Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 410
Filtrar
1.
Res Pract Thromb Haemost ; 8(4): 102437, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38953051

RESUMO

Background: Implantation of a left ventricular assist device (LVAD) is a crucial therapeutic option for selected end-stage heart failure patients. However, major bleeding (MB) complications postimplantation are a significant concern. Objectives: We evaluated current risk scores' predictive accuracy for MB in LVAD recipients. Methods: We conducted an observational, single-center study of LVAD recipients (HeartWare or HeartMate-3, November 2010-December 2022) in the Netherlands. The primary outcome was the first post-LVAD MB (according to the International Society on Thrombosis and Haemostasis [ISTH] and Interagency Registry for Mechanically Assisted Circulatory Support [INTERMACS], and INTERMACS combined with intracranial bleeding [INTERMACS+] criteria). Mortality prior to MB was considered a competing event. Discrimination (C-statistic) and calibration were evaluated for the Hypertension, Abnormal Renal/Liver Function, Stroke, Bleeding History or Predisposition, Labile INR, Elderly, Drugs/Alcohol Concomitantly score, Hepatic or Renal Disease, Ethanol Abuse, Malignancy, Older Age, Reduced Platelet Count or Function, Re-Bleeding, Hypertension, Anemia, Genetic Factors, Excessive Fall Risk and Stroke score, Anticoagulation and Risk Factors in Atrial Fibrillation score, Outpatient Bleeding Risk Index, venous thromboembolism score, atrial fibrillation score, and Utah Bleeding Risk Score (UBRS). Results: One hundred four patients were included (median age, 64 years; female, 20.2%; HeartWare, 90.4%; HeartMate-3, 9.6%). The cumulative MB incidence was 75.7% (95% CI 65.5%-85.9%) by ISTH and INTERMACS+ criteria and 67.0% (95% CI 56.0%-78.0%) per INTERMACS criteria over a median event-free follow-up time of 1916 days (range, 59-4521). All scores had poor discriminative ability on their intended prediction timeframe. Cumulative area under the receiving operator characteristic curve ranged from 0.49 (95% CI 0.35-0.63, venous thromboembolism-BLEED) to 0.56 (95% CI 0.47-0.65, UBRS) according to ISTH and INTERMACS+ criteria and from 0.48 (95% CI 0.40-0.56, Anticoagulation and Risk Factors in Atrial Fibrillation) to 0.56 (95% CI 0.47-0.65, UBRS) per INTERMACS criteria. All models showed poor calibration, largely underestimating MB risk. Conclusion: Current bleeding risk scores exhibit inadequate predictive accuracy for LVAD recipients. There is a need for an accurate risk score to identify LVAD patients at high risk of MB who may benefit from patient-tailored antithrombotic therapy.

3.
Med Biol Eng Comput ; 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39004652

RESUMO

Percutaneous ventricular assist devices (pVADs) incorporated with admittance electrodes have been validated in animal studies for accurate instantaneous volumetric measurements. Since miniaturization of the pVAD profile is a priority to reduce vascular complications in patients, our study aimed to validate admittance measurements using three electrodes instead of the standard four. Complex admittance was measured between an electrode pair and a pVAD metallic blood-intake tip, both with finite element analysis and on the benchtop. The catheter and electrode arrays were first simulated inside prolate ellipsoid models of the left ventricle (LV) demonstrating current flow throughout all parts of the LV as well as minimal influence of off-center catheter placement in the recorded signal. Admittance measurements were validated in 3D-printed models of healthy and dilated hearts (100-400 mL end-diastolic volumes). Minimal interference between a pVAD motor and the current signal of our admittance system was demonstrated. A modified Wei's equation focused on three electrodes was developed to be compatible with reduced profile pVADs occurring clinically, incorporated with admittance electrodes and wires. The modified equation was compared against Wei's original equation showing improved accuracy of calculated volumes. Reducing electrode footprint can simplify the incorporation of Admittance technology on any pVAD, allowing for instantaneous recognition of native heart recovery and assistance with pVAD weaning.

