Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.048
Filtrar
1.
Heliyon ; 10(12): e32721, 2024 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-38988561

RESUMO

Health problems and respiratory diseases are associated with poor indoor air ventilation. We investigated the air quality inside a classroom-laboratory where no ventilation is provided. The case of study, consisting of an internal enclosure, is located at the Escuela Técnica Superior de Edificación (ETSEM) of Madrid (Spain). The high height favours air stratification which is analysed in terms of temperature and CO2 spatial distribution. Temperature, air humidity, atmospheric pressure and CO2 concentration measurements were taken in time at three different height locations. A CFD numerical model was established to analyse air quality. Flow circulation is derived by solving full 3D Navier - Stokes governing equations, coupled with the thermal problem. The diffusion problem of the CO2 produced by the inner occupants is then derived from the kinematics solution. Three scenarios were taken into account: occupants seated (1), standing (2), half seated, half standing (3). Results clearly show the air stratification as a result of density gradient, which is in turn determined by temperature difference between the occupants and the surrounding air. Temperature prediction maximum relative error is contained to 3.5 %. As expected, CO2 concentration increases over time, reaching maximum values depending on the configuration considered and height location.

2.
Environ Res ; : 119586, 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-39002635

RESUMO

Exposure to 1-bromopropane (1-BP) is an emerging environmental and health concern due to its increasing environmental prevalence. Although the health effects of 1-BP exposure have been under-recognized, current evidence suggests the possibility of adverse pulmonary health effects due to 1-BP exposure. However, the association between 1-BP exposure and asthma prevalence remains unclear. Thus, we aimed to examine the association between 1-BP exposure and asthma prevalence in the general population. Using nationally representative data, we explored the potential impacts of indoor air quality (IAQ)-related behavioral factors on the level of 1-BP exposure. This study included 1,506 adults from the 2020-2021 Korea National Health and Nutrition Examination Survey. The prevalence of asthma was based on self-reported physician-diagnosed asthma. Urinary N-acetyl-S-(n-propyl)-L-cysteine (BPMA) levels were measured as a biomarker of 1-BP exposure, using high-performance liquid chromatography-mass spectrometry. Multiple logistic regression models were performed to investigate the associations between urinary BPMA metabolite and asthma prevalence after adjusting for potential confounders. Log-linear multiple regression models were used to examine the association between IAQ-related behavior and urinary BPMA concentration. Forty-seven individuals with asthma and 1,459 without asthma were included. Individuals in the highest quartile of urinary BPMA concentration had a 2.9 times higher risk of asthma than those in the lowest quartile (odds ratio [OR]: 2.85, 95% confidence interval [CI]: 1.02-7.98). The combination of natural and mechanical ventilation was associated with a reduced urinary BPMA concentration. Our findings suggest that 1-BP exposure is associated with the prevalence of asthma in adults and revealed higher urinary levels of BPMA in our study population compared to those in other countries. Given the emerging importance of IAQ, actively managing and modifying behavioral patterns to reduce 1-BP exposure in indoor environments could substantially attenuate the risk of asthma-related to 1-BP exposure.

3.
Sci Total Environ ; 947: 174432, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38960181

RESUMO

Bioaerosols control techniques, especially ultraviolet germicidal irradiation (UVGI) are gaining attention due to increasing needs for controlling of health risk caused by airborne biocontaminants. The effectiveness of a full-scale in-duct UVGI air disinfection system was investigated. One bacterium, a wild type Escherichia coli, and three fungal spores, Penicillium aragonense, Rhodotorula glutinis, and Cladosporium sp., were selected as test organisms and their inactivation under different conditions representative of a real application in HVAC systems were investigated. The results demonstrated that inactivation of airborne E. coli by the UVGI system was extremely effective, with >99.5 % of the input E. coli inactivated at a residence time lower than 0.36 s in the disinfection section. Airborne fungal spores were less susceptible to UV irradiation than E. coli. Under same conditions, viable counts reduction of P. aragonense, R. glutinis, and Cladosporium sp. spores were 53 %, 63 % and 73 %, respectively. The effect of UV light intensity, air flowrate and relative humidity were analyzed separately. A simplified model based on redefinition of the parameters in the classical inactivation kinetic equation was used to simulate the inactivation of airborne contaminants in the in-duct system under different conditions. The results showed that the simplified model was adequate to estimate disinfection efficacy of different bioaerosols by the UVGI system which could be useful for system design. Overall, this study shows that such in-duct UVGI systems can provide significant control of bioaerosols.

