Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 178
Filtrar
1.
Clin Toxicol (Phila) ; : 1-3, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39007755

RESUMO

BACKGROUND: Ethylene glycol poisoning causes metabolic acidosis, organ injury, and death. Ethylene glycol testing is unavailable in many areas. Our laboratory uses an automated glycerol dehydrogenase enzymatic assay to screen for ethylene glycol. We sought to determine how often ethylene glycol results were available within 12 h of the first dose of fomepizole. METHODS: Records from a single poison center were reviewed from December 2016 to December 2019. Cases were identified by searching for cases that received fomepizole. Outcomes included whether results were available within 12 h, and the turnaround time from time of laboratory order to result. RESULTS: Of the 125 cases of suspected toxic alcohol poisoning identified, 73 had screening for ethylene glycol by enzymatic assay. Results were available within 12 h of the initial fomepizole dose in 58 (79%) cases with a median turnaround time of 391 min. DISCUSSION: We have demonstrated clinically acceptable turnaround times using an automated screening ethylene glycol assay. The major limitations include lack of approval for this test at this time, the use of voluntarily reported poison center data, and lack of assessment of patient outcomes. CONCLUSION: Enzymatic screening for ethylene glycol yielded results within 12 h in 79% of cases.

2.
Cureus ; 16(5): e60158, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38868295

RESUMO

This review paper provides an overview of the risk factors and laboratory testing for red blood cell (RBC) alloimmunization in pregnancy. RBC alloimmunization is a significant medical issue that can cause haemolytic disease of the fetus and newborn (HDFN), leading to neonatal morbidity and mortality. Current HDFN prophylaxis targets only Rhesus D (RhD) alloimmunization, with no effective measures to prevent alloimmunization to other RBC antigen groups. Several factors can increase the risk of developing RBC alloimmunization during pregnancy, including fetomaternal haemorrhage, RBC and maternal genetic status, and previous transfusions. Identifying these risk factors is essential to execute the appropriate management strategies to minimize the risk of HDFN. The review also discusses the laboratory methods and overview of pregnancy management. The paper highlights the importance of identifying and managing the risk factors for RBC alloimmunization in pregnancy to minimize the risk of HDFN and improve neonatal outcomes.

3.
Diagn Microbiol Infect Dis ; 110(1): 116402, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38878340

RESUMO

Due to the limitations of traditional laboratory methods (TMs), identification of causative pathogens of numerous pulmonary infections (PIs) remains difficult. This study evaluated the value of metagenomic next generation sequencing (mNGS) in the identification of various respiratory pathogens. A total of 207 patients with TMs and mNGS data were collected for this retrospective study. TMs included sputum culture, blood, and bronchoalveolar lavage fluid (BALF) analysis, or polymerase chain reaction analysis of throat swabs. Otherwise, BALF was collected and analyzed using mNGS. For bacterial pathogens, sensitivities of mNGS as compared to TMs were 76.74 % and 58.14 % (P=0.012). For fungal pathogens, the detection rate of mNGS sensitivity was higher as compared to that of TMs (93.68 % vs 22.11 %; P<0.001). The positive predictive value and negative predictive value were also greater for mNGS. Use of mNGS for BALF analysis offers good specificity and thus facilitates to the clinical diagnosis of PIs.

4.
Ann Clin Biochem ; : 45632241252006, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38631810

RESUMO

BACKGROUND: Parametric regression analysis is widely used in methods comparisons and more recently in checking the concordance of test results following receipt of new reagent lots. The greater frequency of reagent-lot evaluations increases pressure to detect bias with smallest possible sample sizes (i.e. smallest consumption of time and resources). This study revisits bias detection using the joint slope, intercept confidence region as an alternative to slope and intercept confidence intervals. METHODS: Four cases were considered representing constant errors, proportional errors (constant CV) and two more complicated error patterns typical of immunoassays. Maximum:minimum range ratios varied from 2:1 to 2000:1. After setting a maximum tolerable difference a series of slope, intercept combinations, each of which predicted the critical difference, were systematically evaluated in simulations which determined the minimum sample size required to detect the difference, firstly using slope, intercept confidence intervals and secondly using the joint slope, intercept confidence region. RESULTS: At small to moderate range ratios, bias detection by joint confidence region required greatly reduced sample sizes to the extent that it should encourage reagent-lot evaluations or, alternatively, transform those already routinely performed into considerably less costly exercises. CONCLUSIONS: While some software is available to calculate joint confidence regions in real-life analyses, shifting this testing method into the mainstream will require a greater number of software developers incorporating the necessary code into their regression programs. The computer program used to conduct this study is freely available and can be used to model any laboratory test.

