1.
Artigo em Inglês | MEDLINE | ID: mdl-38837465

RESUMO

AIM: The aim of this study on native human cadavers was to compare clinical, sonographic, and radiological measurements of fenestrations, dehiscences, and 3-wall bone defects on implants. MATERIALS AND METHODS: The examination was carried out on five human mandibles. After the insertion of 27 implants, dehiscences (n = 14), fenestrations (n = 7) and 3-wall bone defects (n = 6) were prepared in a standardized manner. The direct measurement of the bone defects was carried out with a periodontal probe and the radiological examination was carried out using digital volume tomography (DVT). The ultrasound examination (US) was performed using a clinical 24-MHz US imaging probe. Means and standard deviations of the direct, US, and DVT measurements were calculated. Measurements were statistically compared using the Pearson correlation coefficient and Bland-Altman analysis. RESULTS: Bone defects were on average 3.22 ± 1.58 mm per direct measurement, 2.90 ± 1.47 mm using US, and 2.99 ± 1.52 mm per DVT assessment. Pairwise correlations of these measurements were R = .94 (p < .0001) between direct and US, R = .95 (p < .0001) between DVT and US, and R = .96 (p < .0001) between direct and DVT. The mean differences of the measurements (and 95% CI) between direct and US was 0.41 (-0.47 to 1.29), US and DVT 0.33 (-0.30 to 0.97), and direct and DVT 0.28 (-0.50 to 1.07). CONCLUSION: All peri-implant bone defects could be identified and sonographically measured. US measurements showed a strong correlation with direct and DVT measurements. The sonographic measurement accuracy was highest for dehiscences, followed by fenestrations and 3-wall bone defects.

2.
Lasers Surg Med ; 56(4): 382-391, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38570914

RESUMO

BACKGROUND AND OBJECTIVES: Femtosecond laser trabeculotomy (FLT) creates aqueous humor outflow channels through the trabecular meshwork (TM) and is an emerging noninvasive treatment for open-angle glaucoma. The purpose of this study is to investigate the effect of pulse energy on outflow channel creation during FLT. MATERIALS AND METHODS: An FLT laser (ViaLase Inc.) was used to create outflow channels through the TM (500 µm wide by 200 µm high) in human cadaver eyes using pulse energies of 10, 15, and 20 µJ. Following treatment, tissues were fixed in 4% paraformaldehyde. The channels were imaged using optical coherence tomography (OCT) and assessed as full thickness, partial thickness, or not observable. RESULTS: Pulse energies of 15 and 20 µJ had a 100% success rate in creating full-thickness FLT channels as imaged by OCT. A pulse energy of 10 µJ resulted in no channels (n = 6), a partial-thickness channel (n = 2), and a full-thickness FLT channel (n = 2). There was a statistically significant difference in cutting widths between the 10 and 15 µJ groups (p < 0.0001), as well as between the 10 and 20 µJ groups (p < 0.0001). However, there was no statistically significant difference between the 15 and 20 µJ groups (p = 0.416). CONCLUSIONS: Fifteen microjoules is an adequate pulse energy to reliably create aqueous humor outflow channels during FLT in human cadaver eyes. OCT is a valuable tool when evaluating FLT.


Assuntos
Glaucoma de Ângulo Aberto , Trabeculectomia , Humanos , Trabeculectomia/métodos , Glaucoma de Ângulo Aberto/cirurgia , Pressão Intraocular , Lasers , Cadáver
3.
Cureus ; 16(2): e53961, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38469026

RESUMO

Background Many studies have been conducted on the biomechanics of the spine to elucidate the fixation properties of spinal fusion surgery and the causes of instrumentation failure. Among these studies, there are some studies on load sharing in the spine and measurement using strain gauges and pressure gauges, but there is a lack of research on axial compressive loads. Methods Axial compressive load tests were performed on human cadaveric injured lumbar vertebrae fixed with pedicle screws (PS). Both the strain generated in the PS rod and the intradiscal pressure were measured. Subsequently, the stress generated in the PS rod and the load sharing of the spine and instrumentation were calculated. Results Even when only compressive load is applied, bending stress of more than 10 times the compression stress was generated in the rod, and the stress tended to concentrate on one rod. Rod deformation becomes kyphotic, in contrast to the lordotic deformation behavior of the lumbar spine. The stress shielding rate was approximately 40%, less than half. Conclusions This study obtained basic data useful for constructing and verifying numerical simulations that are effective for predicting and elucidating the causes of dislodgement and failure of spinal implants.

