Magn Reson Med ; 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38968093

RESUMO

PURPOSE: T1 mapping and T1-weighted contrasts have a complimentary but currently under utilized role in fetal MRI. Emerging clinical low field scanners are ideally suited for fetal T1 mapping. The advantages are lower T1 values which results in higher efficiency and reduced field inhomogeneities resulting in a decreased requirement for specialist tools. In addition the increased bore size associated with low field scanners provides improved patient comfort and accessibility. This study aims to demonstrate the feasibility of fetal brain T1 mapping at 0.55T. METHODS: An efficient slice-shuffling inversion-recovery echo-planar imaging (EPI)-based T1-mapping and postprocessing was demonstrated for the fetal brain at 0.55T in a cohort of 38 fetal MRI scans. Robustness analysis was performed and placental measurements were taken for validation. RESULTS: High-quality T1 maps allowing the investigation of subregions in the brain were obtained and significant correlation with gestational age was demonstrated for fetal brain T1 maps ( p < 0 . 05 $$ p<0.05 $$ ) as well as regions-of-interest in the deep gray matter and white matter. CONCLUSIONS: Efficient, quantitative T1 mapping in the fetal brain was demonstrated on a clinical 0.55T MRI scanner, providing foundations for both future research and clinical applications including low-field specific T1-weighted acquisitions.

2.
Magn Reson Imaging ; 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38971265

RESUMO

Low field MRI is safer and more cost effective than the high field MRI. One of the inherent problems of low field MRI is its low signal-to-noise ratio or sensitivity. In this work, we introduce a multimodal surface coil technique for signal excitation and reception to improve the RF magnetic field (B1) efficiency and potentially improve MR sensitivity. The proposed multimodal surface coil consists of multiple identical resonators that are electromagnetically coupled to form a multimodal resonator. The field distribution of its lowest frequency mode is suitable for MR imaging applications. The prototype multimodal surface coils are built, and the performance is investigated and validated through numerical simulation, standard RF measurements and tests, and comparison with the conventional surface coil at low fields. Our results show that the B1 efficiency of the multimodal surface coil outperforms that of the conventional surface coil which is known to offer the highest B1 efficiency among all coil categories, i.e., volume coil, half-volume coil and surface coil. In addition, in low-field MRI, the required low-frequency coils often use large value capacitance to achieve the low resonant frequency which makes frequency tuning difficult. The proposed multimodal surface coil can be conveniently tuned to the required low frequency for low-field MRI with significantly reduced capacitance value, demonstrating excellent low-frequency operation capability over the conventional surface coil.

3.
MAGMA ; 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38967865

RESUMO

OBJECTIVE: To propose a deep learning-based low-field mobile MRI strategy for fast, high-quality, unshielded imaging using minimal hardware resources. METHODS: Firstly, we analyze the correlation of EMI signals between the sensing coil and the MRI coil to preliminarily verify the feasibility of active EMI shielding using a single sensing coil. Then, a powerful deep learning EMI elimination model is proposed, which can accurately predict the EMI components in the MRI coil signals using EMI signals from at least one sensing coil. Further, deep learning models with different task objectives (super-resolution and denoising) are strategically stacked for multi-level post-processing to enable fast and high-quality low-field MRI. Finally, extensive phantom and brain experiments were conducted on a home-built 0.2 T mobile brain scanner for the evaluation of the proposed strategy. RESULTS: 20 healthy volunteers were recruited to participate in the experiment. The results show that the proposed strategy enables the 0.2 T scanner to generate images with sufficient anatomical information and diagnostic value under unshielded conditions using a single sensing coil. In particular, the EMI elimination outperforms the state-of-the-art deep learning methods and numerical computation methods. In addition, 2 × super-resolution (DDSRNet) and denoising (SwinIR) techniques enable further improvements in imaging speed and quality. DISCUSSION: The proposed strategy enables low-field mobile MRI scanners to achieve fast, high-quality imaging under unshielded conditions using minimal hardware resources, which has great significance for the widespread deployment of low-field mobile MRI scanners.

