RESUMO

The effectiveness of radiation therapy in the treatment of cerebral cavernous malformations (CCM) remains debatable. However, numerous studies have shown a reduction in hemorrhage risk following radiotherapy for CCM. Therefore, herein, we share our experiences utilizing linear accelerator (LINAC)-based radiation for treating CCMs, with the aim of identifying the key factors influencing the therapeutic outcomes. We conducted a retrospective review of all patients with non-brainstem CCMs who underwent radiation treatment, as recorded in the NOVALIS registry at our institution. T2-weighted MR images were used for volumetric assessments using the iPlan radiotherapy planning software. To determine the independent predictors of nidus volume reduction and perilesional brain edema (PBE), we performed multivariate Cox regression analysis to calculate hazard ratios. Twenty patients with 31 non-brainstem CCMs were enrolled in this study. Analysis revealed age as an independent predictive factor for both nidus volume reduction and PBE after radiation treatment for CCM. Furthermore, a single fraction dose of 17 Gy or more was identified as an independent predictor of nidus volume decrease, while a single fraction dose of 18 Gy or more was found to be an independent risk factor for PBE in patients with CCM following LINAC-based radiation therapy. LINAC-based radiation therapy for non-brainstem CCMs with a single fraction radiation dose between 16.5 and 17.5 Gy, or a biologically equivalent dose of approximately 120 Gy, may be the most effective at reducing nidus volume and limiting side effects, particularly in patients under the age of 55 years. We further observed that the risk of PBE increased as the maximum radiation dose delivered to a 1 cc volume of the surrounding normal brain exceeded approximately 17.3 Gy. Therefore, we believe that calculating the D1cc of the normal brain may help to predict the occurrence of PBE when radiotherapy is administered to non-brainstem CCMs.

2.
Radiother Oncol ; 196: 110308, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38677330

RESUMO

AIM: To validate a fully-automated lexicographic optimization-planning system (mCycle, Elekta) for single-(SL) and multiple-(ML, up to 4 metastases) lesions in intracranial stereotactic radiosurgery (SRS, 21 Gy, single fraction). METHODS: A pre-determined priority list, Wish-List (WL), represents a dialogue between planner and clinician, establishing strict constraints and pursuing objectives. In order to satisfy the clinical protocol without manual intervention, four patients were required to tweak and fine-tune each WL (SLp, MLp) for coplanar arcs. Thirty-five testing plans (20 SLp, 15 MLp) were automatically re-planned (mCP). Automatic and manual plans were compared including dose constraints, conformality, modulation complexity score (MCS), delivery time, and local gamma analysis (2%/2 mm). To ensure plan clinical acceptability, two radiation oncologists conducted an independent blind plan choice. RESULTS: Each WL-tuning took 3 days. Estimated median manual plans and mCP calculation time were 8 and 3 h, respectively. Significant increases in SLp and MLp target coverage and conformity were registered. mCP showed a not significant and clinically acceptable higher median brain V12Gy. SLp registered a -5.8% MU decrease with comparable median delivery time (MP 2.0 min, mCP 1.9 min) while MLp showed a +9.8% MU increase and longer delivery time (MP 3.5 min, mCP 4.4 min). mCP MCS resulted significantly higher without affecting gamma passing rates. At blind choice, mCP were preferred in the majority of cases. CONCLUSIONS: Lexicographic optimization produced acceptable SRS plans with coplanar arcs significantly reducing the overall planning time in cases with up to 4 brain metastases. These planning improvements suggest further investigations by setting high-quality non-coplanar arc plans as a reference.


Assuntos
Neoplasias Encefálicas , Radiocirurgia , Planejamento da Radioterapia Assistida por Computador , Humanos , Radiocirurgia/métodos , Neoplasias Encefálicas/secundário , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/cirurgia , Neoplasias Encefálicas/diagnóstico por imagem , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica
3.
Pathol Oncol Res ; 30: 1611589, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38414671

