Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.385
Filtrar
1.
Inn Med (Heidelb) ; 65(8): 770-777, 2024 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-39007961

RESUMO

Atrial fibrillation represents the most frequent persistent cardiac arrhythmia and is associated with an increased morbidity and mortality. An important component of the holistic treatment of atrial fibrillation is oral anticoagulation (OAC) for the prevention of stroke. The CHA2DS2-VASc score as a risk score is recommended for estimation of the individual stroke risk and the concomitant need of OAC in these patients. In the majority of patients the OAC is nowadays carried out with direct oral anticoagulants (DOAC), which have proved to be effective with a moderate side effect profile and have replaced vitamin K antagonists as the standard substance. In the meantime, these principles have become established as the usual practice but some issues regarding OAC in patients with atrial fibrillation are still insufficiently answered. Furthermore, it is unclear whether OACs need to be continued after successful treatment of atrial fibrillation with pulmonary vein ablation or in some cases can even be discontinued. Unanswered questions also remain regarding the treatment of subclinical atrial fibrillation and atrial high-frequency episodes detected by implanted heart rhythm devices. Especially the duration of atrial high-frequency episodes that should trigger the initiation of OAC treatment is still under debate. Therefore, currently the benefits of stroke prevention must be carefully weighed up against the risk of bleeding complications.


Assuntos
Anticoagulantes , Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Anticoagulantes/uso terapêutico , Anticoagulantes/administração & dosagem , Anticoagulantes/efeitos adversos , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/complicações , Administração Oral , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/etiologia , Hemorragia/induzido quimicamente
2.
BMC Ophthalmol ; 24(1): 302, 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39039541

RESUMO

PURPOSE: To investigate the safety and efficacy of a new micro-controlled radiofrequency device for treatment of conjunctivochalasis (Cch). METHODS: Data of 127 patients (230 eyes) who underwent ophthalmic radiofrequency treatment for Cch from January 2020 to June 2023 were analyzed retrospectively. Cch coagulation was performed with a radiofrequency electrode tip (OcuRF®, Ilooda, Korea) and a high-frequency radio-wave electric unit (0.6 ~ 0.8 watts, 2 MHz, Acutron™, Ilooda, Korea). Pre- and postoperative Cch grading, slit-lamp photography, tear film break-up time (TBUT), and bulbar conjunctival hyperemia using Keratograph 5 M (Oculus, Wetzlar, Germany) were evaluated. Cch grade 0 or 1 after surgery was regarded as 'success'. Complications, recurrence, and additional treatment rates were analyzed. RESULTS: In 227 (98.7%) eyes, the radiofrequency treatment led to marked improvement of Cch, with 224 (97.4%) eyes achieving grade 0 or 1 at 2 months postoperatively. Eight eyes (3.5%) received additional treatment. TBUT improved from 3.17 ± 0.82 s to 5.28 ± 1.10 s after surgery (P < 0.001). The total bulbar conjunctival hyperemia value showed an improvement from 1.7 ± 0.6 to 1.4 ± 0.6 postoperatively (P < 0.05). No serious complications were observed. CONCLUSION: The novel ophthalmic radiofrequency device led to a marked improvement of Cch with no serious adverse events during the entire follow-up period. Our results suggest that the radiofrequency device presents a safe and efficacious treatment option for Cch.


Assuntos
Doenças da Túnica Conjuntiva , Humanos , Feminino , Masculino , Estudos Retrospectivos , Doenças da Túnica Conjuntiva/cirurgia , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Adulto , Idoso de 80 Anos ou mais , Túnica Conjuntiva/cirurgia , Seguimentos
3.
Children (Basel) ; 11(7)2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-39062285

