Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 111
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Nano Lett ; 24(34): 10467-10474, 2024 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-39096282

RESUMO

Spin-mechanical coupling is vital in diverse fields including spintronics, sensing, and quantum transduction. Two-dimensional (2D) magnetic materials provide a unique platform for investigating spin-mechanical coupling, attributed to their mechanical flexibility and novel spin orderings. However, studying their spin-mechanical coupling presents challenges in probing mechanical deformation and thermodynamic property changes at the nanoscale. Here we use nano-optoelectromechanical interferometry to mechanically detect the phase transition and magnetostriction effect in multilayer CrSBr, an air-stable antiferromagnet with large magnon-exciton coupling. The transitions among antiferromagnetism, spin-canted ferromagnetism, and paramagnetism are visualized. Nontrivial magnetostriction coefficient 2.3 × 10-5 and magnetoelastic coupling strength on the order of 106 J/m3 have been found. Moreover, we demonstrate the substantial tunability of the magnetoelastic constant by nearly 50% via gate-induced strain. Our findings demonstrate the strong spin-mechanical coupling in CrSBr and pave the way for developing sensitive magnetic sensing and efficient quantum transduction at the atomically thin limit.

2.
Nano Lett ; 24(34): 10562-10568, 2024 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-39159397

RESUMO

MnBi2Te4 is a magnetic topological insulator with layered A-type antiferromagnetic order. It exhibits a rich layer- and magnetic-state dependent topological phase diagram; however, much about the coupling between spin, charge, and lattice remains to be explored. In this work, we report that MnBi2Te4 is an excellent acoustic phonon cavity by realizing phonon frequency combs using picosecond ultrasonics. With the generated acoustic phonon wavepackets, we demonstrate that the timing and phase of acoustic echoes can be used to detect the presence of stacking faults between van der Waals layers buried deep within the crystal. Furthermore, by implementing this nondestructive ultrafast optical measurement in conjunction with time-resolved magneto-optical Kerr effect experiments, we uncover that out-of-plane vibrations in MnBi2Te4 do not couple to the magnetic order, i.e. there is no appreciable magnetostriction. Our work points out how a well-developed technique can probe the structural defects and phonon pulse engineering in layered topological insulators.

3.
Sensors (Basel) ; 24(14)2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39066054

RESUMO

Inkjet printing of magnetic materials has increased in recent years, as it has the potential to improve research in smart, functional materials. Magnetostriction is an inherent property of magnetic materials which allows strain or magnetic fields to be detected. This makes it very attractive for sensors in the area of structural health monitoring by detecting internal strains in carbon fibre-reinforced polymer (CFRP) composite. Inkjet printing offers design flexibility for these sensors to influence the magnetic response to the strain. This allows the sensor to be tailored to suit the location of defects in the CFRP. This research has looked into the viability of printable soft magnetic materials for structural health monitoring (SHM) of CFRP. Magnetite and nickel ink dispersions were selected to print using the JetLab 4 drop-on-demand technique. The printability of both inks was tested by selecting substrate, viscosity and solvent evaporation. Clogging was found to be an issue for both ink dispersions. Sonicating and adjusting the jetting parameters helped in distributing the nanoparticles. We found that magnetite nanoparticles were ideal as a sensor as there is more than double increase in saturation magnetisation by 49 Am2/kg and more than quadruple reduction of coercive field of 5.34 kA/m than nickel. The coil design was found to be the most sensitive to the field as a function of strain, where the gradient was around 80% higher than other sensor designs. Additive layering of 10, 20 and 30 layers of a magnetite square patch was investigated, and it was found that the 20-layered magnetite print had an improved field response to strain while maintaining excellent print resolution. SHM of CFRP was performed by inducing a strain via bending and it was found that the magnetite coil detected a change in field as the strain was applied.

