Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 158
Filtrar
1.
Vet Res Commun ; 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38967743

RESUMO

The donkey has always been a notable working animal and its importance as a companion animal has been growing over the last few years. However, there are only a few studies about cardiology in this species. Therefore, this study aimed to evaluate the influence of age, sex, training, and bodyweight on cardiac dimension in mixed-breed donkeys. Forty-five clinically and para-clinically healthy mixed-breed donkeys were included, and B-mode and M-mode echocardiographic measurements were recorded. Multivariate linear regression analysis was performed to identify the effect of age, sex, bodyweight, and training on cardiac measurements. Most of the echocardiographic measurements showed a strong statistically significant correlation with bodyweight. Linear regression analysis between echocardiographic measurements and bodyweight was performed to obtain the values of the intercept and slope of the linear equation to calculate the echocardiographic measurements as a function of bodyweight. This is the first study reporting a strong linear correlation between echocardiographic measurements and bodyweight and reporting a correlation between training and echocardiographic parameters in donkeys, suggesting that this variable should be considered when assessing cardiac dimensions in these animals.

2.
Quant Imaging Med Surg ; 14(6): 4134-4140, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38846297

RESUMO

Background: Omental infarction is a rare pediatric disease. Ultrasound is a useful modality for a non-invasive pre-operative differential diagnosis between inflammatory conditions (as appendicitis) and omental infarction, especially by detecting immobility of the omentum adhered to the abdominal wall ("tetherd fat sign"). However, this is a dynamic sign that cannot be documented in a static image with B-mode technique. The goal of this work is to incorporate the versatile function of motion mode (M-mode) into omental infarction diagnosis to describe how the M-mode is useful in the evaluation of fat motion in children suspected of having omental infarction. In 2019 we suggested a new Ultrasound sign named "tethered fat sign" for an accurate non-invasive diagnosis of omental infarction in children. This finding was observed in 6 of the 234 seen children of our previous study with 4 laparoscopic confirmed diagnosis. Methods: From January 2019 to July 2021, we evaluated 195 children (91 boys and 104 girls, from 3 to 15 years) admitted to our Santobono-Pausilipon Children Hospital with acute right-sided abdominal pain. Abdominal ultrasound was performed to all the patients and the investigation of "tethered fat sign" was always included. Results: In 7 patients ultrasound showed the presence of a hyperechoic oval mass localized in the right upper abdominal quadrant and in 2 of these M-mode documented a normal subhepatic fat moving during respiratory movements in relation with the abdominal wall. The remaining 5 patients had an omental infarction showed as a subhepatic motionless mass tethered to the abdominal wall on M-mode. In these patients, a sonographic follow-up was performed every 15 d for 2 months showing a progressive reduction in size of the right-sided hyperechoic mass. Conclusions: In the evaluation of all children who showed the presence of the "tethered fat sign" the use of M-mode provide a certified image in diagnostic ultrasound.

3.
Curr Med Imaging ; 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38918981

RESUMO

BACKGROUND: Patient safety is paramount in ultrasound procedures, particularly in obstetric ultrasounds involving both the mother and fetus. The thermal and mechanical indices (TI and MI) serve as crucial indicators of the acoustic output during ultrasound. Clinicians and specialists must know these indices and ensure they are within safe ranges. This study aimed to assess the parameters of acoustic output power employed in obstetric ultrasound (thermal and mechanical index). METHODOLOGY: A cross-sectional observational study conducted at Maternity and Children's Hospital in Al-Madina Al-Munawwarah, the data was collected from obstetric scanning of 411 pregnant females using a data collection sheet including gravida and women's age, gestational age, scan mode, scan time, and thermal and mechanical index (TI and MI) values. RESULTS: The study found that there were significant differences in safety indices measurement between different modes; in Pulsed Doppler, mean Thermal Index Bone (TIb) had the highest value (1.60±0.40), and the Mechanical Index (MI) was the lowest (0.68±0.33). There were insignificant differences in safety indices values in different modes in different trimesters. The thermal indices of soft tissue and bony structure (TIs and TIb) of brightness mode (B-mode) were constant in all trimesters, but the MI in the first trimester was lower than in the other trimesters. CONCLUSION: This study found significant differences in TIs, TIb, and MI in different modes of obstetric ultrasound. Pulsed Doppler ultrasonography had the highest TIb value and a lower MI value. The ultrasound acoustic exposure output parameters were within the standard's recommended limit.

