1.
Front Bioeng Biotechnol ; 12: 1368383, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38600944

RESUMO

Material properties of soft-tissue samples are often derived through uniaxial tensile testing. For engineering materials, testing parameters (e.g., sample geometries and clamping conditions) are described by international standards; for biological tissues, such standards do not exist. To investigate what testing parameters have been reported for tensile testing of human soft-tissue samples, a systematic review of the literature was performed using PRISMA guidelines. Soft tissues are described as anisotropic and/or hyperelastic. Thus, we explored how the retrieved parameters compared against standards for engineering materials of similar characteristics. All research articles published in English, with an Abstract, and before 1 January 2023 were retrieved from databases of PubMed, Web of Science, and BASE. After screening of articles based on search terms and exclusion criteria, a total 1,096 articles were assessed for eligibility, from which 361 studies were retrieved and included in this review. We found that a non-tapered shape is most common (209 of 361), followed by a tapered sample shape (92 of 361). However, clamping conditions varied and were underreported (156 of 361). As a preliminary attempt to explore how the retrieved parameters might influence the stress distribution under tensile loading, a pilot study was performed using finite element analysis (FEA) and constitutive modeling for a clamped sample of little or no fiber dispersion. The preliminary FE simulation results might suggest the hypothesis that different sample geometries could have a profound influence on the stress-distribution under tensile loading. However, no conclusions can be drawn from these simulations, and future studies should involve exploring different sample geometries under different computational models and sample parameters (such as fiber dispersion and clamping effects). Taken together, reporting and choice of testing parameters remain as challenges, and as such, recommendations towards standard reporting of uniaxial tensile testing parameters for human soft tissues are proposed.

2.
Dent J (Basel) ; 12(4)2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38668018

RESUMO

This study aimed to examine how heating affects the physical properties of a newly developed premixed calcium silicate-containing sealer (AH Plus Bioceramic Sealer; AHB), in comparison with EndoSequence BC Sealer (ES), AH Plus Jet (AH), and Pulp Canal Sealer. The setting time, flow, and film thickness were tested with or without heating at 100 °C for 30 or 60 s, in accordance with ISO6876:2012 standards. Ultrastructural and elemental analyses were performed with scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS). Data were analyzed using one-way analysis of variance (ANOVA) with a Tukey post hoc test (α = 0.05). All sealers exhibited significantly shorter setting time and flow after heating at 100 °C for 30 and 60 s (p < 0.05). After heating, AHB showed a significantly higher film thickness compared to that of the other materials (p < 0.05). None of the tested properties of heat-applied AHB and ES met ISO standards, except the setting time in ES. The SEM/EDS results for AHB and ES were not affected by heating. The detected changes in physical properties can negatively impact the performance of premixed calcium silicate-containing sealers, particularly AHB, when warm vertical compaction is employed.

3.
Biomedicines ; 12(4)2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38672223

RESUMO

To date, studies assessing the safety profile of 3D printing materials for application in cardiac ablation are sparse. Our aim is to evaluate the safety and feasibility of two biocompatible 3D printing materials, investigating their potential use for intra-procedural guides to navigate surgical cardiac arrhythmia ablation. Herein, we 3D printed various prototypes in varying thicknesses (0.8 mm-3 mm) using a resin (MED625FLX) and a thermoplastic polyurethane elastomer (TPU95A). Geometrical testing was performed to assess the material properties pre- and post-sterilization. Furthermore, we investigated the thermal propagation behavior beneath the 3D printing materials during cryo-energy and radiofrequency ablation using an in vitro wet-lab setup. Moreover, electron microscopy and Raman spectroscopy were performed on biological tissue that had been exposed to the 3D printing materials to assess microparticle release. Post-sterilization assessments revealed that MED625FLX at thicknesses of 1 mm, 2.5 mm, and 3 mm, along with TPU95A at 1 mm and 2.5 mm, maintained geometrical integrity. Thermal analysis revealed that material type, energy source, and their factorial combination with distance from the energy source significantly influenced the temperatures beneath the 3D-printed material. Electron microscopy revealed traces of nitrogen and sulfur underneath the MED625FLX prints (1 mm, 2.5 mm) after cryo-ablation exposure. The other samples were uncontaminated. While Raman spectroscopy did not detect material release, further research is warranted to better understand these findings for application in clinical settings.