4.
J Mech Behav Biomed Mater ; 153: 106473, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38452573

RESUMO

The incidence of hamstring muscle strain varies among muscles, suggesting that the mechanical stresses associated with elongation may differ among muscles. However, the passive mechanical properties of whole human muscles have rarely been directly measured and clarified. This study aimed to clarify the stress-strain relationship of the hamstring muscles using a soft-embalmed Thiel cadaver. The long heads of the biceps femoris (BFlh), semimembranosus (SM), and semitendinosus (ST) muscles were dissected from eight cadavers. The proximal and distal hamstring tendons were affixed to the mechanical testing machine. Slack length was defined as the muscle length at the initial loading point detected upon the application of a tensile load. Muscle length was measured using a tape measure, and the anatomical cross-sectional area (ACSA) of the muscle was measured at the proximal and distal sites using B-mode ultrasonography. In the loading protocol, the muscle was elongated from its slack length to a maximum of 8% strain at an average rate of 0.83 L0/s, and the amount of displacement and tensile load were measured for each muscle. Further, the strain (%, displacement/slack muscle length) and stress (kPa, tensile load/ACSA) were calculated to evaluate the mechanical properties. Two-way repeated-measures analysis of variance (ANOVA) was used to compare stress changes with increasing muscle strain. A significant interaction between the muscle and strain factors was observed with respect to stress. Post-hoc tests revealed higher stresses in the BFlh and SM than in ST after 3% strain (P < 0.01). However, no significant differences were observed between the BFlh and SM groups. At 8% strain, the BFlh, SM, and ST exhibited stresses of 63.7 ± 12.1, 53.7 ± 23.2, and 21.0 ± 11.9 kPa, respectively. The results indicate that the stress changes associated with muscle strain differed among muscles. In particular, the stress applied to the three muscles at the same strain was found to be higher in the BFlh and SM. Thus, these findings suggest that increased mechanical stress during elongation may contribute to the frequent occurrence of muscle strain in BFlh and SM.


Assuntos
Músculos Isquiossurais , Humanos , Músculo Esquelético/fisiologia , Cadáver , Ultrassonografia , Análise de Variância
5.
Int J Med Educ ; 15: 8-14, 2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38308861

RESUMO

Objectives: This scoping review aimed to give an overview of the existing literature about ultrasound-guided labeling techniques of human cadaver ligaments and tried to work out the possibilities of integrating ultrasound into dissection courses. Methods: A literature review was carried out on the 3rd of January 2023, with relevant studies discovered in the following databases: MEDLINE, EMBASE, CENTRAL, BIOSIS Previews and Web of Science Core Collection. Grey literature was also considered. The reference lists of all relevant papers were scanned. Only ultrasound studies on human cadaver ligaments were included. The included studies' general characteristics and ultrasound-guided approaches to label the ligaments were taken from them and examined. Results: The search found 8899 matches, but only 96 of them met the criteria. The transverse carpal ligament (15.62%) and the annular pulleys (19.79%) were the ligaments that had received the greatest research attention. Twenty-three studies are included in the methodological analysis. Both the marking substrate and the injected volume were diverse. Although 65% of the included studies achieved 100% accuracy using the ultrasound directed labeling approaches. Conclusions: Ultrasound-guided labeling techniques achieve a high accuracy. Therefore, this methodology could be a potential teaching tool for students during the dissection course. But caution is advised in drawing general conclusions because of the small sample sizes and different methodologies in the studies. Future larger-scale research is necessary.


