Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 192
Filtrar
1.
Front Bioeng Biotechnol ; 12: 1357598, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38988867

RESUMO

Walking is the most common form of how animals move on land. The model organism Drosophila melanogaster has become increasingly popular for studying how the nervous system controls behavior in general and walking in particular. Despite recent advances in tracking and modeling leg movements of walking Drosophila in 3D, there are still gaps in knowledge about the biomechanics of leg joints due to the tiny size of fruit flies. For instance, the natural alignment of joint rotational axes was largely neglected in previous kinematic analyses. In this study, we therefore present a detailed kinematic leg model in which not only the segment lengths but also the main rotational axes of the joints were derived from anatomical landmarks, namely, the joint condyles. Our model with natural oblique joint axes is able to adapt to the 3D leg postures of straight and forward walking fruit flies with high accuracy. When we compared our model to an orthogonalized version, we observed that our model showed a smaller error as well as differences in the used range of motion (ROM), highlighting the advantages of modeling natural rotational axes alignment for the study of joint kinematics. We further found that the kinematic profiles of front, middle, and hind legs differed in the number of required degrees of freedom as well as their contributions to stepping, time courses of joint angles, and ROM. Our findings provide deeper insights into the joint kinematics of walking in Drosophila, and, additionally, will help to develop dynamical, musculoskeletal, and neuromechanical simulations.

2.
Gait Posture ; 112: 134-139, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38772125

RESUMO

BACKGROUND: Enhancing traditional three-dimensional gait analysis with a portable ultrasound device at the lower-limb muscle-tendon level enables direct measurement of muscle and tendon lengths during walking. However, it is important to consider that the size of the ultrasound probe and its attachment on the lower limb may potentially influence gait pattern. RESEARCH QUESTION: What is the effect of wearing an ultrasound probe at the lower limb in adolescents with cerebral palsy and typically developing peers? METHODS: Eleven individuals with cerebral palsy and nine age-matched typically developing peers walking barefoot at their self-selected speed were analyzed. Data collection occurred under three conditions: the reference condition (GAIT), and two conditions involving placement of the ultrasound probe over the distal medial gastrocnemius-Achilles tendon junction (MTJ) and over the medial gastrocnemius mid-belly to capture fascicles (FAS). Data processing included calculating differences between conditions using root mean square error (RMSE) for joint kinematics and comparing them to the overall mean difference. Additionally, Spearman correlations were calculated to examine the relationship between kinematic RMSEs and walking speed. RESULTS: No significant differences in stance phase duration or walking speed were observed among the three conditions. Average RMSEs were below 5° for all parameters and condition comparisons in both groups. In both the TD and CP groups, RMSE values during the swing phase were higher than those during the stance phase for all joints. No significant correlations were found between height or body mass and swing phase RMSEs. In the CP group, there was a significant correlation between joint kinematics RMSEs and differences in walking speed at the hip, knee and ankle joints when comparing the MTJ condition with the GAIT condition. SIGNIFICANCE: This study confirms joint kinematics alterations are smaller than 5° due to wearing to the leg an ultrasound probe during walking.


Assuntos
Paralisia Cerebral , Ultrassonografia , Caminhada , Humanos , Paralisia Cerebral/fisiopatologia , Paralisia Cerebral/diagnóstico por imagem , Adolescente , Masculino , Fenômenos Biomecânicos , Feminino , Caminhada/fisiologia , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiopatologia , Extremidade Inferior/fisiopatologia , Extremidade Inferior/diagnóstico por imagem , Análise da Marcha , Estudos de Casos e Controles , Velocidade de Caminhada/fisiologia , Articulação do Tornozelo/fisiopatologia , Articulação do Tornozelo/diagnóstico por imagem , Criança , Articulação do Joelho/fisiopatologia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/fisiologia , Marcha/fisiologia , Articulação do Quadril/fisiopatologia , Articulação do Quadril/diagnóstico por imagem , Tendão do Calcâneo/diagnóstico por imagem , Tendão do Calcâneo/fisiopatologia
3.
Cureus ; 16(4): e58750, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38779237

