Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 79
Filtrar
1.
Lab Med ; 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38801245

RESUMO

BACKGROUND: Glycated hemoglobin, or hemoglobin A1c (HbA1c), serves as a crucial marker for diagnosing diabetes and monitoring its progression. We aimed to assess the interference posed by common Hb variants on popular HbA1c measurement systems. METHODS: A total of 63 variant and nonvariant samples with target values assigned by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) reference method were included. We assessed 6 methods for measuring HbA1c in the presence of HbS, HbC, HbD, HbE, and fetal hemoglobin (HbF): 2 cation-exchange high-performance liquid chromatography (HPLC) methods (Bio-Rad D-100 and HLC-723 G8), a capillary electrophoresis (CE) method (Sebia Capillarys 3 TERA), an immunoassay (Roche c501), an enzyme assay system (Mindray BS-600M), and a boronate affinity method (Primus Premier Hb9210). RESULTS: The HbA1c results for nonvariant samples from the 6 methods were in good agreement with the IFCC reference method results. The Bio-Rad D-100, Capillarys 3, Mindray BS-600M, Premier Hb9210, and Roche c501 showed no interference from HbS, HbC, HbD, and HbE. Clinically significant interference was observed for the HLC-723 G8 standard mode. Elevated HbF levels caused significant negative biases for all 6 methods, which increased with increasing HbF concentration. CONCLUSION: Elevated levels of HbF can severely affect HbA1c measurements by borate affinity, immunoassays, and enzyme assays.

2.
Pract Lab Med ; 39: e00379, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38715657

RESUMO

Background: Hemoglobin A1c has been widely used to diagnose and monitor diabetes. However, the accuracy of HbA1c analysis can be significantly affected by hemoglobin variants, leading to falsely low or elevated levels and misdiagnosis or inappropriate diabetes management. Case report: In this study, we present the case of a 23-year-old man with undetectable HbA1c levels during his annual checkup by high-performance liquid chromatography (HPLC) and capillary electrophoresis (CE). To investigate the reason for HbA1c absence, Sanger sequencing, multiplex ligation-dependent probe amplification assay (MLPA), long-read single molecule real-time sequencing (SMRT) and MALDI-TOF mass spectrometry (MS) were performed, and the proband was identified as compound heterozygous of ß-thalassemia with Hb G-Taipei (HBB:c.68A > G) and Hb Lepore-Boston-Washington (NG_000007.3:g.63632_71046del). Conclusion: The combination of these molecular technologies including MLPA, long-read SMRT sequencing and MALDI-TOF MS is beneficial for identifying rare hemoglobin variants. This case also provides essential evidence for uncovering the effect of compound heterozygosity for Hb Lepore-Boston-Washington and Hb G-Taipei on hematological phenotypes and HbA1c analysis.

3.
Hematology ; 29(1): 2339559, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38626234

RESUMO

OBJECTIVES: In clinical practice, the majority of α-thalassaemia cases arise from deletions of the α-globin genes. However, a subset of cases is attributed to rare haemoglobin variants, which can manifest with borderline or normal screening results, potentially leading to missed diagnoses in clinical practice. METHODS: Blood samples were collected from family members and underwent haematological, DNA and RNA analysis. RESULTS: The five-month-old proband presented a haematological phenotype consistent with Hb H disease. The mother's haematology profile was consistent with an α-thalassaemia carrier, while the father exhibited a borderline reduction in MCV and MCH. MALDI-TOF identified an abnormal α-chain in the proband. DNA analysis revealed a novel α-globin variant (HBA2:c.175C>A, α58His>Asn, Hb DG-Nancheng) affecting the distal histidine in the family. The father and the mother had α-genotype of --SEA/αα and αDG-Nanchengα/αα, respectively; while the proband inherited both mutant alleles (--SEA/αDG-Nanchengα). Sequencing of cDNA from HBA2 gene identified an equal ratio of normal and mutant alleles. CONCLUSION: This rare case highlighted the importance of identifying rare haemoglobin variant during prenatal screening. The clinical and genetic data provides useful information on the pathogenicity of this variant and further insight into the role of distal histidine residue of α-globin.


