to fetuses before the Covid period. CONCLUSION: Fetuses show an effect of lockdown independent of maternal anxiety, stress, or depression. These findings contribute to our understanding of fetal development during extraordinary circumstances, raising questions about the potential effects of having to stay indoors during lockdowns.


Assuntos
COVID-19 , Gravidez , Feminino , Humanos , COVID-19/epidemiologia , COVID-19/prevenção & controle , Movimento Fetal , Pandemias , Controle de Doenças Transmissíveis , Desenvolvimento Fetal , Ansiedade/epidemiologia , Depressão/epidemiologia
9.
Int J Gynaecol Obstet ; 164(3): 933-941, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37688370

RESUMO

OBJECTIVE: To characterize obstetric outcomes and the association with umbilical cord (UC) complications among women complaining of reduced fetal movements (RFMs). METHODS: This retrospective cohort compared women with a perception of RFMs within 2 weeks prior to delivery with women who reported no changes in fetal movements in terms of maternal characteristics and neonatal outcomes. A primary outcome of UC complications at delivery was defined. Multivariable regression analysis was performed to identify independent associations with RFMs and UC complications. RESULTS: In all, 46 103 women were included, 2591 (5.6%) of whom reported RFMs and 43 512 (94.4%) in the control group. Compared with controls, the RFM group was more likely to be nulliparous (42.6% vs 32.2%, P < 0.001), smokers (6.4% vs 5.4%, P = 0.029), or obese (body mass index >30) (16.4% vs 11.6%, P < 0.001). They were also more likely to have an anterior placenta (56.2% vs 51.8%, P < 0.001) and poly/oligohydramnios (0.7% vs 0.4%, P = 0.015 and 3.6% vs 2.1%, P < 0.001, respectively). Induction of labor was more common in the RFM group (33.9% vs 19.7%, P < 0.001), as well as meconium (16.8% vs 15.0%, P = 0.026) and vacuum extractions (10.1% vs 8.0%, P < 0.001). Higher rates of stillbirth and the severe composite neonatal outcome were observed in the RFM group (1.5% vs 0.2%, P < 0.001 and 0.6% vs 0.3%, P = 0.010, respectively). The RFM group was characterized by higher rates of triple nuchal cord (P = 0.015), UC around body or neck (32.2% vs 29.6%, P = 0.010), and true knot (2.3% vs 1.4%, P = 0.002). Multivariable logistic regression found RFMs to be independently associated with triple nuchal cord and with a true cord knot. A sub-analysis including only cases of stillbirth (n = 127) revealed even higher rates of UC complications: 7% of all stillbirths presented with a true cord knot (20% true knots were found in stillbirths preceded by RFMs vs 6.1% in stillbirth cases without RFMs). Additionally, 33.8% of all stillbirths presented with nuchal cord (40% preceded by RFMs vs 33.3% without RFMs). CONCLUSIONS: RFMs are associated with increased risk of UC complications observed at delivery, as well as increased risk of stillbirth and neonatal adverse outcomes.


Assuntos
Doenças Fetais , Cordão Nucal , Feminino , Humanos , Recém-Nascido , Gravidez , Movimento Fetal , Cordão Nucal/epidemiologia , Percepção , Estudos Retrospectivos , Natimorto/epidemiologia , Cordão Umbilical
10.
Int J Nurs Stud ; 150: 104643, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38043485

