Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 671
Filtrar
1.
J Cardiothorac Surg ; 19(1): 361, 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38915035

RESUMO

BACKGROUND: Endotracheal intubation is often associated with postoperative complications such as sore throat discomfort and hoarseness, reducing patient satisfaction and prolonging hospital stays. Laryngeal mask airway (LMA) plays a critical role in reducing airway complications related to endotracheal intubation. This meta-analysis was performed to determine the efficacy and safety of LMA in video-assisted thoracic surgery (VATS). METHODS: The PubMed, Embase, Cochrane Library, Medline and Web of Science databases were searched for eligible studies from inception until October 5, 2023. Cochrane's tool (RoB 2) was used to evaluate the possibility biases of RCTs. We performed sensitivity analysis and subgroup analysis to assess the robustness of the results. RESULTS: Seven articles were included in this meta-analysis. Compared with endotracheal intubation, there was no significant difference in the postoperative hospital stay (SMD = -0.47, 95% CI = -0.98-0.03, P = 0.06), intraoperative minimum SpO2 (SMD = 0.00, 95% CI = -0.49-0.49, P = 1.00), hypoxemia (RR = 1.00, 95% CI = 0.26-3.89, P = 1.00), intraoperative highest PetCO2 (SMD = 0.51, 95% CI = -0.12-1.15, P = 0.11), surgical field satisfaction (RR = 1.01, 95% CI = 0.98-1.03, P = 0.61), anesthesia time (SMD = -0.10, 95% CI = -0.30-0.10, P = 0.31), operation time (SMD = 0.06, 95% CI = -0.13-0.24, P = 0.55) and blood loss (SMD =- 0.13, 95% CI = -0.33-0.07, P = 0.21) in LMA group. However, LMA was associated with a lower incidence of throat discomfort (RR = 0.28, 95% CI = 0.17-0.48, P < 0.00001) and postoperative hoarseness (RR = 0.36, 95% CI = 0.16-0.81, P = 0.01), endotracheal intubation was found in connection with a longer postoperative awake time (SMD = -2.19, 95% CI = -3.49 - -0.89, P = 0.001). CONCLUSION: Compared with endotracheal intubation, LMA can effectively reduce the incidence of throat discomfort and hoarseness post-VATS, and can accelerate the recovery from anesthesia. LMA appears to be an alternative to endotracheal intubation for some specific thoracic surgical procedures, and the efficacy and safety of LMA in VATS need to be further explored in the future.


Assuntos
Intubação Intratraqueal , Máscaras Laríngeas , Ensaios Clínicos Controlados Aleatórios como Assunto , Cirurgia Torácica Vídeoassistida , Humanos , Máscaras Laríngeas/efeitos adversos , Cirurgia Torácica Vídeoassistida/métodos , Intubação Intratraqueal/métodos , Intubação Intratraqueal/efeitos adversos , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/epidemiologia , Tempo de Internação
2.
J Otolaryngol Head Neck Surg ; 53: 19160216241263851, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38899617

RESUMO

BACKGROUND: Adenotonsillectomy is one of the most common surgical procedures worldwide. The current standard for securing the airway in patients undergoing adenotonsillectomy is endotracheal tube (ETT) intubation. Several studies have investigated the use of the laryngeal mask airway (LMA) in this procedure. We conducted a systematic review and meta-analysis to compare the safety and efficacy of the LMA versus ETT in adenotonsillectomy. METHOD: Databases were searched from inception to 2022 for randomized controlled trials and comparative studies. Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were followed. The primary outcome is the rate of perioperative respiratory adverse events (PRAEs). Secondary outcomes included the rate of conversion to ETT, desaturations, nausea/vomiting, and surgical time. A subgroup analysis, risk of bias, publication bias, and Grading of Recommendations Assessment, Development, and Evaluation (GRADE) assessments were also performed. RESULTS: Twelve studies were included in the analysis (4176 patients). The mean overall conversion to ETT was 8.36% [95% confidence interval (CI) = 8.17, 8.54], and for the pediatric group 8.27% (95% CI = 8.08, 8.47). The mean rate of conversion to ETT secondary to complications was 2.89% (95% CI = 2.76, 3.03) while the rest was from poor surgical access. Overall, there was no significant difference in PRAEs [odds ratio (OR) 1.16, 95% CI = 0.60, 2.22], desaturations (OR 0.79, 95% CI = 0.38, 1.64), or minor complications (OR 0.89, 95% CI = 0.50, 1.55). The use of LMA yielded significantly shorter operative time (mean difference -4.38 minutes, 95% CI = -8.28, -0.49) and emergence time (mean difference -4.15 minutes, 95% CI = -5.63, -2.67). CONCLUSION: For adenotonsillectomy surgery, LMA is a safe alternative to ETT and requires less operative time. Careful patient selection and judgment of the surgeon and anesthesiologist are necessary, especially given the 8% conversion to ETT rate.


