Rev Bras Ortop (Sao Paulo) ; 59(Suppl 1): e34-e38, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39027185

RESUMO

The most frequent skeletal injuries are hand fractures, which constitute around 20% of all fractures. Fractures of the phalanx are usual, comprising 6% of all fractures. Proximal phalanx fractures arise more often. The main goals of the care are to repair the anatomy, reduce the damage to soft tissue, and mobilize the damaged fingers as soon as stabilization of the fracture allows it. The present report is intended to examine the clinical and radiation effects of proximal phalanx fractures in patients treated with intramedullary screw fixation who underwent closed reduction. We report three consecutive cases of proximal phalanx fracture: two basal fractures and one simple shaft fracture. They were treated surgically with closed reduction with intramedullary headless compression screws. The preoperative magnitude of the angulation of the proximal phalanx averaged 30.3° (range: 13° to 42°). Two patients presented rotational deformity. The clinical findings were measured using the abbreviated version of the Disabilities of the Arm, Shoulder and Hand (Quick-DASH) questionnaire, and the range of motion and functional results were assessed. Complications were observed over a span of at least 3 months. The patients displayed complete active flexion-extension proximal interphalangeal joint and flexion-extension metacarpophalangeal joint without rotative deformity. The scores on the QuickDASH were satisfactory (mean: 2.3; range: 0 to 4.5). No secondary surgeries were performed, and complications were not observed. Intramedullary fixation of proximal phalanx fractures with cannulated tension screws has been shown to be a safe operation, resulting in outstanding functional performance and an early recovery. The fracture is minimized and properly consolidated by the patients.

3.
Rev Bras Ortop (Sao Paulo) ; 59(Suppl 1): e9-e11, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39027187

RESUMO

A 15-year-old male presented with multiple right-hand fractures, including a severely angulated small finger metacarpal neck fracture. Multiple closed attempts failed, and open reduction was performed. At surgery, the extensor tendon was found to be interposed within the fracture, thereby preventing closed reduction. The tendon was extricated from the fracture site, adequate reduction was obtained, and the fracture was stabilized using K-wires. The fracture united well, with good return of motion and strength. Extensor tendon interposition is a rare scenario associated with metacarpal neck fractures and should be suspected when there is complete loss of contact between the fracture ends and multiple attempts at closed reduction have failed.

4.
Zhongguo Gu Shang ; 37(6): 5835-90, 2024 Jun 25.
Artigo em Chinês | MEDLINE | ID: mdl-38910381

RESUMO

OBJECTIVE: To compare clinical effect between open reduction and fixation with cannulated screw and threaded rivet via posteromedial approach versus arthroscopic Endobutton plate fixation in treating posterior cruciate ligament avulsion fractures. METHODS: Clinical data of 38 patients with posterior cruciate ligament avulsion fractures from July 2020 to December 2021 were analyzed retrospectively, and divided into open reduction and internal fixation group (posterior medial approach hollow anchor system fixation) and arthroscopic fixation group (Endobutton with loop plate fixation under arthroscopy). There were 20 patients in open reduction and internal fixation group, including 16 males and 4 females, aged from 26 to 74 years old with an average of (42.9±18.8) years old;13 patients on the left side and 7 patients on the right side;12 patients were classified to typeⅡand 8 patiens with type Ⅲ according to Meyers-McKeever fractures classification;14 patients were gradeⅡand 6 patients were grade Ⅲ in back drawer test. There were 18 patients in arthroscopic fixation group, including 11 males and 7 females;aged from 24 to 70 years old with an average of (53.5±13.4) years old;11 patients on the left side and 7 patients on the right side;10 patients were classified to typeⅡand 8 patiens with type Ⅲ according to Meyers-McKeever fractures classification;11 patients were gradeⅡand 7 patients were grade Ⅲ in back drawer test. Operation time, blood loss, and quality of immediate reduction were compared between two groups. Knee range of motion, knee back drawer test, and International Knee Documentation Committee(IKDC) grading, KT2000 stability evaluation and Lysholm function score of knee joint were compared at 6 months after operation. RESULTS: All patients were followed up for 8 to 16 months with an average of (12.3±1.9) months. There were no complications such as incision infection, fracture malunion or non-union, and internal fixation loosening occurred. The avulsion fractures of knee joint were reached to imaging healing standard at 6 months after operation. Operation time and blood loss in open reduction and internal fixation group were (56.4±7.1) min and (63.2±10.2) ml, while (89.9±7.4) min and (27.7±8.7) ml in arthroscopic fixation group, respectively, and had significant difference between two groups (P<0.05). There were no differences in immediate reduction quality (χ2=0.257, P=0.612), knee joint range of motion at 6 months after opertaion (t=0.492, P=0.626), knee joint rear drawer test ( χ2=0.320, P=0.572), IKDC classification of knee joint (χ2=0.127, P=0.938), KT2000 stability evaluation (χ2=0.070, P=0.791), and knee Lysholm function score (t=0.092, P=0.282) between two groups. CONCLUSION: Posterior medial approach with hollow anchoring system fixation and arthroscopic Endobutton with loop plate fixation for the treatment of posterior cruciate ligament tibial occlusion avulsion fracture could achieve satisfactory clinical results, and arthroscopic surgery has less bleeding, but also has a longer learning curve and longer operation time than traditional incision surgery. The surgeon needs to make a choice according to clinical situation of patient and their own surgical inclination.