5.
Environ Int ; 190: 108873, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-39024827

RESUMO

Rapidly increasing urbanization in recent decades has elevated the subway as the primary public transportation mode in metropolitan areas. Indoor air quality (IAQ) inside subways is an important factor that influences the health of commuters and subway workers. This review discusses the subway IAQ in different cities worldwide by comparing the sources and abundance of particulate matter (PM2.5 and PM10) in these environments. Factors that affect PM concentration and chemical composition were found to be associated with the subway internal structure, train frequency, passenger volume, and geographical location. Special attention was paid to air pollutants, such as transition metals, volatile/semi-volatile organic compounds (VOCs and SVOCs), and bioaerosols, due to their potential roles in indoor chemistry and causing adverse health impacts. In addition, given that the IAQ of subway systems is a public health issue worldwide, we calculated the Gini coefficient of urban subway exposure via meta-analysis. A value of 0.56 showed a significant inequity among different cities. Developed regions with higher per capita income tend to have higher exposure. By reviewing the current advances and challenges in subway IAQ with a focus on indoor chemistry and health impacts, future research is proposed toward a sustainable urban transportation systems.

6.
Environ Pollut ; : 124555, 2024 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-39009298

RESUMO

Despite the global transition towards cleaner energy sources observed over the last decade, disparities in access to clean energy persist worldwide. The dependence on biomass for household heating exacerbates fuel poverty, as economically vulnerable households face challenges in obtaining certified firewood and often resort to using contaminated biomass as a substitute, either partially or completely. We examined black carbon (BC) particle concentrations -a marker for combustion- during wood stove operation through a five-day case study in a typical Chilean household. BC increased rapidly following the ignition of the stove, with the combustion of dry Eucalyptus globulus logs yielding a substantially lower peak (5.29 µg/m3) than when using unclean biomass: 35.75 µg/m3 with demolition wood and painted furniture, and 87.11 µg/m3 with the addition of a blend of particleboard with polystyrene foam. During the latter two events, BC particles remained indoors for about 20 h before the concentrations reverted to pre-spike levels. The slow decay in BC concentrations was further influenced by the infiltration of outdoor air. The mean indoor BC concentrations were comparable to or even exceeded those observed on busy roads in major cities worldwide. These results highlight the risks associated with limited access to clean fuels for indoor heating, alongside inadequate insulation. This study sheds light on the problem of fuel poverty and its adverse effects on health and well-being.

8.
J Sch Health ; 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38890148

RESUMO

BACKGROUND: The US government allocated over $2.5 billion in "Elementary and Secondary School Emergency Relief (ESSER)" funds to Washington State for COVID-19 response and ventilation improvements. Despite available funding, gaps persist in supporting schools to successfully use portable air cleaners (PACs). We evaluated PAC needs within King County, Washington and characterized factors influencing schools' purchase and use of PACs. METHODS: Public Health-Seattle & King County (PHSKC) assessed school's ventilation systems and IAQ improvements through a survey (N = 17). Separately, semi-structured interviews (N = 13) based on the technology acceptance model (TAM) were conducted with school personnel. A thematic analysis using inductive and deductive coding was conducted and logistic regression models assessed the predictive capability of the TAM. RESULTS: The PHSKC survey findings informed our recommendations. Positive attitudes, knowledge, and beliefs in ease of use and effectiveness of PACs were facilitators to PAC use. While barriers included a lack of training, education, and concerns about PAC maintenance and sustainability. TAM constructs of perceived usefulness (PU) and perceived ease of use (PEU) were predictive of having the intention to use PACs in schools. CONCLUSIONS: There is a critical need for solutions to circumvent challenges to implementing PACs in schools. This characterization provides insight for promoting PAC use in IAQ-impacted schools.

