Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 401
Filtrar
2.
J Neural Eng ; 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38885679

RESUMO

Study of the foreign body reaction to implanted electrodes in the brain is an important area of research for the future development of neuroprostheses and experimental electrophysiology. After electrode implantation in the brain, microglial activation, reactive astrogliosis, and neuronal cell death create an environment immediately surrounding the electrode that is significantly altered from its homeostatic state. To uncover physiological changes potentially affecting device function and longevity, spatial transcriptomics was implemented to identify changes in gene expression driven by electrode implantation and compare this differential gene expression to traditional metrics of glial reactivity, neuronal loss, and electrophysiological recording quality. For these experiments, rats were chronically implanted with functional Michigan-style microelectrode arrays, from which electrophysiological recordings (multi-unit activity, local field potential) were taken over a six-week time course. Brain tissue cryosections surrounding each electrode were then mounted for spatial transcriptomics processing. The tissue was immunolabeled for neurons and astrocytes, which provided both a spatial reference for spatial transcriptomics and a quantitative measure of glial fibrillary acidic protein (GFAP) and neuronal nuclei (NeuN) immunolabeling surrounding each implant. Results from rat motor cortex within 300µm of the implanted electrodes at 24 hours, 1 week, and 6 weeks post-implantation showed up to 553 significantly differentially expressed (DE) genes between implanted and non-implanted tissue sections. Regression on the significant DE genes identified the 6-7 genes that had the strongest relationship to histological and electrophysiological metrics, revealing potential candidate biomarkers of recording quality and the tissue response to implanted electrodes .

3.
Adv Sci (Weinh) ; : e2308689, 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38863325

RESUMO

Limb neuroprostheses aim to restore motor and sensory functions in amputated or severely nerve-injured patients. These devices use neural interfaces to record and stimulate nerve action potentials, creating a bidirectional connection with the nervous system. Most neural interfaces are based on standard metal microelectrodes. In this work, a new generation of neural interfaces which replaces metals with engineered graphene, called EGNITE, is tested. In vitro and in vivo experiments are conducted to assess EGNITE biocompatibility. In vitro tests show that EGNITE does not impact cell viability. In vivo, no significant functional decrease or harmful effects are observed. Furthermore, the foreign body reaction to the intraneural implant is similar compared to other materials previously used in neural interfaces. Regarding functionality, EGNITE devices are able to stimulate nerve fascicles, during two months of implant, producing selective muscle activation with about three times less current compared to larger microelectrodes of standard materials. CNAP elicited by electrical stimuli and ENG evoked by mechanical stimuli are recorded with high resolution but are more affected by decreased functionality over time. This work constitutes further proof that graphene-derived materials, and specifically EGNITE, is a promising conductive material of neural electrodes for advanced neuroprostheses.

4.
J Biomed Mater Res A ; 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38864257

RESUMO

The foreign body reaction (FBR) to biomaterials results in fibrous encapsulation. Excessive capsule fibrosis (capsular contracture) is a major challenge to the long-term stability of implants. Clinical data suggests that the tissue type in contact with silicone breast implants alters susceptibility to developing capsular contracture; however, the tissue-specific inflammatory and fibrotic characteristics of capsule have not been well characterized at the cellular and molecular level. In this study, 60 breast implant capsule samples are collected from patients and stratified by the adjacent tissue type including subcutaneous tissue, glandular breast tissue, or muscle tissue. Capsule thickness, collagen organization, immune and fibrotic cellular populations, and expression of inflammatory and fibrotic markers is quantified with histological staining, immunohistochemistry, and real-time PCR. The findings suggest there are significant differences in M1-like macrophages, CD4+ T cells, CD26+ fibroblasts, and expression of IL-1ß, IL-6, TGF-ß, and collagen type 1 depending on the tissue type abutting the implant. Subglandular breast implant capsule displays a significant increase in inflammatory and fibrotic markers. These findings suggest that the tissue microenvironment contributes uniquely to the FBR. This data could provide new avenues for research and clinical applications to improve the site-specific biocompatibility and longevity of implantable devices.