RESUMO

BACKGROUND: Reducing avoidable stillbirth is a global priority. The stillbirth rate in England compares unfavourably to that of some other high-income countries. Poorly-managed episodes of altered fetal movement have been highlighted as a key contributor to avoidable stillbirth, and strategies introduced in England in 2016 to reduce perinatal mortality included recommendations for the management of reduced fetal movement. Despite a downward trend in stillbirth rates across the UK, the effects of policies promoting awareness of fetal movement remain uncertain. OBJECTIVE: To provide in-depth knowledge of how practice and clinical guidance relating to altered fetal movement are perceived, enacted and experienced by midwives and obstetricians, and explore the relationship between recommended fetal movement care and actual fetal movement care. DESIGN: A focused ethnographic approach comprising over 180 h of observation, 15 interviews, and document analysis was used to explore practice at two contrasting UK maternity units. SETTINGS: Antenatal services at two UK maternity units, one in the Midlands and one in the North of England. PARTICIPANTS: Thirty-six midwives, obstetricians and sonographers and 40 pregnant women participated in the study across 52 observed care episodes and relevant unit activity. Twelve midwives and three obstetricians additionally participated in formal semi-structured interviews. METHODS: Fieldnotes, interview transcripts, policy documents, maternity notes and clinical guidelines were analysed using a modified constant comparison method to identify important themes. RESULTS: fetal movement practice was mostly consistent and in line with guideline recommendations. Notwithstanding, most midwives and obstetricians had concerns about this area of care, including challenges in diagnosis, conflicting evidence about activity, heightened maternal anxiety, and high rates of monitoring and intervention in otherwise low-risk pregnancies. To address these issues, midwives spent considerable time reassuring women through information and regular monitoring, and coaching them to perceive fetal movement more accurately. CONCLUSIONS: Practice relating to altered fetal movement might be more uniform than in the past. However, a heightened focus on fetal movement is associated by some midwives and obstetricians with potential harms, including increased anxiety in pregnancy, and high rates of monitoring and intervention in pregnancies where there are no 'objective concerns'. Challenges in diagnosing a significant change in fetal movement with accuracy might mean that interventions and resources are not being directed towards those pregnancies most at risk. More research is needed to determine how healthcare professionals can engage in conversations about fetal movement and stillbirth to support safe outcomes and positive experiences in pregnancy and birth. REGISTRATION: Not registered. TWEETABLE ABSTRACT: Midwives and obstetricians take #reducedfetalmovement seriously but worry this 'unreliable' symptom increases anxiety, monitoring and intervention in many 'low risk' pregnancies.


Assuntos
Tocologia , Feminino , Gravidez , Humanos , Natimorto , Obstetra , Movimento Fetal , Cuidado Pré-Natal/métodos
11.
J Psychosom Obstet Gynaecol ; 45(1): 2291632, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38095324

RESUMO

OBJECTIVE: Strengthening the management of women's self-monitoring during pregnancy is important to reduce fetal death in utero and improve maternal and infant outcomes. However, due to the lack of awareness among pregnant women about the importance of self-monitoring fetal movement, resulting in low behavioral compliance, adverse pregnancy outcomes remain common in China. This study aimed to investigate the relationship between social support and health beliefs and the self-monitoring behavior of fetal movement. In addition, we examined the moderating and mediating effects of health beliefs on fetal movement self-monitoring. METHODS: This cross-sectional study was conducted on 200 postpartum mothers in a tertiary hospital in China. The mothers were asked to complete a socio-demographic questionnaire, the fetal movement self-monitoring behavior questionnaire, the fetal movement self-monitoring health beliefs questionnaire, and the social support rating scale. Data from the questionnaires were analyzed and compared using SPSS 24.0 and PROCESS 3.2. RESULTS: The results of this study showed that the total scores of social supports, health beliefs, fetal movement self-monitoring were 42.98 ± 11.65, 78.605 ± 13.73, and 11.635 ± 2.86, respectively. The study found that when social support and health beliefs were included in the regression equation, both social support and health beliefs showed a positive correlation with fetal movement self-monitoring. Health beliefs partially mediated the effect of social support on fetal movement self-monitoring, accounting for 37.5% of the total effect. CONCLUSION: Social support and health beliefs play a crucial role in influencing the self-monitoring behavior of fetal movements. Therefore, strengthening social support and health beliefs during pregnancy has the potential to improve compliance with fetal movement self-monitoring behaviors for pregnant women.