RESUMO

Hallux valgus (HV) is a relatively frequent disease caused by a complicated structural malformation of the primary ray. The bunion or middle projection generated by the hallux's lateral displacement and pronation is merely one element of the three-dimensional abnormality. HV may trigger severe discomfort and affect joint kinematics. The specific kinematic cause is still unknown. Female age, gender, restrictive footwear, and heritage are risk indicators. HV frequently coexists along metatarsal adducts, equines contracture, hammertoe imperfection, and pes planus. HV is a frequent foot ailment with multiple, complicated, unknown etiology and course. HV has a preference for females. It is an ongoing condition for which there is no known treatment to reduce or prevent improvement. Fibrodysplasia ossificans progressiva (FOP) is distinguished by hereditary symmetrical HV deformities or symptoms that begin heterotopic calcification that is either idiopathic or caused by trauma, such as subcutaneous immunizations. Localized heterotopic calcification may be preceded by aggravating, recurring soft-tissue enlargements (flare-ups). Heterotopic calcification may happen anywhere; however, it most commonly impacts locations near the axial bone structure during the early/mild phases until advancing to the appendicular skeleton. As an effect of calcification affecting the flexibility of the joints, it might cause limitations in motion. The initial line of therapy focuses on non-surgical methods including night splinting, orthotics, and larger shoes. The next suggested line of action is surgical intervention if conservative therapy fails. Patients have good postoperative tolerance, and bone union often happens six to seven weeks after surgery. Stretching exercises help to restore function by extending shortened soft tissue and restoring range of motion (ROM). The goal of joint mobilization, a form of manual treatment method, is to extend the ligament, the soft tissue surrounding the limited joint, and the restricting joint capsule by applying modest amplitude passive movement to the joint components.

4.
J Neuroeng Rehabil ; 21(1): 67, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38689255

RESUMO

BACKGROUND: Foot and ankle unloading is essential in various clinical contexts, including ulcers, tendon ruptures, and fractures. Choosing the right assistive device is crucial for functionality and recovery. Yet, research on the impact of devices beyond crutches, particularly ankle-foot orthoses (AFOs) designed to unload the ankle and foot, is limited. This study investigates the effects of three types of devices-forearm crutches, knee crutch, and AFO-on biomechanical, metabolic, and subjective parameters during walking with unilateral ankle-foot unloading. METHODS: Twenty healthy participants walked at a self-selected speed in four conditions: unassisted able-bodied gait, and using three unloading devices, namely forearm crutches, iWalk knee crutch, and ZeroG AFO. Comprehensive measurements, including motion capture, force plates, and metabolic system, were used to assess various spatiotemporal, kinematic, kinetic, and metabolic parameters. Additionally, participants provided subjective feedback through questionnaires. The conditions were compared using a within-subject crossover study design with repeated measures ANOVA. RESULTS: Significant differences were found between the three devices and able-bodied gait. Among the devices, ZeroG exhibited significantly faster walking speed and lower metabolic cost. For the weight-bearing leg, ZeroG exhibited the shortest stance phase, lowest braking forces, and hip and knee angles most similar to normal gait. However, ankle plantarflexion after push-off using ZeroG was most different from normal gait. IWalk and crutches caused significantly larger center-of-mass mediolateral and vertical fluctuations, respectively. Participants rated the ZeroG as the most stable, but more participants complained it caused excessive pressure and pain. Crutches were rated with the highest perceived exertion and lowest comfort, whereas no significant differences between ZeroG and iWalk were found for these parameters. CONCLUSIONS: Significant differences among the devices were identified across all measurements, aligning with previous studies for crutches and iWalk. ZeroG demonstrated favorable performance in most aspects, highlighting the potential of AFOs in enhancing gait rehabilitation when unloading is necessary. However, poor comfort and atypical sound-side ankle kinematics were evident with ZeroG. These findings can assist clinicians in making educated decisions about prescribing ankle-foot unloading devices and guide the design of improved devices that overcome the limitations of existing solutions.