4.
Surg Neurol Int ; 15: 218, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38974534

RESUMO

Background: Ultra-low-field magnetic resonance imaging (ULF-MRI) has emerged as an alternative with several portable clinical applications. This review aims to comprehensively explore its applications, potential limitations, technological advancements, and expert recommendations. Methods: A review of the literature was conducted across medical databases to identify relevant studies. Articles on clinical usage of ULF-MRI were included, and data regarding applications, limitations, and advancements were extracted. A total of 25 articles were included for qualitative analysis. Results: The review reveals ULF-MRI efficacy in intensive care settings and intraoperatively. Technological strides are evident through innovative reconstruction techniques and integration with machine learning approaches. Additional advantages include features such as portability, cost-effectiveness, reduced power requirements, and improved patient comfort. However, alongside these strengths, certain limitations of ULF-MRI were identified, including low signal-to-noise ratio, limited resolution and length of scanning sequences, as well as variety and absence of regulatory-approved contrast-enhanced imaging. Recommendations from experts emphasize optimizing imaging quality, including addressing signal-to-noise ratio (SNR) and resolution, decreasing the length of scan time, and expanding point-of-care magnetic resonance imaging availability. Conclusion: This review summarizes the potential of ULF-MRI. The technology's adaptability in intensive care unit settings and its diverse clinical and surgical applications, while accounting for SNR and resolution limitations, highlight its significance, especially in resource-limited settings. Technological advancements, alongside expert recommendations, pave the way for refining and expanding ULF-MRI's utility. However, adequate training is crucial for widespread utilization.

5.
Food Chem ; 458: 140093, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38943960

RESUMO

This study evaluated the effects of postharvest ripening (0-6 days, D0-6) on cell wall pectin profile, infrared-assisted hot air-drying characteristics, and sugar content. Results showed that during postharvest ripening progress, the content of water-soluble pectin (WSP) and chelate-soluble pectin (CSP) increased while the content of Na2CO3-soluble pectin (NSP) and hemicellulose (HC) decreased. In addition, the average molecular weight of WSP increased while the average molecular weight of NSP decreased. Secondly, the drying time of plums with different postharvest ripening periods was in the order: D3 < D4 < D2 < D1 < D0 < D5 < D6. Furthermore, the sugar content of dried plums was mainly influenced by drying time, with three stages of sugar changes observed, tied to moisture content: (1) Sucrose hydrolyzes (50-85%); (2) Fructose and glucose degrade (15-50%); (3) Sorbitol degrades (15-42%). These findings indicate that the transformation of cell wall pectin profile during the postharvest ripening process alters drying behavior and regulates the sugar content of dried plums. CHEMICAL COMPOUNDS STUDIED IN THIS ARTICLE: Galacturonic acid (PubChem CID: 439215); Acetone (PubChem CID: 180); Distilled water (PubChem CID: 962); Trans-1,2-Diaminocyclohexane-N, N, N, N'-tetraacetic acid (PubChem CID: 2723845); Na2CO3 (PubChem CID: 10340); Glucose (PubChem CID: 5793); fructose (PubChem CID: 2723872) sucrose (PubChem CID: 5988) sorbitol (PubChem CID: 5780) and Sodium borohydride (PubChem CID: 4311764).

6.
J Food Sci ; 89(7): 4276-4285, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38837399

RESUMO

Avocado oil is a nutritious, edible oil produced from avocado fruit. It has high commercial value and is increasing in popularity, thus powerful analytical methods are needed to ensure its quality and authenticity. Recent advancements in low-field (LF) NMR spectroscopy allow for collection of high-quality data despite the use of low magnetic fields produced by non-superconductive magnets. Combined with chemometrics, LF NMR opens new opportunities in food analysis using targeted and untargeted approaches. Here, it was used to determine poly-, mono-, and saturated fatty acids in avocado oil. Although direct signal integration of LF NMR spectra was able to determine certain classes of fatty acids, it had several challenges arising from signal overlapping. Thus, we used partial least square regression and developed models with good prediction performance for fatty acid composition, with residual prediction deviation ranging 3.46-5.53 and root mean squared error of prediction CV ranging 0.46-2.48. In addition, LF NMR, combined with unsupervised and supervised methods, enabled the differentiation of avocado oil from other oils, namely, olive oil, soybean oil, canola oil, high oleic (OL) safflower oil, and high OL sunflower oil. This study showed that LF NMR can be used as an efficient alternative for the compositional analysis and authentication of avocado oil. PRACTICAL APPLICATION: Here, we describe the application of LF-NMR for fatty acid analysis and avocado oil authentication. LF-NMR can be an efficient tool for targeted and untargeted analysis, thus becoming an attractive option for companies, regulatory agencies, and quality control laboratories. This tool is especially important for organizations and entities seeking economic, user-friendly, and sustainable analysis solutions.


