Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
J Thorac Dis ; 16(4): 2623-2636, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38738252

RESUMO

Background and Objective: Blood flow assessment is an emerging technique that allows for assessment of hemodynamics in the heart and blood vessels. Recent advances in cardiovascular imaging technologies have made it possible for this technique to be more accessible to clinicians and researchers. Blood flow assessment typically refers to two techniques: measurement-based flow visualization using echocardiography or four-dimensional flow magnetic resonance imaging (4D flow MRI), and computer-based flow simulation based on computational fluid dynamics modeling. Using these methods, blood flow patterns can be visualized and quantitative measurements of mechanical stress on the walls of the ventricles and blood vessels, most notably the aorta, can be made. Thus, blood flow assessment has been enhancing the understanding of cardiac and aortic diseases; however, its introduction to clinical practice has been negligible yet. In this article, we aim to discuss the clinical applications and future directions of blood flow assessment in aortic surgery. We then provide our unique perspective on the technique's translational impact on the surgical management of aortic disease. Methods: Articles from the PubMed database and Google Scholar regarding blood flow assessment in aortic surgery were reviewed. For the initial search, articles published between 2013 and 2023 were prioritized, including original articles, clinical trials, case reports, and reviews. Following the initial search, additional articles were considered based on manual searches of the references from the retrieved literature. Key Content and Findings: In aortic root pathology and ascending aortic aneurysms, blood flow assessment can elucidate postoperative hemodynamic changes after surgical reconfiguration of the aortic valve complex or ascending aorta. In cases of aortic dissection, analysis of blood flow can predict future aortic dilatation. For complicated congenital aortic anomalies, surgeons may use preoperative imaging to perform "virtual surgery", in which blood flow assessment can predict postoperative hemodynamics for different surgical reconstructions and assist in procedural planning even before entering the operating room. Conclusions: Blood flow assessment and computational modeling can evaluate hemodynamics and flow patterns by visualizing blood flow and calculating biomechanical forces in patients with aortic disease. We anticipate that blood flow assessment will become an essential tool in the treatment planning and understanding of the progression of aortic disease.

2.
Quant Imaging Med Surg ; 14(4): 2800-2815, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38617138

RESUMO

Background: Thoracoabdominal aortic aneurysms (TAAAs) are rare but complicated aortic pathologies that can result in high morbidity and mortality. The whole-aorta hemodynamic characteristics of TAAA survivors remains unknown. This study sought to obtain a comprehensive view of flow hemodynamics of the whole aorta in patients with TAAA using four-dimensional flow (4D flow) magnetic resonance imaging (MRI). Methods: This study included patients who had experienced TAAA or abdominal aortic aneurysm (AAA) and age- and sex-matched volunteers who had attended China Hospital from December 2021 to December 2022 in West. Patients with unstable ruptured aneurysm or other cardiovascular diseases were excluded. 4D-flow MRI that covered the whole aorta was acquired. Both planar parameters [(regurgitation fraction (RF), peak systolic velocity (Vmax), overall wall shear stress (WSS)] and segmental parameters [pulse wave velocity (PWV) and viscous energy loss (VEL)] were generated during postprocessing. The Student's t-test or Mann-Whitney test was used to compare flow dynamics among the three groups. Results: A total of 11 patients with TAAA (mean age 53.2±11.9 years; 10 males), 19 patients with AAA (mean age 58.0±11.7 years; 16 males), and 21 controls (mean age 55.4±15.0 years; 19 males) were analyzed. The patients with TAAA demonstrated a significantly higher RF and lower Vmax in the aortic arch compared to healthy controls. The whole length of the aorta in patients with TAAA was characterized by lower WSS, predominantly in the planes of pulmonary artery bifurcation and the middle infrarenal planes (all P values <0.001). As for segmental hemodynamics, compared to controls, patients with TAAA had a significantly higher PWV in the thoracic aorta (TAAA: median 11.41 m/s, IQR 9.56-14.32 m/s; control: median 7.21 m/s, IQR 5.57-7.79 m/s; P<0.001) as did those with AAA (AAA: median 8.75 m/s, IQR 7.35-10.75 m/s; control: median 7.21 m/s, IQR 5.57-7.79 m/s; P=0.024). Moreover, a greater VEL was observed in the whole aorta and abdominal aorta in patients with TAAA. Conclusions: Patients with TAAA exhibited a stiffer aortic wall with a lower WSS and a greater VEL for the whole aorta, which was accompanied by a higher RF and lower peak velocity in the dilated portion of the aorta.