Assuntos
Tornozelo , , Caminhada , Humanos , Fenômenos Biomecânicos , Masculino , Caminhada/fisiologia , Feminino , Adulto , Tornozelo/fisiologia , Pé/fisiologia , Órtoses do Pé , Tecnologia Assistiva , Adulto Jovem , Muletas , Estudos Cross-Over , Marcha/fisiologia
5.
Front Bioeng Biotechnol ; 12: 1372669, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38572359

RESUMO

Introduction: Children's walking patterns evolve with age, exhibiting less repetitiveness at a young age and more variability than adults. Three-dimensional gait analysis (3DGA) is crucial for understanding and treating lower limb movement disorders in children, traditionally performed using Optical Motion Capture (OMC). Inertial Measurement Units (IMUs) offer a cost-effective alternative to OMC, although challenges like drift errors persist. Machine learning (ML) models can mitigate these issues in adults, prompting an investigation into their applicability to a heterogeneous pediatric population. This study aimed at 1) quantifying personalized and generalized ML models' performance for predicting gait time series in typically developed (TD) children using IMUs data, 2) Comparing random forest (RF) and convolutional neural networks (CNN) models' performance, 3) Finding the optimal number of IMUs required for accurate predictions. Methodology: Seventeen TD children, aged 6 to 15, participated in data collection involving OMC, force plates, and IMU sensors. Joint kinematics and kinetics (targets) were computed from OMC and force plates' data using OpenSim. Tsfresh, a Python package, extracted features from raw IMU data. Each target's ten most important features were input in the development of personalized and generalized RF and CNN models. This procedure was initially conducted with 7 IMUs placed on all lower limb segments and then performed using only two IMUs on the feet. Results: Findings suggested that the RF and CNN models demonstrated comparable performance. RF predicted joint kinematics with a 9.5% and 19.9% NRMSE for personalized and generalized models, respectively, and joint kinetics with an NRMSE of 10.7% for personalized and 15.2% for generalized models in TD children. Personalized models provided accurate estimations from IMU data in children, while generalized models lacked accuracy due to the limited dataset. Furthermore, reducing the number of IMUs from 7 to 2 did not affect the results, and the performance remained consistent. Discussion: This study proposed a promising personalized approach for gait time series prediction in children, involving an RF model and two IMUs on the feet.

6.
Clin Biomech (Bristol, Avon) ; 114: 106233, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38531152

RESUMO

BACKGROUND: Sacroiliac joints are affected by mechanical environments; the joints are formed under mechanical stimulation, receive impact of walking between the upper and lower parts of the bodies and can be a cause of pain due to non-physiological loads. However, there are so far very few studies that reviewed biomechanics of physiological and pathological sacroiliac joints. This review article aims to describe the current sacroiliac joint biomechanics. METHODS: Previous original papers have been summarized based on three categories: articular surface structure, sacroiliac joint motion and sacroiliac joint dysfunction and treatments. FINDINGS: Although the articular surface morphologies vary greatly from individual to individual, many researchers have tried to classify the joints into several types. It has been suggested that the surface morphologies may not change regardless of joint dysfunction, however, the relationship between the joint structure and pain are still unclear. The range of sacroiliac joint motion is demonstrated to be less than 1 mm and there is no difference between physiological and pathological joints. The sacroiliac joint absorbs shock within the pelvis by the joint structures of pelvic morphology, ligaments and fat tissues. The morphology and motion of the sacroiliac joints may be optimized for upright bipedal walking. INTERPRETATION: There is no doubt that pelvic mechanical environments affect pain induction and treatment; however, no one has yet provided a concrete explanation. Future research could help develop treatments based on sacroiliac joint biomechanics to support joint function.


Assuntos
Artropatias , Articulação Sacroilíaca , Humanos , Articulação Sacroilíaca/fisiologia , Pelve/fisiologia , Movimento (Física) , Ligamentos , Dor , Fenômenos Biomecânicos
7.
Front Bioeng Biotechnol ; 12: 1270181, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38532878