4.
Cureus ; 16(4): e57563, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38707132

RESUMO

INTRODUCTION: This study aimed to evaluate the asymmetry in the lateral abdominal muscles (LAMs) expressed as tissue deformation index asymmetry (aTDI) with the use of M-mode ultrasonography. The muscles of interest were the transversus abdominis, internal oblique, and external oblique. METHODS: This is a cohort of 126 healthy subjects who participated in the study. Measurements were taken by two raters, blinded to the aim of the study. M-mode ultrasounds with a measurement frequency of 5 MHz were utilized to record the postural response of LAMs to external perturbation in the form of rapid arm abduction with load, and individual aTDI values for each muscle were calculated. RESULTS: The aTDI values from deep to superficial LAMs were 78.28% for transversus abdominis, 55.68% for internal oblique, and 44.80% for external oblique. Only the aTDI for transversus abdominis results differed significantly from those of the other LAMs (P<0.05). CONCLUSION: LAM asymmetry values exhibit the following gradient: transversus abdominis >internal oblique >external oblique. Specifically, only transversus abdominis demonstrates noteworthy asymmetry in postural activity. This observation contributes to the literature by indicating that transversus abdominis asymmetry may serve as a marker for assessing the variability in motor control of the deep abdominal musculature. The dominance of transversus abdominis (TrA) asymmetric activity underlines the importance of personalized approaches for patients with lumbopelvic disorders or for athletes seeking to enhance performance.

5.
Int J Cardiovasc Imaging ; 40(6): 1245-1256, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38652399

RESUMO

To enhance M-mode echocardiography's utility for measuring cardiac structures, we developed and evaluated an artificial intelligence (AI)-based automated analysis system for M-mode images through the aorta and left atrium [M-mode (Ao-LA)], and through the left ventricle [M-mode (LV)]. Our system, integrating two deep neural networks (DNN) for view classification and image segmentation, alongside an auto-measurement algorithm, was developed using 5,958 M-mode images [3,258 M-mode (LA-Ao), and 2,700 M-mode (LV)] drawn from a nationwide echocardiographic dataset collated from five tertiary hospitals. The performance of view classification and segmentation DNNs were evaluated on 594 M-mode images, while automatic measurement accuracy was tested on separate internal test set with 100 M-mode images as well as external test set with 280 images (140 sinus rhythm and 140 atrial fibrillation). Performance evaluation showed the view classification DNN's overall accuracy of 99.8% and segmentation DNN's Dice similarity coefficient of 94.3%. Within the internal test set, all automated measurements, including LA, Ao, and LV wall and cavity, resonated strongly with expert evaluations, exhibiting Pearson's correlation coefficients (PCCs) of 0.81-0.99. This performance persisted in the external test set for both sinus rhythm (PCC, 0.84-0.98) and atrial fibrillation (PCC, 0.70-0.97). Notably, automatic measurements, consistently offering multi-cardiac cycle readings, showcased a stronger correlation with the averaged multi-cycle manual measurements than with those of a single representative cycle. Our AI-based system for automatic M-mode echocardiographic analysis demonstrated excellent accuracy, reproducibility, and speed. This automated approach has the potential to improve efficiency and reduce variability in clinical practice.


Assuntos
Automação , Ecocardiografia , Interpretação de Imagem Assistida por Computador , Valor Preditivo dos Testes , Humanos , Reprodutibilidade dos Testes , Bases de Dados Factuais , Aprendizado Profundo , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Feminino , Masculino , Variações Dependentes do Observador , Pessoa de Meia-Idade , Idoso , Conjuntos de Dados como Assunto , Inteligência Artificial , Aorta/diagnóstico por imagem
6.
Artigo em Inglês | MEDLINE | ID: mdl-38477161