9.
Environ Health Insights ; 18: 11786302241259352, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38868365

RESUMO

Indoor exposure to outdoor pollutants adversely affects health, varying with building dimensions and particularly ventilation that have critical role on their indoor dispersion. This study assesses the impact of outdoor air on indoor air quality in a child care center. Computational fluid dynamics was utilized to analyze the dispersion of particulate matter, with a specific focus on window screens featuring 6 distinct pore sizes ranging from 0.8 mm to 2 mm and 2 different thicknesses of 0.5 mm and 0.1 mm. Results indicate that the presence of a window screen offers significant advantages in controlling particle infiltration compared to scenarios without a screen, as larger particles tend to pass directly through the window within the breathing zone. The scenario without window screens minimizes pressure drop but lacks enhanced particle capture capabilities. However, for effective particle reduction, the window screen with a pore size of 0.8 mm (R0.8T2) and a thickness of 0.5 mm proves to be the most beneficial, achieving the particle filtering efficiency of approximately 54.16%, while the larger window screen with a pore size of 2 mm and a thickness of 1 mm exhibits the lowest efficiency at about 23.85%. Nonetheless, screens with very small sizes are associated with a high-pressure drop, impacting energy efficiency, and overall window performance. Larger pores with smaller thicknesses (0.5 mm) reduced particle count by approximately 45.97%. Therefore, the significance of window screen thickness beyond pore size for particle reduction efficiency is highlighted, emphasizing screens' role in indoor air quality and health protection.

10.
J Environ Health Sci Eng ; 22(1): 295-303, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38887758

RESUMO

Cooking is a significant source of polycyclic aromatic hydrocarbon (PAHs) emissions in indoor environments. A one-month biomonitoring study was carried out in previously selected rural Hungarian kitchens to evaluate cooking-related PAHs concentrations in 4 common kitchen vegetables such as basil, parsley, rocket and chives. The study had two mainobjectives: firstly, to follow PAHs accumulation pattern and to find out if this pattern can be associated with different cooking habits. Also, the usefulness of culinary herbs for indoor bioaccumulation studies was assessed. The 2-ring naphthalene was the dominant PAH in the majority of the samples, its concentrations were in the range of 25.4 µg/kg and 274 µg/kg, of 3-ring PAHs the prevalency of phenanthrene was observed, with highest concentration of 62 µg/kg. PAHs accumulation pattern in tested plants clearly indicated differences in cooking methods and cooking oils used in the selected households. Use of lard and animal fats in general resulted in the high concentrations of higher molecular weight (5- and 6-ring) PAHs, while olive oil usage could be associated with the emission of 2- and 3-ring PAHs. Culinary herbs, however, accumulated carcinogenic PAHs such as benzo[a]anthracene (highest concentration 11.9 µg/kg), benzo[b]fluoranthene (highest concentration 13.8 µg/kg) and chrysene (highest concentration 20.1 µg/kg) which might question their safe use.

11.
Sensors (Basel) ; 24(11)2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38894424

RESUMO

Radon, a radioactive inert gas that comes from the decay of naturally occurring radioactive species, poses a substantial health risk due to its involvement in lung cancer carcinogenesis. This work proposes a metrological approach for determining radon exhalation rates from diverse building materials. This methodology employs an electrostatic collection chamber for alpha spectrometry of radon isotopic decay products. Experimental evaluations were conducted particularly focusing on volcanic gray tuff from Sant'Agata de' Goti (Campania region, Italy), a material commonly utilized in construction, to assess radon exhalation rates. The study aligns with Legislative Decree 101/2020, a transposition of European Directive 59/2013/Euratom, highlighting the need to identify materials with a high risk of radon exhalation. Moreover, this work supports the goals of the Italian National Radon Action Plan related to the aforementioned decree, aiming to develop methodologies for estimating radon exhalation rates from building materials and improving radioprotection practices.

12.
Plants (Basel) ; 13(12)2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38931065

RESUMO

Combustion processes are the primary source of fine particulate matter in indoor air. Since the 1970s, plants have been extensively studied for their potential to reduce indoor air pollution. Leaves can retain particles on their surfaces, influenced by factors such as wax content and the presence of hairs. This study introduces an innovative experimental approach using metal oxide particles in an office-like environment to evaluate the depolluting effect of plant walls. Two plant walls were installed in a controlled room, housing three plant species: Aglaonema commutatum 'Silver Bay', Dracaena fragrans, and Epipremnum aureum. Metal oxide particles were introduced via a compressed air blower positioned between the two walls. The concentration of these particles was monitored using PM2.5 sensors, and the deposition of iron (Fe) on the leaves was quantified through Inductively Coupled Plasma Mass Spectrometry (ICP-MS). This novel methodology effectively demonstrated the utility of both real-time sensors and ICP-MS in quantifying airborne particle concentrations and leaf deposition, respectively. The results revealed that Dracaena fragrans had a 44% higher Fe particle retention rate compared to the control (wallpaper). However, further validation through methodological replication is necessary to confirm the reproducibility of these findings.