Assuntos
Ácidos Graxos , Espectroscopia de Ressonância Magnética , Persea , Óleos de Plantas , Persea/química , Espectroscopia de Ressonância Magnética/métodos , Óleos de Plantas/química , Óleos de Plantas/análise , Ácidos Graxos/análise , Quimiometria/métodos , Análise de Alimentos/métodos , Frutas/química
7.
Magn Reson Med ; 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38888139

RESUMO

PURPOSE: To introduce an alternative idea for fat suppression that is suited both for low-field applications where conventional fat-suppression approaches become ineffective due to narrow spectral separation and for applications with strong B0 homogeneities. METHODS: Separation of fat and water is achieved by sweeping the frequency of RF saturation pulses during continuous radial acquisition and calculating frequency-resolved images using regularized iterative reconstruction. Voxel-wise signal-response curves are extracted that reflect tissue's response to RF saturation at different frequencies and allow the classification into fat or water. This information is then utilized to generate water-only composite images. The principle is demonstrated in free-breathing abdominal and neck examinations using stack-of-stars 3D balanced SSFP (bSSFP) and gradient-recalled echo (GRE) sequences at 0.55 and 3T. Moreover, a potential extension toward quantitative fat/water separation is described. RESULTS: Experiments with a proton density fat fraction (PDFF) phantom validated the reliability of fat/water separation using signal-response curves. As demonstrated for abdominal imaging at 0.55T, the approach resulted in more uniform fat suppression without loss of water signal and in improved CSF-to-fat signal ratio. Moreover, the approach provided consistent fat suppression in 3T neck exams where conventional spectrally-selective fat saturation failed due to strong local B0 inhomogeneities. The feasibility of simultaneous fat/water quantification has been demonstrated in a PDFF phantom. CONCLUSION: The proposed principle achieves reliable fat suppression in low-field applications and adapts to high-field applications with strong B0 inhomogeneity. Moreover, the principle potentially provides a basis for developing an alternative approach for PDFF quantification.

8.
Sensors (Basel) ; 24(11)2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38894142

RESUMO

Inline analytics in industrial processes reduce operating costs and production rejection. Dedicated sensors enable inline process monitoring and control tailored to the application of interest. Nuclear Magnetic Resonance is a well-known analytical technique but needs adapting for low-cost, reliable and robust process monitoring. A V-shaped low-field NMR sensor was developed for inline process monitoring and allows non-destructive and non-invasive measurements of materials, for example in a pipe. In this paper, the industrial application is specifically devoted to the quality control of anode slurries in battery production. The characterization of anode slurries was performed with the sensor to determine chemical composition and detect gas inclusions. Additionally, flow properties play an important role in continuous production processes. Therefore, the in- and outflow effects were investigated with the V-shaped NMR sensor as a basis for the future determination of slurry flow fields.