Assuntos
Hemoglobinas Anormais , Talassemia alfa , Feminino , Humanos , Lactente , Gravidez , alfa-Globinas/genética , Talassemia alfa/diagnóstico , Talassemia alfa/genética , China , Hemoglobinas Anormais/genética , Histidina/genética , Mutação
4.
Hemoglobin ; 48(2): 79-86, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38565203

RESUMO

Hemoglobin (Hb) Volga is a rare, unstable ß-chain hemoglobin variant (ß27 Ala→Asp), causing chronic hemolytic anemia. This study presents two members of a Danish family, splenectomized due to Hb Volga at and with multiple thrombotic events. The proband was diagnosed with Hb Volga 9 years old and splenectomy was performed as a part of treatment. Throughout his life, he experienced multiple superficial thrombophlebitis, two episodes of distal deep venous thrombosis (DVT) on lower extremities (age 32 and 33) and a transient ischemic attack (TIA) presented as amaurosis fugax (age 51). Thrombophilia investigation was normal. The proband's son was diagnosed with Hb Volga and underwent splenectomy at the age of 6. Despite anticoagulation therapy, he suffered from multiple venous thromboembolic events in his youth and died of chronic pulmonary embolism (PE)/pulmonary hypertension combined with infection. Given the observed propensity for multiple thromboses in these two patients, a literature review was conducted investigating reported occurrence of thrombotic events in individuals with Hb Volga.Currently 25 cases of Hb Volga are reported worldwide. The clinical symptoms primarily described are related to hemolytic anemia. Splenectomy is reported in 15 patients. Thromboses have previously been reported in only three patients who were also splenectomized. These cases involved DVT and PE, myocardial infarction, and an unspecified thrombotic event. The proband represents the first reported Hb Volga case with both venous and arterial thrombotic disorders. The exact mechanism underlying thrombotic tendency in patients with Hb Volga remains unknown, but it is probably associated with splenectomy.


Assuntos
Hemoglobinas Anormais , Esplenectomia , Humanos , Esplenectomia/efeitos adversos , Masculino , Hemoglobinas Anormais/genética , Adulto , Trombose/etiologia , Trombose/diagnóstico , Pessoa de Meia-Idade , Dinamarca/epidemiologia , Trombose Venosa/etiologia , Trombose Venosa/diagnóstico , Criança , Linhagem
5.
Diabetol Int ; 15(2): 302-306, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38524927

RESUMO

Hemoglobin variants are often discovered when hemoglobin A1c (HbA1c) levels measured with a high-performance liquid chromatography (HPLC) system in fast mode are found to be low. The HA-8180V HPLC analyzer by Arkray offers two measurement modes: fast mode (FM) and variant mode (VM). Two Japanese patients with α-chain variant Hb Q-Iran detected incidentally after analyses with the HA-8180V in VM showed an abnormal peak, are presented. The first patient was a man in his 70 s, and the second patient was a man in his 50 s. Both were non-diabetic, but their results from HbA1c measurement in VM showed an abnormal peak. The VM-HbA1c, FM-HbA1c, and HbA1c measured by enzymatic assay and glycated albumin levels of the two patients were all within the reference ranges. They were diagnosed as having Hb Q-Iran (α2-75Asp → His) by globin gene analysis. It is difficult to detect α-chain hemoglobin variants based on abnormal FM-HbA1c levels, but measuring HbA1c in VM is useful for efficiently detecting hemoglobin variants.

6.
Lab Med ; 55(4): 528-533, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38253465

RESUMO

We present 3 cases of discordant results from screening hemoglobin A1c (HbA1c) measured by ion-exchange high-performance liquid chromatography (HPLC) all due to various forms of interference and flagged by the instrument as "suspected hemoglobin E (HbE)." The first case was due to a rare hemoglobin variant, later confirmed to be hemoglobin Hoshida, the second due to "true" heterozygous HbE, and the third a result of analytical artifact causing splitting of the HbA1c peak without an underlying variant hemoglobin. We examine the similarities in these cases along with the laboratory work-up to classify each cause of interference to demonstrate the wide array of potential causes for the suspected HbE flag and why it warrants proper work-up. Because there is no standardized method of reporting out hemoglobin variant interference in HbA1c measurement, we discuss our laboratory's process of investigating discordant HbA1c measurements and reporting results in cases with variant interference as 1 possible model to follow, along with discussing the associated laboratory, ethical, and clinical considerations. We also examine the structure of hemoglobin Hoshida, HbE, and conduct a brief literature review of previous reports.