4.
Circ Heart Fail ; 17(7): e011705, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38910557

RESUMO

BACKGROUND: Caregivers of patients with advanced heart failure may experience burden in providing care, but whether changes in patient health status are associated with caregiver burden is unknown. METHODS: This observational study included older patients (60-80 years old) receiving advanced surgical heart failure therapies and their caregivers at 13 US sites. Patient health status was assessed using the 12-item Kansas City Cardiomyopathy Questionnaire (range, 0-100; higher scores are better). Caregiver burden was assessed using the Oberst Caregiving Burden Scale, which measures time on task (OCBS-time) and task difficulty (OCBS-difficulty; range, 1-5; lower scores are better). Measurements occurred before surgery and 12 months after in 3 advanced heart failure cohorts: patients receiving long-term left ventricular assist device support; heart transplantation with pretransplant left ventricular assist device support; and heart transplantation without pretransplant left ventricular assist device support. Multivariable linear regression was used to identify predictors of change in OCBS-time and OCBS-difficulty at 12 months. RESULTS: Of 162 caregivers, the mean age was 61.0±9.4 years, 139 (86%) were female, and 140 (86%) were the patient's spouse. At 12 months, 99 (61.1%) caregivers experienced improved OCBS-time, and 61 (37.7%) experienced improved OCBS-difficulty (versus no change or worse OCBS). A 10-point higher baseline 12-item Kansas City Cardiomyopathy Questionnaire predicted lower 12-month OCBS-time (ß=-0.09 [95% CI, -0.14 to -0.03]; P<0.001) and OCBS-difficulty (ß=-0.08 [95% CI, -0.12 to -0.05]; P<0.001). Each 10-point improvement in the 12-item Kansas City Cardiomyopathy Questionnaire predicted lower 12-month OCBS-time (ß=-0.07 [95% CI, -0.12 to -0.03]; P=0.002) and OCBS-difficulty (ß=-0.09 [95% CI, -0.12 to -0.06]; P<0.001). CONCLUSIONS: Among survivors at 12 months, baseline and change in patient health status were associated with subsequent caregiver time on task and task difficulty in dyads receiving advanced heart failure surgical therapies, highlighting the potential for serial 12-item Kansas City Cardiomyopathy Questionnaire assessments to identify caregivers at risk of increased burden. REGISTRATION: URL: https://www.clinicaltrials.gov; unique identifier: NCT02568930.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Medidas de Resultados Relatados pelo Paciente , Humanos , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/psicologia , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Cuidadores/psicologia , Sobrecarga do Cuidador/psicologia , Nível de Saúde , Qualidade de Vida , Inquéritos e Questionários , Estados Unidos , Fatores de Tempo , Efeitos Psicossociais da Doença
5.
JACC Adv ; 3(5): 100916, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38939630

RESUMO

Background: Vasoplegia after cardiac surgery is associated with adverse outcomes. However, the clinical effects of vasoplegia and the significance of its duration after continuous-flow left ventricular assist device (CF-LVAD) implantation are less known. Objectives: This study aimed to identify predictors of and outcomes from transient vs prolonged vasoplegia after CF-LVAD implantation. Methods: The study was a retrospective review of consecutive patients who underwent CF-LVAD implantation between January 1, 2005, and December 31, 2017. Vasoplegia was defined as the presence of all of the following: mean arterial pressure ≤65 mm Hg, vasopressor (epinephrine, norepinephrine, vasopressin, or dopamine) use for >6 hours within the first 24 hours postoperatively, cardiac index ≥2.2 L/min/m2 and systemic vascular resistance <800 dyne/s/cm5, and vasodilatory shock not attributable to other causes. Prolonged vasoplegia was defined as that lasting 12 to 24 hours; transient vasoplegia was that lasting 6 to <12 hours. Patient characteristics, outcomes, and risk factors were analyzed. Results: Of the 600 patients who underwent CF-LVAD implantation during the study period, 182 (30.3%) developed vasoplegia. Mean patient age was similar between the vasoplegia and no-vasoplegia groups. Prolonged vasoplegia (n = 78; 13.0%), compared with transient vasoplegia (n = 104; 17.3%), was associated with greater 30-day mortality (16.7% vs 5.8%; P = 0.02). Risk factors for prolonged vasoplegia included preoperative dialysis and elevated body mass index. Conclusions: Compared with vasoplegia overall, prolonged vasoplegia was associated with worse survival after CF-LVAD implantation. Treatment to avoid or minimize progression to prolonged vasoplegia may be warranted.