5.
J Orthop Case Rep ; 14(6): 152-156, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38910972

RESUMO

Introduction: Metallic foreign body reactions are observed many times, usually in the early periods. However, late presentations are often uncommon. Management of these foreign bodies varies from a military setting to a civilian setting where saving a patient's life is the priority. Case Report: In this case report, we present a 49-year-old soldier with recent onset swelling in the right gluteal region with elevated local temperature and minimal tenderness. The patient suffered a land mine blast injury 10 years ago with multiple injuries to the chest, abdomen, and lower limb. According to military protocols, he was initially managed for life-threatening chest and open abdominal injuries. The right lower limb was non-salvageable and underwent above-knee amputation. A dormant metallic foreign body, which was retained inside the right iliac bone, presented a decade later with a subacute non-pyogenic abscess. Conclusion: The primary goal in military injuries is always to save a patient's life. While acute management remains the same for both military and civilian injuries. In military injuries, deep-seated, inactive foreign bodies are often left behind in order to avoid fresh plane dissection, and to minimize blood loss for early stabilization and save patient lives. Late-onset inflammatory responses are the cause of the delayed presentation of retained foreign bodies.

6.
Aesthetic Plast Surg ; 2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38849553

RESUMO

BACKGROUND: Understanding the impact of breast implants on the histological response in the surrounding fibrous capsule is important; however, consensus is lacking on how to analyze implant capsules histologically. We aimed to develop a standardized histological assessment tool to be used in research potentially improving diagnostic accuracy and treatment strategies for capsular contracture. METHODS: Biopsies of breast implant capsules from 480 patients who had undergone breast augmentation or reconstruction were collected and stained with hematoxylin and eosin. Initially, biopsies from 100 patients were analyzed to select histological parameters demonstrating the highest relevance and reproducibility. Then, biopsies from the remaining 380 patients were used to determine intra- and interobserver agreements of two blinded observers and agreement with a pathologist. Finally, we tested the association between the parameters and capsular contracture. RESULTS: The histological assessment tool included ten parameters assessing the inflammatory, fibrotic, and foreign-body reaction to breast implants, each graded on two-, three-, or four-point scales. Intra- and interobserver agreements were almost perfect (0.83 and 0.80), and agreement with the pathologist was substantial (0.67). Four parameters were significantly correlated with capsular contracture, namely chronic inflammation with lymphocyte infiltration (p < 0.01), thickness of the collagen layer (p < 0.0001), fiber organization (p < 0.01), and calcification (p < 0.001). CONCLUSIONS: This is the first validated histological assessment tool for breast implant capsules. The validated tool not only advances our understanding of capsular contracture but also sets a new standard for histological evaluation in breast implant research and clinical diagnostics. NO LEVEL ASSIGNED: This journal requires that authors assign a level of evidence to each submission to which Evidence-Based Medicine rankings are applicable. This excludes Review Articles, Book Reviews, and manuscripts that concern Basic Science, Animal Studies, Cadaver Studies, and Experimental Studies. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

7.
Aesthetic Plast Surg ; 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38834716

RESUMO

The continuously increasing number of blepharoplasty procedures has resulted in widespread concerns regarding postoperative complications. Embedded threads in blepharoplasty can cause foreign body reactions that can affect surgical outcomes. Foreign body reactions caused by sutures after blepharoplasty can be treated with local injection of 5-fluorouracil in the eyelid.Level of Evidence IV This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