3.
Quant Imaging Med Surg ; 14(2): 1873-1890, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38415143

RESUMO

Background: Four-dimensional flow magnetic resonance imaging (4D flow MRI) is a promising new technology with potential clinical value in hemodynamic quantification. Although an increasing number of articles on 4D flow MRI have been published over the past decades, few studies have statistically analyzed these published articles. In this study, we aimed to perform a systematic and comprehensive bibliometric analysis of 4D flow MRI to explore the current hotspots and potential future directions. Methods: The Web of Science Core Collection searched for literature on 4D flow MRI between 2003 and 2022. CiteSpace was utilized to analyze the literature data, including co-citation, cooperative network, cluster, and burst keyword analysis. Results: A total of 1,069 articles were extracted for this study. The main research hotspots included the following: quantification and visualization of blood flow in different clinical settings, with keywords such as "cerebral aneurysm", "heart", "great vessel", "tetralogy of Fallot", "portal hypertension", and "stiffness"; optimization of image acquisition schemes, such as "resolution" and "reconstruction"; measurement and analysis of flow components and patterns, as indicated by keywords "pattern", "KE", "WSS", and "fluid dynamics". In addition, international consensus for metrics derived from 4D flow MRI and multimodality imaging may also be the future research direction. Conclusions: The global domain of 4D flow MRI has grown over the last 2 decades. In the future, 4D flow MRI will evolve towards becoming a relatively short scan duration with adequate spatiotemporal resolution, expansion into the diagnosis and treatment of vascular disease in other related organs, and a shift in focus from vascular structure to function. In addition, artificial intelligence (AI) will assist in the clinical promotion and application of 4D flow MRI.

4.
Magn Reson Med Sci ; 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38417875

RESUMO

A woman in her sixties with portosystemic shunt and hepatic encephalopathy underwent open mesenteric vein ligation, resulting in improved portal flow and blood ammonia. In this case, 4D flow MRI was a valuable diagnostic and follow-up tool, visualizing and quantifying physiological portal hemodynamics with features distinct from those of contrast-enhanced CT and digital subtraction angiography. Our case study highlights the value of 4D flow MRI for managing portosystemic shunts.

5.
Artigo em Inglês | MEDLINE | ID: mdl-37948001

RESUMO

OBJECTIVE: We evaluated the blood flow within the downstream aortic false lumen after frozen elephant trunk repair for acute aortic dissection and identified hemodynamic predictors of false lumen expansion and negative false lumen remodeling using four-dimensional flow magnetic resonance imaging. METHODS: Thirty-one patients (Stanford type A, n = 28; Stanford type B, n = 3) with patent false lumen who underwent frozen elephant trunk procedures for acute aortic dissection were included in this observational study. Each patient underwent computed tomography during the follow-up period and four-dimensional flow magnetic resonance imaging within 3 postoperative months. The false lumen volumetric expansion rate was calculated using computed tomography data. The direction and the rate of flow in the lower descending aortic false lumen were analyzed. Negative false lumen remodeling was defined as a volumetric increase of > 10% from the baseline volume. RESULTS: Negative false lumen remodeling had developed in 6 of the 31 patients during the observation period. Most of the false lumen flows were biphasic during systole. The range between peak and nadir flow rates was associated with the false lumen volumetric expansion rate (ß coefficient = 6.77; p < 0.01, R2 = 0.43). CONCLUSIONS: The range between peak and nadir flow rates may serve as a hemodynamic predictor of negative false lumen remodeling, enabling further treatment for patients at risk of expansion in the downstream aorta.