7.
Circ Heart Fail ; 17(7): e011504, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38910562

RESUMO

BACKGROUND: The mechanism of cardiac reverse remodeling (CRR) mediated by the left ventricular assist device remains unclear. This study aims to identify the specific cell type responsible for CRR and develop the therapeutic target that promotes CRR. METHODS: The nuclei were extracted from the left ventricular tissue of 4 normal controls, 4 CRR patients, and 4 no cardiac reverse remodeling patients and then subjected to single-nucleus RNA sequencing for identifying key cell types responsible for CRR. Gene overexpression in transverse aortic constriction and dilated cardiomyopathy heart failure mouse model (C57BL/6J background) and pathological staining were performed to validate the results of single-nucleus RNA sequencing. RESULTS: Ten cell types were identified among 126 156 nuclei. Cardiomyocytes in CRR patients expressed higher levels of ATP5F1A than the other 2 groups. The macrophages in CRR patients expressed more anti-inflammatory genes and functioned in angiogenesis. Endothelial cells that elevated in no cardiac reverse remodeling patients were involved in the inflammatory response. Echocardiography showed that overexpressing ATP5F1A through cardiomyocyte-specific adeno-associated virus 9 demonstrated an ability to improve heart function and morphology. Pathological staining showed that overexpressing ATP5F1A could reduce fibrosis and cardiomyocyte size in the heart failure mouse model. CONCLUSIONS: The present results of single-nucleus RNA sequencing and heart failure mouse model indicated that ATP5F1A could mediate CRR and supported the development of therapeutics for overexpressing ATP5F1A in promoting CRR.


Assuntos
Modelos Animais de Doenças , Insuficiência Cardíaca , Camundongos Endogâmicos C57BL , Miócitos Cardíacos , Remodelação Ventricular , Miócitos Cardíacos/metabolismo , Miócitos Cardíacos/patologia , Animais , Humanos , Insuficiência Cardíaca/genética , Insuficiência Cardíaca/metabolismo , Insuficiência Cardíaca/fisiopatologia , Camundongos , Masculino , ATPases Mitocondriais Próton-Translocadoras/metabolismo , ATPases Mitocondriais Próton-Translocadoras/genética , Feminino , Pessoa de Meia-Idade
9.
Circulation ; 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38940005

RESUMO

BACKGROUND: Current estimates of atrial fibrillation (AF)-associated mortality rely on claims- or clinical-derived diagnoses of AF, limit AF to a binary entity, or are confounded by comorbidities. The objective of the present study is to assess the association between device-recognized AF and mortality among patients with cardiac implantable electronic devices capable of sensitive and continuous atrial arrhythmia detection. Secondary outcomes include relative mortality among cohorts with no AF, paroxysmal AF, persistent AF, and permanent AF. METHODS: Using the deidentified Optum Clinformatics US claims database (2015 to 2020) linked to the Medtronic CareLink database, we identified individuals with a cardiac implantable electronic device who transmitted data ≥6 months after implantation. AF burden was assessed during the first 6 months after implantation (baseline period). Subsequent mortality, assessed from claims data, was compared between patients with and those without AF, with adjustment for age, geographic region, insurance type, Charlson Comorbidity Index, and implantation year. RESULTS: Of 21 391 patients (age, 72.9±10.9 years; 56.3% male) analyzed, 7798 (36.5%) had device-recognized AF. During a mean of 22.4±12.9 months (median, 20.1 [12.8-29.7] months) of follow-up, the overall incidence of mortality was 13.5%. Patients with AF had higher adjusted all-cause mortality than patients without AF (hazard ratio, 1.29 [95% CI, 1.20-1.39]; P<0.001). Among those with AF, patients with nonparoxysmal AF had the greatest risk of mortality (persistent AF versus paroxysmal AF: hazard ratio, 1.36 [95% CI, 1.18-1.58]; P<.001; permanent AF versus paroxysmal AF: hazard ratio, 1.23 [95% CI, 1.14-1.34]; P<.001). CONCLUSIONS: After adjustment for potential confounding factors, presence of AF was associated with higher mortality than no AF in our cohort of patients with cardiac implantable electronic devices. Among those with AF, nonparoxysmal AF was associated with the greatest risk of mortality.

