Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 933
Filtrar
1.
J Anesth ; 2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-38909122

RESUMO

The use of the laryngeal mask airway (LMA), which offers the benefits of ease in insertion and prevention of tracheal damage, is associated with a risk of flow leakage. This study analyzed our extensive database to compare leakage associated with the use of LMA and endotracheal tube (ETT). Adult patients who underwent chest wall, abdominal wall, inguinal region, limb, transurethral, or transvaginal surgery and received either LMA or ETT between January 2007 and March 2020 were included. The leak fraction was calculated as (inspiratory tidal volume-expiratory tidal volume)/(inspiratory tidal volume) × 100% every minute during intraoperative stable positive pressure ventilation. The median leak fraction was calculated for each case. The leak fraction in the LMA group demonstrated a left-skewed distribution with a larger proportion of excessive leak fraction. The leak fraction in the LMA group (median, 7.9%; interquartile range, 4.8-11.4%) was significantly lower than that in the ETT group (median, 9.1%; interquartile range: 5.5-12.4%; P < 0.001). This tendency was consistent across subgroups divided by sex, age, type of surgery, and ventilation mode. We propose that LMA provides leakage comparable to or less than ETT in most cases if stable positive pressure ventilation is achieved.

2.
J Otolaryngol Head Neck Surg ; 53: 19160216241263851, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38899617

RESUMO

BACKGROUND: Adenotonsillectomy is one of the most common surgical procedures worldwide. The current standard for securing the airway in patients undergoing adenotonsillectomy is endotracheal tube (ETT) intubation. Several studies have investigated the use of the laryngeal mask airway (LMA) in this procedure. We conducted a systematic review and meta-analysis to compare the safety and efficacy of the LMA versus ETT in adenotonsillectomy. METHOD: Databases were searched from inception to 2022 for randomized controlled trials and comparative studies. Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were followed. The primary outcome is the rate of perioperative respiratory adverse events (PRAEs). Secondary outcomes included the rate of conversion to ETT, desaturations, nausea/vomiting, and surgical time. A subgroup analysis, risk of bias, publication bias, and Grading of Recommendations Assessment, Development, and Evaluation (GRADE) assessments were also performed. RESULTS: Twelve studies were included in the analysis (4176 patients). The mean overall conversion to ETT was 8.36% [95% confidence interval (CI) = 8.17, 8.54], and for the pediatric group 8.27% (95% CI = 8.08, 8.47). The mean rate of conversion to ETT secondary to complications was 2.89% (95% CI = 2.76, 3.03) while the rest was from poor surgical access. Overall, there was no significant difference in PRAEs [odds ratio (OR) 1.16, 95% CI = 0.60, 2.22], desaturations (OR 0.79, 95% CI = 0.38, 1.64), or minor complications (OR 0.89, 95% CI = 0.50, 1.55). The use of LMA yielded significantly shorter operative time (mean difference -4.38 minutes, 95% CI = -8.28, -0.49) and emergence time (mean difference -4.15 minutes, 95% CI = -5.63, -2.67). CONCLUSION: For adenotonsillectomy surgery, LMA is a safe alternative to ETT and requires less operative time. Careful patient selection and judgment of the surgeon and anesthesiologist are necessary, especially given the 8% conversion to ETT rate.


Assuntos
Adenoidectomia , Máscaras Laríngeas , Tonsilectomia , Humanos , Tonsilectomia/efeitos adversos , Tonsilectomia/métodos , Adenoidectomia/efeitos adversos , Adenoidectomia/métodos , Máscaras Laríngeas/efeitos adversos , Intubação Intratraqueal , Complicações Pós-Operatórias/epidemiologia
3.
J Cardiothorac Surg ; 19(1): 361, 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38915035

