Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.833
Filtrar
1.
Sci Rep ; 14(1): 15251, 2024 07 02.
Artigo em Inglês | MEDLINE | ID: mdl-38956182

RESUMO

The early diagnosis and treatment of foreign body aspiration (FBA) can significantly improve the overall prognosis of children. There are significant differences in the epidemiology and clinical characteristics of FBA in different regions. Therefore, we conducted a real-world study in the western region of China with over 4000 patients. The aim of this study was to improve the understanding of FBA in terms of its types, the specific months of its occurrence, and the distribution of primary caregiver characteristics in western China. We collected the clinical and epidemiological data of children who were diagnosed with FBA in our hospital over the past 20 years through a big data centre. We matched the data of healthy children who underwent routine physical examinations at the paediatric health clinic during the same period to analyse the differences in the data of actual guardians. A total of 4227 patients from five provinces were included in this study. Foreign bodies were removed by rigid bronchoscopy in 99.4% (4202/4227) of patients, with a median age of 19 months and a median surgical duration 16 min. January was the most common month of onset for 1725 patients, followed by February, with 1027 patients. The most common types of foreign objects were melon peanuts, seeds and walnuts, accounting for 47.2%, 15.3%, and 10.2%, respectively. In the FBA group, the proportion of grandparents who were primary caregivers was 70.33% (2973/4227), which was significantly greater than the 63.05% in the healthy group (2665/4227) (P < 0.01). FBA most commonly occurs in January and February. More than 60% of FBAs occur between the ages of 1 and 2 years, and the incidence of FBA may be greater in children who are cared for by grandparents. A rigid bronchoscope can be used to remove most aspirated foreign bodies in a median of 16 min.


Assuntos
Broncoscopia , Corpos Estranhos , Humanos , Corpos Estranhos/epidemiologia , China/epidemiologia , Masculino , Feminino , Lactente , Pré-Escolar , Broncoscopia/métodos , Criança , Aspiração Respiratória/epidemiologia , Adolescente
2.
J Visc Surg ; 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38987089

RESUMO

The vast majority of ingested foreign bodies (FB) can pass through the digestive tract without major incidences. In some cases, they accumulate in large amounts in the stomach. They can also perforate the gastrointestinal wall and migrate to extraluminal sites, remaining quiescent for many years. We report a case of a psychiatric patient with more than 100 ingested FB in the stomach.

3.
J Pediatr Urol ; 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38987105

RESUMO

INTRODUCTION: Lost objects and equipment malfunctions during robotic and laparoscopic cases can lead to an increase in operating time and potential risk to the patient. The literature on the management of foreign bodies during pediatric robotic-assisted surgery is limited. The purpose of the video is to review proper instrument handling to prevent loss of an object and to propose our technique for retrieving lost objects through two pediatric case examples. MATERIALS AND METHODS: The first case is a robotic-assisted laparoscopic left pyeloplasty in a 6-week-old male with congenital uteropelvic junction obstruction during which a needle was lost. In the video, we describe our techniques for safe needle passage, proper suturing technique, and recovering a lost needle. The second case is a robotic-assisted right upper pole heminephrectomy in a 14-month-old female with a duplicated renal collecting system and hydroureteronephrosis. We present the management of a rare case during which a harmonic scalpel jaw malfunctioned leading to a lost foreign body. We describe our technique for retrieving the lost fragment. RESULTS: All objects were safely removed, and patients were discharged post-op day one without complication. CONCLUSION: Our video presents two case examples of foreign bodies lost during pediatric robotic surgeries and approaches to manage each of these incidents.