4.
J Adv Res ; 2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38844125

RESUMO

INTRODUCTION: Magnetostrictive Fe-Ga alloys have garnered extensive attention owing to their excellent magnetic properties and acceptable biocompatibility. Nevertheless, the polycrystalline Fe-Ga alloys currently available tend to display random texture orientations, which constrain their magnetostrictive performance. OBJECTIVES: To regulate the texture orientation of Fe-Ga-NbC alloys and thereby enhancing magnetostriction. METHODS: In this study, a processing route comprising laser powder bed fusion (LPBF) followed by secondary recrystallization annealing (800, 1000, and 1200 °C, respectively) was developed to prepare Fe-Ga-NbC alloys. RESULTS: The results showed that the LPBF-ed (Fe81Ga19)99(NbC)1 alloys exhibited a high content of high energy grain boundaries (HEGBs) due to the repeated melting and solidification. In subsequent annealing process, the migration of HEGBs induced the rearrangement and recrystallization of grains, during which NbC was found to locate at the grain boundaries and influence the migration path of HEGBs via selective pinning, thereby resulting in a strong Goss texture. With the rise in annealing temperature, the content of Goss texture gradually increased from the initial 3.9 % to 71.3 % at 1200 °C, leading to enhanced magnetostriction, lower saturation magnetization and coercivity. Furthermore, in alternating magnetic fields, the alloys annealed at 1200 °C also exhibited higher magnetostriction than the LPBF-ed alloys. And a noteworthy grain coarsening was also observed after annealing, accompanied by a discernible inclination of magnetic domains towards strip domains. Additional, cell tests demonstrated that the prepared alloys had satisfactory biocompatibility and the ability to promote osteogenic differentiation. CONCLUSION: These findings indicated that the LPBF-ed and annealed Fe-Ga-NbC alloys might be a promising alternative as magnetostrictive-driven materials for biomedical applications.

5.
Adv Mater ; 36(35): e2404192, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38925664

RESUMO

Rapid development of smart technologies poses a big challenge for magnetostrictive materials, which should not only permit isotropic and hysteresis-free actuation (i.e., nonhysteretic volume change) in magnetic fields, but also have high strength and high ductility. Unfortunately, the magnetostriction from self-assembly of ferromagnetic domains is volume-conserving; the volume magnetostriction from field-induced first-order phase transition has large intrinsic hysteresis; and most prototype magnetostrictive materials are intrinsically brittle. Here, a magnetic high-entropy alloy (HEA) Fe35Co35Al10Cr10Ni10 is reported that can rectify these challenges, exhibiting an unprecedented combination of large nonhysteretic volume magnetostriction, high tensile strength and large elongation strain, over a wide working temperature range from room temperature down to 100 K. Its exceptional properties stem from a dual-phase microstructure, where the face-centered cubic (FCC) matrix phase with nanoscale compositional and structural fluctuations can enable a magnetic-field-induced transition from low-spin small-volume state to high-spin large-volume state, and the ordered body-centered cubic (BCC) B2 phase contributes to mechanical strengthening. The present findings may provide insights into designing unconventional and technologically important magnetostrictive materials.

6.
Nanotechnology ; 35(32)2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38688252

RESUMO

Stochastic neurons are efficient hardware accelerators for solving a large variety of combinatorial optimization problems. 'Binary' stochastic neurons (BSN) are those whose states fluctuate randomly between two levels +1 and -1, with the probability of being in either level determined by an external bias. 'Analog' stochastic neurons (ASNs), in contrast, can assume any state between the two levels randomly (hence 'analog') and can perform analog signal processing. They may be leveraged for such tasks as temporal sequence learning, processing and prediction. Both BSNs and ASNs can be used to build efficient and scalable neural networks. Both can be implemented with low (potential energy) barrier nanomagnets (LBMs) whose random magnetization orientations encode the binary or analog state variables. The difference between them is that the potential energy barrier in a BSN LBM, albeit low, is much higher than that in an ASN LBM. As a result, a BSN LBM has a cleardouble well potential profile, which makes its magnetization orientation assume one of two orientations at any time, resulting in the binary behavior. ASN nanomagnets, on the other hand, hardly have any energy barrier at all and hence lack the double well feature. That makes their magnetizations fluctuate in an analog fashion. Hence, one can reconfigure an ASN to a BSN, and vice-versa, by simply raising and lowering the energy barrier. If the LBM ismagnetostrictive, then this can be done with local (electrically generated) strain. Such a reconfiguration capability heralds a powerful field programmable architecture for a p-computer whereby hardware forvery different functionalitiessuch as combinatorial optimization and temporal sequence learning can be integrated in the same substrate in the same processing run. This is somewhat reminiscent of heterogeneous integration, except this is integration of functionalities or computational fabrics rather than components. The energy cost of reconfiguration is miniscule. There are also other applications of strain mediated barrier control that do not involve reconfiguring a BSN to an ASN or vice versa, e.g. adaptive annealing in energy minimization computing (Boltzmann or Ising machines), emulating memory hierarchy in a dynamically reconfigurable fashion, and control over belief uncertainty in analog stochastic neurons. Here, we present a study of strain engineered barrier control in unconventional computing.