4.
Materials (Basel) ; 17(3)2024 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-38591603

RESUMO

This work was dedicated to the simulation of fiber composite structures consisting of carbon fibers and mineral impregnation. The aim of this study was to generate a micromodel that predicts the properties of a mineral-impregnated carbon fiber reinforcement. The numerical characterization was based on the discrete microscopic modeling of the individual phases using a representative volume element. In addition, the stochastic nature of the fiber strength, the anisotropic damage mechanisms of the brittle matrix, and the non-linear bonding behavior between the filaments and the matrix were considered in the material models. The material models were adjusted based on the literature sources and our own experimental investigations. This was followed by the validation of the representative volume element, quantifying the evolution of stiffness and damage under longitudinal tensile loading. The numerical results of material stiffness, as well as the tensile strength of the representative volume element, were compared with the results of the experimental investigations. To verify the robustness of the numerical model, significant model parameters were subjected to a sensitivity analysis.

5.
Polymers (Basel) ; 16(3)2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38337290

RESUMO

Reducing the CO2 emissions of plastic parts is crucial in terms of sustainable product and process designs. Approaches include the use of recycled materials and reducing the energy demands of processes through more efficient technologies. In this context, this study shows the potential of the steam-free processing of particle foam beads into thin-walled moulded parts. Expanded polypropylene (EPP) particle foam beads have been processed in both a steam-free and steam-based process. For this purpose, specimens with different part densities and thicknesses were produced, the mechanical properties were investigated, and the surface quality was discussed. Specimens made of EPP with a part thickness of 5 to 20 mm and part densities of 60 to 185 g/L were produced steam-free. Lower part thicknesses and higher densities increase the mechanical properties. As the density increased, the homogeneity of the surfaces of the steam-free specimens also increased. In comparison, specimens with a thickness of 10 mm and part densities of 35 to 90 g/L were produced on a steam-based process. The results of the mechanical test were compared with those of the steam-free specimens. The steam-based specimens showed higher mechanical properties for the same density.

6.
Med Devices (Auckl) ; 17: 23-36, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38196508

RESUMO

Introduction: Common in vitro cell culture systems for testing implant material immune compatibility either rely on immortal human leukocyte cell lines or isolated primary cells. Compared to in vivo conditions, this generates an environment of substantially reduced complexity, often lacking important immune cell types, such as neutrophil granulocytes and others. The aim of this study was to establish a reliable test system for in vitro testing of implant materials under in vivo-like conditions. Methods: Test materials were incubated in closed, CO2-independent, tube-based culture vessels containing a proprietary cell culture medium and human whole blood in either a static or occasionally rotating system. Multiplex cytokine analysis was used to analyze immune cell reactions. Results: To demonstrate the applicability of the test system to implant materials, three commercially available barrier membranes (polytetrafluoroethylene (PTFE), polycaprolactone (PCL) and collagen) used for dental, trauma and maxillofacial surgery, were investigated for their potential interactions with immune cells. The results showed characteristic differences between the static and rotated incubation methods and in the overall activity profiles with very low immune cell responses to PTFE, intermediate ones to collagen and strong reactions to PCL. Conclusion: This in vitro human whole blood model, using a complex organotypic matrix, is an excellent, easily standardized tool for categorizing immune cell responses to implant materials. Compared to in vitro cell culture systems used for materials research, this new assay system provides a far more detailed picture of response patterns the immune system can develop when interacting with different types of materials and surfaces.

7.
Sensors (Basel) ; 23(22)2023 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-38005601

RESUMO

Polymers find widespread applications in various industries, such as civil engineering, aerospace, and industrial machinery, contributing to vibration control, dampening, and insulation. To accurately design products that are able to predict their dynamic behavior in the virtual environment, it is essential to understand and reproduce their viscoelastic properties via material physical modeling. While Dynamic Mechanical Analysis (DMA) has traditionally been used, innovative non-destructive techniques are emerging for characterizing components and monitoring their performance without deconstructing them. In this context, the Time-Temperature Superposition Principle (TTSP) represents a powerful empirical procedure to extend a polymer's viscoelastic behavior across a wider frequency range. This study focuses on replicating an indentation test on viscoelastic materials using the non-destructive Viscoelasticity Evaluation System evolved (VESevo) tool. The primary objective is to derive a unique temperature-frequency relationship, referred to as a "shift law", using characteristic curves from this non-invasive approach. Encouragingly, modifying the device setup enabled us to replicate, virtually, three tests under identical initial conditions but with varying indentation frequencies. This highlights the tool's ability to conduct material testing across a range of frequencies. These findings set the stage for our upcoming experiment campaign, aiming to create an innovative shift algorithm from at least three distinct master curves at specific frequencies, offering a significant breakthrough in non-destructive polymer characterization with broad industrial potential.