9.
Front Neurol ; 15: 1330203, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38854960

RESUMO

Ultra-low field (ULF) magnetic resonance imaging (MRI) holds the potential to make MRI more accessible, given its cost-effectiveness, reduced power requirements, and portability. However, signal-to-noise ratio (SNR) drops with field strength, necessitating imaging with lower resolution and longer scan times. This study introduces a novel Fourier-based Super Resolution (FouSR) approach, designed to enhance the resolution of ULF MRI images with minimal increase in total scan time. FouSR combines spatial frequencies from two orthogonal ULF images of anisotropic resolution to create an isotropic T2-weighted fluid-attenuated inversion recovery (FLAIR) image. We hypothesized that FouSR could effectively recover information from under-sampled slice directions, thereby improving the delineation of multiple sclerosis (MS) lesions and other significant anatomical features. Importantly, the FouSR algorithm can be implemented on the scanner with changes to the k-space trajectory. Paired ULF (Hyperfine SWOOP, 0.064 tesla) and high field (Siemens, Skyra, 3 Tesla) FLAIR scans were collected on the same day from a phantom and a cohort of 10 participants with MS or suspected MS (6 female; mean ± SD age: 44.1 ± 4.1). ULF scans were acquired along both coronal and axial planes, featuring an in-plane resolution of 1.7 mm × 1.7 mm with a slice thickness of 5 mm. FouSR was evaluated against registered ULF coronal and axial scans, their average (ULF average) and a gold standard SR (ANTs SR). FouSR exhibited higher SNR (47.96 ± 12.6) compared to ULF coronal (36.7 ± 12.2) and higher lesion conspicuity (0.12 ± 0.06) compared to ULF axial (0.13 ± 0.07) but did not exhibit any significant differences contrast-to-noise-ratio (CNR) compared to other methods in patient scans. However, FouSR demonstrated superior image sharpness (0.025 ± 0.0040) compared to all other techniques (ULF coronal 0.021 ± 0.0037, q = 5.9, p-adj. = 0.011; ULF axial 0.018 ± 0.0026, q = 11.1, p-adj. = 0.0001; ULF average 0.019 ± 0.0034, q = 24.2, p-adj. < 0.0001) and higher lesion sharpness (-0.97 ± 0.31) when compared to the ULF average (-1.02 ± 0.37, t(543) = -10.174, p = <0.0001). Average blinded qualitative assessment by three experienced MS neurologists showed no significant difference in WML and sulci or gyri visualization between FouSR and other methods. FouSR can, in principle, be implemented on the scanner to produce clinically useful FLAIR images at higher resolution on the fly, providing a valuable tool for visualizing lesions and other anatomical structures in MS.

10.
Magn Reson Med ; 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38872384

RESUMO

PURPOSE: To develop and validate a highly efficient motion compensated free-breathing isotropic resolution 3D whole-heart joint T1/T2 mapping sequence with anatomical water/fat imaging at 0.55 T. METHODS: The proposed sequence takes advantage of shorter T1 at 0.55 T to acquire three interleaved water/fat volumes with inversion-recovery preparation, no preparation, and T2 preparation, respectively. Image navigators were used to facilitate nonrigid motion-compensated image reconstruction. T1 and T2 maps were jointly calculated by a dictionary matching method. Validations were performed with simulation, phantom, and in vivo experiments on 10 healthy volunteers and 1 patient. The performance of the proposed sequence was compared with conventional 2D mapping sequences including modified Look-Locker inversion recovery and T2-prepared balanced steady-SSFP sequence. RESULTS: The proposed sequence has a good T1 and T2 encoding sensitivity in simulation, and excellent agreement with spin-echo reference T1 and T2 values was observed in a standardized T1/T2 phantom (R2 = 0.99). In vivo experiments provided good-quality co-registered 3D whole-heart T1 and T2 maps with 2-mm isotropic resolution in a short scan time of about 7 min. For healthy volunteers, left-ventricle T1 mean and SD measured by the proposed sequence were both comparable with those of modified Look-Locker inversion recovery (640 ± 35 vs. 630 ± 25 ms [p = 0.44] and 49.9 ± 9.3 vs. 54.4 ± 20.5 ms [p = 0.42]), whereas left-ventricle T2 mean and SD measured by the proposed sequence were both slightly lower than those of T2-prepared balanced SSFP (53.8 ± 5.5 vs. 58.6 ± 3.3 ms [p < 0.01] and 5.2 ± 0.9 vs. 6.1 ± 0.8 ms [p = 0.03]). Myocardial T1 and T2 in the patient measured by the proposed sequence were in good agreement with conventional 2D sequences and late gadolinium enhancement. CONCLUSION: The proposed sequence simultaneously acquires 3D whole-heart T1 and T2 mapping with anatomical water/fat imaging at 0.55 T in a fast and efficient 7-min scan. Further investigation in patients with cardiovascular disease is now warranted.