Assuntos
Artroscopia , Placas Ósseas , Fixação Interna de Fraturas , Ligamento Cruzado Posterior , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Artroscopia/métodos , Adulto , Idoso , Ligamento Cruzado Posterior/cirurgia , Ligamento Cruzado Posterior/lesões , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Estudos Retrospectivos , Fratura Avulsão/cirurgia , Pinos Ortopédicos
5.
Surg Radiol Anat ; 46(9): 1439-1445, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38858314

RESUMO

PURPOSE: This study shows the danger zone and the safety corridor in the lateral approach with bridge plating by measuring the distance between the lateral side of the plate positioned on the lateral aspect of the humerus and the radial nerve after it pierces the lateral intermuscular septum, in the different forearm positions. METHODS: Forty arms of 20 human cadavers were used, the radial nerve was identified and marked on the lateral surface the radial nerve at the exit of the lateral intermuscular septum and anteriorisation of the nerve in relation to the humeral shaft and the lateral epicondyle was also marked. The distances were measured with a digital caliper. A submuscular extraperiosteal corridor was created, proximally between the biceps brachialis and deltoid muscle and distally between the triceps and brachioradialis muscle, followed by the positioning of the low contact large fragments contoured plate with 14 combined holes (fixed and cortical angle), inserted from distal to proximal. Measurements were performed in four positions (elbow flexion with forearm pronation, elbow flexion with forearm supination, elbow extension with forearm pronation and elbow extension with forearm supination). RESULTS: Significant statistical differences occurred with the different positions, and the elbow flexion with forearm supination was shown to be the position that provides the safest submuscular extraperiosteal corridor in a lateral approach of the humerus. CONCLUSION: The danger zone of radial nerve is an area that extends from 15 cm to 5 cm proximal to the lateral epicondyle and the safest way to create a submuscular and extraperiosteal corridor in the lateral region of the humerus is with the elbow in flexion and the forearm in supination.


Assuntos
Placas Ósseas , Cadáver , Fixação Interna de Fraturas , Úmero , Nervo Radial , Humanos , Nervo Radial/anatomia & histologia , Masculino , Úmero/anatomia & histologia , Feminino , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/efeitos adversos , Idoso , Fraturas do Úmero/cirurgia , Idoso de 80 Anos ou mais , Antebraço/anatomia & histologia , Pessoa de Meia-Idade
6.
Eur J Orthop Surg Traumatol ; 34(5): 2225-2234, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38594456

RESUMO

OBJECTIVE: To determine the necessity of reduction in the treatment of overriding metaphyseal distal radius fractures (DRF) in children under 11 years. METHODS: In this systematic review and meta-analysis, PubMed, Embase, and Cochrane databases were searched to retrieve studies published from inception to 2023. Two reviewers independently screened for studies with observational or randomized control design comparing two treatments for overriding metaphyseal DRF in patients under 11 years: simple casting without reduction (SC group) versus closed reduction plus casting or pin fixation (CRC/F group); with varying outcomes reported (CRD471761). The risk of bias was assessed using the ROBINS-I tool. RESULTS: Out of 3,024 screened studies, three met the inclusion criteria, 180 children (mean age 7.1 ± 0.9 years) with overriding metaphyseal DRF: SC-group (n = 79) versus CRC/F-group (n = 101). Both treatment groups achieved 100% fracture consolidation without requiring further manipulation. The SC-group showed significantly fewer complications (mean difference [MD] 0.08; 95% CI [0.01, 0.53]; I2 = 22%; P < 0.009) and trends towards better sagittal alignment (MD 5.11; 95% CI [11.92, 1.71]; I2 = 94%; P < 0.14), less reinterventions (MD 0.31; 95% CI [0.01, 8.31]; P < 0.48), and fewer patients with motion limitation at the end of follow-up (MD 0.23; 95% CI [0.03,  1.98]; P < 0.18), although these findings were not statistically significant. CONCLUSIONS: Despite a limited number of studies comparing SC versus CRC/F in overriding DRF in children under 11 years, this study suggests that anatomical reduction is not necessary. Treating these fractures with SC, even when presenting with an overriding position, leads to reduced complications, shows a trend towards fewer reinterventions, improved sagittal alignment, and less limitation in patient motion. LEVEL OF EVIDENCE: Level III, Systematic review of Level-III studies.


Assuntos
Moldes Cirúrgicos , Redução Fechada , Fraturas do Rádio , Humanos , Fraturas do Rádio/terapia , Criança , Redução Fechada/métodos , Fixação de Fratura/métodos , Pinos Ortopédicos , Consolidação da Fratura , Pré-Escolar , Fraturas do Punho
7.
Rev Bras Ortop (Sao Paulo) ; 59(2): e318-e322, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38606129

RESUMO

A middle-aged female patient with a tibial plateau fracture combined with an avulsion of the tibial eminence was treated with a combination of medial plate fixation for the plateau and an arthroscopic aided nonabsorbable suture of the eminence. Our technique for tibial eminence avulsion fractures has no interference with tibial plateau osteosynthesis materials and has proven, once again, to have good results in the treatment of combined and complex injuries of the knee.

