Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 122
Filtrar
2.
J Immunol Methods ; 530: 113693, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38797276

RESUMO

BACKGROUND: Manufacturers and diagnostic companies often recommend on-site verification of analytical performance in the clinical laboratory. The validation process used by manufacturers is rarely described in detail, and certain information on analytical performance is missing from the product sheet, especially for immunoanalytical methods. We describe an approach to the detailed validation of an ELISA method for the measurement of proprotein convertase subtilisin/kexin type 9 (PCSK9) plasma concentrations. We compared manufacturers' claims of analytical performance with data obtained in the field laboratory using several approaches. METHODS: We used the Human Proprotein Convertase 9/PCSK9 Quantikine ELISA diagnostic kit (R&D systems, Bio-Techne Ltd., Abingdon Science Park, Abingdon, UK) and three levels of quality control solution Quantikine Immunoassay Control Group 235 (R&D systems, Bio-Techne Ltd., Abingdon Science Park, Abingdon, UK) to verify precision. We measured the concentration of PCSK9 using the DS2 ELISA Reader (Dynex Technologies GmbH, Denkendorf, Germany). We used analysis of variance (ANOVA) and the R statistical package (R core team, version 1.4.5). Statistical analysis and terminology were performed according to protocol CLSI EP15-A3, and the reference interval was checked according to CLSI/IFCC C28-A3c. RESULTS: We found a significant difference between the manufacturer's claims of analytical performance and real data measured in the routine clinical laboratory. The calculated CV (%) for repeatability (calculated by simple estimation of the mean and SD, as used by the manufacturer) was between 5.5% and 7.4%, but the manufacturer's claim was between 4.1% and 6.5%. Using ANOVA, the true repeatability was between 5.0% and 6.9%. Similarly, ANOVA revealed values of CV (%) for within-laboratory imprecision between 6.5% and 9.1%, while the manufacturer's claims were between 4.1% and 5.9%. The recovery ranged from 105.5% to 121.8%. The manufacturer's recommended reference interval was checked and we didn't find any significant difference between men and women. CONCLUSIONS: We describe a comprehensive approach to verify the analytical performance of an ELISA method using the measurement of PCSK9 plasma concentration as an example. We found differences between the results of this approach based on the CLSI EP15-A3 protocol and data provided by the manufacturer. We recommend the verification of analytical performance by more complex statistical tools in laboratory practice.


Assuntos
Ensaio de Imunoadsorção Enzimática , Pró-Proteína Convertase 9 , Humanos , Pró-Proteína Convertase 9/sangue , Pró-Proteína Convertase 9/imunologia , Ensaio de Imunoadsorção Enzimática/normas , Ensaio de Imunoadsorção Enzimática/métodos , Reprodutibilidade dos Testes , Feminino , Masculino , Kit de Reagentes para Diagnóstico/normas , Controle de Qualidade
3.
Clin Chem Lab Med ; 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38801528

RESUMO

OBJECTIVES: This study performed an analytical validation study of the Mindray high-sensitivity cardiac troponin I (hs-cTnI) assay addressing limit of blank (LoB), limit of detection (LoD), precision, linearity, analytical specificity and sex-specific 99th percentile upper reference limits. METHODS: LoB, LoD, precision, linearity and analytical specificity were studied according to Clinical and Laboratory Standards Institute. We used one reagent lot and one CL1200i analyzer. Skeletal troponin I and T, cardiac troponin T, troponin C, actin, tropomyosin, myosin light chain, myoglobin and creatine kinase (CK-MB) were studied for cross-reactivity. Interference with biotin was examined. Lithium heparin samples (one freeze thaw cycle) from healthy males and females were measured to determine the 99th percentiles by using the non-parametric method. Analyses were performed before and after excluding subjects with clinical conditions and/or increased surrogate biomarkers. RESULTS: The Mindray hs-cTnI assay met criteria to be considered as a hs-cTn assay. LoB and LoD was <0.1 ng/L and 0.1 ng/L, respectively. Repeatability had a coefficient of variation 1.2-3.8 %, and within-laboratory imprecision 1.7-5.0 %. The measuring interval ranged from 1.1 to 28,180 ng/L. The analytical specificity was clinically acceptable for the interferents studied. After exclusions, the 99th percentile URLs obtained were 10 ng/L overall, 5 ng/L for females and 12 ng/L for males. CONCLUSIONS: Analytical observations of the Mindray hs-cTnI assay demonstrated excellent LoB, LoD, precision, linearity and analytical specificity, that were in alignment with the manufacturer's claims and regulatory guidelines for hs-cTnI. The assay is suitable for clinical investigation for patient-oriented studies.