Assuntos
Adenoidectomia , Máscaras Laríngeas , Tonsilectomia , Humanos , Tonsilectomia/efeitos adversos , Tonsilectomia/métodos , Adenoidectomia/efeitos adversos , Adenoidectomia/métodos , Máscaras Laríngeas/efeitos adversos , Intubação Intratraqueal , Complicações Pós-Operatórias/epidemiologia
3.
Heliyon ; 10(9): e30511, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38765139

RESUMO

Objective: To prospectively determine the median effective dose (ED50) of propofol for inhibiting a response to laryngeal mask airway (LMA) insertion when combined with different doses of esketamine in female patients. Methods: A total of 58 female patients (aged 20-60 years, ASAⅠ-Ⅱ) scheduled for elective hysteroscopy were enrolled and randomly divided into 2 groups, one of which was administered 0.2 mg/kg of esketamine (K1 group, n = 28) and the other 0.3 mg/kg of esketamine (K2 group, n = 30). The 2 groups received the corresponding doses of esketamine intravenously, followed by an intravenous injection of propofol (injection time was 30 s). The initial dose of propofol was 2 mg/kg, and the dose ratio of propofol in the adjacent patients was 0.9. If a positive reaction occurred due to LMA insertion, the dose ratio in the next patient was increased by 1 gradient; if not, the dose ratio was decreased by 1 gradient. The ED50, 95 % effective dose (ED95) and 95 % confidence interval (CI) of propofol for inhibiting a response to LMA insertion in the 2 esketamine groups were calculated using probit analysis. Results: The ED50 of propofol for inhibiting a response to LMA insertion in female patients was 1.95 mg/kg (95 % CI, 1.82-2.08 mg/kg) in the K1 group and 1.60 mg/kg (95 % CI, 1.18-1.83 mg/kg) in the K2 group. The ED95 of propofol for inhibiting a response to LMA insertion in female patients was 2.22 mg/kg (95 % CI, 2.09-2.86 mg/kg) in the K1 group and 2.15 mg/kg (95 % CI, 1.88-3.09 mg/kg) in the K2 group. Conclusion: Propofol combined with 0.3 mg/kg of esketamine has low ED50 and ED95 effective doses for inhibiting an LMA insertion response in female patients undergoing hysteroscopy and surgery. There were no significant adverse effects, but the additional dose of propofol and airway pressure were significantly higher than those in the group administered 0.2 mg/kg of esketamine. Based on the results, we recommend the combination of propofol with 0.2 mg/kg esketamine for optimal conditions during LMA insertion in women undergoing hysteroscopy.

4.
Turk J Emerg Med ; 24(2): 97-102, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38766418

RESUMO

OBJECTIVES: Supraglottic airway (SGA) devices are good alternatives for failed intubations or difficult airways. The aim of our study was to compare the success of intubation with SGA devices such as LMA Fastrach® (LMA Fastrach), Ambu Aura-i® (Aura-i), and Cookgas Air-Q® (Air-Q) in an airway manikin by novice practitioners. METHODS: This study was conducted in a randomized crossover design using a manikin model. Following training on the equipment used, 36 6th-year medical students were randomized into six groups. Participants performed three stages of intubation as follows: the first stage (1S) as SGA insertion, the second stage (2S) as intubation through the SGA, and the third stage (3S) as the removal of the SGA over the intubation tube. The primary outcomes were intubation success and duration. RESULTS: The successful intubation rate (Stage 1S + 2S + 3S) was 100% for LMA Fastrach and Air-Q and 83.3% for Aura-i (P = 0.002). The median time to intubation was 54.4 s, 55.8 s, and 58.7 s for LMA Fastrach, Aura-i, and Air-Q, respectively (P = 0.794). CONCLUSION: Our study shows that novice practitioners can proficiently utilize LMA Fastrach, Air-Q, and Aura-i as SGAs in airway management. LMA Fastrach and Air-Q are more successful for endotracheal intubation than Aura-i. While the successful intubation time with SGA is similar for all three devices, the successful SGA insertion time is shorter with LMA Fastrach and Aura-i compared to Air-Q. Practitioners preferred LMA Fastrach and Air-Q more than Aura-i.