11.
Sensors (Basel) ; 24(12)2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38931494

RESUMO

Due to limitations in current motion tracking technologies and increasing interest in alternative sensors for motion tracking both inside and outside the MRI system, in this study we share our preliminary experience with three alternative sensors utilizing diverse technologies and interactions with tissue to monitor motion of the body surface, respiratory-related motion of major organs, and non-respiratory motion of deep-seated organs. These consist of (1) a Pilot-Tone RF transmitter combined with deep learning algorithms for tracking liver motion, (2) a single-channel ultrasound transducer with deep learning for monitoring bladder motion, and (3) a 3D Time-of-Flight camera for observing the motion of the anterior torso surface. Additionally, we demonstrate the capability of these sensors to simultaneously capture motion data outside the MRI environment, which is particularly relevant for procedures like radiation therapy, where motion status could be related to previously characterized cyclical anatomical data. Our findings indicate that the ultrasound sensor can track motion in deep-seated organs (bladder) as well as respiratory-related motion. The Time-of-Flight camera offers ease of interpretation and performs well in detecting surface motion (respiration). The Pilot-Tone demonstrates efficacy in tracking bulk respiratory motion and motion of major organs (liver). Simultaneous use of all three sensors could provide complementary motion information outside the MRI bore, providing potential value for motion tracking during position-sensitive treatments such as radiation therapy.


Assuntos
Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Respiração , Fígado/diagnóstico por imagem , Fígado/fisiologia , Movimento/fisiologia , Bexiga Urinária/diagnóstico por imagem , Bexiga Urinária/fisiologia , Algoritmos , Aprendizado Profundo , Movimento (Física) , Ultrassonografia/métodos
13.
Molecules ; 29(9)2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38731577

RESUMO

Recently, benchtop nuclear magnetic resonance (NMR) spectrometers utilizing permanent magnets have emerged as versatile tools with applications across various fields, including food and pharmaceuticals. Their efficacy is further enhanced when coupled with chemometric methods. This study presents an innovative approach to leveraging a compact benchtop NMR spectrometer coupled with chemometrics for screening honey-based food supplements adulterated with active pharmaceutical ingredients. Initially, fifty samples seized by French customs were analyzed using a 60 MHz benchtop spectrometer. The investigation unveiled the presence of tadalafil in 37 samples, sildenafil in 5 samples, and a combination of flibanserin with tadalafil in 1 sample. After conducting comprehensive qualitative and quantitative characterization of the samples, we propose a chemometric workflow to provide an efficient screening of honey samples using the NMR dataset. This pipeline, utilizing partial least squares discriminant analysis (PLS-DA) models, enables the classification of samples as either adulterated or non-adulterated, as well as the identification of the presence of tadalafil or sildenafil. Additionally, PLS regression models are employed to predict the quantitative content of these adulterants. Through blind analysis, this workflow allows for the detection and quantification of adulterants in these honey supplements.


Assuntos
Suplementos Nutricionais , Mel , Espectroscopia de Ressonância Magnética , Mel/análise , Suplementos Nutricionais/análise , Espectroscopia de Ressonância Magnética/métodos , Citrato de Sildenafila/análise , Fluxo de Trabalho , Quimiometria/métodos , Tadalafila/análise , Análise dos Mínimos Quadrados , Contaminação de Medicamentos/prevenção & controle , Análise Discriminante
14.
Magn Reson Med ; 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38725132

RESUMO

PURPOSE: To investigate the feasibility of diffusion tensor brain imaging at 0.55T with comparisons against 3T. METHODS: Diffusion tensor imaging data with 2 mm isotropic resolution was acquired on a cohort of five healthy subjects using both 0.55T and 3T scanners. The signal-to-noise ratio (SNR) of the 0.55T data was improved using a previous SNR-enhancing joint reconstruction method that jointly reconstructs the entire set of diffusion weighted images from k-space using shared-edge constraints. Quantitative diffusion tensor parameters were estimated and compared across field strengths. We also performed a test-retest assessment of repeatability at each field strength. RESULTS: After applying SNR-enhancing joint reconstruction, the diffusion tensor parameters obtained from 0.55T data were strongly correlated ( R 2 ≥ 0 . 70 $$ {R}^2\ge 0.70 $$ ) with those obtained from 3T data. Test-retest analysis showed that SNR-enhancing reconstruction improved the repeatability of the 0.55T diffusion tensor parameters. CONCLUSION: High-resolution in vivo diffusion MRI of the human brain is feasible at 0.55T when appropriate noise-mitigation strategies are applied.