4.
J Clin Epidemiol ; 165: 111189, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38613246

RESUMO

OBJECTIVES: To provide guidance on rating imprecision in a body of evidence assessing the accuracy of a single test. This guide will clarify when Grading of Recommendations Assessment, Development and Evaluation (GRADE) users should consider rating down the certainty of evidence by one or more levels for imprecision in test accuracy. STUDY DESIGN AND SETTING: A project group within the GRADE working group conducted iterative discussions and presentations at GRADE working group meetings to produce this guidance. RESULTS: Before rating the certainty of evidence, GRADE users should define the target of their certainty rating. GRADE recommends setting judgment thresholds defining what they consider a very accurate, accurate, inaccurate, and very inaccurate test. These thresholds should be set after considering consequences of testing and effects on people-important outcomes. GRADE's primary criterion for judging imprecision in test accuracy evidence is considering confidence intervals (i.e., CI approach) of absolute test accuracy results (true and false, positive, and negative results in a cohort of people). Based on the CI approach, when a CI appreciably crosses the predefined judgment threshold(s), one should consider rating down certainty of evidence by one or more levels, depending on the number of thresholds crossed. When the CI does not cross judgment threshold(s), GRADE suggests considering the sample size for an adequately powered test accuracy review (optimal or review information size [optimal information size (OIS)/review information size (RIS)]) in rating imprecision. If the combined sample size of the included studies in the review is smaller than the required OIS/RIS, one should consider rating down by one or more levels for imprecision. CONCLUSION: This paper extends previous GRADE guidance for rating imprecision in single test accuracy systematic reviews and guidelines, with a focus on the circumstances in which one should consider rating down one or more levels for imprecision.


Assuntos
Abordagem GRADE , Processos Grupais , Humanos , Julgamento , Tamanho da Amostra
5.
J Trace Elem Med Biol ; 84: 127451, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38636293

RESUMO

BACKGROUND: This study examines the imprecision of zinc (Zn) measurements across various clinical detection methods by analyzing the external quality assessment (EQA) data from 2018 to 2022. The findings of this study aim to offer recommendations for enhancing Zn measurements. METHODS: Participating laboratories were grouped into peer categories based on the detection methods. The robust mean and coefficient of variation (CV) of the samples were calculated following ISO 13528 guidelines. The evaluation criteria for optimal, desirable, and minimum allowable imprecision in Zn estimation are 2.50%, 5.05%, and 7.55%, respectively, based on biological variation. Furthermore, the study examined inter-lab CVs, inter-method bias, and the passing rate. The impact of sample concentration on CVs and the pass rate was also investigated. RESULTS: Over the past five years, 4283 laboratories participated in the EQA program, showing a high pass rate that improved as sample concentration increased. Differential pulse polarography (DPP) demonstrated stable and low CVs (0.61-1.86%). Although differential pulse stripping (DPS) was less stable than DPP, it still exhibited a low CV (0.71-3.10%). Graphite furnace atomic absorption spectrometry (GFAAS) and flame atomic absorption spectrometry (FAAS) performed similarly and displayed stable CVs (2.39-4.42%) within the acceptable range of desirable imprecision (5.05%). However, the CVs for ICP-MS were unacceptable in three out of the five years (5.28-6.20%). In 2022, the number of participating laboratories for DDP, DPS, GFAAS, FAAS and ICP-MS is 131, 35, 35, 820 and 72, respectively. CONCLUSION: This study provides reliable insights into the imprecision of Zn measurements in clinical laboratories. The findings indicate that additional efforts are required to reduce the imprecision of ICP-MS in Zn measurements.