5.
Ann Clin Biochem ; : 45632241239805, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38428927

RESUMO

Background: Robust preanalytical and analytical processes are critical for the detection of cryoproteins. There is significant variation in practice in the detection, analysis and reporting. Results: A survey in 2018 of 137 laboratories participating in the UK National External Quality Assessment Service (UK NEQAS) (6) quality control program showed significant variation in the laboratory processes which highlighted the need for standardisation of the detection, analysis and reporting of cryoglobulins.Conclusion: The first available EQA scheme aiming to harmonise practice for cryoprotein testing has been developed by UK NEQAS and laboratories should participate in an appropriate EQA scheme to fulfil requirements for ISO accreditation.

6.
Mini Rev Med Chem ; 24(1): 3-25, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37073153

RESUMO

BACKGROUND: Natural products have optical activities with unusual structural characteristics or specific stereoselectivity, mostly including spiro-ring systems or quaternary carbon atoms. Expensive and time-consuming methods for natural product purification, especially natural products with bioactive properties, have encouraged chemists to synthesize those compounds in laboratories. Due to their significant role in drug discovery and chemical biology, natural products have become a major area of synthetic organic chemistry. Most medicinal ingredients available today are healing agents derived from natural resources, such as plants, herbs, and other natural products. METHODS: Materials were compiled using the three databases of ScienceDirect, PubMed, and Google Scholar. For this study, only English-language publications have been evaluated based on their titles, abstracts, and full texts. RESULTS: Developing bioactive compounds and drugs from natural products has remained challenging despite recent advances. A major challenge is not whether a target can be synthesized but how to do so efficiently and practically. Nature has the ability to create molecules in a delicate but effective manner. A convenient method is to imitate the biogenesis of natural products from microbes, plants, or animals for synthesizing natural products. Inspired by the mechanisms occurring in the nature, synthetic strategies facilitate laboratory synthesis of natural compounds with complicated structures. CONCLUSION: In this review, we have elaborated on the recent syntheses of natural products conducted since 2008 and provided an updated outline of this area of research (Covering 2008-2022) using bioinspired methods, including Diels-Alder dimerization, photocycloaddition, cyclization, and oxidative and radical reactions, which will provide an easy access to precursors for biomimetic reactions. This study presents a unified method for synthesizing bioactive skeletal products.


Assuntos
Produtos Biológicos , Animais , Produtos Biológicos/química , Biomimética , Oxirredução , Carbono , Descoberta de Drogas
7.
Ann Clin Biochem ; : 45632231216596, 2023 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-37944991

RESUMO

BACKGROUND: Cell-free DNA (cfDNA) is free DNA found in circulating blood that originates from apoptosis or necrosis, and elevated cfDNA concentrations have been reported in cancers and other diseases. METHODS: In this study, the concentrations and fragment distributions of plasma cfDNA were preliminary investigated in elderly (n = 1) and pediatric (n = 1) patients with acute promyelocytic leukemia (APL) treated with arsenic trioxide (ATO). RESULTS: A slight increase in cfDNA concentrations was observed in the APL patients compared with healthy controls. The change in plasma cfDNA concentrations corresponded to the change in plasma arsenic concentrations during ATO treatment. The fragment distribution pattern did not differ before and during treatment. Three ladder fragments were observed in part of the cfDNA in the second consolidation therapy in an elderly APL patient and the first consolidation therapy of a pediatric APL patient, while two fragments were observed in all other treatment periods. Moreover, APL-related gene mutations were successfully genotyped from plasma cfDNA by using polymerase chain reaction-based methods and these results are consistent with those from leukocytes. CONCLUSION: This study is the first to report the concentrations and fragment patterns of cfDNA from APL patients treated with ATO. The results suggested that plasma cfDNA concentration in APL patients increased with ATO treatment and that cfDNA is released mainly via neutrophil extracellular traps (and/or necrosis) in addition to apoptosis. To confirm whether cfDNA concentrations and fragment patterns can be used as a biomarker for APL treated with ATO, further accumulative data are needed.