8.
Front Bioeng Biotechnol ; 12: 1367366, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38737540

RESUMO

Introduction: The biocompatibility of an implanted material strongly determines the subsequent host immune response. After insertion into the body, each medical device causes tissue reactions. How intense and long-lasting these are is defined by the material properties. The so-called foreign body reaction is a reaction leading to the inflammation and wound healing process after implantation. The constantly expanding field of implant technology and the growing areas of application make optimization and adaptation of the materials used inevitable. Methods: In this study, modified liquid silicone rubber (LSR) and two of the most commonly used thermoplastic polyurethanes (TPU) were compared in terms of induced inflammatory response in the body. We evaluated the production of inflammatory cytokines, infiltration of inflammatory cells and encapsulation of foreign bodies in a subcutaneous air-pouch model in mice. In this model, the material is applied in a minimally invasive procedure via a cannula and in one piece, which allows material testing without destroying or crushing the material and thus studying an intact implant surface. The study design includes short-term (6 h) and long-term (10 days) analysis of the host response to the implanted materials. Air-pouch-infiltrating cells were determined by flow cytometry after 6 h and 10 days. Inflammation, fibrosis and angiogenesis markers were analyzed in the capsular tissue by qPCR after 10 days. Results: The foreign body reaction was investigated by macroscopic evaluation and scanning electron microscopy (SEM). Increased leukocyte infiltration was observed in the air-pouch after 6 h, but it markedly diminished after 10 days. After 10 days, capsule formations were observed around the materials without visible inflammatory cells. Discussion: For biocompatibility testing materials are often implanted in muscle tissue. These test methods are not sufficiently conclusive, especially for materials that are intended to come into contact with blood. Our study primarily shows that the presented model is a highly adaptable and minimally invasive test system to test the inflammatory potential of and foreign body reaction to candidate materials and offers more precise analysis options by means of flow cytometry.

9.
ACS Biomater Sci Eng ; 10(5): 3006-3016, 2024 05 13.
Artigo em Inglês | MEDLINE | ID: mdl-38640484

RESUMO

Soft implantable devices are crucial to optimizing form and function for many patients. However, periprosthetic capsule fibrosis is one of the major challenges limiting the use of implants. Currently, little is understood about how spatial and temporal factors influence capsule physiology and how the local capsule environment affects the implant structure. In this work, we analyzed breast implant capsule specimens with staining, immunohistochemistry, and real-time polymerase chain reaction to investigate spatiotemporal differences in inflammation and fibrosis. We demonstrated that in comparison to the anterior capsule against the convex surface of breast implants, the posterior capsule against the flat surface of the breast implant displays several features of a dysregulated foreign body reaction including increased capsule thickness, abnormal extracellular remodeling, and infiltration of macrophages. Furthermore, the expression of pro-inflammatory cytokines increased in the posterior capsule across the lifespan of the device, but not in the anterior capsule. We also analyzed the surface oxidation of breast explant samples with XPS analysis. No significant differences in surface oxidation were identified either spatially or temporally. Collectively, our results support spatiotemporal heterogeneity in inflammation and fibrosis within the breast implant capsule. These findings presented here provide a more detailed picture of the complexity of the foreign body reaction surrounding implants destined for human use and could lead to key research avenues and clinical applications to treat periprosthetic fibrosis and improve device longevity.


Assuntos
Implantes de Mama , Fibrose , Reação a Corpo Estranho , Propriedades de Superfície , Implantes de Mama/efeitos adversos , Humanos , Reação a Corpo Estranho/patologia , Reação a Corpo Estranho/metabolismo , Reação a Corpo Estranho/imunologia , Feminino , Silicones/química , Géis de Silicone/efeitos adversos , Citocinas/metabolismo , Inflamação/patologia , Inflamação/metabolismo , Macrófagos/metabolismo , Macrófagos/imunologia
10.
Acta Biomater ; 180: 128-139, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38636789