Assuntos
Zinco , Zinco/análise , China , Humanos , Controle de Qualidade
6.
J Med Biochem ; 43(1): 43-49, 2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38496028

RESUMO

Background: Six Sigma is a popular quality management system that enables continuous monitoring and improvement of analytical performance in the clinical laboratory. We aimed to calculate sigma metrics and quality goal index (QGI) for 17 biochemical analytes and compare the use of bias from internal quality control (IQC) and external quality assurance (EQA) data in the calculation of sigma metrics. Methods: This retrospective study was conducted in Marmara University Pendik E&R Hospital Biochemistry Laboratory. Sigma metrics calculation was performed as (TEa-bias)/CV). CV was calculated from IQC data from June 2018 - February 2019. EQA bias was calculated as the mean of % deviation from the peer group means in the last seven surveys, and IQC bias was calculated as (laboratory control result mean-manufacturer control mean)/ manufacturer control mean) x100. In parameters where sigma metrics were <5; QGI=bias/1.5 CV) score of <0.8 indicated imprecision, >1.2 pointed inaccuracy, and 0.8-1.2 showed both imprecision and inaccuracy. Results: Creatine kinase (both levels), iron and magnesium (pathologic levels) showed an ideal performance with ≥6 sigma level for both bias determinations. Eight of the 17 parameters had different sigma levels when we compared sigma values calculated from EQA and IQC derived bias% while the rest were grouped at the same levels. Conclusions: Sigma metrics is a good quality tool to assess a laboratory's analytical performance and facilitate the comparison of the assay performances in the same manner across multiple systems. However, we might need to design a tight internal quality control protocol for analytes showing poor assay performance.

7.
Clin Chem Lab Med ; 62(8): 1505-1511, 2024 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-38353157

RESUMO

ISO 15189 requires laboratories to estimate the uncertainty of their quantitative measurements and to maintain them within relevant performance specifications. Furthermore, it refers to ISO TS 20914 for instructions on how to estimate the uncertainty and what to take into consideration when communicating uncertainty of measurement with requesting clinicians. These instructions include the responsibility of laboratories to verify that bias is not larger than medically significant. If estimated to be larger than acceptable, such bias first needs to be eliminated or (temporarily) corrected for. In the latter case, the uncertainty of such correction becomes part of the estimation of the total measurement uncertainty. If small enough to be acceptable, bias becomes part of the long term within laboratory random variation. Sources of possible bias are (not limited to) changes in reagent or calibrator lot variation or calibration itself. In this paper we clarify how the rationale and mathematics from an EFLM WG ISO/A position paper on allowable between reagent lot variation can be applied to calculate whether bias can be accepted to become part of long-term imprecision. The central point of this rationale is to prevent the risk that requesting clinicians confuse changes in bias with changes in the steady state of their patients.


Assuntos
Viés , Humanos , Incerteza , Calibragem , Técnicas de Laboratório Clínico/normas
8.
Clin Biochem ; 125: 110731, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38360198

RESUMO

BACKGROUND: An analytical benchmark for high-sensitivity cardiac troponin (hs-cTn) assays is to achieve a coefficient of variation (CV) of ≤ 10.0 % at the 99th percentile upper reference limit (URL) used for the diagnosis of myocardial infarction. Few prospective multicenter studies have evaluated assay imprecision and none have determined precision at the female URL which is lower than the male URL for all cardiac troponin assays. METHODS: Human serum and plasma matrix samples were constructed to yield hs-cTn concentrations near the female URLs for the Abbott, Beckman, Roche, and Siemens hs-cTn assays. These materials were sent (on dry ice) to 35 Canadian hospital laboratories (n = 64 instruments evaluated) participating in a larger clinical trial, with instructions for storage, handling, and monthly testing over one year. The mean concentration, standard deviation, and CV for each instrument type and an overall pooled CV for each manufacturer were calculated. RESULTS: The CVs for all individual instruments and overall were ≤ 10.0 % for two manufacturers (Abbott CVpooled = 6.3 % and Beckman CVpooled = 7.0 %). One of four Siemens Atellica instruments yielded a CV > 10.0 % (CVpooled = 7.7 %), whereas 15 of 41 Roche instruments yielded CVs > 10.0 % at the female URL of 9 ng/L used worldwide (6 cobas e411, 1 cobas e601, 4 cobas e602, and 4 cobas e801) (CVpooled = 11.7 %). Four Roche instruments also yielded CVs > 10.0 % near the female URL of 14 ng/L used in the United States (CVpooled = 8.5 %). CONCLUSIONS: The number of instruments achieving a CV ≤ 10.0 % at the female 99th-percentile URL varies by manufacturer and by instrument. Monitoring assay precision at the female URL is necessary for some assays to ensure optimal use of this threshold in clinical practice.