Assuntos
Hemoglobinas Glicadas , Hemoglobina E , Humanos , Hemoglobinas Glicadas/análise , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia por Troca Iônica/métodos , Hemoglobina E/análise , Hemoglobina E/genética , Masculino , Feminino , Pessoa de Meia-Idade , Adulto
7.
Pract Lab Med ; 38: e00346, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38099267

RESUMO

Objectives: High-performance liquid chromatography (HPLC) is commonly used to measure hemoglobin A1c (HbA1c) levels and detect hemoglobin variants (Hb-Vars). HLC-723GR01 (GR01) is a new-generation automated ion-exchange HPLC system with two switchable analysis modes, namely short (30 s/test) and long modes (50 s/test). We evaluated the general performance of both analysis modes of GR01 for quantifying HbA1c and detecting Hb-Vars. Design and methods: We evaluated the instrument's precision based on CLSI protocol EP-05-A3. A comparison of the two analysis modes of GR01 against the standard mode of HLC-723G11 was performed on 100 whole blood samples. The GR01 long mode was compared with affinity HPLC (AF-HPLC) for detecting common Hb-Vars (HbE, HbD, HbS, and HbC, >20 samples). To examine the detection capability for minor Hb-Vars, we analyzed 26 Hb-Vars using multiple analyzers, including both analysis modes of GR01. Results: Both modes of GR01 had within-laboratory coefficients of variation of ≤1.0 % from four samples with HbA1c concentrations of 32-86 mmol/mol. Good correlation was observed between GR01 and HLC-723G11. The results for HbA1c detection in the presence of the major variants revealed a strong correlation between the long mode of GR01 and AF-HPLC (r = 0.986-0.998), and the difference biases ranged 0.1-1.9 mmol/mol. In the long mode, only one variant had a difference bias exceeding 14 % [10 % (%NGSP)]. Conclusion: The two analysis modes of GR01 were fast and had high accuracy and reproducibility, indicating their utility for routine clinical use in measuring HbA1c samples with Hb-Vars.

8.
BMC Pediatr ; 23(1): 639, 2023 12 18.
Artigo em Inglês | MEDLINE | ID: mdl-38110882

RESUMO

BACKGROUND: Hemoglobin (Hb) Chile [ß28(B10) Leu > Met; HBB: c.85 C > A] is a rare hemoglobin variant caused by a missense mutation in the HBB gene. Only one case of Hb Chile has been reported worldwide so far. It is an unstable hemoglobin, characterized by cyanosis associated with chronic methemoglobinemia and hemolytic anemia induced by sulfonamides or methylene blue. CASE PRESENTATION: A 9-year-3-month-old girl had mild anemia of unknown etiology for more than 6 years. She had a slight pallor without other symptoms or signs. The complete blood count revealed normocytic normochromic anemia with a sometimes-elevated reticulocyte count, and the bone marrow cytology showed marked erythroid hyperplasia, but the tests related to hemolysis were normal. Therefore, the whole exome sequencing was performed and showed a heterozygous mutation for HBB: c.85 C > A. With asymptomatic methemoglobinemia confirmed later, she was eventually diagnosed with Hb Chile. CONCLUSIONS: This is the first report of Hb Chile in China and the second worldwide. This case shows that Hb Chile is clinically heterogeneous and difficult to diagnose and expands our understanding on the clinical and hematological traits of the disease.


Assuntos
Anemia Hemolítica , Hemoglobinas Anormais , Metemoglobinemia , Feminino , Humanos , Lactente , Metemoglobinemia/diagnóstico , Metemoglobinemia/genética , Hemoglobinas Anormais/genética , Anemia Hemolítica/diagnóstico , Anemia Hemolítica/genética , China
9.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 54(5): 1019-1023, 2023 Sep.
Artigo em Chinês | MEDLINE | ID: mdl-37866962