7.
Materials (Basel) ; 17(6)2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38541559

RESUMO

We investigated the ultrafast dynamics of a SrRuO3/BiFeO3 superlattice grown on a SrTiO3 substrate using a near infrared pump-probe technique at various temperatures. The superlattice exhibits a ferromagnetic order inherited from the SrRuO3 layer. The pump-induced changes in the reflectivity reveal periodic oscillations. We found that the oscillation frequency can be well explained by zone-folded acoustic phonon oscillations, whose dispersion depends on the sound velocity, density, and thickness within the supercell of each constituent layer. It is found that the observed oscillation frequency corresponds to the A1 mode, which suggests that oscillations are excited due to pump-induced expansion of the SrRuO3 layer that absorbs the pump photon. Temperature-dependent measurements reveal significant suppression of the oscillation amplitude in the ferromagnetic state. The suppressed amplitude is proportional to the square of the magnetization, M(T)2. This phenomenon can be attributed to a strong magnetostriction effect of SrRuO3 that suppresses lattice expansion upon pumping.

8.
Polymers (Basel) ; 16(5)2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38475268

RESUMO

Significant deformations of bodies made from compliant magnetoactive elastomers (MAE) in magnetic fields make these materials promising for applications in magnetically controlled actuators for soft robotics. Reported experimental research in this context was devoted to the behaviour in the quasi-static magnetic field, but the transient dynamics are of great practical importance. This paper presents an experimental study of the transient response of apparent longitudinal and transverse strains of a family of isotropic and anisotropic MAE cylinders with six different aspect ratios in time-varying uniform magnetic fields. The time dependence of the magnetic field has a trapezoidal form, where the rate of both legs is varied between 52 and 757 kA/(s·m) and the maximum magnetic field takes three values between 153 and 505 kA/m. It is proposed to introduce four characteristic times: two for the delay of the transient response during increasing and decreasing magnetic field, as well as two for rise and fall times. To facilitate the comparison between different magnetic field rates, these characteristic times are further normalized on the rise time of the magnetic field ramp. The dependence of the normalized characteristic times on the aspect ratio, the magnetic field slew rate, maximum magnetic field values, initial internal structure (isotropic versus anisotropic specimens) and weight fraction of the soft-magnetic filler are obtained and discussed in detail. The normalized magnetostrictive hysteresis loop is introduced, and used to explain why the normalized delay times vary with changing experimental parameters.