8.
Clin Chest Med ; 44(4): 743-755, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37890913

RESUMO

Nontuberculous mycobacteria (NTM) typically cause opportunistic pulmonary infections and reliable laboratory results can assist with diagnosis of disease. Microscopy can detect acid-fast bacilli from specimens though it has poor sensitivity. Solid and liquid culture are used to grow NTM, which are identified by molecular or protein-based assays. Because culture has a long turnaround time, some assays are designed to identify NTM directly from sputum specimens. When indicated, phenotypic susceptibility testing should be performed by broth microdilution as per the guidelines from the Clinical Laboratory Standards Institute. Genotypic susceptibility methods may be used to decrease the turnaround time for some antimicrobials.


Assuntos
Infecções por Mycobacterium não Tuberculosas , Micobactérias não Tuberculosas , Humanos , Infecções por Mycobacterium não Tuberculosas/diagnóstico , Infecções por Mycobacterium não Tuberculosas/tratamento farmacológico , Infecções por Mycobacterium não Tuberculosas/microbiologia , Pulmão , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico
9.
Ann Clin Biochem ; : 45632231202652, 2023 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-37678836

RESUMO

BACKGROUND: Neuroendocrine neoplasms (NENs) are a heterogeneous group of rare diseases with varied aggressiveness originating from endocrine cells belonging to the diffuse endocrine system and most often produce and secrete chromogranin A (CgA). CgA in plasma is therefore used to screen, diagnose, and monitor for NENs in both adults and children with sporadic or familial NENs. METHODS: Plasma CgA was measured using the Brahms Kryptor assay in 268 healthy children/adolescents; 85 children were tested as part of a familial cancer screening program and 183 additional children younger than 20 years of age underwent screening for allergies. Repeated measurements (month - years) was used to calculate the intra-individual variation. The dataset was analysed in R using the referenceInterval package. RESULTS: The plasma CgA concentration decreased with age and was 32-118 µg/L for children aged 0-3 years, 18-85 µg/L for children aged 4-13 years, and 6-79 µg/L for adolescents aged 14-19 years. Earlier reported CgA reference intervals for adults have upper limits from 88 to 102 µg/L while no lower limits have been reported. The median for the three groups were 78, 51, and 39 µg/L, respectively. The median intra-individual variation was 14% (25%-centile 9.4%/75%-centile 21%). CONCLUSIONS: The reference interval will be useful when screening, diagnosing, and monitoring children for NENs respecting the limitations plasma CgA has.

10.
Ann Clin Biochem ; 60(2): 117-125, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36604773

RESUMO

BACKGROUND: Severe hyperammonaemia is associated with significant morbidity and mortality. Rapid analysis and reporting of ammonia results is essential to prevent patient harm. The aim was to investigate the laboratory sample acceptance criteria, ammonia analysis and the reporting of ammonia results. METHODS: A questionnaire was distributed to clinical biochemistry laboratories in the United Kingdom. The results were collated and compared to updated best practice guidelines on hyperammonaemia issued by the Metabolic Biochemistry Network (MetBio.net). RESULTS: Seventy-six laboratories responded to the audit questionnaire. Although 83% laboratories are aware of the updated MetBio.net hyperammonaemia guidelines, most laboratories continue to reject samples for ammonia that are 'too old' for analysis (64%), haemolysed (72%) or not sent on ice (24%). Rapid ammonia analysis is available in 96% laboratories and all laboratories offer ammonia analysis on a 24/7 basis. Nearly all laboratories had implemented critical phoning limits for ammonia. CONCLUSIONS: Laboratories are rejecting samples for ammonia analysis that have not been collected/transported in an optimal manner. Laboratories should review their sample acceptance criteria for ammonia and accept all samples in order to avoid delaying the diagnosis and management of hyperammonaemia.


Assuntos
Hiperamonemia , Humanos , Hiperamonemia/diagnóstico , Amônia , Inquéritos e Questionários , Laboratórios , Reino Unido
11.
Ann Clin Biochem ; 60(3): 169-176, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36658091

RESUMO

AIM: A digital rectal examination (DRE) during routine assessment for patients with abdominal symptoms provides an opportunity to obtain faeces from the glove for faecal immunochemical testing (FIT). Here, we compared sampling via DRE to the standard faecal sampling by patients. METHOD: Patients were recruited to a prospective observational cohort study between July 2019 and March 2020. Patients provided a sample for the FOB Gold Wide® which was compared to a further sample taken at clinic via DRE. Clinicians reported whether they obtained a 'good' sample filling all the grooves, a 'poor' sample filling some of the grooves or no faecal sample. Cohen's kappa was used to compare percentage agreement around a negative threshold of <10 µg haemoglobin/g of faeces. Sensitivity for serious bowel disease (SBD) was calculated. RESULTS: Of 596 patients who underwent attempted DRE sampling, there were 258 (43.3%) 'good' samples, 117 (19.6%) 'poor' samples and 221 (37.1%) with no sample to wipe in the grooves. Cohen's kappa dropped from 0.70 to 0.30 for the 'good' and 'poor' samples, respectively. Of those with DRE samples and definitive diagnostic outcomes, the sensitivity for SBD dropped significantly from 76.0% to 41.7% between 'good' and 'poor' samples, respectively (p = 0.041). CONCLUSIONS: A 'good' sample obtained by DRE provides comparable results to samples obtained by patients. This creates potential benefit in speed and ease of testing for patients. However, not all DRE sampling attempts are successful, and the clinician must be satisfied that enough faeces is obtained to wipe adequately into all grooves.


Assuntos
Neoplasias Colorretais , Humanos , Neoplasias Colorretais/diagnóstico , Exame Retal Digital , Estudos Prospectivos , Hemoglobinas/análise , Sangue Oculto , Fezes/química , Sensibilidade e Especificidade , Detecção Precoce de Câncer/métodos
12.
Eur J Neurol ; 30(3): 729-740, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36409153

RESUMO

BACKGROUND AND PURPOSE: This study evaluates the quantitative measurability of glial fibrillary acidic protein (GFAP), neurofilament light chain (NfL), ubiquitin carboxy-terminal hydrolase L1 (UCH-L1) and total tau (t-tau) in urine of patients with acute cerebral damage. METHODS: Serum and urine samples were prospectively collected from patients with an acute ischemic stroke or intracerebral hemorrhage (target group) and compared to healthy subjects (control group); samples were measured using ultrasensitive single-molecule arrays (Simoa®). Glomerular barrier function was assessed based on albumin-creatinine ratio (ACR); biomarker-creatinine ratios were calculated for correction of urine dilution. RESULTS: Ninety-three urine-serum pairs in the target group and 10 urine-serum pairs in the control group were measured. The mean absolute concentration ± standard deviation in urine of the target and control groups were 184.7 ± 362.4 pg/ml and 27.3 ± 24.1 pg/ml for GFAP (r = 0.3 [Wilcoxon effect size], p = 0.007), 17.5 ± 38.6 pg/ml and 0.9 ± 0.3 pg/ml for NfL (r = 0.4, p < 0.005), 320.2 ± 443.3 pg/ml and 109.6 ± 116.8 pg/ml for UCH-L1 (r = 0.26, p = 0.014), and 219.5 ± 255.8 pg/ml and 21.1 ± 27.1 pg/ml for t-tau (r = 0.37, p < 0.005), respectively, whereas biomarker-creatinine ratio was significantly different only for NfL (r = 0.29, p = 0.015) and t-tau (r = 0.32, p < 0.01). In patients with intact glomerular barrier (ACR < 30 mg/g), only NfL in urine was significantly different between the target and control group and showed a significant correlation with the respective serum concentrations (r = 0.58 [Pearson's correlation-coefficient], p < 0.005). CONCLUSION: All four investigated biomarkers could be measured in urine, with NfL and t-tau showing the strongest effect size after correction for urine dilution. NfL revealed the most accurate relation between serum and urine concentrations in patients with intact kidney function.