RESUMO

OBJECTIVES: During human pregnancy placental extravillous trophoblasts replace the vascular smooth muscle and elastic tissue within the walls of the uterine spiral arteries, thereby remodeling these arteries into distensible low resistance vessels to promote placental perfusion. The present study, determined whether B-flow/ spatio-temporal image correlation (STIC) M-mode ultrasonography provides an in vivo imaging method to digitally quantify spiral artery luminal distensibility, as a physiological index of spiral artery remodeling, during advancing stages of normal human pregnancy. METHODS: A prospective longitudinal observational study was conducted to quantify spiral artery distensibility, i.e. vessel luminal diameter at systole minus diameter at diastole, by B-flow/STIC M-mode ultrasonography during the first, second and third trimesters in 290 women exhibiting normal pregnancy. Maternal serum levels of placental growth factor (PlGF) and soluble fms-like tyrosine kinase (sFlt-1), growth factors that modulate events important in spiral artery remodeling, were quantified in a subset of the subjects at the first, second and third semesters. RESULTS: Median [first quartile, third quartile] spiral artery distensibility progressively increased (P < 0.0001) between the first trimester (0.17 [0.14, 0.21]), second (0.23 [0.18, 0.28]) and third (0.26 [0.21, 0.35]) trimesters of pregnancy. Spiral artery volume flow (ml/cardiac cycle) progressively increased (P < 0.001) between the first 2.49 [1.38, 4.99], second 3.86 [2.06, 6.91] and third 7.79 [3.83, 14.98] trimesters. Coinciding with the elevation in spiral artery distensibility, the median ratio of serum PlGF/sFlt-1 levels increased (P < 0.001) between the first (7.2 [4.5, 10], second (22.7 [18.6, 42.2]) and third (56.2 [41.9, 92.5] trimesters. CONCLUSIONS: The present study shows that B-flow/STIC M-mode ultrasonography provides an in vivo imaging technology to digitally quantify structural/physiological expansion of the walls of the spiral arteries during the cardiac cycle as a consequence of their transformation into compliant vessels during advancing stages of normal human pregnancy. This article is protected by copyright. All rights reserved.

7.
Artigo em Inglês | MEDLINE | ID: mdl-38477180

RESUMO

OBJECTIVE: To compare the fetal cardiac functions between pregnant women with iron deficiency anemia (IDA) and healthy controls. METHODS: This single-center, prospective, case-control study was conducted at a tertiary hospital. A total of 150 patients, including 50 patients with IDA and 100 healthy pregnant women at 30-34 weeks of gestation, were included in the study. Of the patients with anemia, 20 had mild anemia, 18 had moderate anemia, and 12 had severe anemia. Pulsed-wave Doppler, M-mode, and tissue Doppler imaging (TDI) were performed to evaluate fetal cardiac functions. The fetal cardiac score was calculated using the systolic, diastolic, and global hemodynamic function parameters. RESULTS: The myocardial performance index and isovolumetric relaxation time were significantly higher in the IDA group than the control group, while isovolumetric contraction time was similar. Among the tricuspid and mitral valve diastolic parameters, the E, A, and E/A values were significantly lower in the IDA group (p<0.001). Mitral and tricuspid annular plane systolic excursions (MAPSE and TAPSE, respectively) were significantly lower in the IDA group (p<0.001). The IDA group also had significantly lower values for the TDI parameters, mitral and tricuspid E', A', S', E'/A' and a significantly higher E/E' ratio (p<0.001). Upon examination of anemia subgroups, a significant decrease was observed in the tricuspid and mitral A, E, and E/A in those with severe anemia (p<0.001). M-mode Doppler analysis revealed significantly lower TAPSE and MAPSE in the patient group with severe anemia. According to the subgroup comparison of TDI findings, the patients with severe anemia had significantly lower tricuspid and mitral E', A', S' and E'/A' (p<0.001) values and a significantly higher E/E' ratio (p<0.001). The fetal cardiac score was significantly higher in the maternal IDA group compared to the control group. A significant negative correlation was found between maternal hemoglobin level and fetal cardiac score (p<0.001). CONCLUSIONS: There may be changes in the systolic and diastolic cardiac functions of the fetuses of pregnant women with IDA. This study showed an increased E/E' ratio in the fetuses of pregnant women with IDA, suggesting a decrease in fetal heart maturation. Within the IDA group, fetal cardiac functions were more affected in those with severe anemia. This article is protected by copyright. All rights reserved.

8.
Quant Imaging Med Surg ; 14(1): 123-135, 2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38223084

RESUMO

Background: Lung ultrasound (LUS) and diaphragm ultrasound (DUS) are the appropriate modalities for conservative observation to those patients who are with stable pneumothorax, as well as for the timely detection of life-threatening pneumothorax at any location, due to they are portable, real-time, relatively cost effective, and most important, without radiation exposure. The absence of lung sliding on LUS M-mode images and the abnormality of diaphragmatic excursion (DE) on DUS M-mode images are the most common and novel diagnostic criteria for pneumothorax, respectively. However, visual inspection of M-mode images remains subjective and quantitative analysis of LUS and DUS M-mode images are required. Methods: Shannon entropy of LUS M-mode image (ShanEnLM) and DE based on the automated measurement (DEAM) are adapted to the objective pneumothorax diagnoses and the severity quantifications in this study. Mild, moderate, and severe pneumothoraces were induced in 24 male New Zealand rabbits through insufflation of room air (5, 10 and 15, and 25 and 40 mL/kg, respectively) into their pleural cavities. In vivo intercostal LUS and subcostal DUS M-mode images were acquired using a point-of-care system for estimating ShanEnLM and DEAM. Results: ShanEnLM and DEAM as functions of air insufflation volumes exhibited U-shaped curves and were exponentially decreasing, respectively. Either ShanEnLM or DEAM had areas under the receiver operating characteristic curves [95% confidence interval (CI)] of 1.0000 (95% CI: 1.0000-1.0000), 0.9833 (95% CI: 0.9214-1.0000), and 0.9407 (95% CI: 0.8511-1.0000) for differentiating between normal and mild pneumothorax, mild and moderate pneumothoraces, and moderate and severe pneumothoraces, respectively. Conclusions: Our findings imply that the combination of ShanEnLM and DEAM give the promising potential for pneumothorax quantitative diagnosis.