RESUMO

Objective: To examine the common types of hemoglobin variants and to evaluate the influence of common variants on the results of two kinds of glycosylated hemoglobin (HbA1c) tests. Methods: We conducted a retrospective study, analyzing the data of a patient population undergoing two HbA1c tests, high performance liquid chromatography (HPLC) and capillary electrophoresis (CE), at West China Hospital, Sichuan University between March 2021 and February 2022. By screening the chromatograms, the hemoglobin variants were identified and their migration positions in the CE method were recorded. The effects of the variants with different migration positions on the findings of the two methods were compared. Variant samples with different migration positions were selected and Sanger sequencing was performed to determine mutations in HBA1, HBA2, and HBB genes in the variant samples. Results: We examined the HbA1c of 207 786 patient samples, identifying variant peaks in the chromatograms of 372 patients. The detection rate of variants was 0.18%, with the variant identification rate of HPLC being 43.3% and that of CE, 100%. Through sequencing, 20 variants were detected. A total of 261 patient samples were tested for HbA1c with both HPLC and CE. HPLC reported all HbA1c results, while CE did not report HbA1c results for 28 samples, among which, 26 showed abnormal peaks that overlapped with HbA1c peaks, and 2 showed abnormal peaks that overlapped with HbA0 peaks. The commonly observed variant migration positions, as revealed by CE, were at the horizontal coordinates of 225±1, 200±3, 100±2, 124±1, 70±2, and 182±1. There was significant difference between HPLC method and CE method in the determination of HbA1c ( P<0.0083), and the difference between the two methods was the largest when there were variants in the 200±3 region. Linear regression showed that the correlation of HbA1c results between the two methods was different when different regional variants were present, and that the correlation between the two methods was strongest when 124±1 region was present ( r=0.998). Conclusion: There are diverse types of hemoglobin variants and most of them can affect the HbA1c findings of HPLC. Analyzing the chromatogram facilitates the identification of the variants.


Assuntos
Eletroforese Capilar , Humanos , Hemoglobinas Glicadas , Estudos Retrospectivos , Mutação , Eletroforese Capilar/métodos , Cromatografia Líquida de Alta Pressão/métodos
10.
Hemoglobin ; 47(4): 140-144, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37752804

RESUMO

We present a new hemoglobin variant, Hb Raklev, characterized by the substitution of leucine with glutamine at position 75 in the ß-globin chain. This variant was discovered inadvertently during an HbA1c evaluation using high performance liquid chromatography in a symptomless 54-year-old Caucasian woman, with the same variant also identified in her 16-year-old daughter. Purification of the hemoglobin revealed possibly diminished 2,3-bisphosphoglycerate (2,3-BPG) sensitivity, which may result in heightened oxygen affinity. Notably, two variants have been previously documented at this location: the unstable Hb Atlanta and the high-affinity Hb Pasadena.


Assuntos
Hemoglobinas Anormais , Globinas beta , Feminino , Humanos , Pessoa de Meia-Idade , Adolescente , Globinas beta/genética , Globinas beta/química , Leucina , Glutamina , Hemoglobinas Anormais/genética , Hemoglobinas Anormais/química , Cromatografia Líquida de Alta Pressão
11.
Hemoglobin ; 47(4): 137-139, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37605549

RESUMO

Hemoglobin (Hb) Hammersmith, formed by serine substitution for phenylalanine at residue 42 in the beta-globin chain, is a very rare variant of unstable hemoglobin with low oxygen affinity. For patients with hemoglobinopathies, it is well-established that hematopoietic stem cell transplantation provides a complete cure, but the literature on its role for those with Hb Hammersmith is limited. A seven-month-old girl who was examined for anemia and splenomegaly was followed up for congenital hemolytic anemia. The patient with visible cyanosis of the lips and whose p50 was low in blood gas was diagnosed with Hb Hammersmith through the DNA sequence analysis. During the follow-up, frequent blood transfusions had to be given due to anemia aggravated by infections. Following a successful hematopoietic stem cell transplant from an HLA-matched sibling, the patient completely recovered from Hb Hammersmith. The case is presented because of its rarity.


Assuntos
Anemia Hemolítica , Transplante de Células-Tronco Hematopoéticas , Hemoglobinopatias , Hemoglobinas Anormais , Feminino , Humanos , Criança , Lactente , Anemia Hemolítica/genética , Hemoglobinas Anormais/genética , Hemoglobinas Anormais/análise , Hemoglobinopatias/genética , Hemoglobinopatias/terapia , Hemoglobinopatias/diagnóstico
12.
Int J Lab Hematol ; 45(6): 961-968, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37605839

