1.
Acta odontol. latinoam ; 34(3): 214-220, 2021. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1383407

RESUMO

ABSTRACT This study evaluated the influence of resin cements and glass ionomers on tensile strength and types of failure of zirconia copings cemented on titanium base abutments. Forty-two samples were prepared, which were formed by a Cone Morse implant, a titanium abutment with the fixing screw, and a zirconia structure made using a CAD/CAM system. The samples (n = 42) were randomly distributed according to the cementing agent: resin-modified glass ionomer cement (RelyX Luting 2), self-adhesive resin cement (RelyX U200), and self-curing resin cement (Multilink N). After cementation of the copings, half of the samples from each group (n = 7) were randomly selected and subjected to thermocycling (5000 cycles). A tensile load test was performed on a universal testing machine until failure occurred (1 mm). In addition, the type of failure was analyzed using the two-way analysis of variance test and Tukey's post-hoc test (α = 0.05). Lower tensile load was observed for the glass ionomer cement (p < 0.001) regardless of the evaluation period. After thermocycling, a significant reduction in tensile load values was verified for both evaluated cements (p = 0.047). For the resin cements, failures were predominantly of the screw fracture type (82.1%) already with the use of glass ionomer cement, and 28.5% of the failures were of an adhesive type between the zirconia coping and the cement. Resin cements have better stability under tensile load compared to resin glass ionomers when cementing zirconia copings on titanium base abutments.


RESUMO Este estudo avaliou influência dos cimentos resinosos e a base de ionômero de vidro na resistência à tração e os tipos de falhas de copings de zircônia cimentados sobre pilares TiBase. Foram confeccionadas 42 amostras, sendo estas formadas por implante cone morse, pilar de titânio (TiBase) com o parafuso de fixação e uma estrutura de zircônia (coping de Zr) confeccionado através do sistema CAD/CAM. As amostras (n =42) foram aleatoriamente distribuídas de acordo com o agente de cimentação: (cimento de ionômero de vidro modificado por resina [RelyXTMLuting2]; cimento resinoso autoadesivo [RelyXTM U200] e cimento resinoso autopolimerizavel (Multilink® N). Após cimentação dos copings, metade das amostras de cada grupo (n = 7) foram aleatoriamente selecionadas e submetidas a termociclagem (5000 ciclos). O Teste de resistência a tração foi realizado em uma máquina de ensaio universal, até que ocorresse a falha (1 mm/min). Adicionalmente, o tipo de falha foi analizado. Os dados foram analisados pelo teste ANOVA two-way e post teste de Tukey's (α = 0.05). Menor média de resistência a tração foi observada para o cimento de ionômero de vidro (p < 0,001) independente do período de avaliação. Após a termociclagem, foi verificada uma redução significativa nos valores de resistênca a tração, para os cimentos avaliados (p=0,047). Para os cimentos resinosos, as falhas foram predominantemente do tipo fratura do parafuso (82,1%) já com o uso do cimento de ionômero de vidro, 28,5% das falhas foram de tipo adesiva entre o coping de Zr e o cimento. Cimentos resinosos apresentam melhor estabilidade na resistência a tração em comparação a ionmeros de vidro resinosos na cimentação de copings de zircônia sobre pilares TiBase.

2.
ROBRAC ; 24(71): 204-208, 20150000. ilus, tab
Artigo em Português | LILACS | ID: biblio-836760

RESUMO

Introdução: A adaptação e a rugosidade superficial dos componentes protéticos podem determinar a longevidade de uma reabilitação e a qualidade dos tecidos periimplantares. Objetivo: Comparar a topografia superficial de intermediários de implantes de quatro diferentes marcas comerciais disponíveis no mercado brasileiro, bem como analisar a adaptação vertical quantitativamente (µm) da interface pilar implante. Materiais e Métodos: Foramutilizados intermediários mini-cônicos pré-fabricados das marcas SIN (GMcS), Neodent (GMcN), Conexão (GMcC) e Bionnovation (GMcB), pilares calcináveis com cinta de cromo cobalto ou titânio SIN (GCS), Neodent (GCN), Conexão (GCC) e Bionnovation (GCB) e implantes do tipo hexágono externo (HE), 3,75mm de diâmetroe plataforma regular de 4,1mm SIN (GIS), Neodent (GIN), Conexão (GIC) e Bionnovation (GIB). Para avaliar a superfície dos intermediários foi utilizada a técnica de interferometria a laser "sem contato". Os dados coletados foram processados pelo Software Mountains Map Universal, Digital Surf, o qual gerou imagens tridimensionais sendo considerados três parâmetros (Sa, Ssk, Sku). A desadaptação vertical na interface intermediário ­ implante foi analisada por meio da utilização do Microscópio Eletrônico de Varredura (MEV). Resultados: Tanto para intermediário cônico quanto o pilar calcinável da empresa SIN® demonstraram menor desajuste entre os componentes protéticos e o implante. O grupo intermediário cônico e pilar calcinável da empresa Bionnovation® foram os que apresentam maior linearidade superficial quando comparados aos demais grupos. Conclusão: Não foi observado padronização da rugosidade superficial nem da adaptação dos pilares protéticos entre as marcas comerciais estudadas, sendo que estas variações podem ocasionar variações na longevidade da reabilitação.


