Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Histochem Cell Biol ; 157(6): 685-696, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35318489

RESUMO

Electron tomography allows one to obtain 3D reconstructions visualizing a tissue's ultrastructure from a series of 2D projection images. An inherent problem with this imaging technique is that its projection images contain unwanted shifts, which must be corrected for to achieve reliable reconstructions. Commonly, the projection images are aligned with each other by means of fiducial markers prior to the reconstruction procedure. In this work, we propose a joint alignment and reconstruction algorithm that iteratively solves for both the unknown reconstruction and the unintentional shift and does not require any fiducial markers. We evaluate the approach first on synthetic phantom data where the focus is not only on the reconstruction quality but more importantly on the shift correction. Subsequently, we apply the algorithm to healthy C57BL/6J mice and then compare it with non-obese diabetic (NOD) mice, with the aim of visualizing the attack of immune cells on pancreatic beta cells within type 1 diabetic mice at a more profound level through 3D analysis. We empirically demonstrate that the proposed algorithm is able to compute the shift with a remaining error at only the sub-pixel level and yields high-quality reconstructions for the limited-angle inverse problem. By decreasing labour and material costs, the algorithm facilitates further research directed towards investigating the immune system's attacks in pancreata of NOD mice for numerous samples at different stages of type 1 diabetes.


Assuntos
Diabetes Mellitus Experimental , Tomografia com Microscopia Eletrônica , Algoritmos , Animais , Comunicação Celular , Processamento de Imagem Assistida por Computador/métodos , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Endogâmicos NOD
2.
Stereotact Funct Neurosurg ; 99(4): 313-321, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34120107

RESUMO

BACKGROUND: In this study, we describe a technique of optimizing the accuracy of frameless deep brain stimulation (DBS) lead placement through the use of a cannula poised at the entry to predict the location of the fully inserted device. This allows real-time correction of error prior to violation of the deep gray matter. METHODS: We prospectively gathered data on radial error during the operative placements of 40 leads in 28 patients using frameless fiducial-less DBS surgery. Once the Nexframe had been aligned to target, a cannula was inserted through the center channel of the BenGun until it traversed the pial surface and a low-dose O-arm spin was obtained. Using 2 points along the length of the imaged cannula, a trajectory line was projected to target depth. If lead location could be improved, the cannula was inserted through an alternate track in the BenGun down to target depth. After intraoperative microelectrode recording and clinical assessment, another O-arm spin was obtained to compare the location of the inserted lead with the location predicted by the poised cannula. RESULTS: The poised cannula projection and the actual implant had a mean radial discrepancy of 0.75 ± 0.64 mm. The poised cannula projection identified potentially clinically significant errors (avg 2.07 ± 0.73 mm) in 33% of cases, which were reduced to a radial error of 1.33 ± 0.66 mm (p = 0.02) after correction using an alternative BenGun track. The final target to implant error for all 40 leads was 1.20 ± 0.52 mm with only 2.5% of errors being >2.5 mm. CONCLUSION: The poised cannula technique results in a reduction of large errors (>2.5 mm), resulting in a decline in these errors to 2.5% of implants as compared to 17% in our previous publication using the fiducial-less method and 4% using fiducial-based methods of DBS lead placement.


Assuntos
Estimulação Encefálica Profunda , Cirurgia Assistida por Computador , Cânula , Humanos , Imageamento Tridimensional , Tomografia Computadorizada por Raios X
3.
Elife ; 72018 05 29.
Artigo em Inglês | MEDLINE | ID: mdl-29809143

RESUMO

Single particle cryo-electron microscopy (cryoEM) is often performed under the assumption that particles are not adsorbed to the air-water interfaces and in thin, vitreous ice. In this study, we performed fiducial-less tomography on over 50 different cryoEM grid/sample preparations to determine the particle distribution within the ice and the overall geometry of the ice in grid holes. Surprisingly, by studying particles in holes in 3D from over 1000 tomograms, we have determined that the vast majority of particles (approximately 90%) are adsorbed to an air-water interface. The implications of this observation are wide-ranging, with potential ramifications regarding protein denaturation, conformational change, and preferred orientation. We also show that fiducial-less cryo-electron tomography on single particle grids may be used to determine ice thickness, optimal single particle collection areas and strategies, particle heterogeneity, and de novo models for template picking and single particle alignment.