9.
J Perinat Med ; 52(2): 239-245, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-37853744

RESUMO

OBJECTIVES: To demonstrate possible functional changes in the frequently affected fetal interventricular septum (IVS) with spectral tissue Doppler imaging (TDI) and M-mode imaging to compare gestational diabetes mellitus (GDM) and control groups. METHODS: A total of 63 pregnant women with GDM, 30 on diet (A1 GDM) and 33 on treated with insulin (A2 GDM), and 63 healthy pregnant women randomly selected and matched to the case group in the control group were included. RESULTS: The GDM fetuses had significantly thickened IVS, increased early diastole (E'), atrial contraction (A'), systole (S'), higher myocardial performance index (MPI'), prolonged isovolumetric relaxation time (IVRT'), shortened ejection time (ET'), and decreased septal annular plane systolic excursion (SAPSE) than the controls. The A2 GDM group fetuses had significantly thickened IVS, increased S' and shortened ET' than the A1 GDM group. In the GDM group, we found a significantly positive low correlation between glycated hemoglobin levels and maternal serum fasting glucose and one-hour postprandial glucose with fetal IVS thickness. We demonstrated a significantly negative low correlation between maternal serum one-hour postprandial glucose, glycated hemoglobin levels, and gestational weight gain with fetal IVS ET'. CONCLUSIONS: Fetal IVS diastolic and systolic functions were altered in the GDM group compared to controls, and systolic functions were altered in A2 GDM compared to A1 GDM. This may alert clinicians to possible cardiovascular diseases in the postnatal life, and early preventive strategies and long-term lifestyle changes may provide protection in fetuses with GDM.


Assuntos
Diabetes Gestacional , Gravidez , Feminino , Humanos , Diabetes Gestacional/diagnóstico por imagem , Estudos de Casos e Controles , Hemoglobinas Glicadas , Feto , Glucose , Coração Fetal/diagnóstico por imagem
10.
J Cardiothorac Vasc Anesth ; 38(1): 123-132, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37845143

RESUMO

OBJECTIVES: To compare transesophageal echocardiography-guided 2-dimensional and M-mode tricuspid annular plane systolic excursion (TAPSE) to transthoracic echocardiography (TTE)-guided M-mode TAPSE in terms of accuracy, interobserver, and intra-observer variability. DESIGN: A prospective, observational study. SETTING: Adult and pediatric operating rooms. PARTICIPANTS: Adult and pediatric patients (42 each) undergoing cardiac surgeries. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Modified midesophageal (Mod-ME), deep transgastric, and transgastric TAPSEs were analyzed for reliability and were compared to TTE TAPSE in both adult and pediatric groups. Modified ME TAPSE showed good method agreement with TTE TAPSE (bias = -0.97, p = 0.08 (adult); bias = 0.17, p = 0.71 [pediatric]), and showed a moderate correlation with right ventricular (RV) fractional area change (FAC) (r = 0.41, p = 0.006, [adult]; r = 0.57, p < 0.001, [pediatric]), with acceptable interobserver variability (percentage error =10.56 [adult]; 4.42 [pediatric]) and intraobserver variability (percentage error = 13.1 [adults]; 12.24 [pediatric]). Transgastric TAPSE poorly agreed with TTE TAPSE and had higher interobserver and intraobserver variability. Deep transgastric TAPSE had good method agreement with TTE TAPSE and had acceptable interobserver and intra-observer variability. CONCLUSIONS: Modified ME TAPSE is a reliable and reproducible measure of RV function before pericardiotomy in both adult and pediatric cardiac surgery. Right ventricular FAC values reflected the RV systolic function better than TAPSE after pericardiotomy. Deep transgastric TAPSE is reliable and reproducible but is less accurate than Mod-ME TAPSE.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Disfunção Ventricular Direita , Adulto , Humanos , Criança , Ecocardiografia Transesofagiana/métodos , Estudos Prospectivos , Função Ventricular Direita , Reprodutibilidade dos Testes , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Ecocardiografia
11.
J Ultrasound Med ; 43(1): 85-94, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37772464