RESUMO

BACKGROUND: Endotracheal intubation is often associated with postoperative complications such as sore throat discomfort and hoarseness, reducing patient satisfaction and prolonging hospital stays. Laryngeal mask airway (LMA) plays a critical role in reducing airway complications related to endotracheal intubation. This meta-analysis was performed to determine the efficacy and safety of LMA in video-assisted thoracic surgery (VATS). METHODS: The PubMed, Embase, Cochrane Library, Medline and Web of Science databases were searched for eligible studies from inception until October 5, 2023. Cochrane's tool (RoB 2) was used to evaluate the possibility biases of RCTs. We performed sensitivity analysis and subgroup analysis to assess the robustness of the results. RESULTS: Seven articles were included in this meta-analysis. Compared with endotracheal intubation, there was no significant difference in the postoperative hospital stay (SMD = -0.47, 95% CI = -0.98-0.03, P = 0.06), intraoperative minimum SpO2 (SMD = 0.00, 95% CI = -0.49-0.49, P = 1.00), hypoxemia (RR = 1.00, 95% CI = 0.26-3.89, P = 1.00), intraoperative highest PetCO2 (SMD = 0.51, 95% CI = -0.12-1.15, P = 0.11), surgical field satisfaction (RR = 1.01, 95% CI = 0.98-1.03, P = 0.61), anesthesia time (SMD = -0.10, 95% CI = -0.30-0.10, P = 0.31), operation time (SMD = 0.06, 95% CI = -0.13-0.24, P = 0.55) and blood loss (SMD =- 0.13, 95% CI = -0.33-0.07, P = 0.21) in LMA group. However, LMA was associated with a lower incidence of throat discomfort (RR = 0.28, 95% CI = 0.17-0.48, P < 0.00001) and postoperative hoarseness (RR = 0.36, 95% CI = 0.16-0.81, P = 0.01), endotracheal intubation was found in connection with a longer postoperative awake time (SMD = -2.19, 95% CI = -3.49 - -0.89, P = 0.001). CONCLUSION: Compared with endotracheal intubation, LMA can effectively reduce the incidence of throat discomfort and hoarseness post-VATS, and can accelerate the recovery from anesthesia. LMA appears to be an alternative to endotracheal intubation for some specific thoracic surgical procedures, and the efficacy and safety of LMA in VATS need to be further explored in the future.


Assuntos
Intubação Intratraqueal , Máscaras Laríngeas , Ensaios Clínicos Controlados Aleatórios como Assunto , Cirurgia Torácica Vídeoassistida , Humanos , Máscaras Laríngeas/efeitos adversos , Cirurgia Torácica Vídeoassistida/métodos , Intubação Intratraqueal/métodos , Intubação Intratraqueal/efeitos adversos , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/epidemiologia , Tempo de Internação
4.
Indian J Thorac Cardiovasc Surg ; 40(4): 473-475, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38919200

RESUMO

Tracheobronchial foreign body (TFB) aspiration is an uncommon but potentially life-threatening event. This case report discusses the successful extraction of a metallic screw aspirated by a 48-year-old woman with intellectual disability, using flexible bronchoscopy through the i-gel® laryngeal mask under general anesthesia. The i-gel® device proved effective in maintaining airway access and facilitating bronchoscopy, emphasizing its utility in challenging cases. The report underscores the significance of careful assessment, skillful intervention, and multidisciplinary teamwork in managing TFB aspirations, especially in uncooperative patients with comorbidities.

5.
Neonatology ; : 1-11, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38834044

RESUMO

INTRODUCTION: Laryngeal mask airway (LMA) use in neonatal resuscitation is limited despite existing evidence and recommendations. This survey investigated the knowledge and experience of healthcare providers on the use of the LMA and explored barriers and solutions for implementation. METHODS: This online, cross-sectional survey on LMA in neonatal resuscitation involved healthcare professionals of the Union of European Neonatal and Perinatal Societies (UENPS). RESULTS: A total of 858 healthcare professionals from 42 countries participated in the survey. Only 6% took part in an LMA-specific course. Some delivery rooms were not equipped with LMA (26.1%). LMA was mainly considered after the failure of a face mask (FM) or endotracheal tube (ET), while the first choice was limited to neonates with upper airway malformations. LMA and FM were considered easier to position but less effective than ET, while LMA was considered less invasive than ET but more invasive than FM. Participants felt less competent and experienced with LMA than FM and ET. The lack of confidence in LMA was perceived as the main barrier to its implementation in neonatal resuscitation. More training, supervision, and device availability in delivery wards were suggested as possible actions to overcome those barriers. CONCLUSION: Our survey confirms previous findings on limited knowledge, experience, and confidence with LMA, which is usually considered an option after the failure of FM/ET. Our findings highlight the need for increasing the availability of LMA in delivery wards. Moreover, increasing LMA training and having an LMA expert supervisor during clinical practice may improve the implementation of LMA use in neonatal clinical practice.