10.
Ann Gastroenterol ; 37(3): 313-320, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38779638

RESUMO

Background: Gastrointestinal bleeding (GIB) is a common complication after placement of a left ventricular assist device (LVAD). Some institutions attempt to mitigate post-LVAD GIB using preoperative endoscopy. Our study evaluated whether preoperative endoscopy was associated with a lower risk of post-LVAD GIB. Methods: This was a multicenter cohort study of patients who underwent LVAD insertion from 2010-2019 at 3 academic sites. A total of 398 study participants were categorized based on whether they underwent preoperative endoscopy or not. The follow-up period was 1 year and the primary outcome was GIB. Secondary outcomes were severe bleeding and intraprocedural complications. Results: A total of 114 patients experienced GIB within 1 year, with a higher rate in the endoscopy cohort (36.4% vs. 24.8%, P=0.015). After adjusting for covariables, the endoscopy cohort remained at increased risk of GIB (adjusted odds ratio 1.77, 95% confidence interval 1.05-2.976; P=0.032). Severe bleeding was common (47.4%). Arteriovenous malformations (48 cases) and peptic ulcer disease (17 cases) were the most identified sources of GIB. Only 1 minor adverse event occurred during preoperative endoscopy. Conclusions: Our study suggests that pre-LVAD endoscopy is associated with a higher risk of GIB post LVAD, despite controlling for confounders. While this was an observational study and may not have captured all confounders, it appears that endoscopic screening may not be warranted.

11.
Clin Case Rep ; 12(5): e8868, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38756618

RESUMO

Key Clinical Message: A patient presented with cardiogenic shock, requiring the implantation of a left ventricular assist device (LVAD), and acute myeloblastic leukemia. This necessitated total body irradiation (TBI) while balancing dose reduction to the LVAD components to avoid potential radiation damage. Here we outline our treatment approach and dose estimates to the LVAD. Abstract: This case report discusses the delivery of TBI to a patient with an LVAD. This treatment required radiation-dose determinations and consequential reductions for the heart, LVAD, and an external controller connected to the LVAD. The patient was treated using a traditional 16MV anterior posterior (AP)/posterior anterior (PA) technique at a source-to-surface-distance of 515 cm for 400 cGy in two fractions. A 3 cm thick Cerrobend block was placed on the beam spoiler to reduce dose to the heart and LVAD to 150 cGy. The external controller was placed in a 1 cm thick acrylic box to reduce neutron dose and positioned as far from the treatment fields as achievable. In vivo measurements were made using optically stimulated luminescence dosimeters (OSLDs) placed inside the box at distances of 2 cm, 8.5 cm, and 14 cm from the field edge, and on the patient along the central axis and centered behind the LVAD block. Further ion chamber measurements were made using a solid water phantom to more accurately estimate the dose delivered to the LVAD. Neutron dose measurements were also conducted. The total estimated dose to the controller ranged from 135.3 cGy to 91.5 cGy. The LVAD block reduced the surface dose to the patient to 271.6 cGy (68.1%). The block transmission factors of the 3 cm Cerrobend block measured in the phantom were 45% at 1 cm depth and decreased asymptotically to around 30% at 3 cm depth. Applying these transmission factors to the in vivo measurements yielded a dose of 120 cGy to the implanted device. The neutron dose the LVAD region is estimated around 0.46 cGy. Physical limitations of the controller made it impossible to completely avoid dose. Shielding is recommended. The block had limited dose reduction to the surface, due to secondary particles, but appropriately reduced the dose at 3 cm and beyond. More research on LVADs dose limits would be beneficial.