Assuntos
Microscopia Crioeletrônica/instrumentação , Tomografia com Microscopia Eletrônica/instrumentação , Ar/análise , Animais , Apoferritinas/ultraestrutura , Microscopia Crioeletrônica/métodos , DnaB Helicases/ultraestrutura , Tomografia com Microscopia Eletrônica/métodos , Escherichia coli/química , Escherichia coli/enzimologia , Frutose-Bifosfato Aldolase/ultraestrutura , Complexo de Endopeptidases do Proteassoma/ultraestrutura , Coelhos , Desidrogenase do Álcool de Açúcar/ultraestrutura , Propriedades de Superfície , Água/química
4.
J Neurosurg ; 123(3): 721-31, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26140481

RESUMO

OBJECT: Fiducial-based registration (FBR) is used widely for patient registration in image-guided neurosurgery. The authors of this study have developed an automatic fiducial-less registration (FLR) technique to find the patient-to-image transformation by directly registering 3D ultrasound (3DUS) with MR images without incorporating prior information. The purpose of the study was to evaluate the performance of the FLR technique when used prospectively in the operating room and to compare it with conventional FBR. METHODS: In 32 surgical patients who underwent conventional FBR, preoperative T1-weighted MR images (pMR) with attached fiducial markers were acquired prior to surgery. After craniotomy but before dural opening, a set of 3DUS images of the brain volume was acquired. A 2-step registration process was executed immediately after image acquisition: 1) the cortical surfaces from pMR and 3DUS were segmented, and a multistart sum-of-squared-intensity-difference registration was executed to find an initial alignment between down-sampled binary pMR and 3DUS volumes; and 2) the alignment was further refined by a mutual information-based registration between full-resolution grayscale pMR and 3DUS images, and a patient-to-image transformation was subsequently extracted. RESULTS: To assess the accuracy of the FLR technique, the following were quantified: 1) the fiducial distance error (FDE); and 2) the target registration error (TRE) at anterior commissure and posterior commissure locations; these were compared with conventional FBR. The results showed that although the average FDE (6.42 ± 2.05 mm) was higher than the fiducial registration error (FRE) from FBR (3.42 ± 1.37 mm), the overall TRE of FLR (2.51 ± 0.93 mm) was lower than that of FBR (5.48 ± 1.81 mm). The results agreed with the intent of the 2 registration techniques: FBR is designed to minimize the FRE, whereas FLR is designed to optimize feature alignment and hence minimize TRE. The overall computational cost of FLR was approximately 4-5 minutes and minimal user interaction was required. CONCLUSIONS: Because the FLR method directly registers 3DUS with MR by matching internal image features, it proved to be more accurate than FBR in terms of TRE in the 32 patients evaluated in this study. The overall efficiency of FLR in terms of the time and personnel involved is also improved relative to FBR in the operating room, and the method does not require additional image scans immediately prior to surgery. The performance of FLR and these results suggest potential for broad clinical application.


Assuntos
Encéfalo/cirurgia , Imageamento Tridimensional/métodos , Procedimentos Neurocirúrgicos/métodos , Cirurgia Assistida por Computador/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Craniotomia , Feminino , Marcadores Fiduciais , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento , Adulto Jovem
5.
Radiat Oncol J ; 33(2): 89-97, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26157678

RESUMO

PURPOSE: To evaluate the treatment results in early stage non-small cell lung cancer patients who have undergone fiducial-less CyberKnife radiosurgery (CKRS). MATERIALS AND METHODS: From June 2011 to November 2013, 58 patients underwent CKRS at Asan Medical Center for stage I lung cancer. After excluding 14 patients, we retrospectively reviewed the records of the remaining 44 patients. All analyses were performed using SPSS ver. 21. RESULTS: The median age at diagnosis was 75 years. Most patients had inoperable primary lung cancer with a poor pulmonary function test with comorbidity or old age. The clinical stage was IA in 30 patients (68.2%), IB in 14 (31.8%). The mean tumor size was 2.6 cm (range, 1.2 to 4.8 cm), and the tumor was smaller than 2 cm in 12 patients (27.3%). The radiation dose given was 48-60 Gy in 3-4 fractions. In a median follow-up of 23.1 months, local recurrence occurred in three patients (2-year local recurrence-free survival rate, 90.4%) and distant metastasis occurred in 13 patients. All patients tolerated the radiosurgery well, only two patients developing grade 3 dyspnea. The most common complications were radiation-induced fibrosis and pneumonitis. Eight patients died due to cancer progression. CONCLUSION: The results showed that fiducial-less CKRS shows comparable local tumor control and survival rates to those of LINAC-based SABR or CKRS with a fiducial marker. Thus, fiducial-less CKRS using Xsight lung tracking system can be effectively and safely performed for patients with medically inoperable stage I non-small cell lung cancer without any risk of procedure-related complication.