6.
Cureus ; 16(5): e59543, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38832207

RESUMO

Subglottic stenosis (SGS) can be asymptomatic in cases with slow-growing granulomas. In this study, we report a case of SGS discovered during tracheal intubation for anesthesia induction. A 74-year-old woman was scheduled for surgery under general anesthesia for a left humeral fracture. Resistance was observed when the tracheal tube passed through the glottis, stopping the tube from advancing. We placed a laryngeal mask (LMA) to secure her airway and examined it using a bronchial fiber to detect circumferential stenosis of the subglottis due to granulation. The airway was secured using an LMA instead of intubation, and the patient was successfully managed under anesthesia. Asymptomatic SGS is difficult to detect preoperatively, and anesthesiologists may encounter unexpected intubation issues. LMA is an important tool for an effective strategy to manage intubation difficulties.

8.
Heliyon ; 10(9): e30511, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38765139

RESUMO

Objective: To prospectively determine the median effective dose (ED50) of propofol for inhibiting a response to laryngeal mask airway (LMA) insertion when combined with different doses of esketamine in female patients. Methods: A total of 58 female patients (aged 20-60 years, ASAⅠ-Ⅱ) scheduled for elective hysteroscopy were enrolled and randomly divided into 2 groups, one of which was administered 0.2 mg/kg of esketamine (K1 group, n = 28) and the other 0.3 mg/kg of esketamine (K2 group, n = 30). The 2 groups received the corresponding doses of esketamine intravenously, followed by an intravenous injection of propofol (injection time was 30 s). The initial dose of propofol was 2 mg/kg, and the dose ratio of propofol in the adjacent patients was 0.9. If a positive reaction occurred due to LMA insertion, the dose ratio in the next patient was increased by 1 gradient; if not, the dose ratio was decreased by 1 gradient. The ED50, 95 % effective dose (ED95) and 95 % confidence interval (CI) of propofol for inhibiting a response to LMA insertion in the 2 esketamine groups were calculated using probit analysis. Results: The ED50 of propofol for inhibiting a response to LMA insertion in female patients was 1.95 mg/kg (95 % CI, 1.82-2.08 mg/kg) in the K1 group and 1.60 mg/kg (95 % CI, 1.18-1.83 mg/kg) in the K2 group. The ED95 of propofol for inhibiting a response to LMA insertion in female patients was 2.22 mg/kg (95 % CI, 2.09-2.86 mg/kg) in the K1 group and 2.15 mg/kg (95 % CI, 1.88-3.09 mg/kg) in the K2 group. Conclusion: Propofol combined with 0.3 mg/kg of esketamine has low ED50 and ED95 effective doses for inhibiting an LMA insertion response in female patients undergoing hysteroscopy and surgery. There were no significant adverse effects, but the additional dose of propofol and airway pressure were significantly higher than those in the group administered 0.2 mg/kg of esketamine. Based on the results, we recommend the combination of propofol with 0.2 mg/kg esketamine for optimal conditions during LMA insertion in women undergoing hysteroscopy.

9.
Turk J Emerg Med ; 24(2): 97-102, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38766418

RESUMO

OBJECTIVES: Supraglottic airway (SGA) devices are good alternatives for failed intubations or difficult airways. The aim of our study was to compare the success of intubation with SGA devices such as LMA Fastrach® (LMA Fastrach), Ambu Aura-i® (Aura-i), and Cookgas Air-Q® (Air-Q) in an airway manikin by novice practitioners. METHODS: This study was conducted in a randomized crossover design using a manikin model. Following training on the equipment used, 36 6th-year medical students were randomized into six groups. Participants performed three stages of intubation as follows: the first stage (1S) as SGA insertion, the second stage (2S) as intubation through the SGA, and the third stage (3S) as the removal of the SGA over the intubation tube. The primary outcomes were intubation success and duration. RESULTS: The successful intubation rate (Stage 1S + 2S + 3S) was 100% for LMA Fastrach and Air-Q and 83.3% for Aura-i (P = 0.002). The median time to intubation was 54.4 s, 55.8 s, and 58.7 s for LMA Fastrach, Aura-i, and Air-Q, respectively (P = 0.794). CONCLUSION: Our study shows that novice practitioners can proficiently utilize LMA Fastrach, Air-Q, and Aura-i as SGAs in airway management. LMA Fastrach and Air-Q are more successful for endotracheal intubation than Aura-i. While the successful intubation time with SGA is similar for all three devices, the successful SGA insertion time is shorter with LMA Fastrach and Aura-i compared to Air-Q. Practitioners preferred LMA Fastrach and Air-Q more than Aura-i.