Assuntos
AVC Isquêmico , Humanos , Creatinina , Encéfalo/metabolismo , Neurônios , Biomarcadores , Proteína Glial Fibrilar Ácida , Proteínas de Neurofilamentos
13.
Clin Chem Lab Med ; 61(2): 302-310, 2023 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-36395058

RESUMO

OBJECTIVES: During 2020, the UK's Department of Health and Social Care (DHSC) established the Moonshot programme to fund various diagnostic approaches for the detection of SARS-CoV-2, the pathogen behind the COVID-19 pandemic. Mass spectrometry was one of the technologies proposed to increase testing capacity. METHODS: Moonshot funded a multi-phase development programme, bringing together experts from academia, industry and the NHS to develop a state-of-the-art targeted protein assay utilising enrichment and liquid chromatography tandem mass spectrometry (LC-MS/MS) to capture and detect low levels of tryptic peptides derived from SARS-CoV-2 virus. The assay relies on detection of target peptides, ADETQALPQRK (ADE) and AYNVTQAFGR (AYN), derived from the nucleocapsid protein of SARS-CoV-2, measurement of which allowed the specific, sensitive, and robust detection of the virus from nasopharyngeal (NP) swabs. The diagnostic sensitivity and specificity of LC-MS/MS was compared with reverse transcription quantitative real-time polymerase chain reaction (RT-qPCR) via a prospective study. RESULTS: Analysis of NP swabs (n=361) with a median RT-qPCR quantification cycle (Cq) of 27 (range 16.7-39.1) demonstrated diagnostic sensitivity of 92.4% (87.4-95.5), specificity of 97.4% (94.0-98.9) and near total concordance with RT-qPCR (Cohen's Kappa 0.90). Excluding Cq>32 samples, sensitivity was 97.9% (94.1-99.3), specificity 97.4% (94.0-98.9) and Cohen's Kappa 0.95. CONCLUSIONS: This unique collaboration between academia, industry and the NHS enabled development, translation, and validation of a SARS-CoV-2 method in NP swabs to be achieved in 5 months. This pilot provides a model and pipeline for future accelerated development and implementation of LC-MS/MS protein/peptide assays into the routine clinical laboratory.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Pandemias , COVID-19/diagnóstico , Teste para COVID-19 , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida , Estudos Prospectivos , Técnicas de Laboratório Clínico/métodos , Sensibilidade e Especificidade , Peptídeos
14.
Ann Clin Biochem ; 60(2): 92-99, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36348502

RESUMO

BACKGROUND: The widely accepted practice of not reporting any results from ethylenediaminetetraacetic acid (EDTA) contaminated samples necessitates repeat phlebotomy and could delay clinical management decisions. EDTA, however, interferes variably or not at all in assays. EDTA concentration in contaminated samples, like serum indices, therefore, could be used to selectively report the result of analytes not affected at measured EDTA concentration. METHODS: A serum pool, level 1 and level 3 internal quality control materials were spiked with tripotassium-EDTA to create samples with EDTA concentration up to 6.0 mmol/L. EDTA and 45 common and critically important analytes were measured on Abbott Architect to identify EDTA concentrations for analytes where the change in concentration exceeded their respective reference change value (RCV) for unidirectional change at 95% probability. RESULTS: Serum potassium increased and calcium decreased exceeding RCV at 0.17 mmol/L EDTA. Alkaline phosphatase (ALP) decreased exceeding RCV at EDTA >1.86 mmol/L. The decrease in iron did not exceed a wide RCV of 61.9% until maximum spiked EDTA but exceeded the desirable specification for allowable total error (30.7%) at EDTA >1.86 mmol/L. The small decrease in magnesium did not exceed RCV. EDTA up to the concentration in blood collection tubes did not affect the results of any other measured analyte. CONCLUSIONS: Only serum potassium, calcium, ALP and iron studies, of the 45 analytes studied, should not be reported in EDTA contaminated samples. EDTA concentration cut-offs for selective reporting would further facilitate reporting of these analytes in EDTA contaminated samples.