RESUMO

OBJECTIVE: To compare the cardiac functions of fetuses with preterm premature rupture of membranes (PPROM) between their control groups and investigate its relationship with perinatal outcomes. METHODS: This prospective study was conducted with 102 pregnant women. Pregnant women with PPROM were divided into two subgroups Group A, between 26 and 30 weeks, and Group B, between 30 and 34 weeks. A control group was formed by randomly including one healthy pregnant woman for each study patient. Sociodemographic, obstetric data, tissue Doppler imaging, and M-mode imaging results were compared. The relationship between echocardiographic parameters and perinatal outcomes was also investigated. RESULTS: Tricuspid annular plane systolic excursion (TAPSE), S', and ET' of systolic cardiac parameters were shortened in both groups compared with their controls. Diastolic function indicator E'/A', and global function indicator myocardial performance index' increased in both groups. Isovolumetric contraction time' did not change between groups. A correlation was found between myocardial performance index', and the length of neonatal intensive care unit stay in Group A and TAPSE and duration of respiratory support and length of neonatal intensive care unit stay in Group B. CONCLUSIONS: The fetal cardiac function seems to be affected by PPROM, and these changes are associated with neonatal outcomes. Therefore, administering fetal cardiac function evaluation in pregnancies complicated by PPROM may help physicians establish more appropriate clinical management protocols in this special population.


Assuntos
Ruptura Prematura de Membranas Fetais , Nascimento Prematuro , Recém-Nascido , Humanos , Feminino , Gravidez , Estudos de Casos e Controles , Estudos Prospectivos , Feto , Ruptura Prematura de Membranas Fetais/diagnóstico por imagem , Ultrassonografia Doppler
12.
IEEE J Transl Eng Health Med ; 12: 119-128, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38088993

RESUMO

The objective of this study was to develop an interpretable system that could detect specific lung features in neonates. A challenging aspect of this work was that normal lungs showed the same visual features (as that of Pneumothorax (PTX)). M-mode is typically necessary to differentiate between the two cases, but its generation in clinics is time-consuming and requires expertise for interpretation, which remains limited. Therefore, our system automates M-mode generation by extracting Regions of Interest (ROIs) without human in the loop. Object detection models such as faster Region Based Convolutional Neural Network (fRCNN) and RetinaNet models were employed to detect seven common Lung Ultrasound (LUS) features. fRCNN predictions were then stored and further used to generate M-modes. Beyond static feature extraction, we used a Hough transform based statistical method to detect "lung sliding" in these M-modes. Results showed that fRCNN achieved a greater mean Average Precision (mAP) of 86.57% (Intersection-over-Union (IoU) = 0.2) than RetinaNet, which only displayed a mAP of 61.15%. The calculated accuracy for the generated RoIs was 97.59% for Normal videos and 96.37% for PTX videos. Using this system, we successfully classified 5 PTX and 6 Normal video cases with 100% accuracy. Automating the process of detecting seven prominent LUS features addresses the time-consuming manual evaluation of Lung ultrasound in a fast paced environment. Clinical impact: Our research work provides a significant clinical impact as it provides a more accurate and efficient method for diagnosing lung diseases in neonates.


Assuntos
Pneumonia , Pneumotórax , Humanos , Recém-Nascido , Pulmão/diagnóstico por imagem , Redes Neurais de Computação , Pneumotórax/diagnóstico por imagem , Tórax
13.
BMC Sports Sci Med Rehabil ; 15(1): 112, 2023 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-37715283