10.
Anaesthesiol Intensive Ther ; 56(1): 47-53, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38741443

RESUMO

INTRODUCTION: Laryngeal mask airway-blockbuster (LMA-BT) is a relatively new supraglottic airway device (SGAD). In this study, we compared LMA-BT with I-Gel LMA for efficacy of blind tracheal intubation. MATERIAL AND METHODS: We conducted a single-blind prospective study after ethical approval. One hundred American Society of Anesthesiology (ASA) Grade I-III (age 18-60 years) patients scheduled for elective surgery under general anaesthesia with endotracheal intubation were included and randomly divided into 2 groups. Blind tracheal intubation was performed through LMA-BT ( n = 50) and I-Gel ( n = 50) in groups 1 and 2, respectively. The primary aim was to evaluate the first pass success rate of blind tracheal intubation through the LMAs. The secondary objectives noted were attempts and ease of LMA insertion, total time taken for LMA insertion, airway seal pressure of LMA, ease of NGT insertion through LMA, fibre-optic grading of laryngeal view through LMA, overall success rate and time of intubation through LMA, time for LMA removal, and complications, if any. RESULTS: In the LMA-BT group, the first pass success rate ( P < 0.019) and the overall success rate of intubation ( P < 0.005) were significantly higher than in the I-Gel group. Using LMA-BT also resulted in statistically significant shorter intubation time ( P < 0.0001) with higher airway seal pressure as compared to I-Gel ( P < 0.001). The difference in the first attempt insertion, number of insertion attempts, ease and time of LMA insertion and removal after intubation, and postoperative complications were comparable among the groups. CONCLUSIONS: LMA-BT is a superior device as compared to I-Gel LMA as a conduit for blind tracheal intubation.


Assuntos
Anestesia Geral , Intubação Intratraqueal , Máscaras Laríngeas , Humanos , Intubação Intratraqueal/métodos , Intubação Intratraqueal/instrumentação , Método Simples-Cego , Adulto , Estudos Prospectivos , Feminino , Masculino , Pessoa de Meia-Idade , Anestesia Geral/métodos , Adulto Jovem , Adolescente
11.
Artigo em Inglês | MEDLINE | ID: mdl-38797374

RESUMO

The Airway section of the Spanish Society of Anesthesiology, Reanimation and Pain Therapy (SEDAR), Spanish Society of Emergency and Emergency Medicine (SEMES) and Spanish Society of Otolaryngology, Head and Neck Surgery (SEORL-CCC) present the Guidelines for the integral management of difficult airway in adult patients. This document provides recommendations based on current scientific evidence, theoretical-educational tools and implementation tools, mainly cognitive aids, applicable to the treatment of the airway in the field of anesthesiology, critical care, emergencies and prehospital medicine. Its principles are focused on the human factors, cognitive processes for decision-making in critical situations and optimization in the progression of the application of strategies to preserve adequate alveolar oxygenation in order to improve safety and quality of care.

12.
Children (Basel) ; 11(5)2024 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-38790524

RESUMO

Supraglottic airway devices such as laryngeal masks and i-gels are useful for airway management. The i-gel is a relatively new device that replaces the air-inflated cuff of the laryngeal mask with a gel-filled cuff. It remains unclear which device is more effective for neonatal resuscitation. We aimed to evaluate the dependence of successful airway management in neonatal simulators on the device type and providers' backgrounds. Ninety-one healthcare providers performed four attempts at airway management using a laryngeal mask and i-gel in two types of neonatal manikins. The dependence of successful insertions within 16.7 s (75th percentile of all successful insertions) on the device type and providers' specialty, years of healthcare service, and completion of the neonatal resuscitation training course was assessed. Successful insertion (p = 0.001) and insertion time (p = 0.003) were associated with using the i-gel vs. laryngeal mask. The providers' backgrounds were not associated with the outcome. Using the i-gel was associated with more successful airway management than laryngeal masks using neonatal manikins. Considering the limited effect of the provider's specialty and experience, using the i-gel as the first-choice device in neonatal resuscitation may be advantageous. Prospective studies are warranted to compare these devices in the clinical setting.