Assuntos
Infarto do Miocárdio , Humanos , Masculino , Feminino , Estudos Prospectivos , Canadá , Infarto do Miocárdio/diagnóstico , Bioensaio , Troponina , Troponina T , Biomarcadores , Valores de Referência
9.
Vet Clin Pathol ; 53 Suppl 1: 86-95, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38238987

RESUMO

BACKGROUND: Analytical performance specifications (APS) are vital for method evaluation and quality control validation. However, the limited availability of biological variation (BV) data, regulatory guidelines, and expert opinion (EO) may present challenges in veterinary medicine. The empirical biological variation (EBV) approach, based on population reference intervals (pRI), has emerged as an alternative method to derive APS in human medicine. OBJECTIVES: This study aimed to assess the practicality and usefulness of the EBV approach in deriving performance limits for various measurands in dogs and cats. METHODS: Eight hematology and 13 biochemistry measurands were analyzed in dogs and cats. Estimates of combined biologic variation based on traditional biological (CVB ) and EBV-derived (CVE *) formulas were calculated and assessed for evidence of correlation. Performance limits for expanded uncertainty/total error and imprecision were compared among EO, BV, and EBV. RESULTS: Strong and significant correlations were found between CVB and CVE * for both dogs (r = .86, p < .00001) and cats (r = 0.95, p < .00001). The EBV-derived APS were generally comparable to EO and BV, with a subjective criterion of 1.5% difference for imprecision and 3% for total error/expanded uncertainty. CONCLUSION: The EBV approach, using pRI, shows promise as a surrogate marker for biological variation and as a practical tool for determining performance limits in dogs and cats. Assuming accurate pRI generated on analyzers with stable analytical performance, this approach could offer benefits when expert recommendations or robust BV studies are lacking or yield conflicting results. Further research is needed to explore the applicability and advantages of the EBV in veterinary medicine.


Assuntos
Doenças do Gato , Doenças do Cão , Hematologia , Humanos , Gatos , Animais , Cães , Laboratórios Clínicos , Controle de Qualidade
10.
Cardiovasc Ultrasound ; 22(1): 1, 2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38169399

RESUMO

BACKGROUND: Serial echocardiographic assessments are common in clinical cardiology, e.g., for timing of intervention in mitral and aortic regurgitation. When following patients with serial echocardiograms, each new measurement is a combination of true change and confounding noise. The current investigation compares linear chamber dimensions with volume estimates of chamber size. The aim is to assess which measure is best for serial echocardiograms, when the ideal parameter will be sensitive to change in chamber size and have minimal spurious variation (noise). We present a method that disentangles true change from noise. Linear regression of chamber size against elapsed time gives a slope, being the ability of the method to detect change. Noise is the scatter of individual points away from the trendline, measured as the standard error of the slope. The higher the signal-to-noise ratio (SNR), the more reliably a parameter will distinguish true change from noise. METHODS: LV and LA parasternal dimensions and apical biplane volumes were obtained from serial clinical echocardiogram reports. Change over time was assessed as the slope of the linear regression line, and noise was assessed as the standard error of the regression slope. Signal-to-noise ratio is the slope divided by its standard error. RESULTS: The median number of LV studies was 5 (4-11) for LV over a mean duration of 5.9 ± 3.0 years in 561 patients (diastole) and 386 (systole). The median number of LA studies was 5 (4-11) over a mean duration of 5.3 ± 2.0 years in 137 patients. Linear estimates of LV size had better signal-to-noise than volume estimates (p < 0.001 for diastolic and p = 0.035 for systolic). For the left atrium, the difference was not significant (p = 0.214). This may be due to sample size; the effect size was similar to that for LV systolic size. All three parameters had a numerical value of signal-to-noise that favoured linear dimensions over volumes. CONCLUSION: Linear measures of LV size have better signal-to-noise than volume measures. There was no difference in signal-to-noise between linear and volume measures of LA size, although this may be a Type II error. The use of regression lines may be better than relying on single measurements. Linear dimensions may clarify whether changes in volumes are real or spurious.