RESUMO

Analyzing human body movement is a critical aspect of biomechanical studies in road safety. While most studies have traditionally focused on assessing the head-neck system due to the restraint provided by seat belts, it is essential to examine the entire pelvis-thorax-head kinematic chain when these body regions are free to move. The absence of restraint systems is prevalent in public transport and is also being considered for future integration into autonomous vehicles operating at low speeds. This article presents an experimental study examining the movement of the pelvis, thorax and head of 18 passengers seated without seat belts during emergency braking in an autonomous bus. The movement was recorded using a video analysis system capturing 100 frames per second. Reflective markers were placed on the knee, pelvis, lumbar region, thorax, neck and head, enabling precise measurement of the movement of each body segment and the joints of the lumbar and cervical spine. Various kinematic variables, including angles, displacements, angular velocities and accelerations, were measured. The results delineate distinct phases of body movement during braking and elucidate the coordination and sequentiality of pelvis, thorax and head rotation. Additionally, the study reveals correlations between pelvic rotation, lumbar flexion, and vertical trunk movement, shedding light on their potential impact on neck compression. Notably, it is observed that the elevation of the C7 vertebra is more closely linked to pelvic tilt than lumbar flexion. Furthermore, the study identifies that the maximum angular acceleration of the head and the maximum tangential force occur during the trunk's rebound against the seatback once the vehicle comes to a complete stop. However, these forces are found to be insufficient to cause neck injury. While this study serves as a preliminary investigation, its findings underscore the need to incorporate complete trunk kinematics, particularly of the pelvis, into braking and impact studies, rather than solely focusing on the head-neck system, as is common in most research endeavors.

8.
J Biomech ; 165: 112027, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38430608

RESUMO

The assessment of gait performance using quantitative measures can yield crucial insights into an individual's health status. Recently, computer vision-based human pose estimation has emerged as a promising solution for markerless gait analysis, as it allows for the direct extraction of gait parameters from videos. This study aimed to compare the lower extremity kinematics and spatiotemporal gait parameters obtained from a single-camera-based markerless method with those acquired from a marker-based motion tracking system across a healthy population. Additionally, we investigated the impact of camera viewing angles and distances on the accuracy of the markerless method. Our findings demonstrated a robust correlation and agreement (Rxy > 0.75, Rc > 0.7) between the markerless and marker-based methods for most spatiotemporal gait parameters. We also observed strong correlations (Rxy > 0.8) between the two methods for hip flexion/extension, knee flexion/extension, hip abduction/adduction, and hip internal/external rotation. Statistical tests revealed significant effects of viewing angles and distances on the accuracy of the identified gait parameters. While the markerless method offers an alternative for general gait analysis, particularly when marker use is impractical, its accuracy for clinical applications remains insufficient and requires substantial improvement. Future investigations should explore the potential of the markerless system to measure gait parameters in pathological gaits.


Assuntos
Análise da Marcha , Marcha , Humanos , Análise da Marcha/métodos , Articulação do Joelho , Extremidade Inferior , Movimento (Física) , Fenômenos Biomecânicos
9.
Comput Biol Med ; 171: 108101, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38340440

RESUMO

BACKGROUND AND OBJECTIVE: Motion analysis is crucial for effective and timely rehabilitative interventions on people with motor disorders. Conventional marker-based (MB) gait analysis is highly time-consuming and calls for expensive equipment, dedicated facilities and personnel. Markerless (ML) systems may pave the way to less demanding gait monitoring, also in unsupervised environments (i.e., in telemedicine). However,scepticism on clinical usability of relevant outcome measures has hampered its use. ML is normally used to analyse treadmill walking, which is significantly different from the more physiological overground walking. This study aims to provide end-users with instructions on using a single-camera markerless system to obtain reliable motion data from overground walking, while clinicians will be instructed on the reliability of obtained quantities. METHODS: The study compares kinematics obtained from ML systems to those concurrently obtained from marker-based systems, considering different stride counts and subject positioning within the capture volume. RESULTS: The findings suggest that five straight walking trials are sufficient for collecting reliable kinematics with ML systems. Precision on joint kinematics decreased at the boundary of the capture volume. Excellent correlation was found between ML and MB systems for hip and knee angles (0.92

Assuntos
Análise da Marcha , Marcha , Humanos , Reprodutibilidade dos Testes , Marcha/fisiologia , Caminhada/fisiologia , Articulação do Joelho/fisiologia , Fenômenos Biomecânicos
10.
J Biomech ; 164: 111973, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38325192