13.
Bull Emerg Trauma ; 12(1): 1-7, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38689789

RESUMO

Objective: This study aimed to assess and compare the effects of intranasal administration of lidocaine and remifentanil on the condition of LMA insertion and cardiovascular response. Methods: From March 2019 to March 2020, this double-blind randomized clinical trial study was conducted on 60 patients, who underwent general anesthesia with LMA insertion at Faiz Hospital, Isfahan, Iran. After induction of anesthesia and before placing the laryngeal mask, the first group received remifentanil 1 µg/Kg, the second group received lidocaine 2% 1 mg/Kg, and the third group received normal saline with the same volume intranasally. The conditions of LMA insertion and hemodynamic changes that occurred during its insertion were investigated. Results: In terms of demographics characteristics (p>0.05), success in placing the LMA on the first try (p=0.73), number of attempts to insert LMA (p=0.61), performance of LMA (p=0.73), need for additional propofol (p=0.53), frequency of gagging (p=0.53), cough (p=0.15) p), and laryngospasm (p=0.99) did not differ significantly. In the remifentanil group, the cardiovascular response to LMA injection was less than that of the lidocaine group. Moreover, both groups were lower than the saline group, but no significant difference was observed. Conclusion: In facilitating LMA insertion, the effect of intranasal remifentanil was comparable to intranasal lidocaine. Intranasal remifentanil was somewhat more effective than intranasal lidocaine in weakening the cardiovascular response to LMA insertion, but it did not outperform lidocaine.

14.
J Anaesthesiol Clin Pharmacol ; 40(1): 63-68, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38666166

RESUMO

Background and Aims: Several methods are in use for LMA ProSeal™ size selection in pediatric patients. Weight-based method is most commonly used. Pinna size-based method is a promising new technique for accurate size selection. Material and Methods: A total of 146 children aged between 6 months and 12 years undergoing surgery under general surgery were included. They were randomized into either pinna-based group (group X) or weight-based group (group Y). Both groups were compared for accurate placement of ProSeal™ laryngeal mask airway (PLMA), ease of insertion, number of attempts needed, and peak airway pressures. Results: A Comparable number of patients had a Brimacombe score of 3 and above, indicating correct placement in both groups (P = 0.407). PLMA was easily inserted in 79.5% and 87.7% of patients of groups X and Y, respectively (P = 0.180). Insertion was found to be difficult in 20.5% of patients in group X, whereas it was difficult in only 12.3% of patients of group Y (P = 0.180). The two groups were comparable as per the number of attempts needed for insertion (P = 0.161). Mean peak airway pressures too were comparable between both groups. Ease of insertion too, was statistically insignificant between both groups. Conclusions: Pinna size-based estimation of LMA size is an effective alternative method to weight-based selection.

15.
J Anaesthesiol Clin Pharmacol ; 40(1): 75-81, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38666171

RESUMO

Background and Aims: The laryngeal mask airway ProSeal (PLMA) insertion should be easy, fast, and atraumatic. Most studies have been done on adults who cannot be considered as the reflection of pediatric patients. In this study, we compared the first attempt success rate of three techniques of PLMA insertion: introducer, 90° rotation, and pharyngoscopy technique in the pediatric population. Material and Methods: In this prospective comparative randomized study, a total of 135 patients of American Society of Anesthesiology grade I and II, aged three to eleven years, with normal airways scheduled for elective surgery, were randomly allocated into three groups: introducer, 90° rotation, and pharyngoscopy group. Parameters evaluated were: first attempt insertion success rate, insertion time, ease of insertion score, hemodynamic parameters, oropharyngeal seal pressure, manipulations, PLMA blood staining, postoperative sore throat, and hoarseness. Results: First attempt insertion success rate was higher in the 90° rotation (97.78%) and pharyngoscopy (97.78%) group as compared to the introducer group (93.33%). But the result was not statistically significant. PLMA insertion time was the least in the rotation group, followed by the pharyngoscopy and introducer group (P < 0.0001). Mean arterial pressure and heart rate were significantly raised in the pharyngoscopy versus rotation group and the introducer versus 90° rotation group after PLMA insertion. Oropharyngeal seal pressure was significantly higher in the introducer as compared to the rotation group (P = 0.007). Conclusion: All three techniques had a high first-attempt insertion success rate. As the rotation technique had the best result in insertion time and hemodynamic response, it may be considered a good alternative to pharyngoscopy and introducer technique in pediatric patients of age three to eleven years with a normal airway.