8.
BMC Musculoskelet Disord ; 25(1): 293, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627701

RESUMO

OBJECTIVE: To investigate the efficacy of using pre-sliding technique to prevent postoperative shortening of displaced femoral neck fracture fixed with femoral neck system (FNS). METHODS: Retrospective analysis of 110 cases of displaced femoral neck fracture treated with femoral neck system from September 2019 to November 2022 in our center, which were divided into 56 cases in the pre-sliding group and 54 cases in the traditional group. The baseline data such as gender, age, side, mechanism of injury, fracture type, operation time, intraoperative bleeding were recorded and compared between the two groups, and the quality of fracture reduction, shortening distance, Tip Apex Distance (TAD), union time, Harris score of the hip were also compared between the two groups. RESULTS: The TAD value of the pre-sliding group was smaller than that of the traditional group, and the difference was statistically significant (P < 0.001). The shortening distance in both groups on postoperative day 1 was smaller in the pre-sliding group than in the traditional group, but the difference was not statistically significant (P = 0.07), and the shortening distance was smaller than in the traditional group at 1, 3, 6, and 12 months postoperatively, and the difference was statistically significant (all P < 0.001). Of the 110 cases, 34 (30.9%) had moderate or severe shortening, of which 24 (44.4%) were in the traditional group and 10 (17.9%) in the pre-sliding group, and the difference was statistically significant (P < 0.001), and the Harris score at 1 year, which was higher in the pre-sliding group than in the traditional group, and the difference between the two groups was statistically significant (P < 0.001). There was no statistically significant difference in the comparison of baseline data such as gender, age, side, mechanism of injury, fracture type, operation time, intraoperative bleeding, and quality of reduction between the two groups (all P > 0.05), and no statistically significant difference in fracture healing time between the two groups (P = 0.113). CONCLUSION: The use of the pre-sliding technique of displaced femoral neck fracture fixed with FNS reduces the incidence of moderate and severe shortening, improves the postoperative TAD value, and improves the hip function scores, with a satisfactory midterm efficacy.


Assuntos
Fraturas do Colo Femoral , Colo do Fêmur , Humanos , Estudos Retrospectivos , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Resultado do Tratamento , Fraturas do Colo Femoral/diagnóstico por imagem , Fraturas do Colo Femoral/cirurgia
9.
Injury ; 55(6): 111564, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38640596

RESUMO

BACKGROUND: The purpose of this study was to compare the outcomes of femoral neck shortening between the femoral neck system (FNS) and the cannulated cancellous screws (CCS) for displaced femoral neck fractures in young adults PATIENTS AND METHODS: In this retrospective analysis, 225 patients aged 18-65 years with displaced femoral neck fracture were divided into two groups according to internal fixation: 135 patients in the FNS group and 90 patients in the CCS group. The length of hospital stay, duration of surgery, intraoperative blood loss, quality of reduction, extent of femoral neck shortening, incidence of femoral neck shortening, femoral neck shortening at each follow-up visit, Harris hip score (HHS), reoperation, and complications were compared between the two groups. RESULTS: The median follow-up time was 28.2 (26.0, 31.2) months in the FNS group and 30.2 (26.3, 34.7) months in the CCS group. The follow-up time, age, sex distribution, body mass index (BMI), mechanism of injury, injured side, length of hospital stay, time from injury to surgery, and fracture classification were similar between the groups. Duration of surgery was longer in the FNS group (65.0 (55.0, 87.0) min versus 55.0 (50.0, 65.0) min, P<0.001); intraoperative blood loss was greater in the FNS group (50.0 (20.0, 60.0) ml versus 20.0 (10.0, 35.0) ml, P<0.001). Femoral neck shortening was 2.4 (1.0, 4.5) mm in the FNS group versus 0.6 (0.0, 2.6) mm in the CCS group at 1 month postoperatively (P<0.001); 3.7 (1.8, 6.4) mm in the FNS group versus 1.2 (0.6, 3.8) mm in the CCS group at 3 months (P<0.001); 4.1(2.4, 7.7) mm in the FNS group versus 2.3 (1.1, 4.4) mm in the CCS group at 6 months (P<0.001); 4.2 (2.6, 7.7) mm in the FNS group versus 2.6 (1.3, 4.6) mm in the CCS group at 12 months (P<0.001); and 4.5 (2.8, 8.0) mm in the FNS group versus 2.8 (1.5, 4.8) mm in the CCS group at 18 months (P<0.001). The two groups showed no significant differences in HHS, reoperation, and reduction quality. CONCLUSION: Compared to CCS, FNS is deficient in preventing femoral neck shortening. Future research should focus on improving FNS in terms of preventing femoral neck shortening.