12.
Circ Heart Fail ; 17(5): e010904, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38602105

RESUMO

BACKGROUND: Heart transplant (HT) in recipients with left ventricular assist devices (LVADs) is associated with poor early post-HT outcomes, including primary graft dysfunction (PGD). As complicated heart explants in recipients with LVADs may produce longer ischemic times, innovations in donor heart preservation may yield improved post-HT outcomes. The SherpaPak Cardiac Transport System is an organ preservation technology that maintains donor heart temperatures between 4 °C and 8 °C, which may minimize ischemic and cold-induced graft injuries. This analysis sought to identify whether the use of SherpaPak versus traditional cold storage was associated with differential outcomes among patients with durable LVAD undergoing HT. METHODS: Global Utilization and Registry Database for Improved Heart Preservation-Heart (NCT04141605) is a multicenter registry assessing post-HT outcomes comparing 2 methods of donor heart preservation: SherpaPak versus traditional cold storage. A retrospective review of all patients with durable LVAD who underwent HT was performed. Outcomes assessed included rates of PGD, post-HT mechanical circulatory support use, and 30-day and 1-year survival. RESULTS: SherpaPak (n=149) and traditional cold storage (n=178) patients had similar baseline characteristics. SherpaPak use was associated with reduced PGD (adjusted odds ratio, 0.56 [95% CI, 0.32-0.99]; P=0.045) and severe PGD (adjusted odds ratio, 0.31 [95% CI, 0.13-0.75]; P=0.009), despite an increased total ischemic time in the SherpaPak group. Propensity matched analysis also noted a trend toward reduced intensive care unit (SherpaPak 7.5±6.4 days versus traditional cold storage 11.3±18.8 days; P=0.09) and hospital (SherpaPak 20.5±11.9 days versus traditional cold storage 28.7±37.0 days; P=0.06) lengths of stay. The 30-day and 1-year survival was similar between groups. CONCLUSIONS: SherpaPak use was associated with improved early post-HT outcomes among patients with LVAD undergoing HT. This innovation in preservation technology may be an option for HT candidates at increased risk for PGD. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04141605.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Preservação de Órgãos , Sistema de Registros , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Preservação de Órgãos/métodos , Estudos Retrospectivos , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/mortalidade , Resultado do Tratamento , Adulto , Idoso , Disfunção Primária do Enxerto , Fatores de Tempo
13.
Braz J Cardiovasc Surg ; 39(3): e20230258, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38630058

RESUMO

INTRODUCTION: Limited options in the end-stage treatment of heart failure have led to increased use of left ventricular assist devices. For this reason, the rate of non-cardiac surgeries in patients with left ventricular assist devices is also increasing. Our study aims to analyze surgical rate, anesthesia management, and results by reviewing our 11-year experience with patients who underwent non-cardiac surgery receiving left ventricular assist devices support. METHODS: We retrospectively evaluated 57 patients who underwent non-cardiac surgery and 67 non-cardiac surgical procedures among 274 patients who applied between January 2011 and December 2022 and underwent left ventricular assist devices implantation with end-stage heart failure. RESULTS: Fifty (74.6%) patients with left ventricular assist devices admitted to the hospital for non-cardiac surgery were emergency interventions. The most common reasons for admission were general surgery (52.2%), driveline wound revision (22.3%), and neurological surgery (14.9%). This patient group has the highest in-hospital mortality rate (12.8%) and the highest rate of neurological surgery (8.7%). While 70% of the patients who underwent neurosurgery were taken to surgery urgently, the International Normalized Ratio values of these patients were between 3.5 and 4.5 at the time of admission to the emergency department. CONCLUSION: With a perioperative multidisciplinary approach, higher morbidity and mortality risks can be reduced during emergencies and major surgical procedures.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Estudos Retrospectivos , Hospitais , Ventrículos do Coração , Insuficiência Cardíaca/cirurgia
14.
Nurs Open ; 11(3): e2102, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38530867

RESUMO

AIMS: To evaluate the validity and reliability of the self-care behaviour scale for patients with left ventricular assist devices. DESIGN: Methodological study. METHODS: The English version of the scale was translated into Korean, and it was then back-translated into English. Survey data were collected from 32 patients with left ventricular assist device in South Korea, and construct validity, content validity and reliability were analysed. RESULTS: The original self-care behaviour scale comprises three domains and 33 items, whereas the Korean self-care behaviour scale comprises 27 items and five domains: device management, wound management, symptom monitoring, activated healthcare system and self-care management. Cronbach's alpha for the overall scale was 0.94, and that for the five domains ranged from 0.36 to 0.90. The intraclass correlation coefficient for the overall scale was 0.89, and the five domains ranged from 0.71 to 0.88. CONCLUSION: The newly evaluated scale would be valid and reliable in measure self-care behaviour for patients with a left ventricular assist device. IMPLICATIONS FOR THE PROFESSION AND/OR PATIENT CARE: Patients can manage the left ventricular assist device on their own based on evidence and use it as a tool for effective communication with medical professionals.