16.
Curr Pediatr Rev ; 2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38685776

RESUMO

INTRODUCTION: Current guidelines for neonatal resuscitation suggest the use of a laryngeal mask when ventilation with both facemask and endotracheal tube has failed in newborns weighing >2000 g or delivered ≥ 34 weeks of gestation age. Paediatric I-gel® is one of the latest supraglottic airway management devices suitable for children and newborns. I-gel® use was effective in guaranteeing adequate ventilation in patients with anatomic abnormalities in case of respiratory impairment or during surgical procedures after the induction of anaesthesia. OBJECTIVE: The purpose of our review was to evaluate the use and efficacy of I-gel® in case of complicated intubations. METHODS: In July 2023, two authors of this paper independently conducted searches of the MEDLINE, Web of Science, and Scopus databases without imposing any time constraints or other restrictions. Three case reports were included, each describing the use of I-gel® device in difficult intubations in newborns with anatomical abnormalities. RESULTS: No difficulties were reported in the insertion of the device, which was placed even by inexperienced clinicians. CONCLUSION: The data collected highlighted the possibility of using I-gel® not only as a rescue device after attempted and failed endotracheal placement but also as a first choice in selected patients. Studies on larger cohorts would be needed. Further research involving larger patient cohorts of multicentre NICUs is necessary to confirm the use of laryngeal masks in neonates weighing less than 2000 grams.

17.
Front Pediatr ; 12: 1330737, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38468874

RESUMO

Objective: To investigate the time course of action of different doses of mivacurium and determine the appropriate dose for laryngeal mask airway (LMA) insertion for day-case urologic surgery in children. Methods: A total of 105 patients who enrolled in this study between March 2021 and December 2021 were randomised into 3 groups: Group A (mivacurium 0.15 mg/kg, n = 35), Group B (mivacurium 0.20 mg/kg, n = 35) and Group C (mivacurium 0.25 mg/kg, n = 35). The different doses of mivacurium were injected before LMA insertion. The primary outcomes included the grading of conditions for the LMA insertion-18 score, onset time, recovery index and the duration that mivacurium was effective. Secondary outcomes included pulse oxygen saturation, mean blood pressure, heart rate and the incidence of adverse events. Results: The score of the conditions for LMA insertion in Group A was significantly lower than in Groups C and B (p < 0.005). There was a significant difference in the onset time between Groups B and A (p < 0.005). There was no significant difference in the overall incidence of adverse reactions between these groups (p > 0.05). Conclusion: Anaesthesia with 0.2 mg/kg of mivacurium can effectively shorten the onset time and facilitate insertion of the LMA in children undergoing day-case urologic surgery.

18.
Children (Basel) ; 11(3)2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38539355

RESUMO

Background: The use of laryngeal masks in the surgical treatment of infantile lacrimal duct stenosis is controversial due to the potential risk of aspiration. Aims: This study investigates airway procedures in children aged <6 years for surgery of lacrimal duct stenosis in a tertiary care university hospital. Methods: After institutional approval, airway procedures, duration of anesthesiological measures, and airway-related complications were retrospectively analyzed. Patients were divided into two groups according to the airway procedures used (endotracheal tube [ET] vs. laryngeal mask [LMA] airway). Associations were calculated using the Chi-square test or Mann-Whitney U-test. Results: Clinical data of 84 patients (ET n = 36 [42.9%] vs. LMA n = 48 [57.1%]) were analyzed. There were no significant differences in surgical treatment, age distribution, and pre-existing conditions between the groups. None of the patients showed evidence of tracheal aspiration or changes in measured oxygen saturation. LMA airway shortened time for anesthesia induction (p = 0.006) and time for recovery/emergence period (p = 0.03). In contrast, the time to discharge from the recovery room was significantly prolonged using LMA (p = 0.001). A total of 7 adverse events were recorded. Five of these were directly or indirectly related to ET (laryngo-/bronchospasm; muscle relaxant residual). Conclusions: LMA airway for infantile lacrimal duct stenosis seems to be a safe procedure and should be used in appropriate pediatric patients due to its lower invasiveness, low complication rate, and time savings.