RESUMO

BACKGROUND: Nasal high-frequency oscillatory ventilation (nHFOV) has emerged as an effective initial and rescue noninvasive respiratory support mode for preterm infants with respiratory distress syndrome (RDS); however, little is known about nHFOV use in Romanian neonatal intensive care units (NICUs). OBJECTIVES: We aimed to identify the usage extent and clinical application of nHFOV in Romania. METHODS: A structured web-based questionnaire was designed to find the rate of nHFOV use and knowledge of this new method of noninvasive respiratory support in Romanian level III NICUs. Using multiple-choice, open-ended, and yes/no questions, we collected information on the NICU's size, noninvasive respiratory support modes used, nHFOV use, indications, settings, nasal interfaces, secondary effects, and equipment used. Descriptive statistics and comparisons were performed using IBM SPSS Statistics 26.0. RESULTS: A total of 21/23 (91.3%) leaders from level III NICUs (median [IQR] number of beds of 10 [10-17.5]) responded to the survey. The most frequently used noninvasive ventilation modes were CPAP mode on mechanical ventilators (76.2%), followed by NIPPV (76.2%); heated, humidified high-flow nasal cannula (HHHFNC) (61.9%); and nHFOV (11/21 units; 52.4%). A total of 5/11 units reported frequent nHFOV use (in two or more newborns/month) in both term and preterm infants. The main indications reported for nHFOV use were CPAP failure (90.9%), hypercapnia (81.8%), and bronchopulmonary dysplasia (72.7%). Face/nasal masks and short binasal prongs are the most commonly used nasal interfaces (90.9% and 72.7%, respectively). Air leaks at the interface level (90.9%), thick secretions (81.8%), and airway obstruction (63.6%) were the most frequently mentioned adverse effects of nHFOV. Only three of the NICUs had a written protocol for nHFOV use. Most units not yet using nHFOV cited lack of equipment, experience, training, or insufficient information and evidence for the clinical use and outcome of nHFOV use in neonates as the main reasons for not implementing this noninvasive respiratory mode. CONCLUSIONS: Our survey showed that nHFOV is already used in more than half of the Romanian level III NICUs to support term and preterm infants with respiratory distress despite a lack of consensus regarding indications and settings during nHFOV.

4.
Clin Neurophysiol ; 165: 154-165, 2024 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-39033697

RESUMO

OBJECTIVE: This study aimed at investigating the effect of median nerve stimulation on ipsilateral cortical potentials evoked by contralateral median nerve electrical stimulation. METHODS: We recorded somatosensory-evoked potentials (SEPs) from the left parietal cortex in 15 right-handed, healthy subjects. We administered bilateral median nerve stimulation, with the ipsilateral stimulation preceding the stimulation on the contralateral by intervals of 5, 10, 20, or 40 ms. We adjusted these intervals based on each individual's N20 latency. As a measure of S1 excitability, the amplitude of the N20 and the area of the High Frequency Oscillation (HFO) burst were analyzed for each condition. RESULTS: The results revealed significant inhibition of N20 amplitude by ipsilateral median nerve stimulation at interstimulus intervals (ISIs) between 5 and 40 ms. Late HFO burst was suppressed at short ISIs of 5 and 10 ms, pointing to a transcallosal inhibitory effect on S1 intracortical circuits. CONCLUSIONS: Findings suggest interhemispheric interaction between the primary somatosensory areas, supporting the existence of transcallosal transfer of tactile information. SIGNIFICANCE: This study provides valuable insights into the interhemispheric connections between primary sensory areas and underscore the potential role of interhemispheric interactions in somatosensory processing.

5.
Brain Behav ; 14(7): e3605, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38956819

RESUMO

BACKGROUND: High-frequency repeated transcranial magnetic stimulation (rTMS) stimulating the primary motor cortex (M1) is an alternative, adjunctive therapy for improving the motor symptoms of Parkinson's disease (PD). However, whether the high frequency of rTMS positively correlates to the improvement of motor symptoms of PD is still undecided. By controlling for other parameters, a disease animal model may be useful to compare the neuroprotective effects of different high frequencies of rTMS. OBJECTIVE: The current exploratory study was designed to compare the protective effects of four common high frequencies of rTMS (5, 10, 15, and 20 Hz) and iTBS (a special form of high-frequency rTMS) and explore the optimal high-frequency rTMS on an animal PD model. METHODS: Following high frequencies of rTMS application (twice a week for 5 weeks) in a MPTP/probenecid-induced chronic PD model, the effects of the five protocols on motor behavior as well as dopaminergic neuron degeneration levels were identified. The underlying molecular mechanisms were further explored. RESULTS: We found that all the high frequencies of rTMS had protective effects on the motor functions of PD models to varying degrees. Among them, the 10, 15, and 20 Hz rTMS interventions induced comparable preservation of motor function through the protection of nigrostriatal dopamine neurons. The enhancement of brain-derived neurotrophic factor (BDNF), dopamine transporter (DAT), and vesicular monoamine transporter 2 (VMAT-2) and the suppression of TNF-α and IL-1ß in the nigrostriatum were involved in the process. The efficacy of iTBS was inferior to that of the above three protocols. The effect of 5 Hz rTMS protocol was weakest. CONCLUSIONS: Combined with the results of the present study and the possible side effects induced by rTMS, we concluded that 10 Hz might be the optimal stimulation frequency for preserving the motor functions of PD models using rTMS treatment.