Assuntos
Movimento Fetal , Gestantes , Feminino , Gravidez , Humanos , Estudos Transversais , Mães , Apoio Social
12.
Placenta ; 145: 100-106, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38118226

RESUMO

INTRODUCTION: SARS-CoV-2 placentitis is associated with placental destruction and insufficiency and can affect perinatal outcome. The aim of the current study was to contribute with increased knowledge regarding placental histology in maternal SARS-CoV-2 infection during the pregnancy, as well as the correlation to the severity of maternal SARS-CoV-2 infection. MATERIAL AND METHODS: This retrospective observational study included 116 women who had a verified SARS-CoV-2 infection during pregnancy and gave birth between April 2020 and February 2022 in the Stockholm region, Sweden. Placental tissue was evaluated regarding several histopathological parameters, amongst them detection of the triad of characteristics of placental SARS-CoV-2 infection: chronic histiocytic intervillositis, fibrin deposition and villous trophoblast necrosis, and immunohistochemistry for ORF-3 protein expression was used for confirmation. Medical records were reviewed for maternal characteristics and neonatal outcome. RESULTS: SARS-CoV-2 placentitis was present in one-fifth of the examined placentas admitted to the institute due to maternal SARS-CoV-2 infection, out of which 86,4 % were delivered by acute caesarian section (ACS), all on fetal indication, and one pregnancy ended in stillbirth. Half of the cases without placentitis were delivered by ACS, out of which 50 % were on fetal indication. There was a clear tendency of a shorter time gap between confirmed maternal SARS-CoV-2 infection and delivery in the placentitis group. DISCUSSION: The presence of SARS-CoV-2 placentitis does not seem to correlate with maternal factors or the severity of infection. It does correlate with development of placental dysfunction of acute/subacute onset and is often manifested as reduced fetal movements.


Assuntos
COVID-19 , Corioamnionite , Complicações Infecciosas na Gravidez , Feminino , Humanos , Recém-Nascido , Gravidez , Transmissão Vertical de Doenças Infecciosas , Placenta , SARS-CoV-2 , Suécia/epidemiologia , Estudos Retrospectivos
13.
Midwifery ; 126: 103796, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37672854

RESUMO

OBJECTIVE: To explore how Swedish Somali migrant women perceive fetal movements, process information about fetal movements, and take actions if decreased fetal activity occurs. DESIGN: A qualitative study based on individual semi-structured interviews. The interviews were analysed using content analysis. SETTING: The study was conducted in Sweden. PARTICIPANTS: Swedish Somali migrant women (n=15) pregnant in their third trimester or recently given birth. FINDINGS: The analysis led to the main category: tailored information about fetal movements enhances the possibility to seek care if the movements decrease. The results are described in the generic categories: explanatory models determine action; and understand and interpret information. KEY CONCLUSIONS: Miscommunication on fetal movements can be a hurdle for Swedish Somali migrant women that may have impact on stillbirth prevention and the quality of care. Improved communication and information tailored to individual needs is essential to achieve equality for women and their newborns. IMPLICATIONS FOR PRACTICE: The midwife can be used as a hub for reassuring that adequate information about fetal movements reaches each individual woman in antenatal care. Individualised information on fetal movements based on the women's own understanding is suggested to increase the possibility that the pregnant woman will seek care if the movements decrease. Somali women's verbal communication can be used to spread accurate information in the Somali community on the importance of seeking care if fetal movements decrease.


Assuntos
Movimento Fetal , Migrantes , Gravidez , Feminino , Recém-Nascido , Humanos , Suécia , Somália , Pesquisa Qualitativa , Comunicação
14.
J Obstet Gynaecol Can ; 45(9): 665-677.e3, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37661122