RESUMO

Titanium as the leading implant material in locked plating is challenged by polymers such as carbon fiber-reinforced polyetheretherketone (CFR-PEEK), which became the focus of interest of researchers and manufacturers in recent years. However, data on human tissue response to these new implant materials are rare. Osteosynthesis plates and peri­implant soft tissue samples of 16 healed proximal humerus fractures were examined (n = 8 CFR-PEEK, n = 8 titanium). Soft tissue was analyzed by immunohistochemistry and µCT. The entrapped foreign bodies were further examined for their material composition by FTIR. To gain insight into their origin and formation mechanism, explanted and new plates were evaluated by SEM, EDX, profilometry and HR-CT. In the peri­implant soft tissue of the CFR-PEEK plates, an inflammatory tissue reaction was detected. Tissues contained foreign bodies, which could be identified as tantalum wires, carbon fiber fragments and PEEK particles. Titanium particles were also found in the peri­implant soft tissue of the titanium plates but showed a less intense surrounding tissue inflammation in immunohistochemistry. The surface of explanted CFR-PEEK plates was rougher and showed exposed and broken carbon fibers as well as protruding and deformed tantalum wires, especially in used screw holes, whereas scratches were identified on the titanium plate surfaces. Particles were present in the peri­implant soft tissue neighboring both implant materials and could be clearly assigned to the plate material. Particles from both plate materials caused detectable tissue inflammation, with more inflammatory cells found in soft tissue over CFR-PEEK plates than over titanium plates. STATEMENT OF SIGNIFICANCE: Osteosynthesis plates are ubiquitously used in various medical specialties for the reconstruction of bone fractures and defects and are therefore indispensable for trauma surgeons, ENT specialists and many others. The leading implant material are metals such as titanium, but recently implants made of polymers such as carbon fiber-reinforced polyetheretherketone (CFR-PEEK) have become increasingly popular. However, little is known about human tissue reaction and particle generation related to these new implant types. To clarify this question, 16 osteosynthesis plates (n = 8 titanium and n = 8 CFR-PEEK) and the overlying soft tissue were analyzed regarding particle occurrence and tissue inflammation. Tissue inflammation is clinically relevant for the development of scar tissue, which is discussed to cause movement restrictions and thus contributes significantly to patient outcome.


Assuntos
Benzofenonas , Placas Ósseas , Fibra de Carbono , Carbono , Inflamação , Cetonas , Polietilenoglicóis , Polímeros , Titânio , Humanos , Cetonas/química , Titânio/química , Titânio/efeitos adversos , Polietilenoglicóis/química , Polímeros/química , Fibra de Carbono/química , Carbono/química , Masculino , Inflamação/patologia , Feminino , Pessoa de Meia-Idade , Idoso , Adulto
11.
Am J Ophthalmol Case Rep ; 34: 102047, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38655572

RESUMO

Purpose: Foreign body reaction to non-absorbable alloplastic orbital implants utilized for bony reconstruction are infrequently documented in the literature. We present the workup and surgical management of a giant cystic mass encapsulating a patient's alloplastic orbital implant, which was ultimately deemed to be a result of foreign body reaction. Observations: A 41-year-old male patient with distant history of a right orbital floor fracture had undergone repair with the placement of a nylon foil implant. The patient presented twenty years later with progressive ipsilateral globe proptosis and was found to have a giant inferior orbital cyst. Surgical exploration and removal of the implant and capsule were performed. Histopathology confirmed a delayed foreign body reaction around the patient's alloplastic implant. Conclusions: Alloplastic implants may result foreign body reaction and cyst encapsulation as a delayed complication.

12.
J Oral Implantol ; 50(3): 260-265, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38660739

RESUMO

To compare histologically the percentage of bone formation 12-20 weeks after ridge augmentation using 2 different techniques. Tooth loss is associated with 3-dimensional bone remodeling and ridge atrophy. Ridge preservation procedures can prevent alveolar bone volume loss. Different techniques and materials are used to preserve the alveolar ridge. Computer-generated randomization software was used to assign 2 ridge preservation techniques for 11 extraction sites. In group I, type I bovine Achilles tendon collagen plugs with bioactive resorbable calcium apatite crystals (CPCAC) were placed, and in group II, cortico-cancellous bone chips (CCBC) mix and an expanded polytetrafluoroethylene (ePTFE) barrier membrane were placed. The histomorphometric studies were performed using a computer-based image analysis system (ImageJ 1.4, National Institute of Health, Bethesda, Md) to calculate the pixel area of bone tissue and the remaining bone graft material. The histomorphometric data were analyzed using a Student t test to compare the measurements between the 2 experimental groups. This parametric statistical test was employed to determine if there were any statistically significant differences in the quantitative histological parameters between the groups. The sockets that received CPCAC showed a lower (31.89%) percentage of native bone surface area compared with the CCBC group (43.87%). However, the difference was not statistically significant (P < .05). In addition, the CPCAC group showed evidence of foreign-body reaction. The CCBC graft covered with an ePTFE barrier may induce more bone formation with minimal inflammation in an extraction socket compared with a collagen plug with calcium apatite crystals. In addition, histological analysis of the CPCAC graft showed evidence of foreign-body reaction, which indicates a negative clinical impact.