Assuntos
Modelos Animais de Doenças , Camundongos Endogâmicos C57BL , Transtornos Parkinsonianos , Probenecid , Estimulação Magnética Transcraniana , Animais , Estimulação Magnética Transcraniana/métodos , Camundongos , Masculino , Probenecid/farmacologia , Transtornos Parkinsonianos/induzido quimicamente , Transtornos Parkinsonianos/terapia , Transtornos Parkinsonianos/metabolismo , Transtornos Parkinsonianos/fisiopatologia , Fator Neurotrófico Derivado do Encéfalo/metabolismo , Córtex Motor/metabolismo , Córtex Motor/fisiopatologia , Neurônios Dopaminérgicos/metabolismo , Proteínas da Membrana Plasmática de Transporte de Dopamina/metabolismo , Interleucina-1beta/metabolismo , Substância Negra/metabolismo , Corpo Estriado/metabolismo , Proteínas Vesiculares de Transporte de Monoamina/metabolismo , Intoxicação por MPTP/terapia , Intoxicação por MPTP/prevenção & controle , Intoxicação por MPTP/metabolismo , Intoxicação por MPTP/fisiopatologia , Atividade Motora/fisiologia , 1-Metil-4-Fenil-1,2,3,6-Tetra-Hidropiridina/farmacologia
6.
Clin Exp Ophthalmol ; 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38964827

RESUMO

BACKGROUND: A high-frequency point-of-care (POC) ultrasound instrument was used to evaluate the microstructural and biomechanical properties of the anterior sclera in vivo using parameters computed from quantitative ultrasound (QUS) methods. METHODS: In this cross-sectional study, both eyes of 85 enrolled patients were scanned with the POC instrument and ultrasound data were processed to obtain QUS parameters. Pearson correlation and multi-linear regression were used to identify relationships between QUS parameters and refractive error (RE) or axial length. After categorising eyes based on RE, binary support vector machine (SVM) classifiers were trained using the QUS or ophthalmic parameters (anterior chamber depth, central corneal thickness, corneal power, and intraocular pressure) to classify each eye. Classifier performance was evaluated by computing the area under the receiver-operating characteristic curve (AUC). RESULTS: Individual QUS parameters correlated with RE and axial length (p < 0.05). Multi-linear regression revealed significant correlation between the set of QUS parameters and both RE (R = 0.49, p < 0.001) and axial length (R = 0.46, p = 0.001). Classifiers trained with QUS parameters achieved higher AUC (𝑝 = 0.06) for identifying myopic eyes (AUC = 0.71) compared to classifiers trained with ophthalmic parameters (AUC = 0.63). QUS-based classifiers attained the highest AUC when identifying highly myopic eyes (AUC = 0.77). CONCLUSIONS: QUS parameters correlate with progressing myopia and may be indicative of myopia-induced microstructural and biomechanical changes in the anterior sclera. These methods may provide critical clinical information complementary to standard ophthalmic measurements for predicting myopia progression and risk assessment for posterior staphyloma formation.

7.
Sci Rep ; 14(1): 15343, 2024 07 03.
Artigo em Inglês | MEDLINE | ID: mdl-38961222

RESUMO

This study aimed to construct a non-invasive diagnostic nomogram based on high-frequency ultrasound and magnetic resonance imaging results for early liver cirrhosis patients with chronic hepatitis B (CHB) which cannot be detected by conventional non-invasive examination methods but can only be diagnosed through invasive liver puncture for pathological examination. 72 patients with CHB were enrolled in this prospective study, and divided into S4 stage of liver cirrhosis and S0-S3 stage of non-liver cirrhosis according to pathological findings. Binary logistic regression analysis was performed to identify independent predictors, and a diagnostic nomogram was constructed for CHB-related early cirrhosis. It was validated and calibrated by bootstrap self-extraction. Binary logistic regression analysis showed that age (OR 1.14, 95% CI (1.04-1.27)), right hepatic vein diameter (OR 0.43, 95% CI 0.23-0.82), presence or absence of nodules (OR 31.98, 95% CI 3.84-266.08), and hepatic parenchymal echogenicity grading (OR 12.82, 95% CI 2.12-77.51) were identified as independent predictive indicators. The nomogram based on the 4 factors above showed good performance, with a sensitivity and specificity of 90.70% and 89.66%, respectively. The area under the curve (AUC) of the prediction model was 0.96, and the predictive model showed better predictive performance than APRI score (AUC 0.57), FIB-4 score (AUC 0.64), INPR score (AUC 0.63), and LSM score (AUC 0.67). The calibration curve of the prediction model fit well with the ideal curve, and the decision curve analysis showed that the net benefit of the model was significant. The nomogram in this study can detect liver cirrhosis in most CHB patients without liver biopsy, providing a direct, fast, and accurate practical diagnostic tool for clinical doctors.