Assuntos
Parafusos Ósseos , Fraturas do Colo Femoral , Fixação Interna de Fraturas , Tempo de Internação , Humanos , Fraturas do Colo Femoral/cirurgia , Fraturas do Colo Femoral/fisiopatologia , Masculino , Feminino , Fixação Interna de Fraturas/métodos , Estudos Retrospectivos , Adulto , Pessoa de Meia-Idade , Adulto Jovem , Resultado do Tratamento , Tempo de Internação/estatística & dados numéricos , Adolescente , Reoperação/estatística & dados numéricos , Seguimentos , Consolidação da Fratura/fisiologia , Complicações Pós-Operatórias/prevenção & controle , Duração da Cirurgia , Colo do Fêmur/cirurgia , Perda Sanguínea Cirúrgica
10.
Eur Radiol ; 34(3): 1556-1566, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37658140

RESUMO

OBJECTIVE: Bioabsorbable magnesium-based alloy screws release gas upon resorption. The resulting findings in the adjacent soft tissues and joints may mimic infection. The aim of the study was to evaluate the ultrasound (US) findings in soft tissues and joints during screw resorption. METHODS: Prospectively acquired US studies from pediatric patients treated with magnesium screws were evaluated for screw head visibility, posterior acoustic shadowing, twinkling artifact, foreign body granuloma, gas (soft tissue, intra-articular), alterations of the skin and subcutaneous fat, perifascial fluid, localized fluid collections, hypervascularization, and joint effusion. RESULTS: Sixty-six US studies of 28 pediatric patients (nfemale = 9, nmale = 19) were included. The mean age of the patients at the time of surgery was 10.84 years; the mean time between surgery and ultrasound was 128.3 days (range = 6-468 days). The screw head and posterior acoustic shadowing were visible in 100% of the studies, twinkling artifact in 6.1%, foreign body granuloma in 92.4%, gas locules in soft tissue in 100% and intra-articular in 18.2%, hyperechogenicity of the subcutaneous fat in 90.9%, cobblestoning of the subcutaneous fat in 24.2%, loss of normal differentiation between the epidermis/dermis and the subcutaneous fat in 57.6%, localized fluid collection in 9.9%, perifascial fluid in 12.1%, hypervascularization in 27.3%, and joint effusion in 18.2%. CONCLUSION: US findings in pediatric patients treated with magnesium screws strongly resemble infection, but are normal findings in the setting of screw resorption. CLINICAL RELEVANCE STATEMENT: Bioabsorbable magnesium-based alloy screws release gas during resorption. The resulting US findings in the adjacent soft tissues and joints in pediatric patients may mimic infection, but are normal findings. KEY POINTS: • Bioabsorbable magnesium-based alloy screws release gas upon resorption. • The resulting ultrasound findings in children's soft tissues and joints closely resemble those of soft tissue infection or osteosynthesis-associated infection. • Be familiar with these ultrasound findings in order to avoid inadvertently misdiagnosing a soft tissue infection or osteosynthesis-associated infection.


Assuntos
Fraturas Ósseas , Granuloma de Corpo Estranho , Infecções dos Tecidos Moles , Humanos , Masculino , Feminino , Criança , Magnésio , Implantes Absorvíveis , Granuloma de Corpo Estranho/etiologia , Infecções dos Tecidos Moles/etiologia , Fraturas Ósseas/etiologia , Ligas , Fixação Interna de Fraturas/métodos , Parafusos Ósseos/efeitos adversos
11.
Rev. bras. ortop ; 59(2): 318-322, 2024. graf
Artigo em Inglês | LILACS | ID: biblio-1565379

RESUMO

Abstract A middle-aged female patient with a tibial plateau fracture combined with an avulsion of the tibial eminence was treated with a combination of medial plate fixation for the plateau and an arthroscopic aided nonabsorbable suture of the eminence. Our technique for tibial eminence avulsion fractures has no interference with tibial plateau osteosynthesis materials and has proven, once again, to have good results in the treatment of combined and complex injuries of the knee.


Resumo Uma paciente de meia-idade com fratura do platô tibial e avulsão da eminência tibial foi tratada com uma combinação de fixação do platô com placa medial e sutura da eminência com fio não absorvível auxiliada por artroscopia. Nossa técnica para fraturas com avulsão da eminência tibial não interfere nos materiais de osteossíntese do platô tibial e, mais uma vez, teve bons resultados no tratamento de lesões combinadas e complexas do joelho.


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , Artroscopia , Fraturas da Tíbia , Fixação Interna de Fraturas , Traumatismos do Joelho
12.
International Journal of Surgery ; (12): 207-211, 2024.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1018116

RESUMO

Femoral intertrochanteric fracture is one of the common types of fractures in the elderly. With the general improvement of medical and living standards, the number of elderly people is increasing, and the problem of osteoporosis has also become relatively prominent. Therefore, low violence can usually cause fractures in this area of the elderly, which has a significant negative impact on the quality of life of elderly patients. With the further development of medical technology and internal fixation materials, the emergence of proximal femoral nail antirotation(PFNA) has greatly improved the treatment effect of femoral intertrochanteric fractures in elderly patients. However, with the increasing number of patients treated, internal fixation failures have gradually been reported. In recent years, proximal femoral biomimetic intramedullary nail(PFBN) has been reported to have good clinical efficacy. Therefore, this article mainly elaborates on the theoretical basis, design characteristics, biomechanics, and clinical efficacy research of PFBN, providing more reference for the clinical treatment of femoral intertrochanteric fractures in elderly patients in the future.