5.
Anaesthesiol Intensive Ther ; 56(1): 47-53, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38741443

RESUMO

INTRODUCTION: Laryngeal mask airway-blockbuster (LMA-BT) is a relatively new supraglottic airway device (SGAD). In this study, we compared LMA-BT with I-Gel LMA for efficacy of blind tracheal intubation. MATERIAL AND METHODS: We conducted a single-blind prospective study after ethical approval. One hundred American Society of Anesthesiology (ASA) Grade I-III (age 18-60 years) patients scheduled for elective surgery under general anaesthesia with endotracheal intubation were included and randomly divided into 2 groups. Blind tracheal intubation was performed through LMA-BT ( n = 50) and I-Gel ( n = 50) in groups 1 and 2, respectively. The primary aim was to evaluate the first pass success rate of blind tracheal intubation through the LMAs. The secondary objectives noted were attempts and ease of LMA insertion, total time taken for LMA insertion, airway seal pressure of LMA, ease of NGT insertion through LMA, fibre-optic grading of laryngeal view through LMA, overall success rate and time of intubation through LMA, time for LMA removal, and complications, if any. RESULTS: In the LMA-BT group, the first pass success rate ( P < 0.019) and the overall success rate of intubation ( P < 0.005) were significantly higher than in the I-Gel group. Using LMA-BT also resulted in statistically significant shorter intubation time ( P < 0.0001) with higher airway seal pressure as compared to I-Gel ( P < 0.001). The difference in the first attempt insertion, number of insertion attempts, ease and time of LMA insertion and removal after intubation, and postoperative complications were comparable among the groups. CONCLUSIONS: LMA-BT is a superior device as compared to I-Gel LMA as a conduit for blind tracheal intubation.


Assuntos
Anestesia Geral , Intubação Intratraqueal , Máscaras Laríngeas , Humanos , Intubação Intratraqueal/métodos , Intubação Intratraqueal/instrumentação , Método Simples-Cego , Adulto , Estudos Prospectivos , Feminino , Masculino , Pessoa de Meia-Idade , Anestesia Geral/métodos , Adulto Jovem , Adolescente
6.
Bull Emerg Trauma ; 12(1): 1-7, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38689789

RESUMO

Objective: This study aimed to assess and compare the effects of intranasal administration of lidocaine and remifentanil on the condition of LMA insertion and cardiovascular response. Methods: From March 2019 to March 2020, this double-blind randomized clinical trial study was conducted on 60 patients, who underwent general anesthesia with LMA insertion at Faiz Hospital, Isfahan, Iran. After induction of anesthesia and before placing the laryngeal mask, the first group received remifentanil 1 µg/Kg, the second group received lidocaine 2% 1 mg/Kg, and the third group received normal saline with the same volume intranasally. The conditions of LMA insertion and hemodynamic changes that occurred during its insertion were investigated. Results: In terms of demographics characteristics (p>0.05), success in placing the LMA on the first try (p=0.73), number of attempts to insert LMA (p=0.61), performance of LMA (p=0.73), need for additional propofol (p=0.53), frequency of gagging (p=0.53), cough (p=0.15) p), and laryngospasm (p=0.99) did not differ significantly. In the remifentanil group, the cardiovascular response to LMA injection was less than that of the lidocaine group. Moreover, both groups were lower than the saline group, but no significant difference was observed. Conclusion: In facilitating LMA insertion, the effect of intranasal remifentanil was comparable to intranasal lidocaine. Intranasal remifentanil was somewhat more effective than intranasal lidocaine in weakening the cardiovascular response to LMA insertion, but it did not outperform lidocaine.

7.
J Anaesthesiol Clin Pharmacol ; 40(1): 63-68, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38666166

RESUMO

Background and Aims: Several methods are in use for LMA ProSeal™ size selection in pediatric patients. Weight-based method is most commonly used. Pinna size-based method is a promising new technique for accurate size selection. Material and Methods: A total of 146 children aged between 6 months and 12 years undergoing surgery under general surgery were included. They were randomized into either pinna-based group (group X) or weight-based group (group Y). Both groups were compared for accurate placement of ProSeal™ laryngeal mask airway (PLMA), ease of insertion, number of attempts needed, and peak airway pressures. Results: A Comparable number of patients had a Brimacombe score of 3 and above, indicating correct placement in both groups (P = 0.407). PLMA was easily inserted in 79.5% and 87.7% of patients of groups X and Y, respectively (P = 0.180). Insertion was found to be difficult in 20.5% of patients in group X, whereas it was difficult in only 12.3% of patients of group Y (P = 0.180). The two groups were comparable as per the number of attempts needed for insertion (P = 0.161). Mean peak airway pressures too were comparable between both groups. Ease of insertion too, was statistically insignificant between both groups. Conclusions: Pinna size-based estimation of LMA size is an effective alternative method to weight-based selection.

8.
J Anaesthesiol Clin Pharmacol ; 40(1): 75-81, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38666171

RESUMO

Background and Aims: The laryngeal mask airway ProSeal (PLMA) insertion should be easy, fast, and atraumatic. Most studies have been done on adults who cannot be considered as the reflection of pediatric patients. In this study, we compared the first attempt success rate of three techniques of PLMA insertion: introducer, 90° rotation, and pharyngoscopy technique in the pediatric population. Material and Methods: In this prospective comparative randomized study, a total of 135 patients of American Society of Anesthesiology grade I and II, aged three to eleven years, with normal airways scheduled for elective surgery, were randomly allocated into three groups: introducer, 90° rotation, and pharyngoscopy group. Parameters evaluated were: first attempt insertion success rate, insertion time, ease of insertion score, hemodynamic parameters, oropharyngeal seal pressure, manipulations, PLMA blood staining, postoperative sore throat, and hoarseness. Results: First attempt insertion success rate was higher in the 90° rotation (97.78%) and pharyngoscopy (97.78%) group as compared to the introducer group (93.33%). But the result was not statistically significant. PLMA insertion time was the least in the rotation group, followed by the pharyngoscopy and introducer group (P < 0.0001). Mean arterial pressure and heart rate were significantly raised in the pharyngoscopy versus rotation group and the introducer versus 90° rotation group after PLMA insertion. Oropharyngeal seal pressure was significantly higher in the introducer as compared to the rotation group (P = 0.007). Conclusion: All three techniques had a high first-attempt insertion success rate. As the rotation technique had the best result in insertion time and hemodynamic response, it may be considered a good alternative to pharyngoscopy and introducer technique in pediatric patients of age three to eleven years with a normal airway.