RESUMO

Computational studies of total knee arthroplasty (TKA) often focus on either joint mechanics (kinematics and forces) or implant fixation mechanics. However, such disconnect between joint and fixation mechanics hinders our understanding of overall TKA biomechanical function by preventing identification of key relationships between these two levels of TKA mechanics. We developed a computational workflow to holistically assess TKA biomechanics by integrating musculoskeletal and finite element (FE) models. For our initial study using the workflow, we investigated how tibiofemoral contact mechanics affected the risk of failure due to debonding at the implant-cement interface using the four available subjects from the Grand Challenge Competitions to Predict In Vivo Knee Loads. We used a musculoskeletal model with a 12 degrees-of-freedom knee joint to simulate the stance phase of gait for each subject. The computed tibiofemoral joint forces at each node in contact were direct inputs to FE simulations of the same subjects. We found that the peak risk of failure did not coincide with the peak joint forces or the extreme tibiofemoral contact positions. Moreover, despite the consistency of joint forces across subjects, we observed important variability in the profile of the risk of failure during gait. Thus, by a combined evaluation of the joint and implant fixation mechanics of TKA, we could identify subject-specific effects of joint kinematics and forces on implant fixation that would otherwise have gone unnoticed. We intend to apply our workflow to evaluate the impact of implant alignment and design on TKA biomechanics.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Humanos , Fenômenos Biomecânicos , Fluxo de Trabalho , Amplitude de Movimento Articular , Articulação do Joelho/cirurgia
11.
N Am Spine Soc J ; 17: 100306, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38293567

RESUMO

Background: Adult spinal deformity patients (ASD) experience altered spinal alignment affecting spatiotemporal parameters and joint kinematics. Differences in spinal deformity between patients with symptomatic idiopathic scoliosis (ID-ASD) and patients with "de novo" scoliosis (DN-ASD) may affect gait characteristics differently. This study aims to compare gait characteristics between ID-ASD, DN-ASD, and asymptomatic healthy matched controls. Methods: In this observational case-control study, ID-ASD (n = 24) and DN-ASD (n = 26) patients visiting the out-patient spine clinic and scheduled for long-segment spinal fusion were included. Patients were matched, based on age, gender, leg length and BMI, with asymptomatic healthy controls. Gait was measured at comfortable walking speed on an instrumented treadmill with 3D motion capture system. Trunk, pelvic and lower extremities range of motion (ROM) and spatiotemporal parameters (SPT) are presented as median (first and thirds quartile). Independent t-test or Mann-Whitney U test was used to compare ID-ASD, DN-ASD and controls. Statistical Parametric Mapping (independent t-test) was used to compare 3D joint kinematics. Results: DN-ASD patients walk with increased anterior trunk tilt during the whole gait cycle compared with ID-ASD patients and controls. ID-ASD walk with decreased trunk lateroflexion compared with DN-ASD and controls. DN-ASD showed decreased pelvic obliquity and -rotation, increased knee flexion, and decreased ankle plantar flexion. ID-ASD and DN-ASD displayed decreased trunk, pelvic and lower extremity ROM compared with controls, but increased pelvic tilt ROM. ID-ASD patients walked with comparable SPT to controls, whereas DN-ASD patients walked significantly slower with corresponding changes in SPT and wider steps. Conclusions: DN-ASD patients exhibit distinct alterations in SPT and kinematic gait characteristics compared with ID-ASD and controls. These alterations seem to be predominantly influenced by sagittal spinal malalignment and kinematic findings in ASD patients should not be generalized as such, but always be interpreted with consideration for the nature of the ASD.

12.
Biomed Mater Eng ; 35(1): 53-63, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37545208

RESUMO

BACKGROUND: The human sacroiliac joint (SIJ) in vivo is exposed to compressive and shearing stress environment, given the joint lines are almost parallel to the direction of gravity. The SIJ supports efficient bipedal walking. Unexpected or unphysiological, repeated impacts are believed to cause joint misalignment and result in SIJ pain. In the anterior compartment of the SIJ being synovial, the articular surface presents fine irregularities, potentially restricting the motion of the joints. OBJECTIVE: To clarify how the SIJ articular surface affects the resistance of the motion under physiological loading. METHODS: SIJ surface models were created based on computed tomography data of three patients and subsequently 3D printed. Shear resistance was measured in four directions and three combined positions using a customized setup. In addition, repositionability of SIJs was investigated by unloading a shear force. RESULTS: Shear resistance of the SIJ was the highest in the inferior direction. It changed depending on the direction of the shear and the alignment position of the articular surface. CONCLUSION: SIJ articular surface morphology is likely designed to accommodate upright bipedal walking. Joint misalignment may in consequence increase the risk of subluxation.