9.
Sci Rep ; 14(1): 6601, 2024 03 19.
Artigo em Inglês | MEDLINE | ID: mdl-38503814

RESUMO

Tooth wear and pain are the primary concerns of patients undergoing periodontal scaling. The aims of this study were to compare the effects of a new magnetostrictive ultrasonic scaler and a traditional piezoelectric ultrasonic scaler on tooth surface roughness and calculus removal and to determine their impacts on patient discomfort during supragingival cleaning. This article had two parts: an in vitro study and a clinical study. In the in vitro study, thirty teeth with subgingival calculus were randomly assigned to two scaling treatment groups: magnetostrictive scalers (n = 15) and piezoelectric scalers (n = 15). Surface roughness measurements were taken at baseline and after scaling, and the root samples were visualised by SEM after scaling. Additionally, a single-centre randomised split-mouth clinical trial was conducted. Eighty-five participants diagnosed with chronic gingivitis or periodontitis were randomly assigned to receive supragingival scaling. The magnetostrictive scaler was used in half of the mouths (n = 85), and the piezoelectric scaler was used in the other half of the mouths (n = 85). Data on pain, noise, and vibration were collected using a VAS questionnaire, and the operating time was recorded. In both in vitro and clinical studies, magnetostrictive scalers were reported to be more effective than piezoelectric scalers in removing dental deposits (P < 0.05). Additionally, the root surface after scaling with the magnetostrictive scaler was smoother than that after scaling with the piezoelectric scaler in the in vitro study (P = 0.02). SEM examination also revealed that fewer dental materials were lost after instrumentation with the magnetostrictive scaler than after instrumentation with the piezoelectric scaler. Piezoelectric scalers caused less discomfort to patients in terms of pain, noise, and vibration than magnetostrictive scalers (P < 0.05). According to this clinical study, the magnetostrictive scaler caused more discomfort during supragingival scaling than the piezoelectric scaler. Moreover, the magnetostrictive scaler was also more efficient and produced a smoother root surface with less material loss after scaling than the piezoelectric scaler, as demonstrated in the in vitro study.


Assuntos
Cálculos , Dente , Terapia por Ultrassom , Humanos , Ultrassom , Raiz Dentária , Dor
10.
Ultrasonics ; 138: 107218, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38109805

RESUMO

The present paper deals with the problem of elastic wave generation mechanisms (WGMs) by an electromagnetic-acoustic transducer (EMAT) in ferromagnetic materials. The paper seeks to prove that taking into account all the WGMs must be a general rule to quantitatively predict the elastic waves generated by an EMAT in such materials. Existing models of the various physical phenomena involved, namely magnetic and magnetostrictive, electromagnetic, and ultrasonic, are combined to solve the multiphysics wave generation problem. The resulting model shows that WGMs (i.e., electromagnetic force, magnetostrictive strain, and magnetic traction) strongly depend on material properties and EMAT design and excitation. To illustrate this, four magnetic materials (nickel, AISI410, Z20C13, and low carbon steel) with similar elastic but contrasting electromagnetic properties are studied. A given EMAT of fixed excitation and geometry yields WGMs with highly different amplitudes in these materials, with a WGM dominant in one material being negligible in another. Experimental results make it possible to validate the accuracy of certain predictions of the model developed. In summary, the present work shows that considering all WGMs is the general rule when working with ferromagnetic materials. Furthermore, it offers a generic model that can be integrated into various numerical tools to help optimize EMAT design and give reliable data interpretation.

11.
Nanomaterials (Basel) ; 13(23)2023 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-38063704

RESUMO

Defects are an inevitable occurrence during the manufacturing and use of ferromagnetic materials, making it crucial to study the microscopic mechanism of magnetostrictive properties of ferromagnetic materials with defects. This paper conducts molecular dynamics simulations on low-dimensional iron thin films containing hole or crack defects, analyzes and compares the impact of defect size on magnetostrictive properties, and investigates the microscopic mechanism of their effects. The results indicate that the saturation magnetostrictive strains of the defect models do not increase monotonically as the defect size increases. Additionally, it is discovered that the arrangement of atomic magnetic moments in the initial magnetic moment configuration also affects the magnetostrictive properties. When controlling the size of the hole or crack within a certain defect area, it is found that the hole size has less influence on the initial magnetic moment configuration, resulting in a smaller corresponding change in the saturation strain and thus having a lesser impact on the magnetostrictive properties. Conversely, when the crack size changes, the arrangement of the atomic magnetic moments in the initial magnetic moment configuration changes more significantly, resulting in a greater corresponding change in saturation strain, and thus having a greater impact on the magnetostriction performance.

12.
Sensors (Basel) ; 23(24)2023 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-38139468

RESUMO

The resonant magnetoelectric (ME) effect of Fe78Si9B13/Pb(Zr,Ti)O3 (FeSiB/PZT) composites with a surface-modified Fe78Si9B13 amorphous alloy has been studied. The surface-modified FeSiB can improve the ME coefficient at the resonant frequency by optimizing the magnetomechancial power conversion efficiency. The maximum ME coefficient of the surface-modified ribbons combined with soft PZT (PZT5) is two-thirds larger than that of the composites with fully amorphous ribbons. Meanwhile, the maximum value of the ME coefficient with surface-modified FeSiB ribbons and hard PZT (PZT8) is one-third higher compared with the fully amorphous composites. In addition, experimental results of magnetomechanical coupling properties of FeSiB/PZT composites with or without piezoelectric layers indicate that the power efficiency of the composites first decreases and then increases with the increase in the number of FeSiB layers. When the surface crystalline FeSiB ribbons are combined with a commercially available hard piezoelectric ceramic plate, the maximum magnetoelectric coupling coefficient of the ME composite reaches 5522 V/(Oe*cm), of which the electromechanical resonant frequency is 23.89 kHz.