Assuntos
Ligamentos Articulares , Ultrassonografia de Intervenção , Humanos , Ultrassonografia , Ligamentos Articulares/diagnóstico por imagem , Ultrassonografia de Intervenção/métodos , Cadáver
6.
Curr Probl Cardiol ; 49(2): 102216, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37993008

RESUMO

OBJECTIVE: This study seeks to identify the ideal dilution rate of a radiopaque product to optimize the visualization of coronary arteries and their branches within human cadaver hearts. The process involves obtaining images in the anatomy laboratory and subsequently constructing a three-dimensional model. MATERIALS AND METHODS: We utilized 30 human hearts fixed in 10 % formalin (9 females and 21 males) with a mean age of 79 ± 5 years. The initial experiment, involving the first four hearts (referred to as "group 1"), encountered difficulties in opacifying coronary arteries. In this phase, a probabilistic injection of 20 % Visipaque and 80 % latex, with coronary sinus ostium closure, was performed. The optimal mixture ratio was then determined as 33 % Visipaque and 66 % latex. Recognizing the need for on-site injection at the CT Scan table, this protocol was applied to the subsequent 11 hearts in "group 2." Closure of the coronary sinus was deemed unnecessary. The final 15 hearts, constituting "group 3," revealed that the injection should be gradual, maintaining controlled pressure between 120 and 150 mm Hg. Post-injection, hearts were scanned with the injected coronary arteries using an Optima 660 CT scanner. Two-dimensional images were acquired with parameters set at 64 × 0.625 mm, 100 kV, 300-400 mA, and a rotation of 0.5 s. Subsequently, 3D reconstruction was conducted using Advantage Workstation 4.7 (GE Healthcare) and volume rendering with Volume Viewer software, version 15. RESULTS: Significant differences in the percentage of opacified coronaries were observed among the three groups (p < 0.005). This variation underscores the learning curve and comprehension required before establishing a reliable method. Group 1 (N = 4) demonstrated minimal opacification, group 2 (N = 11) displayed partial opacification, while group 3 (N = 15) achieved 100 % opacification of coronary arteries. CONCLUSION: The successive experiments culminated in the development of a protocol for CT imaging, enabling accurate three-dimensional reconstruction of the normal anatomy of the main and secondary coronary arteries. Our work is grounded in a series of progressively refined and successful experiments.


Assuntos
Vasos Coronários , Imageamento Tridimensional , Masculino , Feminino , Humanos , Idoso , Idoso de 80 Anos ou mais , Vasos Coronários/diagnóstico por imagem , Imageamento Tridimensional/métodos , Látex , Cadáver
7.
Front Surg ; 10: 1195728, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38107406

RESUMO

Introduction: A novel titanium tilting suture anchor was designed and fabricated using additive manufacturing. The anchor enjoyed a nonsymmetrical structure to facilitate its insertion procedure through a weight-induced tilt, a saw-teeth penetrating edge to provide a strong initial fixation into cancellous bones of various densities, and an appropriate surface texture to enhance the longterm fixation strength through bone ingrowth. Methods: Biomechanical tests were performed on 10 ovine and 10 human cadaveric humeri to examine the insertion procedure and assess the initial fixation strength of the anchor, in comparison with a standard screw-type anchor as control. Results: This study indicated a simple yet reliable insertion procedure for the tilting anchor. All anchors survived after 400 cycles of cyclic loadings and failed in the load-to-failure step. There were no significant differences between the displacements and fixation stiffnesses of the anchors in either group. The ultimate failure load was significantly smaller (p<0.05) for tilting anchors in ovine group (273.7 ± 129.72 N vs. 375.6 ± 106.36 N), but not different in human group (311.8 ± 82.55 N vs. 281.9 ± 88.35). Also, a larger number of tilting anchors were pulled out in ovine group (6 vs. 3) but a smaller number in human group (4 vs. 6). Conclusion: It was concluded that the biomechanical performance of the designed tilting anchor is comparable with that of the standard screw-type anchors.

8.
Artigo em Inglês | MEDLINE | ID: mdl-37822066

RESUMO

BACKGROUND: Some variations of the cerebral arterial circle (CAC) are associated with an increased risk for the development of various pathological conditions. This paper aimed to determine the prevalence of hypoplastic arteries of CAC and to emphasize the limited possibility of their visualization by computed tomography angiography (CTA). MATERIALS AND METHODS: The research was performed on 400 adult cadavers by macro- and microdissection of the cerebral arteries. Each case was photographed and the diameter of the arteries was measured digitally, by analyzing photographs of the bases of the brain in the ImageJ program. RESULTS: The largest prevalence of artery diameter <1mm (<0.6mm) in CAC had the posterior communicating artery (PCoA). PCoA on the left side was hypoplastic in 44.9% (11.4%) of cases, while the same artery on the right side was hypoplastic in 44.3% (6.6%) of cases. The posterior cerebral artery was hypoplastic on the left side in 3% (0.6%) and on the right side in 4.2% (0.6%) of cases. The anterior cerebral artery had a hypoplastic caliber only on the right side in 2.4% (0.6%) of the cases, while the internal carotid arteries did not have a diameter <1mm in any case. The anterior communicating artery showed the greatest variability in morphology. Studies on CTA describe the occurrence of aplasia in a statistically significantly higher percentage, and the occurrence of hypoplastic arteries in a statistically significantly lower percentage compared to studies on cadavers. CONCLUSIONS: Due to significant differences between cadaveric and radiological studies, it is necessary to analyze their results regarding arterial hypoplasia and aplasia separately. A diameter of less than 1 mm has been suggested as a criterion for arterial hypoplasia.

9.
J Endod ; 49(8): 1035-1043, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37348814

RESUMO

INTRODUCTION: A major challenge in dentistry is the replacement of teeth lost prematurely due to trauma, caries, or malformations; especially in growing patients. The aim of this study was to assess the accuracy of CAD-CAM surgically guided tooth autotransplantation in cryopreserved cadaver mandibles using guided templates and custom-designed osteotomes. METHODS: Cryopreserved human cadaver heads were digitized and scanned using an intraoral optical scanner and a large-volume cone beam computed tomography device. First, virtual surgical planning was performed to create a 3D tooth replica, 2 surgical guides, and a custom-made osteotome for each single-rooted tooth autotransplantation procedure/case. Surgical sockets were created in the selected mandibles using guided tooling consisting of an initial guided osteotomy with implant burs and a final guided osteotomy using custom osteotomes. After tooth autotransplantation, second large-volume cone beam computed tomography images of the 5 cadaver mandibles were obtained. The discrepancy in mm within the 3D space (apical and mesiodistal deviations) between the final position of the autotransplanted teeth and their digitally planned 3D initial position was calculated and analyzed statistically (P < .05). RESULTS: All donor teeth were placed without incident within their newly created sockets in the real mandibles. The mean difference between the digitally planned root apex position and the final tooth position was 2.46 ± 1.25 mm. The mesiodistal deviation of the autotransplanted teeth was 1.63 ± 0.96 mm. CONCLUSIONS: The autotransplantation of single-rooted teeth with custom-designed and 3D-printed surgical tooling provided promising results. The technique was able to create surgically prepared sockets that could accommodate transplanted teeth in mandibles.


Assuntos
Impressão Tridimensional , Cirurgia Assistida por Computador , Humanos , Transplante Autólogo/métodos , Desenho Assistido por Computador , Mandíbula/diagnóstico por imagem , Mandíbula/cirurgia , Osteotomia , Tomografia Computadorizada de Feixe Cônico/métodos , Cirurgia Assistida por Computador/métodos , Cadáver
10.
Injury ; 54(1): 214-222, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35948510

RESUMO

INTRODUCTION: Prompt and effective hemorrhage control is paramount to improve survival in patients with catastrophic bleeding. In the ever-expanding field of bleeding control techniques, there is a need for a realistic training model to practice these life-saving skills. This study aimed to create a realistic perfused post-mortem human specimen (PMHS) flow model that is suitable for training various bleeding control techniques. MATERIALS AND METHODS: This laboratory study was conducted in the SkillsLab & Simulation Center of Erasmus MC, University Medical Center Rotterdam, the Netherlands. One fresh frozen and five AnubiFiX® embalmed PMHS were used for the development of the model. Subsequent improvements in the exact preparation and design of the flow model were made based on model performance and challenges that occurred during this study and are described. RESULTS: Circulating arteriovenous flow with hypertonic saline was established throughout the entire body via inflow and outflow cannulas in the carotid artery and jugular vein of embalmed PMHS. We observed full circulation and major hemorrhage could be mimicked. Effective bleeding control was achieved by placing a resuscitative endovascular balloon occlusion of the aorta (REBOA) catheter in the model. Regional perfusion significantly reduced the development of tissue edema. CONCLUSION: Our perfused PMHS model with circulating arterial and venous flow appears to be a feasible method for the training of multiple bleeding control techniques. Regional arteriovenous flow successfully reduces tissue edema and increases the durability of the model. Further research should focus on reducing edema and enhancing the durability of the model.


Assuntos
Oclusão com Balão , Procedimentos Endovasculares , Humanos , Oclusão com Balão/métodos , Cadáver , Hemorragia/terapia , Aorta , Países Baixos , Ressuscitação/métodos
11.
Clin Oral Implants Res ; 34(2): 116-126, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36458928

RESUMO

BACKGROUND: The fixture thread depth reportedly influences the primary stability of dental implant, but its effect on the positional accuracy in immediate implant placement has not been reported previously. MATERIALS AND METHODS: Fifty-six single-rooted, anterior and premolar teeth were extracted from six human cadavers, followed by installing either regular-threaded implants (RT group, N = 30) or deep-threaded implants (DT group, N = 26) completely relying on the surgical guide. Optical impressions taken after osteotomy and fixture installation were superimposed with the preoperative virtual planning data to measure the vertical, angular, platform and apex deviations that occurred during osteotomy and installation. RESULTS: While the osteotomy deviations were similar between the two groups, the angular and apex deviation of the DT group (2.67 ± 2.56°; 1.04 ± 0.49 mm, respectively) were significantly larger than those of the RT group (1.61 ± 1.04°; 0.67 ± 0.41 mm, respectively) during installation (p < .05). When the installation deviations were analysed in the anterior and premolar areas separately, the angular, platform and apex deviations of the DT group (3.05 ± 3.26°; 0.75 ± 0.32 mm; 1.08 ± 0.56 mm, respectively) were significantly larger than those of the RT group (1.56 ± 0.73°, 0.59 ± 0.28 mm; 0.62 ± 0.38 mm, respectively) in the anterior site (p < .05), whereas there was no significant intergroup difference in the premolar site. CONCLUSION: In immediate-implant surgery, using an implant with a deeper thread might increase the deviations during installation, especially in the anterior area.


Assuntos
Implantes Dentários , Cirurgia Assistida por Computador , Humanos , Implantação Dentária Endóssea , Tomografia Computadorizada de Feixe Cônico , Cadáver , Desenho Assistido por Computador , Imageamento Tridimensional
12.
Anat Sci Int ; 98(1): 147-150, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36197651

RESUMO

Superficial palmar arch (SPA) is a dominant vascular structure in the palmar region that provides a major blood supply to fingers. Present case describes a rare formation and branching pattern of SPA in a formalin fixed cadaveric left hand. In this case, SPA was formed by the anastomoses between radial artery (RA) and the superficial brachioulnar artery (SBUA), which is defined as an ulnar artery with a high origin in the arm. More interestingly, unlike classic literature, SPA sends out six branches instead of four, and the principle artery of thumb arises directly from SPA instead of RA. The aforementioned variations have rarely been reported in previous literature and demonstrate important clinical significance for accidental intra-arterial injections, errors in blood pressure readings, as well as orthopedic, plastic and vascular surgeries of the upper limbs.


Assuntos
Mãos , Artéria Ulnar , Humanos , Mãos/irrigação sanguínea , Extremidade Superior , Polegar , Artéria Radial , Cadáver
13.
Am J Sports Med ; 50(11): 2953-2960, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35914183

RESUMO

BACKGROUND: The optimal graft choice between the bone-patellar tendon-bone (BPTB) and the quadriceps tendon remains controversial. Studies evaluating the microscopic anatomy of the quadriceps tendon-patellar bone (QTB) and BPTB grafts for anterior cruciate ligament (ACL) reconstruction are currently lacking. HYPOTHESIS: The relationship between post-ACL reconstruction graft bending angle (GBA) and the angle corresponding to the GBA (cGBA) would indicate that the BPTB can bend more than the QTB at the femoral tunnel aperture. STUDY DESIGN: Controlled laboratory study. METHODS: Twenty paired human cadaveric knees fixed at <10° of knee joint flexion (mean age, 82.5 years) underwent histological sectioning and staining with Masson trichrome and toluidine blue. The femoral ACL insertion, QTB graft, and BPTB graft were microscopically analyzed. The width of the direct insertion, thickness of the uncalcified fibrocartilage and calcified fibrocartilage, ligament attachment angle, and cGBA for each group were measured. Eighteen patients who underwent ACL reconstruction with QTB or BPTB autograft were included for the evaluation of GBA using computed tomography images at 1 week postoperatively. RESULTS: The mean insertion widths of the femoral ACL, QTB, and BPTB were 7.81, 9.07, and 6.54 mm, respectively. The QTB was 16% wider than the ACL, while the BPTB was 16% narrower than the ACL. The mean insertion thicknesses of the femoral ACL, QTB, and BPTB were 0.53, 0.94, and 0.38 mm, respectively. The QTB was 77% thicker than the ACL (P < .001), while the BPTB was 28% thinner than the ACL (P = .017). The mean ligament attachment angles of the femoral ACL, QTB, and BPTB were 20.3°, 30.2°, and 33.3°, respectively, and the QTB and the BPTB were 49% and 64% larger, respectively, than the ACL. The mean cGBAs of the femoral ACL, QTB, and BPTB were 33.9°, 35.1°, and 12.3°, respectively. The BPTB was 64% smaller than the ACL, while there was no significant difference between the QTB and the ACL. The mean GBA was 57.7°. CONCLUSION: The insertion width and thickness were significantly greater and smaller in the QTB and BPTB grafts, respectively, than in the ACL. The relationship between GBA after ACL reconstruction and cGBA in knee extension indicates that at the femoral tunnel aperture, the BPTB can bend more than the QTB. CLINICAL RELEVANCE: QTB graft may allow more anatomic ACL reconstruction to be performed.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Ligamento Patelar , Idoso de 80 Anos ou mais , Ligamento Cruzado Anterior/cirurgia , Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Cadáver , Humanos , Ligamento Patelar/cirurgia
14.
Surg Radiol Anat ; 44(9): 1277-1280, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35960349

RESUMO

PURPOSE: Our goal was to investigate the cases of bilateral aplasia of the anterior cerebral artery (ACA). METHODS: The macro- and microdissection of the target human brain arteries of 388 cadaveric cases was applied under the magnifying glass. Each case was photographed and diagrammatically represented in the workbook. The length and the outer diameter of the corresponding arteries on the photos were measured using a computer software program. RESULTS: There was only one case (1/388 or 0.25%) of bilateral ACA aplasia that belonged to a male adult cadaver. Except for the variations of the posterior communicating artery on one side and the basilar artery, the instance of cerebral pathology was not recorded in this case. We compared the recent case with available literature cases. CONCLUSION: Summarizing small number of literature cases, the recent case of bilateral ACA aplasia as the fifth case discovered so far, represents a true morphological rarity.


Assuntos
Artéria Cerebral Anterior , Círculo Arterial do Cérebro , Adulto , Artéria Cerebral Anterior/anormalidades , Artéria Cerebral Anterior/diagnóstico por imagem , Cadáver , Humanos , Masculino
15.
Pacing Clin Electrophysiol ; 45(9): 1056-1061, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35766651

RESUMO

INTRODUCTION: In this article we present the extraction of a Micra from a human cadaver implanted 3 years previously with both visual and X-ray imaging taken during the removal. METHODS: A Micra pacemaker was extracted from a human cadaver with endoscopy and fluoroscopy using a Micra delivery tool. Histological analysis was performed on slices from the tissue surrounding the Micra. RESULTS: The fully encapsulated Micra was easily retrieved with a maximum force of 1.9 pounds. CONCLUSIONS: Even though the Micra was implanted almost 3 years previously, the snaring and extraction of the Micra was performed relatively easily and with minimal force required.


Assuntos
Marca-Passo Artificial , Cadáver , Fluoroscopia , Humanos , Implantação de Prótese/métodos
16.
Int. j. morphol ; 40(3): 750-754, jun. 2022. ilus
Artigo em Inglês | LILACS | ID: biblio-1385662

RESUMO

SUMMARY: The presented case characterizes an association of primitive and definitive arteries with variations on the cadaveric brain base of a very old man. This case is found by the retrospective review of the data archive obtained during many years of cooperation of the author and co-authors. Fenestration of the (ectatic) basilar artery, partial and total duplication of some cerebellar arteries was associated with other variations of the vertebrobasilar and carotid systems. Although this is a case autopsied because of the myocardial infarction, the peculiarity of the case lies in the absence of the aneurysm based on the fenestration or dissection of one of the cerebral arteries.


RESUMEN: El caso presentado caracteriza una asociación de arterias primitivas y definitivas con variaciones sobre la base cerebral cadavérica de un anciano. Este caso se encuentra mediante la revisión retrospectiva de datos obtenidos durante muchos años de un trabajo de cooperación del autor y coautores. La fenestración de la arteria basilar (ectásica), la duplicación parcial y total de algunas arterias cerebelosas se asoció con otras variaciones de los sistemas vertebrobasilar y carotídeo. Si bien se trata de un caso de autopsia a causa de un infarto del miocardio, la peculiaridad del caso radica en la ausencia del aneurisma en base a la fenestración o disección de una de las arterias cerebrales.


Assuntos
Humanos , Masculino , Idoso , Artéria Basilar/anormalidades , Artéria Vertebral/anormalidades , Encéfalo/irrigação sanguínea , Cadáver , Variação Anatômica
17.
Cell Tissue Bank ; 23(3): 591-606, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35277795

RESUMO

Management of peripheral nerve defects is a complicated problem in clinical contexts. Autologous nerve grafting, a gold standard for surgical treatment, has been well known to have several limitations, such as donor site morbidity, a limited amount of available donor tissue, and size mismatches. Acellular nerve allografts (ANAs) have been developed as an alternative and have been applied clinically with favorable outcomes. However, because of the limited availability of commercialized ANAs due to supplier-related issues and high costs, efforts continue to produce alternative sources for ANAs. The present study evaluated the anatomical and histological characteristics of human peripheral nerves using 25 donated human cadavers. The length, diameter, and branching points of various peripheral nerves (median, ulnar, tibial, lateral femoral cutaneous, saphenous, and sural nerves) in both the upper and lower extremities were evaluated. The cross-sectional area (CSA), ratio of fascicular area, and numbers of fascicles were also evaluated via histologic analysis. CSA, the ratio of fascicular area, and the number of fascicles were analyzed statistically in correlation with demographic data (age, sex, height, weight, BMI). The mean length of all evaluated nerves ranged from 17.1 to 41.4 cm, and the mean diameter of all evaluated nerves ranged from 1.2 to 4.9 mm. Multiple regression analysis revealed correlations between the ratio of fascicular area and sex (p = 0.005) and BMI (p = 0.024) (R2 = 0.051). The results of the present study will be helpful in selecting necessary nerve allograft sources while considering the characteristics of each nerve in the upper and lower extremities during ANAs production.


Assuntos
Transplante de Células-Tronco Hematopoéticas , Tecido Nervoso , Cadáver , Humanos , Nervos Periféricos/anatomia & histologia , Nervos Periféricos/transplante , Nervo Sural
18.
J Orthop Traumatol ; 23(1): 14, 2022 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-35286486

RESUMO

BACKGROUND: Standard supra-acetabular pin placement still needs fluoroscopic guidance, which is technically demanding for an untrained surgeon due to the unfamiliar fluoroscopic view and the risk of damaging some structures. The risks associated with the open technique without fluoroscopy have not yet been investigated, despite the palpable entry point and large bony corridor for rapid insertion in the limited time available for the management of unstable pelvic fracture patients. The aim of this study was to compare the open technique without fluoroscopy to the fluoroscopically assisted percutaneous technique for the positioning of supra-acetabular screws in cadavers without pelvic instability. MATERIALS AND METHODS: The open technique for half-pin placement was compared to standard fluoroscopic guidance in 16 hemipelves (8 cadavers). The open technique was first performed on one side in each cadaver after simple randomization, followed by standard fluoroscopic guidance on the other side. In the open technique group, a Schanz pin 5 mm in diameter and 200 mm in length was inserted in the area just above the anteroinferior iliac spine (AIIS) and aimed with a medial inclination of 20° and a cephalad inclination of 10-20° after a 2 cm pilot drill hole had been established. Standard fluoroscopically guided pin placement was performed on the other side. Fluoroscopic assessment was conducted after final pin placement on both sides. The lateral femoral cutaneous nerve of the thigh (LFCN) and the hip capsule were identified via the Smith-Peterson approach. After complete dissection of soft tissue, it was clearly apparent that pin penetration was conducted outside the bony corridor. RESULTS: The LFCN was found to be in a risk zone near the pin (mean distance, 15 mm; range, 0-30 mm). One LFCN may have been injured in the fluoroscopic guidance group. The mean medial inclination of the pin was 19.8° (range, 5-40°) and the mean cephalad inclination was 11.5° (range 0-20°) in the open technique group. The mean medial inclination of the pin was 30.4° (range, 20-45°) and the mean cephalad inclination was 19.3° (range, 2-35°) in the fluoroscopic guidance group. The mean distance of the pin entry point from the AIIS was 11.1 mm (range, 0-35 mm) in the open technique group. The mean distance of the entry point of the pin from the AIIS was 15.1 mm (range, 0-25 mm) in the fluoroscopic guidance group. The mean hip joint capsule distance was 12 mm (range, 8-25 mm). No joint penetration was observed in the open technique group, compared to one joint penetration in the fluoroscopic guidance group. No sciatic notch penetration was found in either group, but pin penetration outside the external cortex of the ilium was found only in the open technique group, in 4 hemipelves. CONCLUSIONS: This study shows that the freehand technique performed by experienced trauma surgeons may be as acceptable as controlled pin insertion under image intensification for selecting the proper entry point and stabilizing the anterior pelvic ring.


Assuntos
Fixadores Externos , Fixação de Fratura , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Pinos Ortopédicos , Cadáver , Fixação de Fratura/métodos , Humanos
19.
Med Sci Educ ; 32(1): 13-15, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35154891

RESUMO

Perimortem Cesarean section is a rare, time-sensitive, and invasive medical procedure. We describe a novel approach for high-fidelity training using a human cadaver with an inserted simulated gravid uterus.

20.
J Exp Orthop ; 8(1): 53, 2021 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-34296367

RESUMO

PURPOSE: The goal of this preliminary report was to show the use of novel Ultrasound (US) technology for anterior cruciate ligament (ACL) reconstruction surgery and evaluate its feasibility for the creation of a rectangular femoral bone tunnel during an arthroscopic procedure in a human cadaver model. METHODS: Two fresh frozen human cadaver knees were prepared for arthroscopic rectangular femoral tunnel completion using a prototype US device (OLYMPUS EUROPA SE & CO. KG). The desired rectangular femoral tunnel was intended to be located in the femoral anatomical ACL footprint. Its tunnel aperture was planned at 10 × 5 mm and a depth of 20 mm should be achieved. For one knee, the rectangular femoral tunnel was realized without a specific cutting guide and for the other with a 10 × 5 mm guide. One experienced orthopedic surgeon performed the two procedures consecutively. The time for femoral tunnel completion was evaluated. CT scans with subsequent three-dimensional image reconstructions were performed in order to evaluate tunnel placement and configuration. RESULTS: In the two human cadaver models the two 10 × 5x20mm rectangular femoral tunnels were successfully completed and located in the femoral anatomical ACL footprint without adverse events. The time for femoral tunnel completion was 14 min 35 s for the procedure without the guide and 4 min 20 s with the guide. CONCLUSION: US technology can be used for the creation of a rectangular femoral bone tunnel during an arthroscopic ACL reconstruction procedure. The use of a specific cutting guide can reduce the time for femoral tunnel completion. Additional experience will further reduce the time of the procedure.