4.
Laryngoscope ; 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38984434

RESUMO

Fish bone foreign bodies (FFBs) are relatively common but can present diagnostic challenges. Herein, we report a case of a 43-year-old female who initially presented to the Emergency Department with fever and throat discomfort after a choking incident, which led to a misdiagnosis of a viral infection after negative chest X-ray findings. Persistent symptoms, including new-onset vocal cord paralysis, prompted further investigation and an otolaryngology - head and neck surgery referral one month later. During the otolaryngology visit eight months after the initial incident, laryngoscopy revealed left true vocal cord paralysis and a subsequent CT scan revealed a 2.3 cm fishbone in the esophagus. Surgical removal involved flexible esophagoscopy and open neck exploration with careful dissection to avoid vascular injury. This case highlights the limitations of initial diagnostic methods, such as X-rays, and the necessity for heightened clinical vigilance and advanced imaging modalities like CT scans for persistent or evolving symptoms, particularly vocal cord paralysis. This case also supports multidisciplinary surgical management in cases of suspected esophageal FFBs involving the internal jugular vein and common carotid artery to prevent serious complications. Laryngoscope, 2024.

5.
Resuscitation ; : 110299, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38964448

RESUMO

This is a commentary on the study conducted by Dunne et al. from Alberta, Canada, which retrospectively analyzed data from patients with foreign body airway obstruction (FBAO) in the region. By linking the region's prehospital data with hospital data, the authors were able to report not only the FBAO relief of each intervention, but also patient survival outcomes and complications associated with the interventions. By analyzing the 709 patient encounters that received BLS interventions from bystanders, paramedics, or both, and adjusting for potential confounders, the study showed that abdominal thrusts and chest compressions were associated with decreased odds of FBAO relief compared to back blows as the first intervention. The commentary summarizes the study findings and discusses the importance of the study in the context of FBAO research, which has been choked for too many years.

7.
Cureus ; 16(6): e61731, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38975392

RESUMO

The use of dentures and dental plates is widespread in the adult population. Accidental ingestion of these foreign objects is not uncommon, with the majority of patients having an uneventful passage of the object through the gastrointestinal tract. Of those patients requiring intervention, endoscopy is the most common, followed by surgical removal. We discuss a case of a patient with prior pelvic surgery and diverticulosis causing severe angulation of the bowel, resulting in non-passage of the foreign object requiring surgical intervention.

8.
Cureus ; 16(6): e61811, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38975410

RESUMO

In the pediatric population, foreign bodies within the urinary bladder are uncommon, typically resulting from urethral insertion out of curiosity. Other etiologies include sexual assault, iatrogenic factors, or migration from adjacent sites. Symptoms such as urinary retention, dysuria, increased frequency, decreased volume, nocturia, hematuria, painful erections, and pelvic pain are common. Radiographic imaging in the form of pelvic X-rays, ultrasound and CT scans often aids in diagnosis and making an action plan. Management depends on the object type, size, location and available expertise, often starting with a transurethral approach and resorting to open surgery if necessary. This case report describes a 13-year-old female presenting with severe dysuria and visible hematuria. Initially reporting the accidental insertion of a scarf pin into her vagina, she later admitted to intentionally inserting it. A pelvic radiograph revealed a needle-like object in the pelvis but its location and position were more convincing of its presence in the urinary bladder. A diagnostic cystoscopy was performed which confirmed a scarf pin in the urinary bladder, embedded in its wall. The pin was successfully removed transurethrally using endoscopic forceps.

9.
Cureus ; 16(6): e62100, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38989322

RESUMO

BACKGROUND: Instances of choking continue to pose a concern for the health and safety of children. This study aims to assess parents' understanding, awareness, and perspectives on child choking. METHODS: A cross-sectional study was conducted in the Al-Baha region of Saudi Arabia from September 13, 2023, to October 3, 2023. Data collection was done via an electronically validated questionnaire among parents aged 18 years and above, covering knowledge, attitudes, and practices. Statistical analysis was performed using the Mann-Whitney U test, the Kruskal-Wallis test, the Shapiro-Wilk test, and the Kolmogorov-Smirnov test. Any result below 0.05 (p < 0.05) was considered significant. RESULTS: Out of 819 participants, 705 individuals were included in the analysis. The results indicated that there was a good level of knowledge (55%) regarding handling child choking situations. Interestingly, females demonstrated higher levels of awareness compared to males (79.4% versus 20.6%). Attitudes toward managing child choking incidents were rated as overall moderate, with 66.5% showing poor practices, such as being hesitant to seek medical assistance if symptoms improved. A majority of choking cases occurred at home (85%), underscoring the importance of enhancing intervention strategies through increased knowledge dissemination. Notably, the internet and social media platforms (71.8%) emerged as primary sources of information on dealing with child choking incidents. There was significant interest in cardiopulmonary resuscitation (CPR) classes (69.2%), although many people found it hard to make time for them (45%). CONCLUSIONS: Parents in the Al-Baha area seem to have a good understanding but some concerning attitudes when it comes to child choking situations. It is important to spread awareness, correct misconceptions, and encourage CPR training.