13.
Gels ; 9(11)2023 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-37998963

RESUMO

Chromium (Cr)-doped cobalt ferrite nanoparticles were synthesized using a sol-gel autocombustion method, with the chemical formula CoCrxFe2xO4. The value of x ranged from 0.00 to 0.5 in 0.1 increments. X-ray diffraction analysis confirmed the development of highly crystalline cubic spinel structures for all samples, with an average crystallite size of approximately 40 to 45 nm determined using the Scherrer equation. Pellets were prepared using a traditional ceramic method. The magnetic and magnetostrictive properties of the samples were tested using strain gauge and VSM (vibrating sample magnetometer) techniques. The results of the magnetic and magnetostrictive tests showed that the chromium-substituted cobalt ferrites exhibited higher strain derivative magnitudes than pure cobalt ferrite. These findings indicated that the introduction of chromium into the cobalt ferrite structure led to changes in the material's magnetic properties. These changes were attributed to anisotropic contributions, resulting from an increased presence of Co2+ ions at B-sites due to the chromium substitutions. In summary, this study concluded that introducing chromium into the cobalt ferrite structure caused alterations in the material's magnetic properties, which were explained by changes in the cationic arrangement within the crystal lattice. This study successfully explained these alterations using magnetization and coercivity data and the probable cationic dispersion.

14.
Sensors (Basel) ; 23(20)2023 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-37896719

RESUMO

Magnetoelectric (ME)-based magnetometers have garnered much attention as they boast ultra-low-power systems with a small form factor and limit of detection in the tens of picotesla. The highly sensitive and low-power electric readout from the ME sensor makes them attractive for near DC and low-frequency AC magnetic fields as platforms for continuous magnetic signature monitoring. Among multiple configurations of the current ME magnetic sensors, most rely on exploiting the mechanically resonant characteristics of a released ME microelectromechanical system (MEMS) in a heterostructure device. Through optimizing the resonant device configuration, we design and fabricate a fixed-fixed resonant beam structure with high isolation compared to previous designs operating at ~800 nW of power comprised of piezoelectric aluminum nitride (AlN) and magnetostrictive (Co1-xFex)-based thin films that are less susceptible to vibration while providing similar characteristics to ME-MEMS cantilever devices. In this new design of double-clamped magnetoelectric MEMS resonators, we have also utilized thin films of a new iron-cobalt-hafnium alloy (Fe0.5Co0.5)0.92Hf0.08 that provides a low-stress, high magnetostrictive material with an amorphous crystalline structure and ultra-low magnetocrystalline anisotropy. Together, the improvements of this sensor design yield a magnetic field sensitivity of 125 Hz/mT when released in a compressive state. The overall detection limit of these sensors using an electric field drive and readout are presented, and noise sources are discussed. Based on these results, design parameters for future ME MEMS field sensors are discussed.

15.
Sensors (Basel) ; 23(13)2023 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-37447750

RESUMO

Magnetic field sensors using magnetoelectric (ME) effects in planar ferromagnetic-piezoelectric heterostructures convert a magnetic field into an output voltage. The parameters of ME sensors are determined by characteristics of the magnetic constituent. In this work, the low-frequency ME effects in heterostructures comprising a layer of antiferromagnetic hematite α-Fe2O3 crystal with easy-plane anisotropy and a piezoelectric layer are studied. The effects arise due to a combination of magnetostriction and piezoelectricity because of mechanical coupling of the layers. The field dependences of magnetization and magnetostriction of the hematite crystal are measured. The resonant ME effects in the hematite-piezopolymer and hematite-piezoceramic structures are studied. The strong coupling between magnetic and acoustic subsystems of hematite results in a tuning of the acoustic resonance frequency by the magnetic field. For the hematite layer, the frequency tuning was found to be ~37% with an increase in the bias field up to 600 Oe. For the hematite-PVDF heterostructure, the frequency tuning reached ~24% and the ME coefficient was 58 mV/(Oe∙cm). For the hematite-piezoceramic heterostructure, the frequency tuning was ~4.4% and the ME coefficient 4.8 V/(Oe∙cm). Efficient generation of the second voltage harmonic in the hematite-piezoceramic heterostructure was observed.