13.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1024260

RESUMO

Objective:To investigate the clinical efficacy of two different internal fixations in the treatment of femoral intertrochanteric fractures in older adult patients.Methods:The clinical data of 152 older adult patients with femoral intertrochanteric fractures who were treated at the Second People's Hospital of Hefei from January 2019 to December 2022 were retrospectively analyzed. All patients underwent closed reduction and internal fixation surgery. They were divided into two groups based on the different types of internal fixations used. Among them, 76 patients received internal fixation using proximal femoral intramedullary nails (group A), while 76 patients received internal fixation using Intertan nails (group B). The intraoperative blood loss volume, surgical time, postoperative complications, fracture healing time, and hip joint function score were compared between the two groups.Results:The intraoperative blood loss volume in group A was (197.11 ± 37.85) mL, which was significantly less than that in group B [(226.84 ± 54.17) mL, t = 1.62, P < 0.001]. Surgical time in group A was (71.16 ± 15.64) minutes, which was significantly shorter than that in group B [(78.49 ± 15.88) minutes, t = 1.67, P < 0.001]. The fracture healing time in group A was (13.29 ± 0.94) weeks, which was not significantly different from that in group B [(13.20 ± 0.64) weeks, t = 0.33, P > 0.05]. However, the incidence of postoperative complications in group A was 5.26% (4/76), which was significantly higher than 1.32% (1/76) in group B ( χ2 = 4.04, P = 0.048). At 1 and 3 months and 1 year after surgery, the hip joint function score in group A was (63.13 ± 2.41) points, (73.50 ± 3.99) points, and (84.13 ± 7.57) points, respectively, and it was (68.65 ± 2.65) points, (79.07 ± 3.38) points, and (89.56 ± 7.71) points, respectively, in group B. At the above-mentioned time points, the difference in hip joint function score between the two groups was statistically significant ( t = 1.89, 2.48, 2.49, all P < 0.001). Conclusion:Both internal fixation methods have significant therapeutic effects on femoral intertrochanteric fractures. Internal fixation using Intertan nails leads to higher hip joint function scores and fewer postoperative complications compared with internal fixation using proximal femoral intramedullary nails, but it results in more blood loss and a longer surgical time.

14.
Chinese Journal of Trauma ; (12): 206-213, 2024.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1027025

RESUMO

Objective:To investigate the long-term efficacy of self-designed posterior atlas polyaxial screw-plate in the treatment of unstable atlas fracture.Methods:A retrospective case series study was conducted to analyze the clinical data of 20 patients with unstable atlas fracture who were admitted to Affiliated Honghui Hospital of Xi′an Jiaotong University from January 2011 to April 2013, including 14 males and 6 females, aged 23-60 years [(42.7±8.6)years]. All the patients were treated with internal fixation using self-designed posterior atlas polyaxial screw-plate. The operation time and intraoperative bleeding volume were recorded. The fracture reduction was evaluated by CT scan at 3 days after surgery. The bone healing was observed by X-ray (anterior-posterior and lateral views of the cervical spine) and CT scan at 9 months after surgery. The delayed spinal cord injuries were evaluated by Frankel grade at 1 and 2 years after surgery and at the last follow-up. The Visual Analogue Scale (VAS) before surgery, at 3 months, 1 year, 2 years after surgery and at the last follow-up were compared. The axial rotation, flexion and extension range of the cervical spine at 3 months, 1 year, 2 years after surgery and at the last follow-up were compared. Intraoperative and postoperative complications were observed.Results:All the patients were followed up for 121-148 months [(135.0±6.8)months]. The operation duration was 68-122 minutes [(86.0±14.1)minutes], with the intraoperative blood loss of 90-400 ml [(120.0±67.9)ml]. The CT scan of the cervical spine at 3 days after surgery showed all satisfactory fracture reduction. Satisfactory bone reunion was observed at 9 months after surgery. All patients were scaled as Frankel grade E at 1 year, 2 years and at the last follow-up after surgery, with no delayed spinal cord injuries observed. The VAS scores of the cervical spine at 3 months, 1 year, 2 years after surgery and at the last follow-up were 2.0(1.3, 3.0)points, 1.0(1.0, 1.8)points, 1.0(0.3, 1.0)points and 1.0(0.3, 1.0)points, which were significantly lower than that before surgery [7.0(6.0, 7.8)points] ( P<0.05), with significantly lower scores at 1-, 2-year after surgeny and at the last follow-up than at 3 months after surgery ( P<0.05). There were no significant differences among the other time points ( P>0.05). The axial rotation ranges of the cervical spine were (103.0±8.3)°, (128.3± 11.4)° and (129.8±13.6)° at 1 year, 2 years after surgery and at the last follow-up respectively, which were significantly higher than that at 3 months after surgery [(85.3±7.0)°] ( P<0.05); It was further improved at 2 years after surgery and at the last follow-up compared with that at 1 year after surgery ( P<0.05), with no significant difference at the last follow-up compared with that at 2 years after surgery ( P>0.05). The flexion and extension range of the cervical spine at 1 year, 2 years after surgery and at the last follow-up were (65.5±4.8)°, (78.3±6.5)° and (79.3±6.9)° respectively, which were significantly higher than that at 3 months after surgery [(54.3±4.4)°] ( P<0.05); It was further improved at 2 years after surgery and at the last follow-up compared with that at 1 year after surgery ( P<0.05), with no significant difference between the last follow-up and 2 years after surgery ( P>0.05). No intraoperative injuries such as arteriovenous injury were observed. No incision infection or dehiscence occurred after surgery, with no complications caused by long-term bed rest such as lung or urinary tract infection, pressure sore formation or deep vein thrombosis occurred. No loosening or breakage of the screw and atlas plate was observed at the long-term follow-up. One patient had mild cervical pain, snap during rotation, and limited range of motion at the last follow-up. Conclusion:Self-designed posterior atlas polyaxial screw-plate has merits including small surgical wounds, satisfactory reduction, solid fixation, obvious pain relief, effective preservation of the previous cervical motion, few complications, and satisfactory long-term efficacy in the treatment of unstable atlas fracture.