Assuntos
Apêndice Atrial , Ventrículos do Coração , Humanos , Ventrículos do Coração/diagnóstico por imagem , Átrios do Coração/diagnóstico por imagem , Ecocardiografia/métodos , Função Ventricular Esquerda , Volume Sistólico
11.
Ann Lab Med ; 44(3): 245-252, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38014482

RESUMO

Background: Clinical chemistry tests are most widely used in clinical laboratories, and diverse measurement systems for these analyses are available in China. We evaluated the imprecision of clinical chemistry measurement systems based on internal QC (IQC) data. Methods: IQC data for 27 general chemistry analytes were collected in February each year from 2013 to 2022. Four performance specifications were used to calculate pass rates for CVs of IQC data in 2022. Boxplots were drawn to analyze trends of CVs, and differences in CVs among different groups were assessed using the Mann-Whitney U-test or Kruskal-Wallis test. Results: The number of participating laboratories increased significantly from 1,777 in 2013 to 5,425 in 2022. CVs significantly decreased for all 27 analytes, except creatine kinase and lipase. Triglycerides, total bilirubin, direct bilirubin, iron, and γ-glutamyl transferase achieved pass rates >80% for all goals. Nine analytes with pass rates <80% based on 1/3 allowable total error were further analyzed; the results indicated that closed systems exhibited lower CVs than open systems for all analytes, except total protein. For all nine analytes, differences were significant between tertiary hospitals and non-tertiary hospitals and between accredited and non-accredited laboratories. Conclusions: The CVs of IQC data for clinical chemistry have seen a continuous overall improvement in China. However, there is ample room for imprecision improvement for several analytes, with stricter performance specifications.


Assuntos
Serviços de Laboratório Clínico , Laboratórios , Humanos , Controle de Qualidade , Testes de Química Clínica , Bilirrubina , China , Química Clínica
12.
Am J Clin Pathol ; 161(1): 4-8, 2024 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-37769333

RESUMO

OBJECTIVES: An increase in analytical imprecision and/or the introduction of bias can affect the interpretation of quantitative laboratory results. In this study, we explore the impact of varying assay imprecision and bias introduction on the classification of patients based on fixed thresholds. METHODS: Simple spreadsheets (Microsoft Excel) were constructed to simulate conditions of assay deterioration, expressed as coefficient of variation and bias (in percentages). The impact on patient classification was explored based on fixed interpretative limits. A combined matrix of imprecision and bias of 0%, 2%, 4%, 6%, 8%, and 10% (tool 1) as well as 0%, 2%, 5%, 10%, 15%, and 20% (tool 2) was simulated, respectively. The percentage of patients who were reclassified following the addition of simulated imprecision and bias was summarized and presented in tables and graphs. RESULTS: The percentage of patients who were reclassified increased with increasing/decreasing magnitude of imprecision and bias. The impact of imprecision lessens with increasing bias such that at high biases, the bias becomes the dominant cause for reclassification. CONCLUSIONS: The spreadsheet tools, available as Supplemental Material, allow laboratories to visualize the impact of additional analytical imprecision and bias on the classification of their patients when applied to locally extracted historical results.


Assuntos
Viés , Pacientes , Humanos , Laboratórios , Pacientes/classificação
13.
J Vet Intern Med ; 37(5): 1794-1805, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37565515

RESUMO

BACKGROUND: Stability of serum symmetric dimethylarginine (sSDMA) during short- and long-term storage has not been assessed for the immunoassay of the Point-of-Care IDEXX Catalyst DX (POC) analyzer and the Enzyme Multiplied Immunoassay Technique of IDEXX commercial laboratory (CL). Also, the agreement between both analyzers is questioned. OBJECTIVES: To determine (a) the effect of storage time and temperature on sSDMA measured by POC and CL; (b) the agreement between sSDMA measured by POC and CL; and (c) the imprecision of the POC. ANIMALS: Serum of cats (n = 17) and dogs (n = 18) with a range of SDMA concentrations (6 to >100 µg/dL). METHODS: Based on an equivalence trial with predefined equivalence range (-3.0 to +3.0 µg/dL) and using T0 as baseline, stability was evaluated after 24 hours at 22°C and 4°C (POC); after 7 days at 4°C (POC and CL) and after 10 and 24 months at -24°C and -80°C (CL). Bland-Altman plots enabled method comparison. Imprecision of the POC was assessed by duplicate sSDMA measurements at T0. RESULTS: The POC analyzer produced equivalent sSDMA measurements if samples were stored for 24 hours at 4°C (95% confidence interval [CI]: -2.5-2.0 µg/dL), but not when stored for 24 hours at room temperature (RT; 95% CI: -4.1 to 0.5 µg/dL) or after 7 days at 4°C (95% CI: -3.6-1.0 µg/dL). The CL analyzer was less affected by preanalytical variation with clinically similar results obtained when samples were stored for 7 days at 4°C (95% CI: -2.2 to 2.4 µg/dL) and for at least 24 months at -24°C (95% CI: -1.7 to 2.9 µg/dL) and -80°C (95% CI: -1.5 to 3 µg/dL). A relevant mean difference of -2.3 µg/dL between both analyzers was found. Duplicate POC measurements were equivalent (95% CI: -2.6 to 2.0 µg/dL). CONCLUSIONS: Delayed analysis may significantly change sSDMA depending on storage and measurement conditions. Interchangeable use of assays should be done with caution because analytical variation could be interpreted as clinically relevant change.