19.
J Pers Med ; 14(3)2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38541053

RESUMO

(1) Background: Supraglottic airway devices (SAD) have been used in children and adolescents undergoing adenotonsillectomies under general anesthesia. This systematic review and meta-analysis investigate the safety and efficacy of using SADs when compared to an endotracheal tube (ETT). (2) Methods: After registering with PROSPERO, databases like PubMed, Scopus, OviD, CINAHL, and Cochrane Library were searched using relevant keywords from the year 2000. We used RoB-2 for risk-of-bias assessment, GRADE for assessing the quality of evidence, RevMan 5.2 for qualitative meta-analysis, and trial sequential analysis (TSA) to corroborate the significant findings of meta-analysis. (3) Results: Out of 200 studies, 5 randomized-controlled trials fulfilled inclusion criteria. The quality of evidence was moderate for laryngospasm, low for airway device failure, and very low for recovery time. The incidence of laryngospasm was comparable between SADs and ETT (RR: 0.80, 95% CI-0.36, 1.80, p = 0.59). The incidence of airway device failure was significantly higher with SADs than ETT (RR: 11.29, 95% CI: 2.73, 46.66, p = 0.0008). The postoperative recovery time was significantly less with SADs than with ETT use (MD: -4.33, 95% CI: -5.28, -3.39, p < 0.0001), which was confirmed by the TSA. (4) Conclusions: The results of this review suggests that use of SADs can provide a lesser postoperative recovery time and comparable incidence of laryngospasm, with a higher incidence of failure of SAD when compared to ETT. Use of SAD for pediatric and adolescent adenotonsillectomies should be individualized based on patient characteristics, and on the expertise of the anesthesiologist and the surgeons involved.

20.
BMC Anesthesiol ; 24(1): 94, 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38454342

RESUMO

BACKGROUND: Remimazolam is a novel ultrashort-acting intravenous benzodiazepine sedative-hypnotic. The combination of remimazolam and sevoflurane does not increase respiratory sensitivity, produce bronchospasm, or cause other adverse conditions. We aimed to observe the effects of different remimazolam doses on the minimum alveolar concentration (MAC) of sevoflurane at end-expiration during laryngeal mask insertion and evaluate the effect of sex on the efficacy of the combination of remimazolam on the suppression of laryngeal mask insertion in adult patients. METHODS: We included 240 patients undergoing laparoscopic surgery under general anesthesia with elective placement of a laryngeal mask (120 males and 120 females). The patients were randomly divided into four groups according to sex: a control group (randomization for female patients, RF0; randomization for male patients, RM0) and three remimazolam groups (RF1, RM1 / RM2, RF2 / RM3, RF3), with 30 patients in each group. Induction was established by vital capacity rapid inhalation induction (VCRII), using 8% sevoflurane and 100% oxygen (6 L/min) in all patients. The (RF1, RM1), (RM2, RF2), and (RM3, RF3) groups were continuously injected with remimazolam at doses of 1, 1.5, and 2.0 mg/kg/h, respectively, while the (RM0, RF0) group was injected with an equal volume of normal saline. The end-expiratory concentration of sevoflurane was adjusted to a preset value after the patient's eyelash reflex disappeared. After the end-expiratory concentration of sevoflurane was kept stable for at least 15 min, the laryngeal mask was placed, and the patient's physical response to the mask placement was observed immediately and within 30 s of placement. The MAC of sevoflurane was measured using the up-and-down sequential method of Dixon. RESULTS: The calculated MAC of end-expiratory sevoflurane during laryngeal mask insertion in adult females was (2.94 ± 0.18)%, (2.69 ± 0.16)%, (2.32 ± 0.16)% and (1.83 ± 0.15)% in groups RF0, RF1, RF2 and RF3; (2.98 ± 0.18)%, (2.80 ± 0.19)%, (2.54 ± 0.15)% and (2.15 ± 0.15)% in male groups RM0, RM1, RM2 and RM3, respectively. The MAC values were significantly lower in the (RF1-RF3, RM1-RM3) group when compared to the (RF0, RM0) group. There was no significant difference between (RF0, RF1) and (RM0, RM1), but the MAC value of the RF2-RF3 group was significantly lower than that of the RM2-RM3 group. CONCLUSIONS: Remimazolam can effectively reduce end-expiratory sevoflurane MAC values during laryngeal mask placement in adults. When remimazolam was measured above 1.5 mg/kg/h, the effect of inhibiting laryngeal mask implantation in female patients was stronger than that in male patients. Remimazolam at a dose of 1-2 mg/kg/h combined with sevoflurane induction can be safely and effectively used in these patients.


Assuntos
Anestésicos Inalatórios , Máscaras Laríngeas , Éteres Metílicos , Adulto , Humanos , Masculino , Feminino , Sevoflurano , Benzodiazepinas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...