15.
Chinese Journal of Trauma ; (12): 221-228, 2024.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1027027

RESUMO

Objective:To compare the efficacy of the horizontal plate plus raft screws above the acetabulum and fixation with screws only for acetabular fractures combined with dome impaction in the aged patients.Methods:A retrospective cohort study was conducted to analyze the clinical data of 20 aged patients with acetabular fractures combined with dome impaction, who were admitted to Tianjin hospital between May 2013 and January 2023, including 5 males and 15 females, aged 61-84 years [(72.2±7.3)years]. According to Letournel and Judet classification, 13 patients had anterior column fracture, 5 anterior column fracture combined with posterior transverse fracture and 2 two-column fracture. All the patients underwent open reduction and internal fixation through an anterior approach. Of them, 11 patients were treated with the fixation with the horizonal plate plus raft screws above the acetabulum (plate plus raft screw group) and 9 with the screws only (screw only group). The operative time, intraoperative blood loss, and intraoperative fluoroscopy times were compared between the two groups. The quality of fracture reduction was evaluated with the Matta′s radiographic criteria at 3 days after surgery and the function of the hip joint was assessed with Merle D′Aubigné and Postel scoring system at 3 months after surgery and at the last follow-up as well as the excellent and good rate at te last follow-up. The occurrence of postoperative complications was observed.Results:All the patients were followed up for 6-18 months [(13.1±3.1)months]. There were no significant differences in the operative time, intraoperative blood loss or intraoperative fluoroscopy times between the two groups ( P>0.05). According to the Matta′s radiographic criteria at 3 days after surgery, patients with anatomical reduction and satisfactory reduction accounted 6 and 5 in the plate plus raft screw group, compared to 5 and 4 respectively in the screw only group ( P>0.05). The values of Merle D′Aubigné and Postel score at 3 months after surgery and at the last follow-up were (14.0±2.4)points and (15.8±2.2)points in the plate plus raft screw group, which were higher than those in the screw only group [(11.0±2.6)points and (13.0±3.1)points] ( P<0.01). The values of Merle D′Aubigné and Postel score at the last follow-up of both groups were further enhanced from those at 3 months after surgery ( P<0.01). At the last follow-up, 3 patients were rated excellent, 6 good, 1 fair and 1 poor in the plate plus raft screw group, with an excellent and good rate of 81.8%, while in the screw only group, 3 were rated good, 2 fair and 4 poor, with an excellent and good rate of 33.3% ( P<0.05). One patient in the plate plus raft screw group and 5 in the screw only group had displacement of the dome impaction fragment combined with traumatic arthritis after surgery ( P<0.05). Conclusion:For acetabular fractures combined with dome impaction in the aged patients, the horizontal plate plus raft screw above the acetabulum can effectively improve the function restoration of the hip joint and reduce the occurrence of the displacement of the dome impaction fragment and traumatic arthritis after surgery compared to the fixation with screws only.

16.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1027091

RESUMO

Objective:To evaluate the reliability of a region-locked 3D-printed template combined with a bi-directional matching scheme in assistance of screw placement for thoracolumbar fractures.Methods:From January 2019 to March 2023, 52 patients with thoracolumbar fracture were treated at Department of Orthopedics, The People's Hospital of Liyang. They were 29 males and 23 females, with an age of (58.2±13.3) years. They were divided into a template group and a free-hand group according to the different screw placements. In the template group of 25 cases, a region-locked 3D-printed template combined with a bi-directional matching scheme was used to assist the pedicle positioning; in the free-hand group of 27 cases, the free hand screw placement was assisted only by image data and C-arm fluoroscopy. The operation time, intraoperative fluoroscopy frequency, intraoperative blood loss, complications, and placement accuracy were compared between the 2 groups. Visual analogue scale (VAS), Oswestry disability index (ODI), and anterior height ratio of the injured vertebra were compared between preoperation, 1 week postoperation, and the final follow-up, as well as between the 2 groups.Results:There were no statistically significant differences in the preoperative general data between the 2 groups, showing comparability ( P>0.05). All patients were followed up for (11.2±4.2) months. The differences were not statistically significant between the 2 groups in intraoperative blood loss, rate of complications, VAS or ODI at preoperation, 1 week postoperation, or the final follow-up, or in anterior height ratio of the injured vertebra ( P>0.05). In the template group, the operation time [(80.1±18.5) min] was significantly longer than that in the free-hand group [(69.4±16.6) min], the intraoperative fluoroscopy frequency [2 (2, 3) times] significantly lower than that in the free-hand group [3 (3, 4) times], and the placement accuracy [98.4% (127/129)] significantly higher than that in the free-hand group [91.8% (112/122)] (all P<0.05). All patients showed significant improvements in VAS, ODI and anterior height ratio of the injured vertebra at postoperative 1 week compared with the preoperative values, and the improvements at the last follow-up were significantly larger than those at postoperative 1 week ( P<0.05). No injury to the spinal cord, nerve root or blood vessel was observed postoperatively. Conclusions:In the treatment of thoracolumbar fractures, the screw placement assisted by a region-locked 3D-printed template combined with a bi-directional matching scheme is better than free-hand screw placement in terms of improved accuracy and reduced fluoroscopy, but the former incurs longer operative exposure than the latter. There is no significant difference between the 2 methods of screw placement in clinical efficacy.