RESUMO

BACKGROUND: Abdominal bracing is a maneuver widely used by rehabilitation specialists and sports trainers to improve spinal stability. This study aimed to investigate how lifting tasks with and without abdominal bracing affect the respiratory function of the diaphragm. METHODS: M-mode ultrasonographic assessment of diaphragmatic motion combined with spirometry was performed on 31 healthy adults. Participants were asked to breathe continuously whilst lifting a load with spontaneous abdominal muscle contraction (natural loaded breathing) and abdominal bracing (AB loaded breathing). RESULTS: Pearson's correlations revealed strong correlations between ultrasonography and spirometry measures (p < 0.001) for all types of breathing: tidal breathing (r = 0.709, r2 = 0.503), natural loaded breathing (r = 0.731, r2 = 0.534) and AB loaded breathing (r = 0.795, r2 = 0.632). Using paired-samples t-tests, the natural loaded breathing ultrasonography revealed more caudal diaphragm positions during inspiration (p < 0.001) but not during expiration (p = .101). Spirometry demonstrated lower lung volumes (L) at the end of inspiration and expiration (p < 0.001), with no changes in total lung volume (p = 0.06). The AB loaded breathing ultrasonography revealed more caudal diaphragm positions during inspiration (p = 0.002) but not during expiration (p = 0.05). Spirometry demonstrated lower lung volumes at the end of inspiration (p < 0.001), expiration (p = 0.002), and total lung volumes (p = 0.019). CONCLUSION: This study demonstrated that abdominal bracing performed during a lifting task reduces lung volume despite an increase in diaphragmatic motion. Diaphragm excursions strongly correlate with lung volumes even under postural loading. TRIAL REGISTRATION: The study was prospectively registered on 8 April 2021 at ClinicalTrials.gov with identification number NCT04841109.

14.
Animals (Basel) ; 13(18)2023 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-37760386

RESUMO

This review article focuses on the use of canine M-mode in veterinary medicine, specifically in assessing the left ventricle measurements in several breeds. It traces the historical development of echocardiography techniques, including A-mode, B-mode, and motion mode (M-mode), which provide accurate unidimensional records of cardiac structures. This article highlights the significance of M-mode measurements in diagnosing stage B2 of MMVD, where left ventricular end-diastolic internal diameter corrected with body weight (LVIDdN) is essential for identifying cardiac enlargement. It also explains the role of M-mode in diagnosing DCM, outlining criteria such as left ventricular dilatation. The authors emphasize the importance of breed-specific reference values for echocardiographic measurements due to variations in somatotype among dogs. This review provides a comprehensive table summarizing M-mode measurements of the left ventricle for 44 different dog breeds, including interventricular septum thickness, left ventricular internal diameter, and left ventricular posterior wall thickness during systole and diastole. This review's methodology involves compiling data from various scientific literature sources, providing an extensive tabular representation of M-mode measurements for different breeds, ages, and sexes. Overall, this review highlights the critical role of M-mode echocardiography in diagnosing and managing cardiac diseases in dogs, underscores the importance of breed-specific reference values, and presents a comprehensive summary of M-mode measurements for various dog breeds, aiding both clinicians and researchers.

15.
Ultrasound Med Biol ; 49(12): 2557-2564, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37749012

RESUMO

OBJECTIVE: During early human pregnancy, placental trophoblasts remodel spiral arteries into distensible low-resistance vessels to promote placental perfusion. We have established a model of impaired spiral artery remodeling (SAR) by elevating estradiol levels in the first trimester of baboon pregnancy. In the present study, B-flow/spatiotemporal image correlation (STIC) M-mode ultrasonography, a non-Doppler technology for sharp rendering of vessel dimensions, was used to determine whether spiral artery distensibility was altered in SAR-suppressed baboons. Contrast-enhanced ultrasound/microbubble imaging was also performed to determine whether it detected changes in placenta intervillous space perfusion in SAR-suppressed baboons. METHODS: The two imaging procedures were performed in the first trimester in baboons not treated or treated with estradiol to suppress SAR. RESULTS: Spiral artery distensibility, that is, luminal diameter at systole minus diameter at diastole, and volume flow as quantified by B-flow/STIC M-mode were 26% (p = 0.03) and 55% (p = 0.059) lower, respectively, in SAR-suppressed baboons. However, placental intervillous space flow rate and video intensity plateau levels reflecting blood perfusion, quantified by contrast-enhanced ultrasound/microbubble imaging, were unaltered in SAR-suppressed baboons. CONCLUSION: The results indicate that B-flow/STIC M-mode ultrasonography provides a non-invasive method to detect reduced distensibility and, thus, function of spiral arteries across the cardiac cycle in the first trimester in a primate model of impaired SAR. This study represents a first step in determining whether B-flow/STIC M-mode detects a similar defect in SAR early in adverse human pregnancy. This would provide an avenue to develop therapeutic modalities to prevent the devastating consequences of impaired SAR.