10.
Int J Surg Case Rep ; 121: 110018, 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38991366

RESUMO

INTRODUCTION AND IMPORTANCE: Bronchial foreign body aspiration is a life-threatening emergency. Largely, the published literature focuses on the removal of foreign bodies by bronchoscopy, while the surgical removal of endobronchial foreign bodies is rarely reported on. Thus, we presented a case of a bronchial foreign body that was successfully removed by a video-assisted thoracoscopic surgical (VATS) bronchotomy, after multiple failed bronchoscopic attempts. CASE PRESENTATION: A 77-year-old male patient presented with a 2-month duration of a persistent cough and low-grade fever after undergoing dental treatment. Bronchoscopy revealed a dental crown surrounded by granulation tissue in the right basal bronchus. The patient was referred to our department for open surgery after undergoing multiple unsuccessful extractions. The bronchial foreign body was removed by a VATS bronchotomy. The postoperative course was uneventful, and the patient was discharged 2 days postoperatively without any complications. CLINICAL DISCUSSION: Most aspirated tracheobronchial foreign bodies can be removed through bronchoscopy; nonetheless, certain aspirated foreign bodies may require surgical intervention. Furthermore, the indications for bronchotomies encompass the failure to remove the foreign body despite repeated attempts, due to immobility, with or without distal bronchial placement. Thoracoscopy is beneficial in providing superior visualization, with an increased likelihood of post-bronchotomy recovery. CONCLUSION: VATS bronchotomy is a safe and effective alternative for the removal of bronchial foreign bodies without sacrificing the functioning of the lung parenchyma.

11.
World J Clin Pediatr ; 13(2): 91275, 2024 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-38947998

RESUMO

BACKGROUND: The technological evolution of bronchoscopy has led to the widespread adoption of flexible techniques and their use for both diagnostic and therapeutic purposes. Currently, there is an active debate regarding the comparative efficacy and safety of rigid vs flexible bronchoscopy in the treatment of foreign body aspiration. AIM: To evaluate our experience with tracheobronchial foreign body extraction using flexible bronchoscopy and provide a literature overview. METHODS: This was a single-centre retrospective study. Twenty-four patients were enrolled between January 2017 and January 2023. Medical records of patients aged below 18 years who were admitted to authors' affiliated institution with a suspected diagnosis of foreign body aspiration were collected from hospital's database to Microsoft Excel 2019. Data were analysed using MedCalc Statistical Software. RESULTS: Patient ages varied from 9 months to 11 years. The median age was 23.5 months, 95% confidence interval (CI) 19.49-44.77. We observed age clustering in children with foreign body aspiration at our institution with three age subgroups: (1) 0-25 months; (2) 40-60 months; and (3) 120-140 months. We expectancy of an organic tracheobronchial foreign body was significantly higher in 0-25 months subgroup than that in older ones when subgroups 40-60 and 120-140 months were combined together (odds ratio = 10.0, 95%CI: 1.44-29.26, P = 0.0197). Successful foreign body extraction was performed in all cases. Conversion to a rigid bronchoscope was not required in any of the cases. No major complications (massive bleeding, tracheobronchial tree perforation, or asphyxia) were observed. CONCLUSION: Flexible bronchoscopy is an effective and safe method for tracheobronchial foreign body extraction in children.