13.
Chemosphere ; 362: 142575, 2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38852629

RESUMO

In response to the global impact of the COVID-19 pandemic, international and national authorities, including those in Catalonia (Spain), recognized the crucial need to ensure proper ventilation in classrooms, emphasizing the importance of safe and healthy indoor environments for face-to-face learning. The present work, conducted within the COVID-19 Sentinel Schools Network of Catalonia (CSSNC) framework, aimed to monitor carbon dioxide (CO2) and nitrogen dioxide (NO2) concentrations in 23 schools, ensuring a comprehensive sample regarding educational levels, daily scholar schedules, and classroom typologies distributed across the four provinces of Catalonia. The research spanned three study periods: March and April 2021, October 2021 to January 2022, and March to June 2022. Briefly, 28%, 25%, and 37% of classrooms surpassed the 700 parts per million (ppm) CO2 limit in each study period, respectively. Generally, CO2 averages were lower in preschool classrooms (mean ± SD = 486 ± 106 ppm), while high school classrooms displayed the highest CO2 concentrations (mean ± SD = 710 ± 253 ppm). Moreover, classrooms in towns (<30000 inhabitants) exhibited higher CO2 levels as compared to classrooms from schools located in cities. As for NO2, the highest averages were obtained in urban areas, particularly in the Barcelona metropolitan area (e.g. mean indoor levels of 24.56 µg m-3 as compared to 11.05 µg m-3 in towns). In addition, the Indoor/Outdoor ratio (I/O ratio) in towns was the lowest (0.60). These results, together with the higher concentration of CO2 indoors, could indicate poorer ventilation in town schools. The results of this study are anticipated to contribute to implementing evidence-based measures to improve indoor air quality (IAQ) in educational settings.

14.
Artigo em Inglês | MEDLINE | ID: mdl-38909155

RESUMO

BACKGROUND: Low socioeconomic status (SES) residents living in social housing, which is subsidized by government or government-funded agencies, may have higher exposures to pesticides used in indoor residences since pesticides are applied due to structural deficiencies, poor maintenance, etc. OBJECTIVE: To estimate exposure of residents in low-SES social housing built in the 1970s to legacy and current-use pesticides and to investigate factors related to exposures. METHODS: Twenty-eight particle-phase pesticides were measured in the indoor air of 46 units in seven low-income social housing, multi-unit residential buildings (MURBs) in Toronto, Canada using portable air cleaners deployed for 1 week in 2017. Pesticides analyzed were legacy and current use in the classes: organochlorines, organophosphates, pyrethroids, and strobilurins. RESULTS: At least one pesticide was detected in 89% of the units with detection frequencies (DF) for individual pesticides of up to 50%, including legacy organochlorines and current-use pesticides. Current-use pyrethroids had the highest DF and concentrations, with the highest particle-phase concentration for pyrethrin I at 32,000 pg/m3. Heptachlor, restricted for use in Canada in 1985, had the highest estimated maximum total air (particle plus gas phase) concentration of 443,000 pg/m3. Heptachlor, lindane, endosulfan I, chlorothalonil, allethrin, and permethrin (except in one study) had higher concentrations than those measured in low-income residences reported elsewhere. In addition to the intentional use of pesticides to control pests and their use in building materials and paints, tobacco smoking was significantly correlated with the concentrations of five pesticides used on tobacco crops. The distribution of pesticides with high DF in individual buildings suggested that pest eradication programs by the building management and/or pesticide use by residents were the major sources of measured pesticides. IMPACT: Low-income social housing fills a much-needed demand, but the residences are prone to pest infestation and hence pesticide use. We found exposure to at least 1 of 28 particle-phase pesticides in 89% of all 46 units tested, with the highest DF and concentrations for current-use pyrethroids and long-banned organochlorines (e.g., DDT, heptachlor) due to very high persistence indoors. Also measured were several pesticides not registered for use indoors, e.g., strobilurins used to treat building materials and pesticides used on tobacco crops. These results, which are the first Canadian data for most pesticides indoors, show widespread exposure to numerous pesticides.