6.
J Cardiovasc Magn Reson ; 25(1): 60, 2023 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-37880721

RESUMO

BACKGROUND: The differences in pre- and early post-procedural blood flow dynamics between the two major types of bioprosthetic valves, the balloon-expandable valve (BEV) and self-expandable valve (SEV), in patients with aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR), have not been investigated. We aimed to investigate the differences in blood flow dynamics between the BEV and SEV using four-dimensional flow cardiovascular magnetic resonance (4D flow CMR). METHODS: We prospectively examined 98 consecutive patients with severe AS who underwent TAVR between May 2018 and November 2021 (58 BEV and 40 SEV) after excluding those without CMR because of a contraindication, inadequate imaging from the analyses, or patients' refusal. CMR was performed in all participants before (median interval, 22 [interquartile range (IQR) 4-39] days) and after (median interval, 6 [IQR 3-6] days) TAVR. We compared the changes in blood flow patterns, wall shear stress (WSS), and energy loss (EL) in the ascending aorta (AAo) between the BEV and SEV using 4D flow CMR. RESULTS: The absolute reductions in helical flow and flow eccentricity were significantly higher in the SEV group compared in the BEV group after TAVR (BEV: - 0.22 ± 0.86 vs. SEV: - 0.85 ± 0.80, P < 0.001 and BEV: - 0.11 ± 0.79 vs. SEV: - 0.50 ± 0.88, P = 0.037, respectively); there were no significant differences in vortical flow between the groups. The absolute reduction of average WSS was significantly higher in the SEV group compared to the BEV group after TAVR (BEV: - 0.6 [- 2.1 to 0.5] Pa vs. SEV: - 1.8 [- 3.5 to - 0.8] Pa, P = 0.006). The systolic EL in the AAo significantly decreased after TAVR in both the groups, while the absolute reduction was comparable between the groups. CONCLUSIONS: Helical flow, flow eccentricity, and average WSS in the AAo were significantly decreased after SEV implantation compared to BEV implantation, providing functional insights for valve selection in patients with AS undergoing TAVR. Our findings offer valuable insights into blood flow dynamics, aiding in the selection of valves for patients with AS undergoing TAVR. Further larger-scale studies are warranted to confirm the prognostic significance of hemodynamic changes in these patients.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valor Preditivo dos Testes , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Hemodinâmica , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Resultado do Tratamento , Desenho de Prótese
7.
Int J Cardiovasc Imaging ; 39(6): 1189-1202, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36820960

RESUMO

Changes in cardiovascular hemodynamics are closely related to the development of aortic regurgitation (AR), a type of valvular heart disease. Metrics derived from blood flows are used to indicate AR onset and evaluate its severity. These metrics can be non-invasively obtained using four-dimensional (4D) flow magnetic resonance imaging (MRI), where accuracy is primarily dependent on spatial resolution. However, insufficient resolution often results from limitations in 4D flow MRI and complex aortic regurgitation hemodynamics. To address this, computational fluid dynamics simulations were transformed into synthetic 4D flow MRI data and used to train a variety of neural networks. These networks generated super-resolution, full-field phase images with an upsample factor of 4. Results showed decreased velocity error, high structural similarity scores, and improved learning capabilities from previous work. Further validation was performed on two sets of in vivo 4D flow MRI data and demonstrated success in de-noising flow images. This approach presents an opportunity to comprehensively analyse AR hemodynamics in a non-invasive manner.


Assuntos
Insuficiência da Valva Aórtica , Aprendizado Profundo , Humanos , Insuficiência da Valva Aórtica/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo/fisiologia , Hidrodinâmica , Valor Preditivo dos Testes , Imageamento por Ressonância Magnética/métodos , Hemodinâmica , Imageamento Tridimensional/métodos
8.
Radiol Case Rep ; 18(3): 1302-1305, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36684633

RESUMO

The assessment of stent lumen patency via non-contrast-enhanced 2-dimensional time-of-flight magnetic resonance angiography (2D TOF MRA) is complex due to stent-related artifacts. However, an imaging technique using the phase-contrast method, which can reduce susceptibility to artifact, is available. Herein, we report the use of 3-dimensional velocity vector image obtained via 4-dimensional flow magnetic resonance imaging (4D flow MRI) for in-stent flow visualization after stent development in the right superficial femoral artery. Hence, instead of 2D TOF MRA, 4D flow MRI using the phase-contrast method can be performed to assess stent lumen patency as it reduces stent-related artifacts.

9.
Jpn J Radiol ; 41(6): 625-636, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36656540

RESUMO

PURPOSE: The mechanisms underlying the morphological changes in liver cirrhosis remain unknown. This study aimed to clarify the relationship between fibrotic hepatic morphology and portal hemodynamic changes using four-dimensional flow magnetic resonance imaging (MRI). MATERIALS AND METHODS: Overall, 100 patients with suspected liver disease who underwent 3-T MRI were evaluated in this retrospective study. Liver fibrosis was assessed using a combination of visual assessment of the hepatic morphology and quantitative measures, including the fibrosis-4 index and aspartate transaminase-to-platelet ratio. It was classified into three groups according to the severity of fibrosis as follows: A (normal), B (mild-to-moderate), and C (severe). Quantitative indices, including area (mm2), net flow (mL/s), and average velocity (cm/s), were measured in the right portal vein (RPV) and left portal vein (LPV), and were compared across the groups using the Kruskal-Wallis and Mann-Whitney U tests. RESULTS: Among the 100 patients (69.1 ± 12.1 years; 59 men), 45, 35, and 20 were categorized into groups A, B, and C, respectively. The RPV area significantly differed among the groups (from p < 0.001 to p = 0.001), showing a gradual decrease with fibrosis progression. Moreover, the net flow significantly differed between groups A and B and between groups A and C (p < 0.001 and p < 0.001, respectively), showing a decrease during the early stage of fibrosis. In the LPV, the net flow significantly differed among the groups (from p = 0.001 to p = 0.030), revealing a gradual increase with fibrosis progression. CONCLUSION: The atrophy-hypertrophy complex, which is a characteristic imaging finding in advanced cirrhosis, was closely associated with decreased RPV flow in the early stage of fibrosis and a gradual increase in LPV flow across all stages of fibrosis progression.