RESUMO

INTRODUCTION: Mutations in the hemoglobin subunit delta (HBD) gene (MIM#142000) are associated with decreased levels of the Hemoglobin A2 (Hb A2 ) fraction. We aimed to examine the prevalence of HBD gene mutations and summarize their characteristics in the Chinese population. METHODS: Individuals who exhibited Hb A2 levels below 1.8%, with or without Hb A2 variant peaks, were chosen for further investigation. Hemoglobin analysis was conducted using capillary electrophoresis. Common α and ß-thalassemia in China were detected using gap-PCR and reverse dot blot hybridization. The presence of HBD gene mutations was confirmed by DNA sequencing. RESULTS: A total of 188 patients were identified as carriers of the HBD gene mutation, with a prevalence of approximately 0.46%. We discovered 36 types of mutations, 30 of which resulted in δ-globin variants, while the remaining 6 resulted in δ-thalassemia. The most common mutation was HBD:c.-127 T > C, accounting for 87.2% of δ-thalassemia cases. In addition, we identified 11 novel HBD gene mutations and found 10 cases compounded with other common thalassemias. CONCLUSION: We observed a high prevalence of HBD gene mutations in southern China. Our findings provide a genetic basis for screening for δ-thalassemia and enrich the spectrum of HBD gene mutations.


Assuntos
Hemoglobinas Anormais , Talassemia beta , Talassemia delta , Humanos , Talassemia beta/epidemiologia , Talassemia beta/genética , Talassemia beta/diagnóstico , Talassemia delta/diagnóstico , Talassemia delta/epidemiologia , Talassemia delta/genética , População do Leste Asiático , Hemoglobina A2/genética , Hemoglobinas Anormais/genética , Mutação
13.
Health Sci Rep ; 6(7): e1270, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37465239

RESUMO

Background and Aims: Mobility and migration flows are growing from different countries of the world to European countries, including France and in particular the Mediterranean basin. This study aimed to investigate the presence of hemoglobin (Hb) variants in outpatients/inpatients of the Montpellier Hospital (France) in whom an HbA1c assay had been performed and for which the country of birth had been informed. Methods: This is a retrospective study from January 2016 to December 2020 based on all high-performance liquid chromatography (HPLC) chromatograms (Tosoh Bioscience HLC-723G8) having an alarm of suspected Hb variant during HbA1c measurement. The corresponding samples were systematically sent to the hematology laboratory for confirmation and identification of Hb variant. Patient's medical history, clinical and demographic data were extracted from each medical chart. Statistical analyses were performed using XLSTAT® software, version 2016.06.35661. Results: Three hundred sixty-three patients were confirmed with Hb variant exhibiting 17 different Hb profiles, highlighting the pivotal role of glycated hemoglobin (HbA1c) as a detection step. The prevalence of Hb variant in this southern French population was 0.71%, with the highest frequency for the beta-globin variants (n = 342/363; i.e., 94.2%), including the most common: S, C, E, and D in 200/342 (58.5%), 83/342 (24.3%), 29/342 (8.5%), and 11/342 (3.2%), respectively. Among patients with Hb variants, almost half (165/363; i.e., 45.4%) were born in the African continent with a predominance for Morocco (32/165; i.e., 19.3%) and Algeria (29/165; i.e., 17.5%). Conclusion: HbA1c assay is a useful tool to detect Hb variants. Hemoglobinopathies are a public health issue in the current French population which is a multiethnic society. Despite the monocentric nature of our study, we note a high frequency of Hb variants in the south of France, which underlines the importance of screening for Hb variants in the whole population.

15.
Clin Biochem ; 118: 110589, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37236295

RESUMO

BACKGROUND: Hemoglobinopathies include thalassemia syndromes, where production of one or more globin subunits of hemoglobin (Hb) is reduced, and structural Hb variants. Over 1000 disorders of Hb synthesis and/or structure have been identified and characterized, with phenotypes ranging from having severe clinical manifestations to clinically silent. Various analytical methods are used to phenotypically detect Hb variants. However, molecular genetic analysis is a more definitive method for Hb variant identification. CASE REPORT: Here, we report a case of a 23-month-old male with results from capillary electrophoresis, gel electrophoresis (acid and alkaline), and high-performance liquid chromatography most consistent with HbS trait. Specifically, capillary electrophoresis showed slightly elevated HbF and HbA2, HbA of 39.4% and HbS of 48.5%. The HbS percentage was consistently higher than expected (typically 30-40%) for HbS trait with no concurrent thalassemic indices. The patient has not experienced any clinical complications due to the hemoglobinopathy and he is thriving. CONCLUSION: Molecular genetic analysis revealed the presence of compound heterozygosity for HbS and Hb Olupona. Hb Olupona is an extremely rare beta-chain variant that appears as HbA on all three common methods used for phenotypic Hb analysis. When the fractional concentration of Hb variants is unusual, more definitive methods should be used, such as mass spectrometry or molecular genetic testing. In this case, incorrectly reporting this result as HbS trait is unlikely to have a significant clinical impact, as current evidence suggests Hb Olupona is not a clinically significant variant.