17.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1027099

RESUMO

Objective:To compare the medium and long-term efficacy between the deltoid split approach and the conventional deltopectoral approach in locking plate fixation for proximal humerus fractures.Methods:A retrospective study was performed in the 65 patients with proximal humerus fracture who had been operatively treated at Department of Orthopedics, The Third People's Hospital of Nantong from January 2018 to December 2020. They were 20 males and 45 females with an age of (64.6±9.2) years. Of them, 34 were assigned to fixation with proximal humerus internal locking system (PHILOS) through the deltoid split approach (minimally invasive group), and 31 to PHILOS fixation through the deltopectoral approach (conventional group). The 2 groups were compared in terms of general data, operation time, intraoperative blood loss, hospital stay, fracture union time, intraoperative fluoroscopy, postoperative 2-year imaging scores, and Constant-Murley shoulder score at the last follow-up.Results:There was no significant difference in the preoperative general data between the 2 groups, showing comparability ( P>0.05). In the minimally invasive group and the conventional group, respectively, the intraoperative blood loss was (97.9±16.6) mL and (155.8±27.4) mL, and the frequency of intraoperative fluoroscopy (12.0±1.8) times and (6.7±1.8) times, both showing a statistically significant difference ( P<0.05). There was no significant difference in operation time, hospital stay, or fracture union time ( P>0.05). All patients were followed up for (43.9±5.5) months. There was no statistically significant difference between the 2 groups in postoperative 2-year imaging scores ( P>0.05). Compared with the conventional group, patients in the minimally invasive group had significantly lower Constant-Murley strength scores and significantly lower Constant-Murley scores for the Neer four-part fractures ( P<0.05). Postoperatively, one case of screw protrusion and one case of complete ischemic necrosis occurred in both groups while one case of partial ischemic necrosis was observed in the minimally invasive group and 3 cases of partial ischemic necrosis were observed in the conventional group. Conclusions:In locking plate fixation for proximal humerus fractures, compared with the deltopectoral approach, the deltoid split approach shows advantages of less soft tissue damage, less intraoperative bleeding, and less destruction of the blood supply to the humeral head. However, the deltopectoral approach may be more appropriate for the Neer four-part fractures.

18.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1027104

RESUMO

Objective:To evaluate our self-designed pre-positioned 3D honeycomb guide device in the internal fixation with percutaneous cannulated screws for femoral neck fractures.Methods:A retrospective study was conducted to analyze the data of 60 patients with femoral neck fracture who had been treated with cannulated screw fixation at Department of Orthopaedics, Kunshan Hospital of Traditional Chinese Medicine Affiliated to Nanjing University of Traditional Chinese Medicine from June 2019 to June 2022. According to the difference in intraoperative positioning for placement of cannulated screws, the patients were divided into a study group of 30 cases whose placement of cannulated screws was assisted by our self-designed pre-positioned 3D honeycomb guide device, and a control group of 30 cases whose cannulated screws were positioned freehand. In the study group, there were 17 males and 13 females with an age of (44.9±9.2) years, and 2 cases of type Ⅱ, 18 cases of type Ⅲ, and 10 cases of type Ⅳ by the Garden classification. In the control group, there were 11 males and 19 females with an age of (43.5±7.9) years), and 1 case of type Ⅱ, 16 cases of type Ⅲ, and 13 cases of type Ⅳ by the Garden classification. Closed reduction and inverted triangle internal fixation with 3 cannulated screws were conducted for all fractures. The Garden crossline index, operation time, fluoroscopy frequency, needle drillings, fracture healing time, and Harris hip functional score at the last follow-up were compared between the 2 groups. The postoperative imaging indicators in the 2 groups were measured, including screw spacing, distance from screw to neck cortex, screw coverage area, parallel deviation between screws, and deviation from screw to neck axis.Results:There were no statistically significant differences in the baseline characteristics between the 2 groups, indicating comparability ( P>0.05). All patients were followed up for (14.4±1.9) months after surgery. In the study group, operation time [(33.1±5.5) min], fluoroscopy frequency [(13.7±2.2) times], needle drillings [(3.7±0.6) times], distance from screw to neck cortex [(12.4±2.8) mm], parallel deviation between screws in the anteroposterior view (2.2°±1.1°), parallel deviation between screws in the lateral view (2.4°±1.0°), deviation from screw to neck axis in the anteroposterior view (4.0°±0.9°) and deviation from screw to neck axis in the lateral view (3.2°±0.8°) were all significantly smaller than those in the control group [(46.5±8.6) min, (23.1±5.2) times, (11.0±2.2) times, (19.0±3.3) mm, 6.5°±2.6°, 7.1°±2.9°, 7.7°±2.6°, and 9.2°±3.1°] (all P<0.05). The screw spacing [(45.7±5.8) mm] and screw coverage area [(74.1±10.9) mm 2] in the study group were both significantly larger than those in the control group [(31.3±7.7) mm and (55.5±9.0) mm 2] ( P<0.05). There was no statistically significant difference between the 2 groups in Garden crossline index, fracture healing time, follow-up time, or Harris hip functional score at the last follow-up ( P>0.05). Follow-ups revealed 1 case of bone non-union in the study group and 2 cases of bone non-union and screw withdrawal in the control group, but no such complications as infection, deep vein thrombosis, screw penetration or rupture, or femoral head necrosis in either group. Conclusion:In the internal fixation with percutaneous cannulated screws for the treatment of femoral neck fractures, our self-designed pre-positioned 3D honeycomb guide device can shorten surgical time, significantly reduce fluoroscopy frequency and needle drillings, and effectively improve accuracy of screw placement.