Assuntos
Hemodinâmica , Cirrose Hepática , Masculino , Humanos , Estudos Retrospectivos , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Fibrose , Veia Porta/diagnóstico por imagem , Imageamento por Ressonância Magnética , Fígado/patologia
10.
Acta Radiol ; 64(4): 1462-1468, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36325676

RESUMO

BACKGROUND: The effectiveness of four-dimensional (4D) flow magnetic resonance imaging (MRI) for assessing hemodynamic changes before and after balloon-occluded retrograde transvenous obliteration (BRTO) remains unclear. PURPOSE: To evaluate the feasibility of 4D flow MRI for assessing hemodynamic changes in the portal venous system before and after BRTO. MATERIAL AND METHODS: We included 10 patients (7 men, 3 women; mean age = 67 years) with liver cirrhosis who had a high risk of gastric variceal bleeding or hepatic encephalopathy. Non-contrast 4D flow MRI of the upper abdomen was performed before and after BRTO. In addition, we compared the blood flow rates in the portal vein (PV), superior mesenteric vein (SMV), splenic vein (SV), left renal vein, and inferior vena cava before and after BRTO. Moreover, the flow directions of the SMV and SV before and after BRTO were assessed using both portography and 4D flow MRI. RESULTS: There was a significant post-BRTO increase in the blood flow rate in the PV and SV (P < 0.05). There was no significant post-BRTO change in the blood flow rates in the SMV, inferior vena cava, and left renal vein. In four patients, portography confirmed that hepatofugal flow in the SV and SMV changed to hepatopetal flow after BRTO. Moreover, 4D flow MRI correctly assessed the flow directions in the SMV and SV in 70%-100% of the patients. CONCLUSION: 4D flow MRI can be used to detect hemodynamic changes in the portal venous system before and after BRTO.


Assuntos
Oclusão com Balão , Varizes Esofágicas e Gástricas , Masculino , Humanos , Feminino , Idoso , Varizes Esofágicas e Gástricas/diagnóstico por imagem , Varizes Esofágicas e Gástricas/terapia , Estudos de Viabilidade , Oclusão com Balão/métodos , Hemorragia Gastrointestinal/terapia , Imageamento por Ressonância Magnética , Abdome , Hemodinâmica , Resultado do Tratamento
11.
Quant Imaging Med Surg ; 12(2): 992-1003, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35111600

RESUMO

BACKGROUND: We previously reported that to-and-fro blood movement near the pulmonary vein stump was particularly prominent after left upper lobectomy compared with other lobectomy, which may be the cause of the high susceptibility of pulmonary vein thrombus after left upper lobectomy. The aim of the present study was to compare the hemodynamics in patients who developed pulmonary vein thrombus after left upper lobectomy with those in patients who did not develop pulmonary vein thrombus using four-dimensional flow magnetic resonance imaging (4D MRI). METHODS: This was a retrospective evaluation of a prospectively collected clinical and radiological database of 37 patients who underwent 4D MRI 7 days after left upper lobectomy for lung cancer (n=37). We obtained two parameters by 4D MRI: the grade of to-and-fro blood movement and the flow energy loss around the pulmonary vein stump. The length of the pulmonary vein stump, a known risk factor for pulmonary vein thrombus, was also measured. RESULTS: According to a scatterplot of the grade of to-and-fro blood movement versus the flow energy loss, patients with pulmonary vein thrombus (n=15) were concentrated in an area which appears to be a 'dangerous' hemodynamic condition. There were few patients without pulmonary vein thrombus in this 'dangerous' area, except for one who unfortunately developed delayed pulmonary vein thrombus and cerebral infarction. We proposed a formula using the 4D MRI-derived parameters based on a stepwise multiple regression analysis that was more closely associated with the development of pulmonary vein thrombus than the length of the pulmonary vein stump (area under the receiver operating characteristics curve: 0.918 vs. 0.705, P=0.0500). CONCLUSIONS: We proposed the existence of a 'dangerous' hemodynamic condition responsible for pulmonary vein thrombus formation. 4D MRI before the development of pulmonary vein thrombus may help identify patients requiring preventive therapy against pulmonary vein thrombus and subsequent thromboembolic complications.