Assuntos
Arginina , Sistemas Automatizados de Assistência Junto ao Leito , Gatos , Cães , Animais , Temperatura , Imunoensaio/veterinária
14.
J Mass Spectrom Adv Clin Lab ; 29: 16-20, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37502392

RESUMO

Introduction: Engaging pipetting events were developed to assess and challenge technicians' practical sample handling using matrices common to the clinical laboratory. As correct pipetting stands as a prerequisite for accurate clinical laboratory testing, this helped to understand sources of imprecision and bias attributed to the underlying step of aspirating and dispensing patient samples and internal standard in clinical LC-MS/MS assays while highlighting the importance for the clinical laboratory to evaluate this source of variability on an on-going basis and mitigate its impact. Methods: The events involved pipetting water, methanol, serum, and whole blood. Gravimetric analysis was used to determine the exact volumetric delivery of each matrix using two different techniques. Imprecision and bias were calculated based on the volume derived from the mass and density of each matrix, using literature values for each matrix type. Results: Low imprecision and bias were observed when pipetting water, as in common commercial pipetting assessment programs. Significantly increased imprecision and bias were observed in more applicable matrices (i.e., serum, whole blood, and methanol), indicating that water-based pipetting proficiency assessment leads to a false sense of technical ability. Additionally, the events within illuminated areas for training, leading to improved imprecision and bias. It was shown that pre-rinsing (aspirating and dispensing matrix three times to coat the tip) improved bias, particularly for delivery of methanol and whole blood. Conclusions: Precise and accurate pipetting within the clinical laboratory should not be taken for granted, nor implicitly inferred from proficiency assessment using aqueous solutions. The engaging and collegial events fostered training opportunities. Assay-specific patient sample delivery considerations (pipets and matrices) can inform the practicality of these events - the Pipetting Olympics - and drive improvements within the laboratory.

15.
Clin Chim Acta ; 546: 117391, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37196897

RESUMO

BACKGROUND: Over the past decade the use of LC-MS/MS has increased significantly in the hospital laboratories. Clinical laboratories have switched from immunoassays to LC-MS/MS methods due to the promise of improvements in sensitivity and specificity, better standardization with often non-commutable international standards, and better between-laboratory comparison. However, it remains unclear whether routine performance of the LC-MS/MS methods have met these expectations. METHOD: This study examined the EQAS results, from the Dutch SKML, of serum cortisol, testosterone, 25OH-vitaminD and cortisol in urine and saliva over 9 surveys (2020 to first half of 2021). RESULTS: The study found a significant increase in the number of compounds and in the number of results measured in the different matrices, with LC-MS/MS over a period of eleven years. In 2021, approximately 4000 LC-MS/MS results were submitted (serum: urine: saliva = 58:31:11%) compared to only 34 in 2010. When compared to the individual immunoassays, the LC-MS/MS based methods for serum cortisol, testosterone and 25OH-vitaminD showed comparable but also higher between-laboratory CVs in different samples of the surveys. For cortisol, testosterone and 25OH-vitaminD the median CV was 6.8%, 6.1% and 4.7% respectively for the LC-MS/MS compared to 3.9-8.0%,4.5-6.7%, and 7.5-18.3% for immunoassays. However, the bias and imprecision of the LC-MS/MS was better than that of the immunoassays. CONCLUSION: Despite the expectation that LC-MS/MS methods would result in smaller between-laboratory differences, as they are relatively matrix independent and better to standardize, the results of the SKML round robins do not reflect this for some analytes and may be in part explained by the fact that in most cases laboratory developed tests were used.