15.
Magn Reson Med ; 92(3): 1011-1021, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38623991

RESUMO

PURPOSE: Demonstrate the potential of spatiotemporal encoding (SPEN) MRI to deliver largely undistorted 2D, 3D, and diffusion weighted images on a 110 mT portable system. METHODS: SPEN's quadratic phase modulation was used to subsample the low-bandwidth dimension of echo planar acquisitions, delivering alias-free images with an enhanced immunity to image distortions in a laboratory-built, low-field, portable MRI system lacking multiple receivers. RESULTS: Healthy brain images with different SPEN time-bandwidth products and subsampling factors were collected. These compared favorably to EPI acquisitions including topup corrections. Robust 3D and diffusion weighted SPEN images of diagnostic value were demonstrated, with 2.5 mm isotropic resolutions achieved in 3 min scans. This performance took advantage of the low specific absorption rate and relative long TEs associated with low-field MRI. CONCLUSION: SPEN MRI provides a robust and advantageous fast acquisition approach to obtain faithful 3D images and DWI data in low-cost, portable, low-field systems without parallel acceleration.


Assuntos
Encéfalo , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Humanos , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Desenho de Equipamento , Reprodutibilidade dos Testes , Algoritmos , Aumento da Imagem/métodos , Sensibilidade e Especificidade , Análise Espaço-Temporal , Processamento de Sinais Assistido por Computador , Imagem Ecoplanar , Análise de Falha de Equipamento , Interpretação de Imagem Assistida por Computador/métodos , Imagem de Difusão por Ressonância Magnética
16.
N Z Vet J ; 72(3): 141-147, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38583873

RESUMO

CASE HISTORY: Medical records from 2009 to 2021 from a private equine referral hospital in Rochester, NH, USA were analysed for cases that underwent general anaesthesia for low-field MRI of the distal limb. These were used to determine peri-anaesthetic morbidity and mortality. CLINICAL FINDINGS AND OUTCOME: Two hundred and forty-three anaesthetic episodes were recorded in horses undergoing low-field MRI. The peri-anaesthetic complication rate prior to discharge was 6.2% (15/243). No patients experienced a fatal complication. Ninety two of the 243 patients had multiple sites imaged, 90/243 received pre-anaesthetic dantrolene, 134/243 received intra-anaesthetic dobutamine, and 15/243 were positioned in dorsal recumbency. Complications included: abdominal discomfort ("colic"; 9/243), myopathy (4/243), hyphaema (1/243) and carpal fracture (1/243). At the time of discharge, 14/15 complications had resolved. Of 135 horses for which data were available 55 became hypotensive during the procedure (lowest mean arterial pressure < 65 mmHg). Median body weight was 553 (min 363, max 771) kg. Horses were anaesthetised for a median of 150 (min 45, max 210) minutes. There was no evidence of an association between higher body weight (p = 0.051) or longer duration of anaesthesia (p = 0.421) and development of an anaesthetic complication. For categorical variables (dantrolene administration pre-anaesthesia, dobutamine administration during anaesthesia, hypotension (mean < 65 mmHg) during anaesthesia, dorsal vs. lateral recumbency, and imaging of single vs. multiple sites), the 95% CI for the OR included 1, indicating a lack of effect of the variable on the odds of complication. CLINICAL RELEVANCE: The cases included in this series suggest that low-field MRI under general anaesthesia is a viable option for diagnostic imaging in otherwise healthy horses. Complications occur, but most resolve before discharge.


Assuntos
Anestésicos , Dobutamina , Cavalos , Animais , Dantroleno , Anestesia Geral/efeitos adversos , Anestesia Geral/veterinária , Imageamento por Ressonância Magnética/veterinária , Peso Corporal
17.
Front Neurol ; 15: 1339223, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38585353