12.
Europace ; 24(8): 1284-1290, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-34919657

RESUMO

AIMS: This study aimed to investigate the intraventricular blood flow pattern of patients with left bundle branch block (LBBB) using four-dimensional flow magnetic resonance imaging (4D-flow MRI). METHODS AND RESULTS: We performed 4D-flow MRI for 16 LBBB patients (LBBB group) and 16 propensity score-matched patients with a normal QRS duration (non-LBBB group). The energy loss (EL) in the left ventricle was evaluated. In both groups, blood flow from the mitral valve to the apex of the heart and left ventricular (LV) outflow tract during LV diastole were observed. Vortices were also observed in both groups. There were two patterns of vortices: unidirectional clockwise rotation and counterclockwise rotation taking place from the mid-diastole to the systole (reverse pattern). The reverse pattern was observed significantly more frequently in the LBBB group (LBBB 94% vs. non-LBBB 19%, P < 0.001). The interobserver agreement for the streamline analysis was good (kappa = 0.68). The maximum EL was significantly higher in the LBBB group [LBBB 12 (11-15) mW vs. non-LBBB 8.0 (6.2-9.7) mW, P < 0.001]. CONCLUSION: Left bundle branch block patients may suffer from inefficient LV haemodynamics reflected by non-physiological counterclockwise vortices and increased EL. Thus, the shape of the vortices and EL in the left ventricle can serve as markers of LV mechanical dyssynchrony in LBBB patients and could be investigated as predictors of response to cardiac resynchronization therapy.


Assuntos
Terapia de Ressincronização Cardíaca , Disfunção Ventricular Esquerda , Bloqueio de Ramo/diagnóstico por imagem , Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca/métodos , Eletrocardiografia/métodos , Ventrículos do Coração , Humanos , Imageamento por Ressonância Magnética , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia , Função Ventricular Esquerda
13.
Diagnostics (Basel) ; 11(10)2021 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-34679588

RESUMO

Assessment of carotid bulb hemodynamics using four-dimensional (4D) flow magnetic resonance imaging (MRI) requires accurate segmentation of recirculation regions that is frequently hampered by limited resolution. This study aims to improve the accuracy of 4D flow MRI carotid bulb segmentation and subsequent recirculation regions analysis. Time-of-flight (TOF) MRI and 4D flow MRI were performed on bilateral carotid artery bifurcations in seven healthy volunteers. TOF-MRI data was segmented into 3D geometry for computational fluid dynamics (CFD) simulations. ITK-SNAP segmentation software was included in the workflow for the semi-automatic generation of 4D flow MRI angiographic data. This study compared the velocities calculated at the carotid bifurcations and the 3D blood flow visualization at the carotid bulbs obtained by 4D flow MRI and CFD. By applying ITK-SNAP segmentation software, an obvious improvement in the 4D flow MRI visualization of the recirculation regions was observed. The 4D flow MRI images of the recirculation flow characteristics of the carotid artery bulbs coincided with the CFD. A reasonable agreement was found in terms of velocity calculated at the carotid bifurcation between CFD and 4D flow MRI. However, the dispersion of velocity data points relative to the local errors of measurement in 4D flow MRI remains. Our proposed strategy showed the feasibility of improving recirculation regions segmentation and the potential for reliable blood flow visualization in 4D flow MRI. However, quantitative analysis of recirculation regions in 4D flow MRI with ITK-SNAP should be enhanced for use in clinical situations.