Assuntos
Coração Auxiliar , Humanos , Autocuidado , Reprodutibilidade dos Testes , Inquéritos e Questionários , República da Coreia
15.
Acute Crit Care ; 39(1): 169-178, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38303584

RESUMO

BACKGROUND: Studies on the association between pleural effusion (PE) and left ventricular assist devices (LVADs) are limited. This study aimed to examine the characteristics and the clinical impact of PE following LVAD implantation. METHODS: This study is a prospective analysis of patients who underwent LVAD implantation from June 2015 to December 2022. We investigated the prognostic impact of therapeutic drainage (TD) on clinical outcomes. We also compared the characteristics and clinical outcomes between early and late PE and examined the factors related to the development of late PE. RESULTS: A total of 71 patients was analyzed. The TD group (n=45) had a longer ward stay (days; median [interquartile range]: 31.0 [23.0-46.0] vs. 21.0 [16.0-34.0], P=0.006) and total hospital stay (47.0 [36.0-82.0] vs. 31.0 [22.0-48.0], P=0.002) compared to the no TD group (n=26). Early PE was mostly exudate, left-sided, and neutrophil-dominant even though predominance of lymphocytes was the most common finding in late PE. Patients with late PE had a higher rate of reintubation within 14 days (31.8% vs. 4.1%, P=0.004) and longer hospital stays than those without late PE (67.0 [43.0-104.0] vs. 36.0 [28.0-48.0], P<0.001). Subgroup analysis indicated that female sex, low body mass index, cardiac resynchronization therapy, and hypoalbuminemia were associated with late PE. CONCLUSIONS: Compared to patients not undergoing TD, those undergoing TD had a longer hospital stay but not a higher 90-day mortality. Patients with late PE had poor clinical outcomes. Therefore, the correction of risk factors, like hypoalbuminemia, may be required.

16.
Heart Lung ; 64: 198-207, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38301417

RESUMO

BACKGROUND: Everyday living with a left ventricular assist device (LVAD) is complex, particularly for people with physical or cognitive impairments or limited social supports. There is a need for standardized pre-operative functional evaluations. OBJECTIVES: Our objectives were to describe a pre-operative occupational therapy (OT) evaluation for LVAD candidates, assess its feasibility in routine care, and characterize functional needs. METHODS: We retrospectively reviewed electronic medical records of pre-operative OT consultations for LVAD candidates over four years (n = 209). Occupational profile, vision, and sensation were operationalized from documentation narratives. Daily functioning was measured with Activity Measure for Post-Acute Care, grip strength with dynamometer, cognition with Montreal Cognitive Assessment and Allen Cognitive Level Screen-5, and LVAD self-management with a performance-based ordinal scale. RESULTS: 89.5 % of consultations were completed, averaging 61.2 min (n = 187): 79.1 % (148/187) inpatient and 20.9 % (39/187) outpatient. Patients completed 87.7 % (164/187) to 100.0 % (187/187) of evaluation components. 21.9 % (41/187) of candidates lived alone. 6.4 % (12/187) and 7.0 % (13/185) had visual and sensory dysfunction. 57.4 % were independent with daily activities (104/181). 17.7 % (32/181) had impaired grip strength. 69.3 % (124/179) had impaired cognition, 29.7 % (51/172) with impaired functional cognition for everyday activities. 88.4 % (145/164) required physical or cueing assistance while practicing LVAD batteries management. OTs interpreted that 20.9 % (39/187) would likely require 24/7 post-operative support with LVAD self-care. CONCLUSION: Pre-operative OT evaluations were feasible and emphasized complex functional needs. Assessing LVAD self-care abilities may inform candidacy and facilitate early interventions to optimize functioning. OT should be consulted within interprofessional teams for all LVAD candidates.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Terapia Ocupacional , Humanos , Insuficiência Cardíaca/terapia , Estudos Retrospectivos , Estudos de Viabilidade , Resultado do Tratamento
17.
Circulation ; 149(14): e1051-e1065, 2024 04 02.
Artigo em Inglês | MEDLINE | ID: mdl-38406869

RESUMO

Cardiogenic shock continues to portend poor outcomes, conferring short-term mortality rates of 30% to 50% despite recent scientific advances. Age is a nonmodifiable risk factor for mortality in patients with cardiogenic shock and is often considered in the decision-making process for eligibility for various therapies. Older adults have been largely excluded from analyses of therapeutic options in patients with cardiogenic shock. As a result, despite the association of advanced age with worse outcomes, focused strategies in the assessment and management of cardiogenic shock in this high-risk and growing population are lacking. Individual programs oftentimes develop upper age limits for various interventional strategies for their patients, including heart transplantation and durable left ventricular assist devices. However, age as a lone parameter should not be used to guide individual patient management decisions in cardiogenic shock. In the assessment of risk in older adults with cardiogenic shock, a comprehensive, interdisciplinary approach is central to developing best practices. In this American Heart Association scientific statement, we aim to summarize our contemporary understanding of the epidemiology, risk assessment, and in-hospital approach to management of cardiogenic shock, with a unique focus on older adults.