12.
Artigo em Inglês | MEDLINE | ID: mdl-38951225

RESUMO

INTRODUCTION: Magnetic intraocular foreign bodies can be removed with magnetized disposable forceps. Aim of this study is to compare the forceps magnetizability of different size, form and manufacturer. METHODS: The forceps were magnetized using an established procedure. The inducible magnetic flux density was measured at the tip of the forceps. The mass that can be lifted with the magnetized forceps was then tested using steel balls in BSS solution. The weight of the metal parts of the forceps was measured. RESULTS: The magnetic flux density that could be induced, the weight of the steel balls that could be lifted and the mass of stainless steel used in the forceps were as follows: Alcon end-grasping 23G: 7.12 mT, 87.43 mg, 1191 mg; Alcon end-grasping 25G: 6.43 mT, 87.43 mg, 1189 mg; Alcon serrated: 4.39 mT, 63.78 mg, 1284 mg; Alcon serrated 23G: 3.62 mT, 13.74 mg, 1200 mg; Alcon serrated 25G: 2.4 mT, 13.74 mg, 1195 mg; DORC end-grasping 23G: 5.52 mT, 32.54 mg, 153 mg; Synergetics end-grasping 23G: 4.35 mT, 16.37 mg, 193 mg; Vitreq BV end-grasping 23G: 2.65 mT, none, 88 mg. DISCUSSION: The magnetizability of a disposable microforceps seems to depend on the mass of steel at the tip of the forceps. The structure of the iron lattice could have an even greater influence. Not every disposable forceps can be sufficiently magnetized for this technique.

13.
Int J Surg Case Rep ; 121: 110002, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38968849

RESUMO

INTRODUCTION: Textiloma is a rare surgical complication. The location in the renal compartment is exceptional. The diagnosis can be difficult due to its rarity and the absence of clinical signs. The best treatment remains preventive by carefully counting the compresses and the operating fields at the beginning and end of the procedure. PRESENTATION OF CASE: We present a case report of a 71-year-old female patient with a high blood pressure under treatment. In this history, we noted a right nephrectomy by a lombotomy 6 years ago indicated for a mute kidney on a pyelo-ureteral junction syndrome and a drainage of a suppuration of this renal compartment a year after surgery. The patient was diagnosed with purulent discharge through the lombotomy site associated with lower back pain that had been present for 4 years. The patient then underwent an uro-CT scan which showed an oval formation of the right renal compartment suggestive of a textiloma. An exploratory right lombotomy was performed. And then the wetraction of the compresses followed by washing and closing had been done. The postoperative course was simple. DISCUSSION: The location in the renal compartment is exceptional. These may include compresses, surgical gauzes, sponges, cotton pads, etc. The inflammation caused by this foreign body will be responsible for an abscess in the event of infection. An evolution towards chronicity follows as long as the foreign body persists. Diagnosis and reoperation are often made during the same hospitalization period. Early imaging will help to make early diagnosis avoiding diagnostic wandering. The diagnosis was made late in our observation. However, the diagnosis can be difficult due to its rarity and the absence of clinical signs. CONCLUSION: Textiloma is a rare surgical complication. Renal localization, although rare, is "exceptional" of consequence. The best treatment remains preventive by carefully counting the compresses and the operating fields at the beginning and end of the procedure.

14.
Acta Biomater ; 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38972625

RESUMO

Polymeric elastomers are widely utilized in implantable biomedical devices. Nevertheless, the implantation of these elastomers can provoke a robust foreign body response (FBR), leading to the rejection of foreign implants and consequently reducing their effectiveness in vivo. Building effective anti-FBR coatings on those implants remains challenging. Herein, we introduce a coating-free elastomer with superior immunocompatibility. A super-hydrophilic anti-fouling zwitterionic layer can be generated in situ on the surface of the elastomer through a simple chemical trigger. This elastomer can repel the adsorption of proteins, as well as the adhesion of cells, platelets, and diverse microbes. The elastomer elicited negligible inflammatory responses after subcutaneous implantation in rodents for 2 weeks. No apparent fibrotic capsule formation was observed surrounding the elastomer after 6 months in rodents. Continuous subcutaneous insulin infusion (CSII) catheters constructed from the elastomer demonstrated prolonged longevity and performance compared to commercial catheters, indicating its great potential for enhancing and extending the performance of various implantable biomedical devices by effectively attenuating local immune responses. STATEMENT OF SIGNIFICANCE: The foreign body response remains a significant challenge for implants. Complicated coating procedures are usually needed to construct anti-fibrotic coatings on implantable elastomers. Herein, a coating-free elastomer with superior immunocompatibility was achieved using a zwitterionic monomer derivative. A pure zwitterionic layer can be generated on the elastomer surface through a simple chemical trigger. This elastomer significantly reduces protein adsorption, cell and bacterial adhesion, and platelet activation, leading to minimal fibrotic capsule formation even after six months of subcutaneous implantation in rodents. CSII catheters constructed from the PQCBE-H elastomer demonstrated prolonged longevity and performance compared to commercial catheters, highlighting the significant potential of PQCBE-H elastomers for enhancing and extending the performance of various implantable biomedical devices.

15.
Int J Gen Med ; 17: 2757-2766, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38895049

RESUMO

Purpose: To explore the computed tomography (CT) features of bronchopneumonia caused by pepper aspiration to improve the diagnosis. Materials and Methods: 28 adult patients diagnosed with obstructive pneumonia caused by pepper aspiration from January 2016 to September 2022 were enrolled. The CT characteristics of bronchial changes and pulmonary lesions caused by pepper were analyzed and summarized. Results: Among 28 patients, the most common symptom was cough (26, 92.9%), followed by expectoration (23, 82.1%). Bronchoscopy revealed that peppers were mainly found in the bronchus of the right lower lobe (n = 18, 64.3%), followed by the bronchus of the left lower lobe (n = 5, 17.9%). In combination with bronchoscopy results, the pepper in the bronchus manifested as circular or V/U-shaped high-density, localized soft tissue, and flocculent opacification in 8 (28.6%), 16 (57.1%), and 3 (10.7%) cases on CT images, respectively. The bronchial wall around the pepper was thickened with localized occlusion (n = 19, 67.9%) and stenosis (n = 9, 32.1%). Regarding adjacent bronchi without peppers, extensive wall thickening with stenosis and/or occlusion was found in 23 (82.1%) cases. Distal pulmonary lesions frequently involved two or three segments (21, 75.0%) and mainly presented as patchy consolidation or atelectasis (24, 85.7%). Conclusion: In combination to a history of eating peppers and clinical symptoms, bronchopneumonia caused by pepper should be highly suspected if U/V-shaped and annular high-density or localized soft tissue density is detected in the bronchi of the lower lobes, accompanied by extensive bronchial wall thickening, stenosis, or occlusion, and consolidation or atelectasis in multiple distal lung segments.

16.
J Neural Eng ; 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38885679

RESUMO

Study of the foreign body reaction to implanted electrodes in the brain is an important area of research for the future development of neuroprostheses and experimental electrophysiology. After electrode implantation in the brain, microglial activation, reactive astrogliosis, and neuronal cell death create an environment immediately surrounding the electrode that is significantly altered from its homeostatic state. To uncover physiological changes potentially affecting device function and longevity, spatial transcriptomics was implemented to identify changes in gene expression driven by electrode implantation and compare this differential gene expression to traditional metrics of glial reactivity, neuronal loss, and electrophysiological recording quality. For these experiments, rats were chronically implanted with functional Michigan-style microelectrode arrays, from which electrophysiological recordings (multi-unit activity, local field potential) were taken over a six-week time course. Brain tissue cryosections surrounding each electrode were then mounted for spatial transcriptomics processing. The tissue was immunolabeled for neurons and astrocytes, which provided both a spatial reference for spatial transcriptomics and a quantitative measure of glial fibrillary acidic protein (GFAP) and neuronal nuclei (NeuN) immunolabeling surrounding each implant. Results from rat motor cortex within 300µm of the implanted electrodes at 24 hours, 1 week, and 6 weeks post-implantation showed up to 553 significantly differentially expressed (DE) genes between implanted and non-implanted tissue sections. Regression on the significant DE genes identified the 6-7 genes that had the strongest relationship to histological and electrophysiological metrics, revealing potential candidate biomarkers of recording quality and the tissue response to implanted electrodes .