Assuntos
Articulação Sacroilíaca , Posição Ortostática , Humanos , Articulação Sacroilíaca/diagnóstico por imagem , Articulação Sacroilíaca/anatomia & histologia , Articulação Sacroilíaca/fisiologia , Movimento (Física) , Estresse Mecânico , Amplitude de Movimento Articular/fisiologia
13.
J Mot Behav ; 56(1): 22-29, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37429586

RESUMO

Postural control is influenced by cognition. In most studies, variability of motor output has been considered regardless of variability in patterns of joint coordination. Uncontrolled manifold framework has been applied to decompose the joint's variance in two components. The first component leaves position of the center of mass in anterior-posterior direction (CoMAP) unchanged (VUCM) while the second component is in charge of variations of CoM (VORT). In this study, 30 healthy young volunteers were recruited. The experimental protocol consisted of three random conditions: quiet standing on a narrow wooden block without a cognitive task (NB), quiet standing on a narrow wooden block with an easy cognitive task (NBE), and quiet standing on a narrow wooden block with a difficult cognitive task (NBD). Results showed that CoMAP sway in NB condition was higher than both NBE and NBD conditions (p = .001). VORT in NB condition was higher than NBE and NBD conditions (p = .003). VORT in NB condition was higher than NBE and NBD conditions (p = .003). VUCM was unchanged in all conditions (p = 1.00) and synergy index in NB condition was smaller than NBE and NBD conditions (p = .006). These results showed that postural synergies increased under dual-task conditions.


Assuntos
Cognição , Equilíbrio Postural , Humanos , Posição Ortostática
14.
Clin Biomech (Bristol, Avon) ; 111: 106158, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38061205

RESUMO

BACKGROUND: The interplay between the medial gastrocnemius muscle and the Achilles tendon is crucial for efficient walking. In cerebral palsy, muscle and tendon remodelling alters the role of contractile and elastic components. The aim was to investigate the length changes of medial gastrocnemius belly and fascicles, and Achilles tendon to understand their interplay to gait propulsion in individuals with cerebral palsy. METHODS: Twelve young individuals with cerebral palsy and 12 typically developed peers were assessed during multiple gait cycles using 3D gait analysis combined with a portable ultrasound device. By mapping ultrasound image locations into the shank reference frame, the medial gastrocnemius belly, fascicle, and Achilles tendon lengths were estimated throughout the gait cycle. Participants with cerebral palsy were classified into equinus and non-equinus groups based on their sagittal ankle kinematics. FINDINGS: In typically developed participants, the Achilles tendon undertook most of the muscle-tendon unit lengthening during stance, whereas in individuals with cerebral palsy, this lengthening was shared between the medial gastrocnemius belly and Achilles tendon, which was more evident in the equinus group. The lengthening behaviour of the medial gastrocnemius fascicles resembled that of the Achilles tendon in cerebral palsy. INTERPRETATION: The findings revealed similar length changes of the medial gastrocnemius fascicles and Achilles tendon, highlighting the enhanced role of the muscle in absorbing energy during stance in cerebral palsy. These results, together with the current knowledge of increased intramuscular stiffness, suggest the exploitation of intramuscular passive forces for such energy absorption.


Assuntos
Tendão do Calcâneo , Paralisia Cerebral , Humanos , Tendão do Calcâneo/diagnóstico por imagem , Tendão do Calcâneo/fisiologia , Fenômenos Biomecânicos , Paralisia Cerebral/complicações , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiologia , Marcha/fisiologia , Ultrassonografia/métodos
15.
J Biomech ; 162: 111885, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38039920

RESUMO

Improved understanding is required on how hip fracture risk is influenced by landing configuration. We examined how hip impact dynamics was affected by hip joint kinematics during simulated sideways falls. Twelve young adults (7 males, 5 females) of mean age 23.5 (SD = 1.5) years, participated in pelvis release experiments. Trials were acquired with the hip flexed 15° and 30° for each of three hip rotations: +15° ("external rotation"), 0°, and -15° ("internal rotation"). During falls, force-deformation data of the pelvis were recorded. Outcome variables included the peak hip impact force (Fexperimental) and effective stiffness of the pelvis (k1st, ksecant, and kms) determined with different methods suggested in literature, and predicted hip impact force during a fall from standing height (F1st, Fsecant and Fms). The two-way repeated-measures ANOVA was used to test whether these variables were associated with hip joint angles. The Fexperimental, ksecant and Fsecant were associated with hip rotation (F = 5.587, p = 0.005; F = 9.278, p < 0.0005; F = 5.778, p = 0.004, respectively), and 15 %, 31 % and 17 % smaller in 15° external than internal rotation (848 versus 998 N; 24.6 versus 35.6 kN/m; 2,637 versus 3,170 N, respectively). However, none of the outcome variables were associated with hip flexion (p > 0.05). Furthermore, there were no interactions between the hip rotation and flexion for all outcome variables (p > 0.05). Our results provide insights on hip impact dynamics, which may help improve a hip model to assess hip fracture risk during a fall.