RESUMO

OBJECTIVE: To summarize the current evidence and to make recommendations for antenatal fetal health surveillance (FHS) to detect perinatal risk factors and potential fetal decompensation in the antenatal period and to allow for timely intervention to prevent perinatal morbidity and/or mortality. TARGET POPULATION: Pregnant individuals with or without maternal, fetal, or pregnancy-associated perinatal risk factors for antenatal fetal decompensation. OPTIONS: To use basic and/or advanced antenatal testing modalities, based on risk factors for potential fetal decompensation. OUTCOMES: Early identification of potential fetal decompensation allows for interventions that may support fetal adaptation to maintain well-being or expedite delivery. BENEFITS, HARMS, AND COSTS: Antenatal FHS in pregnant individuals with identified perinatal risk factors may reduce the chance of adverse outcomes. Given the high false-positive rate, FHS may increase unnecessary interventions, which may result in harm, including parental anxiety, premature or operative birth, and increased use of health care resources. Optimization of surveillance protocols based on evidence-informed practice may improve perinatal outcomes and reduce harm. EVIDENCE: Medline, PubMed, Embase, and the Cochrane Library were searched from inception to January 2022, using medical subject headings (MeSH) and key words related to pregnancy, fetal monitoring, fetal movement, stillbirth, pregnancy complications, and fetal sonography. This document represents an abstraction of the evidence rather than a methodological review. VALIDATION METHODS: The authors rated the quality of evidence and strength of recommendations using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. See online Appendix A (Tables A1 for definitions and A2 for interpretations of strong and weak recommendations). INTENDED AUDIENCE: All health care team members who provide care for or education to obstetrical patients, including maternal fetal medicine specialists, obstetricians, family physicians, midwives, nurses, nurse practitioners, and radiologists. SUMMARY STATEMENTS: RECOMMENDATIONS.


Assuntos
Apêndice , Cuidado Pré-Natal , Feminino , Gravidez , Humanos , Feto , Parto , Monitorização Fetal
15.
Front Med (Lausanne) ; 10: 1160373, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37554507

RESUMO

A wearable device-based fetal movement detection system for pregnant women is proposed to resolve the problems of low accuracy of fetal movement detection by fetal heart monitor, difficulties of fetal movement monitoring by pregnant women in person, and inability to monitor for long periods of time by ultrasonic Doppler imaging device. The overall software design flow of the system is proposed after determining the overall structure of the system based on symmetric sensor. The application circuit of the three-axis acceleration sensor MC3672 and its supporting sensor data collection program are designed, and the application circuit of the main control chip NRF52840 with Cortex-M4 core is analyzed. The function of data collection and algorithm recognition result transfer to a smartphone is realized through the fetal movement recognition and algorithm design and Bluetooth communication design. Finally, the system test scheme is introduced, which involves performing functional tests on four healthy pregnant volunteers and analyzing the results. The experimental results show that the average recognition rate and correct rate of this system to recognize fetal movement is 89.74% when using the real fetal movement actively perceived by pregnant women as the standard, achieving a domestic and wearable design of fetal movement monitoring device for pregnant women that can be used to analyze and predict the fetal health condition.

16.
Sensors (Basel) ; 23(10)2023 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-37430667

RESUMO

Fetal movement (FM) is an important indicator of fetal health. However, the current methods of FM detection are unsuitable for ambulatory or long-term observation. This paper proposes a non-contact method for monitoring FM. We recorded abdominal videos from pregnant women and then detected the maternal abdominal region within each frame. FM signals were acquired by optical flow color-coding, ensemble empirical mode decomposition, energy ratio, and correlation analysis. FM spikes, indicating the occurrence of FMs, were recognized using the differential threshold method. FM parameters including number, interval, duration, and percentage were calculated, and good agreement was found with the manual labeling performed by the professionals, achieving true detection rate, positive predictive value, sensitivity, accuracy, and F1_score of 95.75%, 95.26%, 95.75%, 91.40%, and 95.50%, respectively. The changes in FM parameters with gestational week were consistent with pregnancy progress. In general, this study provides a novel contactless FM monitoring technology for use at home.