Assuntos
Microbolhas , Placenta , Animais , Gravidez , Feminino , Humanos , Placenta/diagnóstico por imagem , Placenta/irrigação sanguínea , Primeiro Trimestre da Gravidez , Artérias/diagnóstico por imagem , Estradiol , Ultrassonografia , Papio , Perfusão
16.
Animals (Basel) ; 13(15)2023 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-37570261

RESUMO

The assessment of diastolic function has received great interest in order to comprehend its crucial role in the pathophysiology of heart failure and for the early identification of cardiac events. Silent changes in the intraventricular flow (IVF) dynamics occur before the deterioration of the cardiac wall, although they cannot be detected using conventional echocardiography. Collective information on left ventricular (LV) pressures throughout the cardiac cycle has great value when dealing with patients with altered hemodynamics. Accurate pressure measurement inside the ventricle can be obtained by invasive methods to determine the LV diastolic pressures, which reflect the myocardial relaxation and compliance. However, catheterization is only feasible in the laboratory setting and is not suitable for clinical use due to its disadvantages. In contrast, echocardiography is simple, safe, and accessible. Color M-mode echocardiography (CMME) is an advanced cardiac evaluation technique that can measure the intraventricular pressure differences (IVPDs) and intraventricular pressure gradients (IVPGs) based on the Doppler shift of the IVF. Recently, the assessment of IVPD and IVPG has gained growing interest in the cardiovascular literature in both animal and human studies as a non-invasive method for the early diagnosis of cardiac dysfunctions, especially diastolic ones. The usability of IVPD and IVPG has been reported in various surgically induced heart failure or pharmacologically altered cardiac functions in rats, dogs, cats, and goats. This report aims to give an overview of the current studies of CMME-derived IVPD and IVPG in animal studies and its feasibility for clinical application in veterinary practice and to provide the prospects of the technique's ability to improve our understanding.

17.
Echocardiography ; 40(8): 822-830, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37458597

RESUMO

OBJECTIVE: To determine whether changes in fetal heart function according to glycemic control in pregnant women with Type 1 and Type 2 diabetes using spectral tissue Doppler imaging (TDI) and M-mode imaging. METHODS: This study included 68 pregestational diabetic women (DM) at 30-32 gestational weeks. All participants were divided into two groups: type 1(n = 17) and type 2(n = 51), and then these groups were divided into the subgroups as well-controlled and poorly controlled, according to fasting glucose (FG) and 1-h postprandial glucose (PPG) values. Cardiac parameters were compared for well- and poorly-controlled groups with TDI and M-mode imaging. The correlation of cardiac parameters with FG, PPG, and HbA1c values was evaluated. Their roles in predicting neonatal outcomes were also assessed. RESULTS: Thickness measurements, early diastolic annular peak velocity (E'), late diastolic annular peak velocity (A'), tissue isovolumetric relaxation time (IRT'), and tissue myocardial performance index (MPI') were increased in both poorly controlled groups. Tissue ejection time (ET') was significantly reduced in the poorly controlled groups, while tissue isovolumetric contraction time (ICT') was not significantly changed in any group. Tricuspid, mitral, and septal annular plane excursions (TAPSE, MAPSE, and SAPSE, respectively) were significantly decreased in all poorly controlled subgroups. E', E'/A', MPI', IRT', ET', and M-mode imaging parameters significantly correlated with FG notably. CONCLUSION: Maternal hyperglycemia leads to subtle changes in systolic and diastolic functions both in the interventricular septum and ventricles, so it is essential to ensure glycemic control in both Type 1 and Type 2 DM.


Assuntos
Diabetes Mellitus Tipo 2 , Recém-Nascido , Feminino , Humanos , Gravidez , Diabetes Mellitus Tipo 2/complicações , Controle Glicêmico , Estudos Prospectivos , Coração Fetal/diagnóstico por imagem , Glucose
18.
Clin Physiol Funct Imaging ; 43(6): 453-462, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37395325

RESUMO

The study examines global and regional systolic shortening of the left (LV) and right ventricle (RV) in 1266 individuals without evidence of heart disease in the third wave of the HUNT study. Regional mitral annular systolic displacement (mitral annular plane systolic excursion [MAPSE]) was 1.5 cm in the septum and anterior walls, 1.6 cm in the lateral wall and 1.7 cm in the inferior wall, global mean 1.6 cm. Peak systolic velocity S' was 8.0, 8.3, 8.8 and 8.6 cm/s in the same walls (global mean 8.7 cm/s). All measures of LV longitudinal shortening correlated, mean MAPSE and S' also correlated with stroke volume (SV) and ejection fraction (EF). Global longitudinal strain by either method correlated with MAPSE, S' and EF, but not with SV, reflecting a systematic difference. S' and MAPSE correlated with early annular diastolic velocity (e'), reflecting that e' is the recoil from systole. Mean displacement was 2.8 (0.5) cm in the tricuspid annulus (tricuspid annular plane systolic excursion [TAPSE]). Normal values by age and sex are provided. Both TAPSE and S' were lower in women, where body size explained the sex difference. Normalisation of MAPSE and S' for wall length reduced intra-individual variation of displacement and velocity by 80%-90%, showing regional MAPSE to be related to LV wall length, and that longitudinal wall strain was relatively uniform. Displacement and S' were lowest in the septum and highest in the left and right free walls, shows systolic bending of the AV-plane into a U-shape, relating to the total cardiac volume changes during the heart cycle.