Assuntos
Coleta de Amostras Sanguíneas , Cálcio , Humanos , Ácido Edético , Coleta de Amostras Sanguíneas/métodos , Potássio , Fosfatase Alcalina , Ferro
15.
Front Cardiovasc Med ; 9: 998687, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36337867

RESUMO

Introduction: To perform Calibrated Automated Thrombography (CAT), the use of reduced plasma volumes (referred to as "MidiCAT") makes it possible to more efficiently use limited volumes of valuable biobanked plasma samples and decreases expenses for reagents. It is, however, unclear whether the MidiCAT procedure is suitable when thrombin generation (TG) is studied in the presence of added thrombomodulin (TG-TM). Moreover, a simplified centrifugation scheme would facilitate biobanking, if appropriate, for more sensitive coagulation studies. We aimed to compare the results of "MidiCAT" (halved plasma and reagent volumes) with those from regular CAT, in the absence or presence of TM, as well as to study the impact of a single-centrifugation scheme for plasma preparation before freezing. Materials and methods: Plasma samples were prepared from the citrated blood from 20 Geneva hospital diverse patients without gross coagulation abnormalities with a single- or double-centrifugation scheme. Samples were kept frozen at -80°C and thawed just before the TG assay in duplicate under two conditions: 1 pM tissue factor (TF) or 5 pM TF + TM. Results and discussion: (1) We externally validated "MidiCAT" and also extended the validation to TG-TM. Whatever the method (CAT or MidiCAT), intra-assay (assessed with duplicates) CV was below 6% (1 pM TF) or below 10% (5 pM TF + TM) for ETP. Agreement between the MidiCAT and CAT results was satisfactory; the p coefficients were above 0.95 for ETP and above 0.90 for most other parameters; biases for ETP were +10.0% (1 pM FT) and +13.5% (5 pM + TM). (2) The centrifugation scheme markedly affected the results obtained in the presence of TM, whereas the bias and limit of agreement (difference plots) were low for the no TM condition. The bias in the presence of TM was obvious, more marked with plasma samples sensitive to TM when double centrifuged: the lower the ETP-TM, the greater the relative difference between the ETP-TM of plasma samples prepared with just single centrifugation and the reference plasma samples. Thus, a single-centrifugation procedure, as is often used for plasma biobanking, is suitable for TG study only if it is not performed in the presence of TM.

16.
J Pathol Inform ; 13: 100128, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36268063

RESUMO

Introduction: Serum protein electrophoresis (SPEP) is commonly used to detect monoclonal paraproteins to meet laboratory diagnostic criteria for plasma cell neoplasms. We propose an automated screening method for paraprotein detection that uses minimal computational resources for training and deployment. Methods: A model screening for paraproteins based on the presence of high-frequency components in the spatial frequency spectrum of the SPEP densitometry curve was calibrated on a set of 330 samples, and evaluated on representative (n=110) and external (n=1,321) test sets. The model takes as input a patient's serum densitometry curve and a standardized control curve and outputs a prediction of whether a paraprotein is present. We built an interactive web application allowing users to easily perform paraprotein screening given inputs for densitometry curves, as well as a macro-enabled spreadsheet for easy automated screening. Results: When tuned to maximize likelihood ratio with minimum sensitivity 0.90, the model achieved AUC 0.90, sensitivity 0.90, positive-predictive value 0.64, specificity 0.55, and accuracy 0.72 in the representative test set. In the external test set, the model achieved AUC 0.90, sensitivity 0.97, positive-predictive value 0.42, specificity 0.29, and accuracy 0.52. A subset analysis showed sensitivities of 0.90, 0.96, and 1.0 in detecting low (0.1-0.5 g/dL), medium (0.5-3.0 g/dL), and high paraprotein levels (≥3.0 g/dL), respectively. We have released a web service allowing users to score their own SPEP data, and also released the algorithm and application programming interface in an open-source package allowing users to customize the model to their needs. Conclusions: We developed a proof of concept for an automated method for paraprotein screening using only the characteristics of the SPEP curve. Future work should focus on testing the method with other laboratory data including immunofixation gels, as well as incorporation of outside data sources including clinical data.