19.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1027107

RESUMO

Objective:To evaluate the reliability and clinical application of a self-established classification system for the lower 1/3 humeral fractures in adults.Methods:A retrospective study was performed to analyze the 88 patients with lower 1/3 humeral fracture who had been admitted to Department of Orthopedics, The Second Hospital of Fuzhou between January 2013 and December 2020. There were 61 males and 27 females with an age of (34.6±12.7) years. The lower 1/3 humeral fractures were classified according to the location of the fracture line, displacement, and bone mass into 3 types: type Ⅰ: transverse and short oblique ones; type Ⅱ: oblique and spiral ones; type Ⅲ: oblique and spiral ones with butterfly-shaped bone mass. After a junior orthopedic surgeon, an intermediate orthopedic surgeon, a senior orthopedic surgeon, and a radiologist had learned this novel classification system, they were asked to classify the lower 1/3 humeral fractures in this cohort independently to assess the reliability of the classification system. Our treatments were based on this novel classification. Open reduction and internal fixation with a unilateral plate through a lateral approach was performed for type Ⅰ fractures, internal fixation with a unilateral plate plus compression screws through a lateral approach for type Ⅱ fractures, and double plate internal fixation through the ulnar and anterolateral approaches for type Ⅲ fractures. The functions of the radial, ulnar, and musculocutaneous nerves and fracture healing time were observed postoperatively. The shoulder and elbow functions were evaluated using Neer shoulder function score and Mayo elbow function score.Results:Of the 88 patients in this cohort, 20 were type Ⅰ, 25 type Ⅱ, and 43 type Ⅲ. The mean Kappa value for inter-observer reliability was 0.878 at the first stage and 0.914 at the second stage, and the mean Kappa value for intra-observer reliability was 0.950. All patients were followed up for (14.1±3.7) months. Iatrogenic injury to the radial nerve was observed in 2 patients, but no injury to the ulnar nerve, the musculocutaneous nerve or important blood vessels or failure of internal fixation was reported. All patients achieved bony union after (12.7±2.0) weeks. The maximum elbow flexion was 137.8°±4.8°, and the maximum elbow extension 2.4°±1.6°. The Mayo elbow function score was (92.0±3.1) points and the Neer shoulder function score (92.2±3.2) points.Conclusions:Our classification system for the lower 1/3 humeral fractures in adults is reliable. As the treatments corresponding to the novel classification system can achieve satisfactory clinical outcomes, the classification system has a clinical value.

20.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1027113

RESUMO

Objective:To compare the clinical efficacy between a single palmar lateral transverse approach and the modified Henry approach in the locking plate fixation for distal radius fractures.Methods:A retrospective study was conducted to analyze the data of 82 patients with distal radius fracture who had undergone locking plate fixation through either a single palmar lateral approach or the modified Henry approach between January 2016 and December 2022 at Department of Traumatic Orthopaedics, Taihe Hospital, Affiliated to Hubei University of Medicine. There were 25 males and 57 females, with an age of (53.8±12.7) years. Based on the difference in surgical approach, the patients were divided into a single transverse approach group ( n=42) and a modified Henry approach group ( n=40). The 2 groups were compared in terms of injury cause, injury location, time from injury to surgery, AO fracture classification, tourniquet time during surgery, incision length, fracture reduction, Patient and Observer Scar Assessment Scale (PSAS & OSAS) and Disability of the Arm, Shoulder, and Hand (DASH) score at the last follow-up, and complications after surgery. Results:There were no statistically significant differences in the baseline characteristics between the 2 groups, indicating comparability ( P>0.05). All patients were followed up for (8.2±3.5) months. Follow-ups revealed one case of injury to the palmar cutaneous branch of the median nerve but no other complications like infection, non-union, internal fixation failure, or tendon injury in the single transverse approach group. The single transverse approach group was significantly superior over the modified Henry approach group in incision length [(2.4±0.9) cm versus (5.3±1.6) cm], OSAS (8.1±4.2 versus 10.3±5.7), and PSAS (10.1±5.8 versus 14.7±6.4) ( P<0.05). There were no significant differences between the 2 groups in tourniquet time, fracture reduction quality, and DASH score at the last follow-up ( P>0.05). Conclusion:In locking plate fixation for distal radius fractures, in comparison with the modified Henry approach, a single palmar lateral approach is more minimally invasive so that more aesthetically pleasing outcomes can be achieved to facilitate patients' rapid return to work and society.