Assuntos
Acústica , Campos Magnéticos , Anisotropia , Imãs
16.
Sensors (Basel) ; 23(13)2023 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-37447775

RESUMO

As is well known, the magnetostrictive phenomenon of electrical steel sheet is the main source of electricity in equipment such as transformers. The magnetostrictive characteristic of the actual transformer core is more complicated than that of single-sheet steel. The magnetostriction phenomenon of the transformer core cannot be fully understood by studying only a single piece of electrical steel, so it is necessary to study the local magnetic characteristics of the transformer directly. In this paper, two-limb, one-phase transformer core with a multi-step-lap construction was assembled, a laminated magnetostrictive testing system based on triaxial strain gauges was built, and the local magnetic characteristics were studied using a self-developed B-H vector sensor. The magnetostrictive and magnetic properties in different local regions were measured and analyzed under several magnetization patterns, and the influence of DC bias on the magnetostrictive property of the corner, yoke, and limb of the core was investigated. The influence of the position of the clamp on the magnetostriction of the transformer core was also studied. The magnetostrictive strain of the single sheet and laminated core was compared and discussed. The results showed that the strain caused by the interaction between laminations in this area can be effectively reduced when clamping in the middle of the yoke.


Assuntos
Fontes de Energia Elétrica , Eletricidade , Extremidades , Fenômenos Físicos , Aço
17.
Micromachines (Basel) ; 14(4)2023 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-37421000

RESUMO

Magnetorheological elastomer (MRE), which is capable of exhibiting magnetostriction in the presence of a magnetic field, has a great potential to be used for the development of sensor devices. Unfortunately, to date, many works focused on studying low modulus of MRE (less than 100 kPa) which can hamper their potential application in sensors due to short lifespan and low durability. Thus, in this work, MRE with storage modulus above 300 kPa is to be developed to enhance magnetostriction magnitude and reaction force (normal force). To achieve this goal, MREs are prepared with various compositions of carbonyl iron particles (CIPs), in particular, MRE with 60, 70 and 80 wt.% of CIP. It is shown that both the magnetostriction percentage and normal force increment are achieved as the concentration of CIPs increases. The highest magnetostriction magnitude of 0.075% is obtained with 80 wt.% of CIP, and this increment is higher than that of moderate stiffness MRE developed in the previous works. Therefore, the midrange range modulus MRE developed in this work can copiously produce the required magnetostriction value and potentially be implemented for the design of forefront sensor technology.

18.
Materials (Basel) ; 16(6)2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36984245

RESUMO

Fe-Ga alloys (GalFeNOLs) are the focus of attention due to their enhanced magneto-elastic properties, namely, magnetostriction in low saturation magnetic fields. In the last several years, special attention has been paid to the anelastic properties of these alloys. In this review, we collected and analyzed the frequency-, amplitude-, and temperature-dependent anelasticity in Fe-Ga and Fe-Ga-based alloys in the Hertz range of forced and free-decay vibrations. Special attention is paid to anelasticity caused by phase transitions: for this purpose, in situ neutron diffraction tests with the same heating or cooling rates were carried out in parallel with temperature dependencies measurements to control ctructure and phase transitions. The main part of this review is devoted to anelastic effects in binary Fe-Ga alloys, but we also consider ternary alloys of the systems Fe-Ga-Al and Fe-Ga-RE (RE-Rare Earth elements) to discuss similarities and differences between anelastic properties in Fe-Ga and Fe-Al alloys and effect of RE elements. We report and discuss several thermally activated effects, including Zener- and Snoek-type relaxation, several transient anelastic phenomena caused by phase transitions (D03 ↔ A2, D03 → L12, L12 ↔ D019, D019 ↔ B2, Fe13Ga9 → L12+Fe6Ga5 phases), and their influence on the above-mentioned thermally activated effects. We also report amplitude-dependent damping caused by dislocations and magnetic domain walls and try to understand the paradox between the Smith-Birchak model predicting higher damping capacity for materials with higher saturation magnetostriction and existing experimental results. The main attention in this review is paid to alloys with 17-20 and 25-30%Ga as the alloys with the best functional (magnetostriction) properties. Nevertheless, we provide information on a broader range of alloys from 6 to 45%Ga. Due to the limited space, we do not discuss other mechanical and physical properties in depth but focus on anelasticity. A short introduction to the theory of anelasticity precedes the main part of this review of anelastic effects in Fe-Ga and related alloys and unsolved issues are collected in summary.