15.
Int J Environ Health Res ; : 1-14, 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38860645

RESUMO

A cross-sectional study was conducted among 126 preschool children aged 4-6 years in traffic, industrial, and suburban areas of Penang, Malaysia, to determine their exposure to indoor air pollutants and their associations with respiratory symptoms. A standardised and validated questionnaire was used to collect data on respiratory health symptoms among respondents. An indoor air quality assessment was conducted in selected preschools that included temperature, relative humidity, air velocity, volatile organic compounds (VOCs), and particulate matter (PM2.5, and PM10). There were significant differences in median concentrations of PM2.5, PM10 and relative humidity among study groups. Statistical analysis showed significant associations between air pollutants in preschool with respiratory symptoms. Factors that influenced the increased likelihood of cough and phlegm were linked to the increase in PM2.5 exposure. This study suggests regular classroom cleaning and routine maintenance of air conditioners to be done inside the preschools.

16.
Environ Health Insights ; 18: 11786302241258587, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38863688

RESUMO

Particulate matter (PM) exposure is associated with adverse health outcomes, including respiratory illness. A large fraction of exposure to airborne contaminants occurs in the home. This study, conducted over 5 months in a community with high asthma rates (Chelsea, MA, USA), investigated the use of portable air cleaners (PACs) to reduce indoor PM. Seven asthma-affected households participated, receiving a PAC (Austin Air Health Mate HEPA filter), a QuantAQ sensor to measure PM1, PM2.5, PM10 (µg/m3), and a HOBO plug-load data logger to track PAC usage. Results describe hourly and daily PM concentrations and PAC usage for each household. Hourly average PM concentrations decreased when PACs were turned on (vs. when they were turned off) across households during the study period: PM1 decreased by 0.46 µg/m3, PM2.5 decreased by 0.69 µg/m3, and PM10 decreased by 3.22 µg/m3. PAC usage varied for each household, including constant usage in one household and only usage at certain times of day in others. Higher filtration settings led to lower PM, with significant reductions in some, but not all, homes. Our findings highlight some difficulties in implementing household PAC interventions, yet also provide evidence to support household-level interventions to reduce PM and other indoor sources of air pollution. We also highlight academic-community partnerships as contributing to evidence-based solutions.

17.
J Environ Manage ; 363: 121414, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38852418

RESUMO

This study explores the effectiveness of a botanical bioscrubber system using Golden Pothos (Epipremnum aureum) in hydroponic setups to mitigate common indoor atmospheric pollutants. Over a 100-day operation, levels of SO2, NO2, O3, TVOC, CO, CO2, PM10, and PM2.5 were monitored, with a significant reduction in carbon-based compounds and particulate matter-. Notably, CO2 and PM2.5 removal efficiencies were significantly correlated with the foliar area, suggesting that the interaction between pollutants and plant leaves plays a crucial role in the phytoremediation process. In contrast, CO, PM10, and TVOC exhibited varied removal efficiencies, hinting the involvement of mechanisms beyond leaf interaction, such as adsorption in irrigation water or root system capture. The absence of significant correlations for PM10 emphasized the need for further investigation into alternative removal processes, potentially mediated by the root system. Overall, our findings suggest that botanical bioscrubbers, particularly those utilizing Golden Pothos, hold promise for indoor air purification through plant-based systems.


Assuntos
Poluentes Atmosféricos , Poluição do Ar em Ambientes Fechados , Material Particulado , Poluentes Atmosféricos/análise , Biodegradação Ambiental , Folhas de Planta
18.
ACS Sens ; 9(6): 2999-3008, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38860548

RESUMO

Health and safety considerations of indoor occupants in enclosed spaces are crucial for building management which involves the strict control and monitoring of carbon dioxide levels to maintain acceptable air quality standards. For this study, we developed a wireless, noninvasive, and portable platform for the continuous monitoring of carbon dioxide concentration in enclosed environments, i.e., academic rooms. The system aimed to monitor and detect carbon dioxide using novel low-cost metal oxide-based chemoresistive sensors, achieving sensing performance comparable to those of commercially available detectors based on optical working principle, e.g., nondispersive infrared sensors. In particular, a predictive study of carbon dioxide levels was performed by exploiting random forest and curve fitting algorithms on chemoresistive sensor data collected in an academic room, then comparing the results with lab-based measurements. The performance of the models was evaluated with real environment conditions during 7 weeks. The field measurements were conducted to validate and support the development of the system for real-time monitoring and alerting in the presence of relevant concentrations (above 1,000 ppm). Therefore, the study highlighted that the curve fitting model obtained was able to recognize with an F1-score of 0.77 the presence of poor air quality, defined as concentration above 1,000 ppm of carbon dioxide as reported by the Occupational Safety and Health Administration.


Assuntos
Poluição do Ar em Ambientes Fechados , Dióxido de Carbono , Monitoramento Ambiental , Dióxido de Carbono/análise , Poluição do Ar em Ambientes Fechados/análise , Monitoramento Ambiental/métodos , Monitoramento Ambiental/instrumentação , Algoritmos
19.
Environ Sci Technol ; 58(27): 12051-12061, 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38922431

RESUMO

Germicidal ultraviolet light (GUV) systems are designed to control airborne pathogen transmission in buildings. However, it is important to acknowledge that certain conditions and system configurations may lead GUV systems to produce air contaminants including oxidants and secondary organic aerosols (SOA). In this study, we modeled the formation and dispersion of oxidants and secondary contaminants generated by the operation of GUV systems employing ultraviolet C 254 and 222 nm. Using a three-dimensional computational fluid dynamics model, we examined the breathing zone concentrations of chemical species in an occupied classroom. Our findings indicate that operating GUV 222 leads to an approximate increase of 10 ppb in O3 concentration and 5.2 µg·m-3 in SOA concentration compared to a condition without GUV operation, while GUV 254 increases the SOA concentration by about 1.2 µg·m-3, with a minimal impact on the O3 concentration. Furthermore, increasing the UV fluence rate of GUV 222 from 1 to 5 µW·cm-2 results in up to 80% increase in the oxidants and SOA concentrations. For GUV 254, elevating the UV fluence rate from 30 to 50 µW·cm-2 or doubling the radiating volume results in up to 50% increase in the SOA concentration. Note that indoor airflow patterns, particularly buoyancy-driven airflow (or displacement ventilation), lead to 15-45% lower SOA concentrations in the breathing zone compared to well-mixed airflow. The results also reveal that when the ventilation rate is below 2 h-1, operating GUV 254 has a smaller impact on human exposure to secondary contaminants than GUV 222. However, GUV 254 may generate more contaminants than GUV 222 when operating at high indoor O3 levels (>15 ppb). These results suggest that the design of GUV systems should consider indoor O3 levels and room ventilation conditions.


Assuntos
Raios Ultravioleta , Poluição do Ar em Ambientes Fechados , Aerossóis , Poluentes Atmosféricos , Ozônio , Humanos
20.
Environ Sci Pollut Res Int ; 31(32): 44463-44488, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38943001

RESUMO

Indoor air quality (IAQ) in the built environment is significantly influenced by particulate matter, volatile organic compounds, and air temperature. Recently, the Internet of Things (IoT) has been integrated to improve IAQ and safeguard human health, comfort, and productivity. This review seeks to highlight the potential of IoT integration for monitoring IAQ. Additionally, the paper details progress by researchers in developing IoT/mobile applications for IAQ monitoring, and their transformative impact in smart building, healthcare, predictive maintenance, and real-time data analysis systems. It also outlines the persistent challenges (e.g., data privacy, security, and user acceptability), hampering effective IoT implementation for IAQ monitoring. Lastly, the global developments and research landscape on IoT for IAQ monitoring were examined through bibliometric analysis (BA) of 106 publications indexed in Web of Science from 2015 to 2022. BA revealed the most significant contributing countries are India and Portugal, while the top productive institutions and researchers are Instituto Politecnico da Guarda (10.37% of TP) and Marques Goncalo (15.09% of TP), respectively. Keyword analysis revealed four major research themes: IoT, pollution, monitoring, and health. Overall, this paper provides significant insights for identifying prospective collaborators, benchmark publications, strategic funding, and institutions for future IoT-IAQ researchers.


Assuntos
Poluição do Ar em Ambientes Fechados , Bibliometria , Monitoramento Ambiental , Poluentes Atmosféricos/análise , Monitoramento Ambiental/métodos , Internet das Coisas , Material Particulado/análise , Compostos Orgânicos Voláteis/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...