14.
Vasc Endovascular Surg ; 55(7): 696-701, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34078199

RESUMO

BACKGROUND: Four-dimensional flow magnetic resonance imaging (4D flow MRI) can accurately visualize and quantify flow and provide hemodynamic information such as wall shear stress (WSS). This imaging technique can be used to obtain more insight in the hemodynamic changes during cardiac cycle in the true and false lumen of uncomplicated acute Type B Aortic Dissection (TBAD). Gaining more insight of these forces in the false lumen in uncomplicated TBAD during optimal medical treatment, might result in prediction of adverse outcomes. METHODS: A porcine aorta dissection model with an artificial dissection was positioned in a validated ex-vivo circulatory system with physiological pulsatile flow. 4D flow MR images with 3 set heartrates (HR; 60 bpm, 80 bpm and 100 bpm) were acquired. False lumen volume per cycle (FLV), mean and peak systolic WSS were determined from 4D flow MRI data. For validation, the experiment was repeated with a second porcine aorta dissection model. RESULTS: During both experiments an increase in FLV (initial experiment: ΔFLV = 2.05 ml, p < 0.001, repeated experiment: ΔFLV = 1.08 ml, p = 0.005) and peak WSS (initial experiment: ΔWSS = 1.2 Pa, p = 0.004, repeated experiment: ΔWSS = 1.79 Pa, p = 0.016) was observed when HR increased from 60 to 80 bpm. Raising the HR from 80 to 100 bpm, no significant increase in FLV (p = 0.073, p = 0.139) was seen during both experiments. The false lumen mean WSS increased significant during initial (2.71 to 3.85 Pa; p = 0.013) and non-significant during repeated experiment (3.22 to 4.00 Pa; p = 0.320). CONCLUSION: 4D flow MRI provides insight into hemodynamic dimensions including WSS. Our ex-vivo experiments showed that an increase in HR from 60 to 80 bpm resulted in a significant increase of FLV and WSS of the false lumen. We suggest that strict heart rate control is of major importance to reduce the mean and peak WSS in uncomplicated acute TBAD. Because of the limitations of an ex-vivo study, 4D flow MRI will have to be performed in clinical setting to determine whether this imaging model would be of value to predict the course of uncomplicated TBAD.


Assuntos
Aorta/diagnóstico por imagem , Aneurisma Aórtico/diagnóstico por imagem , Dissecção Aórtica/diagnóstico por imagem , Hemodinâmica , Imageamento por Ressonância Magnética , Imagem de Perfusão , Dissecção Aórtica/fisiopatologia , Animais , Aorta/fisiopatologia , Aneurisma Aórtico/fisiopatologia , Velocidade do Fluxo Sanguíneo , Modelos Animais de Doenças , Frequência Cardíaca , Valor Preditivo dos Testes , Fluxo Sanguíneo Regional , Estresse Mecânico , Sus scrofa , Fatores de Tempo
15.
Eur J Cardiothorac Surg ; 60(5): 1064-1072, 2021 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-34000001

RESUMO

OBJECTIVES: This study aimed to explore the flow dynamics factors affecting turbulence formation in the false lumen (FL) of aortic dissection using four-dimensional flow magnetic resonance imaging (4D flow MRI). This study also aimed to uncover risk factors affecting late complications of aortic dissection. METHODS: Thirty-three aortic dissection patients were examined using 4D flow MRI for quantitative flow dynamics (gross flow, velocity and regurgitant fraction) and turbulence visualization (helix and vortex with three-point visual grading) in the FL. The incidence of late complications (rupture or prophylactic intervention) was also obtained prospectively. RESULTS: The helix grade was correlated with FL gross flow (rS = 0.55, P < 0.001) and FL velocity (rS = 0.45, P = 0.008). The vortex grade was also correlated with FL gross flow (rS = 0.70, P < 0.001) and FL velocity (rS = 0.67, P < 0.001). Comparative analysis of patients with complications and stable patients revealed that patients with complications exhibited higher FL gross flow [41.7 (interquartile range, IQR 29.1-59.7) vs 17.7 (IQR 9.0-42.0) ml/s; P = 0.01], higher helix grade [2 (IQR 1.25-2) vs 0 (IQR 0-1); P = 0.001] and higher vortex grade [2 (IQR 1-2) vs 0 (IQR 0-2); P = 0.01]. CONCLUSIONS: Using 4D flow MRI analysis, we showed that turbulence formation depends on flow volume and velocity in the FL. Patients with high-volume turbulent flow in their FL are at higher risk of late complications; therefore, close follow-up and aggressive prophylactic intervention may improve their survival. CLINICAL TRIAL REGISTRATION NUMBER: Nippon Medical School Hospital Institutional Review Board approved this observational study in September 2018 (No. 30-08-986).