Assuntos
Cardiopatias , Disfunção Ventricular Esquerda , Humanos , Masculino , Feminino , Volume Sistólico , Valva Mitral/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem
19.
Math Biosci Eng ; 20(4): 6721-6734, 2023 02 03.
Artigo em Inglês | MEDLINE | ID: mdl-37161125

RESUMO

The original diameter velocity loop method (ln(D)U-loop) cannot accurately extract the blood vessel diameter waveform when the quality of ultrasound image data is not high (such as obesity, age, and the operation of the ultrasound doctor), so it is unable to measure the pulse wave velocity (PWV) of the ascending aorta. This study proposes a diameter waveform extraction method combining threshold, gradient filtering, and the center of gravity method. At the same time, the linear regression method of searching for the rising point of the systolic period is replaced by the optimal average of two linear regression methods. This method can also extract the diameter waveform with poor-quality images and obtain a more accurate PWV. In vivo experimental data from 17 (age 60.5 ± 9.2) elderly patients with cerebral infarction and 12 (age 32.5 ± 5.6) healthy young adults were used for processing, and the results showed that the mean PWV using the ln(D)U-loop method was 12.56 (SD = 3.47) ms-1 for patients with cerebral infarction and 6.81 (SD = 1.73) ms-1 for healthy young adults. The PWV results based on the Wilcoxon rank-sum test and calculated based on the improved ln(D)U-loop method were both statistically significant (p < 0.01). The agreement analysis (Bland-Altman analysis) between the QA-loop and ln(D)U-loop methods showed that the mean deviation of the measured PWV was 0.07 m/s and the standard deviation of the deviation was 1.18 m/s. The experimental results demonstrated the effectiveness of the improved ln(D)U-loop method proposed in this paper on poor-quality images. This study can improve the possibility of the ln(D)U-loop method being widely used in the clinical measurement of ascending aortic PWV.


Assuntos
Aorta , Análise de Onda de Pulso , Idoso , Adulto Jovem , Humanos , Pessoa de Meia-Idade , Adulto , Aorta/diagnóstico por imagem , Infarto Cerebral , Nível de Saúde , Processamento de Imagem Assistida por Computador
20.
Front Cardiovasc Med ; 10: 1059713, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36937909

RESUMO

Background: Over the past decades, assisted reproductive technologies (ART) have gained remarkable influence in the treatment of infertility and account for more than 2 % of births in European countries nowadays. Accumulating evidence suggests ART to cause cardiovascular alterations, including left ventricular (LV) dysfunctions, within its offspring. The aim of this study was to assess LV systolic function in subjects conceived through ART in comparison to spontaneously conceived peers. Methods: For the assessment of LV morphology and LV function, M-Mode echocardiography, pulsed wave Doppler and two-dimensional speckle tracking echocardiography (2DSTE) were applied. LV ejection fraction (EF) and fractional shortening (FS) were assessed in M-Mode and calculated by Teichholz formula. EF was additionally assessed semiautomatically through 2DSTE. Results: In total, 64 ART subjects and 83 spontaneously conceived controls with no significant differences in age (12.52 ± 5.64 years vs. 13.20 ± 5.95 years, p = 0.486) and sex were included in the analysis. In the ART cohort, significantly lower values were observed for M-Mode assessed EF (63.63 ± 5.17 % vs. 65.35 ± 5.10 %, p = 0.046) and FS (34.26 ± 3.87 % vs. 35.60 ± 3.84 %, p = 0.038). However, after the adjustment for birth weight percentile and gestational age, M-Mode assessed EF and FS displayed no significant differences between both groups. LV morphology and remaining systolic function parameters, such as mitral annular plane systolic excursion, aortic velocity time integral, global peak longitudinal strain and 2DSTE measured EF, were comparable between both groups. Conclusion: This study suggests a lower LV systolic function in ART subjects, visualized by significantly lower values for M-Mode assessed EF and FS, compared to spontaneously conceived peers. The clinical relevance of these findings has to be investigated as the above-mentioned parameters were in normal reference range. In addition, LV systolic function parameters evaluated by other echocardiographic imaging modalities were comparable between both groups. Therefore, further studies will be required to evaluate the influence of ART on LV systolic function and cardiovascular morbidity in the future.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...