Assuntos
Hepatite B Crônica , Cirrose Hepática , Nomogramas , Ultrassonografia , Humanos , Cirrose Hepática/diagnóstico , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Cirrose Hepática/complicações , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Prospectivos , Hepatite B Crônica/complicações , Hepatite B Crônica/patologia , Adulto , Imageamento por Ressonância Magnética/métodos , Fígado/patologia , Fígado/diagnóstico por imagem
8.
BMC Neurol ; 24(1): 232, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38965567

RESUMO

BACKGROUND: High-frequency headache/migraine (HFM) and overuse of acute medication (medication overuse [MO]) are associated with increased disability and impact. Experiencing both HFM and MO can potentially compound impacts, including stigma; however, evidence of this is limited. The objective of this report was to evaluate self-reported stigma, health-related quality of life (HRQoL), disability, and migraine symptomology in US adults with HFM + MO from the Harris Poll Migraine Report Card survey. METHODS: US adults (≥ 18 yrs., no upper age limit) who screened positive for migraine per the ID Migraine™ screener completed an online survey. Participants were classified into "current HFM + MO" (≥ 8 days/month with headache/migraine and ≥ 10 days/month of acute medication use over last few months) or "previous HFM + MO" (previously experienced HFM + MO, headaches now occur ≤ 7 days/month with ≤ 9 days/month of acute medication use). Stigma, HRQoL, disability, and most bothersome symptom (MBS) were captured. The validated 8-item Stigma Scale for Chronic Illnesses (SSCI-8) assessed internal and external stigma (scores ≥ 60 are clinically significant). Raw data were weighted to the US adult population. Statistically significant differences were determined by a standard t-test of column proportions and means at the 90% (p < 0.1) and 95% (p < 0.05) confidence levels. RESULTS: Participants (N = 550) were categorized as having current (n = 440; mean age 41.1 years; 54% female; 57% White, not Hispanic; 24% Hispanic; 11% Black, not Hispanic) or previous (n = 110; mean age 47.2 years; 49% female; 75% White, not Hispanic; 13% Hispanic; 4% Black, not Hispanic) HFM + MO. Compared to those with previous HFM + MO (21%), adults with current HFM + MO were more likely to experience clinically significant levels of stigma (47%). Men with current HFM + MO (52% compared to men with previous HFM + MO [25%] and women with current [41%] or previous [18%] HFM + MO), non-Hispanic Black (51% compared to White, not Hispanic [45%] and Hispanic [48%] current HFM + MO groups and White, not Hispanic previous HFM + MO [12%]), current HFM + MO aged 18-49 years (50% compared to those with current HFM + MO aged ≥ 50 years [33%] and those with previous HFM + MO aged 18-49 [34%] and ≥ 50 years [4%]), and employed respondents (53% current and 29% previous compared to those not employed [32% current and 12% previous]) reported higher rates of clinically significant stigma. Those with current HFM + MO were more likely to have worse HRQoL and disability due to headache/migraine. Respondents aged ≥ 50 years with current HFM + MO were more likely than respondents aged 18-49 years with current HFM + MO to indicate that their overall quality of life (66% vs. 52%) and their ability to participate in hobbies/activities they enjoy were negatively impacted by headache/migraine (61% vs. 49%). Pain-related symptoms were identified as the MBS. CONCLUSIONS: Together these data suggest that current and previous HFM + MO can be associated with undesirable outcomes, including stigma and reduced HRQoL, which were greatest among people with current HFM + MO, but still considerable for people with previous HFM + MO.