Assuntos
Dissecção Aórtica , Hemodinâmica , Dissecção Aórtica/diagnóstico por imagem , Aorta , Velocidade do Fluxo Sanguíneo , Humanos , Imageamento por Ressonância Magnética
16.
J Pers Med ; 11(4)2021 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-33808514

RESUMO

A multimodality approach was applied using four-dimensional flow magnetic resonance imaging (4D flow MRI), time-of-flight magnetic resonance angiography (TOF-MRA) signal intensity gradient (SIG), and computational fluid dynamics (CFD) to investigate the 3D blood flow characteristics and wall shear stress (WSS) of the cerebral arteries. TOF-MRA and 4D flow MRI were performed on the major cerebral arteries in 16 healthy volunteers (mean age 34.7 ± 7.6 years). The flow rate measured with 4D flow MRI in the internal carotid artery, middle cerebral artery, and anterior cerebral artery were 3.8, 2.5, and 1.2 mL/s, respectively. The 3D blood flow pattern obtained through CFD and 4D flow MRI on the cerebral arteries showed reasonable consensus. CFD delivered much greater resolution than 4D flow MRI. TOF-MRA SIG and CFD WSS of the major cerebral arteries showed reasonable consensus with the locations where the WSS was relatively high. However, the visualizations were very different between TOF-MRA SIG and CFD WSS at the internal carotid artery bifurcations, the anterior cerebral arteries, and the anterior communicating arteries. 4D flow MRI, TOF-MRA SIG, and CFD are complementary methods that can provide additional insight into the hemodynamics of the human cerebral artery.

17.
J Magn Reson Imaging ; 53(6): 1744-1751, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33491233

RESUMO

The effects of morphologic abnormalities, including sigmoid sinus wall dehiscence (SSWD), transverse sinus stenosis (TSS), and sigmoid sinus diverticulum (SSD), on hemodynamics in venous pulsatile tinnitus (PT) patients have not been established. The aim of this study was to evaluate the effects of SSWD, TSS, and SSD on the hemodynamics of transverse-sigmoid sinus in venous PT patients. This was a prospective study with 44 venous PT patients and 12 healthy controls. A 3 T/four-dimensional (4D) flow magnetic resonance imaging with fast field echo was used. Computed tomography arteriography/venography was used to assess ipsilateral SSWD, TSS, and SSD. Maximum velocity (Vmax ), average velocity (Vavg ), and average flow (Flowavg ) were measured. Blood flow patterns were independently assessed by three neuroradiologists. One-way analysis of variance or Kruskal-Wallis test was also used. On the symptomatic side, all patients had SSWD, 33 patients had TSS, and 22 patients had SSD. Compared with healthy controls, patients with TSS, without TSS, with SSD, and without SSD all showed higher Vmax (all p < 0.050), Vavg (all p < 0.050), and Flowavg (all p < 0.050). Patients with TSS showed higher Vmax (p < 0.050) and Vavg (p < 0.050) than those without TSS, and no significant difference in Flowavg was found between the two groups (p = 0.408). No significant differences in Vmax , Vavg , and Flowavg were found between patients with and without SSD (all p = 1.000). Jet-like flow in the stenosis and downstream of the stenosis was observed in all patients with TSS. Vortex in SSD was observed in 15 patients with SSD (68%). High blood velocity and flow may be characteristic markers of venous PT. SSWD may be a necessary condition for venous PT. TSS may further increase the blood velocity and form a jet-like flow. SSD may be related to vortex formation but had no significant effect on blood velocity and flow. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 3.


Assuntos
Zumbido , Cavidades Cranianas , Hemodinâmica , Humanos , Imageamento por Ressonância Magnética , Estudos Prospectivos , Zumbido/diagnóstico por imagem
18.
J Magn Reson Imaging ; 53(6): 1841-1850, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33354852

RESUMO

Stereotactic radiosurgery (SRS) is used to treat cerebral arteriovenous malformations (AVMs). However, early evaluation of efficacy is difficult as structural magnetic resonance imaging (MRI)/magnetic resonance angiography (MRA) often does not demonstrate appreciable changes within the first 6 months. The aim of this study was to evaluate the use of four-dimensional (4D) flow MRI to quantify hemodynamic changes after SRS as early as 2 months. This was a retrospective observational study, which included 14 patients with both pre-SRS and post-SRS imaging obtained at multiple time points from 1 to 27 months after SRS. A 3T MRI Scanner was used to obtain T2 single-shot fast spin echo, time-of-flight MRA, and postcontrast 4D flow with three-dimensional velocity encoding between 150 and 200 cm/s. Post-hoc two-dimensional cross-sectional flow was measured for the dominant feeding artery, the draining vein, and the corresponding contralateral artery as a control. Measurements were performed by two independent observers, and reproducibility was assessed. Wilcoxon signed-rank tests were used to compare differences in flow, circumference, and pulsatility between the feeding artery and the contralateral artery both before and after SRS; and differences in nidus size and flow and circumference of the feeding artery and draining vein before and after SRS. Arterial flow (L/min) decreased in the primary feeding artery (mean: 0.1 ± 0.07 vs. 0.3 ± 0.2; p < 0.05) and normalized in comparison to the contralateral artery (mean: 0.1 ± 0.07 vs. 0.1 ± 0.07; p = 0.068). Flow decreased in the draining vein (mean: 0.1 ± 0.2 vs. 0.2 ± 0.2; p < 0.05), and the circumference of the draining vein also decreased (mean: 16.1 ± 8.3 vs. 15.7 ± 6.7; p < 0.05). AVM volume decreased after SRS (mean: 45.3 ± 84.8 vs. 38.1 ± 78.7; p < 0.05). However, circumference (mm) of the primary feeding artery remained similar after SRS (mean: 15.7 ± 2.7 vs. 16.1 ± 3.1; p = 0.600). 4D flow may be able to demonstrate early hemodynamic changes in AVMs treated with radiosurgery, and these changes appear to be more pronounced and occur earlier than the structural changes on standard MRI/MRA. Level of Evidence: 4 Technical Efficacy Stage: 1.