8.
Materials (Basel) ; 16(22)2023 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-38005146

RESUMO

In this study, rigid polyurethane foams modified with non-halogenated flame retardant were obtained. The foams were synthesized using two systems containing different blowing agents. In the first one, cyclopentane and water were used as a mixture of blowing agents, and in the second one, only water was used as a chemical blowing agent. The systems were modified with the additive phosphorus flame retardant Roflam F5. The obtained modified foams were tested for their flammability and basic properties, such as apparent density, closed-cell contents and analyses of the cell structures, thermal conductivity, mechanical properties, and water absorption. Increasing the content of Roflam F5 caused a decrease in temperature during the combustion of the material and extended the burning time. The addition of 1.0 wt.% phosphorus derived from Roflam F5 caused the modified rigid polyurethane foam to become a self-extinguishing material. The increase in the content of Roflam F5 caused a decrease in the total heat release and the maximum heat release rate during the pyrolysis combustion flow calorimetry. The foams with the highest content of flame retardant and foamed with a chemical-physical and chemical blowing agent had a lower total heat release by 19% and 11%, respectively, compared to reference foams.

9.
Sensors (Basel) ; 23(21)2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37960583

RESUMO

In construction, ensuring the quality and compliance of materials with specified requirements is often challenging, especially at construction sites. Conventionally, this process necessitates transporting samples to well-equipped laboratories, incurring significant time and financial costs. This article proposes a novel approach through a cost-effective mobile test station, enabling on-site measurements and immediate evaluation results, regardless of the testing conditions. The foundation of our testing methodology lies in the Impulse Excitation Technique (IET), which capitalises on measuring the frequency response of samples while considering their mass and dimensions. By applying this technique, we can effectively determine crucial elastic properties, such as the Young Modulus and Poisson Ratio. These obtained values can then be cross-referenced with established material tables to verify the material's compliance with the specified order. In this study, the developed universal and mobile test station demonstrated versatility by successfully evaluating three samples of typical construction materials, showing the method's reliability on some real case measurements. The results substantiate its potential as a reliable mobile quality assurance station. Moreover, the station's adaptability empowers its use on site, in laboratory settings, or even during material transportation when necessary. This innovation promises to revolutionise material quality assessment, streamlining the construction process and expediting decision making.

10.
Dent Med Probl ; 60(3): 413-420, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37796047

RESUMO

BACKGROUND: Elastomeric chains promote controlled movements and are widely used in orthodontics. OBJECTIVES: The aim of the study was to evaluate the force decay and elongation of orthodontic chains exposed to low-pH saliva (pH = 4) and different beverages common in the diet. MATERIAL AND METHODS: Force decay and elongation were determined in vitro at 6 time intervals over 21 days for 2 commercial elastomeric chains - Ormco (group A) and Borgatta (group B). The samples were immersed in artificial saliva (AS) at pH 4, Coca-Cola®, coffee, or beer for 15 min every day, or in AS (the control group). For the remaining time, the chains were placed into AS at 37°C. In addition, microscopic qualitative changes were recorded by means of scanning electron microscopy (SEM). RESULTS: The group B chains showed higher force decay and elongation at the end of the follow-up as compared to the group A chains. Exposure to beer had a greater impact on the force decay and elongation of the chains as compared to other liquids, but it was not statistically significant. The group A chains showed a more irregular surface than the group B chains, in particular, those exposed to coffee. CONCLUSIONS: Elastomeric chains suffer force decay and elongation as a function of time, mainly in the first 24 h. At the end of the follow-up, the group A chains exhibited less force decay in comparison with the group B chains. The qualitative observations showed that the chains in group A had a more irregular surface than the chains in group B.


Assuntos
Café , Elastômeros , Humanos , Aparelhos Ortodônticos , Elasticidade , Saliva Artificial , Dieta
11.
Materials (Basel) ; 16(17)2023 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-37687618

RESUMO

Bracing has proven to be an effective method for the conventional treatment of scoliosis in young people. A brace, a therapeutic device, covers the upper body and promotes healing by applying pressure to specific areas. However, wearing a scoliosis brace negatively affects the user's thermo-physiological well-being and often leads to discomfort. In this study, we investigated the influence of T-shirts as an undergarment on the thermo-physiological well-being of the brace wearer. For this purpose, we performed a comparative analysis of six T-shirts made from different special knitted fabrics. We carried out wearing tests in a computer-controlled climate chamber according to a predetermined protocol. The test subject wore the orthopedic brace over the different T-shirts at three different temperatures. The results indicate that the knitted fabrics of undergarments and environmental conditions considerably impact the wearer's thermo-physiological comfort. In the tests, the T-shirts made from the selected functional fabrics performed very well. The T-shirt made from the classic cotton fabric containing elastane yarn also performed well and was the most environmentally friendly. Currently, due to its lower price and easier availability, this cotton T-shirt can be recommended for wearing under a scoliosis brace.

12.
HardwareX ; 16: e00475, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37771321

RESUMO

Accurate material characterization of soft tissues is crucial for understanding the physiopathology of cardiovascular diseases. However, commercial biaxial testing systems are expensive, prompting the need for affordable custom solutions. This study aimed to develop a low-cost custom biaxial system capable of accurately characterizing the mechanical behavior of soft tissues. The biaxial system was constructed using 3D printing technology and non-captive linear actuators for precise displacement control. A real-time marker tracking system was implemented to estimate dis-placements without the need for costly hardware. The system's performance was evaluated through tests on a calibration spring and frozen porcine aorta samples. The linear actuators demonstrated excellent response to user position input after motor tuning, showing no discrepancies between commands and actual positions. The experimental testing of the calibration spring showed good agreement with the analytical solution, validating the system's ability to accurately test materials. Testing on porcine aorta samples revealed stress-strain responses consistent with existing literature, accounting for potential variations due to tissue preservation and regional material property heterogeneity. Overall, this custom biaxial system demonstrates promising performance in accurately assessing the mechanical behavior of soft tissues, providing researchers with a valuable tool for cardiovascular disease research and tissue engineering applications.

13.
Clin Oral Implants Res ; 34(11): 1217-1229, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37565379

RESUMO

OBJECTIVE: To analyze the influence of titanium-base (straight [SSC]/angulated-screw-channel [ASC]) on failure-loads and bending-moments of two-piece ceramic and titanium-zirconium implants restored with monolithic-zirconia crowns after fatigue. MATERIALS AND METHODS: Thirty-two anterior monolithic-screw-retained zirconia crowns were divided into four groups (n = 8/group) according to the factors: (1) type of implant material: two-piece titanium-zirconium implant (Ti-Zr; control-group) versus two-piece ceramic implant (CI; test-group) and (2) type of titanium-base: SSC (0° angle) versus ASC (25°). An intact implant was used for field emission gun-scanning electronic microscopy (FEG-SEM) characterization and Raman spectroscopy for phase analyses and residual stress quantification. All samples were exposed to fatigue with thermodynamic loading (1.2-million-cycles, 49 N, 1.6 Hz, 5-55°C) at a 30° angle. Surviving specimens were loaded until failure (SLF) and bending moments were recorded. Failed samples were examined using light microscope and SEM. Statistical analyses included ANOVA and Mann-Whitney U-test. RESULTS: Raman-spectroscopy revealed the presence of residual compressive stresses. FEG-SEM revealed a roughened surface between threads and polished surface at the cervical-collar of the ceramic implant. All samples survived fatigue and were free of complications. Mean bending-moments (±SD) were: Ti-Zr-0: 241 ± 45 N cm, Ti-Zr-25: 303 ± 86 N cm, CI-0: 326 ± 58 N cm, CI-25: 434 ± 71 N cm. Titanium-base and implant-material had significant effects in favor of ASC titanium bases (p = .001) and ceramic-implants (p < .001). Failure analysis after SLF revealed severe fractures in ceramic implants, whereas titanium implants were restricted to plastic deformation. CONCLUSIONS: Ceramic and titanium implants exhibited high reliability after fatigue, with no failures. From a mechanical perspective, titanium bases with ASC can be recommended for both ceramic and titanium implants and are safe for clinical application.


Assuntos
Implantes Dentários , Zircônio , Zircônio/química , Titânio/química , Reprodutibilidade dos Testes , Teste de Materiais , Dente Suporte , Projeto do Implante Dentário-Pivô , Falha de Restauração Dentária , Cerâmica/química , Coroas , Parafusos Ósseos
14.
Sensors (Basel) ; 23(12)2023 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-37420804

RESUMO

The Impulse Excitation Technique (IET) is one of the most useful testing methods for evaluating or calculating some material properties. This can be useful to evaluate and confirm that the material ordered is what was delivered. In the case of unknown materials, where their properties are required by simulation software, this is also a quick way to obtain mechanical properties and thus improve the simulation quality. The main drawback of the method is the requirement for a specialized sensor and acquisition system and a well-trained engineer to prepare the setup and analyze the results. The article evaluates the possibility of using a low-cost solution in the form of a mobile device microphone as a way to obtain data, which after the Fast Fourier Transform (FFT), allows to obtain frequency response graphs and use the IET method procedure to calculate the mechanical properties of the samples. The data obtained by the mobile device are compared with the data obtained by professional sensors and data acquisition systems. The results confirm that for typical homogenous materials, the mobile phone is a cheap and reliable alternative for fast, on-the-go material quality inspections and can be introduced even in small companies and on construction sites. Additionally, this kind of approach does not require specific knowledge of sensing technology, signal treatment, or data analysis and can be performed by any assigned employee, who can receive the quality check information immediately on-site. Additionally, the presented procedure allows data collection and transfer to the cloud for future references and additional information extraction. This element is fundamental for introducing sensing technologies under the Industry 4.0 concept.


Assuntos
Telefone Celular , Computadores de Mão , Software , Previsões , Simulação por Computador
15.
Clin Oral Investig ; 27(5): 2221-2234, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36977761

RESUMO

OBJECTIVES: To evaluate the biocompatibility, physical and chemical properties of three pre-mixed calcium silicate-based sealers and an epoxy resin-based material were assessed. Pre-mixed sealers supposedly obtain water from the root canal moist to hydrate and set. MATERIALS AND METHODS: Polyethylene tubes were filled with the materials Bio-C Sealer Ion+, Bio-C Sealer, EndoSequence BC Sealer and AH Plus Jet, or left empty and surgically implanted in the subcutaneous tissue of Wistar rats. The animals were euthanised and the tubes and tissue were removed for histological analysis and scanning electron microscopy (SEM) coupled with energy-dispersive spectrometry (EDS). Materials' surface chemical characterisation was assessed using Raman spectroscopy and SEM/EDS. Flow, setting time (in two conditions), solubility, radiopacity and pH were also analysed. ANOVA and Bonferroni correction were performed for comparisons (P < 0.05). RESULTS: Inflammatory response observed in the tissues subsided from 7 to 30 days. Tungsten migration could be detected in the surrounding tissue following AH Plus Jet implantation. All calcium silicate-based sealers exhibited zirconium oxide (radiopacifier) and tricalcium silicate peaks before and after implantation. All materials exhibited flow values above 17 mm. An approximately tenfold difference was observed between the plaster- and metal-mould setting times of the calcium silicate cements indicating its sensitivity to moist variations and solubility above 8% was also observed for these materials. CONCLUSIONS: Pre-mixed materials exhibited variable setting time and solubility with a decreasing inflammatory response. CLINICAL RELEVANCE: The variable moist-dependant setting time with high solubility poses a concern for the clinical use of these pre-mixed sealers.


Assuntos
Materiais Restauradores do Canal Radicular , Ratos , Animais , Materiais Restauradores do Canal Radicular/farmacologia , Materiais Restauradores do Canal Radicular/química , Tela Subcutânea , Ratos Wistar , Cromatografia Gasosa-Espectrometria de Massas , Compostos de Cálcio/química , Resinas Epóxi/química , Silicatos/química , Teste de Materiais
16.
Orthopadie (Heidelb) ; 52(3): 186-195, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36853395

RESUMO

The success of hip arthroplasty is based on modern materials in addition to the continuous development of surgical techniques and clinical experience gained over six decades. The biocompatible implant materials used in hip arthroplasty can be textured or coated with biomimetic surfaces to ensure durable component ingrowth and moderate host response. Material integrity plays a critical role in the durability of the stable interface between implant components and periprosthetic tissues. Inflammation at the interfaces due to the release of degradation products from the implant materials is one of the causes of hip arthroplasty failure. This review summarizes the implant materials currently used in hip arthroplasty, their preclinical testing and the postoperative neogenesis of periprosthetic tissues, and the interactions of periprosthetic bone and the implant materials at the periprosthetic interfaces.


Assuntos
Artroplastia de Quadril , Artroplastia de Quadril/efeitos adversos , Materiais Biocompatíveis , Próteses e Implantes , Articulações
17.
Polymers (Basel) ; 14(21)2022 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-36365482

RESUMO

Class II malocclusion is one of the most common dental anomalies and the use of intermaxillary elastomers is the standard method in its treatment. However, orthodontic elastics cannot exert continuous force over a period of time due to force degradation. Our goal was to mechanically characterize the different types of elastomers during static and cyclic loads, based on uniform methodology and examine the morphological changes after loading. Ten types of latex-containing and four latex-free intermaxillary elastics were examined from six different manufacturers. To determine the mechanical characteristics of the elastomers, tensile tests, cyclical tensile fatigue tests and 24 h relaxation tests were performed, and the elastics were also subjected to scanning electron microscopy (SEM) and Raman spectroscopy. Regardless of the manufacturer, the latex-containing elastomers did not show significant differences in the percentage of elongation at break during the tensile test. Only one type of latex-containing elastomer did not tear during the 24 h cyclical fatigue test. Fatigue was confirmed by electron microscopy images, and the pulling force reduced significantly. During the force relaxation test, only one latex-free ligature was torn; the force degradation was between 7.8% and 20.3% for latex ligatures and between 29.6% and 40.1% for latex-free elastomers. The results showed that dynamic loading was more damaging to ligatures than static loading, latex-containing elastomers were more resistant than latex-free elastics, and which observation could have clinical consequences or a potential effect on patient outcome.

18.
HardwareX ; 12: e00349, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36065361

RESUMO

Mechanoluminescent materials transform mechanical energy into visible light. Phenomena could prove to be advantageous to various next-generation monitoring systems employed in the fields of security and healthcare if the intrinsic mechanisms are fully understood. Scientific efforts are mainly hindered by the lack of equipment capable of controlled mechanical deformation and simultaneous collection of light emitted by the sample. This article describes an easily constructible material testing device (508 €) with an interchangeable test fixture and an integrated load cell made from readily available mechanical components and 3D printed parts. A commercial low-cost alternative to spectroscopic apparatus (200 €) has recently become available alongside a highly capable 16-bit CMOS camera intended for low light conditions (520 €). A highly modular prototype system with an overall cost much lower than commercial alternatives that provide less functionality could enable a larger portion of scientific personnel to contribute to a novel field of research.

19.
Materials (Basel) ; 15(18)2022 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-36143784

RESUMO

The paper presents a literature review on the development of microvoids in metals, leading to ductile fracture associated with plastic deformation, without taking into account the cleavage mechanism. Particular emphasis was placed on the results of observations and experimental studies of the characteristics of the phenomenon itself, without in-depth analysis in the field of widely used FEM modelling. The mechanism of void development as a fracture mechanism is presented. Observations of the nucleation of voids in metals from the turn of the 1950s and 1960s to the present day were described. The nucleation mechanisms related to the defects of the crystal lattice as well as those resulting from the presence of second-phase particles were characterised. Observations of the growth and coalescence of voids were presented, along with the basic models of both phenomena. The modern research methods used to analyse changes in the microstructure of the material during plastic deformation are discussed. In summary, it was indicated that understanding the microstructural phenomena occurring in deformed material enables the engineering of the modelling of plastic fracture in metals.

20.
Materials (Basel) ; 15(16)2022 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-36013710

RESUMO

For surgical catheterization training applications, realistic and effective materials are desired. In this study, the relevance of a needle puncture angle and a simulated wall stress on different elastic materials were determined in a previously developed experimental setup. Both settings were considered individually in two new setups. In addition, a control setup with neither angle nor prestress was designed. During the process of puncturing the samples of two materials (Replisil 9N and Formlabs Elastic 50A), force−displacement values were collected, and three predefined parameters evaluated. The differences between the angled/stressed groups and the control group were analyzed. The additively processed material required a significantly higher force to puncture than the conventional one (p < 0.001). Moreover, a needle angulation of 45° required more force than puncturing orthogonally. Prestressing the samples did not clearly influence the resulting force. An evaluation of relative parameters showed that the investigated materials behaved differently but not linearly differently under the influence of needle angle and prestress. Therefore, it is essential to evaluate the properties and suitability of materials for surgical training models in appropriate experimental setups considering multiple parameters.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...