Assuntos
Abdome , Movimento Fetal , Gravidez , Feminino , Humanos , Gravação em Vídeo , Gravação de Videoteipe , Monitorização Fetal
17.
Cambios rev. méd ; 22(1): 893, 30 Junio 2023.
Artigo em Espanhol | LILACS | ID: biblio-1451326

RESUMO

Los movimientos fetales son uno de los primeros signos de vitalidad fetal. Durante la gestación, éstos van apareciendo progresivamente. La adecuada adquisición y mantenimiento de los mismos durante la gestación indica un correcto desarrollo neuromuscular, así como de bienestar fetal1. La percepción materna de una Disminución de los Movimientos Fetales (DMF) constituye un motivo de consulta frecuente en los Servicios de Urgencias Obstétricas; toda paciente embarazada debe vigilar los movimientos fetales, mediante un conteo subjetivo de los movimientos del feto, a partir de las 24 semanas de gestación. La DMF constituye el 5 ­ 15% de motivos de consulta en los servicios de Urgencias en el tercer trimestre del embarazo. Hasta un 25% de fetos que presentan una DMF presentarán alguna complicación perinatal (malformaciones, retraso de crecimiento, parto prematuro, hemorragia fetomaterna, y éxitus fetal) incluso en población de bajo riesgo. El manejo inadecuado de la DMF representa un 10-15% de las muertes evitables a término1-3. Es por esto que ninguna paciente que consulte por Disminución de Movimientos Fetales debe ser dada de alta sin asegurarse del adecuado bienestar fetal.


Fetal movements are one of the first signs of fetal vitality. During gestation, they appear progressively. Adequate acquisition and maintenance of fetal movements during gestation indicates correct neuromuscular development, as well as fetal well-being1. Maternal perception of decreased fetal movements (DMP) is a frequent reason for consultation in Obstetric Emergency Departments; every pregnant patient should monitor fetal movements by subjectively counting fetal movements, starting at 24 weeks of gestation. FMD constitutes 5-15% of the reasons for consultation in the emergency department in the third trimester of pregnancy. Up to 25% of fetuses with FMD will present some perinatal complication (malformations, growth retardation, premature delivery, fetomaternal hemorrhage, and fetal death) even in low-risk populations. Inadequate management of FMD accounts for 10-15% of preventable deaths at term1-3. This is why no patient who consults for decreased fetal movements should be discharged without ensuring adequate fetal well-being.


Assuntos
Humanos , Masculino , Feminino , Gravidez , Recém-Nascido , Complicações na Gravidez , Gravidez , Desenvolvimento Fetal , Monitorização Fetal , Movimento Fetal , Obstetrícia , Frequência Cardíaca Fetal , Oximetria , Cardiotocografia , Parto , Equador , Serviços Médicos de Emergência , Morte Fetal
18.
AJOG Glob Rep ; 3(2): 100197, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37064783

RESUMO

BACKGROUND: There is no consensus on the relationship between maternal glucose levels and fetal movements. OBJECTIVE: This study aimed to investigate the correlation between gross fetal movements and maternal glucose levels in the hours around food intake. STUDY DESIGN: This was an observational study with 2 newly developed technologies, which were a glucose monitoring system and a fetal movement acceleration measurement recorder. A total of 15 women with singleton pregnancies were provided with the glucose monitoring system that automatically recorded their glucose levels every 15 minutes. In addition, fetal movements were recorded using the fetal movement acceleration measurement recorder, for 4 hours starting from 1 hour before lunch, once a week beginning at 28 weeks of gestation. For the four 1-hour periods, the ratios of the number of 10-second epochs with fetal movement divided by the total number of epochs (defined as the fetal movement parameter) were compared at the earlier (28-33 weeks of gestation), later (34-39 weeks of gestation), and overall (28-39 weeks of gestation) gestational weeks using analysis of variance analyses. A linear regression analysis was developed between the glucose level and the movement parameter for the earlier, later, and overall gestational weeks. All data were divided into 4 categories: (1) both the glucose level and the fetal movement parameter increased from the previous 15 minutes; (2) the glucose level increased, but the fetal movement parameter did not increase; (3) the glucose level did not increase, but the fetal movement parameter increased; and (4) both glucose level and fetal movement parameter did not increase. The numbers for each category were compared for the earlier, later, and overall gestational weeks using χ2 analyses. RESULTS: There was no significant change in the fetal movement parameter among the four 1-hour periods at the earlier (P=.509), later (P=.884), and overall (P=.816) gestational weeks. There was a positive correlation between the glucose level and the movement parameter at 28 to 33 weeks of gestation (P=.001), but not at 33 to 39 (P=.129) and 28 to 39 (P=.115) weeks of gestation. Compared with fetuses whose mothers did not have increased glucose levels, fetuses whose mothers had increased glucose levels moved more at 28 to 33 weeks of gestation (P=.031), but not at 34 to 39 (P=.398) and 28 to 39 (P=.238) weeks of gestation. CONCLUSION: Having a meal did not change gross fetal movement counting; however, there are positive correlations between maternal glucose level and gross fetal movement at 28 to 33 weeks of gestation, but not at 34 to 39 weeks of gestation, for both glucose values and value changes under natural conditions of the mother and fetus.