17.
J Med Case Rep ; 18(1): 293, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38886746

RESUMO

BACKGROUND: Gossypiboma, a retained surgical sponge with a foreign body reaction, is an unusual but serious complication seen in open abdominal surgeries. It is exceptionally rare following head and neck surgeries. Here, we present a case of Gossypiboma of the upper airway following tracheostomy. CASE PRESENTATION: A 32-year-old male presented with stridor and difficulty breathing one-month post-tracheostomy after a severe head injury following a road traffic accident. A neck radiograph was unremarkable, and a computed tomography (CT) scan of the neck showed a well-defined homogenous curvilinear membrane extending from the hypopharynx to the upper trachea. Bronchoscopic evaluation of the larynx and upper trachea revealed a retained surgical sponge, which was retrieved. The patient's breathing improved drastically post intervention. CONCLUSION: Gossypiboma may go undetected in radiographs and may also present atypically as a homogenous membrane on a CT scan of the neck. Though rare, retained surgical items can have profound medicolegal and professional consequences on physicians. Hence, a strong clinical suspicion and vigilance for gossypiboma is necessary for patients presenting with respiratory distress post-tracheostomy.


Assuntos
Corpos Estranhos , Laringe , Sons Respiratórios , Tampões de Gaze Cirúrgicos , Tomografia Computadorizada por Raios X , Traqueostomia , Humanos , Masculino , Sons Respiratórios/etiologia , Adulto , Tampões de Gaze Cirúrgicos/efeitos adversos , Corpos Estranhos/complicações , Corpos Estranhos/diagnóstico por imagem , Corpos Estranhos/cirurgia , Laringe/diagnóstico por imagem , Laringe/lesões , Traqueostomia/efeitos adversos , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Acidentes de Trânsito
19.
Am J Emerg Med ; 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38845289

RESUMO

We report a case of a patient with dermal piercings of the hand that were used to anchor body jewelry. The piercings had become infected and were causing the patient pain. She requested that they be removed in the emergency department (ED). Both piercings were successfully removed by anesthetizing the area and creating a small linear incision at the base of the stud before gentle removal of the dermal anchor with a hemostat. This report outlines a simple way to remove the piercings while minimizing tissue damage.

20.
Cureus ; 16(5): e59632, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38832168

RESUMO

In clinical practice, the typical approach to ingested foreign bodies in stable patients involves expectant management, as most materials pass through the gastrointestinal (GI) tract without adverse effects. However, foreign bodies that travel through the appendix's lumen can cause acute appendicitis due to their inability to exit the colon. Rarer causes of appendicitis include parasitic infiltration by Ascaris lumbricoides. The wandering behavior of Ascaris lumbricoides within the GI tract can lead to various surgical complications in the abdomen. Occasionally, these parasites can migrate to the vermiform appendix, where they may either induce pathological changes or remain asymptomatic. We report an unusual case of an eight-year-old Pakistani female patient who presented to the emergency room with pain in the right iliac fossa, associated with anorexia and nausea, for one day. On examination, the patient was found to be vitally stable, with right iliac fossa tenderness noted on palpation. Additionally, the patient exhibited positive pointing, rebound, Rovsing, and psoas signs. Her medical history revealed that she had ingested a metallic needle seven months ago. Blood tests were undertaken, and an abdominal X-ray confirmed the existence of a radiopaque metallic object in the right lower quadrant of the abdomen. The patient underwent an open appendicectomy for acute appendicitis and was discovered to have a metallic needle lodged in the vermiform appendix. Concurrently, she also had ascariasis, as she vomited a 23-cm-long Ascaris lumbricoides worm. It is important to consider both mechanical and parasitic etiologies in diagnosing acute appendicitis; detailed evaluation and management strategies are necessary to address these unique etiologies effectively.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...