Assuntos
Hidrocortisona , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida/métodos , Química Clínica , Testosterona
16.
Clin Chem Lab Med ; 61(8): 1455-1462, 2023 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-36866730

RESUMO

OBJECTIVES: Except for the large bias of some measurement systems for serum cystatin C (CysC) measurements, unacceptable imprecision has been observed for the heterogenous system. This study analyzed the external quality assessment (EQA) results in 2018-2021 to provide an insight into the imprecision of CysC assays. METHODS: Five EQA samples were sent to participating laboratories every year. Participants were divided into reagent/calibrator-based peer groups, for which the robust mean of each sample and robust coefficient of variation (CV) were calculated by Algorithm A from ISO 13528. Peers with more than 12 participants per year were selected for further analysis. The limit of CV was determined to be 4.85% based on clinical application requirements. The concentration-related effect on CVs was investigated using logarithmic curve fitting; the difference in medians and robust CVs between instrument-based subgroups was also evaluated. RESULTS: The total number of participating laboratories increased from 845 to 1,695 in four years and heterogeneous systems remained the mainstream (≥85%). Of 18 peers with ≥12 participants, those using homogeneous systems showed relatively steady and small CVs over four years, with the mean four-year CVs ranging from 3.21 to 3.68%. Some peers using heterogenous systems showed reduced CVs over four years, while 7/15 still had unacceptable CVs in 2021 (5.01-8.34%). Six peers showed larger CVs at the low or high concentrations, and some instrument-based subgroups presented greater imprecision than others. CONCLUSIONS: More efforts should be made to improve the imprecision of heterogeneous systems for CysC measurement.


Assuntos
Cistatina C , Humanos , Testes de Função Renal
17.
Cureus ; 15(1): e34025, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36814748

RESUMO

BACKGROUND: High-dose methotrexate (HDMTX), defined as a dose greater than 500 mg/m2, is used to treat a variety of cancers; and though safe, it can cause major toxicity. Syva enzyme-multiplied immunoassay technique (EMIT) methotrexate (MTX) assay (Gurgaon, India: Siemens Healthcare Diagnostics Ltd.) uses a homogeneous enzyme immunoassay method. Low-end precision performances are very important for laboratory methods, especially when their results have clinical significance at these levels. METHODOLOGY: A total of 25 replicates (five replicates per run, for five runs) were analyzed for profiling. Precision, accuracy, linearity, limit of blank, limit of detection, and limit of quantification were determined using existing guidelines. Imprecision profile and limit of quantitation (LoQ) at 10% were determined by fitting data with hyperbolic regression. RESULTS: The coefficient of variation percentage (CV%) for low, mid, and high-level internal quality control (IQC) was 1.25%, 3.45%, and 1.55%, respectively. Similarly, estimated bias was -4.58%, -3.54%, -7.21% for each level. The assay linearity was maintained from a range of 0.041-1.993 mmol/L with an R2 of 0.959. The limit of detection was estimated to be 0.07 mmol/L. CONCLUSION: Syva EMIT MTX assay can be precisely and accurately used to measure low levels of serum methotrexate at levels lower than claimed by the manufacturer, aiding in the monitoring of toxicity in patients.

18.
Clin Chem Lab Med ; 61(5): 769-776, 2023 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-36420533

RESUMO

Lot-to-lot verification is an integral component for monitoring the long-term stability of a measurement procedure. The practice is challenged by the resource requirements as well as uncertainty surrounding experimental design and statistical analysis that is optimal for individual laboratories, although guidance is becoming increasingly available. Collaborative verification efforts as well as application of patient-based monitoring are likely to further improve identification of any differences in performance in a relatively timely manner. Appropriate follow up actions of failed lot-to-lot verification is required and must balance potential disruptions to clinical services provided by the laboratory. Manufacturers need to increase transparency surrounding release criteria and work closer with laboratory professionals to ensure acceptable reagent lots are released to end users. A tripartite collaboration between regulatory bodies, manufacturers, and laboratory medicine professional bodies is key to developing a balanced system where regulatory, manufacturing, and clinical requirements of laboratory testing are met, to minimize differences between reagent lots and ensure patient safety. Clinical Chemistry and Laboratory Medicine has served as a fertile platform for advancing the discussion and practice of lot-to-lot verification in the past 60 years and will continue to be an advocate of this important topic for many more years to come.