Assuntos
Aumento do Rebordo Alveolar , Transplante Ósseo , Transplante Ósseo/métodos , Aumento do Rebordo Alveolar/métodos , Humanos , Politetrafluoretileno , Perda do Osso Alveolar/prevenção & controle , Masculino , Animais , Pessoa de Meia-Idade , Processo Alveolar/patologia , Feminino , Colágeno , Alvéolo Dental/cirurgia , Alvéolo Dental/patologia , Osteogênese/fisiologia
13.
Nanomicro Lett ; 16(1): 186, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38687411

RESUMO

Post-traumatic peritendinous adhesion presents a significant challenge in clinical medicine. This study proposes the use of diamond-like carbon (DLC) deposited on polylactic acid (PLA) membranes as a biophysical mechanism for anti-adhesion barrier to encase ruptured tendons in tendon-injured rats. The results indicate that PLA/DLC composite membrane exhibits more efficient anti-adhesion effect than PLA membrane, with histological score decreasing from 3.12 ± 0.27 to 2.20 ± 0.22 and anti-adhesion effectiveness increasing from 21.61% to 44.72%. Mechanistically, the abundant C=O bond functional groups on the surface of DLC can reduce reactive oxygen species level effectively; thus, the phosphorylation of NF-κB and M1 polarization of macrophages are inhibited. Consequently, excessive inflammatory response augmented by M1 macrophage-originated cytokines including interleukin-6 (IL-6), interleukin-1ß (IL-1ß), and tumor necrosis factor-α (TNF-α) is largely reduced. For biocompatibility evaluation, PLA/DLC membrane is slowly absorbed within tissue and displays prolonged barrier effects compared to traditional PLA membranes. Further studies show the DLC depositing decelerates the release of degradation product lactic acid and its induction of macrophage M2 polarization by interfering esterase and PLA ester bonds, which further delays the fibrosis process. It was found that the PLA/DLC membrane possess an efficient biophysical mechanism for treatment of peritendinous adhesion.

14.
Polymers (Basel) ; 16(6)2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38543422

RESUMO

Poly-L-lactic acid (PLLA) implants have been used for bone fixation for decades. However, upon insertion, they can cause a foreign body reaction (FBR) that may lead to complications. On 15 December 2023, a systematic review was conducted to search for articles on the PubMed, MeSH term, and Scopus databases using the keywords 'PLLA' and 'foreign body reaction'. The articles were reviewed not only for the question of FBR, its severity, and the manifestation of symptoms but also for the type of implant and its location in the body, the species, and the number of individuals included. A total of 71 original articles were identified. Of these, two-thirds reported on in vivo trials, and one-third reported on clinical applications. The overall majority of the reactions were mild in more than half of the investigations. Symptoms of extreme and extensive FBR mainly include osteolysis, ganglion cysts, and swelling. The localization of PLLA implants in bone can often result in osteolysis due to local acidosis. This issue can be mitigated by adding hydroxyapatite. There should be no strong FBR when PLLA is fragmented to 0.5-4 µm by extracorporeal shock wave.