Assuntos
Malformações Arteriovenosas Intracranianas , Radiocirurgia , Estudos Transversais , Hemodinâmica , Humanos , Malformações Arteriovenosas Intracranianas/diagnóstico por imagem , Malformações Arteriovenosas Intracranianas/cirurgia , Imageamento por Ressonância Magnética , Reprodutibilidade dos Testes , Estudos Retrospectivos , Resultado do Tratamento
19.
J Thorac Dis ; 12(10): 5542-5551, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33209387

RESUMO

BACKGROUND: Pulmonary vein (PV) stump thrombus, a known source of cerebral infarction, develops almost exclusively after left upper lobectomy; however, the mechanism remains unclear. We therefore evaluated the hemodynamics in the left atrium with four-dimensional flow magnetic resonance imaging (4D-flow MRI), which enables the simultaneous depiction of blood flow at three locations and the evaluation of hemodynamics. METHODS: 4D-flow MRI was basically performed 7 days after lobectomy for cancer arising in the right upper lobe (n=11), right lower lobe (n=8), left upper lobe (n=13), or left lower lobe (n=8). We evaluated dynamic blood movement from the ipsilateral remaining PV, the resected PV stump, and the contralateral PVs into the left atrium using 4D-flow MRI. RESULTS: There were some characteristic blood flow patterns that seemed to either promote or prevent PV stump thrombus. Promotive flow patterns were significantly more frequent and preventive flow patterns were significantly less frequent in patients who had undergone left upper lobectomy than in those who had undergone other lobectomy. Accordingly, the degree of blood turbulence near the vein stump, as measured by the extent of change in the blood movement, was significantly higher in patients who had undergone left upper lobectomy than in patients who had undergone other lobectomy. CONCLUSIONS: Our study revealed that left upper lobectomy likely causes blood turbulence near the vein stump through complicated blood streams in the left atrium, which can play a part in the development of vein stump thrombus. Further study to identify patients at high risk of vein stump thrombus is warranted.

20.
Semin Thorac Cardiovasc Surg ; 32(2): 211-217, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31546005

RESUMO

It is known that the elasticity of the thoracic aorta decreases when it is covered with endografts. It remains to be clarified, however, whether endografts in the descending aorta affect aortic stiffening in the ascending aorta. We analyzed 46 patients who underwent thoracic endovascular aortic repair for descending thoracic aortic aneurysm between January 2008 and June 2016. We calculated the preoperative and postoperative rate of enlargement of the mid-ascending aorta using enhanced computed tomography. In 3 of these patients, we evaluated the peak systolic and time-averaged wall shear stress and relative cross-section area change at the level of the mid-ascending aorta using 4-dimensional flow magnetic resonance imaging. The postoperative rate of enlargement of the mid-ascending aorta was significantly greater than the preoperative rate (0.78 [0.31-1.38] mm/y vs 0.32 [0.12-0.60] mm/y; P < 0.001). In 2 of the 3 patients analyzed by 4-dimensional flow magnetic resonance imaging, the waveform of time-averaged wall shear stress had changed, and the relative cross-section area change decreased after thoracic endovascular aortic repair. There were no secondary surgical interventions for the ascending aorta after thoracic endovascular aortic repair. The rate of enlargement of the ascending aorta may be affected by the change in wall shear stress or aortic stiffening after thoracic endovascular aortic repair.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Hemodinâmica , Remodelação Vascular , Idoso , Idoso de 80 Anos ou mais , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/fisiopatologia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/fisiopatologia , Aortografia , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Rigidez Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...