Assuntos
Química Clínica , Kit de Reagentes para Diagnóstico , Humanos , Controle de Qualidade , Laboratórios
19.
Artif Intell Rev ; 56(4): 3543-3617, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36092823

RESUMO

Havoc, brutality, economic breakdown, and vulnerability are the terms that can be rightly associated with COVID-19, for the kind of impact it is having on the whole world for the last two years. COVID-19 came as a nightmare and it is still not over yet, changing its form factor with each mutation. Moreover, each unpredictable mutation causes more severeness. In the present article, we outline a decision support algorithm using Generalized Trapezoidal Intuitionistic Fuzzy Numbers (GTrIFNs) to deal with various facets of COVID-19 problems. Intuitionistic fuzzy sets (IFSs) and their continuous counterparts, viz., the intuitionistic fuzzy numbers (IFNs), have the flexibility and effectiveness to handle the uncertainty and fuzziness associated with real-world problems. Although a meticulous amount of research works can be found in the literature, a wide majority of them are based mainly on normalized IFNs rather than the more generalized approach, and most of them had several limitations. Therefore, we have made a sincere attempt to devise a novel Similarity Measure (SM) which considers the evaluation of two prominent features of GTrIFNs, which are their expected values and variances. Then, to establish the superiority of our approach we present a comparative analysis of our method with several other established similarity methods considering ten different profiles of GTrIFNs. The proposed SM is then validated for feasibility and applicability, by elaborating a Fuzzy Multicriteria Group Decision Making (FMCGDM) algorithm and it is supportedby a suitable illustrative example. Finally, the proposed SM approach is applied to tackle some significant concerns due to COVID-19. For instance, problems like the selection of best medicine for COVID-19 infected patients; proper healthcare waste disposal technique; and topmost government intervention measures to prevent the COVID-19 spread, are some of the burning issues which are handled with our newly proposed SM approach.

20.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-995733

RESUMO

Objective:The allowable total error ( TEa),allowable imprecision ( CV)and allowable bias( Bias)were recommended for 34 routine chemistry analytes in China. Methods:According to the performance specification setting mode newly determined at the Milan conference in Italy,the performance specification was derived based on components biological variation (BV)and current state of the art mode. The data(including EQA data and IQC data)of laboratories participating in the routine chemistry and lipids and lipoproteins EQA activities of the national center for clinical laboratories from 2019 to 2021 was collected through clinet-EQA. For the analytes with biological variation(BV)data,compared the'percentage difference′ of EQA data and the'in-control coefficient of variation of the month′ of IQC data of each research analyte with the three levels evaluation criteria derived based on BV,and calculated the percentage difference passing rate and CV passing rate of all batches in each year. When the passing rate reaches 80%,the performance specifications of this level met the requirements of the recommended performance specifications of the analyte. For the analytes without BV data or analytes whose performance specifications at three levels derived based on BV could not be used as recommended standards,the recommended performance specifications are derived based on the current state of the art. After obtaining the recommended TEa and allowable CV for each analyte,used the formula | Bias|≤ TEa-z? CV to derive the recommended allowable bias. Results:The results of TEa ( CV)% recommended by 34 analytes are as follows:K4.7(2),Na4(1.5),Cl4(1.4),Ca5(2),P9.6(3.9),Glu6.4(2.5),Urea8(3),UA12(4.1),Cre11(3.3),TP5(2),Alb5.2(2.4),TC8.6(2.7),TG13.5(5),HDL-C16.5(4.3),LDL-C20.5(6.2),ApoAⅠ16(5.3),ApoB 17.1(5.5),Lp(a) 24.1(10.4),TBil 12.4(5),DBil 20(7.3),ALT16(5),AST13.5(4.8),ALP17.5(4.8),AMY13.1(3.3),CK11.3(3.8),LDH11(3.9),CHE13.4(5.3),LIP20(6.9),Fe13.3(5.2),Mg14(4.5),Cu17.9(6.8),Zn15.1(6.4),γ-GGT10(3.3),α-HBDH18(5.8).The formula | Bias|≤ TEa-z? CV is used to derive the allowable bias of 34 analytes. Conclusions:For 34 clinical routine chemistry quantitative analytes,the allowable total error,allowable imprecision and allowable bias that meet the current state of the art of Chinese laboratories are recommended.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...