9.
Front Pediatr ; 12: 1330737, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38468874

RESUMO

Objective: To investigate the time course of action of different doses of mivacurium and determine the appropriate dose for laryngeal mask airway (LMA) insertion for day-case urologic surgery in children. Methods: A total of 105 patients who enrolled in this study between March 2021 and December 2021 were randomised into 3 groups: Group A (mivacurium 0.15 mg/kg, n = 35), Group B (mivacurium 0.20 mg/kg, n = 35) and Group C (mivacurium 0.25 mg/kg, n = 35). The different doses of mivacurium were injected before LMA insertion. The primary outcomes included the grading of conditions for the LMA insertion-18 score, onset time, recovery index and the duration that mivacurium was effective. Secondary outcomes included pulse oxygen saturation, mean blood pressure, heart rate and the incidence of adverse events. Results: The score of the conditions for LMA insertion in Group A was significantly lower than in Groups C and B (p < 0.005). There was a significant difference in the onset time between Groups B and A (p < 0.005). There was no significant difference in the overall incidence of adverse reactions between these groups (p > 0.05). Conclusion: Anaesthesia with 0.2 mg/kg of mivacurium can effectively shorten the onset time and facilitate insertion of the LMA in children undergoing day-case urologic surgery.

10.
BMC Anesthesiol ; 24(1): 94, 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38454342

RESUMO

BACKGROUND: Remimazolam is a novel ultrashort-acting intravenous benzodiazepine sedative-hypnotic. The combination of remimazolam and sevoflurane does not increase respiratory sensitivity, produce bronchospasm, or cause other adverse conditions. We aimed to observe the effects of different remimazolam doses on the minimum alveolar concentration (MAC) of sevoflurane at end-expiration during laryngeal mask insertion and evaluate the effect of sex on the efficacy of the combination of remimazolam on the suppression of laryngeal mask insertion in adult patients. METHODS: We included 240 patients undergoing laparoscopic surgery under general anesthesia with elective placement of a laryngeal mask (120 males and 120 females). The patients were randomly divided into four groups according to sex: a control group (randomization for female patients, RF0; randomization for male patients, RM0) and three remimazolam groups (RF1, RM1 / RM2, RF2 / RM3, RF3), with 30 patients in each group. Induction was established by vital capacity rapid inhalation induction (VCRII), using 8% sevoflurane and 100% oxygen (6 L/min) in all patients. The (RF1, RM1), (RM2, RF2), and (RM3, RF3) groups were continuously injected with remimazolam at doses of 1, 1.5, and 2.0 mg/kg/h, respectively, while the (RM0, RF0) group was injected with an equal volume of normal saline. The end-expiratory concentration of sevoflurane was adjusted to a preset value after the patient's eyelash reflex disappeared. After the end-expiratory concentration of sevoflurane was kept stable for at least 15 min, the laryngeal mask was placed, and the patient's physical response to the mask placement was observed immediately and within 30 s of placement. The MAC of sevoflurane was measured using the up-and-down sequential method of Dixon. RESULTS: The calculated MAC of end-expiratory sevoflurane during laryngeal mask insertion in adult females was (2.94 ± 0.18)%, (2.69 ± 0.16)%, (2.32 ± 0.16)% and (1.83 ± 0.15)% in groups RF0, RF1, RF2 and RF3; (2.98 ± 0.18)%, (2.80 ± 0.19)%, (2.54 ± 0.15)% and (2.15 ± 0.15)% in male groups RM0, RM1, RM2 and RM3, respectively. The MAC values were significantly lower in the (RF1-RF3, RM1-RM3) group when compared to the (RF0, RM0) group. There was no significant difference between (RF0, RF1) and (RM0, RM1), but the MAC value of the RF2-RF3 group was significantly lower than that of the RM2-RM3 group. CONCLUSIONS: Remimazolam can effectively reduce end-expiratory sevoflurane MAC values during laryngeal mask placement in adults. When remimazolam was measured above 1.5 mg/kg/h, the effect of inhibiting laryngeal mask implantation in female patients was stronger than that in male patients. Remimazolam at a dose of 1-2 mg/kg/h combined with sevoflurane induction can be safely and effectively used in these patients.