Assuntos
Fraturas do Quadril , Quadril , Masculino , Feminino , Adulto Jovem , Humanos , Adulto , Fenômenos Biomecânicos , Pelve , Articulação do Quadril
16.
J Hand Surg Am ; 49(1): 8-14, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37978963

RESUMO

PURPOSE: The purpose of the study was to determine if the sphericity of the thumb metacarpophalangeal (MCP) joint influences the joint's rotational axis (RA) and elongation patterns of the ulnar collateral ligament (UCL). METHODS: Ulnar collateral ligament origins and attachments of 28 fresh-frozen cadaveric thumbs were marked with a radiopaque marker. Lateral radiographs were obtained in neutral and 20°, 40°, and 60° of flexion. The dorsal and palmar joint gap and the length of four different UCL portions were digitally measured in all flexion states. The RA was determined by the intersection of the midshaft axis of the proximal phalanx in neutral and flexion states. Sphericity of the MCP joint was assessed using morphometric parameters. Joints were grouped as round or flat. Differences in all measured parameters between groups were analyzed. RESULTS: During flexion, the dorsal joint gap increased by 322% in flat joints and 163% in round joints. The palmar joint gap decreased to 45% in flat joints and to 87% in round joints. The RA was at 29% of metacarpal height and 96% of metacarpal length in flat joints and at 40% of height and 86% of length in round joints. Maximum UCL elongation (111%) was noted at 40° flexion in the dorsal proper UCL in flat joints and at 60° flexion in the accessory UCL (117%) in round joints. CONCLUSIONS: In flat MCP joints, the RA is more dorsal and distal in the metacarpal head compared to round joints, resulting in a hinged flexion motion. Elongation of the UCL is highest at end flexion in round joints and highest at midflexion in flat joints. CLINICAL RELEVANCE: The different kinematics of flat and round MCP joints may contribute to the understanding of the pathophysiology of UCL ruptures. The propensity of this injury and the position in which they occur may be affected by the MCP joint morphology.


Assuntos
Ligamento Colateral Ulnar , Ligamentos Colaterais , Humanos , Polegar , Ligamento Colateral Ulnar/diagnóstico por imagem , Ligamento Colateral Ulnar/lesões , Ligamentos Colaterais/lesões , Fenômenos Biomecânicos , Articulação Metacarpofalângica
17.
Braz. j. med. biol. res ; 57: e13124, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1528105

RESUMO

This study investigated the effects of a foot core intervention on the coordination of foot joints in recreational runners. This was a secondary analysis from a randomized controlled trial conducted with 87 recreational runners allocated to the control group (CG), which followed a placebo lower limb stretching protocol, or the intervention group (IG), which underwent an 8-week (3 times/week) foot core training. The participants ran on a force-instrumented treadmill at a self-selected speed (9.5-10.5 km/h) while the foot segment motion was captured. The vector coding technique was used to assess inter-joint coordination for four selected coupled segment and joint angles. The coordination patterns of the calcaneus and midfoot (CalMid) and midfoot and metatarsus (MidMet) joint pairs were affected. In the frontal plane, IG showed an in-phase with proximal dominancy coordination at heel strike, with a decrease in its frequency after the training (P=0.018), suggesting a longer foot supination. Additionally, IG showed an anti-phase with distal dominancy pattern at early stance compared to CG due to a smaller but earlier inversion of the CalMid-MidMet pair (P=0.020). The intervention also had an effect on the transverse plane of the CalMid-MidMet pair, with IG showing a significantly greater frequency of anti-phase coordination with proximal dominancy during propulsion than CG (P=0.013), probably due to a reduction in the CalMid abduction. Overall, the results suggested that the foot core intervention reduces the occurrence of running-related injuries by increasing the resistance to calcaneus pronation and building a more rigid and efficient lever during push-off.

18.
J Phys Ther Sci ; 35(12): 777-782, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38075518

RESUMO

[Purpose] Ankle foot orthosis (AFO) is widely used to regain gait function after injuries and/or stroke; however, limited information is currently available on their effects. We herein examined the effects of three-hour immobilization with AFO on corticospinal excitability and ankle joint movement during gait in healthy volunteers. [Participants and Methods] The participants comprised of seven healthy volunteers. Corticospinal excitability and ankle joint excursions were evaluated before and after three hours of immobilization with left limb AFO. We measured motor evoked potentials in the tibialis anterior (TA) and gastrocnemius (Ga) muscles induced by transcranial magnetic stimulation. In a kinematic analysis, we focused on transition points, such as the timing from dorsiflexion to plantarflexion of the ankle joint and/or vice versa, during gait. [Results] Corticospinal excitability in TA and Ga both significantly decreased. During the normalized gait cycle (GC), ankle angles showed less dorsiflexion at 0% GC and 100% GC, and during loading response and mid-swing and terminal swing phases. Furthermore, less plantarflexion was observed during the initial swing phase. [Conclusion] This study showed that short-term ankle joint immobilization with AFO induces a significant decrease in corticospinal excitability and has an effect on ankle joint excursion during gait. Further studies are needed on the effects of long-term immobilization by AFO.

19.
Arch Bone Jt Surg ; 11(11): 711-716, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38058970

RESUMO

Objectives: The study aimed at discovering the existing differences in lower limb joints' kinematics, and EMG signals of 4 particular muscles of the ankle joint during gait, between normal subjects and patients with bilateral triple arthrodesis. Methods: In this research, a 3D motion analysis system was used and joints' angles were calculated using a MATLAB code, and based on the data collected from markers movements, for patients with bilateral triple arthrodesis and normal subjects. Moreover, the EMG signals of ankle muscles in each subject, and the graphs of mean plus and minus standard deviation of lower limb joint angles and muscles' EMG were calculated by MATLAB. Results: In all patients, an initial ankle eversion and valgus deformity were observed in their knee joints. In addition, for all patients, the maximum knee extension was less than that of the average value of the normal subjects. Furthermore, the results of the electromyography showed that, in all patients, delay occurred in gastrocnemius and soleus muscles in maximum contraction in their EMG signals. Besides, during the early stance phase of gait cycles, the mean value of EMG of peroneus brevis muscle for patients was more than that of normal subjects. Conclusion: Atrophy of four ankle muscles including (soleus, lateral gastrocnemius, tibialis anterior and peroneus brevis), also limitation of joints movement were observed in patients, compared to normal subjects. Based on the results of this work, in order to reduce further musculoskeletal disorders in patients who underwent bilateral triple arthrodesis surgery, there is a serious need to use physiotherapy after the surgery.

20.
Sensors (Basel) ; 23(24)2023 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-38139644

RESUMO

Accuracy validation of gait analysis using pose estimation with artificial intelligence (AI) remains inadequate, particularly in objective assessments of absolute error and similarity of waveform patterns. This study aimed to clarify objective measures for absolute error and waveform pattern similarity in gait analysis using pose estimation AI (OpenPose). Additionally, we investigated the feasibility of simultaneous measuring both lower limbs using a single camera from one side. We compared motion analysis data from pose estimation AI using video footage that was synchronized with a three-dimensional motion analysis device. The comparisons involved mean absolute error (MAE) and the coefficient of multiple correlation (CMC) to compare the waveform pattern similarity. The MAE ranged from 2.3 to 3.1° on the camera side and from 3.1 to 4.1° on the opposite side, with slightly higher accuracy on the camera side. Moreover, the CMC ranged from 0.936 to 0.994 on the camera side and from 0.890 to 0.988 on the opposite side, indicating a "very good to excellent" waveform similarity. Gait analysis using a single camera revealed that the precision on both sides was sufficiently robust for clinical evaluation, while measurement accuracy was slightly superior on the camera side.


Assuntos
Inteligência Artificial , Análise da Marcha , Fenômenos Biomecânicos , Extremidade Inferior , Movimento (Física) , Marcha
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...