Assuntos
Transplante de Coração , Coração Auxiliar , Humanos , Idoso , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/epidemiologia , Choque Cardiogênico/terapia , American Heart Association , Resultado do Tratamento
18.
Circ Cardiovasc Interv ; 17(3): e013367, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38410944

RESUMO

INTRODUCTION: Percutaneous coronary intervention for complex coronary disease is associated with a high risk of cardiogenic shock. This can cause harm and limit the quality of revascularization achieved, especially when left ventricular function is impaired at the outset. Elective percutaneous left ventricular unloading is increasingly used to mitigate adverse events in patients undergoing high-risk percutaneous coronary intervention, but this strategy has fiscal and clinical costs and is not supported by robust evidence. METHODS: CHIP-BCIS3 (Controlled Trial of High-Risk Coronary Intervention With Percutaneous Left Ventricular Unloading) is a prospective, multicenter, open-label randomized controlled trial that aims to determine whether a strategy of elective percutaneous left ventricular unloading is superior to standard care (no planned mechanical circulatory support) in patients undergoing nonemergent high-risk percutaneous coronary intervention. Patients are eligible for recruitment if they have severe left ventricular systolic dysfunction, extensive coronary artery disease, and are due to undergo complex percutaneous coronary intervention (to the left main stem with calcium modification or to a chronic total occlusion with a retrograde approach). Cardiogenic shock and acute ST-segment-elevation myocardial infarction are exclusions. The primary outcome is a hierarchical composite of all-cause death, stroke, spontaneous myocardial infarction, cardiovascular hospitalization, and periprocedural myocardial infarction, analyzed using the win ratio. Secondary outcomes include completeness of revascularization, major bleeding, vascular complications, health economic analyses, and health-related quality of life. A sample size of 250 patients will have in excess of 80% power to detect a hazard ratio of 0.62 at a minimum of 12 months, assuming 150 patients experience an event across all follow-up. CONCLUSIONS: To date, 169 patients have been recruited from 21 National Health Service hospitals in the United Kingdom, with recruitment expected to complete in 2024. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT05003817.


Assuntos
Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Qualidade de Vida , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/terapia , Choque Cardiogênico/etiologia , Medicina Estatal , Resultado do Tratamento , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Multicêntricos como Assunto
19.
J Chest Surg ; 57(3): 315-318, 2024 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-38225828

RESUMO

The HeartWare Ventricular Assist Device (HVAD) was widely used for mechanical circulatory support in patients with end-stage heart failure. However, there have been reports of a critical issue with HVAD pumps failing to restart, or experiencing delays in restarting, after being stopped. This case report describes 2 instances of HVAD failure-to-restart during heart transplantation surgery and routine outpatient care. Despite multiple attempts to restart the pump using various controllers and extensions, the HVAD failed to restart, triggering a hazard alarm for pump stoppage. In one case, the patient survived after receiving a heart transplantation, while in the other, the patient died immediately following the controller exchange. These cases highlight the rare but life-threatening complication of HVAD failure-to-restart, underscoring the importance of awareness among clinicians, patients, and caregivers, and adherence to the manufacturer's guidelines and recommendations for HVAD management.

20.
Korean J Anesthesiol ; 77(2): 175-184, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36912004

RESUMO

With the growing number of patients undergoing left ventricular assist device (LVAD) implantation and improved survival in this population, more patients with LVADs are presenting for various types of non-cardiac surgery. Therefore, anesthesiologists need to understand the physiology and adequately prepare for the perioperative management of this unique patient population. This review addresses perioperative considerations and intraoperative management for the safe and successful management of patients with an LVAD undergoing non-cardiac surgery. Understanding the basic physiology of preload dependency and afterload sensitivity in these patients is essential. The main considerations include a collaborative preoperative multidisciplinary approach, perioperative care aimed at optimizing the intravascular volume and right ventricular function, and maintaining the afterload within recommended ranges for optimal LVAD function.


Assuntos
Anestésicos , Coração Auxiliar , Procedimentos Cirúrgicos Torácicos , Humanos , Assistência Perioperatória , Anestesiologistas
SELEÇÃO DE REFERÊNCIAS