Assuntos
Hemoglobinopatias , Hemoglobinas Anormais , Talassemia , Masculino , Humanos , Hemoglobinas Anormais/genética , Hemoglobinopatias/diagnóstico , Hemoglobinopatias/genética , Talassemia/genética , Hemoglobina A2 , Eletroforese Capilar/métodos
16.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 54(3): 659-662, 2023 May.
Artigo em Chinês | MEDLINE | ID: mdl-37248601

RESUMO

Hemoglobin (Hb) variants are common factors that affect the results of glycosylated hemoglobin (A1C) tests. Hemoglobin variants react differently to different testing methods. Herein, we presented the first ever report of the effect of hemoglobin C (Hb C) on the test results of A1C in the Chinese population. High performance liquid chromatography (HPLC) and capillary electrophoresis were performed to measure A1C. Hemoglobin electrophoresis was conducted to identify the hemoglobin variants. Hb sequencing was performed to determine the mutation sites on the ß chain. HPLC showed decreased A1C results, which could be corrected by electrophoresis, but the electrophoresis graph still showed abnormal peaks. The hemoglobin electrophoresis results suggested that there were hemoglobin variants, which hemoglobin sequencing results revealed to be Hb C. Uncommon variations in a specific population tend to be overlooked. To avoid clinical decision-making being affected by the results of a single test, we recommend that an explanatory reporting model be routinely adopted for A1C tests so that all reports always contain explanatory notes for the testing methodology and analysis of the graphs.


Assuntos
Hemoglobina C , Hemoglobinas Anormais , Humanos , Hemoglobina C/análise , Hemoglobina C/genética , Hemoglobinas Glicadas , Hemoglobinas Anormais/genética , Hemoglobinas Anormais/análise , Mutação , Eletroforese Capilar , Cromatografia Líquida de Alta Pressão/métodos
17.
Hemoglobin ; 47(2): 97-101, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37194736

RESUMO

We identified a novel abnormal hemoglobin variant caused by a frameshift mutation at nucleotide position 396 in exon 3 of the ß-globin gene (HBB): NM_000518:c.396delG. This variant causes an emergence of alternative amino acid sequence starting at codon 133 and a new stop codon formed in the 3' untranslated region (3'UTR) of the HBB gene at amino acid position 158. This ß-globin gene variant was identified in a woman with a long history of hemolytic anemia. We named this variant Hb Ryazan after the proband's city of origin.


Assuntos
Anemia Hemolítica , Hemoglobinas Anormais , Feminino , Humanos , Anemia Hemolítica/genética , Globinas beta/genética , Globinas beta/química , Códon de Terminação , Éxons , Mutação da Fase de Leitura , Hemoglobinas Anormais/genética , Hemoglobinas Anormais/química , Mutação
18.
Hematology ; 28(1): 2184118, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-36867091

RESUMO

OBJECTIVE: In the present study, two unrelated cases of Hb Q-Thailand heterozygosity unlinked with the (-α4.2/) α+-thalassemia deletion allele were identified by long-read single molecule real-time (SMRT) sequencing in southern China. The aim of this study was to report the hematological and molecular features as well as diagnostic aspects of the rare manifestation. METHODS: Hematological parameters and hemoglobin analysis results were recorded. A suspension array system for routine thalassemia genetic analysis and long-read SMRT sequencing were applied in parallel for thalassemia genotyping. Traditional methods, including Sanger sequencing, multiplex gap-polymerase chain reaction (gap-PCR) and multiplex ligation-dependent probe amplification (MLPA), were used together to confirm the thalassemia variants. RESULTS: Long-read SMRT sequencing was used to diagnose two Hb Q-Thailand heterozygous patients for whom the hemoglobin variant was unlinked to the (-α4.2/) allele for the first time. The hitherto undescribed genotypes were verified by traditional methods. Hematological parameters were compared with those of Hb Q-Thailand heterozygosity linked with the (-α4.2/) deletion allele in our study. For the positive control samples, long-read SMRT sequencing revealed a linkage relationship between the Hb Q-Thailand allele and the (-α4.2/) deletion allele. CONCLUSIONS: Identification of the two patients confirms that the linkage relationship between the Hb Q-Thailand allele and the (-α4.2/) deletion allele is a common possibility but not a certainty. Remarkably, as it is superior to traditional methods, SMRT technology may eventually serve as a more comprehensive and precise method that holds promising prospects in clinical practice, especially for rare variants.