Assuntos
Anestésicos Inalatórios , Máscaras Laríngeas , Éteres Metílicos , Adulto , Humanos , Masculino , Feminino , Sevoflurano , Benzodiazepinas
11.
Children (Basel) ; 11(3)2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38539355

RESUMO

Background: The use of laryngeal masks in the surgical treatment of infantile lacrimal duct stenosis is controversial due to the potential risk of aspiration. Aims: This study investigates airway procedures in children aged <6 years for surgery of lacrimal duct stenosis in a tertiary care university hospital. Methods: After institutional approval, airway procedures, duration of anesthesiological measures, and airway-related complications were retrospectively analyzed. Patients were divided into two groups according to the airway procedures used (endotracheal tube [ET] vs. laryngeal mask [LMA] airway). Associations were calculated using the Chi-square test or Mann-Whitney U-test. Results: Clinical data of 84 patients (ET n = 36 [42.9%] vs. LMA n = 48 [57.1%]) were analyzed. There were no significant differences in surgical treatment, age distribution, and pre-existing conditions between the groups. None of the patients showed evidence of tracheal aspiration or changes in measured oxygen saturation. LMA airway shortened time for anesthesia induction (p = 0.006) and time for recovery/emergence period (p = 0.03). In contrast, the time to discharge from the recovery room was significantly prolonged using LMA (p = 0.001). A total of 7 adverse events were recorded. Five of these were directly or indirectly related to ET (laryngo-/bronchospasm; muscle relaxant residual). Conclusions: LMA airway for infantile lacrimal duct stenosis seems to be a safe procedure and should be used in appropriate pediatric patients due to its lower invasiveness, low complication rate, and time savings.

12.
J Pers Med ; 14(3)2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38541053

RESUMO

(1) Background: Supraglottic airway devices (SAD) have been used in children and adolescents undergoing adenotonsillectomies under general anesthesia. This systematic review and meta-analysis investigate the safety and efficacy of using SADs when compared to an endotracheal tube (ETT). (2) Methods: After registering with PROSPERO, databases like PubMed, Scopus, OviD, CINAHL, and Cochrane Library were searched using relevant keywords from the year 2000. We used RoB-2 for risk-of-bias assessment, GRADE for assessing the quality of evidence, RevMan 5.2 for qualitative meta-analysis, and trial sequential analysis (TSA) to corroborate the significant findings of meta-analysis. (3) Results: Out of 200 studies, 5 randomized-controlled trials fulfilled inclusion criteria. The quality of evidence was moderate for laryngospasm, low for airway device failure, and very low for recovery time. The incidence of laryngospasm was comparable between SADs and ETT (RR: 0.80, 95% CI-0.36, 1.80, p = 0.59). The incidence of airway device failure was significantly higher with SADs than ETT (RR: 11.29, 95% CI: 2.73, 46.66, p = 0.0008). The postoperative recovery time was significantly less with SADs than with ETT use (MD: -4.33, 95% CI: -5.28, -3.39, p < 0.0001), which was confirmed by the TSA. (4) Conclusions: The results of this review suggests that use of SADs can provide a lesser postoperative recovery time and comparable incidence of laryngospasm, with a higher incidence of failure of SAD when compared to ETT. Use of SAD for pediatric and adolescent adenotonsillectomies should be individualized based on patient characteristics, and on the expertise of the anesthesiologist and the surgeons involved.

13.
Ann Afr Med ; 23(1): 70-75, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38358174

RESUMO

Background The I-LMA ventilates while providing a port for blind insertion of an endotracheal tube. The ILMA Fastrach is used especially for intubating in a difficult airway scenario. Its accompanying endotracheal tube is not economical nor readily available. In comparison, two alternative endotracheal tubes - polyvinyl chloride and wire-reinforced tubes were used for tracheal intubation through the ILMA. AIMS AND OBJECTIVES: The aim of our study was to compare the ease of intubation when using conventional PVC tubes versus the wire-reinforced flexometallic tubes with the ILMA-FastrachTM. The number of attempts, time taken and additional maneuvers were noted. Intra-operative hemodynamic changes, post-operative sore throat, bleeding and hoarseness of voice was recorded over a period of 24 hours. METHODOLOGY: After informed consent, 60 ASA I-II patients undergoing elective surgeries under general anesthesia were allocated to undergo blind intubation with the PVC tube or the wire-reinforced flexometallic tube. RESULTS: More attempts were required for successful intubation using the wire-reinforced tube than the PVC tube with 76.7% passing in the first attempt in the PVC, and 53.3% passing in the first attempt in the flexometallic group. (P = 0.4). Average time for intubation in the PVC group: 28.24 ± 7.22 seconds. Average time for intubation in the flexometallic tube: 45.8 ± 15.78 sec. Occurrence of post-operative sore throat was 13.3% in the PVC group and 26.6% in the flexometallic group, with minimal hoarseness of voice 3.3% in the PVC group and 10% in the flexometallic group. There was also a slightly higher hemodynamic response in those who were intubated with the flexometallic tube than a PVC tube. CONCLUSION: Intubating via the ILMA-Fastrach with the PVC tube offered better intubating conditions with regards to lesser time taken, lesser attempts, less manipulation, and less hemodynamic variations as compared to the patients who were intubated using the wire-reinforced tube.