RESUMO

Aim: This single institute prospective study aimed to evaluate the feasibility of LINAC-based stereotactic body radiotherapy (SBRT) in treating patients with early-stage non-small cell lung cancer (NSLSC). We focused on the survival data with the local and distant control profiles and the cancer- and non-cancer-specific survival. Treatment-related side effects were also collected and analyzed. Methods: Patients with early-stage NSCLC between January 2018 and October 2021 were included in our prospective study; a total of 77 patients receiving LINAC-based SBRT were analyzed. All patients had pretreatment multidisciplinary tumor board decisions on SBRT. The average patient age was 68.8 years (median: 70 years, range: 52-82); 70 patients were in ECOG 0 status (91%), while seven patients were in ECOG 1-2 status (9%). 52% of the patients (40) had histologically verified NSCLC, and the other 48% were verified based on PETCT results. We applied the SBRT scheme 8 x 7.5 Gy for central tumors (74%) or 4 x 12 Gy for peripheral tumors (26%). Results: The mean follow-up time was 25.4 months (median 23, range 18-50). The Kaplan-Meier estimation for overall survival in patients receiving LINAC-based SBRT was 41.67 months. Of the 77 patients treated by SBRT, death was reported for 17 patients (9 cases cancer-specific, 8 cases non-cancer specific reason). The mean local tumor control was 34.25 months (range 8.4-41), and the mean systemic control was 24.24 months (range 7-25). During the treatments, no Grade I-II were reported; in 30 cases, Grade I non-symptomatic treatment-related lung fibrosis and two asymptomatic rib fractures were reported. Conclusion: In the treatment of early-stage NSCLC, LINAC-based SBRT can be a feasible alternative to surgery. Although we reported worse OS data in our patient cohort compared to the literature, the higher older average age and the initial worse general condition (ECOG1-2) in our patient cohort appear to be the reason for this difference. With the comparable local control and survival data and the favorable side effect profile, SBRT might be preferable over surgery in selected cases.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Radiocirurgia , Carcinoma de Pequenas Células do Pulmão , Humanos , Idoso , Carcinoma Pulmonar de Células não Pequenas/patologia , Neoplasias Pulmonares/patologia , Radiocirurgia/efeitos adversos , Estudos Prospectivos , Análise de Sobrevida , Carcinoma de Pequenas Células do Pulmão/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
4.
Radiat Oncol ; 19(1): 19, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38326813

RESUMO

BACKGROUND: To compare the dosimetric quality of three widely used techniques for LINAC-based single-isocenter multi-target multi-fraction stereotactic radiosurgery (fSRS) with more than 20 targets: dynamic conformal arc (DCA) in BrainLAB Multiple Metastases Elements (MME) module and volumetric modulated arc therapy (VMAT) using RapidArc (RA) and HyperArc (HA) in Varian Eclipse. METHODS: Ten patients who received single-isocenter fSRS with 20-37 targets were retrospectively replanned using MME, RA, and HA. Various dosimetric parameters, such as conformity index (CI), Paddick CI, gradient index (GI), normal brain dose exposures, maximum organ-at-risk (OAR) doses, and beam-on times were extracted and compared among the three techniques. Wilcoxon signed-rank test was used for statistical analysis. RESULTS: All plans achieved the prescribed dose coverage goal of at least 95% of the planning target volume (PTV). HA plans showed superior conformity compared to RA and MME plans. MME plans showed superior GI compared to RA and HA plans. RA plans resulted in significantly higher low and intermediate dose exposure to normal brain compared to HA and MME plans, especially for lower doses of ≥ 8Gy and ≥ 5Gy. No significant differences were observed in the maximum dose to OARs among the three techniques. The beam-on time of MME plans was about two times longer than RA and HA plans. CONCLUSIONS: HA plans achieved the best conformity, while MME plans achieved the best dose fall-off for LINAC-based single-isocenter multi-target multi-fraction SRS with more than 20 targets. The choice of the optimal technique should consider the trade-offs between dosimetric quality, beam-on time, and planning effort.


Assuntos
Neoplasias Encefálicas , Endrin/análogos & derivados , Radiocirurgia , Radioterapia de Intensidade Modulada , Humanos , Radiocirurgia/métodos , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/cirurgia , Neoplasias Encefálicas/secundário , Dosagem Radioterapêutica , Estudos Retrospectivos , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos
5.
J Xray Sci Technol ; 32(3): 765-781, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38277334

RESUMO

BACKGROUND: SRS and SRT are precise treatments for brain metastases, delivering high doses while minimizing doses to nearby organs. Modern linear accelerators enable the precise delivery of SRS/SRT using different modalities like three-dimensional conformal radiotherapy (3DCRT), intensity-modulated radiotherapy (IMRT), and Rapid Arc (RA). OBJECTIVE: This study aims to compare dosimetric differences and evaluate the effectiveness of 3DCRT, IMRT, and Rapid Arc techniques in SRS/SRT for brain metastases. METHODS: 10 patients with brain metastases, 3 patients assigned for SRT, and 7 patients for SRS. For each patient, 3 treatment plans were generated using the Eclipse treatment planning system using different treatment modalities. RESULTS: No statistically significant differences were observed among the three techniques in the homogeneity index (HI), maximum D2%, and minimum D98% doses for the target, with a p > 0.05. The RA demonstrated a better conformity index of 1.14±0.25 than both IMRT 1.21±0.26 and 3DCRT 1.37±0.31. 3DCRT and IMRT had lower Gradient Index values compared to RA, suggesting that they achieved a better dose gradient than RA. The mean treatment time decreased by 26.2% and 10.3% for 3DCRT and RA, respectively, compared to IMRT. In organs at risk, 3DCRT had lower maximum doses than IMRT and RA, but some differences were not statistically significant. However, in the brain stem and brain tissues, RA exhibited lower maximum doses compared to IMRT and 3DCRT. Additionally, RA and IMRT had lower V15Gy, V12Gy, and V9Gy values compared to 3DCRT. CONCLUSION: While 3D-CRT delivered lower doses to organs at risk, RA and IMRT provided better conformity and target coverage. RA effectively controlled the maximum dose and irradiated volume of normal brain tissue. Overall, these findings indicate that 3DCRT, RA, and IMRT are suitable for treating brain metastases in SRS/SRT due to their improved dose conformity and target coverage while minimizing dose to healthy tissues.