Assuntos
Hemoglobinas Anormais , Talassemia alfa , Humanos , Alelos , Heterozigoto
19.
Hematology ; 28(1): 2187154, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36939273

RESUMO

BACKGROUND: Hb Chapel Hill [Alpha2 74(EF3) Asp > Gly] results from an GAC > GGC substitution at codon 74 of the HBA1 or HBA2 genes. Hb Chapel Hill has not been reported since 1986. METHODS: A heterozygous mutation, HBA2: c.224A > G, was identified in the proband, her father and sister. We compared the haematological and clinical data of this family with the data reported in the limited number of individuals. RESULTS: Having excluded iron deficiency, the Hb Chapel Hill was asymptomatic in heterozygous state. The cases presented here characterize cases in new techniques including capillary electrophoresis (CE). Two aberrant peaks were identified by CE, a major peak migrating in the zone 7 that correspond to Hb Chapel Hill (αChapel Hill 2ß2) and a minor peak migrating in the zone 1 that correspond to Hb Chapel Hill2 (αChapel Hill 2δ2). Focusing on the variant expression, the Hb Chapel Hill plus Hb A2 variant were around 18.9-20.6% of total Hb in three members. CONCLUSION: This data will be useful for providing up-to-date and high quality information on the Hb Chapel Hill.


Assuntos
Hemoglobinas Anormais , Talassemia alfa , Feminino , Humanos , alfa-Globinas/genética , Talassemia alfa/genética , População do Leste Asiático , Hemoglobinas Anormais/genética , Hemoglobinas Anormais/metabolismo , Heterozigoto , Mutação , Masculino
20.
Hematology ; 28(1): 2188651, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36995301

RESUMO

OBJECTIVE: To investigate the molecular diagnosis of hemoglobin variants in Z region by Capillary electrophoresis in Central Guangxi, Southern China, and analyze their distribution and phenotypic characteristics, to provide a reference for clinical consultation and prenatal diagnosis for couples. METHODS: A total of 23,709 subjects were collected for blood routine analysis, hemoglobin analysis, and common α- and ß-globin gene loci in Chinese population. The hemoglobin electrophoresis components were divided into Zone 1-Zone 15 (Z1-Z15) by Capillary zone electrophoresis (CE). For samples not clearly detected by the conventional technology, Sanger sequencing, and multiplex ligation-dependent probe amplification (MLPA) were used. Single-molecule real-time (SMRT) sequencing technology was used to analyze rare-type genes in a sample with a structural variation. RESULTS: Ten rare hemoglobin variants distributed in Z region were detected in 23,709 samples, including Hb Cibeles, which was reported for the first time in Asia; Hb J-Broussais, Hb G-Honolulu and J-Wenchang-Wuming, they were first reported in Guangxi; 1 case of Hb Anti-Lepore Liuzhou, which was a newly discovered hemoglobin variant; hemoglobin variants Hb G-Siriraj, Hb Handsworth, Hb Q-Thailand, Hb Ube-2, Hb NewYork were also detected. CONCLUSION: There are a few studies on rare hemoglobin variants in Z region in Southern China. Ten rare hemoglobin variants were found in this study. The hematological phenotype and component content of hemoglobin variants are related to the occurrence of thalassemia. This study enriched the data of rare hemoglobin variants in Southern China and provided a comprehensive data basis for prenatal diagnosis of hemoglobin variants in this area.


Assuntos
Hemoglobinas Anormais , Talassemia , Humanos , China/epidemiologia , Hemoglobinas Anormais/genética , Hemoglobinas Anormais/análise , Fenótipo , Povo Asiático
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...