17.
Clin Chem ; 68(11): 1410-1424, 2022 11 03.
Artigo em Inglês | MEDLINE | ID: mdl-36264679

RESUMO

BACKGROUND: Indirect methods leverage real-world data for the estimation of reference intervals. These constitute an active field of research, and several methods have been developed recently. So far, no standardized tool for evaluation and comparison of indirect methods exists. METHODS: We provide RIbench, a benchmarking suite for quantitative evaluation of any existing or novel indirect method. The benchmark contains simulated test sets for 10 biomarkers mimicking routine measurements of a mixed distribution of non-pathological (reference) values and pathological values. The non-pathological distributions represent 4 common distribution types: normal, skewed, heavily skewed, and skewed-and-shifted. To identify strengths and weaknesses of indirect methods, test sets have varying sample sizes and pathological distributions differ in location, extent of overlap, and fraction. For performance evaluation, we use an overall benchmark score and sub-scores derived from absolute z-score deviations between estimated and true reference limits. We illustrate the application of RIbench by evaluating and comparing the Hoffmann method and 4 modern indirect methods -TML (Truncated-Maximum-Likelihood), kosmic, TMC (Truncated-Minimum-Chi-Square), and refineR- against one another and against a nonparametric direct method (n = 120). RESULTS: For the modern indirect methods, pathological fraction and sample size had a strong influence on the results: With a pathological fraction up to 20% and a minimum sample size of 5000, most methods achieved results comparable or superior to the direct method. CONCLUSIONS: We present RIbench, an open-source R-package, for the systematic evaluation of existing and novel indirect methods. RIbench can serve as a tool for enhancement of indirect methods, improving the estimation of reference intervals.


Assuntos
Benchmarking , Humanos , Valores de Referência , Tamanho da Amostra
18.
J Clin Med ; 11(19)2022 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-36233689

RESUMO

Diagnosis of tuberculosis, and especially the diagnosis of extrapulmonary tuberculosis, still faces challenges in clinical practice. There are several reasons for this. Methods based on the detection of Mycobacterium tuberculosis (Mtb) are insufficiently sensitive, methods based on the detection of Mtb-specific immune responses cannot always differentiate active disease from latent infection, and some of the serological markers of infection with Mtb are insufficiently specific to differentiate tuberculosis from other inflammatory diseases. New tools based on technologies such as flow cytometry, mass spectrometry, high-throughput sequencing, and artificial intelligence have the potential to solve this dilemma. The aim of this review was to provide an updated overview of current efforts to optimize classical diagnostic methods, as well as new molecular and other methodologies, for accurate diagnosis of patients with Mtb infection.

19.
Rev. cuba. endocrinol ; 33(2)ago. 2022.
Artigo em Espanhol | CUMED, LILACS | ID: biblio-1441545

RESUMO

Introducción: El síndrome de ovario poliquístico es el trastorno endocrino más frecuente en la mujer durante la etapa reproductiva. Se han realizado varios consensos con el fin de definir sus criterios diagnósticos y el hiperandrogenismo siempre ha estado presente dentro, ya sea tipo clínico o humoral. Objetivo: Describir los aspectos relacionados con el diagnostico hormonal en el síndrome de ovario poliquístico. Métodos: Se realizó una revisión bibliográfica sobre aspectos relacionados con el diagnóstico hormonal del síndrome de ovario poliquístico. Se obtuvieron artículos originales en inglés de las bases Pubmed, Google académico, EMBASE y MEDLINE. Se priorizó el término que aparece en el MESH BROWSER de síndrome de ovario poliquístico. Conclusiones: El diagnostico hormonal del síndrome de ovario poliquístico debe demostrar el hiperandrogenismo de manera bioquímica, siempre que sea posible, aunque si existe evidencia clínica basada en los propios criterios diagnósticos no es obligatorio. El método de laboratorio más útil al parecer es la determinación de la testosterona libre o en su lugar el del índice de andrógenos libres, seguido de la testosterona total. Otras determinaciones de andrógenos tienen menos valor como primera línea(AU)