15.
Rev. argent. coloproctología ; 35(1): 40-44, mar. 2024. ilus
Artigo em Espanhol | LILACS | ID: biblio-1551683

RESUMO

En este reporte presentamos tres pacientes en quienes ocurrieron condiciones inflamatorias perianales tardías, luego de la administración de sustancias modeladoras no identificadas en los glúteos. El diagnóstico inicial y supuesto no fue correcto, ya que no se investigó durante la evaluación preliminar el antecedente de la administración de elementos modeladores. Recomendamos que los pacientes con patologías inflamatorias del ano, sobre todo aquellos cuyo curso es extraño, se les pregunte acerca de la administración de agentes modeladores en los glúteos. Esta práctica puede contribuir a la eficacia del diagnóstico de manifestaciones perianales caracterizadas por flogosis, que se presentan de forma inusual. (AU)


In this report we present three patients in which late perianal inflammatory conditions occurred after administration of unidentified modeling agents to the buttocks. The initial diagnosis was not correct because of the administration of modeling agents was not investigated during the initial eval-uation. We recommend inquiring patients with inflammatory pathologies of the anus, especially those whose course is unusual, about the adminis-tration of modeling agents to the buttocks. This approach can contribute to the efficiency of the diagnosis of perianal complaints characterized by inflammation, but rare in its appearance. (AU)


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Doenças do Ânus/cirurgia , Doenças do Ânus/etiologia , Biopolímeros/efeitos adversos , Nádegas/cirurgia , Doenças do Ânus/diagnóstico , Técnicas Cosméticas , Migração de Corpo Estranho , Implantação de Prótese/efeitos adversos
16.
Biomed Tech (Berl) ; 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38462974

RESUMO

OBJECTIVES: One main challenge for textile implants is to limit the foreign body reaction (FBR) and in particular the fibrosis development once the device is implanted. Fibrotic tissue in-growth depends on the fiber size, the pore size, and the organization of the fibrous construction. Basically, non-woven fibrous assemblies present a more favorable interface to biological tissues than do woven structures. However, they are mechanically less strong. In order to combine both strength and appropriate topography properties, the design of a hybrid fibrous construct was considered and discussed in this work. METHODS: Two polyethylene terephthalate (PET) weaves (satin and plain) were assembled with a non-woven PET mat, using an ultrasound welding process. RESULTS: The physical and mechanical properties of the construction as well as its ability to interact with the biological environment were then evaluated. In particular, the wettability of the obtained substrate as well as its ability to interact with mesenchymal stem cells (MSC) at 24 h (adhesion) and 72 h (proliferation) in vitro were studied. CONCLUSIONS: The results show that the non-woven layer helps limiting cell proliferation in the plain weave construction and promotes conversely proliferation in the satin construction.

17.
Acta Biomater ; 177: 91-106, 2024 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-38311198

RESUMO

Designing scaffolds that can regulate the innate immune response and promote vascularized bone regeneration holds promise for bone tissue engineering. Herein, electrospun scaffolds that combined physical and biological cues were fabricated by anchoring reparative M2 macrophage-derived exosomes onto topological pore structured nanofibrous scaffolds. The topological pore structure of the fiber and the immobilization of exosomes increased the nanoscale roughness and hydrophilicity of the fibrous scaffold. In vitro cell experiments showed that exosomes could be internalized by target cells to promote cell migration, tube formation, osteogenic differentiation, and anti-inflammatory macrophage polarization. The activation of fibrosis, angiogenesis, and macrophage was elucidated during the exosome-functionalized fibrous scaffold-mediated foreign body response (FBR) in subcutaneous implantation in mice. The exosome-functionalized nanofibrous scaffolds also enhanced vascularized bone formation in a critical-sized rat cranial bone defect model. Importantly, histological analysis revealed that the biofunctional scaffolds regulated the coupling effect of angiogenesis, osteoclastogenesis, and osteogenesis by stimulating type H vessel formation. This study elaborated on the complex processes within the cell microenvironment niche during fibrous scaffold-mediated FBR and vascularized bone regeneration to guide the design of implants or devices used in orthopedics and maxillofacial surgery. STATEMENT OF SIGNIFICANCE: How to design scaffold materials that can regulate the local immune niche and truly achieve functional vascularized bone regeneration still remain an open question. Here, combining physical and biological cues, we proposed new insight to cell-free and growth factor-free therapy, anchoring reparative M2 macrophage-derived exosomes onto topological pore structured nanofibrous scaffolds. The exosomes functionalized-scaffold system mitigated foreign body response, including excessive fibrosis, tumor-like vascularization, and macrophage activation. Importantly, the biofunctional scaffolds regulated the coupling effect of angiogenesis, osteoclastogenesis, and osteogenesis by stimulating type H vessel formation.