Introduction: The adaptation and the roughness surfasse of the prosthetic componentes can determine the longevity of a rehabilitation as well as quality of peri-implant tissues Objective: compare four different brands which are available in the Brazilian market, and make a comparison of the topography surface of implants intermediates between them. Also, analyze the vertical adjustment (mM) of the implant abutment interface. Materials and Methods: In this project was used pre-manufactured intermediate mini-tapered of those following brands: SIN (GMC), Neodent (GMCN), Connection (GMCC) and Bionnovation (GMcB). Calcinable pillars strap with cobalt chrome or titanium SIN (GCS), Neodent (GCN) , Connection (GCC) and Bionnovation (GCB) and the hexagonal (HE), 3.75 mm in diameter and 4.1 mm SIN (GIS), Neodent (GIN), Connection (GIC) and Bionnovation regular platform implants (GIB). It was used the contactless interferometry laser technique to evaluate the intermediates surface. It was considered three parameters (Sa, Ssk,Sku) to process the data collected, which was done by the Universal Software Mountains Map, Digital Surf software, and has gotten three dimensional images. The vertical misfit on intermediate-implant interface was analyzed by a scanning electron microscope (SEM).Results: The intermediate tapered, also the SIN® burnout pillar have showed up the lower misfit between the prosthetic components and the implant. On the other hand, The Bionnovation® pillar and the intermediate group, in comparison to the other groups, were those with higher surface linearity. It was not found the standardization of the roughness surfaces as well as of the abutments adaptation between trademarks studied. However, we observed that those variations can change the longevity of the rehabilitation.

3.
ROBRAC ; 19(49)ago. 2010. ilus
Artigo em Português | LILACS | ID: lil-556308

RESUMO

OBJETIVO: Avaliar a microinfltração bacteriana na interface entre implantes hexágono externo (HE) e pilares com diferentes tipos de parafusos. MATERIAIS E MÉTODOS: Foram selecionados 20 implantes HE e respectivo pilar, divididos em 2 grupos em função do tipo de parafuso do pilar (n=10). PT: Parafuso de Titânio e PDLC: Parafuso de Diamond Like Carbon (DLC). Uma suspensão bacteriana de Escherichia coli ATCC 35218 foi preparada a uma densidade padrão de 0,5 McFarland para inoculação de 0,5 µL de suspensão no interior dos implantes. Todos os pilares foram apertados com torque de 32 N seguindo recomendações do fabricante. A microinfltração foi avaliada pela análise da claridade da suspensão a cada 24 horas durante 14 dias. Ao final deste período a viabilidade da bactéria foi verifcada. RESULTADOS: Durante o período de acompanhamento nenhuma das amostras apresentou microinfltração bacteriana. Após 14 dias a viabilidade bacteriana foi comprovada. CON-CLUSÃO: Considerando as limitações deste estudo, pode-se concluir que não foi observada a microinfltração bacteriana na interface pilar/ implante nos grupos avaliados e não foi possível estabelecer a infuência de parafusos com diferentes superfícies nesta microinfltração.


The aim of this study was to evaluate the bacterial microleakage at the interface between external hexagon implant (HE) and abutments with diferent types of screws. 20 implants and respective abutments had been selected, divided into 2 groups, depending on the abutment screw (n=10): Titanium screw (PT) and "Diamond Like Carbon" DLC Screw (PDLC). Escherichia coli bacterial suspension ATCC 35218 was prepared at a density 0,5 McFarland standard for suspension inoculation of 0.5 mL in the inner of the implants. All abutments were tightened with 32 N following the manufacturer's recommendations. Microleaka-ge was assessed the clarity of the suspension every 24 hours for 14 days. To the end of this period the viability of the bacterium was verifed. At the time of accompaniment none of the samples presented bacterial microleakage. Microleakage was assessed the clarity of the suspension every 24 hours for 14 days. There-after the viability of bacteria was found. During the monitoring period none of the samples showed bacterial microleakage. After 14 days the bacterial viability was confrmed. Considering the limitations of this study, it can conclude that the Bacterial leakage was not observed in the abutment/implant interface in the evaluated groups and was unable to establish the infuence of screws with diferent surfaces in this microleakage.