6.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-129488

RESUMO

PURPOSE: To evaluate the treatment results in early stage non-small cell lung cancer patients who have undergone fiducial-less CyberKnife radiosurgery (CKRS). MATERIALS AND METHODS: From June 2011 to November 2013, 58 patients underwent CKRS at Asan Medical Center for stage I lung cancer. After excluding 14 patients, we retrospectively reviewed the records of the remaining 44 patients. All analyses were performed using SPSS ver. 21. RESULTS: The median age at diagnosis was 75 years. Most patients had inoperable primary lung cancer with a poor pulmonary function test with comorbidity or old age. The clinical stage was IA in 30 patients (68.2%), IB in 14 (31.8%). The mean tumor size was 2.6 cm (range, 1.2 to 4.8 cm), and the tumor was smaller than 2 cm in 12 patients (27.3%). The radiation dose given was 48-60 Gy in 3-4 fractions. In a median follow-up of 23.1 months, local recurrence occurred in three patients (2-year local recurrence-free survival rate, 90.4%) and distant metastasis occurred in 13 patients. All patients tolerated the radiosurgery well, only two patients developing grade 3 dyspnea. The most common complications were radiation-induced fibrosis and pneumonitis. Eight patients died due to cancer progression. CONCLUSION: The results showed that fiducial-less CKRS shows comparable local tumor control and survival rates to those of LINAC-based SABR or CKRS with a fiducial marker. Thus, fiducial-less CKRS using Xsight lung tracking system can be effectively and safely performed for patients with medically inoperable stage I non-small cell lung cancer without any risk of procedure-related complication.


Assuntos
Humanos , Carcinoma Pulmonar de Células não Pequenas , Comorbidade , Diagnóstico , Dispneia , Fibrose , Marcadores Fiduciais , Seguimentos , Pulmão , Neoplasias Pulmonares , Metástase Neoplásica , Pneumonia , Radiocirurgia , Recidiva , Testes de Função Respiratória , Estudos Retrospectivos , Taxa de Sobrevida
7.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-129473

RESUMO

PURPOSE: To evaluate the treatment results in early stage non-small cell lung cancer patients who have undergone fiducial-less CyberKnife radiosurgery (CKRS). MATERIALS AND METHODS: From June 2011 to November 2013, 58 patients underwent CKRS at Asan Medical Center for stage I lung cancer. After excluding 14 patients, we retrospectively reviewed the records of the remaining 44 patients. All analyses were performed using SPSS ver. 21. RESULTS: The median age at diagnosis was 75 years. Most patients had inoperable primary lung cancer with a poor pulmonary function test with comorbidity or old age. The clinical stage was IA in 30 patients (68.2%), IB in 14 (31.8%). The mean tumor size was 2.6 cm (range, 1.2 to 4.8 cm), and the tumor was smaller than 2 cm in 12 patients (27.3%). The radiation dose given was 48-60 Gy in 3-4 fractions. In a median follow-up of 23.1 months, local recurrence occurred in three patients (2-year local recurrence-free survival rate, 90.4%) and distant metastasis occurred in 13 patients. All patients tolerated the radiosurgery well, only two patients developing grade 3 dyspnea. The most common complications were radiation-induced fibrosis and pneumonitis. Eight patients died due to cancer progression. CONCLUSION: The results showed that fiducial-less CKRS shows comparable local tumor control and survival rates to those of LINAC-based SABR or CKRS with a fiducial marker. Thus, fiducial-less CKRS using Xsight lung tracking system can be effectively and safely performed for patients with medically inoperable stage I non-small cell lung cancer without any risk of procedure-related complication.


Assuntos
Humanos , Carcinoma Pulmonar de Células não Pequenas , Comorbidade , Diagnóstico , Dispneia , Fibrose , Marcadores Fiduciais , Seguimentos , Pulmão , Neoplasias Pulmonares , Metástase Neoplásica , Pneumonia , Radiocirurgia , Recidiva , Testes de Função Respiratória , Estudos Retrospectivos , Taxa de Sobrevida
SELEÇÃO DE REFERÊNCIAS