RESUMO

Background: Portable low-field-strength magnetic resonance imaging (MRI) systems represent a promising alternative to traditional high-field-strength systems with the potential to make MR technology available at scale in low-resource settings. However, lower image quality and resolution may limit the research and clinical potential of these devices. We tested two super-resolution methods to enhance image quality in a low-field MR system and compared their correspondence with images acquired from a high-field system in a sample of young people. Methods: T1- and T2-weighted structural MR images were obtained from a low-field (64mT) Hyperfine and high-field (3T) Siemens system in N = 70 individuals (mean age = 20.39 years, range 9-26 years). We tested two super-resolution approaches to improve image correspondence between images acquired at high- and low-field: (1) processing via a convolutional neural network ('SynthSR'), and (2) multi-orientation image averaging. We extracted brain region volumes, cortical thickness, and cortical surface area estimates. We used Pearson correlations to test the correspondence between these measures, and Steiger Z tests to compare the difference in correspondence between standard imaging and super-resolution approaches. Results: Single pairs of T1- and T2-weighted images acquired at low field showed high correspondence to high-field-strength images for estimates of total intracranial volume, surface area cortical volume, subcortical volume, and total brain volume (r range = 0.60-0.88). Correspondence was lower for cerebral white matter volume (r = 0.32, p = 0.007, q = 0.009) and non-significant for mean cortical thickness (r = -0.05, p = 0.664, q = 0.664). Processing images with SynthSR yielded significant improvements in correspondence for total brain volume, white matter volume, total surface area, subcortical volume, cortical volume, and total intracranial volume (r range = 0.85-0.97), with the exception of global mean cortical thickness (r = 0.14). An alternative multi-orientation image averaging approach improved correspondence for cerebral white matter and total brain volume. Processing with SynthSR also significantly improved correspondence across widespread regions for estimates of cortical volume, surface area and subcortical volume, as well as within isolated prefrontal and temporal regions for estimates of cortical thickness. Conclusion: Applying super-resolution approaches to low-field imaging improves regional brain volume and surface area accuracy in young people. Finer-scale brain measurements, such as cortical thickness, remain challenging with the limited resolution of low-field systems.

18.
J Magn Reson ; 362: 107665, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38598992

RESUMO

The NMRduino is a compact, cost-effective, sub-MHz NMR spectrometer that utilizes readily available open-source hardware and software components. One of its aims is to simplify the processes of instrument setup and data acquisition control to make experimental NMR spectroscopy accessible to a broader audience. In this introductory paper, the key features and potential applications of NMRduino are described to highlight its versatility both for research and education.

19.
J Magn Reson ; 362: 107673, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38598990

RESUMO

The rapid advancement of parahydrogen-induced hyperpolarization (PHIP) and its diverse array of applications highlights the critical need for enhanced signals in both 1H NMR and heteronuclear NMR spectroscopy. Simultaneously, there is an increasing interest in utilizing benchtop NMR analysis across various laboratory settings. However, due to their lower magnetic fields, benchtop NMR spectrometers inherently produce weaker signal intensities. Here, PHIP is a well-established solution to this challenge. Consequently, we are expanding our cost-effective PHIP setup from a high-field NMR spectrometer (11.7 T) to include an additional benchtop NMR spectrometer (1.4 T), thereby enabling concurrent execution of PHIP experiments and measurements. Through the implementation of automated experimental protocols, we aim to minimize experiment time while increasing reproducibility. In this work, a non-isotope labelled propargyl alcohol sample is used at low concentrations to demonstrate our setup's capabilities. It could be shown that single-scan PASADENA experiments can be run with comparable signal enhancements at the benchtop as well as the high-field spectrometer. At 1.4 T, fully automated PHIP pseudo-2D measurements will also be demonstrated. Additionally, two different field profiles for the spin-order transfer of p-H2 to 13C at zero- to ultralow fields are elaborated upon. The setup facilitates the measurement of carbon signal enhancement of more than 2000 on the benchtop NMR spectrometer, employing a straightforward one-pulse, one-scan experiment.

20.
J Magn Reson ; 362: 107669, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38598991

RESUMO

MRI systems have a thin conducting layer placed between the gradient and RF coils, this acts as a shield at the RF-frequency, minimizing noise coupled into the experiment, and decreasing the coupling between the RF and gradient coils. Ideally, this layer should be transparent to the gradient fields to reduce eddy currents. In this work the design of such a shield, specifically for low-field point-of-care Halbach based MRI devices, is discussed. A segmented double layer shield is designed and constructed based on eddy current simulations. Subsequently, the performance of the improved shield is compared to a reference shield by measuring the eddy current decay times as well as using noise measurements. A maximum reduction factor of 2.9 in the eddy current decay time is observed. The segmented shield couples in an equivalent amount of noise when compared to the unsegmented reference shield. Turbo spin echo images of a phantom and the brain of a healthy volunteer show improvements in terms of blurring using the segmented shield.