Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
1.
World J Gastrointest Surg ; 16(6): 1933-1938, 2024 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-38983322

RESUMO

BACKGROUND: The combination of magnetic compression anastomosis (MCA) and endoscopy has been used to treat biliary stricture after liver transplantation. However, its use for the treatment of complex biliary obstruction after major abdominal trauma has not been reported. This case report describes the successful use of MCA for the treatment of biliary obstruction resulting from major abdominal trauma. CASE SUMMARY: A 23-year-old man underwent major abdominal surgery (repair of liver rupture, right half colon resection, and ileostomy) following a car accident one year ago. The abdominal drainage tube, positioned at the Winslow foramen, was draining approximately 600-800 mL of bile per day. During the two endoscopic retrograde cholangiopancreatography procedures, the guide wire was unable to enter the common bile duct, which prevented placement of a biliary stent. MCA combined with endoscopy was used to successfully achieve magnetic anastomosis of the peritoneal sinus tract and duodenum, and then a choledochoduodenal stent was placed. Finally, the external biliary drainage tube was removed. The patient achieved internal biliary drainage leading to the removal of the external biliary drainage tube, which improved the quality of life. CONCLUSION: Magnetic compression technique can be used for the treatment of complex biliary obstruction with minimal operative trauma.

2.
Sci Rep ; 14(1): 14265, 2024 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-38902360

RESUMO

With the increasing application of magnetic compression anastomosis (MCA) in gastrointestinal anastomosis, we identified an interesting phenomenon that an anastomosis is more prone to stenosis after endoscopic gastrointestinal MCA. We hypothesized that the increase in tissue tension during endoscopic procedures is the cause of anastomotic stenosis. In this study, we investigated the effect of tissue tension on gastroduodenal bypass MCA in Sprague-Dawley (SD) rats. Twenty SD rats were divided into the study group (high-tension group, n = 10) and control group (no tension group, n = 10), wherein the rats underwent complete gastroduodenal bypass magnetic anastomosis under high tension and no tension of the digestive tract, respectively. Anastomotic specimens were obtained 4 weeks after the operation, and anastomotic diameters of the two groups were observed and measured. The histological difference was observed by hematoxylin & eosin and Masson staining. The operation was successfully completed in all rats, and all survived until 4 weeks postoperatively. Anastomotic measurements revealed that the anastomosis diameter was significantly smaller in the study group than in the control group, and there were three cases of severe anastomotic stenosis. Histological observation showed that the amount of collagen fibers in the anastomosis was greater in the study group than in the control group. The results suggest that the high-tension state of the digestive tract is an important factor leading to anastomotic stenosis, and thus, we put forward the Yan-Zhang's Tissue Tension Theory of MCA to explain this phenomenon.


Assuntos
Anastomose Cirúrgica , Ratos Sprague-Dawley , Animais , Anastomose Cirúrgica/métodos , Ratos , Masculino , Trato Gastrointestinal/cirurgia , Constrição Patológica/cirurgia , Magnetismo
3.
Surg Obes Relat Dis ; 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38879418

RESUMO

BACKGROUND: Means of addressing technical challenges in forming gastrojejunostomy (GJ) anastomoses and maintaining their patency are sought. OBJECTIVES: Evaluation of preclinical feasibility and healing efficacy of a novel linear magnetic compression anastomosis (MCA) device to form a patent GJ versus sutured jejunal enterotomy (JE) sites in swine. SETTING: Single-center veterinary testing facility. METHODS: Feasibility of 3 prototype sizes (4, 6, and 8 cm) of a metal MCA device (MCAD) to form a patent GJ was evaluated over 6 weeks. A distal magnet was laparoscopically inserted in the jejunum, a proximal magnet was placed gastroscopically in the stomach; magnets were aligned to gradually form an anastomosis, self-detached, and be expelled. At necropsy, MCAs were assessed for patency and compared with JE tissues to evaluate wound healing. RESULTS: MCADs aligned at the GJ location without complications. In 5/6 MCAD pairs, dislodgement occurred between 7 and 26 days; expulsion 13-31 days; 1 MCAD pair was retained in the stomach. At necropsy, all pigs were healthy, gaining a mean 15.0 kg. Anastomoses were not adequately patent in 2/4 pigs receiving the 4-cm or 6-cm MCADs because their linear length was too small. But, anastomoses of both pigs receiving the 8-cm MCADs maintained full patency. Minimal inflammation and fibrosis were seen in MCA specimens versus sutured enterotomies. CONCLUSIONS: A novel linear MCA device was feasible and effectively created a patent GJ anastomosis in swine with minimal inflammation and fibrosis. The MCAD may be appropriate for clinical evaluation.

4.
Sci Rep ; 14(1): 10602, 2024 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-38719935

RESUMO

Although the application of magnetic compression anastomosis is becoming increasingly widespread, the magnets used in earlier studies were mostly in the shape of a whole ring. Hence, a deformable self-assembled magnetic anastomosis ring (DSAMAR) was designed in this study for gastrointestinal anastomosis. Furthermore, its feasibility was studied using a beagle model. The designed DSAMAR comprised 10 trapezoidal magnetic units. Twelve beagles were used as animal models, and DSAMARs were inserted into the stomach and colon through the mouth and anus, respectively, via endoscopy to achieve gastrocolic magnamosis. Surgical time, number of failed deformations, survival rate of the animals, and the time of magnet discharge were documented. A month later, specimens of the anastomosis were obtained and observed with the naked eye as well as microscopically. In the gastrocolic anastomosis of the 12 beagles, the procedure took 65-120 min. Although a deformation failure occurred during the operation in one of the beagles, it was successful after repositioning. The anastomosis was formed after the magnet fell off 12-18 days after the operation. Naked eye and microscopic observations revealed that the anastomotic specimens obtained 1 month later were well-formed, smooth, and flat. DSAMAR is thus feasible for gastrointestinal anastomosis under full endoscopy via the natural orifice.


Assuntos
Anastomose Cirúrgica , Estudos de Viabilidade , Animais , Cães , Anastomose Cirúrgica/métodos , Estômago/cirurgia , Imãs , Magnetismo , Cirurgia Endoscópica por Orifício Natural/métodos , Cirurgia Endoscópica por Orifício Natural/instrumentação , Colo/cirurgia , Masculino
5.
J Gastrointest Surg ; 28(5): 640-650, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38704201

RESUMO

BACKGROUND: Single-anastomosis metabolic/bariatric surgery procedures may lessen the incidence of anastomotic complications. This study aimed to evaluate the feasibility and safety of performing side-to-side duodenoileal (DI) bipartition using magnetic compression anastomosis (MCA). In addition, preliminary efficacy, quality of life (QoL), and distribution of food through the DI bipartition were evaluated. METHODS: Patients with a body mass index (BMI) of ≥35.0 to 50.0 kg/m2 underwent side-to-side DI bipartition with the magnet anastomosis system (MS) with sleeve gastrectomy (SG). By endoscopic positioning, a distal magnet (250 cm proximal to the ileocecal valve) and a proximal magnet (first part of the duodenum) were aligned with laparoscopic assistance to inaugurate MCA. An isotopic study assessed transit through the bipartition. RESULTS: Between March 14, 2022 to June 1, 2022, 10 patients (BMI of 44.2 ± 1.3 kg/m2) underwent side-to-side MS DI. In 9 of 10 patients, an SG was performed concurrently. The median operative time was 161.0 minutes (IQR, 108.0-236.0), and the median hospital stay was 3 days (IQR, 2-40). Paired magnets were expelled at a median of 43 days (IQR, 21-87). There was no device-related serious advanced event within 1 year. All anastomoses were patent with satisfactory diameters after magnet expulsion and at 1 year. Respective BMI, BMI reduction, and total weight loss were 28.9 ± 1.8 kg/m2, 15.2 ± 1.8 kg/m2, and 34.2% ± 4.1%, respectively. Of note, 70.0% of patients reported that they were very satisfied. The isotopic study found a median of 19.0% of the meal transited through the ileal loop. CONCLUSION: Side-to-side MCA DI bipartition with SG in adults with class II to III obesity was feasible, safe, and efficient with good QoL at 1-year follow-up. Moreover, 19% of ingested food passed directly into the ileum.


Assuntos
Anastomose Cirúrgica , Duodeno , Estudos de Viabilidade , Gastrectomia , Imãs , Humanos , Gastrectomia/métodos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Duodeno/cirurgia , Anastomose Cirúrgica/métodos , Seguimentos , Obesidade Mórbida/cirurgia , Íleo/cirurgia , Qualidade de Vida , Laparoscopia/métodos , Índice de Massa Corporal , Duração da Cirurgia , Cirurgia Bariátrica/métodos , Resultado do Tratamento , Trânsito Gastrointestinal
6.
Gastrointest Endosc ; 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38762041

RESUMO

BACKGROUND & AIMS: Post-cholecystectomy biliary strictures can be treated surgically or non-surgically. Although endoscopic or percutaneous treatments are the preferred approaches, these methods are not feasible in cases where complete stricture occlusion prevents the successful passage of a guidewire. The utility of magnetic compression anastomosis (MCA) in patients with post-cholecystectomy complete biliary obstruction that cannot be treated conventionally was evaluated. METHODS: MCA was performed in 10 patients with post-cholecystectomy biliary strictures that did not resolve with conventional endoscopic or percutaneous treatment. One magnet was delivered through the percutaneous transhepatic biliary drainage tract, and another was advanced via endoscopic retrograde cholangiopancreatography(ERCP) of the common bile duct. After magnet approximation and recanalization, a fully covered self-expandable metal stent (FCSEMS) was placed for 3 months and then replaced for a further 3 months. Stricture resolution was evaluated after FCSEMS removal. RESULTS: Among the 10 patients who underwent MCA for post-cholecystectomy biliary stricture, the biliary injury was Strasberg type B in 2, type C in 3, and type E in 5. Recanalization was successful in all patients (technical success rate 100%). The mean follow-up period after recanalization was 50.2 months (range 13.2-116.8 months). Partial restenosis after MCA occurred in two patients at 24.1 and 1.6 months after stent removal. ERCP with FCSEMS placement resolved the recurrent stenosis in both patients. CONCLUSIONS: MCA is a useful alternative nonsurgical treatment for complete biliary obstruction after cholecystectomy that cannot be resolved by conventional methods.

7.
Insights Imaging ; 15(1): 128, 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38816640

RESUMO

Obstructions encountered in biliary, gastrointestinal, and urinary tracts are increasing in number due to successful percutaneous and endoscopic organ-saving procedures. Although functional recovery is established to an extent, failure of traversing an obstruction may end up necessitating invasive surgical procedures. Multidisciplinary collaboration may traverse the limitations of each individual approach, therefore creating the perfect intervention for the patient. Magnetic compression anastomosis is a minimally invasive procedure that can provide a great outcome in select cases with biliary, gastrointestinal, or urinary tract obstructions. CRITICAL RELEVANCE STATEMENT: In this article, various applications of magnetic compression anastomosis are reviewed with illustrative cases of esophageal, biliary, colonic, and urinary obstructions that cannot be traversed with a wire. This method will expand the spectrum of interventions performed in the IR unit. KEY POINTS: Magnets can enable wire access beyond an impassable obstruction. Magnets can create anatomical and non-anatomical anastomosis at an occlusion. Magnetic compression anastomosis is a minimally invasive procedure that can provide great outcomes.

8.
J Gastroenterol Hepatol ; 39(7): 1256-1266, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38638082

RESUMO

Magnetic compression anastomosis (MCA) is a new method that provides sutureless passage construction for tubular organs. Due to the high recurrence rate of conventional endoscopic treatment and the high morbidity and mortality of surgical procedures, the MCA technique shows promise. The aim of this review is to comprehensively examine the literature related to the use of MCA in different gastrointestinal diseases over the past few years, categorizing them according to the anastomotic site and describing in detail the various methods of magnet delivery and the clinical outcomes of MCA. MCA is an innovative technique, and its use represents an advancement in the field of minimally invasive interventions. Comparison studies have shown that the anastomosis formed by MCA is comparable to or better than surgical sutures in terms of general appearance and histology. Although most of the current research has involved animal studies or studies with small populations, the safety and feasibility of MCA have been preliminarily demonstrated. Large prospective studies involving populations are still needed to guarantee the security of MCA. For technologies that have been initially used in clinical settings, effective measures should also be implemented to identify, even prevent, complications. Furthermore, specific commercial magnets must be created and optimized in this emerging area.


Assuntos
Anastomose Cirúrgica , Imãs , Humanos , Anastomose Cirúrgica/métodos , Endoscopia Gastrointestinal/métodos , Gastroenteropatias/cirurgia , Animais , Magnetismo , Resultado do Tratamento , Procedimentos Cirúrgicos sem Sutura/métodos , Pressão
9.
World J Gastrointest Surg ; 16(3): 860-870, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38577092

RESUMO

BACKGROUND: Despite much work having been conducted on magnetic compression anastomosis (MCA) in the digestive tract, there are no reports on the influence of magnetic force on the anastomosis. AIM: To investigate the effect of different magnetic force magnets on the MCA of the digestive tract. METHODS: Two groups of magnets of the same sizes but different magnetic forces were designed and produced. A total of 24 Sprague-Dawley rats were randomly assigned into two groups (powerful magnet group and common magnet group), with 12 rats in each group. Two types of magnets were used to complete the colonic side-to-side anastomosis of the rats. The operation time and magnet discharge time were recorded. The anastomotic specimens were obtained 4 wk after the operation and then the burst pressure and diameter of the anastomosis were measured, and the anastomosis was observed via the naked eye and subjected to histological examination. RESULTS: The magnetic forces of the powerful and common magnet groups at zero distance were 8.26 N and 4.10 N, respectively. The colonic side-to-side anastomosis was completed in all 24 rats, and the operation success rate and postoperative survival rate were 100%. No significant difference was noted in the operation time between the two groups. The magnet discharge time of the powerful magnet group was slightly longer than that of the common magnet group, but the difference was not statistically significant (P = 0.513). Furthermore, there was no statistical difference in the burst pressure (P = 0.266) or diameter of magnetic anastomosis (P = 0.095) between the two groups. The gross specimens of the two groups showed good anastomotic healing, and histological observation indicated good mucosal continuity without differences on healing. CONCLUSION: In the rat colonic side-to-side MCA model, both the powerful magnet with 8.26 N and the common magnet with 4.10 N showed no significant impact on the anastomosis establishment process or its effect.

10.
J Pediatr Surg ; 59(3): 437-444, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37838619

RESUMO

INTRODUCTION: Delayed primary repair of esophageal atresia in patients with high-risk physiologic and anatomic comorbidities remains a daunting challenge with an increased risk for peri-operative morbidity and mortality via conventional repair. The Connect-EA device facilitates the endoscopic creation of a secure esophageal anastomosis. This follow-up study reports our long-term outcomes with the novel esophageal magnetic compression anastomosis (EMCA) Connect-EA device for EA repair, as well as lessons learned from the ten first-in-human cases. We propose an algorithm to maximize the advantages of the device for EA repair. METHODS: Under compassionate use approval, from June 2019 to December 2022, ten patients with prohibitive surgical or medical risk factors underwent attempted EMCA with this device. All patients underwent prior gastrostomy, tracheoesophageal fistula ligation (if necessary), and demonstrated pouch apposition prior to EMCA. RESULTS: Successful device deployment and EMCA formation were achieved in nine patients (90%). Mean time to anastomosis formation was 8 days (range 5-14) and the device was retrieved endoscopically in five (56%) cases. At median follow-up of 22 months (range 4-45), seven patients (78%) are tolerating oral nutrition. Balloon dilations (median 4, range 1-11) were performed either prophylactically for radiographic asymptomatic anastomotic narrowing (n = 7, 78%) or to treat clinically-significant anastomotic narrowing (n = 2, 22%) with no ongoing dilations at 3-month follow up post-repair. CONCLUSION: EMCA with the Connect-EA device is a safe and feasible minimally-invasive alterative for EA repair in high-risk surgical patients. Promising post-operative outcomes warrant further Phase I investigation. LEVEL OF EVIDENCE: IV, Case series of novel operative technique without comparison group.


Assuntos
Acetatos , Atresia Esofágica , Fístula Traqueoesofágica , Humanos , Atresia Esofágica/cirurgia , Ensaios de Uso Compassivo , Seguimentos , Anastomose Cirúrgica/métodos , Resultado do Tratamento , Estudos Retrospectivos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
11.
Organ Transplantation ; (6): 297-302, 2024.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1012503

RESUMO

In recent years, with the development of organ preservation, surgical techniques, perioperative management and immunosuppression regimens, the success rate of liver transplantation and survival rate of the recipients have been significantly enhanced. Liver transplantation has become the optimal treatment for patients with end-stage liver disease. However, biliary complications still commonly occur after liver transplantation, especially biliary anastomotic stricture. Severe biliary anastomotic stricture will not only increase the cost of treatment, but also lead to graft loss and even affect the survival rate of recipients. Therefore, timely diagnosis and treatment of biliary anastomotic stricture play a significant role in improving the survival rate of liver transplant recipients. In this article, the risk factors, clinical symptoms, diagnosis and treatment of biliary anastomotic stricture after liver transplantation were reviewed, aiming to provide novel ideas for the research, diagnosis and treatment of biliary anastomotic stricture after liver transplantation, and further enhance clinical efficacy of liver transplantation and the quality of life of recipients.

12.
Surg Obes Relat Dis ; 20(4): 341-352, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38114385

RESUMO

BACKGROUND: Conventional metabolic/bariatric surgical anastomoses with sutures/staples may cause severe adverse events (AEs). OBJECTIVES: The study aim was to evaluate the feasibility, safety, and effectiveness of primary and revisional side-to-side duodeno-ileostomy (DI) bipartition using a novel magnetic compression anastomosis device (Magnet Anastomosis System [MS]). SETTING: Multicenter: private practices and university hospitals. METHODS: In patients with body mass index ([BMI, kg/m2] ≥35.0 to ≤50.0 with/without type 2 diabetes [T2D] glycosylated hemoglobin [HbA1C > 6.5 %]), two linear MS magnets were delivered endoscopically to the duodenum and ileum with laparoscopic assistance and aligned, initiating magnet fusion and gradual DI (MagDI). The MagDI-after-SG group had undergone prior sleeve gastrectomy (SG); the MagDI + SG group underwent concurrent SG. AEs were graded by Clavien-Dindo Classification (CDC). RESULTS: Between November 22, 2021 and May 30, 2023, 43 patients (88.0% female, mean age 43.7 ± 1.3 years) underwent the study procedures. The MS met feasibility criteria of magnet device placement, creation of patent anastomoses confirmed radiologically, and magnet passage in 100.0% of patients. There were 64 AEs, most were CDC grade I and II, significantly fewer in the MagDI-after-SG group (P < .001). No device-related AEs including anastomotic leakage, bleeding, obstruction, infection, or death. The MagDI-after-SG group experienced 6-month mean weight loss of 8.0 ± 2.5 kg (P < .01), 17.4 ± 5.0% excess weight loss (EWL). The MagDI + SG group had significantly greater weight loss (34.2 ± 1.6 kg, P < .001), 66.2 ± 3.4% EWL. All patients with T2D improved. CONCLUSIONS: In early results of a multicenter study, the incisionless, sutureless Magnet System formed patent, complication-free anastomoses in side-to-side DI with prior or concurrent SG.


Assuntos
Diabetes Mellitus Tipo 2 , Derivação Gástrica , Obesidade Mórbida , Adulto , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Obesidade Mórbida/cirurgia , Obesidade Mórbida/etiologia , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/cirurgia , Resultado do Tratamento , Obesidade/cirurgia , Duodeno/cirurgia , Gastrectomia/métodos , Redução de Peso , Estudos Retrospectivos , Fenômenos Magnéticos , Derivação Gástrica/efeitos adversos
13.
J Pediatr Surg ; 2023 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-37968150

RESUMO

BACKGROUND: To assess the feasibility of a deformable self-assembled magnetic anastomosis ring (DSAMAR) in the treatment of esophageal stenosis in beagle dogs via transoral access without temporary gastrostomy. METHODS: Experimental esophageal stenosis was created in 10 beagle dogs by partial cervical esophageal ligation. The DSAMAR was inserted into the distal esophagus via the narrow section of the esophagus using a gastroscope. A circular DSAMAR was placed in the proximal esophagus. The magnetic rings on both sides of the experimental stenosis automatically attracted each other. We then recorded the operation time, postoperative complications, anastomotic formation time, and magnetic ring discharge time. The dogs were euthanized 4 weeks postoperatively; subsequently, we obtained the esophageal anastomotic specimens and observed the anastomotic formation via the naked eye and by light microscopy. RESULTS: Our esophageal stenosis model produced reproducible stenoses in all dogs, which was confirmed via endoscopy and esophagography. DSAMAR was successfully implanted in all experimental animals under endoscopic and X-ray monitoring, and all linear DSAMARs were successfully transformed into rings. The magnets at both ends of the esophageal stenosis were automatically attracted. All animals survived until euthanasia. No complications, including esophageal perforation, bleeding, and gastrointestinal obstruction, were noted during the perioperative period. The mean operation time of endoscopic magnetic anastomosis was 15.6 ± 2.41 (range, 12-19) min. The mean esophageal anastomotic formation time was 8.8 ± 1.03 (range, 7-10) days, and the mean expulsion time of DSAMAR was 13.94 ± 2.88 (range, 10-19) days. Gastroscopy and esophagography were performed at 4 weeks postoperatively; the esophageal patency was good. Macroscopic observation of the esophageal anastomotic specimens revealed that the esophageal mucosal layer of the anastomosis had good continuity and the anastomosis was smooth. CONCLUSION: DSAMAR is a feasible option for magnetic recanalization of esophageal stricture via transoral access without temporary gastrostomy.

14.
J Laparoendosc Adv Surg Tech A ; 33(12): 1223-1230, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37603306

RESUMO

Background: Magnetic compression anastomosis (MCA) is an alternative technique for patients with long-gap esophageal atresia (EA). It allows for preservation of the native esophagus. We aimed to systematically summarize the current literature on MCA in EA. Methods: Studies where neonates with EA were treated with MCA devices were included, while studies on esophageal stenosis were excluded. All clinical studies, including comparative studies, case series, and case reports, were eligible for inclusion. Methodological quality assessment was performed using a validated tool. Results: Twelve studies with a total of 42 patients were included in this review. There was a wide variation among these studies with regard to the time of initiation of MCA (1 day to 7 months), procedure time (13-320 minutes), and magnet characteristics (strength, size, and shape of the magnets used). The time to achieve anastomosis ranged from 1 to 12 days. Stricture at the anastomotic site was reported in almost all the patients, which required multiple endoscopic dilatations (median no. of dilatations/patient = 9.8). Stent placement for refractory stricture was required in 9 (21%) patients, and surgery for stricture was required in 6 (14%) patients. Long-term outcomes included esophageal dysmotility (n = 3) and recurrent pulmonary infections (n = 3) were reported in only four studies. Conclusion: As per the findings of this review, neonates with long-gap EA undergoing MCA would invariably require multiple sittings of endoscopic dilatations (median no. of dilatations/patient = 9.8). Also, there is a wide variation among the included studies in terms of the procedure of MCA. Future studies with a standardized procedure for achieving MCA are needed to determine additional outcomes in this fragile patient population.


Assuntos
Atresia Esofágica , Estenose Esofágica , Recém-Nascido , Humanos , Atresia Esofágica/cirurgia , Atresia Esofágica/complicações , Constrição Patológica/etiologia , Estenose Esofágica/etiologia , Estenose Esofágica/cirurgia , Anastomose Cirúrgica/métodos , Fenômenos Magnéticos , Resultado do Tratamento , Estudos Retrospectivos
15.
Children (Basel) ; 10(8)2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37628327

RESUMO

Originating in the 1970s, magnetic compression anastomosis (MCA) has lately been revisited with a focus on minimal invasive surgery (MIS). The aim of this report is to reappraise our earlier experience with MCA with the intention of facilitating future MCA advancement. A retrospective review was conducted regarding preclinical experiments and clinical trials at a single institution from 1980 to 1995. The reviewed information was compiled and appraised to generate proposals for future MCA use. The experimental studies, including 250 MCA cases in gastrointestinal and urinary tract animal models, demonstrated the technical versatility of MCA as well as the superior biomechanical characteristics in comparison to hand-sewn anastomoses. Clinical trials encompassed 87 MCA procedures in 86 children, 2 to 10 years of age, involving the following techniques: non-operative esophageal recanalization (n = 15), non-operative ileostomy undiversion (n = 46), Swenson pull-through (n = 10), non-operative urethral recanalization (n = 5), and extravesical ureterocystoneostomy (n = 11). Clinical MCA was found to be successful in over 87% of cases. MCA limitations concerning anastomotic failure and scarring were thought to be mostly due to inadequate magnetic compression. Based on our historic experience, we propose further research on the technical aspects of MCA, along with the biological aspects of anastomotic tissue remodeling. Magnets should be designed and manufactured for a wide spectrum of pediatric surgical indications, particularly in combination with novel MIS techniques.

16.
World J Gastrointest Surg ; 15(7): 1294-1303, 2023 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-37555127

RESUMO

BACKGROUND: Magnetic compression anastomosis (MCA) is a simple procedure contributing to a reliable anastomosis. However, digestive-tract reconstruction after total gastrectomy using MCA has not yet been reported. AIM: To investigate the feasibility of MCA for simultaneous esophagojejunostomy and jejunojejunostomy after total gastrectomy using beagle dogs. METHODS: Sixteen beagles were randomly divided into an MCA group (study group, n = 8) and a manual-suture anastomosis group (control group, n = 8). Two different magnetic anastomosis devices were used in the study group for esophagojejunal and jejunojejunal anastomoses. Both devices included a pair of circular daughter and parent magnets each. The time of esophagojejunostomy and jejunojejunostomy, postoperative complications, and survival rate of the two groups were compared. The dogs were sacrificed one month after the operation and their anastomotic specimens were obtained. Healing was observed by the naked eye and a light microscope. RESULTS: Digestive-tract reconstruction after total gastrectomy was successfully completed in both groups (survival rate = 100%). In the study group, esophagojejunal and jejunojejunal anastomoses took 6.13 ± 0.58 and 4.06 ± 0.42 min, respectively, significantly lower than those in the control group (15.63 ± 1.53 min, P < 0.001 and 10.31 ± 1.07 min, P < 0.001, respectively). Complications such as bleeding, anastomotic leakage, and anastomotic stenosis were not observed. In the study group, the magnets did not interfere with each other. Discharge time of the jejunojejunal magnetic anastomosis device was 10.75 ± 1.28 d, while that of the esophagojejunal magnetic anastomosis device was 12.25 ± 1.49 d. Residual silk was found in the control group. The study group showed a greater smoothness of the anastomosis than that of the control group. All layers of anastomosis healed well in both groups. CONCLUSION: MCA is a safe and feasible procedure for digestive-tract reconstruction after total gastrectomy in this animal model.

17.
Obes Surg ; 33(8): 2282-2292, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37393568

RESUMO

PURPOSES: Classical gastrointestinal anastomoses are formed with sutures and/or metal staples, resulting in significant bleeding and leak rates. This study evaluated the feasibility and safety of the novel magnet anastomosis system (MS) to create a side-to-side duodeno-ileal (DI) diversion for weight loss and type 2 diabetes (T2D) resolution. MATERIALS AND METHODS: Patients with severe obesity (body mass index (BMI) ≥ 35 kg/m2 with/without T2D (HbA1C ≥ 6.5%)) underwent the study procedure, a side-to-side MS DI diversion, with a standard sleeve gastrectomy (SG). A linear magnet was delivered by flexible endoscopy to a point 250 cm proximal to the ileocecal valve; a second magnet was positioned in the first part of the duodenum; the bowel segments containing magnets were apposed, initiating gradual anastomosis formation. Laparoscopic assistance was used to obtain bowel measurements, obviate tissue interposition, and close mesenteric defects. RESULTS: Between November 22 and 26, 2021, 5 female patients (mean weight 117.6 ± 7.1 kg, BMI (kg/m2) 44.4 ± 2.2) underwent side-to-side MS DI + SG. All magnets were successfully placed, expelled without re-intervention, and formed patent durable anastomoses. Total weight loss at 12 months was 34.0 ± 1.4% (SEM); excess weight loss, 80.2 ± 6.6%; and BMI reduction, 15.1. Mean HbA1C (%) dropped from 6.8 ± 0.8 to 4.8 ± 0.2; and glucose (mg/dL), from 134.3 ± 17.9 to 87.3 ± 6.3 (mean reduction, 47.0 mg/dL). There was no anastomotic bleeding, leakage, obstruction, or infection and no mortality. CONCLUSIONS: Creation of a side-to-side magnetic compression anastomosis to achieve duodeno-ileostomy diversion in adults with severe obesity was feasible and safe, achieved excellent weight loss, and resolved type 2 diabetes at 1-year follow-up. TRIAL REGISTRATION: Clinicaltrials.gov Identifier: NCT05322122.


Assuntos
Diabetes Mellitus Tipo 2 , Derivação Gástrica , Obesidade Mórbida , Adulto , Feminino , Humanos , Anastomose Cirúrgica/métodos , Diabetes Mellitus Tipo 2/cirurgia , Duodeno/cirurgia , Gastrectomia/métodos , Derivação Gástrica/métodos , Hemoglobinas Glicadas , Fenômenos Magnéticos , Imãs , Obesidade/cirurgia , Obesidade Mórbida/cirurgia , Estudos Retrospectivos , Redução de Peso
18.
Surg Endosc ; 37(8): 6452-6463, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37217682

RESUMO

INTRODUCTION: Gastrointestinal anastomoses with classical sutures and/or metal staples have resulted in significant bleeding and leak rates. This multi-site study evaluated the feasibility, safety, and preliminary effectiveness of a novel linear magnetic compression anastomosis device, the Magnet System (MS), to form a side-to-side duodeno-ileostomy (DI) diversion for weight loss and type 2 diabetes (T2D) resolution. METHODS: In patients with class II and III obesity (body mass index [BMI, kg/m2] ≥ 35.0- ≤ 50.0 with/without T2D [HbA1C > 6.5%]), two linear MS magnets were delivered endoscopically to the duodenum and ileum with laparoscopic assistance and aligned, initiating DI; sleeve gastrectomy (SG) was added. There were no bowel incisions or retained sutures/staples. Fused magnets were expelled naturally. Adverse events (AEs) were graded by Clavien-Dindo Classification (CDC). RESULTS: Between November 22, 2021 and July 18, 2022, 24 patients (83.3% female, mean ± SEM weight 121.9 ± 3.3 kg, BMI 44.4 ± 0.8) in three centers underwent magnetic DI. Magnets were expelled at a median 48.5 days. Respective mean BMI, total weight loss, and excess weight loss at 6 months (n = 24): 32.0 ± 0.8, 28.1 ± 1.0%, and 66.2 ± 3.4%; at 12 months (n = 5), 29.3 ± 1.5, 34.0 ± 1.4%, and 80.2 ± 6.6%. Group mean respective mean HbA1C and glucose levels dropped to 1.1 ± 0.4% and 24.8 ± 6.6 mg/dL (6 months); 2.0 ± 1.1% and 53.8 ± 6.3 mg/dL (12 months). There were 0 device-related AEs, 3 procedure-related serious AEs. No anastomotic bleeding, leakage, stricture, or mortality. CONCLUSION: In a multi-center study, side-to-side Magnet System duodeno-ileostomy with SG in adults with class III obesity appeared feasible, safe, and effective for weight loss and T2D resolution in the short term.


Assuntos
Diabetes Mellitus Tipo 2 , Derivação Gástrica , Obesidade Mórbida , Adulto , Humanos , Feminino , Masculino , Imãs , Diabetes Mellitus Tipo 2/cirurgia , Duodeno/cirurgia , Anastomose Cirúrgica/métodos , Obesidade/cirurgia , Gastrectomia/métodos , Redução de Peso , Obesidade Mórbida/cirurgia , Estudos Retrospectivos , Derivação Gástrica/métodos
19.
Surg Endosc ; 37(8): 6197-6207, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37170025

RESUMO

BACKGROUND: Minimally invasive metabolic/bariatric surgery (MBS) may be further advanced by magnetic compression anastomosis (MCA) technology. The study aimed to develop a magnet sized to create a patent duodeno-ileostomy (DI) and verify its effectiveness in a porcine model. METHODS: Developmental study phase: magnets with 4 different flange-offset dimensions were tested to identify a design that would successfully form a compression anastomosis. Verification phase: evaluation of the selected design's efficacy. In each 6-week phase (4 pigs/phase), one magnet was inserted laparoscopically in the jejunum, one placed gastroscopically in the duodenum. Magnets were aligned, gradually fused, formed an anastomosis, and then detached and were expelled. At necropsy, MCA sites and sutured enterotomy sites were collected and compared. RESULTS: Developmental phase: the linear BC42 magnet with a 2.3-mm flange offset design was selected. Verification phase: in 4 swine magnets were mated at the target location, confirmed radiographically. Mean time to magnet detachment 16.0 days (12-22), to expulsion 24.5 days (17-33). MCA was achieved in all animals at time of sacrifice. Animals gained a mean 9.5 kg (3.9-11.8). Specimens revealed patent anastomoses of ≥ 20 mm with smooth mucosa and minimal inflammation and fibrosis compared to sutured enterotomies. One pig underwent corrective surgery for a mesenteric hernia without sequelae. CONCLUSION: In a large-animal model, gross and histopathologic examination confirmed that the linear MCA device created a patent, well-vascularized, duodeno-ileal anastomosis. The novel MCA device may be appropriate for use in human MBS procedures.


Assuntos
Magnetismo , Imãs , Humanos , Suínos , Animais , Estudos de Viabilidade , Anastomose Cirúrgica/métodos , Duodeno/cirurgia , Fenômenos Magnéticos
20.
World J Gastrointest Surg ; 15(12): 2919-2925, 2023 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-38222016

RESUMO

BACKGROUND: Esophageal atresia (EA) is a life-threatening congenital malformation in newborns, and the traditional repair approaches pose technical challenges and are extremely invasive. Therefore, surgeons have been actively investigating new minimally invasive techniques to address this issue. Magnetic compression anastomosis has been reported in several studies for its potential in repairing EA. In this paper, the primary repair of EA with magnetic compression anastomosis under thoracoscopy was reported. CASE SUMMARY: A full-term male weighing 3500 g was diagnosed with EA gross type C. The magnetic devices used in this procedure consisted of two magnetic rings and several catheters. Tracheoesophageal fistula ligation and two purse strings were performed. The magnetic compression anastomosis was then completed thoracoscopically. After the primary repair, no additional operation was conducted. A patent anastomosis was observed on the 15th day postoperatively, and the magnets were removed on the 23rd day. No leakage existed when the transoral feeding started. CONCLUSION: Thoracoscopic magnetic compression anastomosis may be a promising minimally invasive approach for repairing EA.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...