Assuntos
Transtornos de Enxaqueca , Qualidade de Vida , Estigma Social , Humanos , Masculino , Feminino , Adulto , Qualidade de Vida/psicologia , Transtornos de Enxaqueca/epidemiologia , Transtornos de Enxaqueca/psicologia , Transtornos de Enxaqueca/tratamento farmacológico , Pessoa de Meia-Idade , Adulto Jovem , Adolescente , Inquéritos e Questionários , Cefaleia/epidemiologia , Cefaleia/psicologia , Cefaleia/tratamento farmacológico
9.
Epilepsia Open ; 2024 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-38970780

RESUMO

OBJECTIVE: This study evaluates the performance of the novel MRI sequence stimulus-induced rotary saturation (SIRS) to map responses to interictal epileptic activity in the human cortex. Spin-lock pulses have been applied to indirectly detect neuronal activity through magnetic field perturbations. Following initial reports about the feasibility of the method in humans and animals with epilepsy, we aimed to investigate the diagnostic yield of spin-lock MR pulses in comparison with scalp-EEG in first seizure patients. METHODS: We employed a novel method for measurements of neuronal activity through the detection of a resonant oscillating field, stimulus-induced rotary saturation contrast (SIRS) at spin-lock frequencies of 120 and 240 Hz acquired at a single 3T MRI system. Within a prospective observational study, we conducted SIRS experiments in 55 patients within 7 days after a suspected first unprovoked epileptic seizure and 61 healthy control subjects. In this study, we report on the analysis of data from a single 3T MRI system, encompassing 35 first seizure patients and 31 controls. RESULTS: The SIRS method was applicable in all patients and healthy controls at frequencies of 120 and 240 Hz. We did not observe any significant age- or sex-related differences. Specificity of SIRS at 120 Hz was 90.3% and 93.5% at 240 Hz. Sensitivity was 17.1% at 120 Hz and 40.0% at 240 Hz. SIGNIFICANCE: SIRS targets neuronal oscillating magnetic fields in patients with epilepsy. The coupling of presaturated spins to epilepsy-related magnetic field perturbations may serve as a-at this stage experimental-diagnostic test in first seizure patients to complement EEG findings as a standard screening test. PLAIN LANGUAGE SUMMARY: Routine diagnostic tests carry several limitations when applied after a suspected first seizure. SIRS is a noninvasive MRI method to enable time-sensitive diagnosis of image correlates of epileptic activity with increased sensitivity compared to routine EEG.

10.
Ultrasound J ; 16(1): 36, 2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-39017903

RESUMO

BACKGROUND: By combining high-frequency and contrast-enhanced ultrasound (CEUS), the position of the severed end of a finger extensor tendon injury and the injury classification can be determined as part of a comprehensive preoperative evaluation in clinical practice. However, there have been no reports of high-frequency ultrasound combined with CEUS for the preoperative diagnosis of human finger extensor tendon injury. CASES PRESENTATION: One case of complete rupture of the extensor tendon was diagnosed by ultrasound, which was completely consistent with the surgery; one case of incomplete rupture was ultimately confirmed clinically; and one case of distal phalangeal bone base avulsion fracture with tendon contusion and missed diagnosis on the first radiographic examination was confirmed by follow-up radiographic examination. CONCLUSIONS: Different types of finger extensor tendon injuries exhibit distinctive contrast-enhanced ultrasonography findings. Combined high-frequency and contrast-enhanced ultrasound can accurately locate the position of the severed end of the finger extensor tendon injury before surgery while observing the contrast agent filling area to clarify injury classification, providing a reliable imaging basis for clinical practice and ultimately developing personalized diagnosis and treatment plans for patients to ensure minimal trauma and pain, as well as optimal treatment effects.

11.
Echocardiography ; 41(8): e15886, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39007877

RESUMO

BACKGROUND: Due to insufficient near-field resolution and artifacts, it is challenging to evaluate the left ventricular apical perfusion with phased-array probes. By combining high-frequency linear probe and contrast-enhanced ultrasound (CEUS), imaging of apical myocardial perfusion could be improved. The study aims to evaluate the preliminary application of CEUS by high-frequency linear probes to assess the apical perfusion. METHODS: The study enrolled retrospectively 91 patients to test the feasibility of the novel method. In protocol 1, patients were stratified into a group with left anterior descending artery (LAD) stenosis (N = 40) and a group without LAD stenosis or coronary artery disease (N = 41) based on the degree of coronary artery narrowing, quantified by >50% stenosis in coronary angiography. Receiver operating characteristics (ROC) analysis was performed to test the diagnostic value of perfusion parameters. In protocol 2, the reproducibility of high-frequency linear probe in apical perfusion analysis was compared with the conventional phased-array probe in 30 patients. RESULTS: (1) The novel method is feasible in 81(89.01%) patients. (2) In protocol 1, to detect LAD stenosis, the best cut-off of ß, T, A, and MBF were 10.32, 3.28, 9.39, and 4.99, respectively. Area under the curve of ß, T, A, and MBF were .880, .881, .761, and .880, respectively. (3) In protocol 2, compared with phased-array probe, the quantitative analysis of high-frequency linear probe is of high reproducibility and could get good curve fitting (R2 = .29 vs. R2 = .71, P < .01). CONCLUSION: Observation of apical perfusion using this method is feasible and quantitative analysis allows an accurate and convenient identification of LAD stenosis. This method provides an alternative for patients who have difficulties in visualizing the apical region with a phased-array probe.


Assuntos
Meios de Contraste , Estudos de Viabilidade , Humanos , Masculino , Feminino , Reprodutibilidade dos Testes , Estudos Retrospectivos , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/métodos , Ecocardiografia/métodos , Aumento da Imagem/métodos , Idoso , Sensibilidade e Especificidade , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Estenose Coronária/fisiopatologia , Estenose Coronária/diagnóstico por imagem , Desenho de Equipamento
12.
World J Clin Cases ; 12(18): 3321-3331, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38983415

RESUMO

BACKGROUND: Sudden sensorineural hearing loss (SSNHL), characterized by a rapid and unexplained loss of hearing, particularly at moderate to high frequencies, presents a significant clinical challenge. The therapeutic use of methylprednisolone sodium succinate (MPSS) via different administration routes, in combination with conventional medications, remains a topic of interest. AIM: To compare the therapeutic efficacy of MPSS administered via different routes in combination with conventional drugs for the treatment of mid- to high-frequency SSNHL. METHODS: The medical records of 109 patients with mid- to high-frequency SSNHL were analyzed. The patients were divided into three groups based on the route of administration: Group A [intratympanic (IT) injection of MPSS combined with mecobalamin and Ginkgo biloba leaf extract injection], Group B (intravenous injection of MPSS combined with mecobalamin and Ginkgo biloba leaf extract injection), and Group C (single IT injection of MPSS). The intervention effects were compared and analyzed. RESULTS: The posttreatment auditory thresholds in Group A (21.23 ± 3 .34) were significantly lower than those in Groups B (28.52 ± 3.36) and C (30.23 ± 4.21; P < 0.05). Group A also exhibited a significantly greater speech recognition rate (92.23 ± 5.34) than Groups B and C. The disappearance time of tinnitus, time to hearing recovery, and disappearance time of vertigo in Group A were significantly shorter than those in Groups B and C (P < 0.05). The total effective rate in Group A (97.56%) was significantly greater than that in Groups B and C (77.14% and 78.79%, χ 2 = 7.898, P = 0.019). Moreover, the incidence of adverse reactions in Groups A and C was significantly lower than that in Group B (4.88%, 3.03% vs 2.57%, χ 2 = 11.443, P = 0.003), and the recurrence rate in Group A was significantly lower than that in Groups B and C (2.44% vs 20.00% vs 21.21%, χ 2 = 7.120, P = 0.028). CONCLUSION: IT injection of MPSS combined with conventional treatment demonstrates superior efficacy and safety compared to systemic administration via intravenous infusion and a single IT injection of MPSS. This approach effectively improves patients' hearing and reduces the risk of disease recurrence.

13.
Sensors (Basel) ; 24(13)2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-39000927

RESUMO

The phenomenon of high-frequency distortion (HFD) in the electric grids, at both low-voltage (LV) and medium-voltage (MV) levels, is gaining increasing interest within the scientific and technical community due to its growing occurrence and the associated impact. These disturbances are mainly injected into the grid by new installed devices, essential for achieving decentralized generation based on renewable sources. In fact, these generation systems are connected to the grid through power converters, whose switching frequencies are significantly increasing, leading to a corresponding rise in the frequency of the injected disturbances. HFD represents a quite recent issue, but numerous scientific papers have been published in recent years on this topic. Furthermore, various international standards have also covered it, to provide guidance on instrumentation and related algorithms and indices for the measurement of these phenomena. When measuring HFD in MV grids, it is necessary to use instrument transformers (ITs) to scale voltages and currents to levels fitting with the input stages of power quality (PQ) instruments. In this respect, the recently released Edition 2 of the IEC 61869-1 standard extends the concept of the IT accuracy class up to 500 kHz; however, the IEC 61869 standard family provides guidelines on how to test ITs only at power frequency. This paper provides an extensive review of literature, standards, and the main outputs of European research projects focusing on HFD and ITs. This preliminary study of the state-of-the-art represents an essential starting point for defining significant waveforms to test ITs and, more generally, to achieve a comprehensive understanding of HFD. In this framework, this paper provides a summary of the most common ranges of amplitude and frequency variations of actual HFD found in real grids, the currently adopted measurement methods, and the normative open challenges to be addressed.

14.
Sensors (Basel) ; 24(13)2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-39001196

RESUMO

Disturbances in the aviation environment can compromise the stability of the aviation optoelectronic stabilization platform. Traditional methods, such as the proportional integral adaptive robust (PI + ARC) control algorithm, face a challenge: once high-frequency disturbances are introduced, their effectiveness is constrained by the control system's bandwidth, preventing further stability enhancement. A state equalizer speed closed-loop control algorithm is proposed, which combines proportional integral adaptive robustness with state equalizer (PI + ARC + State equalizer) control algorithm. This new control structure can suppress high-frequency disturbances caused by mechanical resonance, improve the bandwidth of the control system, and further achieve fast convergence and stability of the PI + ARC algorithm. Experimental results indicate that, in comparison to the control algorithm of PI + ARC, the inclusion of a state equalizer speed closed-loop compensation in the model significantly increases the closed-loop bandwidth by 47.6%, significantly enhances the control system's resistance to disturbances, and exhibits robustness in the face of variations in the model parameters and feedback sensors of the control object. In summary, integrating a state equalizer speed closed-loop with PI + ARC significantly enhances the suppression of high-frequency disturbances and the performance of control systems.

15.
Diagnostics (Basel) ; 14(13)2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-39001225

RESUMO

INTRODUCTION: Periodontal disease is an infectious syndrome presenting inflammatory aspects. Radiographic evaluation is an essential complement to clinical assessment but has limitations such as the impossibility of assessing tissue inflammation. It seems essential to consider new exploration methods in clinical practice. Ultrasound of periodontal tissues could make it possible to visualize periodontal structures and detect periodontal diseases (periodontal pocket measurement and the presence of intra-tissue inflammation). Clinical Innovation Report: An ultrasound probe has been specially developed to explore periodontal tissues. The objective of this clinical innovation report is to present this device and expose its potential. DISCUSSION: Various immediate advantages favor using ultrasound: no pain, no bleeding, faster execution time, and an image recording that can be replayed without having to probe the patient again. Ultrasound measurements of pocket depth appear to be as reliable and reproducible as those obtained by manual probing, as do tissue thickness measurements and the detection of intra-tissue inflammation. CONCLUSIONS: Ultrasound seems to have a broad spectrum of indications. Given the major advances offered by ultrasound imaging as a complementary aid to diagnosis, additional studies are necessary to validate these elements and clarify the potential field of application of ultrasound imaging in dentistry.

16.
Cancers (Basel) ; 16(13)2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-39001518

RESUMO

BACKGROUND: Primary cutaneous lymphoma (PCL) is a rare form of extranodal non-Hodgkin's lymphoma characterized by malignant lymphocytes confined to the skin. Accurate diagnosis and staging are crucial for optimal management, yet radiological literature on imaging PCL remains limited. This study aims to delineate the imaging characteristics of PCLs using high and ultra-high frequency ultrasound (UHFUS) and proposes a classification system based on ultrasound findings. METHODS: A cohort of 88 individuals with suspected PCL underwent high-resolution ultrasound (HRUS) and color Doppler examination of lesions. Lesions were categorized based on sonographic appearance, and subsequent histopathological assessment confirmed the diagnosis. RESULTS: Ultrasound imaging revealed distinct patterns for primary cutaneous T-cell lymphomas (PCTCL) and primary cutaneous B-cell lymphomas (PCBCL), with characteristic features such as hypoechoic nodules, pseudonodular lesions, and dermal infiltration. Histopathological analysis confirmed the ultrasound findings, supporting the proposed classification system. CONCLUSIONS: Ultrasonography, particularly UHFUS, offers valuable insights into the imaging characteristics of primary cutaneous lymphomas, aiding the accurate diagnosis and assessment of treatment response. The proposed classification system based on ultrasound findings enhances the diagnostic approach to PCLs, and paves the way for improved patient care and management strategies.

17.
Sci Rep ; 14(1): 16091, 2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-38997273

RESUMO

Accumulation of α-synuclein (α-Syn) has been implicated in proteasome and autophagy dysfunction in Parkinson's disease (PD). High frequency electrical stimulation (HFS) mimicking clinical parameters used for deep brain stimulation (DBS) in vitro or DBS in vivo in preclinical models of PD have been found to reduce levels of α-Syn and, in certain cases, provide possible neuroprotection. However, the mechanisms by which this reduction in α-Syn improves cellular dysfunction associated with α-Syn accumulation remains elusive. Using HFS parameters that recapitulate DBS in vitro, we found that HFS led to a reduction of mutant α-Syn and thereby limited proteasome and autophagy impairments due to α-Syn. Additionally, we observed that HFS modulates via the ATP6V0C subunit of V-ATPase and mitigates α-Syn mediated autophagic dysfunction. This study highlights a role for autophagy in reduction of α-Syn due to HFS which may prove to be a viable approach to decrease pathological protein accumulation in neurodegeneration.


Assuntos
Autofagia , alfa-Sinucleína , alfa-Sinucleína/metabolismo , Humanos , Doença de Parkinson/metabolismo , Doença de Parkinson/terapia , Animais , Estimulação Elétrica/métodos , Estimulação Encefálica Profunda/métodos , Complexo de Endopeptidases do Proteassoma/metabolismo , ATPases Vacuolares Próton-Translocadoras/metabolismo , Camundongos
18.
Sci Total Environ ; 947: 174372, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38960183

RESUMO

The southeastern Bay of Biscay has been described as a "dead end" for floating marine litter, often accumulating along small-scale linear streaks. Coastal Current Convergence Structures (CCS), often associated with vertical motions at river plume edges, estuarine fronts, or other physical processes, can be at the origin of the accumulation. Understanding the formation of CCS and their role in the transport of marine litter is essential to better quantify and to help mitigate marine litter pollution. The Lagrangian framework, used to estimate the absolute dispersion, and the finite-size Lyapunov exponents (FSLE), have proved very effective for identifying CCS in the current velocity field. However, the quality of CCS identification depends strongly on the Eulerian fields. Two surface current velocity data sets were used in the analysis: the remotely sensed velocities from the EuskOOS High-Frequency Radar (HFR) network and velocities from three-dimensional model outputs. They were complemented by drifting buoy velocity measurements. An optimization method, involving the fusion of drifting buoys and HFR velocities is proposed to better reconstruct the fine-scale structure of the current velocity field. Merging these two sources of velocity data reduced the mean Lagrangian error and the Root Mean Square Error (RMSE) by 50 % and 30 % respectively, significantly improving velocity reconstruction. FSLE ridgelines obtained from the Lagrangian analysis of optimized velocities were compared with remotely sensed concentrations of Chlorophyll-a. It was shown that ridgelines control the spatial distribution of phytoplankton. They fundamentally represent the CCS which can potentially affect marine litter aggregation. Analysis of the absolute dispersion revealed large stirring in the alongshore direction which was also confirmed by spatial distribution of FSLE ridgelines. The alignment between FSLE ridgelines and patterns of high Chlorophyll-a concentration was observed, often determining the limits of river plume expansion in the study area.

19.
HardwareX ; 19: e00539, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38957267

RESUMO

A novel High-Frequency Electric Energy Metering System to inspect non-conventional features that may be relevant for studying real-time energy disaggregation and control of household appliances is presented. Integration of a data acquisition and control board, designed and built to be assembled with an Arduino Due, with the M90E36A Demo Board, allows for flexible and configurable electrical energy measurements. A key feature is that up to 4 current channels can be measured synchronously. On the one hand, samples can be obtained and processed by the M90E36A IC internal Digital Signal Processor at 3 Hz in the time domain and 2 Hz in the frequency domain. On the other hand, the M90E36A IC direct access memory mode can be operated, allowing 8 kHz pure voltage and current signals to be obtained. Finally, integration with Raspberry Pi allows to design and incorporate a custom signal processor into the study. Additionally, in this article, an application example is presented where the variation of the residual harmonic components of a household appliance is obtained.

20.
Semin Pediatr Surg ; 33(4): 151439, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38986241

RESUMO

This review focuses on contemporary mechanical ventilator practices used in the initial management of neonates born with congenital diaphragmatic hernia (CDH). Both conventional and non-conventional ventilation modes in CDH are reviewed. Special emphasis is placed on the rationale for gentle ventilation and the current evidence-based clinical practice guidelines that are recommended for supporting these fragile infants. The interplay between CDH lung hypoplasia and other key cardiopulmonary elements of the disease, namely a reduced pulmonary vascular bed, abnormal pulmonary vascular remodeling, and left ventricular hypoplasia, are discussed. Finally, we provide insights into future avenues for mechanical ventilator research in CDH.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...