Assuntos
Neoplasias Encefálicas , Radiocirurgia , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Neoplasias Encefálicas/secundário , Neoplasias Encefálicas/radioterapia , Radiocirurgia/métodos , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Estudos de Viabilidade , Masculino , Feminino , Radioterapia Conformacional/métodos , Pessoa de Meia-Idade , Idoso
6.
Radiat Oncol ; 18(1): 28, 2023 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-36750848

RESUMO

BACKGROUND: Comparative prospective data regarding different radiosurgery (SRS) modalities for treating brain metastases (BMs) from solid tumors are not available. To investigate with a single institute phase III randomized trial whether SRS executed with linac (Arm-B) is superior to a dedicated multi-source gamma-ray stereotactic platform (Arm-A). METHODS: Adults patients with 1-4 BMs from solid tumors up to 30 mm in maximum diameter were randomly assigned to arms A and B. The primary endpoint was cumulative incidence of symptomatic (grade 2-3) radionecrosis (CIRN). Secondary endpoints were local progression cumulative incidence (CILP), distant brain failure, disease-free survival (DFS), and overall survival (OS). RESULTS: A total of 251 patients were randomly assigned to Arm-A (121) or Arm-B (130). The 1-year RN cumulative incidence was 6.7% in whole cohort, 3.8% (95% CI 1.9-7.4%) in Arm-B, and 9.3% (95% CI 6.2-13.8%) in the Arm-A (p = 0.43). CIRN was influenced by target volume irradiated only for the Arm-A (p << 0.001; HR 1.36 [95% CI 1.25-1.48]). Symptomatic RN occurred in 56 cases at a median time of 10.3 months (range 1.15-54.8 months), 27 in the Arm-B at a median time of 15.9 months (range 4.9-54.8 months), and 29 in the Arm-A at a median time of 6.9 months (1.2-32.3 months), without statistically significant differences between the two arms. No statistically significant differences were recorded between the two arms in CILP, BDF, DFS or OS. The mean beam-on time to deliver SRS was 49.0 ± 36.2 min in Arm-A, and 3.1 ± 1.6 min in Arm-B. CONCLUSIONS: Given the technical differences between the treatment platforms investigated in this single-institution study, linac-based SRS (Arm-B) did not lead to significantly lower grade 2-3 RN rates versus the multi-source gamma-ray system (Arm-A) in a population of patients with limited brain metastases of small volume. No significant difference in local control was observed between both arms. For Arm-B, the treatment delivery time was significantly lower than for Arm-A. TRIAL REGISTRATION: ClinicalTrials.gov Identifier NCT02355613.


Assuntos
Neoplasias Encefálicas , Radiocirurgia , Adulto , Humanos , Radiocirurgia/métodos , Estudos Prospectivos , Estudos Retrospectivos , Neoplasias Encefálicas/secundário , Intervalo Livre de Progressão , Resultado do Tratamento
7.
Radiat Oncol ; 17(1): 213, 2022 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-36578021

RESUMO

BACKGROUND: Linac-based fractionated stereotactic radiotherapy (fSRT) and stereotactic radiosurgery (SRS) are increasingly being used to manage patients with multiple metastases. This retrospective cohort study aimed to compare the outcomes after linac-based fSRT and SRS between three patient groups classified based on the number of brain metastases (BMs): 1 BM, 2-4 BM, 5-10 BM. METHODS: The data of consecutive patients with 1-10 BMs treated with fSRT or SRS between July 2016 and June 2018 at a single institution were collected. Patients with previous whole-brain radiotherapy (WBRT), concurrent use of WBRT, or surgical resection were excluded from the analysis. A total of 176 patients were classified into three groups according to the number of BMs: 78, 67, and 31 patients in 1 BM, 2-4 BM, and 5-10 BM, respectively. The Kaplan-Meier method was used to estimate overall survival (OS) curves, and the cumulative incidence with competing risks was used to estimate local control (LC), distant intracranial failure (DIF), and radiation necrosis (RN). RESULTS: Median OS was 19.8 months (95% confidence interval [CI] 10.2-27.5), 7.3 months (4.9-11.1), and 5.1 months (4.0-9.0) in 1 BM, 2-4 BM, and 5-10 BM, respectively. Compared to 2-4 BM, 1 BM had significantly better OS (hazard ratio [HR] 0.59, 95% CI 0.40-0.87; p = 0.0075); however, 5-10 BM had comparable OS (HR 1.36, 95% CI 0.85-2.19; p = 0.199). There was no significant difference in LC, DIF, and RN between tumor number groups, but DIF was lower in 1 BM. RN of grade 2 or higher occurred in 21 patients (13.5%); grade 4 and 5 RN were not observed. CONCLUSIONS: The linac-based fSRT and SRS for patients with 5-10 BMs is comparable to that for patients with 2-4 BMs in OS, LC, DIF, and RN. It seems reasonable to use linac-based fSRT and SRS in patients with 5-10 BMs.