Assuntos
Exossomos , Células-Tronco Mesenquimais , Ratos , Camundongos , Animais , Osteogênese , Alicerces Teciduais/química , Regeneração Óssea , Engenharia Tecidual , Diferenciação Celular , Macrófagos , Fibrose
18.
J Vasc Res ; 61(2): 89-98, 2024.
Artigo em Francês | MEDLINE | ID: mdl-38368869

RESUMO

INTRODUCTION: Vascular prosthetic grafts are widely used in vascular surgery; however, graft infection remains a major concern. Silver-coated vascular grafts have demonstrated anti-infection properties in clinical settings; however, whether the silver irons influence foreign body reaction or neointimal hyperplasia remains unclear. METHODS: Sodium alginate and hyaluronic acid (SA/HA) hydrogel patches loaded with rhodamine, with or without silver, were fabricated. Patches were implanted in the subcutaneous or abdominal cavity and inferior vena cava of rats. Samples were harvested on day 14 and examined via immunohistochemical and immunofluorescence analyses. RESULTS: Silver hydrogel was found to decrease the foreign body reaction; after subcutaneous and abdominal cavity implantation in rats, the capsule was found to be thinner in the silver hydrogel group than in the control hydrogel group. The silver hydrogel group had fewer CD68-positive cells and proliferating cell nuclear antigen and interleukin-33 (IL-33) dual-positive cells than the control hydrogel group. Additionally, the silver hydrogel patch reduced the neointimal thickness after patch venoplasty in rats, and the number of IL-33- and IL-1ß-positive cells was lower than that in the control patch. CONCLUSION: Silver-loaded SA/HA hydrogel patches decreased the foreign body reaction and venous neointimal hyperplasia in rats by the inhibition of IL-33 expression.


Assuntos
Interleucina-33 , Prata , Ratos , Animais , Hiperplasia , Neointima , Reação a Corpo Estranho/etiologia , Reação a Corpo Estranho/prevenção & controle , Hidrogéis
20.
Int J Mol Sci ; 25(4)2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38396755

RESUMO

Brain diseases are oftentimes life-threatening and difficult to treat. The local administration of drug substances using brain implants can increase on-site concentrations and decrease systemic side effects. However, the biocompatibility of potential brain implant materials needs to be evaluated carefully as implants can trigger foreign body reactions, particularly by increasing the microglia and astrocyte reactivity. To date, these tests have been frequently conducted in very simple in vitro models, in particular not respecting the key players in glial cell reactions and the challenges of surgical implantation characterized by the disruption of oxygen and nutrient supply. Thus, we established an in vitro model in which we treated human glial cell lines with reduced oxygen and glucose levels. The model displayed cytokine and reactive oxygen species release from reactive microglia and an increase in a marker of reactive astrocytes, galectin-3. Moreover, the treatment caused changes in the cell survival and triggered the production of hypoxia-inducible factor 1α. In this comprehensive platform, we demonstrated the protective effect of the natural polyphenol resveratrol as a model substance, which might be included in brain implants to ease the undesired glial cell response. Overall, a glial-cell-based in vitro model of the initial challenges of local brain disease treatment may prove useful for investigating new therapy options.


Assuntos
Encefalopatias , Neuroglia , Humanos , Resveratrol/farmacologia , Resveratrol/metabolismo , Neuroglia/metabolismo , Astrócitos/metabolismo , Microglia/metabolismo , Encefalopatias/metabolismo , Oxigênio/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...