Résumé Arrière-plan: L'I-LMA ventile tout en fournissant un port pour l'insertion aveugle d'une sonde endotrachéale. L'ILMA Fastrach est utilisé notamment pour l'intubation dans un scénario de voies respiratoires difficiles. La sonde endotrachéale qui l'accompagne n'est ni économique ni facilement disponible. En comparaison, deux tubes endotrachéaux alternatifs ­ du chlorure de polyvinyle et des tubes renforcés de fil ­ ont été utilisés pour l'intubation trachéale via l'ILMA. Buts et objectifs: Le but de notre étude était de comparer la facilité d'intubation lors de l'utilisation de tubes en PVC conventionnels par rapport aux tubes flexométalliques renforcés de fil avec l'ILMA-FastrachTM. Le nombre de tentatives, le temps nécessaire et les manÓuvres supplémentaires ont été notés. Les changements hémodynamiques peropératoires, les maux de gorge postopératoires, les saignements et l'enrouement de la voix ont été enregistrés sur une période de 24 heures. Méthodologie: Après consentement éclairé, 60 patients ASA I-II subissant des interventions chirurgicales électives sous anesthésie générale ont été affectés à une intubation aveugle avec le tube en PVC ou le tube flexométallique renforcé de fil. Résultats: Plus de tentatives ont été nécessaires pour réussir l'intubation à l'aide du tube renforcé par fil métallique qu'avec le tube PVC, avec 76,7 % de réussite lors de la première tentative dans le groupe PVC et 53,3 % de réussite lors de la première tentative dans le groupe flexométallique. (P = 0,4). Temps moyen d'intubation dans le groupe PVC : 28,24 ± 7,22 secondes. Temps moyen d'intubation dans le tube flexométallique : 45,8 ± 15,78 sec. La survenue de maux de gorge postopératoires était de 13,3 % dans le groupe PVC et de 26,6 % dans le groupe flexométallique, avec un enrouement minime de la voix de 3,3 % dans le groupe PVC et de 10 % dans le groupe flexométallique. Il y avait également une réponse hémodynamique légèrement plus élevée chez ceux qui étaient intubés avec le tube flexométallique qu'avec un tube en PVC. Conclusion: L'intubation via l'ILMA-Fastrach avec le tube en PVC offrait de meilleures conditions d'intubation en ce qui concerne moins de temps, moins de tentatives, moins de manipulations et moins de variations hémodynamiques par rapport aux patients intubés à l'aide du tube renforcé de fil Mots-clés: Facilité d'intubation, sonde endotrachéale flexométallique, masque laryngé d'intubation des voies respiratoires, sonde endotrachéale en polychlorure de vinyle.


Assuntos
Máscaras Laríngeas , Faringite , Humanos , Máscaras Laríngeas/efeitos adversos , Cloreto de Polivinila , Rouquidão/etiologia , Intubação Intratraqueal/efeitos adversos , Faringite/etiologia
14.
Artigo em Inglês | MEDLINE | ID: mdl-38225533

RESUMO

BACKGROUND: The current evidence on the use of laryngeal mask airway (LMA) as an airway management technique for general anesthesia (GA) during atrial fibrillation (AF) catheter ablation (CA) is insufficient. This study aims to compare the feasibility, safety, and clinical benefits of LMA and endotracheal intubation (ETI) for airway management in AF CA. METHODS: One hundred fifty-two consecutive patients with AF who underwent CA under GA were included and divided into two groups based on different airway management methods (66 in the LMA group, 86 in the ETI group). After propensity score matching, a final analysis cohort of 132 patients was obtained to compare procedural parameters, adverse events, and prognosis between the two groups. RESULTS: The LMA group exhibited significantly shorter total procedural time (p = 0.039), anesthesia induction time (p = 0.015), and recovery time (p = 0.006) compared to the ETI group. The mean arterial pressure (MAP) and heart rate were significantly lower in the LMA group during extubation and 1-min post-extubation (p < 0.05). Furthermore, the LMA group demonstrated lower MAP levels during intubation (p = 0.029). The incidences of intraoperative hypotension (p = 0.017) and bradycardia (p = 0.032) were significantly lower in the LMA group. The incidences of delayed recovery or delirium (p = 0.027), laryngeal or airway injury (p = 0.016), cough or bucking (p = 0.001), and sore throat (p < 0.001) were significantly lower in the LMA group. There were no statistically significant differences in catheter stability parameters and sinus rhythm maintenance rates between the two groups (p > 0.05). CONCLUSION: LMA is feasible, safe, and effective in AF CA as an optimized airway management technique for GA.

15.
J Pediatr Surg ; 59(4): 660-666, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38171956

RESUMO

OBJECTIVE: To elucidate the safety and effectiveness of laryngeal mask airway (LMA) use in pediatric patients undergoing laparoscopic inguinal hernia repair. METHODS: Studies were searched on the PubMed, EMBASE, and Cochrane Library databases. Only randomized controlled trials (RCTs) were included. Primary outcomes were major perioperative respiratory adverse events (PRAEs), namely laryngospasm, bronchospasm, desaturation, and aspiration. Secondary outcomes were minor PRAEs, anesthesia time, and recovery time. A meta-analysis was performed to calculate risk ratios (RR), weighted mean difference (WMD), and 95 % confidence intervals (CI) by using random effects models. RESULTS: In total, 5 RCTs comprising 402 patients were included. Regarding major PRAEs, laryngospasm (RR: 0.43, 95 % CI: 0.12 to 1.47; p = 0.18), bronchospasm, and aspiration all demonstrated no difference between the laryngeal and endotracheal groups. Desaturation exhibited a trend, but this trend was not sufficiently supported with statistical evidence (p = 0.09). For minor PRAEs, fewer patients experienced incidence of cough after laryngeal mask use (RR: 0.27, 95 % CI: 0.11 to 0.67; p = 0.005). Other PRAE, namely hoarseness (p = 0.06), sore throat (RR: 1.88, 95 % CI: 0.76 to 4.66; p = 0.18), and stridor, did not differ between the 2 groups. Additionally, both anesthesia time (WMD: -6.88 min, 95 % CI: -11.88 to -1.89; p < 0.00001) and recovery time (WMD: -4.85 min, 95 % CI: -6.51 to -3.19; p < 0.00001) were shortened in the LMA group. CONCLUSION: LMA used in pediatric laparoscopic inguinal hernia repair demonstrated no greater safety risks than endotracheal tube intubation did. Thus, anesthesiologists may shift from conventional endotracheal tube use to LMA use. Moreover, anesthesia and recovery times were shortened in the LMA group, which resulted in more efficient use of the operating room. Because of these benefits, LMA could be an appropriate option for pediatric patients undergoing laparoscopic inguinal hernia repair. LEVEL OF EVIDENCE: Treatment Study, LEVEL III.


Assuntos
Espasmo Brônquico , Hérnia Inguinal , Laparoscopia , Máscaras Laríngeas , Laringismo , Transtornos Respiratórios , Criança , Humanos , Máscaras Laríngeas/efeitos adversos , Laringismo/epidemiologia , Laringismo/etiologia , Espasmo Brônquico/complicações , Hérnia Inguinal/complicações , Intubação Intratraqueal/efeitos adversos , Transtornos Respiratórios/etiologia , Laparoscopia/efeitos adversos
16.
Acta Anaesthesiol Scand ; 68(2): 178-187, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37877551

RESUMO

BACKGROUND: Few clinical studies investigate technical skill performance in experienced clinicians. METHODS: We undertook a prospective observational study evaluating procedural skill competence in consultant anaesthetists who performed flexible bronchoscopic intubation (FBI) under continuous ventilation through a second-generation supraglottic airway device (SAD). Airway management was recorded on video and performance evaluated independently by three external assessors. We included 100 adult patients undergoing airway management by 25 anaesthetist specialists, each performing four intubations. We used an Objective Structured Assessment of Technical Skills-inspired global rating scale as primary outcome. Further, we assessed the overall pass rate (proportion of cases where the average of assessors' evaluation for every domain scored ≥3); the progression in the global rating scale score; time to intubation; self-reported procedural confidence; and pass rate from the first to the fourth airway procedure. RESULTS: Overall median global rating scale score was 29.7 (interquartile range 26.0-32.7 [range 16.7-37.7]. At least one global rating scale domain was deemed 'not competent' (one or more domains in the evaluation was scored <3) in 30% of cases of airway management, thus the pass rate was 70% (95% CI 60%-78%). After adjusting for multiple testing, we found a statistically significant difference between the first and fourth case of airway management regarding time to intubation (p = .006), but no difference in global rating scale score (p = .018); self-reported confidence before the procedure (p = .014); or pass rate (p = .109). CONCLUSION: Consultant anaesthetists had a median global rating scale score of 29.7 when using a SAD as conduit for FBI. However, despite reporting high procedural confidence, at least one global rating scale domain was deemed 'not competent' in 30% of cases, which indicates a clear potential for improvement of skill competence among professionals.


Assuntos
Intubação Intratraqueal , Máscaras Laríngeas , Adulto , Humanos , Intubação Intratraqueal/métodos , Consultores , Manuseio das Vias Aéreas/métodos , Broncoscopia , Anestesiologistas
17.
J Perianesth Nurs ; 39(1): 48-57.e3, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37831044

RESUMO

PURPOSE: The purpose of this article is to compare the safety of the laryngeal mask airway ProSeal (PLMA) and the streamlined liner of the pharynx airway (SLIPA) during general anesthesia. DESIGN: This study is a systematic review and meta-analysis. METHODS: Two authors performed searches of Embase, Web of Science, and PubMed to identify clinical trials that compared PLMA and SLIPA in patients receiving general anesthesia. Relative risk (RR) with corresponding 95% confidence intervals (CI) were used to pool the dichotomous data. The mean difference (MD) and the associated 95% CI were applied to pool continuous data. RevMan 5.0 software was used for data analysis. FINDINGS: A total of 15 studies with 1263 patients were included. There was no significant difference between PLMA and SLIPA in the rate of insertion success on the first attempt (RR = 1.02, 95% CI [0.95, 1.09], P = .59), airway sealing pressure (MD = 0.75, 95% CI [-0.09, 1.58], P = .08) and the incidence of a sore throat (RR = 0.85, 95% CI [0.7, 1.04], P = .12). The insertion time of PLMA was shorter than SLIPA (MD = 5.24, 95% CI [0.51, 9.98], P = .03), and the incidence of bloodstaining on the device was lower (RR = 0.72, 95% CI [0.55, 0.94], P = .02). CONCLUSIONS: Both devices have a high rate of insertion success on the first attempt and airway sealing pressure. But PLMA has a shorter insertion time and less incidence of blood staining, which is more advantageous than SLIPA.


Assuntos
Máscaras Laríngeas , Faringite , Humanos , Máscaras Laríngeas/efeitos adversos , Faringe , Anestesia Geral/efeitos adversos , Intubação Intratraqueal , Faringite/etiologia
19.
Laryngoscope ; 2023 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-38095278

RESUMO

OBJECTIVE: To evaluate the safety and efficacy of endoscopic treatment of subglottic stenosis with flexible bronchoscopy via laryngeal mask airway (LMA) approach. METHODS: The records of all patients who underwent endoscopic surgery for subglottic stenosis (SGS) from November 2019 to January 2023 at an academic medical center were reviewed with attention to demographics, patient comorbidities, airway stenosis characteristics, operative time details, surgical complications, and post-operative course. All patients, >18 years old, with one or more surgeries for SGS using (LMA) for intraoperative airway management were included. Surgeries with suspension microlaryngoscopy were excluded. Patients with glottic stenosis or tracheotomy were excluded. RESULTS: Thirty-five patients underwent 52 procedures meeting inclusion criteria. Mean age was 55 years (range 31-78, SD 13.3) and 33 patients (94%) were female. Mean BMI was 30.9 (range 18.4-60.5, SD 8.8). The most common etiology of stenosis was intubation injury in 17 patients (49%), followed by idiopathic in 13 patients (37%). Cotton-Meyer grade 3 (71-99% narrowing) was seen in 25 patients (71%). Mean anesthesia and surgical operative times were 75.9 min (SD 13.5 min) and 39.7 min (SD 11.0 min), respectively. Mean SpO2 nadir was 94.5% (SD 6.3%). No patients required intraoperative change to rigid laryngoscopy, intubation, or tracheotomy. There were no post-operative complications. Mean surgery-free interval was 12.2 months (SD 6.3). CONCLUSION: Endoscopic treatment of subglottic stenosis with flexible bronchoscopy and spontaneous ventilation via LMA approach is a safe and effective option, especially in patients with limitations for rigid laryngoscopy and elevated BMI. LEVEL OF EVIDENCE: Level Four (case series) Laryngoscope, 2023.

20.
Front Med (Lausanne) ; 10: 1252586, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38116036

RESUMO

Background: Transnasal humidified rapid-insufflation ventilator exchange (THRIVE) has the characteristics of operating easily and maintaining oxygenation and eliminating CO2, which makes it possible to be used in endoscopic thoracic sympathectomy (ETS). The application of THRIVE in ETS remains undefined. The purpose of this randomized controlled study is to assess the efficacy between THRIVE and laryngeal mask airway (LMA) for ETS. Methods: In total, 34 patients from May 2022 to May 2023 in Huazhong University of Science and Technology Union Shenzhen Hospital undergoing ETS were randomly divided into a THRIVE group (n = 17) and an LMA group (n = 17). A serial arterial blood gas analysis was conducted during the perioperative period. The primary outcome was the arterial partial pressure of carbon dioxide (PaCO2) during the perioperative period. The secondary outcome was arterial partial pressure of oxygen (PaO2) during the perioperative period. Results: The mean (SD) highest PaCO2 in the THRIVE group and LMA group were 99.0 (9.0) mmHg and 51.7 (5.2) mmHg, respectively (p < 0.001). The median (inter-quartile range) time to PaCO2 ≥ 60 mmHg in the THRIVE group was 26.0 min (23.2-28.8). The mean (SD) PaO2 was 268.8 (89.0) mmHg in the THRIVE group and 209.8 (55.8) mmHg in the LMA group during surgery (p = 0.027). Conclusion: CO2 accumulation in the THRIVE group was higher than that of the LMA group during ETS, but THRIVE exhibited greater oxygenation capability compared to LMA. We preliminarily testified that THRIVE would be a feasible non-intubated ventilation technique during ETS under monitoring PaCO2.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...