19.
Sensors (Basel) ; 23(5)2023 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-36904615

RESUMO

Maternal health includes health during pregnancy and childbirth. Each stage during pregnancy should be a positive experience, ensuring that women and their babies reach their full potential in health and well-being. However, this cannot always be achieved. According to UNFPA (United Nations Population Fund), approximately 800 women die every day from avoidable causes related to pregnancy and childbirth, so it is important to monitor mother and fetal health throughout the pregnancy. Many wearable sensors and devices have been developed to monitor both fetal and the mother's health and physical activities and reduce risk during pregnancy. Some wearables monitor fetal ECG or heart rate and movement, while others focus on the mother's health and physical activities. This study presents a systematic review of these analyses. Twelve scientific articles were reviewed to address three research questions oriented to (1) sensors and method of data acquisition; (2) processing methods of the acquired data; and (3) detection of the activities or movements of the fetus or the mother. Based on these findings, we discuss how sensors can help effectively monitor maternal and fetal health during pregnancy. We have observed that most of the wearable sensors were used in a controlled environment. These sensors need more testing in free-living conditions and to be employed for continuous monitoring before being recommended for mass implementation.


Assuntos
Saúde Materna , Dispositivos Eletrônicos Vestíveis , Gravidez , Feminino , Humanos , Feto/fisiologia , Frequência Cardíaca , Movimento
20.
BJOG ; 130(8): 913-922, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36808681

RESUMO

OBJECTIVE: To investigate the implementation of the Count the Kicks campaign in Iowa to increase maternal awareness of fetal movements and its association with stillbirth rates. DESIGN: Time series analysis. SETTING: Iowa, Illinois, Minnesota and Missouri, USA. SAMPLE: Women giving birth between 2005 and 2018. METHODS: Data regarding campaign activity, including uptake of the app and the distribution of information materials, and population-level data on stillbirth rates and potential confounding risk factors were obtained from publicly available data for 2005-2018. Data were plotted over time and examined in relation to key implementation phases. MAIN OUTCOME MEASURE: Stillbirth. RESULTS: App users were largely centred on Iowa, and increased over time, although the numbers were modest relative to the number of births. Only Iowa demonstrated a reduction in stillbirth (OR 0.96, 95% CI 0.96-1.00 per year; interaction between state and time, p < 0.001); there was a decline from 2008 to 2013 (before the launch of the app), an increase from 2014 to 2016 and a decrease from 2017 to 2018, which coincided with increased app use (interaction between period and time, p = 0.06). With the exception of smoking (which fell from approx. 20% in 2005 to approx. 15% in 2018 in Iowa), all risk factors increased in prevalence, so are unlikely to account for a reduction in stillbirth. CONCLUSIONS: There was a reduction in the stillbirth rate in Iowa, where an information campaign about fetal movements was active; this reduction was not present in neighbouring states. Large-scale intervention studies are needed to determine whether the temporal associations between app use and stillbirth rate are causally related.


Assuntos
Movimento Fetal , Natimorto , Gravidez , Feminino , Humanos , Natimorto/epidemiologia , Fatores de Tempo , Fatores de Risco , Parto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...