Introduction: Polycystic ovary syndrome is the most common endocrine disorder in women during the reproductive stage. Several consensuses have been made in order to define its diagnostic criteria and hyperandrogenism has always been present, either clinical or mood related. Objective: To describe the aspects related to hormonal diagnosis in polycystic ovary syndrome. Methods: A literature review was performed on aspects related to the hormonal diagnosis of polycystic ovary syndrome. Original articles in English were obtained from Pubmed, Google Scholar, EMBASE and MEDLINE databases. Priority was given to the MESH BROWSER term polycystic ovary syndrome. Results: The hormonal diagnosis of polycystic ovary syndrome should demonstrate hyperandrogenism biochemically, whenever possible, although if there is clinical evidence based on the diagnostic criteria themselves it is not mandatory. The most useful laboratory method appears to be the determination of free testosterone or instead that of the free androgen index, followed by total testosterone. Other androgen determinations are of less value as first line(AU)


Assuntos
Humanos , Feminino , Adulto , Síndrome do Ovário Policístico/diagnóstico , Literatura de Revisão como Assunto , Bases de Dados Bibliográficas
20.
Clin Chem ; 68(8): 1075-1083, 2022 07 27.
Artigo em Inglês | MEDLINE | ID: mdl-35699503

RESUMO

BACKGROUND: Newborn screening (NBS) laboratories in the United Kingdom adhere to common protocols based on single analyte cutoff values (COVs); therefore, interlaboratory harmonization is of paramount importance. Interlaboratory variation for screening analytes in UK NBS laboratories ranges from 17% to 59%. While using common stable isotope internal standards has been shown to significantly reduce interlaboratory variation, instrument set-up, sample extraction, and calibration approach are also key factors. METHODS: Dried blood spot (DBS) extraction processes, instrument set-up, mobile-phase composition, sample introduction technique, and calibration approach of flow injection analysis-tandem mass spectrometry (FIA-MS/MS) methods were optimized. Inter- and intralaboratory variation of methionine, leucine, phenylalanine, tyrosine, isovaleryl-carnitine, glutaryl-carnitine, octanoyl-carnitine, and decanoyl-carnitine were determined pre- and postoptimization, using 3 different calibration approaches. RESULTS: Optimal recovery of analytes from DBS was achieved with a 35-min extraction time and 80% methanol (150 µL). Optimized methodology decreased the mean intralaboratory percentage relative SD (%RSD) for the 8 analytes from 20.7% (range 4.1-46.0) to 5.4% (range 3.0-8.5). The alternative calibration approach reduced the mean interlaboratory %RSD for all analytes from 16.8% (range 4.1-25.0) to 7.1% (range 4.1-11.0). Nuclear magnetic resonance analysis of the calibration material highlighted the need for standardization. The purities of isovaleryl-carnitine and glutaryl-carnitine were 85.13% and 69.94% respectively, below the manufacturer's stated values of ≥98%. CONCLUSIONS: For NBS programs provided by multiple laboratories using single analyte COVs, harmonization and standardization of results can be achieved by optimizing legacy FIA-MS/MS methods, adopting a common analytical protocol, and using standardized calibration material rather than internal calibration.


Assuntos
Análise de Injeção de Fluxo , Espectrometria de Massas em Tandem , Calibragem , Carnitina , Análise de Injeção de Fluxo/métodos , Humanos , Recém-Nascido , Triagem Neonatal/métodos , Padrões de Referência , Espectrometria de Massas em Tandem/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...