19.
ACS Appl Mater Interfaces ; 15(12): 15691-15706, 2023 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-36939288

RESUMO

This work reports on the effect of substituting a low-anisotropic and low-magnetic cation (Ni2+, 2µB) by a high-anisotropic and high-magnetic cation (Co2+, 3µB) on the crystal structure, phase, microstructure, magnetic properties, and magnetostrictive properties of NiFe2O4 (NFO). Co-substituted NFO (Ni1-xCoxFe2O4, NCFO, 0 ≤ x ≤ 1) nanomaterials were synthesized using glycine-nitrate autocombustion followed by postsynthesis annealing at 1200 °C. The X-ray diffraction measurements coupled with Rietveld refinement analyses indicate the significant effect of Co-substitution for Ni, where the lattice constant (a) exhibits a functional dependence on composition (x). The a-value increases from 8.3268 to 8.3751 Å (±0.0002 Å) with increasing the "x" value from 0 to 1 in NCFO. The a-x functional dependence is derived from the ionic-size difference between Co2+ and Ni2+, which also induces grain agglomeration, as evidenced in electron microscopy imaging. The chemical bonding of NCFO, as probed by Raman spectroscopy, reveals that Co(x)-substitution induced a red shift of the T2g(2) and A1g(1) modes, and it is attributed to the changes in the metal-oxygen bond length in the octahedral and tetrahedral sites in NCFO. X-ray photoelectron spectroscopy confirms the presence of Co2+, Ni2+, and Fe3+ chemical states in addition to the cation distribution upon Co-substitution in NFO. Chemical homogeneity and uniform distribution of Co, Ni, Fe, and O are confirmed by EDS. The magnetic parameters, saturation magnetization (MS), remnant magnetization (Mr), coercivity (HC), and anisotropy constant (K1) increased with increasing Co-content "x" in NCFO. The magnetostriction (λ) also follows a similar behavior and almost linearly varies from -33 ppm (x = 0) to -227 ppm (x = 1), which is primarily due to the high magnetocrystalline anisotropy contribution from Co2+ ions at the octahedral sites. The magnetic and magnetostriction measurements and analyses indicate the potential of NCFO for torque sensor applications. Efforts to optimize materials for sensor applications indicate that, among all of the NCFO materials, Co-substitution with x = 0.5 demonstrates high strain sensitivity (-2.3 × 10-9 m/A), which is nearly 2.5 times higher than that obtained for their intrinsic counterparts, namely, NiFe2O4 (x = 0) and CoFe2O4 (x = 1).

20.
Photoacoustics ; 30: 100463, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36874592

RESUMO

Using time-resolved x-ray diffraction, we demonstrate the manipulation of the picosecond strain response of a metallic heterostructure consisting of a dysprosium (Dy) transducer and a niobium (Nb) detection layer by an external magnetic field. We utilize the first-order ferromagnetic-antiferromagnetic phase transition of the Dy layer, which provides an additional large contractive stress upon laser excitation compared to its zero-field response. This enhances the laser-induced contraction of the transducer and changes the shape of the picosecond strain pulses driven in Dy and detected within the buried Nb layer. Based on our experiment with rare-earth metals we discuss required properties for functional transducers, which may allow for novel field-control of the emitted picosecond strain pulses.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA