Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20.477
Filtrar
1.
J Environ Sci (China) ; 147: 512-522, 2025 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-39003067

RESUMO

To better understand the migration behavior of plastic fragments in the environment, development of rapid non-destructive methods for in-situ identification and characterization of plastic fragments is necessary. However, most of the studies had focused only on colored plastic fragments, ignoring colorless plastic fragments and the effects of different environmental media (backgrounds), thus underestimating their abundance. To address this issue, the present study used near-infrared spectroscopy to compare the identification of colored and colorless plastic fragments based on partial least squares-discriminant analysis (PLS-DA), extreme gradient boost, support vector machine and random forest classifier. The effects of polymer color, type, thickness, and background on the plastic fragments classification were evaluated. PLS-DA presented the best and most stable outcome, with higher robustness and lower misclassification rate. All models frequently misinterpreted colorless plastic fragments and its background when the fragment thickness was less than 0.1mm. A two-stage modeling method, which first distinguishes the plastic types and then identifies colorless plastic fragments that had been misclassified as background, was proposed. The method presented an accuracy higher than 99% in different backgrounds. In summary, this study developed a novel method for rapid and synchronous identification of colored and colorless plastic fragments under complex environmental backgrounds.


Assuntos
Monitoramento Ambiental , Aprendizado de Máquina , Plásticos , Espectroscopia de Luz Próxima ao Infravermelho , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Monitoramento Ambiental/métodos , Plásticos/análise , Análise dos Mínimos Quadrados , Análise Discriminante , Cor
2.
J Biomed Opt ; 30(Suppl 1): S13702, 2025 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-39034960

RESUMO

Significance: Near-infrared autofluorescence (NIRAF) utilizes the natural autofluorescence of parathyroid glands (PGs) to improve their identification during thyroid surgeries, reducing the risk of inadvertent removal and subsequent complications such as hypoparathyroidism. This study evaluates NIRAF's effectiveness in real-world surgical settings, highlighting its potential to enhance surgical outcomes and patient safety. Aim: We evaluate the effectiveness of NIRAF in detecting PGs during thyroidectomy and central neck dissection and investigate autofluorescence characteristics in both fresh and paraffin-embedded tissues. Approach: We included 101 patients diagnosed with papillary thyroid cancer who underwent surgeries in 2022 and 2023. We assessed NIRAF's ability to locate PGs, confirmed via parathyroid hormone assays, and involved both junior and senior surgeons. We measured the accuracy, speed, and agreement levels of each method and analyzed autofluorescence persistence and variation over 10 years, alongside the expression of calcium-sensing receptor (CaSR) and vitamin D. Results: NIRAF demonstrated a sensitivity of 89.5% and a negative predictive value of 89.1%. However, its specificity and positive predictive value (PPV) were 61.2% and 62.3%, respectively, which are considered lower. The kappa statistic indicated moderate to substantial agreement (kappa = 0.478; P < 0.001 ). Senior surgeons achieved high specificity (86.2%) and PPV (85.3%), with substantial agreement (kappa = 0.847; P < 0.001 ). In contrast, junior surgeons displayed the lowest kappa statistic among the groups, indicating minimal agreement (kappa = 0.381; P < 0.001 ). Common errors in NIRAF included interference from brown fat and eschar. In addition, paraffin-embedded samples retained stable autofluorescence over 10 years, showing no significant correlation with CaSR and vitamin D levels. Conclusions: NIRAF is useful for PG identification in thyroid and neck surgeries, enhancing efficiency and reducing inadvertent PG removals. The stability of autofluorescence in paraffin samples suggests its long-term viability, with false positives providing insights for further improvements in NIRAF technology.


Assuntos
Imagem Óptica , Glândulas Paratireoides , Espectroscopia de Luz Próxima ao Infravermelho , Tireoidectomia , Humanos , Glândulas Paratireoides/cirurgia , Glândulas Paratireoides/metabolismo , Masculino , Feminino , Pessoa de Meia-Idade , Imagem Óptica/métodos , Adulto , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Inclusão em Parafina/métodos , Idoso , Câncer Papilífero da Tireoide/cirurgia , Câncer Papilífero da Tireoide/patologia , Câncer Papilífero da Tireoide/metabolismo , Receptores de Detecção de Cálcio/metabolismo , Receptores de Detecção de Cálcio/análise
3.
Int J Mol Sci ; 25(13)2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-39000448

RESUMO

Bioluminescence imaging (BLI) is an indispensable technique for visualizing the dynamics of diverse biological processes in mammalian animal models, including cancer, viral infections, and immune responses. However, a critical scientific challenge remains: non-invasively visualizing homeostatic and disease mechanisms in freely moving animals to understand the molecular basis of exercises, social behavior, and other phenomena. Classical BLI relies on prolonged camera exposure to accumulate the limited number of photons that traveled from deep tissues in anesthetized or constrained animals. Recent advancements in synthetic bioluminescence reactions, utilizing artificial luciferin-luciferase pairs, have considerably increased the number of detectable photons from deep tissues, facilitating high-speed BLI to capture moving objects. In this review, I provide an overview of emerging synthetic bioluminescence reactions that enable the non-invasive imaging of freely moving animals. This approach holds the potential to uncover unique physiological processes that are inaccessible with current methodologies.


Assuntos
Medições Luminescentes , Animais , Medições Luminescentes/métodos , Luciferases/metabolismo , Luciferases/genética , Humanos
4.
Talanta ; 278: 126495, 2024 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-38955105

RESUMO

Accurate and sensitive determination of human immunoglobulin G (HIgG) level is critical for diagnosis and treatment of various diseases, including rheumatoid arthritis, humoral immunodeficiencies, and infectious disease. In this study, versatile tri-signal probes were developed by preparing CdS@SiO2 nanorods that integrate photoluminescence (PL), multi-phonon resonant Raman scattering (MRRS) and infrared absorption (IRA) properties. Through the coating of multiple CdS nanoparticles as cores within SiO2 shells, the PL and MRRS properties of CdS were improved, resulting in a significantly lowered limit of detection (LOD), with the lowest LOD of 12.37 ag mL-1. Integration with the distinctive IRA property of SiO2 shells widened the detection range towards higher concentrations, establishing a final linear range of 50 ag mL-1 to 10 µg mL-1. The remarkable consistency among the three signals highlighted the robust internal verification capability for accurate detection. This approach enhances flexibility in selecting detection methodologies to suit diverse scenarios, facilitating HIgG detection. The tri-signal nanoprobes also exhibited excellent detection selectivity, specificity and repeatability. This study presents a fresh idea for developing high-performance detection strategies.

5.
Adv Sci (Weinh) ; : e2405677, 2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-38994890

RESUMO

Photoacoustic (PA) emitters are emerging ultrasound sources offering high spatial resolution and ease of miniaturization. Thus far, PA emitters rely on electronic transitions of absorbers embedded in an expansion matrix such as polydimethylsiloxane (PDMS). Here, it is shown that mid-infrared vibrational excitation of C─H bonds in a transparent PDMS film can lead to efficient mid-infrared photoacoustic conversion (MIPA). MIPA shows 37.5 times more efficient than the commonly used PA emitters based on carbon nanotubes embedded in PDMS. Successful neural stimulation through MIPA both in a wide field with a size up to a 100 µm radius and in single-cell precision is achieved. Owing to the low heat conductivity of PDMS, less than a 0.5 °C temperature increase is found on the surface of a PDMS film during successful neural stimulation, suggesting a non-thermal mechanism. MIPA emitters allow repetitive wide-field neural stimulation, opening up opportunities for high-throughput screening of mechano-sensitive ion channels and regulators.

6.
Small ; : e2401194, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38984765

RESUMO

High-sensitive uncooled mid-wave infrared (MWIR) photodetection with fast speed is highly desired for biomedical imaging, optical communication, and night vision technology. Low-dimensional materials with low dark current and broadband photoresponse hold great promise for use in MWIR detection. Here, this study reports a high-performance MWIR photodetector based on a titanium trisulfide (TiS3) nanoribbon. This device demonstrates an ultra-broadband photoresponse ranging from the visible spectrum to the MWIR spectrum (405-4275 nm). In the MWIR spectral range, the photodetector achieves competitive high photoresponsivity (R) of 21.1 A W-1, and an impressive specific detectivity (D*) of 5.9 × 1010 cmHz1/2 W-1 in ambient air. Remarkably, the photoresponse speed in the MWIR with τr = 1.3 ms and τd = 1.5 ms is realized which is much faster than the thermal time constant of 15 ms. These findings pave the way for highly sensitive, room-temperature MWIR photodetectors with exceptionally fast response speed.

7.
Angew Chem Int Ed Engl ; : e202407833, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38984901

RESUMO

Near-infrared light-emitting diodes (NIR LEDs) based on perovskite quantum dots (QDs) have produced external quantum efficiency (EQE) of ~15%. However, these high-performance NIR-QLEDs suffer from immediate carrier quenching because of the accumulation of migratable ions at the surface of the QDs. These uncoordinated ions and carriers - if not bound to the nanocrystal surface - serve as centers for exciton quenching and device degradation. In this work, we overcome this issue and fabricate high-performance NIR QLEDs by devising a ligand anchoring strategy, which entails dissolving the strong-binding ligand (Guanidine Hydroiodide, GAI) in the mediate-polar solvent. By employing the dye-sensitized device structure (phosphorescent indicator), we demonstrate the elimination of the interface defects. The treated QDs films exhibit an exciton binding energy of 117 meV: this represents a 1.5-fold increase compared to that of the control (74 meV). We report, as a result, the NIR QLEDs with an EQE of 21% which is a record among NIR perovskite QLEDs. These QLEDs also exhibit a 7-fold higher operational stability than that of the best previously reported NIR QLEDs. Furthermore, we demonstrate that the QDs are compatible with large-area QLEDs: we showcase 900 mm2 QLEDs with EQE approaching 20%.

8.
Gland Surg ; 13(6): 1031-1044, 2024 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-39015719

RESUMO

Background: Fluorescence-guided surgery (FGS) is a cutting-edge technology that uses near-infrared (NIR) fluorescence imaging to guide surgeons in surgery. Indocyanine green (ICG) is a fluorescent dye, which can be used for in vivo imaging of tumor cells. We aimed to explore the use of ICG fluorescence-guided technology as a rapid intraoperative margin assessment method for breast cancer surgery. In addition, we also compared the dose selection of ICG. Methods: This was a non-randomized prospective cohort study. Data were collected between August 2021 and October 2022 in the Division of Breast Surgery, Department of General Surgery, Nanjing Drum Tower Hospital, the Affiliated Hospital of Medical School, Nanjing University. Upon specimen removal, tumor margins were immediately analyzed by ICG fluorescence detection and then sent to the pathology department for intraoperative frozen section analysis and subsequent routine pathological examination. Abnormal margin rates were calculated and compared using intraoperative frozen section analysis and under the guidance of ICG fluorescence. Results: The study included 69 cases of breast cancer patients who underwent tumor resection assisted by ICG fluorescence-guided technology, including 18 patients with a 0.5 mg/kg dose and 51 patients with a 1.0 mg/kg dose. According to the study findings, the ICG test achieved a sensitivity of 81.82% and a specificity of 75.82%. At a dose of 0.5 mg/kg, the sensitivity was 66.67% whereas the specificity was 93.33%. At the dose of 1 mg/kg, the sensitivity was 87.5%, and the specificity was 74.42%. Similarly, for intraoperative frozen section analysis, the sensitivity was 81.82%, but the specificity was enhanced to 94.83%. Positive surgical cut margin was not identified in 2/69 by ICG fluorescence and frozen section analysis respectively. Conclusions: The sensitivity of ICG fluorescence detection is comparable to that of frozen section analysis, but the specificity is poor. The sensitivity increased and the specificity decreased at 1 mg/kg compared to the 0.5 mg/kg dose. ICG fluorescence can be used as a supplementary tool for frozen section analysis. These findings support further development and clinical performance assessment of ICG fluorescence.

10.
Chemosphere ; : 142871, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39019177

RESUMO

Owing to extensive plastic consumption, wastewater from households, business establishments, and industrial activities has been recognised as a significant contributor to microplastics (MPs) in aquatic environments. This case study represents the first investigation of MPs in the Nakdong River, Republic of Korea, that traverses through the largest industrial complex midstream and densely populated cities of Daegu and Busan downstream before flowing into the sea. Monitoring of MP abundance in effluents discharged from three municipal, two industrial, and one livestock wastewater treatment plant (WWTP) into the Nakdong River was conducted over four seasons from August 2022 to April 2023. Identification and quantification of MPs were performed using micro-Fourier transform infrared spectrometry. Seasonal variation in MPs in the Nakdong River was found to be strongly influenced by the nearest upstream WWTPs and rivers, exhibiting a linear relationship that decreased gradually with increasing distance from the WWTPs. The average concentrations of MPs in the six effluent sources ranged from 101±13 to 490±240 particles/L during the yearly monitoring period, while MP concentrations in the river ranged between 90±41 and 120±43 particles/L. Industrial effluents contained higher amounts of discharged MPs (314±78 particles/L) than did municipal sources (201±61 particles/L). Notably, two municipal WWTPs, located in the highly densely populated city, discharged the highest total MP amounts per day and released the greatest volumes of effluents. This study provides valuable insights into the monitoring and impact of effluents on MPs in rivers, which could inform MP treatment and management strategies for in river and marine environments.

11.
Luminescence ; 39(7): e4836, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39023133

RESUMO

The near-infrared (NIR) down-conversion process for broadband sensitization has been studied in Eu2+-Nd3+ co-doped BaAl2O4. This material has a broad absorption band of 200-480 nm and can convert photons in the visible region into NIR photons. The NIR emission at 1064 nm, attributed to the Nd3+:4F3/2 → 4I11/2 transition, matches the bandgap of Si, allowing Si solar cells to utilize the solar spectrum better. The energy transfer (ET) process between Eu2+ and Nd3+ was demonstrated using photoluminescence spectra and luminescence decay curves, and Eu2+ may transfer energy to Nd3+ through the cooperative energy transfer (CET) to achieve the down-conversion process. The energy transfer efficiency (ETE) and theoretical quantum efficiency (QE) were 68.61% and 156.34%, respectively, when 4 mol% Nd3+ was introduced. The results indicate that BaAl2O4:Eu2+-Nd3+ can serve as a potential modulator of the solar spectrum and is expected to be applied to Si solar cells.


Assuntos
Európio , Raios Infravermelhos , Neodímio , Silício , Energia Solar , Európio/química , Silício/química , Neodímio/química , Luminescência , Transferência de Energia , Bário/química , Medições Luminescentes
12.
Adv Sci (Weinh) ; : e2403398, 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39023182

RESUMO

This study describes the formation of single-chain polymer dots (Pdots) via ultrasonic emulsification of nonionic donor-acceptor-donor type (D-A-D) alkoxy thiophene-benzobisthiadiazole-based conjugated polymers (Poly BT) with amphiphilic cetyltrimethylammonium bromide (CTAB). The methodology yields Pdots with a high cationic surface charge (+56.5 mV ± 9.5) and average hydrodynamic radius of 12 nm. Optical characterization reveals that these Pdots emit near-infrared (NIR) light at a maximum wavelength of 860 nm owing to their conjugated polymer backbone consisting of D-A-D monomers. Both colloidal and optical properties of these Pdots make them promising fluorescence emissive probes for bioimaging applications. The significant advantage of positively charged Pdots is demonstrated in diffusion-limited mediums such as tissues, utilizing human epithelial breast adenocarcinoma, ATCC HTB-22 (MCF-7), human bone marrow neuroblastoma, ATCC CRL-2266 (SH-SY5Y), and rat adrenal gland pheochromocytoma, CRL-1721 (PC-12) tumor spheroid models. Fluorescence microscopy analysis of tumor spheroids from MCF-7, SH-SY5Y, and PC-12 cell lines reveals the intensity profile of Pdots, confirming extensive penetration into the central regions of the models. Moreover, a comparison with mitochondria staining dye reveals an overlap between the regions stained by Pdots and the dye in all three tumor spheroid models. These results suggest that single-chain D-A-D type Pdots, cationized via CTAB, exhibit long-range mean free path of penetration (≈1 µm) in dense mediums and tumors.

13.
Sci Rep ; 14(1): 16314, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39009692

RESUMO

The benefits of physical exercise on human health make it desirable to identify new approaches that would mimic or potentiate the effects of exercise to treat metabolic diseases. However, whether far-infrared (FIR) hyperthermia therapy could be used as exercise mimetic to realize wide-ranging metabolic regulation, and its underling mechanisms remain unclear. Here, a specific far-infrared (FIR) rays generated from graphene-based hyperthermia devices might promote exercise capacity and metabolisms. The material characterization showed that the graphene synthesized by chemical vapour deposition (CVD) was different from carbon fiber, with single-layer structure and high electrothermal transform efficiency. The emission spectra generated by graphene-FIR device would maximize matching those adsorbed by tissues. Graphene-FIR enhanced both core and epidermal temperatures, leading to increased blood flow in the femoral muscle and the abdominal region. The combination of microbiomic and metabolomic analysis revealed that graphene-FIR modulates the metabolism of the gut-muscle axis. This modulation was characterized by an increased abundance of short-chain fatty acids (SCFA)-producing bacteria and AMP, while lactic acid levels decreased. Furthermore, the principal routes involved in glucose metabolism, such as glycolysis and gluconeogenesis, were found to be altered. Graphene-FIR managed to stimulate AMPK activity by activating GPR43, thus enhancing muscle glucose uptake. Furthermore, a microbiota disorder model also demonstrated that the graphene-FIR effectively restore the exercise endurance with enhanced p-AMPK and GLUT4. Our results provided convincing evidence that graphene-based FIR therapy promoted exercise capacity and glucose metabolism via AMPK in gut-muscle axis. These novel findings regarding the therapeutic effects of graphene-FIR suggested its potential utility as a mimetic agent in clinical management of metabolic disorders.


Assuntos
Glucose , Grafite , Homeostase , Raios Infravermelhos , Condicionamento Físico Animal , Animais , Camundongos , Glucose/metabolismo , Grafite/farmacologia , Grafite/química , Proteínas Quinases Ativadas por AMP/metabolismo , Masculino , Microbioma Gastrointestinal , Músculo Esquelético/metabolismo , Camundongos Endogâmicos C57BL , Hipertermia Induzida/métodos , Tolerância ao Exercício , Microbiota
14.
ACS Appl Mater Interfaces ; 16(28): 35925-35935, 2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-38950334

RESUMO

The development of efficient theranostic nanoagents for the precise diagnosis and targeted therapy of glioblastoma (GBM) remains a big challenge. Herein, we designed and developed porphyrin-based organic nanoparticles (PNP NPs) with strong emission in the near-infrared IIa window (NIR-IIa) for orthotopic GBM theranostics. PNP NPs possess favorable photoacoustic and photothermal properties, high photostability, and low toxicity. After modification with the RGD peptide, the obtained PNPD NPs exhibited enhanced blood-brain barrier (BBB) penetration capability and GBM targeting ability. NIR-IIa imaging was employed to monitor the in vivo biodistribution and accumulation of the nanoparticles, revealing a significant enhancement in penetration depth and signal-to-noise ratio. Both in vitro and in vivo results demonstrated that PNPD NPs effectively inhibited the proliferation of tumor cells and induced negligible side effects in normal brain tissues. In general, the work presented a kind of brain-targeted porphyrin-based NPs with NIR-IIa fluorescence for orthotopic glioblastoma theranostics, showing promising prospects for clinical translation.


Assuntos
Glioblastoma , Nanopartículas , Porfirinas , Nanomedicina Teranóstica , Glioblastoma/diagnóstico por imagem , Glioblastoma/tratamento farmacológico , Glioblastoma/patologia , Glioblastoma/metabolismo , Animais , Nanopartículas/química , Humanos , Porfirinas/química , Porfirinas/farmacologia , Camundongos , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/tratamento farmacológico , Neoplasias Encefálicas/patologia , Linhagem Celular Tumoral , Raios Infravermelhos , Distribuição Tecidual , Barreira Hematoencefálica/metabolismo , Camundongos Nus , Antineoplásicos/química , Antineoplásicos/farmacologia , Proliferação de Células/efeitos dos fármacos , Camundongos Endogâmicos BALB C , Fluorescência
15.
ACS Appl Mater Interfaces ; 16(28): 36527-36538, 2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-38961586

RESUMO

The development of broadband photosensors has become crucial in various fields. Indium-gallium-zinc oxide (IGZO, In:Ga:Zn = 1:1:1) phototransistors with PbS quantum dots (QDs) have shown promising features for such sensors, such as reasonable mobility, low leakage current, good photosensitivity, and low-cost fabrication. However, the instability of PbS QD/IGZO phototransistors under an air atmosphere and prolonged storage remain serious concerns. In this article, two concepts to improve the reliability of PbS QD/IGZO phototransistors were implemented. P-type doping in the PbS QD layer through oxidation allows increasing the built-in potential between IGZO and PbS QDs, leading to enhancement in photoinduced electron-hole pair creation. Second, agglomeration and fusion of a PbS QDs layer were controlled via thermal annealing, which facilitated the transport of photocreated carriers. The p-type doping and interconnection of a PbS QD layer can be achieved by deposition and subsequent thermal annealing of gallium oxide (Ga2O3) on PbS QD/IGZO stacks. The resulting Ga2O3/PbS QD/IGZO phototransistors exhibited high-performance switching characteristics under dark conditions. Notably, they showed a remarkable photoresponsivity of 196.69 ± 4.05 A/W and a detectivity of (5.47 ± 1.4) × 1012 Jones even at a long-wavelength illumination of 1550 nm. While the unpassivated PbS/IGZO phototransistor suffered serious degradation in optical performance after 2 weeks of storage, the Ga2O3/PbS QD/IGZO phototransistor demonstrated enhanced stability, maintaining high performance for over 5 weeks. These findings suggest that Ga2O3/PbS QD/IGZO phototransistors offer a feasible approach for the fabrication of large-scale active matrix broadband photosensor arrays, potentially revolutionizing optical sensing in various cutting-edge applications.

16.
Adv Sci (Weinh) ; : e2400229, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38973266

RESUMO

Inflammatory responses play a central role in coordinating biomaterial-mediated tissue regeneration. However, precise modulation of dynamic variations in microenvironmental inflammation post-implantation remains challenging. In this study, the traditional ß-tricalcium phosphate-based scaffold is remodeled via ultrathin MXene-Ti3C2 decoration and Zn2+/Sr2+ ion-substitution, endowing the scaffold with excellent reactive oxygen species-scavenging ability, near-infrared responsivity, and enhanced mechanical properties. The induction of mild hyperthermia around the implant via periodic near-infrared irradiation facilitates spatiotemporal regulation of inflammatory cytokines secreted by a spectrum of macrophage phenotypes. The process initially amplifies the pro-inflammatory response, then accelerates M1-to-M2 macrophage polarization transition, yielding a satisfactory pattern of osteo-immunomodulation during the natural bone healing process. Later, sustained release of Zn2+/Sr2+ ions with gradual degradation of the 3D scaffold maintains the favorable reparative M2-dominated immunological microenvironment that supports new bone mineralization. Precise temporal immunoregulation of the bone healing process by the intelligent 3D scaffold enhances bone regeneration in a rat cranial defect model. This strategy paves the way for the application of ß-tricalcium phosphate-based materials to guide the dynamic inflammatory and bone tissue responses toward a favorable outcome, making clinical treatment more predictable and durable. The findings also demonstrate that near-infrared irradiation-derived mild hyperthermia is a promising method of immunomodulation.

17.
Angew Chem Int Ed Engl ; : e202408284, 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38979690

RESUMO

We study by femtosecond infrared spectroscopy the ultrafast and persistent photoinduced phase transition of the Rb0.94Mn0.94Co0.06[Fe(CN)6]0.98∙0.2H2O material, induced at room temperature by a single laser shot. This system exhibits a charge-transfer based phase transition with a 75 K wide thermal hysteresis, centred at room temperature, from the low temperature Mn3+-N-C-Fe2+ tetragonal phase to the high temperature Mn2+-N-C-Fe3+ cubic phase. At room temperature, the photoinduced phase transition is persistent. However, the out-of-equilibrium dynamics leading to this phase is multi-scale. Femtosecond infrared spectroscopy, particularly sensitive to local reorganizations through the evolution of the frequency of the N-C vibration modes with the different characteristic electronic states, reveals that at low laser fluence and on short time scale, the photoexcitation of the Mn3+-N-C-Fe2+ phase creates small charge-transfer polarons [Mn2+-N-C-Fe3+]* within ≃ 250 fs. The local trapping of photoinduced intermetallic charge-transfer is characterized by the appearance of a polaronic infrared band, due to the surrounding Mn2+-N-C-Fe2+ species. Above a threshold fluence, when a critical fraction of small CT-polarons is reached, the macroscopic phase transition to the persistent Mn2+-N-C-Fe3+ cubic phase occurs within ≃ 100 ps. This non-linear photo-response results from elastic cooperativity, intrinsic to a switchable lattice and reminiscent of a feedback mechanism.

18.
Heliyon ; 10(12): e33221, 2024 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-39005893

RESUMO

Moxibustion has a long history of use as a traditional Chinese medicine therapy. Infrared radiation is an important and effective factor in moxibustion. Instead of the time-consuming and laborious process of holding moxa sticks in the hand, moxibustion devices are commonly used as moxibustion methods and tools in modern times. With the publication of the international standard of moxibustion devices (ISO18666:2021, Traditional Chinese Medicine - General requirements of moxibustion devices) published, moxibustion devices of various materials are now sold in the pharmacies and online stores. However, the influence of moxibustion devices on the therapeutic effect of moxibustion has not been studied. Therefore, this research was aimed to evaluate the infrared radiation of moxibustion devices, in order to select the moxibustion device that delivered infrared radiation closest to that of moxa stick combustion. The combination of combustion stability and infrared radiation intensity showed that cardboard tubes and silicone were better materials for moxibustion devices. In the mid-far infrared wave band, the moxibustion devices made from cardboard tubes and silica gels can better maintain the thermal effect generated by moxibustion and enable it to be more easily absorbed by the human body. The infrared radiation intensity of the cardboard moxibustion devices increased rapidly and steadily and could be maintained for the longest time. In conclusion, cardboard tubes are the better material for moxibustion devices with respect to infrared radiation.

19.
Neurooncol Adv ; 6(1): vdae082, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39006162

RESUMO

Background: Infrared (IR) spectroscopy allows intraoperative, optical brain tumor diagnosis. Here, we explored it as a translational technology for the identification of aggressive meningioma types according to both, the WHO CNS grading system and the methylation classes (MC). Methods: Frozen sections of 47 meningioma were examined by IR spectroscopic imaging and different classification approaches were compared to discern samples according to WHO grade or MC. Results: IR spectroscopic differences were more pronounced between WHO grade 2 and 3 than between MC intermediate and MC malignant, although similar spectral ranges were affected. Aggressive types of meningioma exhibited reduced bands of carbohydrates (at 1024 cm-1) and nucleic acids (at 1080 cm-1), along with increased bands of phospholipids (at 1240 and 1450 cm-1). While linear discriminant analysis was able to discern spectra of WHO grade 2 and 3 meningiomas (AUC 0.89), it failed for MC (AUC 0.66). However, neural network classifiers were effective for classification according to both WHO grade (AUC 0.91) and MC (AUC 0.83), resulting in the correct classification of 20/23 meningiomas of the test set. Conclusions: IR spectroscopy proved capable of extracting information about the malignancy of meningiomas, not only according to the WHO grade, but also for a diagnostic system based on molecular tumor characteristics. In future clinical use, physicians could assess the goodness of the classification by considering classification probabilities and cross-measurement validation. This might enhance the overall accuracy and clinical utility, reinforcing the potential of IR spectroscopy in advancing precision medicine for meningioma characterization.

20.
Sensors (Basel) ; 24(13)2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-39000826

RESUMO

Advances in neuroimaging technology, like functional near-infrared spectroscopy (fNIRS), support the evaluation of task-dependent brain activity during functional tasks, like balance, in healthy and clinical populations. To date, there have been no studies examining how interventions, like yoga, impact task-dependent brain activity in adults with chronic acquired brain injury (ABI). This pilot study compared eight weeks of group yoga (active) to group exercise (control) on balance and task-dependent neural activity outcomes. Twenty-three participants were randomized to yoga (n = 13) or exercise groups (n = 10). Neuroimaging and balance performance data were collected simultaneously using a force plate and mobile fNIRS device before and after interventions. Linear mixed-effects models were used to evaluate the effect of time, time x group interactions, and simple (i.e., within-group) effects. Regardless of group, all participants had significant balance improvements after the interventions. Additionally, regardless of group, there were significant changes in task-dependent neural activity, as well as distinct changes in neural activity within each group. In summary, using advances in sensor technology, we were able to demonstrate preliminary evidence of intervention-induced changes in balance and neural activity in adults with ABI. These preliminary results may provide an important foundation for future neurorehabilitation studies that leverage neuroimaging methods, like fNIRS.


Assuntos
Lesões Encefálicas , Equilíbrio Postural , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Masculino , Projetos Piloto , Feminino , Equilíbrio Postural/fisiologia , Adulto , Lesões Encefálicas/fisiopatologia , Lesões Encefálicas/reabilitação , Lesões Encefálicas/diagnóstico por imagem , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Pessoa de Meia-Idade , Encéfalo/diagnóstico por imagem , Encéfalo/fisiopatologia , Exercício Físico/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...