Assuntos
Neoplasias Encefálicas , Lesões por Radiação , Radiocirurgia , Humanos , Radiocirurgia/métodos , Resultado do Tratamento , Estudos Retrospectivos , Estudos de Viabilidade , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/cirurgia , Neoplasias Encefálicas/secundário , Lesões por Radiação/etiologia
8.
Cureus ; 14(10): e29955, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36348852

RESUMO

Background Although international publications on radiosurgery have increased exponentially, reports of heterogeneous series treated with linear accelerator (LINAC) are scarce. Since most intracranial tumors are irregular in size and not spherical, LINACs (Elekta Precise®, Elekta AB, Sweden), fitted with a multi-leaf collimator, allow for precise stereotactic radiosurgery for the entire tumor. Aim To evaluate the effects of LINAC on an outpatient basis with patients diagnosed with various intracranial malignancies. Methodology A retrospective observational study of a series of cases of patients with intracranial lesions treated at the Institute of Oncology and Radiobiology using LINAC was carried out from October 2019 to May 2021 to evaluate the therapeutic results of radiosurgery in patients with intracranial tumors. Results A total of 22 lesions in 20 patients were treated with LINAC. The average age of the patients was 49.7, and the male-female ratio was 1:2. The cases consisted were mostly vestibular schwannoma (7 lesions), metastases from breast cancer (3 lesions), and tuberculum sellae meningioma (2 lesions). The prescription dose covered 99% of the planning target volume in 16 lesions (72.7%) and 100% in six lesions (27.3%) (prescription volume). In meningiomas and schwannomas, doses between 12 and 14 Gy were used, in plasmacytoma 13 Gy, in pilocytic astrocytoma 14 Gy, in cavernoma 15 Gy, in breast cancer metastasis between 18 and 20 Gy, and in lung cancer metastasis 22 Gy. When evaluating local control, 11 patients exhibited stable findings at the six-month control while 10 had partial regression, and a single patient had total regression. Minor complications such as perilesional edema, facial paresthesia, facial paralysis, and transient alopecia were observed in eight of the patients. Conclusions Patients with extra-axial, low-grade malignancy, and posterior fossa lesions were predominant in the studied population. Radiosurgery treatment is associated with good local control of the treated lesions. Complications are infrequent, mild, and predominated by perilesional edema.

9.
Front Oncol ; 12: 846609, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35345445

RESUMO

Background and Purpose: The treatment options available in the management of brain metastases includes fractionated stereotactic radiotherapy (FSRT) and stereotactic radiosurgery (SRS) treatments. FSRT treatments have proved to be useful mainly in the treatment of larger volumes. This study aims to evaluate the FSRT treatment technique used in our department based on various plan quality indices. Methods and Materials: 24 treatment plans of 23 patients were analyzed. Volumetric modulated arc therapy (VMAT) plans were generated in line with the department protocol. The following parameters were extracted: Radiation Therapy Oncology Group conformity index (RTOG CI), Paddick conformity index (Paddick CI), gradient index (GI), quality index (Q), homogeneity index (HI), and V24.4 volume as a parallel index of V12 used at SRS plan evaluation. Results: Plan conformity was acceptable, RTOG CI mean was 0.942; Paddick CI mean was 0.824. The mean GI value was 6.146. The mean of HI and Q indices were 1.263 and 0.94, respectively. V24.4 mean was 33.434 cm3. All plans achieved clinically acceptable organs-at-risk (OAR) constraints. PTV volumes were clustered into either 10 cm3 or 15 cm3 bins depending on the plan quality metric we used. The mean values show a balanced distribution of plan indices along the various PTV bins. Discussion: Our results based on the derived indices show that our FSRT approach can achieve clinically acceptable treatment plans. Furthermore, the clustering of PTV volumes show that these plan quality metrics remain acceptable for a wide spectrum of PTV volumes.

10.
Clin. transl. oncol. (Print) ; 23(8): 1561-1570, ago. 2021. graf
Artigo em Inglês | IBECS | ID: ibc-222154

RESUMO

Purpose Radiosurgery (SRS) is an effective treatment option for brain metastases (BMs). Long-term results of the first worldwide experience with a mono-isocentric, non-coplanar, linac-based stereotactic technique in the treatment of multiple BMs are reported. Methods patients with multiple BMs, life expectancy > 3 months, and good performance status (≤ 2) were treated with simultaneous SRS with volumetric modulated arc technique. Data were retrospectively evaluated. Results 172 patients accounting for 1079 BMs were treated at our institution from 2017 to 2020. The median number of treated metastases was 4 (range 2–22). Primary tumor histology was: lung (44.8%), breast (32%), and melanoma (9.4%). The 2-year LPFS was 71.6%, respectively. A biological effective dose (BED) ≥ 51.3 Gy10 correlated with higher local control. Uncontrolled systemic disease and melanoma histology were independent prognostic factors correlated with decreased iPFS. Patients with > 10 BMs had a trend towards shorter iPFS (p = 0.055). 31 patients received multiple SRS courses (2–7) in case of intracranial progression. The median iOS was 22.4 months. Brainstem metastases and total PTV > 7.1 cc correlated with shorter iOS. The 1- and 2-year WBRT-free survival was 83.2% and 61.1%, respectively. Conclusion Long-term results in a large patient population treated with a mono-isocentric, dedicated technique demonstrated its effectiveness and safety also in the case of multiple courses. The shortened treatment time and the possibility to safely spare healthy brain tissue allows the safe treatment of patients with a large number of metastases and to deliver multiple courses of SRS. In selected cases, the administration of WBRT can be delayed (AU)


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Radiocirurgia/métodos , Neoplasias Encefálicas/secundário , Neoplasias Encefálicas/cirurgia , Melanoma/patologia , Neoplasias da Mama/patologia , Neoplasias Pulmonares/patologia , Resultado do Tratamento , Fatores de Tempo , Estudos Retrospectivos , Intervalo Livre de Progressão , Recidiva Local de Neoplasia , Neoplasias Encefálicas/mortalidade , Neoplasias Encefálicas/radioterapia
11.
Cureus ; 13(6): e15475, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34262813

RESUMO

Objectives Brain metastases (BM) are the most common intracranial tumors in adults. Surgery and frame-based stereotactic radiosurgery (SRS) are well-described treatment options. Frameless SRS is an emerging BM treatment option offering fewer side effects. The aim of this study was to describe the therapeutic outcomes and toxicity of frameless SRS with linear accelerator (LINAC)-based technology for BM treatment in our institution. Materials and methods We performed a retrospective study including all adult patients treated with frameless SRS with LINAC-based technology for BM between October 2010 and July 2016. Patients were followed routinely with MRI scans at three-month intervals. Primary endpoints were progression-free survival, local control, overall survival, and toxicity related to the treatment. All survival times were computed with the Kaplan-Meier method. All cumulative incidences were computed using competing risk analyses. Results A total of 194 metastatic lesions in 141 patients were treated in a 69-month interval. At the time of analysis, 33 patients were still alive, with a median follow-up time of 25.1 months. The overall median survival was 8.7 months. The median progression-free survival was 5.3 months. Local recurrence as a first event was 25% and 38% at one and two years, respectively, while distant brain recurrence as a first event was 18% and 21%. Death before any brain event occurred in 31% of patients. The cumulative incidence of radiation necrosis as a first brain event was 2% at one and two years. Conclusions The treatment of BM with LINAC-based frameless SRS in our institution had an overall and progression-free survival comparable with the literature for frameless SRS and for conventional frame-based SRS while being less invasive and more comfortable for the patient. In our study, frameless SRS with LINAC technology seems to be safe for BM treatment with minimal rates of radiation necrosis.

12.
Cancers (Basel) ; 13(14)2021 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-34298671

RESUMO

The purpose was to compare linac-based stereotactic radiosurgery and hypofractionated radiotherapy plan quality of automated planning, intensity modulated radiotherapy (IMRT) and manual dynamic conformal arc (DCA) plans as well as single- and multiple-isocenter techniques for multiple brain metastases (BM). For twelve patients with four to ten BM, seven non-coplanar linac-based plans were created: a manually planned DCA plan with a separate isocenter for each metastasis, a single-isocenter dynamic IMRT plan, an automatically generated single-isocenter volumetric modulated arc radiotherapy (VMAT) plan, four automatically generated single-isocenter DCA plans with three or five couch angles, with high or low sparing of normal tissue. Paddick conformity index, gradient index (GI), mean dose, total V12Gy and V5Gy of uninvolved brain, number of monitor units (MUs), irradiation time and pass rate were compared. The GI was significantly higher for VMAT than for separate-isocenter, IMRT, and all automatically generated plans. The number of MUs was lowest for VMAT, followed by automatically generated DCA and IMRT plans and highest for manual DCA plans. Irradiation time was the shortest for automatically planned DCA plans. Automatically generated linac-based single-isocenter plans for multiple BM reduce the number of MUs and irradiation time with at least comparable GI and V5Gy relative to the reference separate-isocenter DCA plans.

13.
Clin Transl Oncol ; 23(8): 1561-1570, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33570720

RESUMO

PURPOSE: Radiosurgery (SRS) is an effective treatment option for brain metastases (BMs). Long-term results of the first worldwide experience with a mono-isocentric, non-coplanar, linac-based stereotactic technique in the treatment of multiple BMs are reported. METHODS: patients with multiple BMs, life expectancy > 3 months, and good performance status (≤ 2) were treated with simultaneous SRS with volumetric modulated arc technique. Data were retrospectively evaluated. RESULTS: 172 patients accounting for 1079 BMs were treated at our institution from 2017 to 2020. The median number of treated metastases was 4 (range 2-22). Primary tumor histology was: lung (44.8%), breast (32%), and melanoma (9.4%). The 2-year LPFS was 71.6%, respectively. A biological effective dose (BED) ≥ 51.3 Gy10 correlated with higher local control. Uncontrolled systemic disease and melanoma histology were independent prognostic factors correlated with decreased iPFS. Patients with > 10 BMs had a trend towards shorter iPFS (p = 0.055). 31 patients received multiple SRS courses (2-7) in case of intracranial progression. The median iOS was 22.4 months. Brainstem metastases and total PTV > 7.1 cc correlated with shorter iOS. The 1- and 2-year WBRT-free survival was 83.2% and 61.1%, respectively. CONCLUSION: Long-term results in a large patient population treated with a mono-isocentric, dedicated technique demonstrated its effectiveness and safety also in the case of multiple courses. The shortened treatment time and the possibility to safely spare healthy brain tissue allows the safe treatment of patients with a large number of metastases and to deliver multiple courses of SRS. In selected cases, the administration of WBRT can be delayed.


Assuntos
Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/secundário , Irradiação Craniana/métodos , Radiocirurgia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias Encefálicas/mortalidade , Neoplasias da Mama/patologia , Estudos de Coortes , Irradiação Craniana/efeitos adversos , Irradiação Craniana/instrumentação , Feminino , Humanos , Estimativa de Kaplan-Meier , Neoplasias Pulmonares/patologia , Masculino , Melanoma/radioterapia , Melanoma/secundário , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/radioterapia , Órgãos em Risco/efeitos da radiação , Intervalo Livre de Progressão , Lesões por Radiação/prevenção & controle , Radiocirurgia/efeitos adversos , Radiocirurgia/instrumentação , Dosagem Radioterapêutica , Eficiência Biológica Relativa , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
15.
Clin Exp Metastasis ; 37(1): 77-83, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31691873

RESUMO

Stereotactic radiosurgery (SRS) is an effective treatment option for multiple brain metastases (BMs). Modern mono-isocentric techniques allow the delivery of multiple stereotactic courses, in the event of intracranial failure. Nevertheless, limited data on effectiveness and toxicity have been reported in comparison to WBRT. Aim of this retrospective matched-pair analysis was to compare patients affected by limited BMs treated with multiple SRS courses using a mono-isocentric, non-coplanar technique (HyperArc™, Varian Medical System) to upfront WBRT. One hundred and two patients accounting for 677 BMs were treated with HyperArc™. In case of further intracranial progression, 44 treatment courses of 201 metastases in 19 patients, were treated by subsequent HyperArc™ courses. This population was matched with 38 patients treated with WBRT. The median BMs number was 4 (range 2-10) for HyperArc™ and 5 (range 2-10) for WBRT. Overall survival (OS) and toxicity were evaluated. The median follow-up was 9 months (range 3-40 months). The median OS was not reached (range 5-22 months) for HyperArc™ patients and 8 months (range 3-40 months) for WBRT patients, while the 1-year OS was 77% and 34.6% for HyperArc™ and WBRT, respectively (p = 0.001; HR 4.77, 95% CI 1.62-14.00). There was one case of radionecrosis. HyperArc™ is an effective and safe technique for the treatment of multiple BMs. In selected cases of intracranial oligorecurrence, further subsequent courses can be safely delivered with the same technical approach. Moreover, in patients with a limited number of BMs, SRS showed an improved survival outcome when compared to WBRT.


Assuntos
Neoplasias Encefálicas/radioterapia , Irradiação Craniana/métodos , Recidiva Local de Neoplasia/radioterapia , Lesões por Radiação/epidemiologia , Radiocirurgia/métodos , Adulto , Idoso , Encéfalo/patologia , Encéfalo/efeitos da radiação , Neoplasias Encefálicas/mortalidade , Neoplasias Encefálicas/secundário , Irradiação Craniana/efeitos adversos , Progressão da Doença , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Análise por Pareamento , Pessoa de Meia-Idade , Necrose/epidemiologia , Necrose/etiologia , Recidiva Local de Neoplasia/mortalidade , Recidiva Local de Neoplasia/patologia , Intervalo Livre de Progressão , Lesões por Radiação/etiologia , Radiocirurgia/efeitos adversos , Retratamento/efeitos adversos , Retratamento/métodos , Estudos Retrospectivos , Resultado do Tratamento
16.
Radiat Oncol ; 14(1): 91, 2019 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-31159835

RESUMO

BACKGROUND: Although circular collimator arcs (CCA) and dynamic conformal arcs (DCA) are commonly used linear accelerator-based treatment planning techniques for intracranial stereotactic radiosurgery (SRS) of a small single lesion, these two techniques have not been rigorously compared in terms of tumor shape. Therefore, this study compared clinical CCA plans with re-planned DCA plans using conformity index (CI) and V12Gy (volume of normal brain tissue receiving 12 Gy or higher) from a perspective of asymmetry (Asym) of planning target volume (PTV). METHODS: Ninety-five clinical CCA plans delivered for a small single lesion with PTV size < 1.4 cm3 were selected and re-planned using DCA. PTV Asym (%) was defined and calculated from three dimensions of PTV. A pair of the 95 plans was first considered as one group without grouping and then categorized into two groups with respective to either PTV size or PTV Asym, and four groups with respect to PTV size and PTV Asym. For grouping, median values of PTV size and PTV Asym were used. A non-parametric paired test was performed for CI and V12Gy to compare CCA and DCA plans in each group. RESULTS: Median values of PTV size and PTV Asym were 0.415 cm3 (range: 0.076 cm3-1.369 cm3) and 6.12% (range: 0.52-25.74%), respectively. DCA plans had a lower average CI value than CCA plans for all groups. CCA plans had a smaller average V12Gy value than DCA plans for lesions with PTV Asym ≤6.12%, while CCA and DCA plans had similar average V12Gy values for lesions with PTV Asym > 6.12%. CONCLUSIONS: The DCA technique is recommended when a lesion has PTV Asym > 6.12% regardless of PTV size. For lesions with PTV Asym ≤6.12%, a technique choice would depend on the preference of CI or V12Gy.


Assuntos
Irradiação Craniana/métodos , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Encéfalo/patologia , Humanos , Dosagem Radioterapêutica , Estudos Retrospectivos
17.
J Cancer Res Clin Oncol ; 145(1): 193-200, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30382369

RESUMO

INTRODUCTION: Radiosurgery (SRS) or stereotactic fractionated radiotherapy (SFRT) is increasing in the treatment of brain metastases (BMs). Aim of the present study was to evaluate the safety and effectiveness of SRS/SFRT for BMs, using a new mono-isocenter non-coplanar solution (HyperArc™ Varian Medical System). METHODS: BMs patients with a diameter inferior to 3 cm, a life expectancy of more than 3 months and a good performance status, were eligible for Linac-based volumetric modulated arc therapy (VMAT) SFRT/SRS with HyperArc™. A retrospective analysis of patients and BMs was performed. RESULTS: From August 2017 to May 2018, 381 BMs in 64 patients were treated and 246 BMs (43 patients, median number of BMs: 5) of them were suitable for analysis. With a median FU time of 6 months, 244 out 246 (99%) BMs were controlled (18% complete response; 41% partial response, 40% stable disease), 2 BMs showed a progression, at the first control. No acute or late toxicities were reported. Median overall survival (OS) has not yet been achieved, while median time to progression was 5 months. In univariate analysis, statistically negative prognostic factors for OS were histology of primary tumor (p = 0.009): lung/breast cancer had better survival rates as compared to others. Cumulative intracranial volume disease ≥ 15 cc and systemic progression disease were independent prognostic factors for OS at univariate (p = 0.04; p = 0.005) and multivariate (p = 0.04; p = 0.009) analysis, respectively. CONCLUSION: The present first clinical data show that SFRT/SRS with HyperArc™ is safe and effective for BMs patients. The utilization of SFRT/SRS for BMs is promising and should be further explored in randomized trials.


Assuntos
Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/secundário , Radiocirurgia/métodos , Adulto , Idoso , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Radiocirurgia/efeitos adversos , Radiocirurgia/instrumentação , Estudos Retrospectivos , Análise de Sobrevida , Resultado do Tratamento , Carga Tumoral
18.
J Appl Clin Med Phys ; 18(2): 136-143, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28300370

RESUMO

PURPOSE/OBJECTIVES: To present our linac-based SRS procedural technique for medically and/or surgically refractory trigeminal neuralgia (TN) treatment and simultaneously report our clinical outcomes. MATERIALS AND METHODS: Twenty-seven refractory TN patients who were treated with a single fraction of 80 Gy to TN. Treatment delivery was performed with a 4 mm cone size using 7-arc arrangement with differential-weighting for Novalis-TX with six MV-SRS (1000 MU/min) beam and minimized dose to the brainstem. Before each treatment, Winston-Lutz quality assurance (QA) with submillimeter accuracy was performed. Clinical treatment response was evaluated using Barrow Neurological Institute (BNI) pain intensity score, rated from I to V. RESULTS: Out of 27 patients, 22 (81%) and 5 (19%) suffered from typical and atypical TN, respectively, and had median follow-up interval of 12.5 months (ranged: 1-53 months). For 80 Gy prescriptions, delivered total average MU was 19440 ± 611. Average beam-on-time was 19.4 ± 0.6 min. Maximum dose and dose to 0.5 cc of brainstem were 13.4 ± 2.1 Gy (ranged: 8.4-15.9 Gy) and 3.6 ± 0.4 Gy (ranged: 3.0-4.9 Gy), respectively. With a median follow-up of 12.5 months (ranged: 1-45 months) in typical TN patients, the proportion of patients achieving overall pain relief was 82%, of which half achieved a complete pain relief with BNI score of I-II and half demonstrated partial pain reduction with BNI score of IIIA-IIIB. Four typical TN patients (18%) had no response to radiosurgery treatment. Of the patients who responded to treatment, actuarial pain recurrence free survival rates were approximately 100%, 75%, and 50% at 12 months, 15 months, and 24 months, respectively. Five atypical TN patients were included, who did not respond to treatment (BNI score: IV-V). However, no radiation-induced cranial-toxicity was observed in all patients treated. CONCLUSION: Linac-based SRS for medically and/or surgically refractory TN is a fast, effective, and safe treatment option for patients with typical TN who had excellent response rates. Patients, who achieve response to treatment, often have durable response rates with moderate actuarial pain recurrence free survival. Longer follow-up interval is anticipated to confirm our clinical observations.


Assuntos
Radiocirurgia/instrumentação , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Neuralgia do Trigêmeo/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor , Avaliação de Resultados da Assistência ao Paciente , Garantia da Qualidade dos Cuidados de Saúde/normas , Dosagem Radioterapêutica , Recidiva , Resultado do Tratamento , Neuralgia do Trigêmeo/patologia
19.
J Clin Neurosci ; 38: 91-95, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28117260

RESUMO

Arteriovenous malformations (AVMs) are the leading causing of intra-cerebral haemorrhage. Stereotactic radiosurgery (SRS) is an established treatment for arteriovenous malformations (AVM) and commonly delivered using Gamma Knife within dedicated radiosurgery units. Linear accelerator (LINAC) SRS is increasingly available however debate remains over whether it offers an equivalent outcome. The aim of this project is to evaluate the outcomes using LINAC SRS for AVMs used within a UK neurosciences unit and review the literature to aid decision making across various SRS platforms. Results have shown comparability across platforms and strongly supports that an adapted LINAC based SRS facility within a dynamic regional neuro-oncology department delivers similar outcomes (in terms of obliteration and toxicity) to any other dedicated radio-surgical platform. Locally available facilities can facilitate discussion between options however throughput will inevitably be lower than centrally based dedicated national radiosurgery units.


Assuntos
Malformações Arteriovenosas Intracranianas/diagnóstico por imagem , Malformações Arteriovenosas Intracranianas/cirurgia , Aceleradores de Partículas , Radiocirurgia/métodos , Adulto , Hemorragia Cerebral/diagnóstico por imagem , Hemorragia Cerebral/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Aceleradores de Partículas/estatística & dados numéricos , Radiocirurgia/instrumentação , Estudos Retrospectivos , Resultado do Tratamento
20.
Radiat Oncol ; 12(1): 7, 2017 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-28069053

RESUMO

BACKGROUND: Modern radiotherapy offers various possibilities for image guided verification of patient positioning. Different clinically relevant IGRT (image guided radiotherapy) scenarios were considered with regard to their influence on dosimetric plan quality and normal tissue complication probability (NTCP). METHODS: This study is based on treatment plans of 50 prostate patients. We evaluate the clinically performed IGRT and simulate the influence of different daily IGRT scenarios on plan quality. Imaging doses of planar and cone-beam-CT (CBCT) images for three different energies (6 MV, 1 MV and 121 kV) were added to the treatment plans. The plan quality of the different scenarios was assessed by a visual inspection of the dose distribution and dose-volume-histogram (DVH) and a statistical analysis of DVH criteria. In addition, an assessment of the normal tissue complication probability was performed. RESULTS: Daily 1MV-CBCTs result in undesirable high dose regions in the target volume. The DVH shows that the scenarios with actual imaging performed, daily kV-CBCT and daily 6MV imaging (1x CBCT, 4x planar images per week) do not differ exceedingly from the original plan; especially imaging with daily kV-CBCT has little influence to the sparing of organs at risk. In contrast, daily 1MV- CBCT entails an additional dose of up to two fraction doses. Due to the additional dose amount some DVH constraints for plan acceptability could no longer be satisfied, especially for the daily 1MV-CBCT scenario. This scenario also shows increased NTCP for the rectum. CONCLUSION: Daily kV-CBCT has negligible influence on plan quality and is commendable for the clinical routine. If no kV-modality is available, a daily IGRT scenario with one CBCT per week and planar axial images on the other days should be preferred over daily MV-CBCT.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Órgãos em Risco/efeitos da radiação , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Radioterapia de Intensidade Modulada/métodos , Humanos , Masculino , Imagens de Fantasmas , Neoplasias da Próstata/diagnóstico por imagem , Radiometria , Dosagem Radioterapêutica , Estudos Retrospectivos